You are on page 1of 4

Lesson Two: Reading a Pump Performance

Curve
Contents
Pump Size
Pump Speed (RPMs)
Flow
Head
Trimmed Impeller curves
Duty Point
Brake Horsepower
End of Curve Horsepower
Return to Table of Contents
Let's take a look at a pump curve, the common way of showing a centrifugal pump's performance.
Pump Size Number
The size of the pump, 1-1/2 x 3 - 6 is shown in the upper part of the pump curve illustration. Note that
the size number 1-1/2 x 3 - 6 indicates that the pump has a 1-1/2 inch discharge port, a 3 inch suction
port, and a maximum nominal impeller size of 6 inches. This type of nomenclature is common, with
some companies putting the 3 in the first position instead of the 1-1/2. In either case, standard
procedure is that the suction port is the larger of the first two numbers shown and the largest of the
three numbers is the nominal maximum impeller size.
Return to Table of Contents
Return to Top of Lesson Two
Pump Speed in RPMs
Also in the upper right hand corner notice that the curve indicates performance at the speed of 3450
RPM (a common electric motorspeed in 60 hz countries). All the information given in the curve is
valid only for 3450 RPM. Generally speaking, curves which indicate RPM to be between 3400 and
3600 RPM are used for all two pole (3600 RPM nominal speed) motors applications.
Return to Table of Contents
Return to Top of Lesson Two
Flow
The pump's flow range is shown along the bottom of the performance curve. Note that the pump,
when operating at one speed, 3450 RPM, can provide various flows. The amount of flow varies with
the amount of head generated. As a general rule with centrifugal pumps, an increase in flow causes a
decrease in head.
Return to Table of Contents
Return to Top of Lesson Two
Head
The left side of the performance curve indicates the amount of head a pump is capable of generating.
Trimmed Impeller Curves
Notice that there are several curves which slope generally downward as they move from left to right
on the curve. These curves show that actual performance of the pump at various impeller diameters.
For this pump the maximum impeller diameter is shown as 6 inches and minimum is 3 inches.
Impellers are trimmed in a machine shop to match the impeller to the head and flow needed in the
application.
Return to Table of Contents
Return to Top of Lesson Two
Duty Point
The point on the curve where the flow and head match the application's requirement is known as the
duty point. A centrifugal pump always operates at the point on it's performance curve where its head
matches the resistance in the pipeline. For example, if the pump shown above was fitted with a 6 inch
impeller and encountered 100 feet of resistance in the pipeline, then it would operate at a flow of
approximately 240 gallons per minute and 100 feet of head. It is important to understand that a
centrifugal pump is not limited to a single flow at a given speed. Its flow depends on the amount of
resistance it encounters in the pipeline. To control the flow of a centrifugal pump it is normally
necessary to restrict the discharge pipeline, usually with a valve, and thus set the flow at the desired
rate. Note: Generally speaking, do not restrict a pump's flow by putting a valve on the suction line.
This can cause damage to the pump!
Return to Table of Contents
Return to Top of Lesson Two
Brake Horsepower (BHP)
Along the bottom of this performance curve are brake horsepower lines sloping upward from left to
right. These lines correspond to the performance curves above them (the top performance curve
corresponds to the top BHP line, and so on). These lines indicate the amount of driver horsepower
which is required at different points of the performance curve. The lines correspond to a BHP
horsepower scale on the lower right hand corner of the page. In our example operating point at 120
gpm and 150 feet of head we observe that the corresponding BHP line equals about 6.8 horsepower.
See the chart below.
Return to Table of Contents
Return to Top of Lesson Two
End of Curve Horsepower
When sizing a motor driver to fit an application it is necessary to consider whether the pump will ever
be required to operate at a flow higher than the duty point. The motor will need to be sized
accordingly. If the pump may flow out to the end of the curve (if someone opens the restriction valve
all the way, for example) it is important that the motor does not become overloaded as a result.
Therefore it is normal practice to size the motor not for the duty point, but for the end of curve
(EOC) horsepower requirements. In the example shown below, a 7-1/2 hp motor would adequately
power the pump at a duty point of 120 gpm at 150 feet. But notice that the end of curve brake
horsepower requires that a 10 hp motor be used.
Return to Table of Contents
Return to Top of Lesson Two
Proceed to Lesson Three

You might also like