You are on page 1of 10

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

JCI VRF Selection Software V1.37


Project Name
Client Name
Client Address
Memo

System Report

4/11/2014

Transnet
Imogen
Braamfontein

Selection parameters of the indoor units can be found under the official documents of Indoor unit details;
Selection parameters of the outdoor units can be found under the official documents of Outdoor unit details;

In any case of unclear problems, please contact with Johnson controls ,inc. Engineers for solutions, This software is just an
assistant tool for JCI VRF Selection, we suggest you contact with Johnson controls ,inc. Engineers for confirmation before you
adopt the solution given by this software.

1. Material List
Model
YVKVXH056WAR--GX
YVGVXH056WAR--GX
YVGVXH090WAR--GX
YVGVXH112WAR--GX
YVGVXH140WAR--GX
YVGVXH280WAR--GX
PB-950JB

Unit
set
set
set
set
set
set
set

QTY
3
1
1
3
1
1
3

YV2VYH106KAS-D-X

set

FQG-B506A
FQG-B730A
FQG-B1350A
HZG-30A
YR-E14
iGU02
HCM-01
R410A
Total

set
set
set
set
set
set
set
Kg

1
2
6
1
10
1
1
7.5

Memo
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor Panel
Amazon Standard Ambient VRF-380V
Outdoor unit
Branch pipe
Branch pipe
Branch pipe
Outdoor branch pipe
Wired controllor
BacNet Translator
BacNet Converter
Ground Floor-7.5

Note: 1 Ammeter should be purchased locally.


Note: Tender specified 67 Kw outdoor unit, Actual capacity is 110 Kw

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
1

Price($)
0
0
0
0
0
0
0

Sum Price($)
0
0
0
0
0
0
0

0
0
0
0
0
0
0
0

0
0
0
0
0
0
0
0
0

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

2. Indoor/Outdoor Match
Outdoor unit

Room

Ground Floor--YV2VYH106KAS-D-X

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
2

Indoor unit
Ind1--YVKVXH056WAR--GX
Ind2--YVKVXH056WAR--GX
Ind3--YVKVXH056WAR--GX
Ind4--YVGVXH056WAR--GX
Ind5--YVGVXH090WAR--GX
Ind6--YVGVXH112WAR--GX
Ind7--YVGVXH112WAR--GX
Ind8--YVGVXH112WAR--GX
Ind9--YVGVXH140WAR--GX
Ind10--YVGVXH280WAR--GX

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

3. Indoor Dip switch(0:OFF, 1:ON)


When YR-E14 used in group control system , the first unit of group control connection is set as master unit;
Name
Ind1
Ind2
Ind3
Ind4
Ind5
Ind6
Ind7
Ind8
Ind9
Ind10

Model
YVKVXH056WAR-GX
YVKVXH056WAR-GX
YVKVXH056WAR-GX
YVGVXH056WAR-GX
YVGVXH090WAR-GX
YVGVXH112WAR-GX
YVGVXH112WAR-GX
YVGVXH112WAR-GX
YVGVXH140WAR-GX
YVGVXH280WAR-GX

SW01

SW02

SW03

SW07

SW08

CN23

CN30

CN21

00000110

10000000

11000000

11111111

11110111

ON

ON

OFF

00000110

10000001

11000001

11111111

11110111

ON

ON

OFF

00000110

10000010

11000010

11111111

11110111

ON

ON

OFF

00000110

10000011

11000011

11111111

11110111

ON

ON

OFF

00001001

10000100

11000100

11111111

11110111

ON

ON

OFF

00001010

10000101

11000101

11111111

11110111

ON

ON

OFF

00001010

10000110

11000110

11111111

11110111

ON

ON

OFF

00001010

10000111

11000111

11111111

11110111

ON

ON

OFF

00001011

10001000

11001000

11111111

11110111

ON

ON

OFF

00001011

10001001

11001001

11111111

11110111

ON

ON

OFF

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
3

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

4. Outdoor Dip switch(0:OFF, 1:ON)


The 1st & 2nd bit of BM1 of master unit should be set 0(Off position) before power on , after power on and finishing searching indoor and
outdoor address ,set 1st & 2nd bit of BM1 to 1 (On position).
Name

Model
YV2VYH045KAS-D
-X
Ground
YV2VYH033KAS-D
Floor--YV2VYH106KAS-D
-X
-X
YV2VYH028KAS-D
-X

BM1

BM2

BM3

BM4

BM5

11000000

00000000

00000101

00000000

11000011

11000001

00000000

00000011

00000000

11000011

11000010

00000000

00000010

00000000

00110011

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
4

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

5. Indoor units details


5.1

Ground Floor----YV2VYH106KAS-D-X

The outdoor unit's combination is(97.1%),the details of connected indoor units are:
Name

Ind1
Ind2
Ind3
Ind4
Ind5
Ind6
Ind7
Ind8
Ind9
Ind10

Model

Std
Cooling Heating
Std Heating
Cooling
Airflow(H)
Capacity Capacity
DB/WB
DB/WB
kW
kW
C
C
m/h

YVKVXH056WAR-GX
YVKVXH056WAR-GX
YVKVXH056WAR-GX
YVGVXH056WAR-GX
YVGVXH090WAR-GX
YVGVXH112WAR-GX
YVGVXH112WAR-GX
YVGVXH112WAR-GX
YVGVXH140WAR-GX
YVGVXH280WAR-GX

Noise

Size

Weight

dB(A)

mm
840*240*840(Panel:950
*80*950)
840*240*840(Panel:950
*80*950)
840*240*840(Panel:950
*80*950)

Kg

5.6

6.3

27/19.4

20/14.5

1200

34/32/30

5.6

6.3

27/19.4

20/14.5

1200

34/32/30

5.6

6.3

27/19.4

20/14.5

1200

34/32/30

5.6

6.3

27/19.4

20/14.5

1600

42/40

970*360*875

56

10

27/19.4

20/14.5

2100

45/40

1350*360*875

62

11.2

12.5

27/19.4

20/14.5

2100

45/40

1350*360*875

62

11.2

12.5

27/19.4

20/14.5

2100

45/40

1350*360*875

62

11.2

12.5

27/19.4

20/14.5

2100

45/40

1350*360*875

62

14

16

27/19.4

20/14.5

2100

45/40

1350*360*875

62

28

31.5

27/19.4

20/14.5

4050

54/49

1670*360*880

92

107

120.2

Size

Weight

mm
990*1808*750+(1390*
1808*750)*2

Kg

Total

36
36
36

6. Outdoor units details


Name

Model

Ground
Floor

YV2VYH106KAS-D
-X

Name

Model

Ground
Floor

YV2VYH106KAS-D
-X

Std
Combinatio Cooling Heating
Std Heating
Cooling
Max pipe Len
n
Capacity Capacity
DB/WB
DB/WB
%
kW
kW
C
C
m
100

Refrigerant
added
Kg
30

110.1

122.8

35/23.9

Power type

3N~,380~400V,50/60Hz

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
5

8.3/6.1

135

968

Cooling
running Cur
A

Cooling Max
Cur
A

Heating
running Cur
A

Heating Max
Cur
A

49

83.67

50.6

83.67

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

7. Piping diagram
7.1

Ground Floor

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
6

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

8. Wiring diagram
8.1

Ground Floor

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
7

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

9. BMS diagram

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
8

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

10. Max pipe Len&Drop

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
9

JCI VRF Selection

Transnet

------------------------------------------------------------------------------------------------------------------------------------------------------------

11. Refrigerant charging

The JCI VRF Selection Software is property of Johnson controls ,inc. Ltd.
10