You are on page 1of 18

DOCUMENT

FOR UPDATION
OF
PRL IN OTA/MANUALLY
CREATED MIN/MDN

1
Scenario 1:-
PRL Update in OTA Created MIN/MDN (RUIM/Instruments):

Requirements:

1. MIN/MDN should be created in HLR through OTAF.


2. Instrument in which RUIM card is loaded should support OTAPA
services.

PRL Update Procedure:

Step 1:

Go to ZXC10 System Analysis and select ZXC10-MSS OTAF Agent system

Fig 1

In ZXC10-MSS OTAF Agent system, click on “Send Singly”

Fig 2

2
Step 2:

Input the MIN/MDN no. in which PRL need to Update, and check in “PRL
parameters” check box

Fig 3

Step 3:

Click on arrow button to drag the “Cellular CDMA- Custom Channels”


toward the Acquisition table to add the frequency channels.

Fig 4

3
Double click on “Cellular CDMA- Custom Channel “

Fig 5

To add the frequency channels which need to update, enter the channel no.
and click on “Add”. When all required channels added, click on “OK” to
submit.

Fig 6

Step 4:

To add SID/NID which is to be configured, click on “Add”

4
Fig 7

Enter the SID, NID and select the “Roaming indicator” ON/OFF as per
requirement.
Check the “Cellular CDMA-Custom Channels box” and “Preffered/Negative
System box”.

Fig 8

After Configure all above parameters click on “OK” to submit .

Fig 9

5
Select Pref_Only to “1” and Roaming indicator ON/OFF as per requirement

Fig 10

Step 5:

Click on “OK” to start the OTAPA session to update the PRL in instrument

Fig 11

After Successful update of PRL parameters in RUIM, System provide a


acknowledge message “Start OTASP Data Message successful” on Screen

6
Fig 12

Scenario 2:-
PRL Update in Manually created MIN/MDN(RUIM/Instruments):

Requirement:

Requirement 1:
Instruments/RUIM card in which we want to update PRL, should have
facility to configure A-Key.

A-Key configuration for different available instrument is as following:

ZTE EVDO Card:


Open the ZTE EVDO card programming menu by using ZTEPST
software. GO to CDMA, Select “input” and input the A-Key in Decimal
format in Akey field and click on write to save:
Example: like if we want to configure A-Key – 2652026011265202( that
is in HEX format) in HLR Agent system when creating the MIN/MDN,
then we need to configure A-Key- 2761272133159375362 ( this is
decimal equivalent of “2652026011265202”) in EVDO Cards Akey field.

7
Fig 13

Huawei NIC/PCMCIA Card:

Use the FWT Configuration tool to open the instrument programming mode.
Go to ServMaintenance and select “HEX” mode, input the A-Key in HEX
format (same as configured in HLR Agent system), and click on Write to
save.

8
Fig 14

RUIM Card:

Confirm A-key configured in RUIM card, and Configure same A-Key in


HLR agent when creating the MIN/MDN in HLR.
Note: Take care about A-Key format in RUIM card (whether it is in HEX
or Decimal), If it is in Decimal, need to convert it into HEX and
configure it in HLR agent.

Requirement 2:

Select Authentication Required and SSD Shared when add the


authentication in HLR to create the MIN/MDN, and input the A_Key in
HEX format same as configured in instrument.

9
Fig 15

Requirement 3:

MIN/MDN which is created in HLR, should get success in SSD update.

SSD Update Procedure is following:

To Update the SSD go to Authentication and select Authentication


Indicator(U) in HLR Agent system.

Fig 16

10
Enter the MIN/MDN and click on Query

Fig 17

Select SSD Update, Unique Challenge and click on OK to start the SSD
Update session

Fig 18

11
After Successful SSD update, Success message will show in the
Authentication Indicator result field

Fig 19

Requirement 4:

When updating PRL in data cards (EVDO or NIC card), it


should be confirm that card is connected to network.

PRL Update Procedure:

Step 1:

Go to ZXC10 System Analysis and select ZXC10-MSS OTAF Agent system

Fig 20

In ZXC10-MSS OTAF Agent system, click on “Send Singly”


12
Fig 21

Step 2:

Input the MIN/MDN no. in which PRL need to Update, and check in “PRL
parameters” check box

Fig 22

13
Step 3:

Click on arrow button to drag the “Cellular CDMA- Custom Channels”


toward the Acquisition table to add the frequency channels.

Fig 23

Double click on “Cellular CDMA- Custom Channel “

Fig 24

To add the frequency channels which need to update, enter the channel no.
and click on “Add”. When all required channels added, click on “OK” to
submit.

14
Fig 25

Step 4:

To add SID/NID which need to configure, click on “Add”

Fig 26

Enter the SID, NID and select the “Roaming indicator” ON/OFF as per
requirement.
Check the “Cellular CDMA-Custom Channels box” and “Preferred/Negative
System box”.

15
Fig 27

After Configure all above parameters click on “OK” to submit .

Fig 28

Select Pref_Only to “1” and Roaming indicator ON/OFF as per requirement

16
Fig 29

Step 5:

Click on “OK” to start the OTAPA session to update the PRL in instrument

Fig 30

After Successful update of PRL parameters in RUIM, System provide a


acknowledge message “Start OTASP Data Message successful” on Screen.
17
Note: If system is giving failure message, once perform the SSD update as
per given SSD update procedure (as shown in fig 17, 18, 19) and after that
try for the PRL update.

Fig 31

After Successful SSD update message, check the PRL in instrument /RUIM
card through appropriate programming tool.

Prepared By

Deepak Kumar Pandey


MSS Engineer (O & M),
Gujarat Circle,
Central Region-2
Mob-9904454884