You are on page 1of 4

Architectural Design V Area Programming Report Group V

SiteArea 3acres 12140.6 sqm TypesofTraffic TypeofAccess Description Timings CirculationCharacteristics


GroundCoverage 35% 4249.2 sqm
ProgrammedGroundCoverage 3080 sqm
FAR 1.5
TotalAllowedBuiltUpArea 18210.9 sqm
TotalAreaProgrammed 14456 sqm
Heightoftalleststructure 30 m
Heightofeachfloor(majoritycases) 3.9 (average)
Numberoffloorspossible 7
4 floorsapproximately
CirculationCoefficient 0.3
365 cars
(Incaseofassembly
buildings,2ECS)
36cars
150
TrafficStudy CulturalComplexandSpiritualCentre
SpiritualVisitors Pedestrian/Car
Universalcrowdcouldberichor
poor;
HighDensityAllday
VehicularEntry>Dropoff/To
Parking>Entrytolobbyfromdrop
off/Entrytolobbyfromparking
PedestrianEntry>Divergefrom
mainpublictoqueueingpoint>Free
MealHallwithbathrooms>Discreet
Exitmergingintomainpublic;Entry
fromLobby>Kitchens(for
volunteers)
Usingentiregroundcoverageandentirebuiltuparea
ParkingRequirement(accordingMPD21Delhi)
10%UniversalParking
MarriageHallUsers
ServiceVehicles/FireEngines
Majorly
Vehicular
Vehicular
Universalcrowddressedupand
mostprobablyinhibitedmobility
FreeMealSeekers
Mostly
Pedestrian
MostlyEWSorpeoplevolunteering
service
HighDensityFixed
timings
AdministrativeStaff
Pedestrian/
MetroTravellers
/Car
MiddleClass Fixedtimings
HighDensity
particulartimings
VehicularEntry>DirectAccessto
residential/marriagehalls(fully
coveredpath)
Asperspace
Parking>AdminfloorOrPedestrian
Entry(closetoMetro)>Entry>
AdminFloor
ImportantSpirital
Lecturers/VIPs/Guests
Majorly
Vehicular
VIPStatus LowDensityallday
VehicularEntry>Toeither
residentialormainlobbydropoff
AreaforParking(inSemiBasement) 215openparking(4945sqm)
Page 1 of 4
Architectural Design V Area Programming Report Group V
ClusterType Cluster Privacy Spaces/Description
TentativeFloorsand
Area(sqm)
Floor Cluster2 TotalAreaofFloor(sqm)
Area(sqm) 840 1810
Area(sqm) 960 1810
9490
Area(sqm) 660 2060
14456 Area(sqm) 1460 1620
TotalArea(sqm) 14586
AreaStatementaccordingtoFloors&Clusters
DropOff/Concierge,Queuearea,Services,Freemeal
hall,kitchen,store,washrooms,OAT,eateries,
kitchenforeateries GroundFloor 2650
EntranceLobby,Toilets,CongregationArea,
Sanctum,AncilliaryFacilities
MarriageHall(1),
DiningHall(1),Kitchen,
Toilet 2770 FirstFloor
2720
MeditationCenter,Shops,Toilet
CharitableDispensary,
Toilet
SecondFloor
Offices,StaffRoom,SeminarRoom,Toilet
Suites,4Bedded,
6bedded,Toilet
ThirdFloor 3080
TotalProgrammedArea(sqm)
MainSpiritualCentre 1A Public
Housesthemain
spiritualzonesmain
lobby,sanctum,
congregation,
meditationrooms,free
mealarea
MarriageHall/ResidentialCluster 2 Private
MarriageHallsand
Residences 4FloorsGround,First,
Second,Third
2990
3FloorsGround,First,
Second
Administrative
1976
SplitbetweenFirst,
Second,ThirdFloor
Cluster1
FunctionalClusters
MarriageHall(1),
DiningHall(1),Kitchen,
Toilet
EntireAdministrative
Divisionand
ConferenceHalls
SemiPrivate 1B
Page 2 of 4
Architectural Design V Area Programming Report Group V
Space
Capacity
(people)
Area(sqm) ServiceRequirements TentativeFloor TentativeCluster
Cluster1A Cluster1A
Concierge/DropOff 10 Ground 1
QueueingAreaforFreeMealHall 250 100 Ground 1
Services(DGRoom,ETRoom, ?? Ground 1
EntranceLobby 100 First 1
Toiletsinmainlobby 60 First 1
Shops 100 Second 1
Eateries 100 First 1
Kitchenforeateries 50 Second 1
AncilliaryFacilities(prasadetc) 100 Ground 1
CongregationArea 500 500 First 1
Sanctum 100 First 1
MeditationCentre 500 First 1
Space(MainBuilding)
Capacity
(people)
Area(sqm) ServiceRequirements TentativeFloor TentativeCluster
FreeMealHall 250 300 Ground 1
Kitchenforfreemealhall 100 Ground 1
Storeforfreemealkitchen 100 Ground 1
Toiletsforfreemealhall 80 Ground 1
Circulation 690 40% 1
OpenAirTheatre 200 Ground
PartialAreaA(Cluster1A) 2990
AreaProgramming
MeditationCentre
FreeMealHall
Kitchenforfreemealhall
Space(MainBuilding)
Circulation
OpenAirTheatre
PartialAreaA(Cluster1A)
Storeforfreemealkitchen
Toiletsforfreemealhall
AreaStatement
Toiletsinmainlobby
Space
Concierge/DropOff
QueueingAreaforFreeMealHall
Services
EntranceLobby
Locatedinhighdensityzonewherepeople
linger;Closetoservicelift
Locatedinhighdensityzonewherepeople
linger;Closetoservicelift
Nearcongregationarea&sanctum;Firststop
forpeople
Large,Openandcalm;Acousticinsulationmust
Privatezonevisuallyaccessible;physically
inaccessible
Functions/Requirements
MainLobby
Shops
Shouldbeacousticallyandvisuallyinsulted;
Quickentryandexitfromsite
Entryfromtheparkingalso;spilloverzonefrom
congregationarea;staircasetothe
administrativedepartmentandseminarrooms
30sqmeach6x5:2WC+2B
Locatedinhighdensityzonewherepeople
linger;Closetoservicelift
Eateries
Kitchenforeateries
AncilliaryFacilities(prasadetc)
CongregationArea
Sanctum
Segregated,isolated;AcousticInsulation;Good
viewsandventilation
Open;Acoustically,visuallyisolated;Good
naturalventilation;
Connectedtohall,store,mainhall;Waste
disposaloptions
Closetoserviceroad;LoadingUnloadingBay
30%
Functions/Requirements
Page 3 of 4
Architectural Design V Area Programming Report Group V
Cluster1B Cluster1B
SeminarRoom(6nos.) 50 300 Second 1
Library 700 First 1
Offices(5nos.) 350 ThirdFloor 1
StaffRoom 50 ThirdFloor 1
Toilets(oneachfloorsecond,third) 120 First 1
Circulation 456 30% 1
PartialAreaB(Cluster1) 1976
TotalArea(Cluster1) 4966
Cluster2 Cluster2
Space
Capacity
(people)
Area(sqm) ServiceRequirements TentativeFloor TentativeCluster
MarriageHalls(2nos.) 500+500 2000 ground+first 2
DiningHall(2nos.)+Kitchen 1500 ground+first 2
2Suites 2 120 third
4BedRoom+Toilet(12nos.) 600 third 2
6BedRoom+Toilet(12nos.) 840 third 2
CharitableDispensary/School 2000 second 2
Toilets(oneoneachfloor) 240
Circulation 2190 40% 2
TotalArea(Cluster2) 9490
14456 TotalArea(sqm)
Toilets(oneoneachfloor)
Circulation
TotalArea(Cluster2)
CharitableDispensary/School
TotalArea(Cluster1)
Space
MarriageHalls(2nos.)
Offices(5nos.)
StaffRoom
Toilets(oneachfloorsecond,third)
Circulation
PartialAreaB(Cluster1)
DiningHall(2nos.)+Kitchen
2Suites
4BedRoom+Toilet(12nos.)
6BedRoom+Toilet(12nos.)
SeminarRoom(6nos.)
Library
Withspilloverspaceactsasshadingtolower
floor
Facingseminarroomcommonspilloverspace
Privatezoneindirectentry
AdjacenttoOffices
Functions/Requirements
Onehallopeningintogreenarea;VerticalLink
toresidential
PeripheralLinktoserviceroad
Page 4 of 4

You might also like