You are on page 1of 28

3PAR Host Explorer 1.1.

0 Users
Guide
3PAR Inc.
4209 Technology Drive
Fremont, CA 94538 USA
320-200132 Rev A
October 2009
Revision Notice
This is the first release of this manual. A complete revision history is provided at the end of this document.
Changes
The material in this document is for information only and is subject to change without notice. While reasonable efforts have been
made in the preparation of this document to assure its accuracy, 3PAR Inc. assumes no liability resulting from errors or omissions in
this document or from the use of the information contained herein.
3PARdata reserves the right to make changes in the product design without reservation and without notification to its users.
Updates to the Documentation at 3PAR Central
Any updates to this document, or to other 3PAR technical documents, can be found by logging on to 3PAR Centrals Document
Control System from 3PARs Support page at http://www.3par.com/support/index.html
3PAR Technical Support and Services
Contact your local service provider for technical support and services.
Sales and Ordering Information
For sales and ordering information, contact:
3PAR Inc.
4209 Technology Drive
Fremont, CA 94538 USA
Telephone: 510-413-5999
Fax: 510-413-5699
Email: salesinfo@3PAR.com
Reader Comments and Suggestions
Please email your comments and suggestions about this document to ReaderComments@3PAR.com.
Copyrights
2009 PAR Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any
form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of 3PAR Inc.,
4209 Technology Drive, Fremont, CA 94538. By way of exception to the foregoing, the user may print one copy of electronic material
for personal use only.
Trademarks
3PAR, InServ, InForm, InSpire and Serving Information are registered trademarks of 3PAR Inc.
Microsoft, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation.
UNIX is a registered trademark of The Open Group.
All other trademarks and registered trademarks are owned by their respective owners.
Federal Communications Commission Radio Frequency Interference Statement
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users
authority to operate the equipment.
This device complies with Part 15 of FFC Rules. Operation is subjected to the following two conditions (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.
iii Table of Contents
3PAR Host Explorer Users Guide
Table of Contents
1 Introduction
1.1 Overview 1.2
1.2 Audience 1.2
1.3 Related Documentation 1.3
1.4 Organization 1.3
1.5 Typographical Conventions 1.4
1.6 Advisories 1.4
2 Overview
2.1 The 3PAR Host Explorer 2.1
3 Installation and Deinstallation
3.1 Overview 3.2
3.2 Installation and Verification 3.2
3.2.1 Installing a 3PAR Host Explorer Agent on Microsoft Windows Server Systems 3.3
3.2.2 Verifying the Installation on Microsoft Windows Server 3.3
3.2.3 Installing a 3PAR Host Explorer Agent on Red Hat Linux Systems 3.3
3.2.4 Verifying the Installation on Red Hat Linux Systems 3.4
3.2.5 Installing a 3PAR Host Explorer Agent on Solaris Sparc Systems 3.4
3.2.6 Verifying the Installation on Solaris Sparc Systems 3.4
iv Table of Contents

3PAR Host Explorer Users Guide
3.3 Deinstallation 3.5
3.3.1 Deinstalling a 3PAR Host Explorer Agent on Microsoft Windows Server 3.5
3.3.2 Deinstalling a 3PAR Host Explorer Agent on Red Hat Linux Systems 3.5
3.3.3 Deinstalling a 3PAR Host Explorer Agent on Solaris Sparc Systems 3.5
4 Using the Host Explorer
4.1 Overview 4.2
4.2 Verifying the 3PAR Host Explorer Package is Installed 4.2
4.3 Verifying the 3PAR Host Explorer Process is Running 4.2
4.4 Stopping the 3PAR Host Explorer Process 4.2
4.5 Starting the 3PAR Host Explorer Process 4.3
4.6 Supporting Multiple InServ Storage Servers on a Single Host 4.3
4.7 Supporting VMware Virtual Machines with iSCSI 4.3
4.8 The 3PAR Host Explorer Enclosure Device LUN 4.3
4.8.1 InServ Storage Server Upgrades and Enclosure Devices 4.4
5 TpdHostAgent Command
5.1 Overview 5.1
5.2 TpdHostAgent Command 5.2
RH Revision History
3PAR Host Explorer Users Guide
1.1 Introduction
1
Introduction
In this chapter
1.2 Audience 1.2
1.3 Related Documentation 1.3
1.4 Organization 1.3
1.5 Typographical Conventions 1.4
1.6 Advisories 1.4
1.2
Overview
3PAR Host Explorer Users Guide
1.1 Overview
This guide provides information for installing and deinstalling a 3PAR Host Explorer on the
following platforms:
Microsoft Windows Server 2003 and 2008, 32 bit and 64 bit
Red Hat Linux systems running RHEL4 Update 6 or later and RHEL5
Sparc systems running Solaris 10
Also, this guide provides reference information on the CLI utility TpdHost Agent , which allows
management of the 3PAR Host Explorer on the hosts.
1.2 Audience
This guide is for Microsoft Windows, Red Hat Linux, and Solaris Sparc administrators who are
responsible for maintaining the operating environment and who understand the InServ
Storage Server.
NOTE: For information about supported platforms refer to the 3PAR InForm OS
2.3.1 Configuration Matrix, available from 3PARs Document Control System.
1.3
Related Documentation
3PAR Host Explorer Users Guide
1.3 Related Documentation
The following documents also provide information related to InServ Storage Servers and the
InForm Operating System:
1.4 Organization
This guide is organized as follows:
Chapter 1, Introduction (this chapter), provides an overview of this guide, including
information on audience, related documentation, and typographical conventions.
Chapter 2, Overview, provides an overview of the 3PAR Host Explorer program.
Chapter 3, Installation and Deinstallation, describes how to install, verify, and uninstall the
3PAR Host Explorer on Windows Server 2003 and 2008, Red Hat Linux, and Solaris Sparc
operating systems.
Chapter 4, Using the Host Explorer, describes procedures to stop, start and refresh the 3PAR
Host Explorer.
For information about Read the
InServ Storage Server concepts and
terminology
3PAR InForm OS Concepts Guide
Detailed CLI command descriptions and
usage
3PAR InForm Command Line Interface Reference
Using the InForm Command Line Interface
(CLI) to configure and administer InServ
Storage Servers
3PAR InForm OS CLI Administrators Manual
Using the InForm Management Console to
configure and administer InServ Storage
Servers
3PAR InForm OS Management Console Online Help
1.4
Typographical Conventions
3PAR Host Explorer Users Guide
Chapter 5, TpdHostAgent Command, provides reference information for the
TpdHost Agent command, a utility for management of the 3PAR Host Explorer on the
host.
This guide also contains a revision history describing the major changes for each version.
1.5 Typographical Conventions
This guide employs the following typographical conventions:
1.6 Advisories
To avoid injury to people or damage to data and equipment, be sure to observe the cautions
and warnings in this guide.
Typeface Meaning Example
ABCDabcd Used for dialog elements
such as titles, button labels,
and other screen elements.
When prompted, click Finish to
complete the installation.
ABCDabcd Used for paths, filenames,
and screen output.
Open the file
\ gui \ wi ndows\ set up. exe
<ABCDabcd> Used for variables in
filenames, paths, and
screen output.
Modify the content string by adding the -
P <var i abl e>option after - j ar
i nf or m. j ar
NOTE: Notes are reminders, tips, or suggestions that supplement the procedures
included in this guide.
3PAR Host Explorer Users Guide
2.1 Overview
2
Overview
In this chapter
2.1 The 3PAR Host Explorer 2.1
2.1 The 3PAR Host Explorer
The 3PAR Host Explorer is a program that runs on a host connected to an InServ Storage Server.
The Host Explorer is an agent that runs as a service on Windows and as a daemon on Linux and
Solaris operating systems. No license is required to use the 3PAR Host Explorer.
The Host Explorer communicates with the storage server over an FC or iSCSI connection and
enables the host to send detailed host configuration information to the storage server. The
information gathered from the Host Explorer is visible for uncreated hosts and assists with host
creation and diagnosing host connectivity issues.
When a host is created on the InServ Storage Server, unassigned WWNs or iSCSI names are
presented to the storage server. Without the Host Explorers running on the attached hosts,
the storage server is unable to determine which host the WWN or iSCSI names belongs to and
you must manually assign each WWN or iSCSI name to a host. With Host Explorers running, the
InServ Storage Server automatically groups WWNs or iSCSI names for the host together,
assisting with creating the host.
The Host Explorer collects the following information and sends it to the storage server:
Host operating system and version.
2.2
The 3PAR Host Explorer
3PAR Host Explorer Users Guide
Fibre Channel and iSCSI HBA details.
Multipath driver and current multipath configuration.
Cluster configuration information.
Device and path Information.
See Chapter 3, Installation and Deinstallation to install the 3PAR Host Explorer. Refer to the
3PAR InForm OS 2.3.1 Configuration Matrix for a list of supported host operating systems.
3PAR Host Explorer Users Guide
3.1 Installation and Deinstallation
3
Installation and
Deinstallation
In this chapter
3.1 Overview 3.2
3.2 Installation and Verification 3.2
3.2.1 Installing a 3PAR Host Explorer Agent on Microsoft Windows Server Systems 3.3
3.2.2 Verifying the Installation on Microsoft Windows Server 3.3
3.2.3 Installing a 3PAR Host Explorer Agent on Red Hat Linux Systems 3.3
3.2.4 Verifying the Installation on Red Hat Linux Systems 3.4
3.2.5 Installing a 3PAR Host Explorer Agent on Solaris Sparc Systems 3.4
3.2.6 Verifying the Installation on Solaris Sparc Systems 3.4
3.3 Deinstallation 3.5
3.3.1 Deinstalling a 3PAR Host Explorer Agent on Microsoft Windows Server 3.5
3.3.2 Deinstalling a 3PAR Host Explorer Agent on Red Hat Linux Systems 3.5
3.3.3 Deinstalling a 3PAR Host Explorer Agent on Solaris Sparc Systems 3.5
3.2
Overview
3PAR Host Explorer Users Guide
3.1 Overview
This chapter describes how to install, verify, and deinstall the 3PAR Host Explorer agent on the
following platforms:
Microsoft Windows Server 2003 and 2008, 32 bit and 64 bit
Red Hat Linux systems running RHEL4 Update 6 or later and RHEL5
Sparc systems running Solaris 10
3.2 Installation and Verification
This section describes how to install and verify installation of a 3PAR Host Explorer agent. You
must have the 3PAR Host Explorer CD, part number 780-200053 to install the 3PAR Host
Explorer.
NOTE: For information about supported platforms, refer to the InForm OS
Configuration Matrix available from 3PARs Document Control System.
NOTE: In order for the InServ Storage Server to dynamically discover host devices,
you must follow specific configuration instructions for the host operating system
and HBA. See the 3PAR Implementation Guides for recommended practices and
detailed configuration information about using your specific host devices with
the InServ Storage Server.
NOTE: Each host connected to the InServ Storage Server must use a host persona
with the SCSI Enclosure Services LUN (SESLun) enabled, or the Host Explorer agent
cannot communicate with the InServ Storage Server. If you upgraded to 3PAR
InForm Operating System version 2.3.1 from a previous release, you must convert
your legacy personas to new host personas. For information about configuring
host personas, see the 3PAR InForm OS CLI Administrators Manual or the 3PAR
InForm OS Management Console Online Help.
3.3
Installation and Verification
3PAR Host Explorer Users Guide
3.2.1 Installing a 3PAR Host Explorer Agent on Microsoft Windows Server
Systems
To install a 3PAR Host Explorer agent on a Microsoft Windows Server 2003 or 2008 system:
1 Log into the host as the System Administrator.
2 Insert the 3PAR Host Explorer CD into a CD-ROM drive.
3 Open a Windows Explorer window.
4 Select Start > All Programs > Accessories > Windows Explorer.
5 Double-click the CD-ROM drive to expand the files.
6 Double-click the appropriate file:
For x86-32 platforms: Host Expl or er X86. msi
For x86-64-bit platforms: Host Expl or er X64. msi
3.2.2 Verifying the Installation on Microsoft Windows Server
To verify the 3PAR Host Explorer agent installation for the Microsoft Windows Server 2003 or
2008 system:
1 Log on as the System Administrator.
2 Select Start > Control Panel > Add/Remove Programs.
Result: The Add/Remove Programs window appears.
3 Verify 3PAR Host Explorer for Windows appears under the Currently installed
programs column.
3.2.3 Installing a 3PAR Host Explorer Agent on Red Hat Linux Systems
To install a 3PAR Host Explorer agent on a Red Hat Linux system:
1 Log on as the root user.
2 Insert the 3PAR Host Explorer CD into a CD-ROM drive.
3 Change directory to the CD-ROM drive.
3.4
Installation and Verification
3PAR Host Explorer Users Guide
4 Issue the following command:
3.2.4 Verifying the Installation on Red Hat Linux Systems
Verify the 3PAR Host Explorer agent installation for the Red Hat Linux system:
1 Log on as the System Administrator.
2 Issue the following command:
3.2.5 Installing a 3PAR Host Explorer Agent on Solaris Sparc Systems
To install a 3PAR Host Explorer agent on a Solaris Sparc system:
1 Log in as the root user.
2 Insert the 3PAR Host Explorer CD into a CD-ROM drive.
3 Change to the CD-ROM drive.
4 Issue the following command:
3.2.6 Verifying the Installation on Solaris Sparc Systems
Verify the 3PAR Host Explorer agent installation for the Red Hat Linux system:
1 Log on as the System Administrator.
2 Issue the following command:
# r pm- i vh Host Expl or er - <r el ease_number >. i 386. r pm
r pm- qa | gr ep Host Expl or er
# pkgadd - d Host Expl or er - spar c. pkg
# pkgi nf o - l Host Expl or er
3.5
Deinstallation
3PAR Host Explorer Users Guide
3.3 Deinstallation
This section describes how to deinstall a 3PAR Host Explorer agent on:
Microsoft Windows Server 2003 and 2008, 32 bit and 64 bit
Red Hat Linux systems running RHEL4 Update 6 or later and RHEL5
Sparc systems running Solaris 10
3.3.1 Deinstalling a 3PAR Host Explorer Agent on Microsoft Windows Server
To deinstall a 3PAR Host Explorer agent from a Microsoft Windows Server 2003 or 2008 system:
1 Log on as the System Administrator.
2 Select Start > Settings > Control Panel > Add/Remove Programs.
Result: The Add/Remove Programs window appears.
3 Select 3PAR Host Explorer for Windows.
4 Click Remove.
3.3.2 Deinstalling a 3PAR Host Explorer Agent on Red Hat Linux Systems
To deinstall a 3PAR Host Explorer agent from a Red Hat Linux system:
1 Log on as the root user.
2 Issue the following command:
3.3.3 Deinstalling a 3PAR Host Explorer Agent on Solaris Sparc Systems
To deinstall a 3PAR Host Explorer agent from a Solaris Sparc system:
1 Log on as the root user.
2 Issue the following command:
r pm- e Host Expl or er - <r el ease_number >. i 386. r pm
pkgr mHost Expl or er
3.6
Deinstallation
3PAR Host Explorer Users Guide
3PAR Host Explorer Users Guide
4.1 Using the Host Explorer
4
Using the Host Explorer
In this chapter
4.1 Overview 4.2
4.2 Verifying the 3PAR Host Explorer Package is Installed 4.2
4.3 Verifying the 3PAR Host Explorer Process is Running 4.2
4.4 Stopping the 3PAR Host Explorer Process 4.2
4.5 Starting the 3PAR Host Explorer Process 4.3
4.6 Supporting Multiple InServ Storage Servers on a Single Host 4.3
4.7 Supporting VMware Virtual Machines with iSCSI 4.3
4.8 The 3PAR Host Explorer Enclosure Device LUN 4.3
4.2
Overview
3PAR Host Explorer Users Guide
4.1 Overview
The chapter provides instructions for using the 3PAR Host Explorer.
4.2 Verifying the 3PAR Host Explorer Package is Installed
To verify that the 3PAR Host Explorer package has been installed correctly, see the appropriate
section below:
To find out if the product is installed on a Solaris system, see Verifying the Installation on
Solaris Sparc Systems on page 3.4.
To find out if the product is installed on a Linux system, see Verifying the Installation on
Red Hat Linux Systems on page 3.4.
To find out if the product is installed on a Windows system, see: Verifying the Installation
on Microsoft Windows Server on page 3.3.
4.3 Verifying the 3PAR Host Explorer Process is Running
To verify that the 3PAR Host Explorer process is running, issue the TpdHost Agent status
command.
Example output:
4.4 Stopping the 3PAR Host Explorer Process
By default, the Host Explorer process starts at every reboot of the host.
If you do not want the process running on the host, issue the TpdHost Agent st op
command.
Pr i nt i ng t he st at us of 3PAR Host Expl or er daemon:
3PAR Host Expl or er i s r unni ng. .
The cur r ent t i me i nt er val val ues ar e:
Val ue i s PushI nt er val =86400 default
Val ue i s Ref r eshI nt er val =60 default
4.3
Starting the 3PAR Host Explorer Process
3PAR Host Explorer Users Guide
4.5 Starting the 3PAR Host Explorer Process
To start the Host Explorer process, issue the TpdHost Agent st ar t command.
4.6 Supporting Multiple InServ Storage Servers on a Single Host
The 3PAR Host Explorer reports the information it collects to every InServ Storage Server
attached to the host.
If an InServ Storage Server is added or removed after the initial installation of the 3PAR Host
Explorer, a refresh is needed.
To refresh the Host Explorer process, issue the TpdHost Agent r ef r esh command.
4.7 Supporting VMware Virtual Machines with iSCSI
The 3PAR Host Explorer supports VMware Virtual Machines connected to InServ Storage
Servers with iSCSI connections. For information about supported Operating Systems on
VMware Virtual Machines, refer to the InForm OS Configuration Matrix available from 3PARs
Document Control System.
4.8 The 3PAR Host Explorer Enclosure Device LUN
When a host is connected to an InServ Storage Server, an enclosure device with LUN ID 254 is
automatically defined for the host. The 3PAR Host Explorer uses this enclosure device to
exchange information about the host with the InServ Storage Server. The LUN with ID 254 acts
as both a data LUN and an enclosure service LUN. You can use LUN ID 254 for any application
with limited impact on performance. The level of impact on performance depends on the
application. The LUN with ID 254 is presented to the host even when no virtual volumes are
exported to the host, or when the host is not configured on the InServ Storage Server.
4.4
The 3PAR Host Explorer Enclosure Device LUN
3PAR Host Explorer Users Guide
4.8.1 InServ Storage Server Upgrades and Enclosure Devices
If you upgraded to 3PAR InForm Operating System version 2.3.1 from a previous release, you
must consider the following notes about LUNs with ID 254.
If you had a LUN with ID 254 before you upgraded to 2.3.1, the host persona for the host is
set to the Generic-Legacy persona number 6 during the upgrade process. The port persona
number must be reset to Generic persona number 1 before the Host Explorer can
communicate with the InServ Storage Server.
1) Use the InForm Command Line Interface (CLI) set host per sona 1 <host name>
command to set the host persona number to 1.
2) Use the cont r ol por t of f l i ne command to take the InServ Storage Server port
the host is connected to offline.
3) Use the cont r ol por t r st command to reset the InServ Storage Server port
connected to the host.
Alternatively, if you reboot the host after resetting the persona number as described in
step 1, the Host Explorer automatically discovers the enclosure device on LUN ID 254 and
sends the information to the InServ Storage Server. For more information about CLI
commands, see the 3PAR InForm OS CLI Administrators Manual.
If you add a host after you upgrade to 2.3.1, the host persona number for the host must be
set to 1. For more information about creating and modifying hosts, see the 3PAR InForm OS
CLI Administrators Manual.
You can also use the InForm Management Console to configure and administer hosts
connected to the InServ Storage Servers. For more information, see the 3PAR InForm OS
Management Console Online Help.
3PAR Host Explorer Users Guide
5.1 TpdHostAgent Command
5
TpdHostAgent Command
In this chapter
5.1 Overview 5.1
5.2 TpdHostAgent Command 5.2
5.1 Overview
The TpdHostAgent is a simple command line interface for maintaining and managing the
various options to be used in conjuction with the Host Explorer daemon.
This command must be run as superuser/administrator from the host where it is installed.
5.2
TpdHostAgent Command
3PAR Host Explorer Users Guide
5.2 TpdHostAgent Command
COMMAND
TpdHost Agent
DESCRIPTION
Command line utility for management of a 3PAR Host Explorer.
SYNTAX
TpdHost Agent [ opt i ons]
OPTIONS
- st ar t
Starts the Host Explorer process.
- st op
Stops the Host Explorer process.
- r ef r esh
Stops, then restarts the Host Explorer process.
- st at us
Lists the status of a Host Explorer process, i.e. whether the daemon/service is
running.
- l i st
Lists the contents of all host configuration information (Host Explorer tokens) that
has been gathered by the Host Explorer.
- push
Immediately sends the latest Host Explorer token information to the InServ Storage
Server.
- set <Ref r eshI nt er val >| <PushI nt er val >
Changes the default time intervals (Ref r eshI nt er val = 60 seconds, PushI nt er val =
86,400 seconds) used by the daemon to send token information to the InServ
Storage Server.
5.3
TpdHostAgent Command
3PAR Host Explorer Users Guide
RefreshInterval - The interval that the Host Explorer process collects the data and
compares it to the last known state for any changes. If there are changes, the Host
Explorer pushes the new set of data to the InServ Storage Server.
PushInterval - The interval that the Host Explorer process pushes data to InServ
Storage Server.
- set t r ace <1- 5>
This option is only available on the Windows operating system.
1 - Displays error messages.
2 - Display warning messages and all messages below this level.
3 - Displays information messages and all messages below this level.
4 - Displays verbose messages and all messages below this level.
5 - Displays debug messages and all messages below this level.
SPECIFIERS
None.
RESTRICTIONS
None.
EXAMPLES
Starting the Host Explorer deamon.
# TpdHost Agent st ar t
St ar t i ng t he 3PAR Host Expl or er daemon . .
St ar t i ng 3PAR Host Expl or er : [ OK ]
5.4
TpdHostAgent Command
3PAR Host Explorer Users Guide
Checking the status of the Host Explorer deamon.
# TpdHost Agent st at us
Pr i nt i ng t he st at us of 3PAR Host Expl or er daemon:
3PAR Host Expl or er i s r unni ng . . .
The cur r ent t i me i nt er val val ues ar e:
Val ue i s PushI nt er val =86400
Val ue i s Ref r eshI nt er val =60
Stopping the Host Explorer deamon.
# TpdHost Agent st op
St oppi ng t he 3PAR Host Expl or er daemon. .
St oppi ng 3PAR Host Expl or er : [ OK ]
Sending the latest Host Explorer token information to the InServ Storage Server
# TpdHost Agent push
Sendi ng t he t oken i nf or mat i on i mmedi at el y
Listing the contents of all host configuration information (Host Explorer tokens) gathered by
the Host Explorer.
# TpdHost Agent l i st
Li st i ng t he Token i nf or mat i on.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TPDAGENTVER=1. 1. 0- 14
HNAME=192. 168. 45. 14
HOSTI D=a8c00e2d
OS=Li nux
OSVER=2. 6
OSPATCH=9- 22. ELsmp
ARCH=i 686
I P=192. 168. 45. 14
MPSW=devi ce- mapper
MPSWVER=1. 01. 04- 1. 0. RHEL4
HBA0WWN=210000e08b0786bd . . .
5.5
TpdHostAgent Command
3PAR Host Explorer Users Guide
. . . HBA0VEN=QLogi c
HBA0MODEL=QLA2342
HBA0DRVRVER=8. 01. 00b5- r h2
HBA0FI RMWARE=3. 03. 15 I PX
HBA1WWN=210100e08b2786bd
HBA1VEN=QLogi c
HBA1MODEL=QLA2342
HBA1DRVRVER=8. 01. 00b5- r h2
HBA1FI RMWARE=3. 03. 15 I PX
DEVI CE0WWN=50002ac0000900c4
DEVI CE0NAME=350002ac0000900c4
DEVI CE0I OPOLI CY=r ound- r obi n
DEVI CE0FPMPOLI CY=t ur
DEVI CE0TOTPATHCNT=2
DEVI CE0GDPATHCNT=2
DEVI CE0PATH0HWWN=210000e08b0786bd
DEVI CE0PATH0TWWN0=21510002ac0000c4
DEVI CE0PATH0TWWN0STATE=OK
DEVI CE0PATH0TWWN1=20510002ac0000c4
DEVI CE0PATH0TWWN1STATE=OK
DEVI CE1I OPOLI CY=r ound- r obi n
DEVI CE1FPMPOLI CY=t ur
DEVI CE1TOTPATHCNT=2
DEVI CE1GDPATHCNT=2
DEVI CE1PATH0HWWN=210000e08b0786bd
DEVI CE1PATH0TWWN0=21510002ac0000c4
DEVI CE1PATH0TWWN0STATE=OK
DEVI CE1PATH0TWWN1=20510002ac0000c4
DEVI CE1PATH0TWWN1STATE=OK
5.6
TpdHostAgent Command
3PAR Host Explorer Users Guide
3PAR Host Explorer Users Guide
RH.1 Revision History

Revision History
Release level Revision summary
320-200132 Rev A
October 2009
First release of this manual.
RH.2

3PAR Host Explorer Users Guide

You might also like