You are on page 1of 2

HIGH EFFICIENCY MULTICRYSTAL PHOTOVOLTAIC MODULE

KD100-36 Series
KD135GX-LFBS KD140GX-LFBS

Cutting Edge Technology


As a pioneer with over 35 years in the solar energy industry, Kyocera demonstrates leadership in the development of solar energy products. Kyoceras Kaizen Philosophy, commitment to continuous improvement, is shown by repeatedly achieving world record cell efciencies.

Quality Built In
UV stabilized, aesthetically pleasing black anodized frame Supported by major mounting structure manufacturers Easily accessible grounding points on all four corners for fast installation Proven junction box technology with 12 AWG PV wire to work with transformerless inverters Quality locking plug-in connectors to provide safe and quick connections

Reliable
Proven superior eld performance Tight power tolerance First module manufacturer to pass rigorous long-term testing performed by TV Rheinland

Qualifications and Certifications


UL Listing QIGU.E173074 NEC 2008 Compliant, UL 1703, ISO 9001, and ISO 14001 UL1703 Certied and Registered, UL Fire Safety Class C, CEC, FSEC Certied IEC61215 Ed 2 IEC61730 by JET
Manufactured in San Diego, Califor nia Available Upon Request

KD100-36 Series

Electrical SPECIFICATIONS
Standard Test Conditions (STC)
STC = 1000 W/M2 irradiance, 25oC module temperature, AM 1.5 spectrum*

Module CHaracteristics
Dimensions: length/width/height Weight: 59.06in/26.30in/1.8in (1500mm/668mm/46mm) 28.4lbs (12.9kg)

KD135GX-LFBS
Pmp Vmp Imp Voc Isc Ptolerance

KD140GX-LFBS

135 17.7 7.63 22.1 8.37 +5/-5

140 17.7 7.91 22.1 8.68 +5/-5

W V A V A %

PACKAGING SPECIFICATIONS
Modules per pallet: Pallets per 53 container: Pallet box dimensions: length/width/height Pallet box weight:
KD 135 F
4.84in 123mm 1.8in 46mm

20 54 63.19in/27.56in/49.02in (1605mm/700mm/1245mm) 650lbs (295kg)

Nominal Operating Cell Temperature Conditions (NOCT)


TNOCT Pmax Vmp Imp Voc Isc PTC

NOCT = 800 W/M2 irradiance, 20oC ambient temperature, AM 1.5 spectrum*


10.96in 278.5mm 3.61in 91.6mm

45 97 16.0 6.10 20.2 6.78 120.3

45 101 16.0 6.33 20.2 7.03 124.9

V A V
59.06in 1500mm 18.56in 471.5mm

A W

STABILIZER BAR
18.56in 471.5mm

Temperature Coefcients
Pmax Vmp Imp Voc Isc Operating Temp

-0.45 -0.52 0.0066 -0.36 0.060 -40 to +90

-0.45 -0.52 0.0066 -0.36 0.060 -40 to +90

%/oC %/oC %/ C
o

10.96in 278.5mm

39.8in 1010mm

33.1in 840mm

(IP65)

26.30in 668mm

.49in 12.5mm

%/oC
.47in 12mm

%/oC
o

C
1.18in 30mm

1.8in 46mm Short Side

10.96in 278.5mm

System Design
Series Fuse Rating Maximum DC System Voltage (UL) Hailstone Impact
* Subject to simulator measurement uncertainty of +/- 3%. KYOCERA reserves the right to modify these specications without notice.

.41in 10.3mm

600 V
Long Side .79in 20mm

1in (25mm) @ 51mph (23m/s)

Expanded View of Grounding Holes

Frame Cross Section Diagrams

NEC 2008 Compliant UL 1703 Listed Certified IEC61215 Ed2 IEC61730 by JET 082412

WARNING: Read the instruction manual in its entirety prior to handling, installing & operating Kyocera Solar modules.

MOUNTING HOLES .35in (9mm)

DRAINAGE HOLES

GROUND SYMBOL .35in (9mm)

OUR VALUED PARTNER

KYOCERA Solar, Inc.

800-223-9580 800-523-2329 fax

www.kyocerasolar.com

1.8in 46mm

15 A