MP

STANDARD ORIFICES

The law of continuity of flow reads:


If a process fliud flows through a piping, that flow is equal at every cross-section of the piping regardless of its diameter. If
there is a constriction in the piping, the velocity of flow at that point will increase because the same quality of fluid must flow
through in the unit of time as at the point of the larger cross-section. Further, in conformity with the law of conservation of energy
(Bernouille theorem), the energy consisting of the sum of the kinetic energy (velocity) and the static pressure must be constant
at such a point. The consequence is that if the velocity of flow is increased in the area of constriction (increase of the kinetic
energy), the static pressure energy must decrease in the same amount to obtain an equal sum of both these energies. A drop
of the static pressure is called the differential pressure. By mathematical derivation from these two theorems we arrive at an
expression for the flow in dependance on the differential pressure at the construction area (orifice):

q = c .

p ,

where

q - mass or volume (qm, qv) flow


p - differenttial pressure
c - the constant depends on the orifice configuration

and the process fluid characteristic

STANDARD ORIFICES WITH ANNULAR CHAMBERS TO DIN STANDARDS

Basic construction characteristics and use:


- very accurate measurement is achived by an annular chamber with corner tapping at 6 points because
by this method is measured the mean value of differential pressure:
- suitable for measurement of process fluid velocities below 40 m/s
- for 5 .10 3

Re

,
10 7 (Reynold s number)

- with orifices having rated pressure PN 64 and PN


100 expensive grooved packing for flanged connections are not required because gasket grooves enable the installation of It-gaskets
- very simple replacement of orifice plates in operation;
- calculation of orifice bore to DIN 1952 and ISO
5167.
Construction configuration to DIN 1952, DIN 19205
and ISO 5167, for liquids, vapors and gases.

Use:

Overall lengh:

For non-corrosive service and temperatures:


Orifice plate material:

up to 400OC
W.-Nr.1.4541

Carrier ring material:


Gasket material:

W.-Nr.1.0402
It

65 mm

Nominal pipes size:

DN 50 to DN 500

Rated pressure:

PN 16 to PN 100

ATM supplies orifices with 2 flange gasket. Flanges


and bolts are not in the delivery.

ATM Ltd.

+385 1 2499 410

+385 1 2499 420

Angle between pressure tappings:


Pressure tappings connection:
Flanges
Gasket grooves
info@atm.hr

0O, 90O, 180O


G 1/2 to DIN 19207 FORMV

to DIN 2633-DIN 2637


to DIN 2512 (only for PN64 / PN100)
MP_ae2

61

STANDARD ORIFICE WITH ANNULAR


CHAMBERS TO DIN STANDARDS

MP

DIMENSIONS

PN 16
PN 25
PN 40

PN 64
PN 100

Pipe size
a
b
NP 16
NP 25
c
NP 40
NP 64
NP 100
NP 16
NP 25
d
NP 40
NP 64
NP 100
e
h
f

DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 175 DN 200 DN 250 DN 300 DN 350 DN 400 DN 500
2

85

104

116

140

166

195

224

248

304

357

411

462

575

302

322

338

358

388

412

442

468

520

578

550

690

810

448

478

535

595

650

705

815

302

322

338

362

388

418

460

485

545

610

665

735

815

302

322

338

362

388

418

460

485

545

610

665

735

302

322

338

362

388

418

460

485

545

610

665

102

122

138

158

188

212

242

268

320

378

438

490

610

248

278

335

395

450

505

615

102

122

138

162

188

218

260

285

345

410

465

535

615

102

122

138

162

188

218

260

285

345

410

465

535

102

122

138

162

188

218

260

285

345

410

465

72

94

105

128

154

182

212

238

291

342

394

446

548

89

110

121

150

176

204

234

260

313

364

422

474

576

2.5

2.5

2.5

3.5

3.5

3.5

ORDERING DATA
R ated pressure 16
P ip e
DN

50
50
65
80
100
100
125
125
150
150
175
200
250
250
300
350
350
400
400
500

51.2
54.5
70.3
82.5
100.8
107.1
125
131.7
150
159.3
182.9
207.3
254.4
260.4
309.7
339.6
352
390.4
403
492

C ode-N o.
39.21.515
39.21.516
39.21.517
39.21.518
39.21.519
39.21.520
39.21.521
39.21.522
39.21.523
39.21.524
39.21.525
39.21.526
39.21.527
39.21.528
39.21.529
39.21.530
39.21.531
39.21.532
39.21.533
39.21.534

R ated pressure 25
P ip e
DN

175
200
250
250
300
350
350
400
400
500

182.9
206.3
252.8
258.8
307.9
339.6
352
388.8
401.4
488

C ode-N o.

39.21.545
39.21.546
39.21.547
39.21.548
39.21.549
39.21.550
39.21.551
39.21.552
39.21.553
39.21.554

R ated pressure 40
P ipe
DN
50
50
65
80
100
100
125
125
150
150
175
200
250
250
300
350
350
400
400
500

D
51.2
54.5
70.3
82.5
100.8
107.1
125
131.7
150
159.3
182.9
206.5
252.8
258.8
307.9
338
350.4
384.4
397
479.6

C ode-N o.
39.21.555
39.21.556
39.21.557
39.21.558
39.21.559
39.21.560
39.21.561
39.21.562
39.21.563
39.21.564
39.21.565
39.21.566
39.21.567
39.21.568
39.21.569
39.21.570
39.21.571
39.21.572
39.21.573
39.21.574

R ated pressure 64
P ipe
DN
50
50
65
80
100
100
125
125
150
150
175
200
250
250
300
350
350
400
400

D
51.2
54.5
69.7
81.7
100
106.3
124
130.7
147.8
157.1
181.1
204.9
249.4
255.4
301.9
330.6
343
378
390.6

C ode-N o.
39.21.575
39.21.576
39.21.577
39.21.578
39.21.579
39.21.580
39.21.581
39.21.582
39.21.583
39.21.584
39.21.585
39.21.586
39.21.587
39.21.588
39.21.589
39.21.590
39.21.591
39.21.592
39.21.593

R ated pressure 100


P ipe
DN
50
50
65
80
100
100
125
125
150
150
175
200
250
250
300

D
50.6
53.9
68.9
80.9
98
104.3
120.4
127.1
144.8
154.1
176.1
199.1
242
248
295.5

C ode-N o.
39.21.594
39.21.595
39.21.596
39.21.597
39.21.598
39.21.599
39.21.600
39.21.601
39.21.602
39.21.603
39.21.604
39.21.605
39.21.606
39.21.607
39.21.608

NOTE: Before placing an order for orifices or orifice plates kindly fill up
ATM Flow Measurement Questionnaire.
ATM Ltd.

+385 1 2499 410

+385 1 2499 420

info@atm.hr

MP_ae2

62

MP

ORIFICE FLANGE UNIONS TO ASA STANDARDS TYPE RF

DIMENSIONS AND ORDERING DATA

Pipe
E

G
40.9

48.3

60.4

88.9

114.3

168.3
DN

A
mm

B
mm

R a te d p re ss u re A N S I 3 0 0 lb R F

C
mm

D
mm

F = 1 .6 m m

1 1 /2 "

156

3 8 .1

86

70

2"

165

3 8 .1

86

84

3"

210

3 8 .1

89

118

4"

254

3 8 .1

92

146

6"

318

3 8 .1

102

206

219.0

273.0

3.7

DN

Code-No.

SCH

300 lb

600 lb

40

39.22.551

39.22.587

38.1

5.1

80

39.22.552

39.22.588

34

7.15

160

39.22.553

39.22.589

52.5

3.95

40

39.22.554

39.22.590

49.2

5.6

80

39.22.555

39.22.591

1 1/2"

2"

42.8

8.8

160

39.22.556

39.22.592

77.9

5.5

40

39.22.557

39.22.593

73.6

7.65

80

39.22.558

39.22.594

3"

66.6

11.15

160

39.22.559

39.22.595

102.3

6.0

40

39.22.560

39.22.596

97.2

8.55

80

39.22.561

39.22.597

87.3

13.5

160

39.22.562

39.22.598

154

7.15

40

39.22.563

39.22.599

146.3

11.0

80

39.22.564

39.22.600

131.7

18.3

160

39.22.565

39.22.601

202.7

8.15

40

39.22.566

39.22.602

193.7

12.65

80

39.22.567

39.22.603

173

23.0

160

39.22.568

39.22.604

254.5

9.25

40

39.22.569

39.22.605

242.9

15.05

80

39.22.570

39.22.606

4"

6"

8"

10"

8"

381

4 1 .3

111

260

215.9

28.55

160

39.22.571

39.22.607

10"

444

4 7 .6

117

321

303.2

10.3

40

39.22.572

39.22.608

12"

521

5 0 .8

130

375

14"

584

54

143

425

289

17.4

80

39.22.573

39.22.609

16"

647

57

146

482

257.2

33.3

160

39.22.574

39.22.610

18"

711

6 0 .5

159

533

333.3

11.15

40

39.22.575

39.22.611

20"

774

6 3 .5

162

587

323.8

355.6
DN

A
mm

B
mm

Rated pressure ANSI 600lb RF

C
mm

D
mm

F = 6.4 mm

1 1/2"

156

38.1

86

70

2"

165

38.1

86

84

3"

210

38.1

89

118

4"

273

44.5

108

152

6"

356

54

124

222

8"

419

62

140

273

10"

508

70

159

343

12"

559

73

162

400

ATM Ltd.

+385 1 2499 410

+385 1 2499 420

406.4

457.2

508.0

info@atm.hr

12"

317.5

19.05

80

39.22.576

39.22.612

284.2

35.7

160

39.22.577

39.22.613

381

12.7

40

39.22.578

39.22.614

363.5

21.45

80

39.22.579

39.22.615

14"

16"

325.4

40.5

160

39.22.580

39.22.616

428.6

14.3

40

39.22.581

39.22.617

409.5

23.85

80

39.22.582

39.22.618

18"

366.7

45.25

160

39.22.583

39.22.619

477.8

15.1

40

39.22.584

39.22.620

455.6

26.2

80

39.22.585

39.22.621

408

50

160

39.22.586

39.22.622

20"

MP_ae2

63

ORIFICE FLANGE UNION TO ASA STANDARDS TYPE RF

MP

Type Flange Taps manufactured to ANSI B 16.5 and


A.G.A. Report No.3.
Flange type: Welding Neck
Nominal pipe size 1 1/2 to 20
Rated pressure (class): 300 lb to 600 lb
Use: non-corrosive service and temperatures up to 400 0C
Flange material: W.Nr. 1.042
Stud material: W.Nr. 1.7225
Nut material: W.Nr. 1.0501
Gasket material (
= 1,5 mm) Tesnit unit
Orifice plate material: W.Nr. 1.4541
Plug material: W.Nr. 1.0501
Pressure tapping: 1/2 - 14 NPT
Studs dimensions to ASA B1.1 with rolled thread
along the entire shank
ORIFICE PLATE
FOR ORIFICES - FLANGE UNIONS TO
ASA STANDARDS - TYPE RF

For flow measurement of liquids, gases and steam.


Manufactured to ASA standards:ISA RP3.2, ASME PTC 19.5
For orifice flange-unions to ANSI B 16.36 or ANSI B 16.5
RF, type Welding Neck and Slip on
Nominal width 1 1/2 to 20
Rated pressure 300 lb and 600 lb
For non-corrosive and corrosive service:
Material: W.Nr. 1.4541
D - drain hole on request
V - vent hole on request
f - piping ID to be specified by buyer
Construction features:
- concentric orifice plate bore
- manifactured to A. G. A. Report No. 3
- stamped: bore diameter d, pipe ID D,
material, Tag No and inlet.
Also available:
- quarter circle orifice plate
- concial entrance orifice plate
- flow in both directions
- corrosive service
- other nominal sizes and rated pressures.

Pipe size
a( 350C)
150 lb
a
300 lb
600 lb
150 lb
b
300 lb
600 lb
150 lb
c
300 lb
600 lb

ATM Ltd.

11/2"
3
85,7
95,3
95,3
70
88
88
30
30
30

2"
3
104,8
111,1
111,1
70
88
88
30
30
30

3"
3
136,5
149,2
149,2
70
88
88
30
30
30

+385 1 2499 410

4"
3
174,6
181,0
193,7
81
100
100
30
30
30

6"
3
222,3
250,8
266,7
81
100
100
40
40
40

8"
3
279,4
308,0
320,7
81
100
114
40
40
40

+385 1 2499 420

10"
6
339,7
362,0
400,1
81
100
114
40
40
40

12"
6
409,6
422,3
457,2
88
114
114
40
40
40

14"
6
450,8
485,8
492,1
88
114
114
40
40
50

info@atm.hr

16"
9
513,4
539,8
565,2
88
114
127
40
40
50

18"
9
549,3
596,9
612,8
100
127
127
40
40
50

20"
9
606,4
654,1
682,6
114
127
127
40
40
50

For temperaturs above 315 0C,


thickness
a
increasses
acording to ASME PTC 19.5
NOTE: Before placing an order
for orifices or orifice plates kindly
fill up ATM Flow Measurement
Questionnaire.

MP_ae2

64

ORIFICE FLANGE UNIONS TO ASA STANDARDS TYPE RJ

MP

Type Flange Taps manufactured to


ANSI B 16.5 and A. G. A. Report No 3.
Flange type Welding Neck.
Nominal size 1 to 20.
Rated class: 300lb and 600lb (other classes on request).
Use: non-corrosive service and
temperatures up to 400C.
Flange material: W.Nr.1.0402.
Stud material: W.Nr.1.7225.
Nut material: W.Nr.1.0501.
Orifice plate holder material: W.Nr.1.0501.
Orifice plate material: W.Nr.1.4541.
Plug material: W.Nr.1.0501.
Pressure tapping: - 14 NPT F.
Studs dimensions to ASA B1.1 with
rolled thread along the entire shank.
DN

A
mm

B
mm

C
mm

D
mm

F
mm

Rated pressure ANSI 300 lb RJ


1 1/2"

156

42.9

90.7

70

6.4

2"

165

44.4

92.2

84

7.9

3"

210

44.4

95.2

117

7.9

4"

254

44.4

98.2

146

7.9

6"

318

44.4

106.4

206

7.9

8"

381

47.4

117.6

260

7.9

10"

444

54.1

123.6

320

7.9

12"

521

57.1

136.3

375

7.9

14"

584

60.1

149

425

7.9

16"

648

63.5

152.3

483

7.9

18"

711

66.8

165.1

533

7.9

20"

775

71.4

170

587

9.5

E
G

Rated pressure ANSI 600 lb RJ

ATM Ltd.

+385 1 2499 410

+385 1 2499 420

info@atm.hr

1 1/2"

156

44.5

92.3

70

6.4

2"

165

46

93.8

84

7.9

3"

210

46

96.8

118

7.9

4"

273

46

109.5

152

7.9

6"

356

55.7

125.2

222

7.9

8"

419

63.5

141.3

273

7.9

10"

508

71.4

160.3

343

7.9

12"

559

74.4

163.3

400

7.9

14"

603

77.8

173

432

7.9

16"

686

84.1

185.7

495

7.9

18"

743

90.5

192.1

546

7.9

20"

813

98.4

200

610

9.5

MP_ae2

65

ORIFICE FLANGE UNION TO ASA STANDARDS TYPE RJ

MP

DIMENSIONS AND ORDERING DATA

Pipe
E

48.3

60.4

88.9

114.3

168.3

219.0

273.0

323.8

355.6

406.4

457.2

508.0

ATM Ltd.

+385 1 2499 410

DN

SCH

40.9

3.7

40

38.1

5.1

80

1 1/2"

Code No.
300 lb

600 lb

39.23.551

39.23.587

39.23.552

39.23.588

34

7.15

160

39.23.553

39.23.589

52.5

3.95

40

39.23.554

39.23.590

49.2

5.6

80

39.23.555

39.23.591

42.8

8.8

160

39.23.556

39.23.592

77.9

5.5

40

39.23.557

39.23.593

73.6

7.65

80

39.23.558

39.23.594

2"

3"

66.6

11.15

160

39.23.559

39.23.595

102.3

6.0

40

39.23.560

39.23.596

97.2

8.55

80

39.23.561

39.23.597

87.3

13.5

160

4"

39.23.562

39.23.598

154

7.15

40

39.23.563

39.23.599

146.3

11.0

80

39.23.564

39.23.600

131.7

18.3

160

39.23.565

39.23.601

202.7

8.15

40

39.23.566

39.23.602

193.7

12.65

80

39.23.567

39.23.603

173

23.0

160

39.23.568

39.23.604

254.5

9.25

40

39.23.569

39.23.605

39.23.570

39.23.606

39.23.571

39.23.607

39.23.572

39.23.608

39.23.573

39.23.609

39.23.574

39.23.610

39.23.575

39.23.611

39.23.576

39.23.612

39.23.577

39.23.613

39.23.578

39.23.614

39.23.579

39.23.615

242.9

15.05

80

215.9

28.55

160

303.2

10.3

40

289

17.4

80

257.2

33.3

160

333.3

11.15

40

317.5

19.05

80

284.2

35.7

160

381

12.7

40

363.5

21.45

80

6"

8"

10"

12"

14"

16"

325.4

40.5

160

39.23.580

39.23.616

428.6

14.3

40

39.23.581

39.23.617

409.5

23.85

80

39.23.582

39.23.618

366.7

45.25

160

39.23.583

39.23.619

477.8

15.1

40

39.23.584

39.23.620

455.6

26.2

80

39.23.585

39.23.621

408

50

160

39.23.586

39.23.622

+385 1 2499 420

18"

20"

info@atm.hr

MP_ed2

66

ORIFICE FLANGE UNION TO ASA STANDARDS TYPE RJ

MP

ORIFICE PLATE
For flow measurement of liquids, gases and steam.
Manufactured to ASA standards ISA RP3.2, ASME PTC 19.5.
For orifice flange unions to ANSI B 16.36 or ANSI B 16.5 RJ, type ''Welding Neck'' and ''Slip on''.
Nominal width 1 1/2" to 20", rated pressure 300 lb and 600 lb, material W.Nr.1.4541.
For non-aggressive and aggressive media.
Construction features of standard orifice plate:
- concentric orifice plate bore
- manufactured to A. G. A. Report No. 3.
- stamped bore diameter ''d'', pipe ID ''D u '', material, Tag No and ''inlet''.

FOR ORIFICE FLANGE UNIONS TO ASA STANDARDS TYPE RJ

W=3.18

4.8

4.8

0'

0'

0'

4.8

23 3

23 3

23 3
W
L

D0 - "Welding neck"
D1 - "Slip on"

K - "Welding neck"
K1 - "Slip on"

BB

D0 - "Welding neck"
D1 - "Slip on"

BB

W=6.4

a)

b)

c)
D u- inner pipe diameter
S - pipe wall thickness
D v - outer pipe diameter

a) Orifice plate for flanges under 3"


b) Orifice plate with holder for flanges from 4" to 6"
c) Orifice plate with holder for flanges over 8"

ATM Ltd.

255.6
309.6
353.5
401.6
452.4
515.9
565.2

3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
6.4
6.4
6.4

0.8
0.8
0.8
1.6
1.6
3.2
3.2
3.2
3.2
6.4
6.4
6.4

K1

P
68.3
82.6
123.8
149.2
211.1
269.9
323.9
381.0
419.1
469.9
533.4
584.2

+385 1 2499 410

H
300 600
25.4
27.0
27.0
26.2 27.0
26.2 27.0
26.2 27.0
26.2 27.0
26.2 27.0
26.2 27.0
27.8 28.6
27.8 28.6
29.4 30.2

C
5.4
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
8.7

L
300 600
11.1
11.9
11.9
14.7 15.1
14.7 15.1
14.7 15.1
14.7 15.1
14.7 15.1
14.7 15.1
16.3 16.7
16.3 16.7
17.1 17.5

+385 1 2499 420

M
300

600

11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
12.3

11.9
11.9
11.9
11.9
11.9
11.9
11.9
11.9
12.7

info@atm.hr

D0 D1

D 0 = D U+ 0.79

134.9
196.9
253.6
307.6
359.6
379.7
448.5
512.0
561.2

D 1=(D V-1%)-2(S+15%)+0.79

1 1/2
2
3
4
6
8
10
12
14
16
18
20

K = D U- 1.59

BB

K 1 =(D V -1%)-2(S+15%)-1.59

For orifice plate code number to the code number of orifice flange union the number 801 will be added
(for example 3'' 600 SCH 80 - 39.23.594-801).
D / V - drain / vent hole on request
G
300 600
90
90
90
100 110
120 140
120 140
125 185
165 185
180 185
180 200
180 200
190 210

For temperatures above 315C thickness


a increases according to ASME PTC 19.5
Also available:
- quarter circle orifice plate
- for aggressive media;
- for other nominal sizes and
rated pressures.
NOTE: Before ordering kindly fill up