Beam_Design_Notes.

doc p1 J WB September 2005


DESIGN OF STEEL BEAMS
[Reading: Allen, H.G. and Bulson, P.S. Background to Buckling, McGraw-Hill, 1980; Trahair, N.S. and
Bradford, M.A. Behaviour and Design of Steel Structures, 2
nd
Ed., Taylor & Francis, 1994; CIVIL 211:
Lecture Notes on Beam Behaviour, Plastic Analysis and Plate Buckling]

INTRODUCTION
The strength limit state requirement for beam design was stated earlier as (see plastic analysis notes)

n
*
M M (1)
where M
*
denotes the maximum bending moment due to the application of factored loads,
is the strength reduction factor (0.9), and
M
n
is the nominal beam moment strength (M
P
or M
RP
)

1.2G+1.5Q
Factored
Loads
Analysis
Design Actions
(bending moments)
(plastic
or
elastic)


However, the assumption that the bending strength of the beam is M
P
is not always justified. Local
or lateral buckling may occur before the full plastic moment capacity of the section is reached,
and prevent it from being reached.

LOCAL BUCKLING AND SECTION MOMENT CAPACITY, M
S

As discussed under plate buckling, parts of a
beam cross-section may buckle locally before the
fully plastic state is reached, or even before yield
stress is reached, depending on their slenderness
ratio. The high stresses in the compression flange
tend to cause buckling as shown in the figure,
limiting the section moment capacity, M
s
.
The effects of local buckling are accounted for in
the same way as used for column sections, using
an effective section property that depends on the
slenderness ratio of the web and flange.

Plate element slenderness ratio,
e
:

250 t
d
or
250 T
b
y
1
y
1
e

= (2)
n
*
M M
b
1
d
1
t
T
Beam_Design_Notes.doc p2 J WB September 2005
Plate element yield and plasticity limits,
ey
and
ep
:

ey
and
ep
are limiting values of slenderness ratio that determine the way a section will fail (for the
origins of
ey
see pages 9 and 10 of Plate Buckling Notes). The values are specified in Table 5.2 of the
Steel Design Standard, NZS3404. Selected values are shown in Table 1 below.

Section slenderness ratio,
s
:

ey
e
e s
largest with element plate of

= (3)


Section description: Hot-rolled
UB, UC
Heavily welded
BOX
Cold-formed
CHS
Cold-formed
RHS
Plate element widths:
b
1
d
1

b
1
b
2
b
1
d
1

d
0

b
2
d
1

ep
9 8
Flange outstand b
1

ey
16 14

ep
30 30
Flange b
2
supported
along both edges

ey
35 40

ep
82 82 45
Web d
1
supported
along both edges

ey
180 130 60

ep
50
Diameter d
0

ey
120
Table 1 Plasticity and yield slenderness limits (selected cases from Table 5.2, NZS3404).



Section moment capacity M
s
and effective section modulus Z
eff



y eff s
Z M = (4)

Beams are divided into three categories depending on how the section slenderness compares with the
plastic and yield slenderness limits, as shown in Table 2.
Beam_Design_Notes.doc p3 J WB September 2005

Slenderness range Behaviour Effective Section Modulus Classification
ep s
<
Section able to reach and
sustain fully plastic moment
M
P
, without local buckling
p eff
Z Z =
COMPACT
ey s ep
< <
Local buckling starts after
yielding, but before fully
plastic moment is achieved.
Moment capacity exceeds
yield moment, M
y
, but is less
than M
P

) Z Z ( Z Z
elastic p
ep ey
s ey
elastic eff



+ =
(intermediate between Z
elastic
and
Z
plastic
)
NON-
COMPACT
ey s
>
Local buckling occurs before
yield stress reached (elastic
failure). Moment capacity
less than yield moment, M
y

s
ey
elastic eff
Z Z

=
alternatively can take Z
eff
as
Z
elastic
of the effective section
(cutting plate widths down to b
eff
)
SLENDER
Table 2 Slenderness criteria and effective section modulus

Examples Effective section modulus and moment capacity
Case 1 Non-compact section
Determine the classification (compact, non-compact or slender) of a grade 300 360UB45.
Also find the effective section modulus and moment capacity.

From section property tables, d
1
/t = 48.2, b
1
/T = 8.46, Z
elastic
=689E3mm
3
, Z
p
= 777E3mm
3
and

y
= 320MPa.
Flange slenderness: ) 16 , 9 cf ( 57 . 9
250
320
46 . 8
250 T
b
ey ep
y
1
fl
= = = =

=
Web slenderness ) 180 , 82 cf ( 53 . 54
250
320
2 . 48
250 T
d
ey ep
y
1
web
= = = =

=
Can see that flange is much more critical than web and so dictates the
Section slenderness: 57 . 9
s
=
Plasticity Limit: 9
ep
=
Yield Limit: 16
ey
=
And since
ey s ep
< < NON-COMPACT section
Effective section modulus:

3 3
elastic p
ep ey
s ey
elastic eff
mm 10 770
) 689 777 (
9 16
57 . 9 16
689
) Z Z ( Z Z
=

+ =



+ =

Section moment capacity kNm 4 . 246 Nm 320 770 Z M
y eff s
= = =
b
1
d
1
t
T
Beam_Design_Notes.doc p4 J WB September 2005
Case 2 Slender section
Determine the classification, effective section modulus and moment capacity of a grade 350
400WC144 (welded column).

From section property tables, d
1
/t = 21.88, b
1
/T = 12, Z
elastic
=2550E3mm
3
, Z
p
= 2830E3mm
3
and

y
= 380MPa.
Flange slenderness: ) 14 , 8 cf ( 8 . 14
250
380
12
250 T
b
ey ep
y
1
fl
= = = =

=
Web slenderness ) 180 , 82 cf ( 97 . 26
250
380
88 . 21
250 T
d
ey ep
y
1
web
= = = =

=
Can see that flange is much more critical than web and so dictates the
Section slenderness: 8 . 14
s
=
Plasticity Limit: 8
ep
=
Yield Limit: 14
ey
=
And since
ey s
> SLENDER section
Effective section modulus:
3 3
s
ey
elastic eff
mm 10 2412
8 . 14
14
2550 Z Z = =

=
Nominal section capacity kNm 916 Nm 380 2412 Z M
y eff s
= = =
NOTE
Most standard, hot-rolled UB and UC sections are proportioned such that they fall into the COMPACT
classification. A small number are NON-COMPACT and none are SLENDER.

LATERAL BUCKLING AND MEMBER MOMENT CAPACITY, M
b

Just as Euler buckling can limit the axial load capacity of a column so lateral
buckling can limit the bending capacity of a beam.
Since lateral buckling involves the entire beam, the associated moment
capacity is referred to as the member moment capacity, M
b
.
Consider a simply supported beam as shown, with the ends restrained against
twist. If a gradually increasing bending moment is applied to the beam it will
initially deflect in a plane perpendicular to the principal axis of bending
(vertically), but will eventually become unstable and
buckle sideways. As buckling proceeds the cross-
section of the beam (at mid-span, for example), will
deflect laterally (out of plane) and also twist as shown.
The phenomenon is referred to as lateral-torsional or
flexural-torsional buckling, and the bending moment at
which buckling commences is known as the elastic
buckling moment M
cr
.

Figure 1 Lateral torsional buckling

Beam_Design_Notes.doc p5 J WB September 2005
It can be shown (see limited derivation on p.7) that a uniform beam subject to a constant bending
moment about its major bending axis will buckle at a critical moment M
cr
, defined by


=
2
w
2
2
y
2
cr
L
EI
GJ
L
EI
M (5)

where EI
y
is the minor axis flexural rigidity
GJ is the torsional rigidity
G is the shear modulus of elasticity
J is the torsion constant (a geometric property of the cross-section shape)
EI
w
is the warping rigidity
I
w
is the warping constant (another geometric property of the cross-section).
The first term


2
y
2
L
EI
, reflects the influence of the beams weak axis bending resistance
The second term


+
2
w
2
L
EI
GJ , accounts for the torsional resistance of the beam.

TORSIONAL RESISTANCE
Torsion is covered in greater depth later in the course. The notes below provide a brief overview of
some aspects that are relevant to the lateral buckling problem

UNIFORM OR ST VENANT TORSION
Illustrated in Fig. 2 is an I-beam, unrestrained against warping, subject to a constant torque T. The
effect is to cause a uniform rate of twist along the length of the member and the system of internal
shear stresses shown. The torque and twist are related by
)
L dz
d
with (
dz
d
GJ T

=

= (6)
J is a relatively simple property of the cross-section shape. For the I-beam cross-
section shown
3 / ) t d BT ( 2 J
3
1
3
+ (7)
Open sections such as I beams are torsionally weak, with a low value of J and
correspondingly high internal shear stresses.
In contrast, closed sections such as RHS and CHS have a high value of J and a closed loop form of
stress distribution. Their torsional resistance is very high.
d
1
t
T
B
Beam_Design_Notes.doc p6 J WB September 2005
o

T
T
Torque, T,
causing twist, o Plan view
Shear stress distribution
in an I-beam due to torsion:
OPEN section -
low torsional resistance
Shear stress distribution
in a box beam due to torsion
CLOSED section -
high torsional resistance

Figure 2 Uniform torsion

WARPING TORSION
Note in the plan view of Figure 2 how the ends of the I-beam displace out of their original plane as the
ends of the flanges rotate about the vertical (y) axis. The longitudinal movement is known as the
warping displacement. Provided warping is allowed to occur unrestrained it has little influence on the
torsional behaviour. However, if one end of the beam above was built in (rigidly fixed e.g. by casting
into concrete) the outcome would be different, as shown in Fig. 3.
warping prevented
Flanges forced to bend,
setting up flexural
and shear stresses
flange shear forces, S ,
generate warping torque
f
T =S x d
w f
S
f
S
f
d
T
w
T (applied torque)

Figure 3 Torsion due to restrained warping
It can be seen in Fig. 3 that twisting the free end of the cantilever results in the flanges bending in a
horizontal plane. The resistance of the flanges to this horizontal bending sets up a system of equal and
opposite bending moments and shear forces acting in each flange. The pairs of equal and opposite
bending moments are known as bi-moments and are a type of internal action (along with normal bending
moments, shear force, etc.). The associated horizontal shear forces, S
f
, create an additional resisting
torque known as the warping torque. For thin-walled open sections, such as I-beams, the warping
torque is likely to be the main contributor to torsional resistance.
It can be shown that the warping torque is given by

3
3
w warp
dz
d
EI T

= (8)
For a section of arbitrary shape the warping constant I
w
is complicated to
calculate. For a doubly symmetric I-beam section such as that shown

4
) T D ( I
I
2
y
w

= (9)
T
B
D x
y
Beam_Design_Notes.doc p7 J WB September 2005
I
w
has units of length
6
, e.g. m
6
or mm
6
. Values of I
w
are included in the tables of section properties
that appear elsewhere in these notes.
Warping torque can still arise even if the beam ends are not restrained from warping. For example the
simply-supported beam of Fig. 1 would develop warping torques if subjected to an external torque at
mid-span (or as the result of twisting associated with lateral buckling).

M
cr
L
M
cr
flange bends in horizontal plane -
warping stresses develop
warping unrestrained
at ends
PLAN VIEW

Figure 4 Non-uniform torsion warping restrained by continuity over central section

DERIVATION OF LATERAL BUCKLING MOMENT
The following brief derivation, for the case of equal applied end moments, is provided for the curious
and can be omitted without prejudice.
M
cr
L
x
y
u
Elevation Section
Plan at end
pins prevent end twist
but allow rotation about
vertical axis (warping)
z
u du
dz
Plan showing longitudinal axis
M
cr
o

Figure 5 Lateral buckling under equal end moments
As with column buckling we seek a deflected and twisted equilibrium position of the beam. The lowest
value of M
cr
at which this is possible determines the required buckling moment.
The governing differential equation for lateral bending equilibrium is
=
cr
2
2
M
dz
u d
EI (10)
The left hand side defines the internal resisting moment and the right hand side is the horizontal
component of the applied moment.
Beam_Design_Notes.doc p8 J WB September 2005
The governing differential equation for torsional equilibrium is

dz
du
M
dz
d
EI
dz
d
GJ
cr
3
3
w
=

(11)
dz
d
GJ

is the internal resistance to uniform torsion and
3
3
w
dz
d
EI

is the internal resistance to warping
torsion. The right hand side defines the disturbing torque due to the applied moment.
When equations (10) and (11) are satisfied at all points along the beam the resulting deflected shape is
one of equilibrium. Such a shape is defined by

L
z
sin
L / EI
M
u
2
y
2
cr

=

= (12)
This buckled shape satisfies the boundary conditions of
zero lateral deflection , 0 ) L ( u ) 0 ( u = = (13)
zero twist at supports , 0 ) L ( ) 0 ( = = (14)
and ends free to warp . 0 ) L (
dz
d
) 0 (
dz
d
2
2
2
2
=

(15)
Eq. (12) also satisfies the equilibrium equations (10) and (11) provided


=
2
w
2
2
y
2
cr
L
EI
GJ
L
EI
M (5)
which defines the critical lateral-torsional buckling moment.


EFFECT OF BENDING MOMENT PATTERN
Equation (5) gives the critical moment for the standard case of uniform bm along the member. This is
the most severe loading case as it results in a constant, maximum compression force in the top flange.
Other loading cases allow the beam to reach higher buckling moments. A few cases are shown in the
table below.

Loading Case (and bms) Critical Moment Comment

M
cr

The standard case.
Value given in equation (5)

1.75M
cr



1.13M
cr



1.35M
cr



1.28M
cr


Beam_Design_Notes.doc p9 J WB September 2005

2.05M
cr


M
M

cr
cr
2
M 5 . 2
M ) 3 . 0 05 . 1 75 . 1 (

+ +

Useful general rule for a beam segment
with linearly varying bm.
1 1

Table 3 Variation of critical moment with bending moment pattern (Table 5.6.1 in NZS3404 lists
more cases see p.19)


EFFECT OF LOAD HEIGHT
The derivation of M
cr
assumes that loading is
applied at the shear centre of the cross-
section (the point at which the resultant
internal shear force acts).
If the load is applied above this point it tends
to de-stabilise equilibrium and reduces the
critical moment. Conversely, applying the load
below the shear centre will increase M
cr
.

CRITICAL FLANGE
For future reference we define the critical flange as the flange which would deflect the furthest
laterally during buckling. Typically it is the compression flange, but in the case of a cantilever is the
tension flange.

MEMBERS, SEGMENTS, SUPPORTS AND RESTRAINTS

MEMBER
segment segment segment
support
twist restraint
at support
restraint to main member provided
by transverse secondary members
(if suitably connected)


1. Members span between supports or between a support and a free end.
2. Supports must provide FULL or PARTIAL restraint to a cross section (see definitions below).
3. Members are usually restrained at discrete points between their supports.
4. The effect of the restraints is to divide the member into segments. Member moment capacity is
then determined on a segment by segment basis.
5. The member moment capacity needs to be determined only for x-axis bending. For y-axis
bending, only the section moment capacity is required (a beam cannot buckle laterally when bent
about its minor axis).
6. Restraints provide full, partial or lateral restraint to a cross section, depending on the nature of
the restraint and the location of the critical flange.
Load applied at shear centre
No change in M
cr
Load applied at top flange
Destabilising effect
M reduced
cr
load
beamresistance acts
through shear centre
load
beams resisting force
in line with load
Beam_Design_Notes.doc p10 J WB September 2005
LATERAL AND TORSIONAL RESTRAINTS
The nature and positioning of the restraints on a beam are of profound importance. The otherwise
poor performance of an unrestrained beam can be greatly improved by the provision of restraints.
Restraint of some sort is always provided at the supports of a beam, but frequently at other,
intermediate points along its length as well.
Restraints are classified as FULL, PARTIAL or LATERAL according to how well they restrain the
critical flange against lateral movement, and the whole cross-section against twisting.
A support must always provide FULL or PARTIAL restraint.

Type Description Examples (C denotes critical flange)
FULL (F)
Critical flange restrained against
lateral deflection and twist fully
restrained
web
stiffener
C C

(Either flange could be critical)
PARTIAL (P)
Some point other than critical
flange restrained against lateral
deflection and twist partially
restrained, or
full twist restraint with partial or
no lateral deflection restraint
flexible
fly brace
C
C

LATERAL (L)
Critical flange restrained against
lateral deflection
C

UNRESTRAINED
(U)
No constraint to the critical
flange
C


ROTATIONAL RESTRAINT IN PLAN (WARPING RESTRAINT)
Figures 2 to 5 show warping rotations of the flanges about the minor y axis at beam ends. If these
minor axis warping rotations are restrained by a support, or other means, restraining moments and
shears develop adding significantly to the beams torsional resistance, raising its critical lateral
buckling moment. Fig. 6 shows four types of restraining moment that may be present at the ends of a
beam.
M
x
Major axis bending moment which provides restraint about the major axis (e.g. at the fixed end
of a cantilever). M
x
is determined by normal structural analysis (plastic or elastic) and depends
on the applied load, beam span, etc.
T Torque about the longitudinal z axis providing restraint against end twisting.
M
top
Top flange end moment providing restraint about the minor axis and against end warping.
M
bot
Bottom flange end moment providing restraint about the minor axis and against end warping.
Rotational restraint about the y axis may for example, be provided by a continuation of the member
under consideration see Fig. 7
Beam_Design_Notes.doc p11 J WB September 2005
z
x
y
M
x
M
top
M
bot
T


Figure 6 Types of restraining moment at a support

ELEVATION
PLAN VIEW
Effective length, L
e
restrained segment
lateral rotation
restrained by
adjacent segment
adjacent segment needs full lateral
restraint (or of shorter span)


Figure 7 Example of lateral rotation (warping) restraint provided by adjacent segments.

EFFECT OF IMPERFECTIONS
1.0
0
0.5
Full plasticity, M
P
Elastic buckling, M
cr
NZS3404 Eq.5.6.1.1(3)
D
i
m
e
n
s
i
o
n
l
e
s
s

m
o
m
e
n
t

c
a
p
a
c
i
t
y
,

M
/
M

b

P
Slenderness ratio, L/r
y
100 200 300

Figure 8 Moment capacity of imperfect beams
The inevitable presence of initial imperfections, such as residual stress and lack of straightness, will
influence the moment capacity of a beam just as they influenced the axial load capacity of a column.
Short, stocky beams will reach a moment capacity of M
P
and long slender beams will fail by lateral
buckling at a moment close to the theoretical M
cr
. In between these extremes failure will involve a
Beam_Design_Notes.doc p12 J WB September 2005
combination of inelastic material behaviour (yielding) and lateral buckling. Fig. 8 shows measured
failure moments for I-beams compared with the M
P
and M
cr
limits.
It can be seen from Fig. 8 that the empirical beam design curve specified in NZS3404 provides a
transition between the full plasticity and elastic buckling curves that is close to the lower bound of
the experimental results shown. The equation of the beam design curve is

s
cr
s
2
cr
s
b
M
M
M
3
M
M
6 . 0 M

= (16)
or
s s b
M M =
where

=
cr
s
2
cr
s
s
M
M
3
M
M
6 . 0 (17)
is the slenderness reduction factor,
M
s
is the section moment capacity defined earlier, and
M
cr
is the lateral buckling moment for a beam of effective length, L
e
.


=
2
e
w
2
2
e
y
2
cr
L
EI
GJ
L
EI
M (18)
(which is the same as equation (5) apart from L being replaced by L
e
, the effective length.)

STRENGTH LIMIT STATE DESIGN TO NZS3404
Beam strength must be checked for each segment of a beam (see p.9 for segment definition). The
segment requiring the greatest strength dictates the required section size.
If M
*
denotes the design bending moment in a beam determined by analysis using the factored loads,
then the beam must satisfy

s
*
M M
and
b
*
M M
where is the strength reduction factor (0.9),
M
s
is the nominal section capacity in bending,
and M
b
is the nominal member capacity in bending

SECTION MOMENT CAPACITY
Depends on plate slenderness limits. Defined earlier as


y eff s
Z M = (4)

MEMBER MOMENT CAPACITY
Depends on cross-section properties, bending moment pattern, degree of restraint and load height:


s s m b
M M = (19)

where
m
is a moment modification factor that takes account of bending moment pattern
and
s
is the slenderness reduction factor defined in Eq. (17).
Beam_Design_Notes.doc p13 J WB September 2005
Moment modification factor,
m

For each segment of a beam,
m
can be determined from NZS3404s Table 5.6.1 (reproduced on p.19)
which lists a range of common bending moment patterns.
For bending moment distributions which are not represented in Table 5.6.1 the following general rule
can be used:

( ) ( ) ( )
5 . 2
M M M
M 7 . 1
2
*
4
2
*
3
2
*
2
*
max
m

+ +
= (20)
where sign in positive as taken segment, the in moment bending design maximum M
*
max
=
segment the of points quarter the at moments bending design M , M
*
4
*
2
=
segment the of point - mid the at moment bending design M
*
3
=
EXAMPLES
1. Consider the right hand span, BC, of the
continuous beam shown. The secondary beams
apply loads and also provide restraint, hence we
must consider the three segments shown.
Segment 1
72
-92

Use Case 1 from Table 5.6.1 (also shown as last row
of Table 3 on p.8).
M = 92,
m
M = 72. (Choose M as the larger of the end moments)
Hence
m
= 72/92 = 0.783, and
5 . 2 75 . 2 ) 783 . 0 ( 3 . 0 ) 783 . 0 ( 05 . 1 75 . 1 3 . 0 05 . 1 75 . 1
2 2
m m m
= + + = + + =

m
= 2.5 (maximum value for this case)
Segment 2
72
116

Using Case 1 again:
M=116,
m
M = -72, and
m
= -72/116 = -0.62.
) 5 . 2 ( 21 . 1 ) 62 . 0 ( 3 . 0 ) 62 . 0 ( 05 . 1 75 . 1 3 . 0 05 . 1 75 . 1
2 2
m m m
= + + = + + =

m
= 1.21
Segment 3 (also segment AB)
116

Use Case 9 from Table 5.6.1 (also appears as row 2 of Table 3 on p.8)

m
= 1.75.
Could also have used Case 1 from Table 5.6.1, with M=116,
m
M=0, and
m
=0 giving
) 5 . 2 ( 75 . 1 ) 0 . 0 ( 3 . 0 ) 0 . 0 ( 05 . 1 75 . 1 3 . 0 05 . 1 75 . 1
2 2
m m m
= + + = + + =
3m 2m 2m 2m
60kN 80kN
segment 1 segment 2 segment 3
-92
72
116
restraint restraint
A B C
Beam_Design_Notes.doc p14 J WB September 2005
2. Consider the right hand span, BC, of the
continuous beam shown. The secondary beams in
this case are assumed to provide no lateral
restraint and so BC must be treated as a single
segment.
Segment 1
Same bending moment pattern as segments 1 and 3
in previous example hence the same

m
= 1.75
Segment 2
M
*
=109
max
M
*
=38
2
M
*
=105
3
M
*
=93
4
Since there is no matching bm pattern in Table 5.6.1 we resort to the general rule (20)
( ) ( ) ( )
5 . 2 275 . 1
93 105 38
) 109 ( 7 . 1
M M M
M 7 . 1
2 2 2 2
*
4
2
*
3
2
*
2
*
max
m
=
+ +
=
+ +
=
*
max
M is the (positive) value of the absolute maximum moment anywhere in the segment i.e. the
109kNm moment at end B in this case.
The quarter point and mid-span moments can be read directly from the bending moment diagram.

Slenderness reduction factor,
s

s
can be calculated from Equations (17) and (18):

=
cr
s
2
cr
s
s
M
M
3
M
M
6 . 0 (17)


=
2
e
w
2
2
e
y
2
cr
L
EI
GJ
L
EI
M (18)
M
s
, the section moment capacity and L
e
, the effective length, are needed first. However, the
calculation is tedious and it is usual to look up pre-calculated values of
s
in tables.
Table A1 sets out values of
s
for grade 300 UB sections with effective lengths ranging up to 10m.
Table A2 covers grade 300 UC sections.
Table A3 lists grade 300 PFC (Parallel Flange Channel) sections with effective lengths up to 7m.
Similar tables are available for most grades of standard steel sections.


Effective Length, L
e

The effective length concept is used in the same way and for the same reasons as in the case of
column buckling. A single buckling moment equation can then be used, with different support
conditions, etc, accommodated by altering the effective length.
3m 2m
-109
no restraint
at loads
A B C
2m 2m 2m
40kN 40kN 40kN
38
105
93
segment 2 segment 1
Beam_Design_Notes.doc p15 J WB September 2005
Effective length will depend on lateral-torsional (twist) restraint, y-axis rotational restraint (warping)
and load height relative to the shear centre.
L k k k L
r L t e
= (21)
where k
t
= a twist restraint factor given in Table 5.6.3(1),
k
L
= a load height factor given in Table 5.6.3(2),
k
r
= a rotation restraint factor, typically = 1.0, otherwise as given in Tables 5.6.3(3).

In Tables 5.6.3(1), 5.6.3(2) and 5.6.3(3)
d = overall depth of section
L = segment length
n
w
= number of webs (e.g. 1 for I-beam, 2 for single-cell box)
t
f
= thickness of critical flange
t
w
= thickness of web
F = fully restrained
L = laterally restrained
P = partially restrained
U = unrestrained
and two of the symbols F, L, P, U are used to indicate the restraint conditions at the two ends,
e.g. FF.

Note For loads applied to a member along a principal (y) axis passing through the shear centre and
the centroid (such as an I-beam), the classification of load height applied through the top
flange need be applied only when the load itself or the structural system transferring the load
to the segment is laterally unrestrained.
Beam_Design_Notes.doc p16 J WB September 2005


Note
Restraint of minor axis rotation requires a support of significant stiffness. Typically this is not
available and the factor is left as k
r
= 1. NZS3404 states the following conditions:
1. k
r
shall only be taken as less than unity when effective rotational restraints act at one or both ends
of a segment which is restrained (torsionally) at both ends. k
r
shall be taken as unity for all
segments which are unrestrained at one end.
2. A rotational restraint at a cross section which is fully, partially or laterally restrained may be
considered to provide restraint against lateral rotation of the critical flange about the minor y-
axis, providing that its flexural stiffness in the plane of rotation is comparable with the
corresponding stiffness of the restrained member, EI
y
.
3. A segment which has full lateral restraint may be deemed to provide rotational restraint to an
adjacent segment which is part of the same member (.e. the member containing both segments is
continuous through the point of restraint). See Fig.7.
4. A segment which does not have full lateral restraint shall be assumed to be unable to provide
rotational restraint to an adjacent segment which is part of the same member.



Beam_Design_Notes.doc p17 J WB September 2005
DESIGN CAPACITY CHECK strength limit state
The following steps can be used as an approximate guide to the sequence of operations needed to
check the design of a beam for flexure. Note that some details have been omitted for simplicity and
the procedure should not be used for practical design purposes.
FOR EACH LOAD CASE (1.2G+1.5Q, 0.9G+W, etc)
1. Apply strength limit state factored loads (e.g. 1.2G+1.5Q) and analyse (plastic or elastic) to obtain
bending moment diagram.
2. Determine support restraints plus any restraints acting on the beam between supports. Subdivide
the beam into segments accordingly.
3. Determine section moment capacity,
y e sx
Z M = , by comparing the plate element slenderness
ratios with the limits to obtain the effective section modulus, Z
e
see p.2.
Alternatively, for standard UB and UC sections, the value can simply be looked up in Table A1 or
A2 (p.20).
FOR EACH SEGMENT:
4. Determine the moment modification factor
m
using Table 5.6.1 or Eq. (20).
5. Determine k
t
, k
L
, and k
r
(twist, load height and warping rotation restraint factors) and hence
obtain the effective length, L k k k L
r L t e
= , (Eq. 21)
- refer to Tables 5.6.3(1), 5.6.3(2) and 5.6.3(3).
6. Determine the slenderness reduction factor,
s
, using Eqs. (17) and (18).
Alternatively, for standard sections, the value can be looked up in Table A1 or A2.
7. Reliable member moment capacity,
sx s m bx
M M =
8. Check
bx
*
x
M M , where
*
x
M is the design (maximum) major axis bending moment in the segment.

9. Ensure step 8 is satisfied for all segments and all load cases.


EXAMPLE 1
A 250UB31 Grade 300 beam is simply supported over a
span of 4.8m. Uniformly distributed live load together
with self weight gives a total w=1.2G+1.5Q=12kN/m.
Loading is applied to the top flange but does not provide
any restraint.
The end supports provide full lateral restraint of both
flanges.
Design Check
1. From BM diagram kNm 6 . 34 M
*
x
= .
2. Restraints at ends only beam consists of a single, full length segment (4.8m long).
3. Section moment capacity kNm 8 . 113 000 , 320 10 395 9 . 0 Z M
6
y e sx
= = =


(or 114 kNm direct from Table A1..the easiest route!)
4.8m
1.2G+1.5Q=12kN/m
M*=34.6kNm
bending moment
250 UB 31
Beam_Design_Notes.doc p18 J WB September 2005
4. Moment modification factor, 13 . 1
m
= (Table 5.6.1, case 6 or 7, with 0
m
= )
5. k
t
= 1.0 (FF in Table 5.6.3.1)
k
L
= 1.4 (FF in Table 5.6.3.2, load within segment)
k
r
= 1.0 (FF, but no minor axis rotation restraint Table 5.6.3.1)
m 72 . 6 8 . 4 0 . 1 4 . 1 0 . 1 L k k k L
r L t e
= = =
6. Slenderness reduction factor, 295 . 0
0 . 6 0 . 7
0 . 6 72 . 6
) 281 . 0 333 . 0 ( 333 . 0
s
=

= (Table A1).
In Table A1: L
e
= 6m:
s
= 0.333
L
e
= 7m:
s
= 0.281
(result obtained by interpolation see alternative direct calculation below*)
7. kNM 0 . 38 114 295 . 0 13 . 1 M M
sx s m bx
= = =
8. Check:
bx
*
x
M M
OK 0 . 38 6 . 34
9. Try a smaller size, 250 UB 25:

kNm 92 M
sx
=


m
= 1.13 (no change)
L
e
= 6.72m (no change)

s
= 0.238 (interpolation, Table A1)
kNM 7 . 24 92 238 . 0 13 . 1 M M
sx s m bx
= = =

bx
*
x
M M
NG 7 . 24 6 . 34
Smaller size inadequate USE 250 UB 31


* Direct calculation of
s

Properties needed for calculation:
E kPa 10 200
6
(material property)
G kPa 10 80
6
(material property)

y
kPa 10 320
3
(from Table of UB section properties)
I
y

4 6
m 10 47 . 4

(from Table of UB section properties)
I
w

6 9
m 10 9 . 65

(from Table of UB section properties)
J
4 9
m 10 3 . 89

(from Table of UB section properties)
Z
elastic

3 6
m 10 354

(from Table of UB section properties)
Z
p

3 6
m 10 397

(from Table of UB section properties)
Z
e

4 6
m 10 395

(from Table of UB section properties, or by using

3 6
elastic p
ep ey
s ey
elastic e ey ep s
m 10 395 ) Z Z ( Z Z , 16 , 9 , 2 . 9

=


+ = = = =
L
e
6.72m
M
sx
kNm 4 . 126 10 320 10 395 Z
3 6
y e
= =


kNm 3 . 44
L
EI
GJ
L
EI
M
2
e
w
2
2
e
y
2
cr
=


= (Eq. 18)
290 . 0
M
M
3
M
M
6 . 0
cr
s
2
cr
s
s
=

= (c.f. 0.295 from Table A1)



Beam_Design_Notes.doc p19 J WB September 2005

Beam_Design_Notes.doc p20 J WB September 2005



Beam_Design_Notes.doc p21 J WB September 2005
EXAMPLE 2
Member:
250UB31 Gr 300 beam, simply supported over a span of 6.0m.
Loading:
Factored loading amounts to 12kN/m applied to the top flange
plus a moment of 40 kNm at the left-hand end. The load is not
laterally restrained.

Restraints:
LEFT: Both flanges fully restrained laterally, and against
minor axis rotation (warping restraint).
RIGHT: Bottom flange restrained against rotation and lateral displacement, top flange unrestrained.
DESIGN CHECK
1. Design moment:
From BM diagram kNm 0 . 40 M
*
x
= .
2. Segments:
Restraints at ends only beam consists of a single, full length segment (6.0 m long).
3. Section moment capacity kNm 114 M
sx
= (Table A1)
4. Moment modification factor,
m
:
Table 5.6.1, case 6: 74 . 0
8 / 6 12
40
8 / wL
40
2 2 m
=

= =

34 . 1 5 . 3 25 . 1
m m
= + =
5. Effective length:
Segment has Full restraint at one end, Partial at the other
End restraint = FP
k
t
= 015 . 1
1
1
1 . 6 2
6 . 8
6000
252
1
n
1
t 2
t
L
d
1
3
w
3
w
f
=

+ =

+ (FP in Table 5.6.3.1)


k
L
= 1.4 (Table 5.6.3.2: FP, load within segment, Top Flange)
k
r
= 1.0 (FP, but no minor axis rotation restraint Table 5.6.3.1)
m 25 . 7 0 . 6 85 . 0 4 . 1 015 . 1 L k k k L
r L t e
= = =
6. Slenderness reduction factor,
s

In Table A1: L
e
= 7m:
s
= 0.281
L
e
= 8m:
s
= 0.243
L
e
= 7.25m:
s
= 0.272 (linear interpolation)
7. Member capacity
kNM 5 . 41 114 272 . 0 34 . 1 M M
sx s m bx
= = =
8. Check:
bx
*
x
M M
OK 5 . 41 0 . 40
6.0m
w =12kN/m
250 UB 31
40kNm
40 kNm
Beam_Design_Notes.doc p22 J WB September 2005
44.1
(e)
177.9
EXAMPLE 3
4m
A B C
2.5m 2.5m 4m
D
2.5m 2.5m
160kN

The continuous beam ABCD is to be designed to carry load-factored midspan live loads of 1.5Q=160kN
that may act on any or all spans. The task is to select a suitable grade 300 UB section and suggest
appropriate lateral restraint locations.
Restraints:
All supports are assumed to provide full torsional restraint. Loads provide no restraint and are applied
to the top flange.
Analysis:
We will ignore self-weight and hope to show that its
effect is negligible. This leaves 5 load cases to consider,
as shown.
The results could be obtained from just two analyses (by
moment distribution, for example):
(a) Load on AB
(b) Load on BC
All other cases can be obtained as combinations of (a) and
(b). For example case (c) is simply (a)+(b), and case (d) is
(a)+(b)+mirror image of (a).
Maximum design moment (all cases) = 207.1kNm.

First approximation:
Assume a compact section, and take Z
e
= Z
p
.
For
y e
*
Z M <
Require
3 3 3 6
p
mm 10 767 m 10 767
000 , 300 9 . 0
1 . 207
Z = =

>


Try 360UB44.7, Z
p
=777x10
3
mm
3
(isnt quite compact, but has only slightly smaller Z
e
=770 x10
3
mm
3
,
more than compensated for by
y
=320MPa, so that kNm 222 Z
y e
= , > 207.1)
Check end spans AB, CD
Top flange
Maximum M
*
(+ve)=178kNm - load case (e) - top flange critical (comprn).
FF segment, 5m long. k
t
=1, k
L
=1.4, k
r
=1, L
e
= 1.4*5 = 7.0m

s
= 0.293 (Table A1)
294 . 0
5 160 3
16 1 . 44
m
=


= (Table 5.6.1, case 4)
39 . 1 29 . 0 15 . 0 35 . 1
m
= + =
NG ) kNm 178 ( M kNm 4 . 90 222 293 . 0 39 . 1 M
*
max b
< = =
Try lateral (L) restraint to top flange, mid-span
168.1
63.7
19.6
112.9
207.1
112.9
111.7
176.7
185.0
93.3
121.5
157.1
162.9
157.1
121.5
177.9
44.1
177.9
44.1
(a)
(b)
(c)
(d)
(e)
A B
5m
160kN
F F
Beam_Design_Notes.doc p23 J WB September 2005
This creates two segments, 2.5m long. Considering the left hand segment:
FL segment, 2.5m long. k
t
=1, k
L
=1 (load outside seg), k
r
=1, L
e
= 1.0*2.5 = 2.5m

s
= 0.778 (Table A1).

m
= 1.75 (Table 5.6.1, case 1,
m
= 0, or case 9).
kNm 302 222 778 . 0 75 . 1 M
b
= = ,
However OK ) kNm 178 ( M kNm 222 M be must M
*
max s b
> =
Right segment certain to be less critical as bending moment pattern will give rise
to a higher
m
:
25 . 0
178
1 . 44
m
= = (Table 5.6.1, case 1).
(max) 5 . 2 78 . 3 ) 25 (. 3 . 0 ) 25 . 0 ( 05 . 1 75 . 1
2
m
= = + + = .
OK kNm 222 M still M so , 1
s b s m
= = >
Bottom flange
Top flange restraint does not restrain bottom flange. For loading case
(b) bottom flange is critical so spans AB and BC revert to 5m segments.
Maximum M*(-ve)=113kNm
FF segment, 5m long. k
t
=1, k
L
=1, k
r
=1, L
e
= 5.0m

s
= 0.436 (Table A1)

m
= 1.75 (Table 5.6.1, case 1,
m
= 0).
OK ) kNm 113 ( M kNm 169 222 436 . 0 75 . 1 M
*
max b
> = =
Check middle span, BC
Top flange
Top flange is critical flange for load cases (b), (c) and (d).
Maximum M
*
(+ve)=207kNm - load case (b) - top flange critical.
FF segment, 8m long. k
t
=1, k
L
=1.4, k
r
=1, L
e
= 1.4*8 = 11.2m

s
< 0.190 (Table A1;
s
= 0.19 is for L
e
=10m)
706 . 0
8 160
8 113
; 113
8
FL
m m
=

= = (Table 5.6.1, case 4)


60 . 1 706 . 0 36 . 0 35 . 1
m
= + =
NG ) kNm 207 ( M kNm 5 . 67 222 19 . 0 6 . 1 M
*
max b
< = =
Try lateral (L) restraint to top flange, mid-span
This creates two segments, 4m long. Considering the left hand segment:
FL segment, 4m long. k
t
=1, k
L
=1 (load outside seg), k
r
=1, L
e
= 1.0*4 = 4m

s
= 0.55 (Table A1).
546 . 0
207
113
m
= = (Table 5.6.1, case 1).
42 . 2 ) 55 (. 3 . 0 ) 55 . 0 ( 05 . 1 75 . 1
2
m
= + + = .
OK ) kNm 207 ( M kNm 222 M M so , 33 . 1
*
max s b s m
> = = =
177.9
F L
A
2.5m
177.9
44.1
F
L
B
5m
113
(b)
F
F
113
207
113
FF FF
B C
207
F
L
B
4m
113
Beam_Design_Notes.doc p24 J WB September 2005
Bottom flange
Predominantly ve bm in loading cases (e) and (a) results in critical bottom flange. Since bottom flange
is unrestrained it becomes an 8m segment.
Load case (e):
Maximum M*(-ve)=44 kNm
FF segment, 8m long. k
t
=1, k
L
=1, k
r
=1, L
e
= 8.0m

s
= 0.248 (Table A1)

m
= 1.0 (Table 5.6.1, case 8)
OK ) kNm 44 ( M kNm 55 222 248 . 0 0 . 1 M
*
max b
> = =
Load case (a):
Maximum M*(-ve)=64 kNm
FF segment, 8m long. k
t
=1, k
L
=1, k
r
=1, L
e
= 8.0m

s
= 0.248 (Table A1)
31 . 0
7 . 63
6 . 19
m
= = (Table 5.6.1, case 1).
1 . 2 ) 31 (. 3 . 0 ) 31 . 0 ( 05 . 1 75 . 1
2
m
= + + =
OK ) kNm 64 ( M kNm 115 222 248 . 0 1 . 2 M
*
max b
> = =
Check that dead load IS negligible:
Dead load is 44.7 kg/m giving m / kN 53 . 0 45 . 0 2 . 1 w
dead
= = . Applying a uniform spread load of
0.53kN/m gives the bms shown below.
2.47
1.75
0.64
2.47
0.64

These are insignificant compared with the 1.6Q (live load) bms which ranged up to 207 kNm.

Final configuration:

4m
A B C
2.5m 2.5m 4m
D
2.5m 2.5m
F F F F L L L
=additional restraint to top flange
C
360 UB 45