Data Sheet 10/63-6.47-EN Rev.

D
PROFIBUS cable







PROFIBUS DP cables
Non-Ex (Hazardous) applications
Ex (Hazardous) applications

PROFIBUS PA cables
Non-Ex (Hazardous) applications
Ex (Hazardous) applications







PROFIBUS cable


2 10/63-6.47-EN Rev. D | PROFIBUS cable
PROFIBUS DP cable (solid)

M10773
NDC110-NO, NDC110-EX
Application

(Example Sketch)
Standard zero halogen fieldbus cable for PROFIBUS DP/FMS and FIP, suitable for 9-pin SUB-D [IP20] and M12 [IP67]
connectors.
[FB-02YS(St+Ce)H]
Recommended for indoor and outdoor installation, in dry and wet locations, on racks, on trys and in conduits.
Not suitable for direct burial.
Also especially in locations where the low smoke , zero halogen and flame retardant characteristics are important
(e. g. public buildings, hospitals, power stations etc.).
Internet http://www.abb.com/fieldbus

Standard IEC 61158 Part 2
Classification Typ A
Interface RS 485(-IS)
Conductor plain annealed copper wire, solid
AWG 22/1 0.33 mm
2
, 0.65 mm
Insulation foamed polyethylene with skin layer

Color code a(N)-core: green, b(P)-core: red
Screen plastic coated aluminum tape, metallic surface outside in contact with a tinned copper drain wire and tinned copper wire braid
Outer sheath Low smoke, zero halogen flame retardant compound LSZH, color: violet (NDC110-NO), blue [IS] (NDC110-EX)
Cable marking FIELDBUS CABLE IEC 61158-2 150 PLTC PROFIBUS FMS/DP 1 PR 22 AWG OS (UL) 75C SUN RES E107687 length
marking

Overall diameter 7.9 0,5 mm
Weight approx. 70 kg/km
Max. pulling tension 35 N
Min. bending radius 7.5 x cable overall diameter
Temperature range -40 ... 75 C during operation, -5 ... 50 C during installation
UV resistant UL 1581 article 1200
Oil resistant ICEA S-73-532 (Test temperature 60 C; duration 4 h. Retention: min. 60 % of tensile strength/min. 60 % of elongation)
Flame propagation Test on single cable: UL 13 (vertical tray), Test on bunched cable: IEC 60332-3-24 (Cat. C)
Smoke density low, IEC 61034-1 and 2 (L.T. > 60%)
Halogen free yes, IEC 60754-1, 0 %
Degree of acidity of gases IEC 60754-2 (pH 4.3, c 10 S/mm)
Limiting Oxygen Index (LOI) ASTM D 2863, (min. 30 %)
Explosion protection (NDC110-EX only) for Ex i applications [IS], Class I / II Division 2 acc. to NEC 501.10(B) and NEC 502.10(B) or Zone 1 / 2,
Group II, acc. 60079-14.
FISCO-approval
Approval CE, UL (listed as PLTC acc. to UL 13)

M10775
PROFIBUS cable | 10/63-6.47-EN Rev. D 3
PROFIBUS DP cable (solid)

M10773
NDC110-NO, NDC110-EX

Electrical properties at 20 C
Conductor resistance
(Loop)
max. 110 /km
Screen resistance nom. 12 /km
Attenuation at 0.25 /
0.625 / 1.25 / 3.125 /
16 MHz
nom. 6 / 9 / 12 / 18 / 40 dB/km
Inductance nom. 0.9 mH/km
Mutual capacitance max. 30 nF/km
Capac. unbalance to
earth
max. 1.5 nF/km
Impedance at 3 MHz 150 15
Test voltage
(Core / core and
core / screen)
1500 V
Operating voltage max. 300 V


PROFIBUS cable


4 10/63-6.47-EN Rev. D | PROFIBUS cable
PROFIBUS PA cable

NPC080-NO, NPC080-EX NPC150-NO, NPC150-EX NPC250-NO, NPC250-EX
Application
M10772

(Example Sketch)
Standard fieldbus cable for PROFIBUS
PA with additional power supply for the
devices, suitable for insulation
displacement connections or M12
connectors.
[FB-02YS(St+Ce)Y-fl]
Long-distance fieldbus cable for PROFIBUS PA with additional power supply for
the devices, cable with low voltage drop along the line.
[FB-2Y(St+Ce)Y-fl]

Recommended for indoor and outdoor installation, in dry and wet locations, on racks, on trys and in conduits. Not suitable for
direct burial.
Internet http://www.abb.com/fieldbus

Standard IEC 61158 Part 2
Classification Typ A
Interface MBP-LP(-IS), IEC 61158
Conductor plain annealed copper wire, stranded
AWG 18/7 0.88 mm
2
AWG 16/7 1.3 mm
2
AWG 14/7 2.1 mm
2

Insulation foamed polyethylene with skin layer polyethylene

Color code a(-)-core: green, b(+)-core: red
Screen plastic coated aluminium tape, metallic surface outside in contact with a tinned copper drain wire and tinned copper wire braid
Outer sheath polyvinyl chloride PVC, color: black (NPCnnn-NO), blue [IS] (NPCnnn-EX)
Cable marking FIELDBUS CABLE IEC 61158-2 100 PLTC PROFIBUS PA 1 PR xx AWG OS (UL) 75C SUN RES E107687 length
marking

Overall diameter 7.6 0,4 mm 9.4 0,6 mm 11.5 1.0 mm
Weight approx. 75 kg/km approx. 114 kg/km approx. 166 kg/km
Max. pulling tension 90 N 130 N 200 N
Min. bending radius 7.5 x cable overall diameter
Temperature range -40 ... 75 C during operation, -5 ... 50 C for installation
UV resistant UL 1581 article 1200
Oil resistant ICEA S-73-532
Flame propagation Test on single cable: UL 13 (vertical tray), Test on bunched cable: IEC 60332-3-24 (Cat. C)
Smoke density
Halogen free
HCL emission IEC 60754-1, max. 17 %
Oxygen index of outer sheath ASTM D 2863 (min. 30 %)
Explosion protection (NPCnnn-EX only) for Ex i applications [IS], Class I / II Division 2 acc. to NEC 501.10(B) and NEC 502.10(B) or Zone 1 / 2,
Group II, acc. to IEC 60079-14.
FISCO approval FISCO not for passive components
Approval CE, UL (listed as PLTC acc. to UL 13)

PROFIBUS cable | 10/63-6.47-EN Rev. D 5
PROFIBUS PA cable

NPC080-NO, NPC080-EX NPC150-NO, NPC150-EX NPC250-NO, NPC250-EX

Electrical properties at 20 C
Conductor resista.
(Loop) (R
c
)
max. 43.6 /km max. 28.5 /km max. 17.9 /km
Screen resistance nom. 12 /km
Attenuation at 39 kHz max. 3.0 dB/km
Inductance (L
c
) nom. 0.7 mH/km
Mutual capacitance (C
c
) nom. 60 nF/km
Capac. unbalance to
earth
max. 4 nF/km
Impedance 100 20
Propagation delay
change
(7.9 kHz 39 kHz)
max. 1.7 s/km
Test voltage
(Core / core and
core / screen)
1500 V
Operating voltage max. 300 V



PROFIBUS cable


6 10/63-6.47-EN Rev. D | PROFIBUS cable
Ordering information
PROFIBUS DP cable Catalog No.
NDC110-NO 65 m (79260301) 9890140
PROFIBUS DP cable solid, violet, 2 x 0.33 mm
2
(AWG22/1), Type A.
Impedance 150 15 / >= 3 MHz, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in
conduits.

330 m (79260301) (Note 1) 9890141
PROFIBUS DP cable solid, violet, 2 x 0.33 mm
2
(AWG22/1), Type A.
Impedance 150 15 / >= 3 MHz, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in
conduits.

1000 m (79260301) (Note 1) 9890142
PROFIBUS DP cable solid, violet, 2 x 0.33 mm
2
(AWG22/1), Type A.
Impedance 150 15 / >= 3 MHz, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in
conduits.

NDC110-EX 65 m (79260302) 9890143
PROFIBUS DP cable solid, blue!, 2 x 0.33 mm
2
(AWG22/1), Type A, for intrinsic safety applications (Ex i).
Impedance 150 15 / >= 3 MHz, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in
conduits.

330 m (79260302) (Note 1) 9890144
PROFIBUS DP cable solid, blue!, 2 x 0.33 mm
2
(AWG22/1), Type A, for intrinsic safety applications (Ex i).
Impedance 150 15 / >= 3 MHz, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in
conduits.

1000 m (79260302) (Note 1) 9890145
PROFIBUS DP cable solid, blue!, 2 x 0.33 mm
2
(AWG22/1), Type A, for intrinsic safety applications (Ex i).
Impedance 150 15 / >= 3 MHz, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in
conduits.


Note 1: incl. no-return cabl e drum



PROFIBUS cable | 10/63-6.47-EN Rev. D 7


PROFIBUS PA cable Catalog No.
NPC080-NO 65 m (76770101) 9890130
PROFIBUS PA cable, black, 2 x 0.88 mm
2
(AWG18/7), Type A.
Loop resistance 43.6 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

330 m (76770101) (Note 1) 9890131
PROFIBUS PA cable, black, 2 x 0.88 mm
2
(AWG18/7), Type A.
Loop resistance 43.6 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

1000 m (76770101) (Note 1) 9890132
PROFIBUS PA cable, black, 2 x 0.88 mm
2
(AWG18/7), Type A.
Loop resistance 43.6 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

NPC150-NO 1000 m (79290101) (Note 1) 9890133
PROFIBUS PA cable, black, 2 x 1.3 mm
2
(AWG16/7), Type A.
Loop resistance 28.5 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

NPC250-NO 1000 m (79290103) (Note 1) 9890138
PROFIBUS PA cable, black, 2 x 2.1 mm
2
(AWG14/7), Type A.
Loop resistance 17.9 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

NPC080-EX 65 m (76770100) 9890134
PROFIBUS PA cable, blue, 2 x 0.88 mm
2
(AWG18/7), Type A, for intrinsic safety applications (Ex i).
Loop resistance 43.6 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

330 m (76770100) (Note 1) 9890135
PROFIBUS PA cable, blue, 2 x 0.88 mm
2
(AWG18/7), Type A, for intrinsic safety applications (Ex i).
Loop resistance 43.6 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

1000 m (76770100) (Note 1) 9890136
PROFIBUS PA cable, blue, 2 x 0.88 mm
2
(AWG18/7), Type A, for intrinsic safety applications (Ex i).
Loop resistance 43.6 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

NPC150-EX 1000 m (79290100) (Note 1) 9890137
PROFIBUS PA cable, blue, 2 x 1.3 mm
2
(AWG16/7), Type A, for intrinsic safety applications (Ex i).
Loop resistance 28.5 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.

NPC250-EX 1000 m (79290102) (Note 1) 9890139
PROFIBUS PA cable, blue, 2 x 2.1 mm
2
(AWG14/7), Type A, for intrinsic safety applications (Ex i).
Loop resistance 17.9 /km, UL approval, incl. special drain wire, for fixed installation indoor and outdoor, on racks and in conduits.


Note 1: incl. no-return cabl e drum






Contact us

1
0
/
6
3
-
6
.
4
7
-
E
N

R
e
v
.

D

1
1
.
2
0
1
2

ABB Automation GmbH
Service Instrumentation
Kallstadter Strae 1
68309 Mannheim, Germany
Customer service center: +49 (0)180 5 222 580
*

E-Mail: automation.service@de.abb.com

www.abb.com

*
14 cents/minute from German landlines,
max. 42 cents/minute from mobiles.


Note
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
responsibility whatsoever for potential errors or
possible lack of information in this document.

We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents - in whole or in parts is
forbidden without prior written consent of ABB.

Copyright 2012 ABB
All rights reserved

3KXN647000R1001