You are on page 1of 13

Anchoring Systems

4.3.3

Kwik Bolt II Expansion Anchor (KB II)

4.3.3.1 Product Description

Nut

Washer

Collar

Wedge Dimple

The Kwik Bolt II is a stud type expansion anchor with a single piece wedge
that performs as three independent wedges if necessary to provide consistent
performance in a wide variety of medium-duty applications. Applicable base
materials include concrete, lightweight concrete and grout filled block.

Impact Section
(Dog Point)

Anchor Body

Wedges

Expansion Cone

Product Features

Impact section (Dog Point) prevents thread damage during installation


Independent 3-piece wedge with dimples help prevent anchor from
spinning during installation
Length identification code facilitates quality control & inspection
after installation
Anchor size is same as drill bit size for easy installation
Comprehensive performance testing to provide high & consistent
performance in concrete, lightweight concrete & grout filled block
base materials

Mechanical expansion allows immediate load application


Can be installed in bottomless hole, which allows the anchor to be
driven flush with the surface after use. Eliminates cutting bolt heads.
Can be installed through the fixture, improving productivity
Comprehensive product offering includes many head styles, sizes,
carbon steel and stainless steel materials for a variety of applications

Guide Specifications
Anchor:

Expansion anchor shall be wedge type with a single piece three section wedge and zinc plated in accordance with ASTM B633.
Anchors must meet the description of Federal Specification A-A 1923A, Type 4. Anchor will bear a length identification code that is
visible after installation. Anchors shall be Kwik Bolt II as manufactured by Hilti, Inc., Tulsa, OK.

Installation:

Drill hole with a Hilti carbide tipped TE Bit or matched tolerance diamond core bit. Remove dust from the hole with oil free compressed
air. Drive anchor into the hole so that at least six threads are below the top of the fixture. Tighten to the recommended installation torque.

Listings/Approvals

Underwriters Laboratory No. 203 Pipe Hangers (3/8"-3/4" diameters)


International Conference of Building Officials (ICBO ES): Evaluation Report No. 4627, KB II
International Conference of Building Officials (ICBO ES): Evaluation Report No. 5224, HCKB
Southern Building Code Congress (SBCCI): Report No. 9930
City of Los Angeles (COLA): Research Report No. 25226
Factory Mutual (FM) KB II 3/8" x 2 1/4" w/Rod Coupler
Metro-Dade County Approval # 01-1003.03

4.3.3.2 Material Specifications


Carbon Steel KB II studs conform to ASTM A510 with chemical composition of AISI 1038 except
all countersunk KB II and KB 3/4" x 12", KB II 1" x 6", KB II 1" x 9" and KB II 1" x 12" which conform to
ASTM A108 with chemical composition of AISI 11L41
Wedges are manufactured from AISI 1010 carbon steel, except KB II 3/4" x 12", KB II 1" x 6",
KB II 1" x 9" and KB II 1" x 12" wedges which conform to chemical composition of AISI 304
Nuts are carbon steel conforming to ASTM A563 Grade A and meet dimensional requirements
of ANSI B18.2.2
Washers are carbon steel conforming to SAE 1005-1033 and meet dimensional requirements
of ANSI 18.22.1 Type A Plain
All carbon steel parts are zinc plated in accordance with ASTM B633, Type III Fe/Zn 5
Stainless Steel KB II studs conform to ASTM A276 or ASTM A493 with chemical composition of
either AISI 304 or 316 1/4" thru 9/16"
over 9/16"
Stainless steel wedges are of equivalent grade as bolts.
Nuts are stainless steel conforming to ASTM F594 with chemical composition of either AISI 304 or 316
and meeting dimensional requirements of ANSI B18.2.2 to conform with stud material
Washers are AISI 304 or 316 stainless steel conforming to ASTM A240 to conform with stud material
Note: Special Order Kwik Bolt II, nuts and washers may vary from standard materials.

154

MECHANICAL PROPERTIES
fy
min. fu
ksi (MPa)
ksi (MPa)
41 (282)
75 (517)

75 (517)
90 (620)

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

76 (524)
64 (441)

90 (620)
76 (524)

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

Anchoring Systems

Kwik Bolt II Expansion Anchor

4.3.3

4.3.3.3 Technical Data


Kwik Bolt II Specification Table
Bolt Size
Details
dbit: nominal bit diameter1

/4

/8

in.
(mm)

/4

/8

1
(25.4)

(15.9)

(12.7)

/8

/2

/4

(19.1)

(9.5)

in.

/8

/2

(6.4)

/4

hmin / hnom: minimum/standard


depth of embedment

in.
(mm)

11/8
(29)

2
(51)

15/8
(41)

21/2
(64)

21/4
(57)

31/2
(89)

23/4
(70)

4
(102)

31/4
(83)

43/4
(121)

41/2
(114)

6
(152)

h1: minimum/standard
hole depth

in.
(mm)

13/8
(35)

21/4
(57)

2
(51)

27/8
(73)

23/4
(70)

4
(102)

33/8
(86)

45/8
(118)

4
(102)

51/2
(140)

51/2
(140)

7
(178)

: anchor length min./max.


other length available

in.
(mm)

13/4
(44)

41/2
(114)

21/4
(57)

7
(178)

23/4
(70)

7
(178)

33/4
(95)

10
(254)

41/4
(108)

12
(305)

6
(152)

12
(305)

th: thread length/


extra thread length

in.
(mm)
in.
(mm)

/8 / 11/8
4
(22/28) (102)

11/4
(32)

11/2
(38)

31/2 / 41/2
(89/114)

11/2
(38)

31/2 / 5
(89/127)

21/4
(57)

41/2
(114)

dh: wedge clearance


hole in plate
Tinst:
Recommended
Installation
Torque 2
Guide
Values
ft lb
(Nm)

Stainless hmin
Steel
hnom
Carbon hmin
Steel
hnom
Lightweight Carbon hmin
Concrete
Steel
hnom
Grout
Carbon hmin
Filled Block
Steel
hnom
Normal
weight
Concrete

/4
(19)

3
(76)
5

/16
(7.9)
4
7
4
7
4
4
4
4

(5.4)
(9.5)
(5.4)
(9.5)
(5.4)
(5.4)
(5.4)
(5.4)

h: min. base material thickness

/16
(11.1)
20
30
20
25
15
20
15
20

(27.0)
(40.5)
(27.0)
(33.8)
(20.3)
(27.0)
(20.3)
(27.0)

/4
(76)
9

/16
(14.3)
40
75
40
65
25
30
25
30

(54.1)
( 101)
(54.1)
(87.8)
(33.8)
(40.5)
(33.8)
(40.5)

11

/16
(17.5)
85
110
85
110
65
75
65
75

( 115)
( 149)
( 115)
( 149)
(87.8)
( 101)
(87.8)
( 101)

13

/16
(20.6)
150
200
150
235
135
150
120
130

(203)
(270)
(203)
(318)
(182)
(203)
(162)
(176)

11/8
(28.6)
235
450
250
450

(318)
(608)
(338)
(608)

3" (76 mm) or 1.3 hef , whichever number is greater

1. Hilti matched tolerance carbide-tipped drill bit (see section 7.4.1) or matched tolerance HILTI DD-B or DD-C diamond core bits (available in diameters from 1/2" to 1").
2. Do not apply any type of lubricant to threads prior to torquing anchor.

Combined Shear and Tension Loading


Nd

5/3

(N )
rec

Vd

5/3

(V )

1.0 (Ref. Section 4.1.2.7)

rec

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

155

Anchoring Systems

4.3.3

Kwik Bolt II Expansion Anchor

Carbon Steel Kwik Bolt II Allowable Loads in Concrete


Anchor
Diameter
in. (mm)

/4

(6.4)

/8

(9.5)

/2

(12.7)

/8

(15.9)

/4

(19.1)

6000 psi (41.4 MPa)

Tension
lb (kN)

Shear
lb (kN)

Tension
lb (kN)

Shear
lb (kN)

Tension
lb (kN)

Shear
lb (kN)

11/8
(29)

270
(1.2)

430
(1.9)

330
(1.5)

430
(1.9)

380
(1.7)

430
(1.9)

470
(2.1)

430
(1.9)

22
(51)

560
(2.5)

3 /4
(95)

670
(3.0)

530
(2.4)

670
(3.0)

530
(2.4)

15/8
(41)

530
(2.4)

1100
(4.9)

850
(3.8)

1100
(4.9)

21/2 1
(64)

1200
(5.3)

41/4 1
(108)

1330
(5.9)

1470
(6.5)

1550
(6.9)

1470
(6.5)

21/4
(57)

1170
(5.2)

1970
(8.8)

1730
(7.7)

1970
(8.8)

31/2 2
(89)

1870
(8.3)

2450
(10.9)

2800
(12.5)

2450
(10.9)

3070
(13.7)

2670
(11.9)

3070
(13.7)

3840
(17.1)

4190
(18.6)

3840
(17.1)

4140
(18.4)

3200
(14.2)

4140
(18.4)

6
(152)

2080
(9.3)

2 3/4
(70)

1600
(7.1)

42
(102)

2400
(10.7)

72
(178)

3200
(14.2)

31/4
(83)

1970
(8.8)

43/4 2
(121)

2930
(13.0)

(25.4)

4000 psi (27.6 MPa)

Shear
lb (kN)

3000 psi (20.7 MPa)

Tension
lb (kN)

2000 psi (13.8 MPa)

Embedment
Depth
in. (mm)

8
(203)

4000
(17.8)

41/2
(114)

3330
(14.8)

6
(152)

4930
(21.9)

9
(229)

6670
(29.7)

530
(2.4)
990
(4.4)
1470
(6.5)
1940
(8.6)
2450
(10.9)
3070
(13.7)
3840
(17.1)
4140
(18.4)
5120
(22.8)
7070
(31.4)
9200
(40.9)

1. Values shown are for a shear plane acting through the anchor bolt
body. When the shear plane is acting through the anchor bolt threads,
reduce the shear values by 15%.

590
(2.6)
670
(3.0)
650
(2.9)
1290
(5.7)
1390
(6.2)
1310
(5.8)
2130
(9.5)
2310
(10.3)
1870
(8.3)
2850
(12.7)
3470
(15.4)
2320
(10.3)
4130
(18.4)
4930
(21.9)
4050
(18.0)
6000
(26.7)
7670
( 34.1)

530
(2.4)
1040
(4.6)
1470
(6.5)
1970
(8.8)
2450
(10.9)
3070
(13.7)
3840
(17.1)
4140
(18.4)
5120
(22.8)
7600
(33.8)
9200
(40.9)

630
(2.8)
670
(3.0)
750
(3.3)
1370
(6.1)
1440
(6.4)
1450
(6.4)
2400
(10.7)
2530
(11.3)
2130
(9.5)
3290
(14.6)
3730
(16.6)
2670
(11.9)
4800
(21.4)
5870
(26.1)
4670
(20.8)
7070
(31.4)
8670
(38.6)

Shear Through The Threads

5120
(22.8)
8140
(36.2)
9200
(40.9)

5870
(26.1)
6320
(28.1)
5070
(22.6)
8400
(37.4)

9200
(40.9)

10670
(47.5)

Shear Through The Bolt Body

2. Values shown are for a shear plane acting through the anchor bolt
body. When the shear plane is acting through the anchor bolt threads,
reduce the shear value by 7%.
All other values shown are for shear plane acting through either body
or threads.

156

5120
(22.8)

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

Anchoring Systems

Kwik Bolt II Expansion Anchor

4.3.3

Carbon Steel Kwik Bolt II Ultimate Loads in Concrete


Anchor
Diameter
in. (mm)

/4

(6.4)

/8

(9.5)

/2

(12.7)

/8

(15.9)

/4

(19.1)

6000 psi (41.4 MPa)

Tension
lb (kN)

Shear
lb (kN)

Tension
lb (kN)

Shear
lb (kN)

Tension
lb (kN)

Shear
lb (kN)

11/8
(29)

1000
(4.4)

1600
(7.1)

1230
(5.5)

1600
(7.1)

1430
(6.4)

1600
(7.1)

1750
(7.8)

1600
(7.1)

22
(51)

2100
(9.3)

3 /4
(95)

2500
(11.1)

2000
(8.9)

2500
(11.1)

2000
(8.9)

15/8
(41)

2000
(8.9)

3900
(17.3)

3200
(14.2)

3900
(17.3)

2 1/21
(64)

4500
(20.0)

4 1/41
(108)

5000
(22.2)

5500
(24.5)

5800
(25.8)

5500
(24.5)

2 1/4
(57)

4400
(19.6)

7360
(32.7)

6500
(28.9)

7360
(32.7)

3 1/2 2
(89)

7000
(31.1)

9200
(40.9)

10500
(46.7)

9200
(40.9)

11500
(51.2)

10000
(44.5)

11500
(51.2)

14200
(63.2)

15700
(69.8)

14200
(63.2)

15500
(68.9)

12000
(53.4)

15500
(68.9)

6
(152)

7800
(34.7)

2 3/4
(70)

6000
(26.7)

42
(102)

9000
(40.0)

72
(178)

12000
(53.4)

3 1/4
(83)

7400
(32.9)

4 3/4 2
(121)

11000
(48.9)

(25.4)

4000 psi (27.6 MPa)

Shear
lb (kN)

3000 psi (20.7 MPa)

Tension
lb (kN)

2000 psi (13.8 MPa)

Embedment
Depth
in. (mm)

8
(203)

15000
(66.7)

4 1/2
(114)

12500
(55.6)

6
(152)

18500
(82.3)

9
(229)

25000
(111.2)

2000
(8.9)
3700
(16.5)
5500
(24.5)
7250
(32.2)
9200
(40.9)
11500
(51.2)
14200
(63.2)
15500
(68.9)
19200
(85.4)
26500
(117.9)
34500
(153.5)

1. Values shown are for a shear plane acting through the anchor bolt
body. When the shear plane is acting through the anchor bolt threads,
reduce the shear values by 15%.

2225
(9.9)
2500
(11.1)
2450
(10.9)
4825
(21.5)
5200
(23.1)
4925
(21.9)
8000
(35.6)
8650
(38.5)
7000
(31.1)
10670
(47.5)
13000
(57.8)
8700
(38.7)
15500
(68.9)
18500
(82.3)
15200
(67.6)
22500
(100.1)
28750
(127.9)

2000
(8.9)
3900
(17.3)
5500
(24.5)
7360
(32.7)
9200
(40.9)
11500
(51.2)
14200
(63.2)
15500
(68.9)
19200
(85.4)
28500
(126.8)
34500
(153.5)

2350
(10.5)
2500
(11.1)
2825
(12.6)
5150
(22.9)
5400
(24.0)
5450
(24.2)
9000
(40.0)
9500
(402.3)
8000
(35.6)
12350
(54.9)
14000
(62.3)
10000
(44.5)
18000
(80.1)
22000
(97.9)
17500
(77.8)
26500
(117.9)
32500
(144.6)

Shear Through The Threads

19200
(85.4)
30500
(135.7)
34500
(153.5)

22000
(97.9)
23700
(105.4)

19200
(85.4)

19000
(84.5)
31500
(140.1)

34500
(153.5)

40000
(177.9)

Shear Through The Bolt Body

2. Values shown are for a shear plane acting through the anchor bolt
body. When the shear plane is acting through the anchor bolt threads,
reduce the shear value by 7%.
All other values shown are for shear plane acting through either body
or threads.

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

157

Anchoring Systems

4.3.3

Kwik Bolt II Expansion Anchor

Kwik Bolt II AISI 304 and 316 Stainless Steel Allowable Loads in Concrete
Anchor
Diameter
in. (mm)

/4

(6.4)

/8

(9.5)

/2

(12.7)

/8

(15.9)

/4

(19.1)

1
(25.4)

158

2000 psi (13.8 MPa)

3000 psi (20.7 MPa)

4000 psi (27.6 MPa)

Embedment
Depth
in. (mm)

Tension
lb (kN)

Shear
lb (kN)

Tension
lb (kN)

Shear
lb (kN)

Tension
lb (kN)

11/8
(29)

240
(1.1)

560
(2.5)

330
(1.5)

570
(2.5)

350
(1.6)

2
(51)

470
(2.1)

33/4
(95)

550
(2.4)

590
(2.6)

550
(2.4)

590
(2.6)

550
(2.4)

15/8
(41)

430
(1.9)

880
(3.9)

490
(2.2)

1010
(4.5)

550
(2.4)

21/2
(64)

930
(4.1)

41/4
(108)

1070
(4.8)

21/4
(57)

850
(3.8)

31/2
(89)

1330
(5.9)

6
(152)

1470
(6.5)

23/4
(70)

1250
(5.6)

4
(102)

1870
(8.3)

7
(178)

2400
(10.7)

31/4
(83)

1550
(6.9)

2880
(12.8)

1950
(8.7)

3310
(14.7)

2350
(10.5)

43/4
(121)

2510
(11.2)

4510
(20.1)

3250
(14.5)

4650
(20.7)

3870
(17.2)

8
(203)

2930
(13.0)

4800
(21.4)

3870
(17.2)

4800
(21.4)

4530
(20.2)

41/2
(114)

3120
(13.9)

6080
(27.0)

3870
(17.2)

6770
(30.1)

4610
(20.5)

6
(152)

4400
(19.6)

9
(229)

5600
(24.9)

1330
(5.9)
1810
(8.1)
2220
(9.9)
2800
(12.5)
3330
(14.8)

7470
(33.2)

1090
(4.8)
1330
(5.9)
1070
(4.8)
1730
(7.7)
1880
(8.4)
1600
(7.1)
2400
(10.7)
3010
(13.4)

6400
(28.5)
8000
( 35.59)

1330
(5.9)
1850
(8.2)
2220
(9.9)
3070
(13.7)
3330
(14.8)

7470
(33.2)

1250
(5.6)
1440
(6.4)
1280
(5.7)
2130
(9.5)
2290
(10.2)

Shear
lb (kN)

590
(2.6)

9390
(41.77)

Shear
lb (kN)

550
(2.4)

590
(2.6)

1150
(5.1)

670
(3.0)

1230
(5.5)

1330
(5.9)

1440
(6.4)

1330
(5.9)

1890
(8.4)

1330
(5.9)

2220
(9.9)

2400
(10.7)

2220
(9.9)

2720
(12.1)
1920
(8.5)

3330
(14.8)

3650
(16.2)

7200
(32.0)

Tension
lb (kN)
370
(1.6)

1810
(8.1)
2930
(13.0)

6000 psi (41.4 MPa)

3200
(14.2)

3330
(12.5)

3650
(16.2)
3730
(16.6)
4800
(21.4)

2610
(11.6)
4670
(20.8)

4800
(21.4)

5120
(22.8)
4800
(21.4)

7470
(33.2)

7330
(32.6)
9390
(41.8)

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

7470
(33.2)

Anchoring Systems

Kwik Bolt II Expansion Anchor

4.3.3

Kwik Bolt II AISI 304 and 316 Stainless Steel Ultimate Loads in Concrete
Anchor
Diameter
in. (mm)

/4

(6.4)

/8

(9.5)

/2

(12.7)

/8

(15.9)

/4

(19.1)

1
(25.4)

2000 psi (13.8 MPa)

3000 psi (20.7 MPa)

4000 psi (27.6 MPa)

Embedment
Depth
in. (mm)

Tension
lb (kN)

Shear
lb (kN)

Tension
lb (kN)

Shear
lb (kN)

Tension
lb (kN)

11/8
(29)

900
(4.0)

2100
(9.3)

1250
(5.6)

2150
(9.6)

1300
(5.8)

2
(51)

1750
(7.8)

33/4
(95)

2070
(9.2)

2200
(9.8)

2070
(9.2)

2200
(9.8)

2070
(9.2)

15/8
(41)

1600
(7.1)

3300
(14.7)

1825
(8.1)

3800
(16.9)

2050
(9.1)

21/2
(64)

3500
(15.6)

41/4
(108)

4000
(17.8)

21/4
(57)

3200
(14.2)

31/2
(89)

5000
(22.2)

6
(152)

5500
(24.5)

23/4
(70)

4700
(20.9)

4
(102)

7000
(31.1)

7
(178)

9000
(40.0)

31/4
(83)

5800
(25.8)

10800
(48.0)

7300
(32.5)

12400
(55.2)

8800
(39.1)

43/4
(121)

9400
(41.8)

16900
(75.2)

12200
(54.3)

17450
(77.6)

14500
(64.5)

8
(203)

11000
(48.9)

18000
(80.1)

14500
(64.5)

18000
(80.1)

17000
(75.6)

41/2
(114)

11700
(52.0)

22800
(101.4)

14500
(64.5)

25400
(113.0)

17300
(77.0)

6
(152)

16500
(73.4)

9
(229)

21000
(93.4)

5000
(22.2)
6800
(30.2)
8340
(37.1)
10500
(4.7)
12500
(55.6)

28000
(124.5)

4100
(18.2)
5000
(22.2)
4000
(17.8)
6500
(28.9)
7050
(31.4)
6000
(26.7)
9000
(40.0)
11300
(50.3)

24000
(106.8)
30000
(133.5)

5000
(22.2)
6950
(30.9)
8340
(37.1)
11500
(51.2)
12500
(55.6)

28000
(124.5)

4700
(20.9)
5400
(24.0)
4800
(21.4)
8000
(35.6)
8600
(38.3)

Shear
lb (kN)

2200
(9.8)

35200
(156.6)

Shear
lb (kN)

2070
(9.2)

2200
(9.8)

4300
(19.1)

2500
(11.1)

4600
(20.5)

5000
(22.2)

5400
(24.0)

5000
(22.2)

7100
(31.6)

5000
(22.2)

8340
(37.1)

9000
(40.0)

8340
(37.1)

10200
(45.4)
7200
(32.0)

12500
(55.6)

13700
(60.9)

27000
(120.1)

Tension
lb (kN)
1400
(6.2)

6800
(30.2)
11000
(48.9)

6000 psi (41.4 MPa)

12000
(53.4)

12500
(55.6)

13700
(60.9)
14000
(62.3)
18000
(80.1)

9800
(43.6)
17500
(77.8)

18000
(80.1)

19200
(85.4)
18000
(80.1)

28000
(124.5)

27500
(122.3)

28000
(124.5)

35200
(156.6)

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

159

Anchoring Systems

4.3.3

Kwik Bolt II Expansion Anchor

Carbon Steel Kwik Bolt II Allowable Loads in Lightweight Concrete

Anchor
Diameter
in. (mm)

Embedment
Depth
in. (mm)
11/8
( 29)

1/4
(6.4)

Shear
2000 psi (13.8 MPa)
lb (kN)
400 ( 1.8)

Tension
2000 psi (13.8 MPa)
lb (kN)
225 (1.0)

Tension
3000 psi (20.7 MPa)
lb (kN)
295 ( 1.3)

Tension
4000 psi (27.6 MPa)
lb (kN)
350 ( 1.6)

2 2

( 51)

500

( 2.2)

325

(1.4)

390

( 1.7)

450

( 2.0)

15/8

( 41)

775

( 3.5)

425

(1.9)

530

( 2.4)

625

( 2.8)

21/2 1

( 64)

1375

( 6.1)

625

(2.8)

810

( 3.6)

975

( 4.3)

21/4

( 57)

1400

( 6.2)

725

(3.2)

920

( 4.1)

1100

( 4.9)

31/2 2

( 89)

2300

(10.2)

1100

(4.9)

1360

( 6.1)

1600

( 7.1)

5/8

23/4

( 70)

2500

(11.1)

1125

(5.0)

1350

( 6.0)

1550

( 6.9)

(15.9)

4 2

(102)

3550

(15.8)

1650

(7.3)

1990

( 8.9)

2300

(10.2)

3/4

31/4

( 83)

3250

(14.5)

1575

(7.0)

1905

( 8.5)

2200

( 9.8)

43/4 2

(121)

4700

(20.9)

2200

(9.8)

2750

(12.2)

3250

(14.5)

3/8

(9.5)
1/2

(12.7)

(19.1)

1. Values shown are for a shear plane acting through the anchor bolt body. When the shear plane is acting through the anchor bolt threads, reduce the shear values by 15%.
2. Values shown are for a shear plane acting through the anchor bolt body. When the shear plane is acting through the anchor bolt threads, reduce the shear values by 7%.
3. Based on using a safety factor of 4.

Carbon Steel Kwik Bolt II Allowable Loads through the Ridge of Metal Profile Deck into Lightweight Concrete
Anchor Diameter
in. (mm)

Embedment Depth
in. (mm)

fc=3000 psi
(20.7 Mpa)

1/4 (6.4)

2 1/4 (57)

560 (2.5)

490 (2.2)

3/8 (9.5)

2 1/4 (57)

790 (3.5)

1000 (4.4)

Tension, lb (kN)

Shear, lb (kN)

1/2 (12.7)

2 1/4 (57)

880 (4.0)

1000 (4.4)

5/8 (15.9)

4 1/2 (114)

1675 (7.4)

2575 (11.4)

Carbon Steel Kwik Bolt II Allowable Loads in Grout Filled Concrete Masonry Units 1, 3, 4, 5, 6, 7
Anchor
Diameter
in. (mm)

Embedment
Depth 2
in. (mm)

/4

11/8

(29)

(6.4)

(51)

1 /8

(41)

2 /2

(64)

/2

2 /4

(57)

(12.7)

31/2

(89)

2 /4

(70)

(102)

31/4

(83)

/8

(9.5)
1

/8

(15.9)

/4

(19.1)

43/4 (121)

Distance from
Edge
in. (mm)
4
12
4
12
4
12
4
12
4
12
4
12
4
12
4
12
16
4
12
16
4
12
16

(101.6)
(304.8)
(101.6)
(304.8)
(101.6)
(304.8)
(101.6)
(304.8)
(101.6)
(304.8)
(101.6)
(304.8)
(101.6)
(304.8)
(101.6)
(304.8)
(406.4)
(101.6)
(304.8)
(406.4)
(101.6)
(304.8)
(406.4)

Tension
lb (kN)

Shear
lb (kN)

200 (0.9)

370

( 1.6 )

410 (1.8)

570

( 2.5 )

430 (1.9)

850

( 3.8 )

725 (3.2)

1050 ( 4.7 )

750 (3.3)

1050
1400
1050
1890
1050
2120
1050
2120
2700
1050
2120
2600
1050
2120
3110

975 (4.3)
1100 (4.9)
1460 (6.5)
1450 (6.5)
1465 (6.5)
1620 (7.2)

( 4.7 )
( 6.2 )
( 4.7 )
( 8.4 )
( 4.7 )
( 9.4 )
( 4.7 )
( 9.4 )
(12.0)
( 4.7 )
( 9.4 )
(11.6)
( 4.7 )
( 9.4 )
(13.8)

1. Values are for Light weight, Medium weight or Normal weight


concrete masonry units conforming to ASTM C90 with 2000 psi
grout conforming to ASTM C474.
2. Embedment depth is measured from the outside face of the
concrete masonry unit.
3. Values are for anchors located in the grouted cell, bed joint,
cross web or any combination of the above.
4. For anchors installed in the T joint or head joint reduce tension values
by 20%.
5. Values for edge distances between 4 inches and 12 inches and
between 12 inches and 16 inches can be calculated by linear
interpolation.
6. Anchors are limited to one per unit cell.
7. Based on using a safety factor of 4.

Countersunk Kwik Bolt II Allowable Loads in Concrete 1


Anchor
Diameter
in. (mm)

/4

(6.4)

/8

(9.5)

Bolt
Material
Carbon Steel
Stainless Steel
Carbon Steel
Stainless Steel

Embedment 3000 psi (20.7 MPa)


Depth
Shear2
Tension
in. (mm)
lb (kN)
lb (kN)
450
350
(2.0)
(1.6)
11/8
(29)
480
500
(2.1)
(2.2)
15/8
(41)

810
(3.6)
880
(3.9)

750
(3.3)
1330
(5.9)

1. Based on using a safety factor of 4.


2. Shear values for shear plane acting thru threads of anchor bolt.

160

HCKB (Hilti Ceiling Kwik Bolt) Allowable Loads1


Anchor
Diameter
in. (mm)

Embedment
Depth
in. (mm)

/4

17/16
(37)

(6.4)

3000 psi (20.7 MPa)


Normal Wt. Concrete
Tension
Shear
lb (kN)
lb (kN)
675
(3.0)

155
(0.69)

3000 psi (20.7 MPa)


Lightweight Concrete
Tension
Shear
lb (kN)
lb (kN)
465
(2.1)

1. Based on using a safety factor of 4.

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

145
(0.65)

Anchoring Systems

Kwik Bolt II Expansion Anchor

4.3.3

Anchor Spacing and Edge Distance Guidelines 1, 2 (See Anchoring Technology Section 4.1.3)
Minimum Embedment

/4

/8

Anchor
in.
Size
(mm)

(6.4)

(9.5)

in.
(mm)

11/8
(29)

15/8
(41)

hmin

/2

/8

/4

(12.7) (15.8) (19.1) (25.4)


21/4
(59)

23/4
(70)

31/4
(83)

41/2
(114)

/4

s
V

Standard Embedment

/4

/8

Anchor
in.
Size
(mm)

(6.4)

(9.5)

in.
(mm)

2
(51)

21/2
(64)

hnom

c
1

/2

/8

(12.7) (15.8) (19.1) (25.4)


31/2
(89)

4
(102)

43/4
(121)

6
(152)

1. For s and c of anchors with actual embedments between the listed embedments, use linear interpolation.
2. For s and c of anchors with embedments greater than the deepest embedment listed, use value for deepest embedment listed.

Anchor Spacing Adjustment Factors


scr

2.0
s
hnom
or
s
hmin

Shear &
Tension

s
hmin
hnom
fA
smin

Actual anchor spacing


Minimum depth of embedment
Standard depth of embedment
Anchor spacing reduction factor for shear and tension
1.0 hnom
for
hef hnom
sc = 2.0 hnom

smin

1.0

=
=
=
=
=

smin = 1.0 hef


scr = 2.0 hef

}
}

for
hmin < hef < hnom

0
0

0.7
1.0
Anchor Spacing Adjustment Factor
(fA)

Edge Distance Adjustment Factors


ccr

1.5

ccr

3.0
Tension

Shear

cmin

1.0
c
hnom
or
c
hmin

cmin

1.5
c
hmin

0
0

c
hmin
hnom
fRN
ccr
cmin

=
=
=
=
=

0.8
1.0
Anchor Edge Distance Adjustment
Factor for Tension
( fRN)

Actual edge distance


Minimum depth of embedment
Standard depth of embedment
Edge distance reduction factor for tension
1.5 hnom
ccr = 1.5 hef
for
hef hnom
= 1.0 hnom
cmin = 1.0 hef

for
hmin hef < hnom

0.5
1.0
Anchor Edge Distance Adjustment
Factor for Shear
( fRV)

c
hmin
hnom
fRV
ccr
cmin

=
=
=
=
=

Actual edge distance


Minimum depth of embedment
Standard depth of embedment
Edge distance reduction factor for shear
3.0 hmin
for
hef hmin
= 1.5 hmin

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

161

Anchoring Systems

4.3.3

Kwik Bolt II Expansion Anchor

Influence of Anchor Spacing and Edge Distance fA, fR (hmin = minimum embedment)
Load Adjustment Factors (Anchor Spacing) fA

Load Adjustment Factors (Edge Distance) fR


Tensile fRN

Shear fRV

Anchor Diameter

Anchor Diameter

Tensile/Shear
Spacing
s
in. (mm)
1

1 /8
15/8
2
21/4
21/2
23/4
31/4
33/4
41/2
5
51/2
6
61/2
7
8
9

( 29)
( 41)
( 51)
( 57)
( 64)
( 70)
( 83)
( 95)
(114)
(127)
(140)
(152)
(165)
(178)
(203)
(229)

Anchor Diameter
1

/4

.70
.83
.93
1.0

/8

/2

/8

/4

Edge
Distance
c
in. (mm)
1

.70
.77
.82
.86
.91
1.0

.70
.73
.77
.83
.90
1.0

.70
.75
.81
.89
.95
1.0

.70
.75
.82
.86
.91
.95
1.0

.70
.73
.77
.80
.83
.87
.93
1.0

1 /8
15/8
2
21/4
21/2
23/4
31/4
33/4
41/2
5
51/2
6
61/2
7
8
9
10
12
14

( 29)
( 41)
( 51)
( 57)
( 64)
( 70)
( 83)
( 95)
(114)
(127)
(140)
(152)
(165)
(178)
(203)
(229)
(254)
(305)
(356)

s + 0.40
hef
for scr > s > smin

/4

/8

.80
.97
1.0

.80
.89
.95
1.0

/2

.80
.84
.89
.98
1.0

/8

.80
.87
.95
1.0

/4

.80
.86
.95
1.0

/4

.50
.59
.67
.74
.81
.96
1.0
.80
.84
.89
.93
.98
1.0

/8

/2

.51
.56
.67
.77
.92
1.0

/8

.54
.61
.67
.73
.79
.85
.97
1.0

/4

.51
.56
.61
.67
.72
.82
.92
1.0

.52
.59
.67
.74
.89
1.0

c
hmin
for ccr > c > cmin

fRN = 0.4 c + 0.40


hef
for ccr > c > cmin

fA = 0.3

.56
.67
.74
.81
.89
.97
1.0

fRV = 0.333

Influence of Anchor Spacing and Edge Distance fA , fR (hnom = standard embedment)


Load Adjustment Factors (Anchor Spacing) fA

Load Adjustment Factors (Edge Distance) fR

Tension/Shear
Spacing
s
in. (mm)
2
21/4
21/2
23/4
31/4
33/4
41/2
5
51/2
6
61/2
7
8
9
10
12
14
16
18

( 51)
( 57)
( 64)
( 70)
( 83)
( 95)
(114)
(127)
(140)
(152)
(165)
(178)
(203)
(229)
(254)
(305)
(356)
(406)
(457)

Anchor Diameter
1

/4

.70
.74
.78
.81
.89
.96
1.0

/8

.70
.73
.79
.85
.94
1.0

/2

.72
.79
.83
.87
.91
.96
1.0

/8

.74
.78
.81
.85
.89
.93
1.0

s + 0.40
hnom
for scr > s > smin

fA = 0.3

162

/4

.72
.75
.78
.81
.84
.91
.97
1.0

.70
.73
.75
.80
.85
.90
1.0

Edge
Distance
c
in. (mm)
2
21/4
21/2
23/4
31/4
33/4
41/2
5
51/2
6
61/2
7
8
9
10
12
14
16
18

( 51)
( 57)
( 64)
( 70)
( 83)
( 95)
(114)
(127)
(140)
(152)
(165)
(178)
(203)
(229)
(254)
(305)
(356)
(406)
(457)

Tension fRN

Shear fRV

Anchor Diameter

Anchor Diameter

/4

/8

.80
.85
.90
.95
1.0

.80
.84
.92
1.0

/2

.83
.91
.97
1.0

/8

/4

/4

.59
.67
.74
.81
.96
1.0
.85
.90
.95
1.0

c + 0.40
hnom
for ccr > c > cmin

fRN = 0.4

.82
.86
.91
.95
1.0

.80
.83
.87
.93
1.0

/8

/2

.51
.56
.67
.77
.92
1.0

.56
.67
.74
.81
.89
.97
1.0

/8

.54
.61
.67
.73
.79
.85
.97
1.0

/4

.51
.56
.61
.67
.72
.82
.92
1.0

.52
.59
.67
.74
.89
1.0

c
hmin
for ccr > c > cmin

fRV = 0.333

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

Anchoring Systems

Kwik Bolt II Expansion Anchor

4.3.3

4.3.3.4 Installation Instructions


Kwik Bolt II Length Identification System
Stamp on Anchor
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
From 1-1/2 2 2-1/2 3 3-1/2 4 4-1/2 5 5-1/2 6 6-1/2 7 7-1/2 8 8-1/2 9 9-1/2 10
Length of Up To
Anchor
But Not 2 2-1/2 3 3-1/2 4 4-1/2 5 5-1/2 6 6-1/2 7 7-1/2 8 8-1/2 9 9-1/2 10 11
(inches) Including

S
11

T
U
12 13

V
14

W
15

X
16

Y
17

Z
18

12

13 14

15

16

17

18

19

Stamp on Anchor
AA
From 19
Length of Up To
Anchor
But Not 20
(inches) Including

YY

ZZ

BB
20

CC
21

DD
22

EE
23

FF
24

GG
25

HH
26

II
27

JJ
28

KK
29

LL
30

MM NN
31 32

OO
33

PP QQ
34 35

RR
36

SS
37

TT UU
38 39

VV WW XX
40

21

22

23

24

25

26

27

28

29

30

31

32

34

35

37

38

39 40

41

;; ;; ;; ;;
33

36

Length
Identification Mark

Kwik Bolt II (Stud Version) Installation Instructions

1. Hammer drill a hole the same


nominal diameter as the Hilti
Kwik Bolt II, with or without the
fixture in placethe Kwik Bolt
II works in a bottomless hole.

2. Clean hole with blow out bulb.

3. Drive the Hilti Kwik Bolt II far


enough into the hole so that at
least six threads are below the
top surface of the fixture, using
a Hilti 2 lb. hammer.

4. Tighten to the recommended


torque value with a torque
wrench, or if torque wrench is
not available, 2 or 3 turns from
the finger tight position to
achieve proper anchor setting.

3. Tighten the torque head with


ordinary wrench until nut
breaks away, leaving only
the free spinning sleeve and
tamper proof fastener.

4. Free turning protective sleeve


and tamper proof fastener
remain.

Hilti Tamper Proof Nut (HTN) Installation Instructions

1. Hammer drill a hole the same


nominal diameter as the Hilti
Kwik Bolt II with or without the
fixture in place. Clean hole
with a blow out pump or
compressed air.

2. Put protective sleeve and


tamper proof nut on Kwik Bolt
II so impact section (dog point)
is exposed. Drive anchor far
enough into the hole so that at
least six threads are below the
top surface of the fixture.

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

163

Anchoring Systems

4.3.3

Kwik Bolt II Expansion Anchor

Countersunk Kwik Bolt II Installation Instructions


1. Drill

2. Clean

6. Tighten

5. Tap-in again

4. Loosen
screw 2
full
turns

3. Thread
Post Nut
completely
onto
anchor.
Tap into
hole

Kwik Bolt II Rod Coupling Installation Instructions

1. Drill

2. Clean

3. Tap-in

4. Tighten

Hilti Ceiling Kwik Bolt (HCKB) Installation Instructions

1. Drill

164

2. Tap-in

3. Pry downward

4. Secure

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

Anchoring Systems

Kwik Bolt II Expansion Anchor

4.3.3

4.3.3.5 Ordering Information

Stud Version

Stud VersionExtra Thread

Countersunk Version

Rod Coupling

HCKB

Hilti Tamper Proof Nuts (HTN)


Description

Fits Bolt Size in.

Embedment

Item No.

Box Qty

Use With

Torque ft-lb

38 HTN

3/8

All

00071689

50

All 3/8" HKBII

23

12 HTN-M

1/2

hmin

00071690

50

1/2" HKBII

40

12 HTN-SD

1/2

hnom

00071691

50

1/2" HKBII

65

12 HTN-CSM

1/2

hmin

00248311

50

1/2" HKBII

65

58 HTN-SD

5/8

hnom

00071699

25

5/8" HKBII

110

HTN Removal Tool


Description

Item No.

For HTN Size

HTN Removal Tool 38


HTN Removal Tool 1258

00070973
00260212

3/8
1/2

Standard

Conical

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

165

Anchoring Systems

4.3.3

Kwik Bolt II Expansion Anchor


Item Number

Description
Diameter x Length
in.
1/4 x 13/4
1/4 x 2

3/4

(3/16" thread)

1/4 x 21/4
1/4 x 3

(3/16" thread)

1/4 x 31/4
1/4 x 4

(3/16 thread)

1/4 x 41/2
1/4 x 5

(3/16 thread)

3/8 x 21/4
3/8 x 3

3/8 x 33/4
3/8 x 4
3/8 x 5
3/8 x 7
1/2 x 23/4
1/2 x 33/4

1/2 x 41/2

1/2 x 51/2
1/2 x 7
5/8 x 3 3/4
5/8 x 43/4
5/8 x 6
5/8 x 7
5/8

x 81/2

5/8 x 10
3/4 x 43/4 1

3/4 x 51/2

3/4 x 7
3/4 x 8
3/4 x 10
3/4 x 12

1x6
1x9
1 x 12

Thread
Length
in. (mm)

(5/16 thread)

( 19)
( 11)
3/4
( 19)
7/16
( 11)
3/4
( 19)
7/16
(11)
3
( 76)
7/16
( 11)
7/8
( 22)
11/8 ( 28)
13/4 ( 44)
11/8 ( 28)
21/2 ( 38)
9/16
( 15)
11/8 ( 28)
31/4 ( 82)
4
(101)
11/4 ( 32)
11/4 ( 32)
21/4 ( 57)
11/4 (32)
3
( 76)
11/4 (32)
3
( 76)
4
(101)
11/2 ( 38)
11/2 ( 38)
21/2 ( 63)
11/2 ( 38)
11/2 ( 38)
4
(101)
1
3 /2 ( 89)
41/2 (114)
11/2 (38)
21/2 (63)
11/2 (38)
31/2 (89)
11/2 (38)
41/2 (114)
11/2 (38)
---- ---41/2 (114)
41/2 (114)
21/4 (57)
21/4 (57)
41/2 (114)
7/16

Threads
Box
per Inch Quantity
20
24
20
24
20
24
20
24

100

16

18
16
50

13

25
11

20

10
10

Carbon
Steel
00045359
---00045360
---00045361
---00045378
00045362
00045363
00331952
00045364
00331953
---00045365
00331954
00242538
00045366
00045367
00331955
00045368
00331956
00045369
00331957
00045379
00045370
00045371
00331958
00045372
00045373
00331959
00045380
00045381
00045374
00331960
00045375
00331961
00045376
00332044
00045377
---00332045
00045415
00045412
00045413
00045416

304
Stainless
Steel

316
304Stainless Carbon
Stainless Carbon Steel
Steel
Steel Rod
Steel
Countersunk 2 Countersunk 2 Coupling

00230984
---00230985
---00230986

------00238483
---00238484
------------00238486
---00238487
------------------00238491
---00238493
---00238492
------00045475
00045476
---00045477
-----------00045479
---00045480
---------------00045490
---00045483
-------

00045404
--00230394
00230395
00331962
00230396
00331963
---00230397
00331964
00045405
00229232
00229223
00331965
00229077
00331966
00229234
00331967
00229235
00045394
00045395
00331968
00045396
------00045407
00045408
00045398
00331969
00045399
00331970
00045400
---00045401
---00045409
00045410
00045402
00045403
00045411

---00045427
---00045428
---00045429
---00045431
00045431
00045432
---------00045433
00045434
----

---------00045435
---------------------------00045436

------------------------00045438

1. With 2" O.D. washer.


2. Round Post Nut heads available on special order. Contact the Hilti Customer Service Department for details.

166

US: 1-800-879-8000 / www.us.hilti.com Hilti Product Technical Guide 2002 Canada: 1-800-363-4458 / www.ca.hilti.com

HCKB
------0029630

You might also like