AccessWave Series

Upgrade Guide
From V7.1.x or 7.2.1 to 7.3.1
Release 01

417006-2305-0H3-A04



AccessWave Series Upgrade Guide from V7.1.x or 7.2.1 to V7.31
Catalog No: X38138
Release 01, April 2010









Copyright by ECI Telecom, 2010. All rights reserved worldwide.
This is a legal agreement between you, the end user, and ECI Telecom Ltd. (ECI Telecom). BY OPENING THE
DOCUMENTATION AND/OR DISK PACKAGE, YOU ARE AGREEING TO BE BOUND BY THE TERMS OF THIS
AGREEMENT. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE
UNOPENED DOCUMENTATION AND/OR DISK PACKAGE AND THE ACCOMPANYING ITEMS (INCLUDING
WRITTEN MATERIALS AND BINDERS OR OTHER CONTAINERS), TO THE PLACE FROM WHICH YOU
OBTAINED THEM.
The information contained in the documentation and/or disk is proprietary and is subject to all relevant copyright,
patent, and other laws protecting intellectual property, as well as any specific agreement protecting ECI Telecom's
rights in the aforesaid information. Neither this document nor the information contained in the documentation and/or
disk may be published, reproduced, or disclosed to third parties, in whole or in part, without the express prior
written permission of ECI Telecom. In addition, any use of this document, the documentation and/or the disk, or the
information contained therein for any purposes other than those for which it was disclosed, is strictly forbidden.
ECI Telecom reserves the right, without prior notice or liability, to make changes in equipment design or
specifications. Information supplied by ECI Telecom is believed to be accurate and reliable. However, no
responsibility whatsoever is assumed by ECI Telecom for the use thereof, nor for the rights of third parties, which
may be affected in any way by the use and/or dissemination thereof.
Any representation(s) in the documentation and/or disk concerning performance of ECI Telecom product(s) are for
informational purposes only and are not warranties of product performance or otherwise, either express or implied.
ECI Telecom's standard limited warranty, stated in its sales contract or order confirmation form, is the only warranty
offered by ECI Telecom.
The documentation and/or disk is provided AS IS and may contain flaws, omissions, or typesetting errors. No
warranty is granted nor liability assumed in relation thereto, unless specifically undertaken in ECI Telecom's sales
contract or order confirmation. Information contained in the documentation and in the disk is periodically updated,
and changes will be incorporated in subsequent editions. If you have encountered an error, please notify ECI
Telecom. All specifications are subject to change without prior notice.
The documentation and/or disk and all information contained therein is owned by ECI Telecom and is protected by
all relevant copyright, patent, and other applicable laws and international treaty provisions. Therefore, you must
treat the information contained in the documentation and disk as any other copyrighted material (for example, a
book or musical recording).
Other Restrictions. You may not rent, lease, sell, or otherwise dispose of the documentation and disk, as
applicable. YOU MAY NOT USE, COPY, MODIFY, OR TRANSFER THE DOCUMENTATION AND/OR DISK OR
ANY COPY IN WHOLE OR PART, EXCEPT AS EXPRESSLY PROVIDED IN THIS LICENSE. ALL RIGHTS NOT
EXPRESSLY GRANTED ARE RESERVED BY ECI TELECOM.
All trademarks mentioned herein are the property of their respective holders.
ECI Telecom shall not be liable to you or to any other party for any loss or damage whatsoever or howsoever
caused, arising directly or indirectly in connection with this documentation and/or disk, the information contained
therein, its use, or otherwise. Notwithstanding the generality of the aforementioned, you expressly waive any claim
and/or demand regarding liability for indirect, special, incidental, or consequential loss or damage which may arise
in respect of the documentation and/or disk and/or the information contained therein, howsoever caused, even if
advised of the possibility of such damages.
The end user hereby undertakes and acknowledges that they read the "Before You Start/Safety Guidelines"
instructions and that such instructions were understood by them.
It is hereby clarified that ECI Telecom shall not be liable to you or to any other party for any loss or damage
whatsoever or howsoever caused, arising directly or indirectly in connection with you fulfilling and/or failed to fulfill
in whole or in part the "Before You Start/Safety Guidelines" instructions.
Document History
The following table records information regarding released editions of this document and
briefly describes the changes made to them.

Rev. No. Release Date Responsible Approved by Description of Changes
A00 Yosi Avraham First version




Document Approvals
Title Name Signature Date Remarks
ON Technical
Presale
Ori Shinberg

Approved 7.4.10
ON Manager Oron Kfir Approved 7.4.10
ON PLM Yosi Avraham Approved 7.4.10










426006-2423-023-A00 ECI Telecom Ltd. Proprietary i

Contents
About This Manual ................................................................... vii
Overview ............................................................................................................ vii
Intended Audience ............................................................................................. vii
Document Organization ...................................................................................... vii
Document Conventions ..................................................................................... viii
Obtaining Technical Documentation ................................................................... ix
Technical Assistance ............................................................................................ x
Features of the AccessWave Series ................................................................... xi
AccessWave Series Overview ................................................ 1-1
AccessWave Series Common Equipment ............................................................. 1-1
Shelf and Module Compatibility ............................................................................ 1-2
AccessWave Series Management Interfaces ........................................................ 1-5
Upgrading to Release 7.3.1 ..................................................... 2-1
Upgrade Task Flow ............................................................................................. 2-1
Before you Upgrade to Release 7.3.1 ................................................................... 2-2
Performing Database Backup .............................................................................. 2-3
Setting up the AccessWave Management System .......................................... 2-6
Loading, Invoking, and Committing the System Software Upgrade ............... 2-12
Equipment Installing and Provisioning ........................................................... 2-21
Auto-upgrade Support on Modules ................................................................ 2-21
Returning to an Earlier Version of the System Software ..... 3-1
Cancelling a System Software Upgrade Process using the AccessWave
Management System ....................................................................................... 3-1
Cancelling a System Software Upgrade Process using TL1 ............................ 3-3
Downgrading the System Software using the AccessWave Management
System ............................................................................................................. 3-5
Downgrading the System Software using TL1 ....................................................... 3-7
Useful Procedures ................................................................... 4-1
Determining System Software Release Numbers ............................................ 4-1
Database Restoring using the AccessWave Management System ................. 4-2
Database Restoring using TL1 ......................................................................... 4-4
Establishing an AccessWave Management System Session using
Ethernet ............................................................................................................ 4-8
Establishing a TL1 Session using RS-232 ..................................................... 4-12
Contents AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

ii ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Troubleshooting ...................................................................... 5-1
Checking Failures ............................................................................................. 5-1
Loading Failures ............................................................................................... 5-4
Invoking Failure ................................................................................................ 5-7
Committing Failure ........................................................................................... 5-9
Cancelling Failure ............................................................................................. 5-9
Provisioning Failure ........................................................................................ 5-10
Module Upgrade Failure ................................................................................. 5-11
Database Recovery Failure ............................................................................ 5-11




426006-2423-023-A00 ECI Telecom Ltd. Proprietary iii

List of Figures
Figure 4-1: Establishing an AccessWave Management System session using
Ethernet .......................................................................................................................... 4-9
Figure 4-2: Establishing an AccessWave Management System session using
Ethernet .......................................................................................................................... 4-9
Figure 4-3: Establishing a TL1 session using the RS-232 Craft serial port ................. 4-12
Figure 4-4: Establishing a TL1 session using the RS-232 Craft serial port ................. 4-12
Figure 4-5: DB-9 Pin Connector and 8 Pin RJ-45 Connector Numbering
Schemes ...................................................................................................................... 4-14


List of Figures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

iv ECI Telecom Ltd. Proprietary 426006-2423-023-A00





426006-2423-023-A00 ECI Telecom Ltd. Proprietary v

List of Tables
Table 1-1: Common equipment supported in Release 7.3.1 ......................................... 1-1
Table 1-2: Common equipment...................................................................................... 1-2
Table 1-3: Optical Amplifier modules ............................................................................. 1-2
Table 1-4: Dispersion Compensation modules .............................................................. 1-3
Table 1-5: Optical Multiplexing modules ........................................................................ 1-3
Table 1-6: Transponder modules ................................................................................... 1-4
Table 1-7: Muxponder modules ..................................................................................... 1-5
Table 1-8: Optical Packet Switch modules .................................................................... 1-5
Table 4-1: IP Addresses ................................................................................................. 4-8
Table 4-2: Pin Assignments for RS-232 DB-9 Pin Connectors and RS-232 RJ-45
Connectors ................................................................................................................... 4-15



List of Tables AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

vi ECI Telecom Ltd. Proprietary 426006-2423-023-A00





426006-2423-023-A00 ECI Telecom Ltd. Proprietary vii

Overview
This preface explains who should read the Upgrade Guide , how the guide is
organized, related documentation, documentation conventions, how to obtain
documentation, and how to obtain technical support.
Intended Audience
This guide is primarily intended for technicians and network operation center
(NOC) staff.
Document Organization
This manual contains the following information:
Chapter Description
Chapter 1, AccessWave Series
Overview
This chapter provides information about the common
equipment, modules, and management interfaces supported
by AccessWave Series Release 7.3.1.
Chapter 2, Upgrading to
Release 7.3.1
This chapter provides information about upgrading the
system software from Release 7.2.1 to Release 7.3.1.
Chapter 3, Returning to an
Earlier Version of the System
Software
This chapter provides information about returning the
AccessWave Series to an earlier version of the system
software.
Chapter 4, Useful Procedures This chapter provides information about other procedures
you can perform when upgrading to Release 7.3.1.
Chapter 5, Troubleshooting This chapter provides information about troubleshooting
the issues that might arise when upgrading from Release
7.2.1 to Release 7.3.1.
About This Manual
About This Manual AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

viii ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Document Conventions
When applicable, this manual uses the following conventions.

Convention Indicates Example
Bold Names of windows, dialog
boxes, menus, buttons and
most other GUI elements
In the Alarms menu...
Menu > Option Selection from a menu, or
leading to another
command
Select Update > View
Objects
Courier New Font
Code syntax and code
examples, UNIX
commands, user-typed
information
>>Starting default
primary application,
please wait...
Italics New terms and emphasized
text
Examples in text
Borders around text Notes, cautions, warnings,
laser warnings, EDS
warnings, tips, and
important notes
See examples below


NOTE: Text set off in this manner presents clarifying
information, specific instructions, commentary, sidelights, or
interesting points of information.


CAUTION: Text set off in this manner indicates that failure to
follow directions could result in damage to equipment or loss
of information.


WARNING: Text set off in this manner indicates that failure to
follow directions could result in bodily harm or loss of life.



LASER WARNING: Text set off in this manner indicates
how to avoid personal injury. All personnel involved in
equipment installation, operation, and maintenance must be
aware that laser radiation is invisible. Therefore, although
protective devices generally prevent direct exposure to the
beam, personnel must strictly observe the applicable safety
precautions and, in particular, must avoid staring into optical
connectors, either directly or using optical instruments.


AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
About This Manual

426006-2423-023-A00 ECI Telecom Ltd. Proprietary ix


ESD: Text set off in this manner indicates information on
how to avoid discharge of static electricity and subsequent
damage to the unit.


TIP: Text set off in this manner includes helpful information
and handy hints that can make your task easier..


IMPORTANT: Text set off in this manner presents essential
information you must pay attention to.

Obtaining Technical
Documentation
To obtain technical documentation related to ECI Telecom products, please
contact:
ECI Telecom Ltd.
Documentation Department
30 Hasivim St.
Petach Tikva 49130
Israel
Fax: +972-3-9268060
Email: techdoc.feedback@ecitele.com

About This Manual AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

x ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Technical Assistance
The configuration, installation, and operation of ECI Telecom products in a
network are highly specialized processes. Due to the different nature of each
installation, some planning aspects may not be covered in this manual.
If you have questions or concerns about your network design or if you require
installation personnel to perform the actual installation process, ECI Telecom
maintains a staff of design engineers and highly trained field service personnel.
The services of this group are available to customers at any time.
If you are interested in obtaining design assistance or a network installation
plan from ECI Telecom's Customer Support team, contact your ECI Telecom
sales representative. With any support related issues, technical or logistic,
please contact the ECI Telecom Customer Support center at your location. If
you are not familiar with that location, please contact our central customer
support center action line at:
Telephone +972-3-9266000
Telefax +972-3-9266370
Email on.support@ecitele.com


AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
About This Manual

426006-2423-023-A00 ECI Telecom Ltd. Proprietary xi

Features of the AccessWave
Series
ECI Telecom AccessWave Series latest release resets the standard for metro
service delivery with powerful new modules and tools designed to expand fiber
capacity and reduce the complexity of optical-Ethernet engineering. Release
7.3 allows service providers to quickly deliver multi-service optical and packet
network services while it delivers better performance for high-capacity
enterprise network environments. Enhancements to AccessWave Series and
Management System suite enable network planners and administrators to
design and add new services and capacity efficiently and easily. Highlights of
this release include:
Support for G.8032 ring protection switching on Optical Packet Switch
AccessWave Management System network and nodal management for all
AW-60 modules and features
Tunable 10G XFPsthe next generation in Pluggable Optics for flexible
wavelength planning
Release 7.3 introduces the following packet-optical enhancements:
Tunable XFPs supporting:
50GHz channel spacing
Addresses AccessWave 40-ch wavelength plan at 100GHz
Optical specification alignment with fixed 10G DWDM XFPs
Copper SFP support on the GE Muxponder, 10-port Muxponder, 8-port
Muxponder
The Optical Packet Switch now supports:
Ethernet ring protection switching (G.8032)
Improved fault management with IEEE 802.1ag and ITU-T Y.1731
Ethernet service OAM, supporting CCMs, L2 ping and L2 trace-route
Management VLAN
Ethernet service statistics defined by UNI, C-VLAN and CoS
New Ethernet PMs: Bandwidth utilization, Rx octets, Rx violate octets,
Rx conform and exceed octets
10-port Multiprotocol Muxponder now supports:
OC-3/12 STM-1/4 Clients
Basic SSM
Enables provisioning of VCAT and CCAT on a per port basis
About This Manual AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

xii ECI Telecom Ltd. Proprietary 426006-2423-023-A00

8-port Multiprotocol Muxponder now supports:
Basic SSM
HD SDI
Enables provisioning of VCAT and CCAT on a per port basis
Platform Improvements:
BER PM
24 hour PM bins
Security enhancements (TL1/SSH, secure FTP, 500 user-ids)
AccessWave Management System fully supports:
New 7.3 Optical Packet Switch services
New Muxponder module service provisioning
Tunable XFPs
New alarms and PMs
Release 7.3.1 of AccessWave Management System provides initial support
for AccessWave Series NEs running release 7.3 software with the
following limitations:
New alarms introduced at release 7.3 are not supported
New PM points introduced at release 7.3 are not supported
The following table lists the shelves and other common equipment introduced
as part of the AccessWave Series. For detailed information about the
AccessWave Series, see the Product Guide and the Common Equipment
Installation Guide.
AccessWave Series Common Equipment

Equipment Module Name
AccessWave 60 platform AW-60 Shelf
AccessWave 60 platform with rear access -48V AW-60 SHELF REAR -48V
AccessWave 60 platform Cooling Unit (CU) AW-60 COOLING UNIT
AccessWave 60 platform Main Shelf Interface (MSI) AW-60 MSI
AccessWave 60 platform Expansion Shelf Interface (ESI) AW-60 ESI
AccessWave 60 platform System Control Processor (SCP) AW-60 SCP
AccessWave 60 platform AC Power Assembly Kit AW-60 AC PWR ASSY KIT
AccessWave 60 platform AC Power Module AW-60 AC POWER UNIT
AccessWave 30 platform AW-30 SHELF
AccessWave 30 platform Cooling Unit (CU) AW-30 COOLING UNIT
AccessWave 30 platform Main Shelf Interface (MSI) AW-30 MSI
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
About This Manual

426006-2423-023-A00 ECI Telecom Ltd. Proprietary xiii

Equipment Module Name
AccessWave 30 platform System Control Processor (SCP) AW-30 SCP
AccessWave 30 platform AC Power Assembly Kit AW-30 AC PWR ASSY KIT
AccessWave 30 platform AC Power Module AW-30 AC POWER UNIT
AccessWave 20 platform AW-20 PASSIVE SHELF
The following table lists the AccessWave Series modules introduced as part of
the AccessWave Series. For detailed information about these modules, see the
Solutions Guide for the module portfolio.
AccessWave Series modules


IMPORTANT NOTE: All SDH CCAT cards have been
consolidated with VCAT cards. As from Version 7.3 SDH
cards consist of CCAT and VACT.

AccessWave Series Modules Module Name
Dual 4G Multiprotocol Transponder 4-PORT 4G WT 3R
Dual 10G Multiprotocol Transponder DUAL 10G WM
Dual 10G Multiprotocol Transponder Lite DUAL 10G WM 3R(LITE)
10G Multiprotocol Transponder SINGLE 10G WM 3R+PM
8-Port Multiprotocol Muxponder SONET 8P ANY MUX SONET
8-Port Multiprotocol Muxponder SDH 8P ANY MUX SDH
10-Port Multiprotocol Muxponder SONET 10P 10G MUX SONET
10-Port Multiprotocol Muxponder SDH 10P 10G MUX SDH
Optical Packet Switch 2 Lines 12 clients OPS 2-12
Optical Packet Switch 2 Lines 24 clients OPS 2-24
Optical Packet Switch 4 Lines 24 clients OPS 4-24
The management software suite was renamed for the AccessWave Series. The
following table identifies the new name of each application in the suite. For
detailed information about each application, see the Online Help for the
application.
Management Software Suite Evolution

AccessWave Software Name
AccessWave Network Manager AccessWave EMS
AccessWave Node Controller AW_LCT
AccessWave Network Designer AccessWave Builder
About This Manual AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

xiv ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Equipment Compliance
The following table provides agency-compliance information for AccessWave
Series equipment.
Agency Compliance

Agency Compliance information
FDA This equipment is classified by the FDA under IEC 60825, parts 1
and 2, as a Class 1 laser product with a Class 1 hazard rating.
FCC This equipment complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause
undesired operation.
Industry
Canada
This Class A digital apparatus complies with Canadian ICES-003.
Organization of the AccessWave Series
Documentation
The following guides are contained in the AccessWave Series documentation
suite.
Common Equipment Installation Guide
Quick Install Notes
Upgrade Guide
Operations Solution Guide
Transponder Solutions Guide
Muxponder Solutions Guide
Optical Packet Switch Solution Guide
Amplifier and DCM Solutions Guide
Multiplexing Solutions Guide
Alarm and Troubleshooting Guide
SNMP Reference Guide
TL1 Reference Guide
Optical Packet Switch Command Line Interface Reference Guide
Release Notes


426006-2423-023-A00 ECI Telecom Ltd. Proprietary 1-1

This section provides information about the common equipment, modules, and
management interfaces supported by AccessWave Series Release 7.3.1.
AccessWave Series Common
Equipment
The following table lists the AccessWave Series shelves and other common
equipment supported in Release 7.3.1. For detailed information about the
AccessWave Series, see the Product Guide and the Common Equipment
Installation Guide.
Table 1-1: Common equipment supported in Release 7.3.1
Equipment Module Name
AW-60 AW-60 Shelf
AW-60 with rear access -48V AW-60 Shelf rear -48v
AW-60 Cooling Unit (CU) AW-60 Cooling Unit
AW-60 Main Shelf Interface (MSI) AW-60 MSI
AW-60 Expansion Shelf Interface (ESI) AW-60 ESI
AW-60 System Control Processor (SCP) AW-60 SCP
AW-60 AC Power Assembly Kit AW-60 AC PWR Assy kit
AW-60 AC Power Module AW-60 AC Power Unit
AW-30 AW-30 Shelf
AW-30 Cooling Unit (CU) AW-30 Cooling Unit
AW-30 Main Shelf Interface (MSI) AW-30 MSI
AW-30 System Control Processor (SCP) AW-30 SCP
AW-30 AC Power Assembly Kit AW-30 AC PWR Assy kit
AW-30 AC Power Module AW-30 AC Power Unit
AW-20 AW-20 Passive Shelf
1
AccessWave Series Overview
AccessWave Series Overview AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

1-2 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Shelf and Module Compatibility
The following tables identify the AccessWave Series modules that are
supported on AW-60 shelves that have been upgraded to the AccessWave
Series platform and on AccessWave Series shelves. For information about
upgrading AW-60 shelves to the AccessWave Series platform, see the Upgrade
Guide Release 6.2 to Release 7.1.0.


NOTE: The AW-30 shelf cannot be upgraded to Release 7.3.1
and, therefore, cannot support AccessWave Series modules
Table 1-2: Common equipment
AccessWave Series modules Module Name AW-30 AW-60
AW-60 Cooling Unit (10,000 rpm) AW-60 Cooling Unit No No
AW-60 Main Shelf Interface AW-60 MSI No No
AW-60 Expansion Shelf Interface AW-60 ESI No No
AW-60 Multiport System Control
Processor
AW-60 SCP No Yes
AW-30 Cooling Unit AW-30 Cooling Unit Yes No
AW-30 Main Shelf Interface AW-30 MSI Yes No
AW-30 System Control Processor AW-30 SCP Yes No
Table 1-3: Optical Amplifier modules
AccessWave Series modules Module Name AW-30 AW-60
DWDM C-Band Pre-Amplifier DWDM Pre_AMP UC Yes Yes
DWDM C-Band Booster Amplifier DWDM Boost_AMP UC Yes Yes
Optical Line Amplifier OLA SC Yes Yes
Optical Line Amplifier with mid-
stage access
OLA w/ Mid_stage SC Yes Yes
Single Channel and Sub-band Booster
Amplifier
Sub Band Boost_AMP
UC
Yes Yes
Single Channel and Sub-band Pre-
Amplifier
Sub Band Pre_AMP UC Yes Yes
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
AccessWave Series Overview

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 1-3

Table 1-4: Dispersion Compensation modules
AccessWave Series modules Module Name AW-30 AW-60
SMF Dispersion Compensation Module 20km SMF DCF 20KM UC Yes Yes
SMF Dispersion Compensation Module 40km SMF DCF 40KM SC Yes Yes
SMF Dispersion Compensation Module 60km SMF DCF 60KM SC Yes Yes
SMF Dispersion Compensation Module 80km SMF DCF 80KM SC Yes Yes
SMF 100 GHz C-Band DCM 40km SMF C-Band DCM
40km
Yes Yes
SMF 100 GHz C-Band DCM 60km SMF C-Band DCM
60km
Yes Yes
SMF 100 GHz C-Band DCM 80km SMF C-Band DCM
80km
Yes Yes
Table 1-5: Optical Multiplexing modules
AccessWave Series modules Module Name AW-30 AW-60
4-Channel CWDM Mux/Demux, Channel 1 - 4 4Ch CWDM M/D 1-4 Yes Yes
4-Channel CWDM Mux/Demux, Channel 5 - 8 4Ch CWDM M/D 5-8 Yes Yes
4-Channel CWDM Mux/Demux,
Channel 9 - 12
4Ch CWDM M/
D 9-12
Yes Yes
4-Channel CWDM Mux/Demux, Channel
13- 16
4Ch CWDM M/
D 13-16
Yes Yes
1-Channel CWDM OADM 1Ch CWDM OADM
Ch#1
Yes Yes
Double 1-Channel OADM Du 1Ch CWDM
OADM Ch#1
Yes Yes
2-Channel CWDM OADM 2Ch CWDM OADM
Ch#1&2
Yes Yes
32-Channel DWDM Mux/Demux Module 1 8Ch DWDM M/D 1-8 Yes Yes
32-Channel DWDM Mux/Demux Module 2 8Ch DWDM M/
D 9-16
Yes Yes
32-Channel DWDM Mux/Demux Module 3 8Ch DWDM M/
D 17-24
Yes Yes
32-Channel DWDM Mux/Demux Module 4 8Ch DWDM M/
D 25-32
Yes Yes
32-Channel DWDM Bidirectional Mux/
Demux1
8Ch Bi-dir DWDM
MB2/DB4
8Ch Bi-dir DWDM
MB4/DB2
No No
32-Channel DWDM Bidirectional Mux/
Demux2
8Ch Bi-dir DWDM
MB1/DB3
8Ch Bi-dir DWDM
MB3/DB1
No No
1-Channel DWDM OADM 1Ch DWDM OADM
Ch#1
Yes Yes
2-Channel DWDM OADM 2Ch DWDM OADM
Ch#1&2
Yes Yes
AccessWave Series Overview AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

1-4 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

AccessWave Series modules Module Name AW-30 AW-60
4-Channel DWDM OADM 4Ch DWDM OADM
Ch#1-4
Yes Yes
4-Channel DWDM OADM, ECI Channels 53,
55, 57, 59
4Ch DWDM OADM
Extra
Yes Yes
CWDM + DWDM Splitter Combiner CWDM+DWDM S/C Yes Yes
1310nm and C-Band Coupler/Splitter 1310nm & C-Band
S/C
Yes Yes
DWDM Bidirectional Coupler/Splitter Du Bi-dir S/C Yes Yes
1
Supported on AW-20 only
2
Supported on AW-20 only.
Table 1-6: Transponder modules
AccessWave Series modules Module Name AW-30 AW-60
1G Wavelength Translator 4-PORT 1G WT 2R Yes Yes
1G Wavelength Regenerator 4-PORT 1G WR 3R Yes Yes
2.5G Wavelength Regenerator 4-PORT 2.5G WR 3R Yes Yes
2.5G Wavelength Manager 4-PORT 2.5G WM
3R+PM
Yes Yes
Dual 4G Multiprotocol Transponder with PMs 4-PORT 4G WT 3R Yes Yes
Dual 10G Multiprotocol Transponder DUAL 10G WM
3R+PM
Yes Yes
Dual 10G Multiprotocol Transponder Lite DUAL 10G WM
3R(LITE)
Yes Yes
10G Multiprotocol Transponder SINGLE 10G WM
3R+PM
Yes Yes
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
AccessWave Series Overview

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 1-5

Table 1-7: Muxponder modules
AccessWave Series modules Module Name AW-30 AW-60
2-Port GbE Muxponder (OC-48 with
protection)
2.5G MUXPONDER
OC-48
Yes Yes
2-Port GbE Muxponder (STM-16 with
protection)
2.5G MUXPONDER
STM-16
Yes Yes
8-Port Multiprotocol Muxponder - SONET 8P ANY MUX
SONET
Yes Yes
8-Port Multiprotocol Muxponder - SDH 8P ANY MUX SDH Yes Yes
10-port 10G Multiprotocol Muxponder -
SONET
10P 10G MUX
SONET
Yes Yes
10-port 10G Multiprotocol Muxponder - SDH 10P 10G MUX SDH Yes Yes


IMPORTANT NOTE: All SDH CCAT cards have been
consolidated with VCAT cards. As from Version 7.3 SDH
cards consist of CCAT and VACT.
Table 1-8: Optical Packet Switch modules
AccessWave Series modules Module Name AW-30 AW-60
Optical Packet Switch Integrated OPS 2-12 Yes Yes
Optical Packet Switch Integrated OPS 2-24 No Yes
Optical Packet Switch Integrated OPS 4-24 No Yes
AccessWave Series Management
Interfaces
The AccessWave Series supports standard communication interfaces over
serial and IP connections, including Telcordia Transaction Language One
(TL1), SNMP, and GCC0. In addition, the AccessWave Series provides the
AccessWave Management System, a Java-based craft management interface, for
management of individual NEs.
The main tasks in this Upgrade Guide are described using both AccessWave
Management System-based procedures and TL1-based procedures.
For information about the management interfaces that the AccessWave Series
supports, refer to the following documentation:
AccessWave Management System Online Help
TL1 Reference Guide
SNMP Reference Guide
Management Communications Channel Solutions Guide

AccessWave Series Overview AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

1-6 ECI Telecom Ltd. Proprietary 426006-2423-023-A00



426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-1

This section provides information about upgrading the system software from
Release 7.1.x or 7.2.1 to Release 7.3.1.
Upgrade Task Flow
The following list identifies the order of tasks in the process for upgrading a
system from Release 7.1.x or 7.2.1 to Release 7.3.1.
1. Perform a database backup.
For information, see Performing Database Backup.
2. If you use the AccessWave Management System to manage AccessWave
Series nodes, set up the AccessWave Management System by uninstalling
Release 7.2.1 of the AccessWave Management System, and then installing
Release 7.3.1.
For information, see Setting up the AccessWave Management System.
3. Load, invoke, and commit the system software upgrade. For information,
see Loading, Invoking, and Committing the System Software Upgrade.
4. Install and provision new shelves and modules, and if necessary, replace
common equipment such as the Cooling Unit. For information, see the
Common Equipment Installation Guide, the Operations Solution Guide,
and the Solutions Guide for the module portfolio.
2
Upgrading to Release 7.3.1
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-2 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Before you Upgrade to Release
7.3.1
The following is a check list to be reviewed before upgrading the system
software from Release 7.1.x or 7.2.1 to Release 7.3.1.
The document Release Notes for Release 7.3.1 has been reviewed for
information about upgrading the system software.
The "Troubleshooting" chapter of the Solutions Guide for each module type
installed or to be installed on the system has been reviewed for information
relating to a system software upgrade.
The management network is operating at an acceptable performance level.
There are no CONTCOM alarms on the system. See the Alarm and
Troubleshooting Guide for information about clearing a CONTCOM alarm.
The location to which the database will be backed up has enough space to
store the data.


NOTE: A fully configured AW-60 main shelf and its log files
can create a backup file of several megabytes in size. For
more information, see Performing Database Backup.
If you are replacing the SCP, ensure that both software banks on their
placement SCP are loaded with the same software image of the release to
which you are upgrading, and that the release numbers for the Active and
Inactive software banks match.
If you use the AccessWave Management System to manage AccessWave
Series nodes in the network, ensure the following:
The AccessWave Management System Release 7.2.1 is available to
perform a database backup of the Release 7.2.1 configuration database.
The AccessWave Management System Release 7.3.1 is available for
installation. For information, see Setting up the AccessWave
Management System.
The computer on which the AccessWave Management System will be
installed meets the minimum requirements for the software. For
information, see Installing AccessWave Management System Release
7.3.1 on Microsoft Windows or Installing AccessWave Management
System Release 7.3.1 on Solaris.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-3


NOTE: AFFECTED SERVICES DURING UPGRADE
When a system-level upgrade has been completed, you must
perform a cold restart of all 8-port & 10-port Multiprotocol
Muxponders installed on the system. A cold restart is
required to enable provisioning of Release 7.3.1 features and
activation of software updates on these Muxponder modules.

Performing Database Backup
The AW-60 SCP maintains all provisionable data in non-volatile storage so
that configuration settings are retained during a system shutdown and restart.
This configuration database is version controlled to facilitate the detection of an
incompatible software load or database.
Before you upgrade the system software to Release 7.3.1, you can back up the
database locally, to an FTP server, or to the AccessWave Series SCP.


IMPORTANT: ECI Telecom recommends that the database be
backed up to the SCP and either locally or to an FTP server.
Backing up to the SCP enables you to cancel the upgrade if
necessary, and then revert to the configuration database stored
on the SCP.
If you choose to back up to an FTP server, you can either specify a particular
FTP server or use the FTP utility embedded in the AccessWave Management
System.
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-4 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Database Backup using the AccessWave
Management System
Prerequisites
If backing up to an FTP server, the server must be set up for remote
backups.
The backup location has enough space for the data.


NOTE: Data for either a main shelf only or for a main shelf
and an expansion shelf requires several megabytes of free
space.
To back up the database using the AccessWave
Management System:
1. Select Administration from the View menu.
2. In the System pane, click Database Backup to display the database backup
settings.
3. In the Backup Settings panel, do one of the following:
a. Choose Local PC to back up the database to the local computer, enter a
name for the backup file in the File field, and then click Save As.
b. Choose Remote PC to back up the database to an FTP server, specify
the connection settings to the server, and then enter the path to the file,
including the file name, in the File field.


NOTE: Some UNIX systems may require you to enter the
entire directory path and the database file name in the File
field.


NOTE: If you use the embedded FTP server, the default
directory will be the same as the AccessWave Management
System installation directory.
c. Choose SCP to backup the database to the AccessWave Series SCP,
and then enter a name for the backup file in the File field.


NOTE: If you select SCP, any backup file already stored on
the SCP will be overwritten.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-5

4. If alarms are present on the system, select the Ignore Alarms check box.


IMPORTANT: The database backup will not proceed if
alarms are present on the system and the Ignore Alarms check
box has not been selected.
5. Click Backup.
Messages indicating the progress of the database backup appear in the
Status window.
If the backup is successful, the message Backup Process Completed
Successfully appears. If the backup fails, an error message appears.
Database Backup using TL1
Prerequisites
If backing up to an FTP server, the server must be set up for remote
backups.
The backup location has enough space for the data.


NOTE: Data for either a main shelf only or for a main shelf
and an expansion shelf requires several megabytes of free
space.

To back up the database using TL1:
1. Enter the following at the TL1 command line interface:
INVK-DB-BKUP:[TID]:::<CTAG>::TYPE=<TYPE>,[IPADDR=<IPADDR>],
[PATH=<PATH>],[USERID=<USERID>],[PWD=<PWD>],[CHKALM=<CHKALM>]
;
where
<TYPE> is FTP or SCP
<IPADDR> is the address of the FTP server where the backup file will be
stored
<PATH> is the path to the database backup file, including the file name


NOTE: The value <PATH> can contain a maximum of 54
alphanumeric characters when TYPE=FTP and 48
alphanumeric characters when TYPE=SCP.

Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-6 ECI Telecom Ltd. Proprietary 426006-2423-023-A00


NOTE: Some UNIX systems may require you to enter the
entire directory path and the database file name.
<USERID> is the user ID for the FTP server
<PWD> is the password assigned to the user ID <CHKALM> is Y or N


IMPORTANT: If CHKALM=Y and alarms are present on the
system, the database backup will not proceed
If the backup is successful, the system returns the following message:
AccessWave Series 08-12-31 16:22:02
M 100 COMPLD
;
AccessWave Series>
AccessWave Series Series 08-12-31 16:22:05
A 103 REPT EVT EQPT
"SCP-1-5:DBBKUPPASS,,05-12-31,16-22-04,,,,,:\"Database Backup
Completed Successfully.\",,,:,"
;
If the backup fails, an error message appears.
Setting up the AccessWave
Management System
If you use the AccessWave Management System to manage AccessWave
Series nodes on the network, ECI Telecom recommends that Release 7.2.1 of
AccessWave Management System be uninstalled before AccessWave
Management System Release 7.3.1 is installed.


NOTE: If your network includes AccessWave Series nodes
(i.e., nodes running Release 6.2 or earlier of the system
software), the AccessWave Node Controller must be used for
local GUI operation of these nodes. The AccessWave
Management System must be used for local GUI operation of
AccessWave Series nodes (i.e., nodes running Release 7.3 of
the system software). The AccessWave Node Controller and
AccessWave Management System can operate in the same
network environment.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-7

Uninstalling AccessWave Management
System Release 7.2.1 on Microsoft Windows
Prerequisites
Log out of and exit AccessWave Management System Release 7.2.1.
To uninstall AccessWave Management System on Windows:
1. Navigate to the directory where AccessWave Management System is
installed, and open the folder Uninstaller Data.
2. Double-click the file Uninstall.exe. the AccessWave Management System
uninstaller application starts, and displays the message Uninstall
Complete when the process is completed.
3. Remove the
AccessWave Management System
directory from your
computer.
You have successfully completed this procedure.
Uninstalling the AccessWave Management
System Release 7.2.1 on Solaris
Prerequisites
Log out of and exit AccessWave Management System Release 7.2.1.
To uninstall AccessWave Management System on Solaris:
1. Open a terminal window and navigate to the directory where AccessWave
Management System is installed. and then type the following at the prompt:
2. At the prompt, type the following to open the folder Uninstaller Data:
cd UninstallerData
3. At the prompt, type the following to start the uninstaller application:
/ Uninstall
The AccessWave Management System uninstaller application displays the
message Uninstall Complete when the uninstall process is completed.
4. At the prompt, type the following to remove the AccessWave Management
System directory:
rm -r <directoryname>
You have successfully completed this procedure.
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-8 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Installing AccessWave Management System
Release 7.3.1 on Microsoft Windows
What you need
AccessWave Management System CD-ROM
Prerequisites
Ensure that the computer meets the following minimum requirements:
Operating system: Windows 2003 Server, or Windows XP
Windows-supported browsers: Internet Explorer version 6.0 or later, or any
Mozilla-based browser version 2 or later
Recommended minimum screen resolution: 1024 x 768 pixels
Minimum color depth: 256 colors
1 GHz AMD/Intel
300 MB minimum of available disk space
2 GB minimum of RAM
To install AccessWave Management System on Windows:
1. Place the CD-ROM in your CD-ROM drive.
2. Open My Computer or use Windows Explorer to navigate to your
CD-ROM drive.
3. Open the install.htm file located in the folder.
The AccessWave Management System software download web page opens.
4. Click Install AccessWave Management System 7.3.1.
A security warning may appear.
5. Click Open.
6. Follow the instructions that appear on the AccessWave Management
System installer screen.
The AccessWave Management System installer guides you through the
following steps:
Introduction
Choose Install Folder
Installation Warnings

AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-9


NOTE: If the AccessWave Management System is already
installed on the computer, you may be asked to uninstall the
software or stop the installation procedure.
Choose Shortcut Folder
Pre-Installation Summary
Installing
Install complete
You have successfully completed this procedure.
Installing AccessWave Management System
Release 7.3.1 on Solaris
What you need
AccessWave Management System CD-ROM
Prerequisites
Ensure that the UNIX workstation meets the following minimum requirements:
Operating System: Solaris 10
Solaris Supported Browsers: Mozilla, Netscape, FireFox, Konqueror, Opera,
or Epiphany
Recommended minimum screen resolution: 1024 x 768 pixels
Minimum color depth: 256 colors
UltraSPARC III CPU
300 MB minimum of available disk space
2 GB minimum of RAM
To install AccessWave Management System on Solaris:
1. Place the CD-ROM in the CD-ROM drive, and then navigate to the
directory where the CD-ROM drive is mounted.
2. Open the install.htm file located in the folder.
A security warning may appear. Click Grant to close this dialog window.
3. Click Install Now.
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-10 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

4. Follow the instructions that appear on the AccessWave Management
System installer screen. The AccessWave Management System installer
guides you through the following steps:
Introduction
Choose Installation Folder
Installation Warnings


NOTE: If the AccessWave Management System is already
installed on the workstation, you may be asked to uninstall the
software or stop the installation procedure.
Pre-Installation Summary
Installing Progress
Install Complete
5. Set the PATH variable to the location where the web browser application
resides.


NOTE: first browser found in the path is the default browser.
You have successfully completed this procedure.
Troubleshooting Installation Problems
An installation log file is available in the installation directory for both
Windows and UNIX installations. The log file is titled:
AccessWave Management System_InstallLog.log
The log file provides information on the software components that were
installed successfully or failed to install.
Firewall Precaution
If you have the Windows Firewall enabled, a firewall exception must be
configured to allow the AccessWave Management System FTP server to
function. The firewall exception should be configured with the java executable
found in the AccessWave Management System Installation directory
("<installation directory>\jre\bin\javaw.exe).
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-11

Logging on to the AccessWave Series using
the AccessWave Management System
To log on to the AccessWave Series system using the
AccessWave Management System:


NOTE: The AccessWave Management System connects to the
AccessWave Series system through either a craft or
management LAN port. For more information, see
Establishing an AccessWave Management System Session
using Ethernet.
1. Start the AccessWave Management System.
2. In the Login dialog, enter the IP address that you want to connect to in the
NE field.
The default IP address of the Management LAN on the AccessWave
Management System is 10.0.0.1.
The default IP address of the Craft LAN port is 192.168.17.1.
3. In the User ID field, enter admin, which is the default user ID.
4. In the Password field, enter admin, which is the default password.
5.
Click OK.

The AccessWave Management System starts and establishes a session with
the AccessWave Series system.
You have successfully completed this procedure.
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-12 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Loading, Invoking, and
Committing the System Software
Upgrade
Release 7.3.1 of the system software can be loaded, invoked, and committed
using either Release 7.3.1 of the AccessWave Management System or TL1.
What you need
AccessWave Series CD.


NOTE: The AccessWave Series CD contains an encrypted
manifest file, a binary image file, and a readme file. The
manifest file contains a listing of all the software components
contained in the binary image. The manifest file and the
binary image file are required for upgrading the system
software.
Prerequisites
See Upgrade Task Flow and Before you Upgrade to Release 7.3.1.


IMPORTANT: Review the "Troubleshooting" chapter of the
Solutions Guide for each module type installed on the system
for information about additional procedures that might be
required during or after the system software upgrade.
You must be logged on to the system using Release 7.3.1 of the
AccessWave Management System.


NOTE: Release 7.3.1 of the AccessWave Management System
is backward compatible and can be used to manage Release
7.2.1 versions of the system software before the system
software is upgraded.
If you are using an external FTP server to access the AccessWave Series
CD, the FTP root directory must be configured to serve files from the CD, or
the CD files must be copied to the FTP root directory.
The FTP server and the AccessWave Series system must have IP
connectivity.
There are no CONTCOM alarms on the system.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-13

Recommendations
The state of the AccessWave Series system is In Service.
Remove or install modules during the upgrade process only if you are
instructed to do so.
Loading, Invoking, and Committing the
Upgrade
To load, invoke, and commit the system software upgrade
to Release 7.3.1 using the AccessWave Management System:
1. Insert the AccessWave Series CD into the CD-ROM drive.


NOTE: If you are using an FTP server other than the
embedded FTP server (i.e., a remote PC), install the CD in the
external FTP server.
2. Select Administration from the View menu.
3. In the System pane, click Software Upgrade to display the upgrade
settings.
4. In the Load Settings panel, do one of the following:
Choose Local PC (the default), and then click Browse to navigate to and
select the binary image file on the CD-ROM.
Choose Remote PC, specify the connection settings to the FTP server,
and then enter the path to the binary image file in the Directory field.


NOTE: Some UNIX systems may require you to enter the
entire directory path and file name in the Directory field.
5. Click Check to verify that the correct software upgrade file is available.
6. Click Load.
Release 7.3.1 of the system software takes several minutes to load.
7.
In the Upgrade Settings panel, verify that Release 7.3.1 is specified in the
Inactive
Release Number field and Release 7.2.1 is specified in the Active
Release Number field.
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-14 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

8. If alarms (other than CONTCOM) are present on the system, select the
Ignore Alarms check box in the Upgrade Settings panel.


IMPORTANT: The system software upgrade will not proceed
if alarms are present on the system and the Ignore Alarms
check box has not been selected.
9. Click Invoke.
The SYSUPGRDPROG (System Software Upgrade in Progress) alarm
is raised, and its severity is Minor.
The modules in the system are loaded with Release 7.3.1 of the system
software. The alarm severity changes from Minor to Major and the
system then restarts, starting with the SCP and followed by the
modules, and then the AccessWave Management System session ends.


IMPORTANT: The amount of time that the invoke operation
takes to complete depends on the configuration of the node.
For example, for a full four-shelf system, the invoke operation
may take up to one hour to complete.


NOTE: During re initialization, the red Fail LED on each
module in the node may light temporarily while the green
Active LED is lit.
10. When the red Fail LEDs turn off, start the AccessWave Management
System, and log on to the system.


NOTE: It can take several minutes to connect to the system.
11. In the Alarms pane, check the severity of the SYSUPGRDPROG alarm.
If the severity of the SYSUPGRDPROG alarm is Major, the system
upgrade is still in progress. Wait until the severity of the
SYSUPGRDPROG alarm changes to Minor, which indicates that the
system upgrade is complete, and then proceed to the next step.


NOTE: You can refresh the AccessWave Management System
GUI while the system upgrade is in progress.
If the severity of the SYSUPGRDPROG alarm is Minor, the system
upgrade is complete. Proceed to the next step.

AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-15


NOTE: At this point, you may cancel the software system
upgrade if necessary and revert to Release 7.2.1 of the system
software. For information, see Cancelling a System Software
Upgrade Process using the AccessWave Management
System.


NOTE: If the invoke operation fails, see Invoke failure for
information.
12. Select Administration from the View menu.
13. In the System pane, click Software Upgrade.
14. In the Upgrade Settings panel, verify that Release 7.3.1 is specified in the
Active Release Number field.
15. Click Commit.
The SYSUPGRDPROG alarm clears, Release 7.3.1 is specified in the
Active Release Number field, and Release 7.2.1 is specified in the Inactive
Release Number field.


NOTE: If the commit operation fails, see Committing Failure
for information.
16. When a system-level upgrade has been completed, you must perform a cold
restart of all 8-port &10-port Multiprotocol Muxponders installed on the
system.
You have successfully completed this procedure.
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-16 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Loading, Invoking, and Committing the
System Software Upgrade using TL1
What you need
AccessWave Series CD


NOTE: The AccessWave Series CD contains an encrypted
manifest file, a binary image file, and a readme file. The
manifest file contains a listing of all the software components
contained in the binary image. The manifest file and the
binary image file are required for upgrading the system software.
Prerequisites
See Upgrade Task Flow and Before you Upgrade to Release 7.3.1.


IMPORTANT: Review the "Troubleshooting" chapter of the
Solutions Guide for each module type installed on the system
for information about additional procedures that might be
required during or after the system software upgrade.
You must be logged on to the system.
If you are using an external FTP server to access the AccessWave Series
CD, the FTP root directory must be configured to serve files from the CD, or
the CD files must be copied to the FTP root directory.
The FTP server and the AccessWave Series system must have IP
connectivity.
There are no CONTCOM alarms on the system.
Recommendations
The state of the AccessWave Series system is In Service.
Remove or install modules during the upgrade process only if you are
instructed to do so.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-17

To load, invoke, and commit the system software upgrade
to Release 7.3.1 using TL1:
1. Insert the AccessWave Series CD into the CD-ROM drive of the FTP
server, and connect to the server.
2. Enter the following at the TL1 command line interface to verify that the
correct software file is available:
CHCK-SYS-UPGRD:[TID]::<CTAG>:::IPADDR=<IPADDR>,[PATH=<PATH>],
[USERID=<USERID>],[PWD=<PWD>];
where
<IPADDR> is the IP address of the server where Release 7.3.1 of the system
software is stored
<PATH> is the directory path to the upgrade software


NOTE: If Release 7.3.1 of the system software is stored in the
root directory of the FTP server, the PATH parameter is not
required.
<USERID> is the user ID for the FTP server
<PWD> is the password assigned to the user ID
For example,
CHK-SYS-UPGRD:AccessWave Series::100::IPADDR=112.23.45.62;
AccessWave Series 2008-01-21 14:00:41

M100 COMPLD
;
AccessWave Series>
AccessWave Series 2008-01-21 14:00:42
A8 REPT EVT EQPT "SCP-1-3:SYSCHKPASS,,2008-01-21,14-00-
43,,,,,:\"Check Upgrade Completed Successfully.\",,,:,"
;

NOTE: If the check operation fails, see Checking Failures for
information.
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-18 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

3. Enter the following at the TL1 command line interface to load Release
7.3.1 of thesystem software:
LOAD-SYS-UPGRD:[TID]::CTAG:::IPADDR=<IPADDR>;
where
<IPADDR> is the IP address where Release 7.3.1 of the system software is
stored For example,

LOAD-SYS-UPGRD:AccessWave Series::100:::IPADDR=112.23.45.62;
AccessWave Series 2008-01-21 14:20:41 M100 COMPLD
;
AccessWave Series>
AccessWave Series 2008-01-21 14:22:10
A7 REPT EVT EQPT
"SCP-1-5:SYSLOADPASS,,2008-01-21,14-22-09,,,,,:\"Software
Load Completed Successfully.\",,[/] [192.168.172.110] ,:,"
;
Release 7.3.1 of the system software takes several minutes to load. Note: if
the load operation fails, see Loading Failures for information.
4. Enter the following at the TL1 command line to verify that Release 7.2.1 is
stored in the active software bank and that Release 7.3.1 of the system
software is stored in the inactive software bank:
RTRV-SYS-RELNUM:[TID]::<CTAG>;
For example,

RTRV-SYS-RELNUM:AccessWave Series::100; AccessWave Series
2008-01-21 14:22:30
M100 COMPLD
"ACTIVE=7.1.1,INACTIVE=7.1.2,"
;
5. Enter the following at the TL1 command line interface to invoke the system
software upgrade:
INVK-SYS-
UPGRD:[TID]::<CTAG>:::RELNUM=<relnum>,[CHKALM=<chkalm>];
where
<RELNUM> is the release number of the system software <CHKALM> is Y or
N
For example,
INVK-SYS-UPGRD:AccessWave
Series::100:::RELNUM=7.1.2,CHKALM=N;
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-19

The SYSUPGRDPROG (System Software Upgrade in Progress) alarm
is raised, and its severity is Minor.
The modules in the system are loaded with the upgraded system software.
The alarm severity changes from Minor to Major and the system then
restarts, starting with the SCP and followed by the modules, and then
the TL1 session ends.


IMPORTANT: The amount of time that the invoke operation
takes to complete depends on the configuration of the node.
For example, for a full four-shelf system, the invoke
operation may take up to one hour to complete.


NOTE: During re initialization, the red Fail LED on each
module may light temporarily while the green Active LED is
lit.
6. When the red Fail LEDs turn off, log on to the system.


NOTE: It can take several minutes to connect to the system.
7. Enter the following at the TL1 command line interface to check the severity
of the SYSUPGRDPROG alarm:
RTRV-ALM-ALL:[TID]::CTAG::,,,,,;
For example,
RTRV-ALM-ALL:AccessWave Series::100::,,,,,;
If the severity of the SYSUPGRDPROG alarm is MJ (Major), the
system
upgrade is still in progress. Use the RTRV-ALM-ALL command to
check the severity of SYSUPGRDPROG alarm until the severity
changes to MN (Minor), which indicates that the system upgrade is
complete, and then proceed to the next step.
If the severity of the SYSUPGRDPROG alarm is MN (Minor), the system
upgrade is complete. Proceed to the next step.


NOTE: At this point, you may cancel the software system
upgrade if necessary and revert to Release 7.2.1 of the system
software. For information, see Cancelling a System Software
Upgrade Process using TL1.


NOTE: If the invoke operation fails, see Invoking Failure for
information.
Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-20 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

8. Enter the following syntax at the TL1 command line interface to verify that
Release 7.3.1 of the system software is stored in the active software bank.
RTRV-NETYPE:[TID]::CTAG;
For example,
RTRV-NETYPE:AccessWave Series::100;
AccessWave Series 2008-01-21 15:20:31
M100 COMPLD
AccessWave Series,AW-60,WDM,7.1.2 ;
9. Enter the following at the TL1 command line interface to commit the
upgrade:
CMMT-SYS-UPGRD:[TID]::CTAG::;
For example,
CMMT-SYS-UPGRD:AccessWave Series::100::;
The SYSUPGRDPROG alarm clears. Optionally, you can use the RTRV-
SYS-RELNUM command to verify that Release 7.3.1 of the system software
is stored in the active software bank and that Release 7.2.1 is stored in the
inactive software bank.
For example,
RTRV-SYS-RELNUM:AccessWave Series::100; AccessWave Series
2008-01-21 16:22:30
M100 COMPLD
"ACTIVE=7.1.2,INACTIVE=7.1.1,"
;


NOTE: If the commit operation fails, see Committing Failure
for information.
10. When a system-level upgrade has been completed, you must perform a cold
restart of all 8-port &10-port Multiprotocol Muxponders installed on the
system.
Enter the following at the TL1 command line interface to restart a module:
INIT-SYS:[TID]:[AID]:CTAG::1:CMDMDE=FRCD;
For example:
INIT-SYS:AW60:MXP-1-1:100::1:CMDMDE=FRCD;

AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Upgrading to Release 7.3.1

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 2-21

Equipment Installing and
Provisioning
After the upgrade to Release 7.3.1 is committed, any new shelves and modules
to be deployed can be added and provisioned. For information, see the
following documents:
Common Equipment Installation Guide
Operations Solution Guide
Solutions Guide for the module portfolio
Auto-upgrade Support on
Modules
All modules (that is, Transponders, Muxponders, Optical Amplifiers, DCMs,
and Multiplexers) ship with pre-loaded software. When a module is inserted
into a shelf, the module software release number is checked to determine if it
matches that of the system software. The module software is automatically
upgraded if it is an earlier version than the system software.
During an auto upgrade, the following occurs:
The UPGRDPROG minor alarm is raised.
The module upgrade starts.
The module initializes.
The UPGRDPROG alarm clears.


IMPORTANT: Review the "Troubleshooting" chapter of the
Solutions Guide for a module portfolio for information about
additional procedures that might be required after an auto-
upgrade is completed.


Upgrading to Release 7.3.1 AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

2-22 ECI Telecom Ltd. Proprietary 426006-2423-023-A00






426006-2423-023-A00 ECI Telecom Ltd. Proprietary 3-1

This section provides information about returning the AccessWave Series to an
earlier version of the system software.
Cancelling a System Software
Upgrade Process using the
AccessWave Management
System
Prerequisites
You must be logged into the system using the AccessWave Management
System.
The invoke operation of the system software upgrade process has been
performed.
The commit operation of the system software upgrade process has not been
performed.
All modules, including the SCP, have been upgraded and reinitialized.
The SYSUPGRDPROG (System Software Upgrade in Progress) alarm is
raised and its severity is Minor.
3
Returning to an Earlier
Version of the System
Software
Returning to an Earlier Version of
the System Software
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

3-2 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

To cancel a system software upgrade process using the
AccessWave Management System:
1. In the Alarms pane, verify that a SYSUPGRDPROG (System Software
Upgrade in Progress) alarm is raised and its severity is Minor.
2. Select Administration from the View menu.
3. In the System pane, click Software Upgrade.
4. In the Upgrade Settings panel, verify that Release 7.3.1 is specified in the
Active Release Number field and Release 7.2.1 is specified in the Inactive
Release Number field.
5. Click Cancel.
The SYSUPGRDPROG alarm changes to Major, the system restarts,
starting with the SCP and followed by the modules, and then the
AccessWave Management System session ends.


NOTE: During re initialization, the red Fail LED on each
module may light temporarily, while the green Active LED is
lit.
6. When the red Fail LEDs turn off, start the AccessWave Management
System, and log on to the system.


NOTE: It can take several minutes to connect to the system.
7. In the Alarms pane, verify that the SYSUPGRDPROG alarm has cleared.
8. Select Administration from the View menu.
9. In the System pane, click Software Upgrade.
10.
In the Upgrade Settings panel, verify that Release 7.2.1

is specified in the
Active
Release Number field and Release 7.3.1 is specified in the Inactive
Release Number field.


NOTE: If the cancel operation fails, see Cancelling Failure for
information.
You have successfully completed this procedure.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Returning to an Earlier Version of
the System Software

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 3-3

Cancelling a System Software
Upgrade Process using TL1
Prerequisites
You must be logged into the system.
The invoke operation of the system software upgrade process has been
performed.
The commit operation of the system software upgrade process has not been
performed.
All modules, including the SCP, have been upgraded and reinitialized.
The SYSUPGRDPROG (System Software Upgrade in Progress) alarm is
raised and its severity is Minor.
To cancel a system software upgrade process using TL1:
1. Enter the following syntax at the TL1 command line interface to verify that
a SYSUPGRDPROG (System Software Upgrade in Progress) alarm is raised
and its severity is Minor:
RTRV-ALM-ALL:[TID]::CTAG::,,,,,;
2. Enter the following syntax at the TL1 command line interface to cancel the
system software upgrade and confirm that the SYSUPGRDPROG alarm
clears.
CANC-SYS-UPGRD:[TID]::CTAG;
For example,
CANC-SYS-UPGRD:AccessWave Series::100;
The system returns the following message:
AccessWave Series 2008-01-31 14:28:35
A10 REPT ALM EQPT
"SCP-1-5,CL,SYSUPGRDPROG,NSA,2008-01-31,14-28-35,,,,,,\"Clear
Software Upgrade In Progress.\",,,,,"
;
The system restarts, starting with the SCP and followed by the modules,
and then the TL1 session ends.


NOTE: During re initialization, the red Fail LED on each
module may light temporarily, while the green Active LED is
lit.
Returning to an Earlier Version of
the System Software
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

3-4 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

3. When the red Fail LEDs turn off, log on to the system.


NOTE: It can take several minutes to connect to the system.
4. Enter the following syntax at the TL1 command line interface to verify that
Release 7.2.1 is stored in the active software bank and Release 7.3.1 is
stored in the inactive software bank.
RTRV-SYS-RELNUM:[TID]::<CTAG>;
For example,
RTRV-SYS-RELNUM:AccessWave Series::100;
The system returns the following message:

AccessWave Series 2008-01-31 14:28:45W
M100 COMPLD
"ACTIVE=7.1.1,INACTIVE=7.1.2,"
;


NOTE: If the cancel operation fails, see Cancelling Failure for
information.

You have successfully completed this procedure.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Returning to an Earlier Version of
the System Software

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 3-5

Downgrading the System
Software using the AccessWave
Management System

Prerequisites
See the Release Notes for Release 7.3.1 for information about downgrading
the system software.
You must be logged on to the system using Release 7.3.1 of the
AccessWave Management System.
There are no CONTCOM alarms on the system.
Recommendations
The state of the AccessWave Series system is In Service.
Remove or install modules during the downgrade process only if you are
instructed to do so.
To downgrade the system software using the AccessWave
Management System:


IMPORTANT: Any modifications provisioned on the system
while Release 7.3.1 of the system software was running will be
lost.


NOTE: If there are no active modules on the system, database
recovery is not possible.
1. Select Administration from the View menu.
2. In the System pane, click Software Upgrade to display the upgrade
settings.
3. In the Upgrade Settings panel, verify that Release 7.2.1 is specified in the
Inactive Release Number field.
Returning to an Earlier Version of
the System Software
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

3-6 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

4. If alarms are present on the system, select the Ignore Alarms check box in
the Upgrade Settings panel.


IMPORTANT: The system software downgrade will not
proceed if alarms are present on the system and the Ignore
Alarms check box has not been selected.
5. Click Invoke.
The SYSUPGRDPROG (System Software Upgrade in Progress) is
raised, and its severity is Minor.
The modules in the system are loaded with Release 7.2.1 of the system
software. The alarm severity changes to Major, and the system then
restarts, starting with the SCP and followed by the modules, and then
the AccessWave Management System session ends.


IMPORTANT: The amount of time that the invoke operation
takes to complete depends on the configuration of the node.
For example, for a full four-shelf system, the invoke
operation may take up to one hour to complete.


NOTE: During re-initialization, the red Fail LED on each
module may light temporarily while the green Active LED is
lit.
6. When the red Fail LEDs turn off, start the AccessWave Management
System, and log on to the system.


NOTE: It can take several minutes to connect to the system.
7. In the Alarms pane, check the severity of the SYSUPGRDPROG alarm.
If the severity of the SYSUPGRDPROG alarm is Major, the system
downgrade is still in progress. Wait until the severity of the
SYSUPGRDPROG alarm changes to Minor, which indicates that the
system downgrade is complete, and then proceed to the next step.
If the severity of the SYSUPGRDPROG alarm is Minor, the system
downgrade is complete. Proceed to the next step.


NOTE: If the invoke operation fails, see Invoking Failure for
information.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Returning to an Earlier Version of
the System Software

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 3-7

8. Select Administration from the View menu.
9. In the System pane, click Software Upgrade.
10. In the Upgrade Settings panel, verify that Release 7.2.1 is specified in the
Active Release Number field and Release 7.3.1 is specified in the Inactive
Release Number field.
11. Click Commit.
The SYSUPGRDPROG alarm clears, Release 7.2.1 is specified in the
Active Release Number field, and Release 7.3.1 is specified in the
Inactive Release Number field.


NOTE: If the commit operation fails, see Committing Failure
for information.
You have successfully completed this procedure.
Downgrading the System Software
using TL1

Prerequisites
See the Release Notes for Release 7.3.1 for information about downgrading
the system software.
You must be logged on to the system.
There are no CONTCOM alarms on the system.
Recommendations
The state of the AccessWave Series system is In Service.
Remove or install modules during the downgrade process only if you are
instructed to do so.
Returning to an Earlier Version of
the System Software
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

3-8 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

To downgrade the system software using TL1:


IMPORTANT: Any modifications provisioned on the system
while Release 7.3.1 of the system software was running will be
lost.


NOTE: If there are no active modules on the system, database
recovery is not possible.
1. Enter the following at the TL1 command line to verify that Release 7.2.1 of
the system software is stored in the inactive software bank and Release
7.3.1 is stored in the active software bank:
RTRV-SYS-RELNUM:[TID]::<CTAG>;
For example,
RTRV-SYS-RELNUM:AccessWave Series::100; AccessWave Series
2008-01-21 14:22:30
M100 COMPLD
"ACTIVE=7.1.2,INACTIVE=7.1.1," ;
2. Enter the following at the TL1 command line interface to invoke the system
software downgrade:
INVK-SYS-
UPGRD:[TID]::CTAG::[RELNUM=<RELNUM>],[CHKALM=<CHKALM>];
where
<RELNUM> is the release number of the system software
<CHKALM> is Y or N
For example,
INVK-SYS-UPGRD:AccessWave Series::100::RELNUM=7.1.1,CHKALM=N;


IMPORTANT: The CHKALM parameter must be set to N for
the downgrade to proceed as the RELNUMSWMEA alarm is raised.
The SYSUPGRDPROG (System Software Upgrade in Progress) alarm is
raised, and its severity is Minor.
The modules in the system are loaded with the upgraded system software. The
alarm severity changes to Major, and the system then restarts, starting with
the SCP and followed by the modules, and then the TL1 session ends.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Returning to an Earlier Version of
the System Software

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 3-9



IMPORTANT: The amount of time that the invoke operation
takes to complete depends on the configuration of the node.
For example, for a full four-shelf system, the invoke operation
may take up to one hour to complete.


NOTE: During re initialization, the red Fail LED on each
module may light temporarily while the green Active LED is
lit.
3. When the red Fail LEDs turn off, log on to the system.
4. Enter the following at the TL1 command line interface to check the severity
of the SYSUPGRDPROG alarm:
RTRV-ALM-ALL:[TID]::CTAG::,,,,,;
For example,
RTRV-ALM-ALL:AccessWave Series::100::,,,,,;
If the severity of the SYSUPGRDPROG alarm is MJ (Major), the
system downgrade is still in progress. Use the RTRV-ALM-ALL
command to check the severity of the SYSUPGRDPROG alarm until the
severity changes to MN (Minor), which indicates that the system
downgrade is complete, and then proceed to the next step.
If the severity of the SYSUPGRDPROG alarm is MN (Minor), the
system downgrade is complete. Proceed to the next step.


NOTE: If the invoke operation fails, see Invoking Failure for
information.
5. Enter the following at the TL1 command line interface to verify that
Release 7.2.1 of the system software is stored in the active software bank:
RTRV-NETYPE:[TID]::CTAG;
For example,
RTRV-NETYPE:AccessWave Series::100;
AccessWave Series 2008-01-21 15:20:31
M100 COMPLD
AccessWave Series, AW-60,WDM,7.1.1 ;
6. Enter the following at the TL1 command line interface to commit the
downgrade:
CMMT-SYS-UPGRD:[TID]::CTAG::;
For example,
CMMT-SYS-UPGRD:AccessWave Series::100::;
Returning to an Earlier Version of
the System Software
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

3-10 ECI Telecom Ltd. Proprietary 426006-2423-023-A00


NOTE: If the commit operation fails, see Committing Failure
for information.
The SYSUPGRDPROG alarm clears. Optionally, you can use the RTRV-
SYS-RELNUM command to verify that Release 7.2.1 of the system
software is stored in the active software bank and that Release 7.3.1 is
stored in the inactive software bank.
For example,
RTRV-SYS-RELNUM:AccessWave Series::100; AccessWave Series
2008-01-21 16:22:30
M100 COMPLD
"ACTIVE=7.1.1,INACTIVE=7.1.2," ;


NOTE: If the commit operation fails, see Committing Failure
for information.
You have successfully completed this procedure.


426006-2423-023-A00 ECI Telecom Ltd. Proprietary 4-1

This section provides information about other procedures you can perform
when upgrading to Release 7.3.1.
Determining System Software
Release Numbers
To determine the system software release number using the
BNC or the AccessWave Management System:
1. Select Administration from the View menu.
2. In the System pane, select Software Upgrade.
System release number information is provided in the Active Release
Number and Inactive Release Number fields.
4
Useful Procedures
Useful Procedures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

4-2 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Determining the System Software Release Number
using TL1
The following table lists the TL1 commands that retrieve system software
release numbers.
Command Release retrieved
RTRV-NETYPE Active release
RTRV-SYS-RELNUM Active release and Inactive release
Database Restoring using the
AccessWave Management
System
What you need
Backup file of the database
Prerequisites
The database backup file corresponds to the network element to which it
will be restored.


NOTE: If restoring a database with communication port
settings that are different from the current settings,
connectivity can be lost. After the database restore operation
is completed, reconnect using the communication port
settings specified in the restored database.


IMPORTANT: Equipment provisioning cannot be performed
during a database restore operation.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Useful Procedures

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 4-3

To restore the database using the AccessWave Management
System:
1. Select Administration from the View menu.
2. In the System pane, click Database Restore.
3. In the Load Settings panel, do one of the following:
Choose Local PC to load a database backup file stored on the local PC,
and then click Browse to navigate to and select the file.
Choose Remote PC to load a database backup file stored on an FTP
server, enter the IP address of the FTP server, enter a user ID and a
password in the FTP User ID and FTP Password fields, respectively, and
then enter path to the file, including the file name, in the File field.


NOTE: Some UNIX systems may require you to enter the
entire directory path and the database file name in the File
field.


NOTE:
Windows users should use a UNIX style directory
name on a Windows FTP
server. For example, if the files are
stored in C:/Program Files/FTP Server/Files, omit the C: and
enter the path as /Program Files/FTP Server/Files.
Choose SCP to load the database backup file stored on the SCP.
4. Click Load.
The file name of the database backup file appears in the Status window of
the Database Restore Settings panel.
5. Click Invoke.
6. Do one of the following:
a. Click Accept, and then proceed to the next step.
b. Click Cancel to cancel the database restore operation.


NOTE: Cancelling the database restore operation causes the
system to restart and all AccessWave Management System
sessions to end.
7. Click Commit to restore the database
Messages indicating the progress of the database restore operation appear
in the Status window.
If the database restore operation is successful, the message Restore
Process Completed Successfully appears. If the operation fails, an
error message appears.
You have successfully completed this procedure.
Useful Procedures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

4-4 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Database Restoring using TL1
What you need
Backup file of the database
Prerequisites
All alarms on the system have been cleared.
The database backup file corresponds to the network element to which it
will be restored.


NOTE: If restoring a database with communication port
settings that are different from the current settings, connectivity
can be lost. After the database restore operation is completed,
reconnect using the communication port settings specified in the
restored database.


IMPORTANT: Equipment provisioning cannot be performed
during a database restore operation.
To restore the database using TL1:
1. Enter the following syntax at the TL1 command line interface to load the
database file:
LOAD-DB-RST:[TID]::<CTAG>:::TYPE=<TYPE>,[IPADDR=<IPADDR>],
[PATH=<PATH>],[USERID=<USERID>],[PWD=<PWD>],[TIDCHK=<TIDCHK>]
;
where
<TYPE> is FTP or SCP
<IPADDR> is the address of the FTP server where the backup file is stored
<PATH> is the path to the database backup file, including the file name


NOTE: The value <PATH> can contain a maximum of 54
alphanumeric characters when TYPE=FTP and 48 alphanumeric
characters when TYPE=SCP.


NOTE: Some UNIX systems may require you to enter the
entire directory path and the database file name.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Useful Procedures

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 4-5

<USERID> is the user ID for the FTP server
<PWD> is the password assigned to the user ID <TIDCHK> is Y or N
If the value <PATH> includes the TID, the TID in the database file name must
match the TID of the system. However, if the default file name is changed,
set the parameter TIDCHK to N.
The system returns the following message:
NYC101 06-01-28 06:22:01
M100 COMPLD
;
AccessWave Series>
NYC101 06-01-28 06:22:03
A3 REPT EVT EQPT
"SCP-1-5:DBLOADPASS,,06-01-28,06-22-02,,,,,:\"Database Load
Completed Successfully.\",,\"[AccessWave
Series_NYC101_January24_2006] [10.
1.1.100]\",:,"
;
2. Enter the following syntax at the TL1 command line to retrieve the
database file:
RTRV-DB-RST:[TID]::<CTAG>;
For example,
RTRV-DB-RST:NYC101::100;
The system returns the following message, which indicates the name of the
database file that is loaded:
NYC101 06-01-28 06:22:02
M100 COMPLD
"[AccessWave Series_NYC101_January24_2006]";
;
3. Enter the following syntax at the TL1 command line to invoke the database
restore process:
INVK-DB-RST:[TID]::<CTAG>:::FILENAME=<FILENAME>,
[CHKALM=<CHKALM>];
where
<FILENAME> is the name of the database file <CHKALM> is Y or N

Useful Procedures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

4-6 ECI Telecom Ltd. Proprietary 426006-2423-023-A00


NOTE:
The system defaults to the following format for the file name:
AccessWave Series_<NEName>_<MONTH><DAY>_<YEAR>. For
the file name to function correctly, one or more alphabetic characters
and the underscore must precede <NEName>.
For example,
INVK-DB-RST:AccessWave Series::100:::
_NYC101_January24_2006,CHKALM=N;
The system returns the following message:
NYC101 06-01-28 06:23:05
M100 COMPLD
;
AccessWave Series>
NYC101 03-01-28 06:23:06 ** 4 REPT ALM EQPT
"SCP-1-5,MJ,DBRSTPROG,NSA,06-01-28,06-23-05,,,,,:\"Database
Restore In Progess.\",,,:,"
;
NYC101 03-01-28 06:23:06
A5 REPT EVT EQPT
"SCP-1-5:INVKDBRSTPASS,,06-01-28,06-23-05,,,,,:\"Invoke
Database Restore Completed Successfully.\",,,:," ;
4. Do one of the following:
a. To accept the database file, enter the following syntax at the TL1
command line interface, and then proceed to the next step:
ACPT-DB-RST:[TID]::<CTAG>;
For example,
ACPT-DB-RST:NYC101::100;
The system returns the following message:
NYC101 06-01-28 06:23:32
M FD COMPLD
;
AccessWave Series>
NYC101 06-01-28 06:23:33
A6 REPT EVT EQPT
"SCP-1-5:APPLDBRSTPASS,,06-01-28,06-23-32,,,,,:\"Apply
Database Restore Completed Successfully.\",,,:," ;
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Useful Procedures

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 4-7

b. To cancel the database restore operation, enter the following at the TL1
command line interface:
CANC-DB-RST:[TID]::<CTAG>;
For example,
CANC-DB-RST:NYC101::100;
The system returns the following message:
NYC101 06-01-28 06:23:54
A21 REPT ALM EQPT
"SCP-1-5,CL,DBRSTPROG,NSA,06-01-28,06-23-54,,,,,,\"Clear
Database Restore In Progress.\",,,,,"
;


NOTE: Cancelling the database restore operation causes the
system to restart and all TL1 sessions to end.
5. Enter the following at the TL1 command line interface to commit the
database restore operation:
CMMT-DB-RST:[TID]::<CTAG>;
For example,
CMMT-DB-RST:NYC101::100;
The system returns the following message:
AccessWave Series>
06-01-28 06:23:54 M 100 COMPLD
;
You have successfully completed this procedure.
Useful Procedures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

4-8 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Establishing an AccessWave
Management System Session
using Ethernet
Use Method One: Connecting through the Management LAN, or Method Two:
Connecting through the Craft LAN Port to establish an Ethernet connection to
the AccessWave Series system.


NOTE: The same functions are available through the craft
LAN and the management LAN interfaces.
The following table lists the IP addresses for the AccessWave Series LAN
communication ports.
Table 4-1: IP Addresses
Communications
Port
Default IP
Address
Default IP MaskDefault IP
Gateway
Default IP Addresses:
Management LAN
Port
10.0.0.1 255.0.0.0 0.0.0.0
Craft LAN Port192 192168.17.1 1255.255.255.0 0.0.0.0
For a PC Connected To:
1

Management LAN
Port
10.x.y.z
2
255.0.0.0
Craft LAN Port 192.168.17.z
3

255.255.255.0
1
You do not need to configure a default gateway on the PC.
2
Where x and y are 0 to 255, and 2 z 254
3
Where 2 z 254


NOTE: The Ethernet ports are set to Auto-Negotiate. To ensure
optimum communication between the AccessWave Series
system and your equipment, ECI Telecom recommends that
you set your equipment to Auto-Negotiate, as well.
You do not need to configure a default gateway on the PC.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Useful Procedures

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 4-9

The following illustrations shows the two methods to use when establishing an
AccessWave Management System session using Ethernet.

Figure 4-1: Establishing an AccessWave Management System session using
Ethernet

Figure 4-2: Establishing an AccessWave Management System session using
Ethernet
Useful Procedures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

4-10 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Method One: Connecting through the
Management LAN

Prerequisites
To connect a PC directly to the management LAN port on the shelf, you
require a CAT 5 shielded, grounded Ethernet cable of sufficient length with
RJ-45 male connectors.
The Ethernet LAN ports automatically determine what device is attached, and
they automatically configure the input and output signals for the Ethernet
cable used.
To connect to the AccessWave Series equipment through
the management LAN:
1. Provision the IP Address
If not yet configured, provision the shelf with the IP address of your
intended management Ethernet LAN.
2. Connect the AccessWave Series Ethernet Cables
Insert one end of a shielded and grounded Ethernet cable in the
management LAN port.
Insert the other end of the shielded and grounded Ethernet cable in the RJ-
45 female Ethernet LAN connector on your hub or switch.
3. Connect the Computer Ethernet Cables
Insert one end of a shielded and grounded Ethernet cable in the RJ-45
female Ethernet LAN connector on your PC.
Insert the other end of the shielded and grounded Ethernet cable in the RJ-
45 female connector of your management LAN.
4. Start an AccessWave Management System Session
5. Log on to the AccessWave Series using the AccessWave Management
System
You have successfully completed this procedure.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Useful Procedures

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 4-11

Method Two: Connecting through the Craft
LAN Port

Prerequisites
None
To connect to the AccessWave Series shelf through the craft
LAN port:
1. Provision the IP Address
If not yet configured, provision the AccessWave Series shelf with the IP
address of your intended craft Ethernet LAN.
2. Connect the Ethernet Cable
Insert one end of the shielded and grounded Ethernet cable in the craft LAN
port.
Insert the other end of the shielded and grounded Ethernet cable in the RJ-
45 female Ethernet LAN connector on your PC or laptop.
3. Start an AccessWave Management System Session
4. Log on to the AccessWave Series using the AccessWave Management
System
You have successfully completed this procedure.
Useful Procedures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

4-12 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Establishing a TL1 Session using
RS-232


Figure 4-3: Establishing a TL1 session using the RS-232 Craft serial port

Figure 4-4: Establishing a TL1 session using the RS-232 Craft serial port
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Useful Procedures

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 4-13

To connect a PC to an AccessWave Series shelf through the
RS-232 craft serial port on the shelf:
1. Connect the RS-232 Cable.
Insert one end of the RS-232 cable in the craft serial port on the
AccessWave Series shelf.
Insert the other end of the RS-232 cable in the RS-232 male connector on
your PC or laptop.
2. Set the RS-232 Parameters
Set the default RS-232 parameters for the PC to match the AccessWave
Series shelf:
Rate: 9600 bps
Data Bits: 8 bits
Parity: None
Stop Bits: 1 bit
Flow Control: None
3. Establish a TL1 Session
From a terminal emulator, establish a TL1 session to the AccessWave
Series shelf by pressing the Return key.
Response
The system responds with the system prompt.
4. Log on to the AccessWave Series
To log on to the AccessWave Series, enter the following at the TL1
command line interface:
ACT-USER:[TID]:<uid>:<CTAG>::<pid>;
where
TID is the target identifier (AccessWave Series is the default target
identifier)
uid is the user identifier (admin is the default system administrator uid)
CTAG is the correlation tag (100 is the default correlation tag)
pid is the password identifier (admin is the default system administrator
pid). Note: User identifier admin and password identifier admin
are the default system administrator credentials.
Example
ACT-USER:AccessWave Series:admin:100::*****;
Response
The AccessWave Series sends back a COMPLD message to indicate a
successful log on.
You have successfully completed this procedure.
Useful Procedures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

4-14 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

RS-232 Serial Communications
The AccessWave Series system has a craft serial port that uses the RS-232
protocol.
Cables Required
When connecting a PC or laptop to the craft serial port, use a straight-through
RS-232 cable with a DB-9 pin male connector.
If you anticipate using the RS-232 serial port, determine the length of cable
required to connect the AccessWave Series system to your PC, and prepare the
cable with the appropriate male connector.
RS-232 Pin Assignment
The following figure shows the RS-232 DB-9 pin DCE connector as well as the
RS-232 RJ-45 8 pin connector and the associated pin numbering schemes.

Figure 4-5: DB-9 Pin Connector and 8 Pin RJ-45 Connector Numbering Schemes
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Useful Procedures

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 4-15

The following table lists the RS-232 pin assignment for the DB-9 pin connector
and RJ-45 connector pin numbering schemes.
Table 4-2: Pin Assignments for RS-232 DB-9 Pin Connectors and RS-232 RJ-45
Connectors
DB-9 Pin
Connector
DCE Purpose RJ-45
Connector
DCE Purpose
1 Data Terminal Ready 1 Request to Send
2 Transmitted Data 2 Data Terminal Ready
3 Received Data 3 Transmitted Data
4 DTE Ready 4 Signal Ground
5 Signal Ground 5 Signal Ground
6 DCE Ready 6 Received Data
7 Clear to Send 7 Data Carrier Detect / Data
Set Ready
8 Request to Send 8 Clear to Send
9 Ring Detector

Useful Procedures AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

4-16 ECI Telecom Ltd. Proprietary 426006-2423-023-A00






426006-2423-023-A00 ECI Telecom Ltd. Proprietary 5-1

This section provides information about troubleshooting the issues that might
arise when upgrading from Release 7.2.1 to Release 7.3.1.
Checking Failures
CHK-SYS-UPGRD Failure when File is not
found on FTP Server
AccessWave Series 2008-04-29 08:46:47
A 17538 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,2008-04-29,08-46-46,,,,,:Check Upgrade
Failure. Requested operation failed. No FTP file found.,,,:,"
;
CHK-SYS-UPGRD Failure when FTP Server is
not Found
AccessWave Series 2008-04-29 08:49:16
A 17539 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,2008-04-29,08-49-15,,,,,:Check Upgrade
Failure. Requested operation failed. FTP Server not
available.,,,:,"
;
5
Troubleshooting
Troubleshooting AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

5-2 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

CHK-SYS-UPGRD Failure when Inventory
does not Match Load
AccessWave Series 2008-04-30 08:47:26
A 17762 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,2008-04-30,08-47-25,,,,,:Check Upgrade
Failure. Inventory does not match Load provided.,,,:," ;
CHK-SYS-UPGRD Failure when an Invalid
Manifest File is Found
AccessWave Series 2008-04-30 08:55:34
A 17763 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,2008-04-30,08-55-33,,,,,:Check Upgrade
Failure. Invalid Manifest file found.,,,:,"
CHK-SYS-UPGRD Failure when an Invalid
Username or Password is Found
AccessWave Series 06-12-19 10:55:45
A529 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,12-19,10-55-44,,,,,:\"Check Upgrade
Failure. Invalid username or password.\",,,:," ;
CHK-SYS-UPGRD Failure when the Wrong
FTP Server is Accessed
AccessWave Series 06-12-19 10:42:01
A516 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,12-19,10-42-00,,,,,:\"Check Upgrade
Failure. Requested operation failed. Internal system fault.
\",,,:,"
;
CHK-SYS-UPGRD Failure when the Wrong
Path is Specified
AccessWave Series 06-12-19 10:58:20
A536 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,12-19,10-58-19,,,,,:\"Software Load
Failed. File does not exists.\",,,:,"
;
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Troubleshooting

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 5-3

CHK-SYS-UPGRD Failure when Another Load
or CHK-SYS-UPGRD was Already Started
AccessWave Series 06-12-19 10:50:09
A524 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,12-19,10-50-08,,,,,:\"Check Upgrade
Failure. Invalid Upgrade Sequence.\",,,:," ;
CHK-SYS-UPGRD Failure when Gateway is
not Set and IP Address is Outside the IP-
NMS Subnet
AccessWave Series 06-12-19 13:37:28
A9 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,12-19,13-37-26,,,,,:\"Check Upgrade
Failure. No route to host.\",,,:,"
;
CHK-SYS-UPGRD Failure when you do not
Have Read Permission on the FTP Server
AccessWave Series 06-12-19 13:52:37
A12 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,12-19,13-52-36,,,,,:\"Check Upgrade
Failure. Permission denied.\",,,:,"
;
Troubleshooting AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

5-4 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Loading Failures
LOAD-SYS-UPGRD Failure when a
Handshake Failure to the FTP Server Occurs
AccessWave Series 2003-04-29 08:58:26
A 17364 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,2003-04-29,08-58-25,,,,,:\"Software
Load Failed.\"Requested operation failed. FTP Not
Defined.,,,:," ;
LOAD-SYS-UPGRD Failure when File is not
Found on FTP Server
AccessWave Series 2003-04-29 08:58:26
A 17544 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,2003-04-29,08-58-25,,,,,:\"Software
Load Failed.\"Requested operation failed. No FTP file
found.,,,:," ;
LOAD-SYS-UPGRD Failure when FTP Server
is not Found
AccessWave Series 2003-04-29 08:59:04
A 17545 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,2003-04-29,08-59-03,,,,,:\"Software
Load Failed.\"Requested operation failed. FTP Server not
available.,,,:,"
;
LOAD-SYS-UPGRD failure when an invalid FTP server IP address
is specified
AccessWave Series 06-12-19 11:09:16
M100 DENY
IDNV
/* Data not valid. Invalid Address. Error #2819. */
;
LOAD-SYS-UPGRD failure when valid but wrong IP address is
specified and there is no answer from the remote node
AccessWave Series 06-12-19 11:04:02
A537 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,12-19,11-04-01,,,,,:\"Software Load
Failed. Connection to FTP server timed out.\",,,:," ;
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Troubleshooting

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 5-5

LOAD-SYS-UPGRD Failure when there is no
FTP Server Running on the Designated IP
Address
AccessWave Series 06-12-19 11:07:14
A540 REPT EVT EQPT
"SCP-1-5:SYSCHKFAIL,,12-19,11-07-13,,,,,:\"Check Upgrade
Failure. FTP server not available, connection
refused.\",,,:," ;
LOAD-SYS-UPGRD Failure when Trying to
Load while a Load is in Progress
AccessWave Series 2003-04-29 09:00:35
A 17546 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,2003-04-29,09-00-34,,,,,:\"Software
Load Failed. \"Requested operation failed. Upgrade Load
Process Already Started.,,,:,"
;
LOAD-SYS-UPGRD Failure when a Bad Load
is Found
AccessWave Series 2003-04-30 09:00:20
A 17766 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,2003-04-30,09-00-19,,,,,:\"Software
Load Failed.\"Bad Load found.,,,:,"
;
LOAD-SYS-UPGRD Failure when the Invoke
Process is in Progress
AccessWave Series 2003-04-30 09:09:06
A 17771 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,2003-04-30,09-09-05,,,,,:\"Software Load
Failed.\"Requested operation failed. Upgrade Load Process Already
Started.,,,:," ;
Troubleshooting AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

5-6 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

LOAD-SYS-UPGRD Failure when the Inactive
Software Bank has Failed
AccessWave Series 05-04-13 19:22:24
A4 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,04-13,19-22-23,,,,,:\"Software Load
Failed.
Unmapped error code.\",,,:,"
;


NOTE: See the Alarm and Troubleshooting Guide for
information about replacing the SCP.

LOAD-SYS-UPGRD Failure when a Circuit
Pack is Unknown or the Circuit Pack has
Corrupted Inventory Data
AccessWave Series 06-12-19 11:29:45
A547 REPT EVT EQPT
"SCP-1-5:SYSLOADFAIL,,12-19,11-29-44,,,,,:\"Software Load
Failed. Inventory does not match Load provided.\",,,:,"
;
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Troubleshooting

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 5-7

Invoking Failure
TL1 Invoke Failure Messages
When the INVK-SYS-UPGRD command is issued, the software image on the
inactive memory bank becomes active. If the invoke process is unsuccessful,
the system generates an event response message that indicates why the invoke
has failed. Listed below are some examples.
INVK-SYS-UPGRD Failure when Alarms are
Present on the System
AccessWave Series 2008-04-29 09:03:18
M100 DENY
SNVS
/* Not in Valid State. System must be alarm-free. */
;
INVK-SYS-UPGRD Failure when the Release
Number is Already Active
AccessWave Series 2008-04-29 09:03:46
M100 DENY
SROF
/* Upgrade to Requested Release not possible. */
;
INVK-SYS-UPGRD Failure when the System
Upgrade has Already been Invoked
AccessWave Series 2008-04-30 09:08:19
M100 DENY
SROF
/* Requested operation failed. Command not allowed while
upgrade invoke stage is in progress. */
;
or
AccessWave Series 2008-02-31 19:03:44
M100 DENY
SROF
/* Requested Operation Failed. Upgrade In Progress. */
;
Troubleshooting AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

5-8 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

Recommended Actions for Failure Invoking
1. Check for file transfer problems:
If the error message Database Load Failed is returned, check to see if
there has been a problem during the file transfer process. Check that the:
Filename is correct
Correct IP address is entered
FTP server is running
Gateway on the FTP server is correct
FTP server can communicate with the AccessWave Series by pinging the
AccessWave Series from the FTP server
That the path is set correctly. Some UNIX FTP servers require the user to
specify the complete directory path of the file
UNIX permissions are set to global read-write access
There was no network interruption during the system upgrade or database
restore
If no apparent reason can be found for the file transfer failure, contact your
next level of support.
2. Check the Alarms to see if any alarms are present. See the applicable alarm
clearing procedure for instructions to clear the alarm.
3. If an alarm is present and you want to proceed with the Invoke, check to
see if the Ignore Alarms option in the Software Upgrade window, is enabled.
4. If you are using TL1, INVK-SYS-UPGRD command may be blocked.
The following conditions cause the INVK-SYS-UPGRD command to be
blocked:
If alarms are present in the system, the INVK-SYS-UPGRD command
is blocked. Clear the alarms that are present and then proceed with the
INVKSYS-UPGRD command.
If the system has already upgraded to the new product release, the INVK-
SYS-UPGRD command is blocked. You cannot upgrade the system to the
product release that the system is currently running.
If the INVK-SYS-UPGRD command has already been issued, or if an
upgrade is already in progress, the INVK-SYS-UPGRD command is
blocked. A subsequent INVK-SYS-UPGRD command cannot be issued
before the upgrade is completed.
If there is an attempt to downgrade the system software, the INVK-SYS-
UPGRD command is blocked. Contact your next level of support if you
need assistance.
For the scenarios described above, wait for any ongoing commands to
complete and then determine where you are in respect to the current system
status.
If you cannot determine what state the system is in, contact your next level
of support.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Troubleshooting

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 5-9

Committing Failure
CMMT-SYS-UPGRD Failure when the
Software has not Been Loaded or Invoked
.AccessWave Series 2008-04-30 08:52:39
M100 DENY
SROF
/* Requested operation failed. Upgrade ProcessNot Started. */
;
Ensure that you have invoked the system upgrade before issuing the CMMT-
SYS-UPGRD command.
Cancelling Failure
CANC-SYS-UPGRD Failure when an Invoke
has not been Started
AccessWave Series 2007-12-31 19:02:05
M100 DENY
SROF
/* Requested operation failed. Upgrade Process Not Started.
*/
;
CANC-SYS-UPGRD Failure when an Invoke is
in Progress
AccessWave Series 2007-12-31 09:27:38
M100 DENY
SROF
/* Requested operation failed. Command not allowed while
upgrade invoke stage is in progress. */
;
Troubleshooting AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

5-10 ECI Telecom Ltd. Proprietary 426006-2423-023-A00

CANC-SYS-UPGRD Failure after Upgrade has
Already been Cancelled
AccessWave Series 2007-12-31 19:01:34 M100 DENY
SROF
/* Requested operation failed. Upgrade Process Not Started. */
;
Recommended Actions for Cancelling
Failures
The following conditions can cause the CANC-SYS-UPGRD command to be
blocked:
If the INVK-SYS-UPGRD command has not been issued, the CANC-SYS-
UPGRD command is blocked. Issue the INVK-SYS-UPGRD command and
wait for the invoke process to complete before issuing the CANC-SYS-
UPGRD command.
If an invoke operation is in progress, the CANC-SYS-UPGRD command is
blocked. Wait for the invoke process to complete and then issue the
CANC-SYS-UPGRD command.
If the CANC-SYS-UPGRD command has already been issued, the CANC-
SYS-UPGRD command is blocked. There is no need to issue the CANC-
SYS-UPGRD command again.
If you are unable to cancel the upgrade or determine what state the system is in,
contact your next level of support.
Provisioning Failure
ENT-EQPT Failure when a System Software
Upgrade is in Progress
When the ENT-EQPT command is issued during a system software upgrade,
the system attempts to enter new provisioning parameters. With the a system
software upgrade in progress, the system generates an event response message
that indicates that the command is blocked. Listed below is an example.
AccessWave Series 2003-04-30 09:10:19
M100 DENY
SROF
/* Command blocked due to current system access level. */
;
Wait for the a system software upgrade to complete before issuing a
provisioning command.
AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1
Troubleshooting

426006-2423-023-A00 ECI Telecom Ltd. Proprietary 5-11

Module Upgrade Failure
The AccessWave Series confirms when all modules have been successfully
upgraded to a new software release. If a module fails to upgrade properly, the
system raises a Circuit Pack Upgrade Failure alarm (PACKUPGRDFAIL).
This alarm indicates which module failed to upgrade.


NOTE: The module upgrade failure is not a service affecting
condition. The module continues to run its original software
and continues to process optical signals properly.

While the PACKUPGRDFAIL alarm is active, both alarm reporting and
performance monitoring data collection are disabled.
If a module upgrade fails, contact ECI Telecom Support.Chapter 3, Returning
to an earlier version of the system software
Database Recovery Failure
When an SCP is replaced, the new SCP automatically acquires the provisioning
database from an active module in the system. This simplifies the replacement
process because a manual database restore operation is not required.
The AccessWave Series confirms when the SCP has successfully recovered the
database from the system. If the database is not recovered, a Database
Recovery Failure alarm (DBRECVRYFAIL) is raised. In this situation, the
database must be restored manually from a remote FTP server. For information
about clearing this alarm, see the Alarm and Troubleshooting Guide.

Troubleshooting AccessWave Series Upgrade Guide
from V7.1.x or 7.2.1 to 7.3.1

5-12 ECI Telecom Ltd. Proprietary 426006-2423-023-A00