You are on page 1of 5

Aiken, I., Nims, D., Whittaker, A. y Kelly, J. (1993). Testing of Passive Energy Dissipation Systems. Eartquake Spectra, Vol.

9, N 3. Butterworth, J.W. (1999). Seismic Response of Steel Frames Containing Hierarchical Friction-Dissipating Joints, Mechanics of Structures and Materials, Bradford, Bridge & Foster (eds), Balkema, Rotterdam, 551-556. Butterworth, J. W., & Clifton, C. G. (2000). Performance of hierarchical friction dissipating joints in moment resisting steel frames. In Proceedings of 12th World Conference on Earthquake Engineering. Chan, Ricky WK, Faris Albermani, and Martin S. Williams. (2009). "Evaluation of yielding shear panel device for passive energy dissipation." Journal of Constructional Steel Research. Chan, Ricky WK, and Faris Albermani. (2008). "Experimental study of steel slit damper for passive energy dissipation." Engineering Structures. Constantinou, M. C., Soong, T. T., & Dargush, G. F. (1998). Passive energy dissipation systems for structural design and retrofit. Bu ffalo, NY: Multidisciplinary Center for Earthquake Engineering Research. Elenas, A., and D. Tzourmakliotou. (2008). "Influence of friction devices on the nonlinear seismic response of steel structures." Habibi, Ali, Ricky WK Chan, and Faris Albermani. (2013). "Energy-based design method for seismic retrofitting with passive energy dissipation systems."Engineering Structures. Hanson, R.D. and Soong, T.T. (2001). Seismic Design with Supplemental Energy Dissipation Devices, Monograph Series 8, EERI, Oakland, California. Hanson, R. D., Aiken, I., Nims, D.K., Richter, P.J., and Bachman, R., (1993). State of-the-art anda sate of the practice in seiemic energy dissipation, ATC-17-1 seminar on seiemic isolation, passive energy dissipation, and active control, san francisco, CA, 449-471. Ken, I. D, Nims, D. K., and Kelly, J. M. (1992), "Comparative Study of Four Passive Energy Dissipation Systems", Bulletin of the New Zealand National Society for Earthquake Engineering, Vol. 25., No. 3. New Zealand. Kasai, K., Fu, Y., and Watanabe, A., (1998). "Passive Control Systems for Seismic Damage Mitigation," Journal of Structural Engineering. Niwa, N., Kobori, T., Takahasi, M., Hatada, T., and Kurino, H., (1995). "Passive Seismic Response Controlled High-Rise Building with High Damping Device,"Earthquake Engineering and Structural Dynamics. Palazzo, Gustavo Luis, and Francisco Javier Crisafulli. (2011). "Evaluacin de la Eficiencia de Disipadores por Fluencia Usados para la Rehabilitacin de Prticos. Palazzo, G., Lpez-Almansa, F., Cahs, X., & Crisafulli, (2008). F. Individual testing of dissipative buckling restrained braces.

Ramirez, O. M., Constantinou, M. C., Whittaker, A. S., Kircher, C. A., & Chrysostomou, C. Z. (2002). Elastic and inelastic seismic response of buildings with damping systems. Earthquake Spectra, 18(3), 531-547. Ribakov, Y. and Gluck, J., (1999). "Optimal Design of ADAS Damped MDOF Structures," Earthquake Spectra, 15(2), 317-330. Scholl, R. E., (1993). "Design Criteria for Yielding and Friction Energy Dissipators", ATC-17-1 Seminar on Seismic Isolation, Passive Energy Dissipation, and ActiveControl, San Francisco, CA, 485-496. Skinner, R. I.,et al. (1980). "Hysteretic dampers for the protection of structures from earthquakes." Bulletin, New Zealand National Society for Earthquake Engineering 13.1 Soong, T.T. and Dargush, G.F. (1999). Passive Energy Dissipation and Active Control Structural Engineering Handbook Ed. Chen Wai-Fah Boca Raton: CRC Press LLC, Soong, T. T., & Spencer Jr, B. F. (2002). Supplemental energy dissipation: state-of-the-art and state-of-thepractice. Engineering Structures, 24(3), 243-259. Soong, T. T. and Dargush, G. F., (1997). Passive Energy Dissipation Systems in Structural Engineering, JohnWiley & Sons, New York, NY. De la Cruz, S. T., F. Lpez-Almansa, and C. Taylor, (2008). "Tests of friction energy dissipators for seismic protection of buildings." Symans, M. D., Charney, F. A., Whittaker, A. S., Constantinou, M. C., Kircher, C. A., Johnson, M. W., & McNamara, R. J. (2008). Energy dissipation systems for seismic applications: current practice and recent developments. Journal of structural engineering, 134(1), 3-21. Xia, C. and Hanson, R., (1992). "Influence of ADAS Element Parameters on Building Seismic Response," Journal of Structural Engineering, 118, 1903-1918. Zabala, Francisco, et al. (2003). "Desarrollo de Disipadores de Fluencia de Metales y su Aplicacin a Sistemas Pasivos de Proteccin Ssmica." Memorias del 6 Encuentro de Investigadores y Profesionales Argentinos de la Construccin. Gustavo L. Palazzo et al (2008). Simulacin Numrica de Estructuras Reforzadas con Disipadores de Energa Sometidas a Excitacin Ssmica. Kelly, J. M., Skinner, R. I. y Heine, A.J. (1972). Mechanisms of energy absorption in special devices for use in earthquake resistant structures, Bulletin of the New Zealand National Society for Earthquake Engineering, Vol. 5, Nro. 3, pp. 63-68. Kelly, J. M. (1993). Earthquake-resistant design with rubber. London: Springer-Verlag. Skinner, R.I., Kelly, J. M., y Heine, A.J. (1975). Hysteretic dampers for earthquake -resistant structures, Earthquake Engineering and Structural Dynamics, Vol. 3, pp. 287-296.

Bergman, D. M. y Goel, S. C. (1987). Evaluation of Cyclic Testing of Steel-Plate Devices for Added Damping Dissipators, Report UMCE 87-10, Civil Engineering Department, University of Michigan, Ann Arbor, USA. Kobori, T., Yamada, T., Takenaka, Y., Maeda, Y., y Nishimura, I. (1988). Effec t of dynamic tuned connector on reduction of seismic response-application to adjacent office buildings, Proceedings of 9th World Conference on Earthquake Engineering, Vol. 5, Tokyo/Kyoto, Japan. Kajima Corporation (1991). Honeycomb Damper Systems, www.kajima.co.jp. Tsai, K. C., Chen, H.W., Hong, C. P. y Su, Y. F. (1993). Design of steel triangular plate energy absorbers for seismicresistance construction, Earthquake Spectra, Vol. 9,Nro. 3, pp. 505 -528. KIS (2003). Kyoto University www.steel.dpri.kyotou.ac.jp/kis2003. Experimental Project Eart hquake-Resistant Steel Frames,

INTRODUCCIN Es sabido que durante el transcurso de la historia, chile ha sido azotado por eventos ssmicos de gran magnitud, colocando a prueba la capacidad resistente de las estructuras. Tales eventos provocan prdidas humanas, econmicas y daos estructurales. Es por esto, que en los ltimos aos se han desarrollar sistemas de control de vibraciones. Estos avances se dividen en tres grupos: sistemas pasivos, tales como aislamiento en la base y dispositivos suplementarios de disipacin de energa; sistemas activos, los cuales requieren la participacin activa de dispositivos mecnicos cuyas caractersticas estn hechas para cambiar durante la respuesta ssmica basndose en medidas de respuesta; y sistemas hbridos, los cuales combinan los sistemas pasivos y activos en una manera tal que la seguridad del edificio no este comprometida incluso si el sistema activo fallase. La aplicacin de estos conceptos se materializa incorporando dispositivos mecnicos en las construcciones, con el objetivo de controlar la respuesta y demanda de disipacin ssmica sobre los elementos estructurales, (Aiken, 1996; Soong 1997).

Dentro de los sistemas de proteccin, el ms prctico y fiable de reduccin de la respuesta ssmica estructural es el uso de sistemas de control de respuesta pasiva, estos son mecanismos simples y efectivos de disipacin de energa a travs de la deformacin inelstica de los metales, esta clase de dispositivos se les llaman pasivos, porque no requieren ninguna fuente de energa adicional para operar, activndose slo con el movimiento originado por una solicitacin dinmica. El concepto se remonta a los trabajos de Kelly (Kelly et al., 1972) y Skinner (Skinner et al., 1975) en Nueva Zelanda, dando inicio a una gran variedad de dispositivos, que en su mayora utilizan la fluencia de metales (comportamiento histertico) para disipar la energa. Los dispositivos metlicos ms conocidos son el ADAS (Added Damping AndStiffness) (Bergman y Goel, 1987; Whittaker et al., 1991), el sistema Honeycomb (Kobori et al., 1988; Kajima Corporation, 1991), y TADAS (Triangular Plates Added Damping And Stiffness) (Tsai et al., 1993).

Las ltimas tres dcadas han sido testigo de la investigacin y desarrollo de los dispositivos de disipacin pasivos de energa para aplicaciones de ingeniera estructural. As mismo, en Japn se estn desarrollando y evaluando experimentalmente disipadores metlicos histerticos ubicados en el propio nudo de viga y columna (KIS, 2003; Koetaka et al., 2005; Suita et al., 2001), donde la energa provocada por el sismo es disipada principalmente por el dispositivo amortiguador. En nuestro pas el diseo y construccin de edificios aislados, da sus primeros pasos en el ao 1992 con la construccin del condominio Andaluca, ubicado en la calle Lord Cochrane, el siguiente edificio construido en el 2001 corresponde a la clnica Universidad Catlica San Carlos de Apoquindo, con

52 aisladores de alto amortiguamiento, el ao 2002 se construy el tercer edificio aislado, la Facultad de Ingeniera de la Universidad Catlica que cuenta con 53 aisladores, a mediados del ao 2004 se da inicio a la construccin del proyecto aislado de mayor envergadura, el Hospital Militar, el cual consta de 164 aisladores, el ao 2005 se construye el edificio Vulco, siendo el primer edificio prefabricado aislado, ese mismo ao se utiliza la tcnica de disposicin de engera en base a masa sintonizada para el edificio Parque Araucano, posteriormente en el ao 2008 la torre Titanium es el edificio aislado de mayor altura construido en chile, el ao 2009 se usa el sistema de disipacin de energa en el muelle puerto de coronel, y finalmente, en el ao 2010 se construyen 3 estructuras aisladas: edificio infante, edificio agustinas y el edificio magnus II.

Todas estas tecnologas presentan un incremento en el rol que juegan en el diseo estructural, es por ello, que la presente investigacin est orientada al desarrollo de un dispositivo pasivos de disipacin de energa, cuya funcin bsica cuando son incorporados a la superestructura es absorber una parte de la energa de entrada, para de esta manera reducir la demanda de disipacin de energa.

OBJETIVO GENERAL Analizar la eficiencia de un dispositivo de disipacin pasiva de energa, en la respuesta ssmica de superestructuras sometidas a aceleraciones en la base.

OBJETIVOS ESPECFICOS Los objetivos especficos planteados en esta investigacin son los siguientes:

a) Presentar las bases tericas y modelos matemticos utilizados en la actualidad para la simulacin de estructuras con la incorporacin de disipadores pasivos de energa. b) Determinar la respuesta ssmica de superestructuras, a travs de la formulacin de un programa, en formato MATLAB, implementando el sistema de disipacin pasiva de energa, de acuerdo al procedimiento de diseo establecido. c) Validar los resultados entregados por el modelo, mediante la realizacin de un ejemplo prctico en relacin al diseo de disipadores en edificios y comparar los resultados del anlisis, con lo entregado por el software comercial Sap2000 Non-Linear.