You are on page 1of 4

Contrast scanner with static

Teach-in on mark and


background
When especially high precision is required for contrast detection, e.g., in detecting marks
on highly polished materials, the time (or more precisely the millisecond) is ripe for
the KT5W-2___6 contrast scanner.
Thanks to its three-color LED, the equipment can activate the optimum transmitter light
source for every contrast. Additionally, it has an especially accurate, static Teach-in
procedure. The gray values of the mark to be detected are taught-in sepa-
rately here either via the Teach-in button on the equipment or an
external control wire. The scanner sets the ideal switching
threshold from the two determined gray values.
The high precision of the contrast detection,
automatic shine adjustment with material
to be scanned with high reflectance, scan-
ning distances of 10 mm, 20 mm and 40
mm, switching sequence of 10 kHz and in-
dividual alignment and attachment options
cover numerous tasks in which it is a ques-
tions of brilliant detection results.
C
o
n
t
r
a
s
t

S
c
a
n
n
e
r
s

K
T
5
W
-
2
_
_
_
6
2 SI CK 2007- 09- 05
2007- 09- 05 SI CK 3
N
o
t
e
s
S
t
a
t
u
s
T
e
a
c
h
-
i
n
:

s
e
t
t
i
n
g

s
w
i
t
c
h
i
n
g

t
h
r
e
s
h
o
l
d
KT5W-2_ _ _6
RUN
T
E
A
C
H
RUN
T
E
A
C
H
Q
Light-/dark-switching not required: equipment switches for the material to be scanned,
which was under the light spot at the first Teach-in procedure (mark or background).
The material speed must be zero during Teach-in (machine is idle).
The Teach-in button can be locked against unintentional activation with Run.
A Teach-in procedure can be triggered when the switch setting is not defined.
After the first Teach-in procedure, the red transmitter light and
the status indicator blink and signal that a second Teach-in
procedure must be triggered.
The optimum transmission light was selected automatically.
Q
ET L+
or
ET L+
+
ET L+
or
ET L+
+
Switching threshold Switching threshold
Internal
analogue signal Q
A
Output Q Output Q
Internal
analogue signal Q
A
4 SI CK 2007- 09- 05
RUN
T EACH
Q
T
E
A
C
H
6
7
5
80 16
52
28 13
3.5
2
5
4
0
5
3
3
0
.
4
2
1
3
28
56
9
5
M
M
5
3
1
2
2
4
C
U
V
Static Teach-in to mark and back-
ground via control cable or control
panel on unit
Automatic switching threshold
adjustment for detection of
extremely shiny objects
Switching frequency 10000/s
Light source red, green, blue
Dimensional drawing

Cables and connectors

Mounting systems

Lens

3

1
All types
All types
Adjustments possible Lens (light transmission), can be replaced by item
M5 mounting holes, 5.5 mm deep
Blind screw, can be replaced by item
5-pin, M12 x 1 plug (rotatable through 90)
Function signal indicator (yellow)
Pre-selection switch
Teach-in button
7
6
5
4
3
2
1
Connection type

Accessories
KT5W-2_ _ _6 Contrast scanners
Scanning distance
10/20/40 mm
Contrast scanners

KT5W-2P1116

KT5W-2P1126

KT5W-2P1316

KT5W-2N1316

2
5
.
5
3.5

KT5W-2P1216

KT5W-2N1216
4.5

2
5
.
6
17.4

2
6

KT5W-2B1116

5-pin, M12 x 1
1
L+
Q
M
NC
ET
4
3
2
5
brn
blk
blu
wht
gra
ON

KT5W-2P1116

4-pin, M12 x 1
1
L+
Q
P
M
Q
N
4
3
2
brn
blk
blu
wht
ON

KT5W-2N1116

KT5W-2P1126

KT5W-2P1216

KT5W-2P1216

KT5W-2B1116

KT5W-2N1316
2007- 09- 05 SI CK 5

KT5W-2P1126
1)
Average service life 100,000 h at
T
A
= + 25 C
2)
Limit values
5)
Signal transit time with resistive load
6)
Reference voltage 32 V DC
3)
May not exceed or fall short of
V
S
tolerances
4)
Without load
7)
A = V
S
connections reverse-polarity
protected
B = Outputs short-circuit protected
C = Interference pulse suppression

1018587

KT5W-2P1216

1018586

KT5W-2P1316

1018961

KT5W-2N1116

1018045

KT5W-2N1216

1019022

KT5W-2N1316

1022678

Technical data KT5W-2

P1116

P1126

P1216

P1316

N1116

N1216

N1316

B1116


KT5W-2P1116

1018044
Order no. Preferred type
*)

Order information
Scanning distance 10 3 mm
from front edge of lens 20 3 mm
40 3 mm
Light spot dimensions 1.2 x 4.2 mm
1.5 x 5.5 mm
1.1 x 4.2 mm
Light source
1)
; light type; LED; red, blue, green;
Wavelength (nm) 640, 525, 470
Supply voltage V
S
10... 30 V DC
2)
Residual ripple
3)
< 5 V
PP
Current consumption
4)
< 80 mA
Switching outputs PNP: HIGH = V
S
< 2 V / LOW = 0 V
NPN: HIGH = V
S
/ LOW = < 2 V
Output current I
A
max. 100 mA short-circuit protected
Response time
5)
; switching frequency 50 s; 10000/s
Time delay No timing element
Deactivation delay, ... 20 ms
Teach-in input ET PNP: Teach > 10 V...< V
S
Run 0 V or unswitched
NPN: Teach 0 V
Run V
S
or unswitched
Retention time 25 ms non-volatile memory
Connection type Plug 4-pin, M12
Plug 5-pin, M12
VDE protection class
6)
V
Enclosure rating IP 67
Circuit protection
7)
A, B, C
Ambient temperature T
A

Operation 10 ... +55 C
Storage 25 ... +75 C
Shock load To IEC 68
Weight Approx. 400 g
Housing Cast zinc
KT5W-2_ _ _6

Scanning distance 40 mm 3

Scanning distance 20 mm 2

Scanning distance 10 mm 1
Scanning distance
1
3
2
(mm) 10 20 30 40 50
100
90
80
70
60
50
40
30
20
10
0
R
e
l
a
t
i
v
e

s
e
n
s
i
t
i
v
i
t
y

i
n

%*)
Further types on request

KT5W-2B1116

1043006