Electric Equipment General Catalog

Load Break Switches


(
LBS
)
Load Break Switches
(
LBS
)
vJL Jype
D-6
Auxiliories &
Devices
D-8
|nslollolion
Jype
D-10
Circuil
Diogroh
D-12
Culside
Drowing
D-13
Puse $eleclion
$londord
D-15
Cfficiol
Aulhenlicolion Jesl
[xehplion Cerlificole
D-17
Contents
Different grade of LBS
|OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss] |OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss]
|OnIy VITZkOTFCHs L8$ is !he onIy F3 cIoss]
E3 class capacity
with 100A fuse
combination
E3 class capacity
with built in
lightning arrester
Performance comparison by class
according to IEC60265
Other companies
VITZROTECH LBS is the first and best E3 class LBS in the country.
D-2 VITZRO TECH LBS
Other
Other
E3 class capacity with
100A fuse combination
& built in LA
bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI! bpQroded New ModeI on o Differen!io!ed LeveI!
bpQroded New ModeI on o Differen!io!ed LeveI!
According to the development of 100A fuse-combined LBS that requires a performance three times higher
than the existing 63A device, the protection range for a transformer was extended up to 100A.
Maximum fuse capacity of fuse combination LBS
Transfer current breaking capacity of load
switch according to the fuse capacity
Other
VITZRO
Other
VITZRO
D-3 Electric Equipment General Catalog

Developed the countrys first LA-embedded LBS

Developed type tests for all types, in E3 class

Passed 100A fuse combination type test

Developed the countrys first LA-embedded LBS

Developed type tests for all types, in E3 class

Passed 100A fuse combination type test


All you need is the LA-Embedded LBS!
| koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ] | koreos firs! LAFmbedded L8$! ]
| koreos firs! LAFmbedded L8$! ]
LA Embedded LBS

The size of the switch panel can become smaller as


additional space for LAs is not necessary, so that cost
reduction can be realized.
Insulator Material
D-4 VITZRO TECH LBS
Excellent electrical and mechanical strength and
arc-resistance of the support insulator formed
with polysil (our patented product) and built-in LA,
and epoxy puffer insulator minimize the influence
to other devices
in the panel.
| LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ] | LA inside L8$ ]
| LA inside L8$ ]
This product is the same size as existing LBS because LA is Embedded in the support insulator.
^enbeooeo }3
,4|V 40|^
LA embedded inside
the support insulator
18kV 2.5kA
Dual contact structure by main blade and
arcing blade prevents the damage on the
main blade
Pressurized air discharge maximizes the
instantaneous arc extinguishing capacity.
Main Circuit Section
Arcing blade
Main blade
Arc chute
Fixed contact
Puffer insulator (Epoxy)
D-5 Electric Equipment General Catalog
D-6 VITZRO TECH LBS
New E3 class High-Performance Model
Type LBS basic LBS+LA embedded LBS+fuse LBS+LA+fuse
Name
VTL VTL VTL VTL VTLF VTLF VTLF VTLF
24/630A1 24/630M1 24/630A1-LA1 24/630M1-LA1 24/630A1 24/630A1 24/630A1-LA1 24/630A1-LA1
Operation type Auto Manual Auto Manual Auto Manual Auto Manual
Fuse-mounted No Yes
LA-mounted No Yes No Yes
Rated voltage 24kV
Rated current 630A Switch 630A/ Fuse 100A
Switch rating (IEC standard) E3, M1 Class
Pole 3 poles
Rated frequency 60Hz
Rated short-time withstand current 20kA/1sec -
Rated making current 52kAp 104kAp
Power frequency To ground 50kV/min
withstand voltage Same phase 60kVmin
Lightning impulse To ground 125kVp
withstand voltage Same phase 145kVp
Load current
630A 100 times
31.5A 20 times
Loop current 630A 20 times
Cable 31.5A 10 times
Charging current 9.45A 10 times
Line charging current 1.5A 10 times
No-load switching 1,000 times
Rated breaking current - 40kArms
Rated transfer current - 1250Arms
Rated fuse current (Fuse-mounted type) N/A
Up to 100A
1/5/10/16/20/25/31.5/40/50/63/80/100
Rated control voltage 110Vdc - 110Vdc - 110Vd - 110Vdc -
Rated control current 5A - 5A - 5A - 5A -
Manual operation cable length Standard: 2.0m (Option: 1.5/2.6m)
Weight 68kg 64kg 74kg 70kg 92kg 88kg 98kg 94kg
)
* LA For LA-embedded type
LA specification (LA-embedded type) 1) Rated voltage : 18kV 2) Nominal discharge current: 2.5kA 3) Rated frequency: 60Hz
4) Power frequency withstand voltage: 50kV/1min 5) Lightning impulse withstand voltage: 125kVp
Applied standard IEC60265-1, IEC62271-105, IEC60282-1
Curreni
swiiobinq
iines
Basic type
Embedded LA
Fuse-combrination type
Embedded LA
100A fuse applied
kML Type
AuxiIiories &
Devices
Ins!oIIo!ion
Type
Circui!
DioQrom
Ou!side
DrowinQ
Fuse seIec!ion
$!ondord
VTL Type
D-7 Electric Equipment General Catalog
Load Break Switches
D
L
o
a
d

B
r
e
a
k
S
w
i
t
c
h
e
s
KML Type-12kV Manual Operation-only
KML Type - 12kV Manual Operation-only
OrderinQ odes
Fuse Yes
Fuse No
F
N
Fuse-mounted
VTL
KML
Type
F
Auto
Manual
A
M
Operation type
A LA A
DC110V
AC110V
AC220V
A
B
C
Operating voltage
A
1.5M
1.8M
2.0M
A
B
C
Manual operation cable length
Specify the
rated current
when necessary
Fuse capacity
100 VTL
12 kV
12KML-M
3 Pole
630A
50/60Hz
32kV
85kV
20kA
52kA
630A
630A
31.5A
60ms
Manual
-
-
62.5kg
Standard: 2.0m (Option: 1.5/2.6m)
Rated voltage
Type
Pole
Rated current
Rated frequency
Power frequency withstand voltage
Impulse withstand voltage
Rated short-time current (1s)
Rated short circuit making current
Load current
Loop current
Charging current
Opening time
Operation type
Operating voltage
Operating current
Weight (Without fuse)
Manual operation cable lengt
Curreni swiiobinq
oapaoii,
LA No
LA Yes
-
-
LA-mounted
* KML type is dedicated to 12kV manual operation.
Air Circuit Breakers
D-8 VITZRO TECH LBS
2.3
24
442
4.1
3.1
78
65
VTHF24001 1
VTHF24005 5
VTHF24010 10
VTHF24016 16
VTHF24020 20
VTHF24025 25
VTHF24032 31.5
VTHF24040 40
VTHF24050 50
VTHF24063 63
VTHF24080 80
VTHF25100 100
Model name
Rated current Rated maximum Rated minimum
Weight
In breaking current breaking current
[A] [kA] [A]
[kg]
24/25.8kV Fuse Link
40 5In
56
Dimension
e
[mm]
d
[mm]
Rated voltage
[kV]
25.8
Example of fuse-mounted LBS installation
Striker
This one line diagram is an example installation where the fuse
combination LBS applicable. The rated current of the power fuse
is chosen considering the capacity of power-receiving transformer
and the protection coordination with OCR.
VITZRO LBS is equipped with a fuse combined trip device that
automatically trips when one fuse is melted due to short circuit or
overcurrent, so that it operates quickly and accurately in case of
fault in any phase.
VTL TyIe kML Type
Ins!oIIo!ion
Type
Circui!
DioQrom
Ou!side
DrowinQ
Fuse seIec!ion
$!ondord
AuxiIiories& Devices
Incoming
LBS with Fuse combination
WHM
COS or PF
COS, PF or CB
Load Load Load
D-9 Electric Equipment General Catalog
Load Break Switches
D
L
o
a
d

B
r
e
a
k
S
w
i
t
c
h
e
s
Auxiliaries& Devices
F|eIrio||yDriven OperoIinQ uniI
This is used for remote On/Off control. The standard
rated voltage is DC 110V, but AC 110V/AC 220V are
also available by individual order.
Monuo| kemoIe OperoIinQ uniI
This is used for manual operation at the panel door,
and comprises a cable and a manual handle.
Fuse Combined Trip Devie
This device provides trip operation to prevent open
phase operation in case one fuse out of three fuses is
melted due to a fault, which is clear and quick using
mechanical links.
Fuse Combined ndioIor ConIoI
1a contact i s provi ded to enabl e the remote
monitoring of fuse melting. (F1-F2)
Auxi|iory ke|oy
This relay operates according to the main blade
operation, and is used in indicating the switch status and
controlling the switch.
CounIer
This is a switching counter that indicates the number of
switching times of LBS
$hunI Trip Devie
This device is equipped with a shunt coil to facilitate
quick trip operation by the signal from the relay in case
of fault.
P N C T F1
A1 A3 B1 B3 F2
A2 A4 B2 B4
Auxiliary relay
Counter
Fuse melting indicator contact
Shunt trip device
Fuse melting trip device
Manual
handle
Electrically-
driven
operating unit
Remote operation cable
D-10 VITZRO TECH LBS
Monuo| remoIe operoIinQ uniI
L8$ Moin 8ody
Fixed frame
Above R150
Manual handle
Cable fixture
(Switch cabinet door)
Cable
1. The standard length is 2.0m, and 1.5/2.6m can also be manufactured by order.
2. The cable requires sufficient radius curvature above R150 for good operation.
3. The manual On/Off operation by cable is conducted by single direction turn (right turn).
4. Fix the cable with cable ties to the inside wall of switch cabinet considering the insulation distance.
5. Use the separately provided exclusive handle for manual operation.
----- corresponds to the horizontal
installation.
* Check if the surface on which the device is installed is flat, to prevent the distortion of LBS
Horizontal Installation
Vertical installation
Basic type Fuse-mounted
Circuit diagram for
installation
VTL TyIe kML Type
AuxiIiories &
Devices
Circui!
DioQrom
Ou!side
DrowinQ
Fuse $eIec!ion
$!ondord
Ins!oIIo!ion Type
D-11 Electric Equipment General Catalog
Load Break Switches
D
L
o
a
d

B
r
e
a
k
S
w
i
t
c
h
e
s
Circuit
Nomes by seIion
QBase Frame
QSupport Insulator
QLoad Terminal
QArcing Blade
QMain Blade
QLine Terminal
QArc Nozzle
QFixed Main Contact
Q Fixed Support Insulator
QOperating Rod
QOperating Mechanism
QManual Operation Cable
Geared Motor
QManual Handle
QSupport Insulator
QLoad Terminal
QCurrent limiting Power Fuse
Fuse Trip Device
Q Q
Q
Q
Q Q
Q
Q
Q
Q

Q
Q
Q
Q
Q

Q
Q
Circuit
D-12 VITZRO TECH LBS
Automatic (Electrically-driven)
ConIro| CiruiI / AuIomoIi
P : AC 110V / AC 220V ()
N : AC 110V / AC 220V ()
C : CLOSE
T : TRIP
SC : Trip Coil
(DC 110V / DC 220V)
M: Motor for closing
DC 110V / DC 220V)
89X : Auxiliary relay for closing
P : DC 110V ()
N :: DC 110V ()
C : CLOSE
T : TRIP
SC : Trip Coil
M: Motor for closing
89X : Auxiliary relay for closing
AC 110V / AC 220V
DC 110V
VTL TyIe kML Type
AuxiIiories &
Devices
Ins!oIIo!ion
Type
Ou!side
DrowinQ
Fuse $eIec!ion
$!ondord
Circui! DioQrom
Manual
C
o
n
t
r
o
l

v
o
l
t
a
g
e
(
D
C
1
1
0
V
)
Manual Combination
Manual
C
o
n
t
r
o
l

v
o
l
t
a
g
e
(
D
C
1
1
0
V
)
Manual Combination
D-13 Electric Equipment General Catalog
Load Break Switches
D
L
o
a
d

B
r
e
a
k
S
w
i
t
c
h
e
s
Outside Drawing
VTL (F3 |oss) New Mode|
Basic Type/LA-Embedded Type (Auto/Manual)
Fuse-Mounted Type/LA-Embedded Type (Auto/Manual)
Outside Drawing
D-14 VITZRO TECH LBS
T2kMLM
12kV, Manual-Exclusive
Installation dimension
Basic type and LA-embedded type (12KML-M) Fuse-mounted type and LA-embedded type
VTL TyIe kML Type
AuxiIiories &
Devices
Ins!oIIo!ion
Type
Circui!
DioQrom
Fuse seIec!ion
$!ondord
Ou!side DrowinQ
D-15 Electric Equipment General Catalog
Load Break Switches
D
L
o
a
d

B
r
e
a
k
S
w
i
t
c
h
e
s
Fuse Selection Standard
Fuse $e|eIion $Iondord by usoQe
Power fuse for transformer circuit protection
<Detailed selection condition>
1. The inrush current of transformer was estimated by assuming 10 times the transformer full load current for 0.1s.
2. The rated fuse current was estimated so that 1.5 to 2 times the transformer rated current could be continuously conducted.
3. The transformer fuse was selected on the assumption that it could break in less than 2 seconds at 25 times the transformer
rated current in case of secondary short circuit.
Fuse Selection Standard
Rated voltage
Rated capacity of transformer [kVA] 3+ Fuse link
[kV]
7~15 VTHF24001
36 ~ 76 VTHF24005
75 ~ 158 VTHF24010
141 ~ 276 VTHF24016
176 ~ 344 VTHF24020
220 ~ 431 VTHF24025
264 ~ 540 VTHF24032
466 ~ 990 VTHF24040
600 ~ 1238 VTHF24050
743 ~ 1585 VTHF24063
990 ~ 1981 VTHF24080
1585 ~ 2641 VTHF25100
2251 ~ 3301 VTHF24125
3522 ~ 4226 VTHF24160
24
PF
TR