You are on page 1of 5

COMANDO ETABLE

ETABLE, Lab, Item, Comp


Riempie una tabella di valori per ulteriori elaborazioni.
Lab
Qualsiasi etichetta definita dallutente per limpiego nei comandi sucessivi e voci di uscita
(massimo otto caratteri e non etichette item generali predefinite).
Item
Etichetta che identifica la voce.
Comp
Componente delletichetta (se richiesta).
General Item and Component Labels
ETABLE,Lab,I tem,Comp
Item Comp Description
Valid Item Labels for Degree of Freedom Results
U X,Y,Z X, Y, or Z structural displacement.
ROT X,Y,Z X, Y, or Z structural rotation.
TEMP

Temperature.
PRES

Pressure.
VOLT

Electric potential.
MAG

Magnetic scalar potential.
V X,Y,Z X, Y, or Z fluid velocity.
A X,Y,Z X, Y, or Z magnetic vector potential.
CURR

Current.
EMF

Electromotive force drop.
ENKE

Turbulent kinetic energy.
ENDS

Turbulent energy dissipation.
SP0n

Mass fraction of species n, where n=1 to 6. If a species is given a user-
defined name [MSSPEC], use that name instead of SP0n.
Valid Item Labels for FLOTRAN Nodal Results
TTOT

Total temperature.
HFLU

Heat flux.
HFLM

Heat transfer (film) coefficient.
COND

Fluid laminar conductivity.
PCOE

Pressure coefficient.
PTOT

Total (stagnation) pressure.
MACH

Mach number.
STRM

Stream function. (2-D applications only.)
DENS

Fluid density.
VISC

Fluid laminar viscosity.
EVIS

Fluid effective viscosity.
ECON

Fluid effective conductivity.
YPLU

Y+, a turbulent law of the wall parameter.
TAUW

Shear stress at the wall.
LMDn

Laminar mass diffusion coefficient for species n, where n = 1 to 6.
EMDn

Effective mass diffusion coefficient for species n, where n = 1 to 6.
Valid Item and Component Labels for Element Results
S X,Y,Z,XY,YZ,XZ Component stress.

1,2,3 Principal stress.

INT,EQV Stress intensity or Equivalent stress.
EPTO X,Y,Z,XY,YZ,XZ Component total strain (EPEL + EPPL + EPCR).

1,2,3 Principal total strain.

INT,EQV Total strain intensity or total equivalent strain.
EPEL
X,Y,Z,
XY,YZ,XZ
Component elastic strain.

1,2,3 Principal elastic strain.

INT,EQV Elastic strain intensity or elastic equivalent strain.
EPPL X,Y,Z,XY,YZ,XZ Component plastic strain.

1,2,3 Principal plastic strain.

INT,EQV Plastic strain intensity or plastic equivalent strain.
EPCR
X,Y,Z,
XY,YZ,XZ
Component creep strain.

1,2,3 Principal creep strain.

INT,EQV Creep strain intensity or creep equivalent strain.
EPTH
X,Y,Z,
XY,YZ,XZ
Component thermal strain.

1,2,3 Principal thermal strain.

INT,EQV Thermal strain intensity or thermal equivalent strain.
EPSW

Swelling strain.
NL SEPL Equivalent stress (from stress-strain curve).

SRAT Stress state ratio.

HPRES Hydrostatic pressure.

EPEQ Accumulated equivalent plastic strain.

PSV Plastic state variable.

PLWK Plastic work/volume.
TG X,Y,Z,SUM Component thermal gradient or vector sum.
TF X,Y,Z,SUM Component thermal flux or vector sum.
PG X,Y,Z,SUM Component pressure gradient or vector sum.
EF X,Y,Z,SUM Component electric field or vector sum.
D X,Y,Z,SUM Component electric flux density or vector sum.
H X,Y,Z,SUM Component magnetic field intensity or vector sum.
B X,Y,Z,SUM Component magnetic flux density or vector sum.
FMAG X,Y,Z,SUM Component magnetic forces or vector sum.
SERR

Structural error energy.
SDSG

Absolute value of maximum variation of any nodal stress component.
TERR

Thermal error energy.
TDSG

Absolute value of the maximum variation of any nodal thermal gradient
component.
F X,Y,Z Component structural force. Sum of element nodal values.
M X,Y,Z Component structural moment. Sum of element nodal values.
HEAT

Heat flow. Sum of element nodal values.
FLOW

Fluid flow. Sum of element nodal values.
AMPS

Current flow. Sum of element nodal values.
FLUX

Magnetic flux. Sum of element nodal values.
VF X,Y,Z Component fluid force.
CSG X,Y,Z Component magnetic current segment.
SENE

"Stiffness" energy or thermal heat dissipation (applies to all elements
where meaningful). Same as TENE.
AENE

Artificial energy of the element. This includes the sum of hourglass
control energy and energy generated by in-plane drilling stiffness from
shell elements (applies to all elements where meaningful). The energy
is used for comparisons to SENE energy to predict the solution error
due to artificial stiffness.
TENE

Thermal heat dissipation or "stiffness" energy (applies to all elements
where meaningful). Same as SENE.
KENE

Kinetic energy (applies to all elements where meaningful).
JHEAT

Element Joule heat generation (coupled-field calculation).
JS X,Y,Z,SUM
Source current density (coupled-field calculation) and vector sum in the
global Cartesian coordinate system.
JT X,Y,Z,SUM Total current density and vector sum
MRE

Magnetics Reynolds number
VOLU

Element volume. ANSYS uses a unit thickness of one for area
elements.
CENT X,Y,Z
Undeformed X, Y, or Z location (based on shape function) of the
element centroid in the active coordinate system.
BFE TEMP
Body temperatures (calculated from applied temperatures) as used in
solution (area and volume elements only).
SMISC snum
Element summable miscellaneous data value at sequence
number snum(shown in the Output Data section of each applicable
element description in Chapter 4 of the ANSYS Elements Reference).
NMISC snum
Element non-summable miscellaneous data value at sequence
numbersnum (shown in the Output Data section of each applicable
element description found in Chapter 4 of the ANSYS Elements
Reference).
SURF snum
Element surface data value at sequence number snum (shown in Section
2.2.2.5 of the ANSYS Elements Reference).
CONT1 STAT
Contact status. 3-closed and sticking, 2-closed and sliding, 1-open but
near contact, 0-open and not near contact.

PENE Contact penetration (zero or negative)

PRES Contact pressure

SFRIC Contact friction stress

STOT Contact total stress (pressure plus friction)

SLIDE Contact sliding distance

GAP Contact gap distance
TOPO

Densities used for topological optimization. This applies to the
following types of
elements: PLANE2, PLANE82, SOLID92, SHELL93,SOLID95.

















COMANDO ESOL
ESOL, NVAR, ELEM, NODE, Item, Comp, Name