Diagnostics and Troubleshooting : Troubleshooting

Troubleshooting
Table 28 provides a list of issues, possible causes, and recommended
actions.

TABLE 28 Troubleshooting the Brocade DCX


Issue

Possible cause

Recommended action

Entire chassis pow ers off


automatically.

Pow er supplies are inadequate to support


the installed components.

Add an additional pow er supply.

Several or all components are not


operating.

One or both pow er cables may not be


connected to a live source.

Ensure that both pow er cables are connected to


live outlets.

One or both AC pow er sw itches might be


off.

Ensure that both AC pow er sw itches are on (AC


sw itches light up green w hen on).

Serial cable is not connected correctly.

Ensure that the cable is firmly connected to


w orkstation computer and to the Brocade DCX.

Serial connection is faulty or serial


port logs have incorrect or missing
information.

Terminal emulator application parameters are Ensure that the terminal emulator application is
not set correctly.
configured as follow s: 9600 bits per second, 8
databits, no parity, 1 stop bit, no flow control.
Serial port might be incompatible (only RS232 is supported).

Ensure that the Brocade DCX is connected to an


RS-232 port. RS-423 serial ports might experience
difficulties due to corner-case incompatibilities of
the standards.

Pins on the serial cable or serial port might


be damaged.

Remove the cable and inspect the pins on the cable


and in the serial port. Do not reinstall if the pins on
either component have any visible damage, as this
could damage the pins on the other component.
Replace the components as required.

CP Ethernet link speed is different


than expected or a link cannot be
established.

There might be a conflict w ith the CP


Ethernet link speed negotiation set up by the
netw ork.

Specify the CP Ethernet link speed by entering the


ifModeSet command.
For more information about Ethernet connectivity to
the Brocade DCX, refer to the LAN guidelines
provided through the MyBrocade Web site.

Configuration data is inaccurate or


cannot be accessed.

Chassis w as pow ered off/on w hile a WWN


card w as uninstalled or failed.

Install an operational WWN card and pow er the


system off/on again.

The Brocade DCX w as rebooted w hile a


WWN card w as uninstalled or failed.
http://www.brocade.com/downloads/documents/html_product_manuals/DCX_HRM/wwhelp/wwhimpl/common/html/wwhelp.htm#context=53-1000685-13&file=Trou

1/2