Professional Documents
Culture Documents
3¹⁄₂"
LINE
PLAT
E
₆"
10⁷⁄₁
3³⁄₈"
PLA
TE
LIN
E
1³⁄₄"
H2.5 H2.5A
H1
1¹⁄₂" H2.5T
H2 H2A
H3 H4 H5
C-2009 © 2008 SIMPSON STRONG-TIE COMPANY INC. PRINTED 12/08
3¹⁄₂"
6¹⁄₄"
11⁵⁄₈"
5"
H10
(H10R similar) H10A
H8
3"
H10S
H14
Profile
LINE
PLAT
E
PLATE
LINE
2 3 4 5
1
H2A Installation H2.5 Installation H2.5A Installation H2.5T Installation
H1 Installation (H2 similar) (Nails into both top plates) (Nails into both top plates) (Nails into both top plates)
8 H4
7 Installation
H3 Installation (H2.5 similar)
(Nails into upper top plate) (see footnote 3)
6 H2.5T Installation
11
9 H6 Stud
10
H4 Installation H5 Installation
to Top Plate 12 H6 Stud to Band 13 H7Z Installation
Installation Joist Installation
156 (Nails into upper top plate) (Nails into both top plates)
Straps & Ties
18
Plate nails
for lateral H10S
loads only Installation
14 H8 attaching 15
H8 attaching 16 H8 attaching
stud to sill I-joist to double 17 H10 Installation
rafter to double
top plates (4-8d into plate, top plates
5-8d into stud, Minimum
refer to footnote Edge 22 H14 Installation to
3 for loads) Distance double top plates
³⁄₈"
8d commons to
plates. Fill one of AVOID A
three holes to H14 MISINSTALLATION
bottom flange.
1
Plate nails
for lateral
loads only Minimum
H10-2 Installation Edge
21 Distance
(H11Z similar) ³⁄₈"
VB Knee Braces
The VB provides lateral resistance force at the bottom of beams 2¹⁄₂" Min.
when installed approximately 45° or more to the vertical plane.
MATERIAL: 12 gauge FINISH: Galvanized Hanger
INSTALLATION: • Use specified fasteners. See General Notes. not shown
• 16-N54A fasteners are included with the brace.
CODES: See page 12 for Code Reference Key Chart. Six N54A
Nails
1⁵⁄₈"
DF/SP SPF/HF
Fasteners
Allowable Loads1 Allowable Loads1
Model Code
Ga To Lateral Lateral 2¹⁄₄"
No. To To Uplift Uplift Ref.
Rafters/ (160) (160) HS24
Plates Studs
Truss (160) F1 F2 (160) F1 F2 U.S. Patents
5,603,580
HGA10KT 14 4-SDS ¹⁄₄"x1¹⁄₂" 4-SDS ¹⁄₄"x3" — 695 1165 940 500 840 675 F26 3⁹
⁄₁₆" 2⁵⁄₈"
HS24 18 8-8dx1¹⁄₂ 8-8d — 605 3
645 3
1025 3
520 3
555 3
880 3
& 2-8d slant
I17, F16
H15 16 4-10dx1¹⁄₂ 4-10dx1¹⁄₂ 12-10dx1¹⁄₂ 1300 480 — 1120 410 —
H15-2 16 4-10dx1¹⁄₂ 4-10dx1¹⁄₂ 12-10dx1¹⁄₂ 1300 480 — 1120 410 —
H16 18 2-10dx1¹⁄₂ 10-10dx1¹⁄₂ — 1470 — — 1265 — —
H16S 18 2-10dx1¹⁄₂ 10-10dx1¹⁄₂ — 1470 — — 1265 — —
F26
H16-2 18 2-10dx1¹⁄₂ 10-10dx1¹⁄₂ — 1470 — — 1265 — —
H16-2S 18 2-10dx1¹⁄₂ 10-10dx1¹⁄₂ — 1470 — — 1265 — —
F2
1. Loads have been increased for wind or earthquake loading with no further increase allowed; reduce where other loads govern.
2. When cross-grain bending or cross-grain tension cannot be avoided, mechanical reinforcement to resist such forces F1
should be considered.
3. HS24 DF/SP allowable loads without slant nailing are 605 lbs. (uplift), 590 lbs. (F1), 640 lbs. (F2).
For SPF/HF loads multiply these values by 0.86.
4. For H16-2S, S = short.
5. Allowable loads in the F1 direction are not intended to replace diaphragm boundary members HS24 Installation
or prevent cross grain bending of the truss or rafter members. Additional shear transfer
elements shall be considered where there may be effects of cross grain bending or tension.
6. NAILS: 10dx1¹⁄₂ = 0.148" dia. x 1¹⁄₂" long, 8d = 0.131" dia. x 2¹⁄₂" long,
Depending on
heel height,
strap may wrap
to back of plate.
Depending on
heel height, H16-2
strap may wrap and
to back of plate.
H16-2S
Presloped at
5:12. Pitch of
3:12 to 7:12
is acceptable Install 4-10dx1¹⁄₂ to Install 6-10dx1¹⁄₂
inside edge of 2x to face of 2x
H16-2 Installation
H16 Installation
H16
and H16S
Presloped at
5:12. Truss/
Rafter Pitch of HGA10
3:12 to 7:12
is acceptable HGA10
HGA10 Installation
Installation to to Rim Joist
Double Top Plates
158