Ceiling Systems
Installation Guide
Gyprock
plasterboard sheet w hich is fixed to appropriately prepared
fram ing. P lasterboard joints are taped and setto form
a sm ooth flush jointedcontinuous ceiling suitable for
painting.
G yprock
Plasterboard
C eiling Panels, C SR Ecophon Panels, U SG C eiling Panels or
C SR Fricker C eiling Tiles. These panels are generally placed
in a tw o-w ay grid w hich is suspended below floor or roof
fram ing. Ecophon panels are also available to fix directly to
battens or existing plasterboard ceilings.
G yprock Plasterboard C eiling Panels have a plasterboard
core, and are used as decorative linings in com m ercial
applications. They can also be used in system s to reduce
the transfer of noise over partitions.
U SG C eiling Panels Panels have a m ineral fibre core w hich
provides m oderate to high levels of acoustic absorption.
They are available in a variety of surface textures and edge
details.
C S R Ecophon
plasterboard
w hich is fixed to the underside of
the fram ing is jointed using tape
and com pounds to C S R G yprock
specifications to form sm ooth ceiling
surfaces for decorative coating.
Plasterboard screw fixed above and
below Lipped Steel C-Stud
Plasterboard screw fixed below Lipped
Steel C-Stud
G yprock Panel C eiling System s offer lightw eight, decorative and/or acoustic solutions for com m ercial applications. They are
installed w ith a tw o-w ay suspended grid or direct fixed to battens or an existing plasterboard ceiling.
The precoated face of the supporting grid or edge profile of the panels com bine w ith various surface textures to form a decorative
feature ceiling.
Kerfed edge
Gyprock
Plasterboard C D is m anufactured to AS2588 G ypsum
P lasterboard, and incorporates C D (C ontrolled D ensity)
technology. G yprock Plasterboard C D is suitable for internal
w alls and ceilings.
Gyprock Supaceil
is com posed
of a specially processed glass fibre reinforced gypsum core
encased in a heavy duty pink liner board.
Gyprock Fyrchek MR
is
com posed of a specially processed glass fibre reinforced
gypsum core w hich is treated in m anufacture to w ithstand
the effects of m oisture, and encased in a heavy duty light
blue liner board.
Gyprock Flamechek MR
Flexible
Plasterboard is 6.5m m thick and is installed in tw o layers.
Gyprock
0 1
10 - 13m m SO U N D C H EK
0 1
10 13m m AQ U AC H EK 0 1
6.5m m FLEXIB LE 0 1
13m m Perforated Sheet 0 1
13 16m m FYR C H EK
0 1
13 16m m FYR C H EK M R
0 1
25m m SH AFT LIN ER PAN EL 0 1
10m m FLAM EC H EK M R
0 1
N O TES: SM O G R AR C = Sm oke G row th R ate Index.
Fire Hazard Properties
The B C A lim its the m aterials used in C lass 2 to 9 buildings
by controlling the Fire H azard properties of linings. These
properties are assessed using AS/ISO 9705 room burn test
or AS/N ZS3837 the cone calorim eter test. The room burn
test is a large scale test to determ ine SM O G R AR C , and the
cone calorim eter is a sm all scale test to determ ine a G roup
N um ber.
GYPROCK
COVE CORNICE
GYPROCK
J AZZ CORNICE
GYPROCK
TEMPO CORNICE
GYPROCK
CLASSIC CORNICE
GYPROCK
SYMPHONY CORNICE
GYPROCK
CONCERTO CORNICE
Gyprock
Cornice
C S R G yprock m anufactures six popular m achine m ade
cornice profiles w hich cater for m any styles and applications.
P lease refer to P roduct Availability table in this section
for detailed product size and availability inform ation. It is
recom m ended that cornice be attached w ith G yprock
C ornice C em ent.
GYPROCK
SHADOWSET
FLUSH
GYPROCK
SHADOWSET
PLANT-ON
1
2
0
0
m
m
1
0
5
0
m
m
Overall 3600mm
450mm
75mm
nom.
150mm 450mm
FIG 2: GYPROCK PERFORATED PLASTERBOARD
DIMENSIONS
Gyprock
PRODUCT AVAILABILITY
C olour shading behind each product approxim ates the colour of the product face liner sheets.
G yprock Product
Thickness
m m
W idth
m m
Sheet Length (m m ) M ass
kg/m
2 2400 2700 3000 3600 4200 4800 5400 6000
C D R EC ESSED ED G E
10
1200 W W W W W W W W
6.5
1350 W W W W W W
13
900 *W SN W W
8.5 1200 SN W SN W SN
1350 SN W
C D SQ U AR E ED G E
10 1200 W SN W SN W 6.5
13 1200 SN SN 8.5
C D R EC ESSED ED G E/
SQ U AR E ED G E
10
1200 W
6.5 1210 W
1350
SU PAC EIL
10
900 W W W W
7.2 1200 SN W
1350 W
SO U N D C H EK
10 1350 9.3
13 1200 13.0
AQ U AC H EK
10
1200 SN
8.0
1350 SN SN W SN SN W SN
13 1200 W W 10.4
IM PAC TC H EK
10 1350 6.5
13 1200 10.3
FLEXIB LE 6.5 1200 4.25
FLAM EC H EK M R
10 1350 8.0
FYR C H EK
13 1200 W 10.5
16 1200 SN W 12.5
FYR C H EK
M R
13 1200 W SN SN 10.7
16 1200 W SN W SN 13.5
PER FO R ATED SH EET
13 1200 10.0
SH AFT LIN ER PAN EL 25 600 19.8
C O VE C O R N IC E
55 0.7kg/m
75 W W N T 0.9kg/m
90 1.3kg/m
C LASSIC
C O R N IC E 90 1.2kg/m
TEM PO
C O R N IC E 90 1.8kg/m
SYM PH O N Y
C O R N IC E 75 0.9kg/m
C O N C ER TO
C O R N IC E 90 1.6kg/m
JAZZ
C O R N IC E 75 1.8kg/m
SH AD O W SET
105 1.0kg/m
Indicates available in: = All States & Territories; W = W estern Aust.; S = South Aust.; N = N orthern Territory.
Indicates N O T available in: W = W estern Aust.; S = South Aust.; N = N orthern Territory.
* = Length is 2740. = 3300 and 3900m m lengths also available in W A only.
In W estern Australia only, additional R ecessed Edge/Square Edge products are available.
Additional sizes m ay be available in som e products. C all your state office for details.
Gyprock
Resilient Mount
The G yprock
plasterboard to a
supporting structure
w hile sim ultaneously
iso lating it fro m
stru ctu re b o rn e
vibration.
This significantly
re d u c e s th e
am ount of im pact
noise, speech and
lo w freq uency
so und filtering
through to room s
a b o ve , b e lo w
o r a lo n g s id e
t h e n o is e
g enerating ro o m . T he resilient m o unt has b een
d esig n fo r use o n ceiling s and can b e used o n
w alls provided plasterboard w ith m inim um m ass of
13kg/m
2
is fixed on the resilient m ount side of the w all. The
m ount can be used in fire rated and non fire rated system s.
G yprock
C louts.
2.8, 3.15 and 3.75m m
dia. (hot-dip galvanised) for fixing to tim ber.
G yprock
Type W Screw s.
#6 and #8 for fixing to
tim ber.
G yprock
1
2
9
)
2
8
m
m
(
N
3
0
8
)
2
0
m
m
24mm
4.5mm
Furring Channel
N129 or N308
Gyprock
Resilient
Mount
GYPROCK Plasterboard
J ointing & Finishing
C SR G yprock has a w ide range com pounds, cem ents and
accessories for finishing plasterboard installations.
This m anual does not provide plasterboard jointing and
finishing details.
It should be noted that m ulti-layered system s only require
jointing and finishing of the outer layer.
Inform ation relating to the jointing and finishing of G yprock
plasterboard can be found in the G yprock
Plasterboard
Installation M anual, N G YP547, or visit the G yprock
W eb
site w w w .gyprock.com .au
Gyprock
plasterboard sheets
600mm
maximum
STACKING AND SUPPORT
OF PLASTERBOARD SHEETS
Gyprock
R esilient M ounts
at 1200m m centres m axim um along the furring channel,
can support a m axim um of 3 layers x 16m m G YP R O C K
FYR C H EK and lightw eight insulation.
End of furring channels 10mm
clear of wall face
Gyprock Resilient Mounts at
appropriate centres to suit
chosen system
F
u
rrin
g
C
h
a
n
n
e
l S
p
a
c
in
g
(6
0
0
m
m
m
a
x
im
u
m
c
e
n
tre
s
)
Timber or Steel
support structure
F
u
r
r
in
g
C
h
a
n
n
e
l S
p
a
n
Refer to chosen perimeter
detail for appropriate
positioning of first and last
furring channel
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)
N553 Angle or N140 /142Track
fixed to wall at ends and 600mm
max. centres between
FIG 10: STEEL FURRING CHANNEL FIXED WITH RESILIENT MOUNTS TO FRAMING
FIG 9: GYPROCK RESILIENT MOUNT FIXING
Adjustable Direct Fix
Bracket NCSR4
(when required)
GYPROCK
Resilient Mount
Furring Channel
N129/308
GYPROCK
FYRCHEK
Plasterboard
(max. 3 layers
x 16mm)
GYPROCK
Mounting Screw
R efer to span tables in this guide and R ondo B uilding
Services specifications for alternative grid span and spacing
inform ation.
FIRE RATED NON FIRE RATED
Gyprock
Fire
M astic. In som e cases, verm iculite plaster m ay be used. (Refer
to appropriate details). Verm iculite for caulking is to be m ixed
3:2 by volum e w ith cornice cem ent. U se sufficient w ater to
achieve a stiff w orkable m ix. Verm iculite plaster is not to be used
as a general purpose acoustic or fire rated caulking, except
w here detailed in this m anual. Verm iculite has no capacity to
accom m odate building m ovem ent.
In non fire rated system s, to attain the stated acoustic rating,
fill all gaps and around penetrations w ith G yprock W et Area
Acrylic Sealant or G yprock Fire M astic.
Curved Ceilings
For details on plasterboard fixing to curved ceilings, refer to
the G yprock Steel Fram e W all System s Installation G uide,
N G YP544.
Plasterboard J ointing & Finishing
R efer to the G yprock Plasterboard R esidential Installation
G uide, N G Y P 547 for detailed jointing and finishing
inform ation.
For non fire rated ceilings, inform ation is provided for various
Levels of Finish, including tolerances, back-blocking and
fastener spacing.
In m ulti-layer system s, jointing and finishing is required on
the visible outer layer only.
Laminating Screws
In 2 and 3 layer ceiling system s, G yprock
Lam inating
Screw s (40m m x N 10) m ay be used to lam inate layers of
plasterboard together at butt joints and control joints form ed
betw een fram ing.
FIRE RATED NON FIRE RATED
Gyprock
Lam inating
Screw s (40m m x N 10) at 200m m m axim um centres.
Fasten ends of sheets at a 200m m m axim um centres for
a cornice finish, or at a 150m m m axim um centres for a
set finish.
200mm max.
150/200mm max.
200mm
max.
150mm
max.
150mm
max.
Butt Joints in 3rd layer
must be placed centrally
between framing, offset
600mm minimum in adjoining
sheets and from previous layers
Begin 1st layer with 400mm width sheet
Begin 2nd layer with 800mm width sheet
Begin 3rd layer with full width sheet
1st and 2nd layer
Butt Joints on
framing members,
offset 600mm minimum
between layers
Suspended Grid, Steel
Framing or Timber Framing at
600mm maximum centres
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)
FIG 25: INSTALLATION DETAIL THREE LAYER FIXING TO STEEL OR TIMBER FRAMING NAIL OR SCREW FIXING
Fixing & Spacing
Fasten to each framing
member at
10 to 16mm from sheet
edges and at 200mm
maximum centres
6 fasteners equally spaced
7 fasteners equally spaced
8 fasteners equally spaced
Butt J oint on framing and
fasten at 150mm max.
centres.
Butt J oint within
50mm of centre line
between framing and
fix to previous layer with
Laminating Screws at
200mm max. centres
Cornice finish, fasten at
200mm max. centres
Set finish, fasten at
150mm max. centres
Fasten at
150mm max. centres
Location
Body of
Sheet
All Layers
Sheet
Width
900mm
1200mm
1350mm
Butt
J oints
1st & 2nd
Layers
Butt
J oints
3rd layer
Sheet
Ends
Openings
Fixing Specifications
Fasteners Refer to Fastener Details
FIRE RATED
Gyprock
Fire Mastic
min. 16mm depth
Backing rod
(non fire rated)
Framing to appropriate detail
FIG Z140
Suitable for 2 and 3 layer plasterboard ceiling systems.
Caulking Details for Fire Rated Ceilings
Perim eter caulking details Z140 to Z147 w ill m aintain the FR L of the C SR G yprock ceiling system s in w hich they are installed.
These details (excluding Z146 and Z147) are also suitable w here acoustic integrity is required.
Shadowline stopping bead
Rondo P50
W
a
l
l
S
y
s
t
e
m
Framing to appropriate detail
Continuously fill gap at
edge of sheet with
CSR Gyprock
Fire Mastic
min. 16mm depth
FIG Z141
Suitable for 2 and 3 layer plasterboard ceiling systems.
Trowel on a continuous
25 x 25mm fillet
of Vermiculite plaster
W
a
l
l
S
y
s
t
e
m
Framing to appropriate detail
6mm max. gap
FIG Z142
Suitable for 1, 2 and 3 layer plasterboard ceiling systems.
Continuously fill gap at
edge of all sheets with
CSR Gyprock
Fire Mastic
6mm gap min.
W
a
l
l
S
y
s
t
e
m
Framing to appropriate detail
FIG Z143
Suitable for 2 and 3 layer plasterboard ceiling systems.
W
a
l
l
S
y
s
t
e
m
Continuously fill gap at
edge of all sheets with
vermiculite plaster
6mm gap min.
Tape and set joint
Framing to appropriate detail
FIG Z144
Suitable for 1, 2 and 3 layer plasterboard ceiling systems.
W
a
l
l
S
y
s
t
e
m
Continuously fill gap at
edge of all sheets with
Vermiculite plaster
6mm gap min.
Timber moulding
Framing to appropriate detail
FIG Z145
Suitable for 1, 2 and 3 layer plasterboard ceiling systems.
200mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
Masonry
wall system
Refer to FIG Z100
600mm max.
FIG Z129 FIG Z130
CEILING PERIMETER FRAMING AT J UNCTION WITH MASONRY WALL
FIRE RATED
Gyprock
Insulation
Apply sealant
above track and fix
wall track to ceiling
framing
FIG Z802: WALL/CEILING J UNCTION
13mm GYPROCK
plasterboard CD
Tape and
set corner
Ceiling Framing
1200mm min. 1200mm min.
Bradford 75mm
Anticon
Insulation
100mm
min
6mm gap
max.
70mm max.
Wall Angle Trim
Rondo DUO 5 fixed to
wall with metal
fasteners at 600mm
max. centres
NOTE: Wall surface
behind angle must be
flush. Fill any raked
joints behind angle.
Masonry
wall system
FIG Z146:
Suitable for 1, 2 and 3 layer plasterboard ceiling systems.
NOTE: This detail is not suitable were acoustic integrity is
required.
22mm IBS rod
Shadowline stopping bead
Rondo P50
W
a
l
l
S
y
s
t
e
m
Framing to appropriate detail
FIG Z147;
Suitable for 2 and 3 layer plasterboard ceiling systems.
NOTE: This detail is not suitable were acoustic integrity is
required.
FIRE RATED
NON FIRE RATED
Gyprock
Fire Mastic to depth
of first layer minimum
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
Furring
Channel
60 to 70mm
RONDO P35
Control Joint
with set finish
2 layers GYPROCK
FYRCHEK
plasterboard screw
fixed to furring each
side of joint at 200mm
max. centres
15 to 20mm gap
FIG Z034: CONTROL J OINT
PARALLEL TO STEEL FRAMING 2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock
Fire Mastic to depth
of first layer minimum
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Furring
Channel
each side
of joint
60 to 70mm
RONDO P35
Control Joint
with set finish
1st and 2nd layers of
GYPROCK FYRCHEK
plasterboard fixed to
furring at 200mm max.
centres
3rd layer of GYPROCK
FYRCHEK plasterboard
fixed with laminating screws
at 200mm max. centres
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
FIG Z037: CONTROL J OINT
PARALLEL TO STEEL FRAMING 3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock
Fire Mastic to depth
of first layer minimum
Furring Channel
Joiner N138
Back-block between furring
channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet
200mm min.
RONDO P35
Control Joint
with set finish
Furring Channel
GYPROCK FYRCHEK
plasterboard fixed with
laminating screws to
layer above at 200mm
max. centres
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
FIG Z035: CONTROL J OINT
PERPENDICULAR TO STEEL FRAMING 2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock
Fire Mastic to depth
of first layer minimum
Back-block between furring
channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet
200mm min.
RONDO P35
Control Joint
with set finish
2nd and 3rd layers of
GYPROCK FYRCHEK
plasterboard fixed with
laminating screws to
layer above at 200mm
max. centres
Furring Channel
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
FIG Z038: CONTROL J OINT
PERPENDICULAR TO STEEL FRAMING 3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
Furring
Channel
60 to 70mm
RONDO P35
Control Joint
with set finish
1 layer GYPROCK
FYRCHEK
plasterboard screw
fixed to furring
channel each side of
joint at 200mm max.
centres
FIG Z073: CONTROL J OINT
PARALLEL TO STEEL FRAMING 1 LAYER
(Maintains FRL of the ceiling system in which it is installed).
Back-block between furring
channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet
200mm min.
RONDO P35
Control Joint
with set finish
Furring Channel
GYPROCK FYRCHEK
plasterboard fixed to
N140 Track at 200mm
max. centres
Rondo N140 Track
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
FIG Z074: CONTROL J OINT
PERPENDICULAR TO STEEL FRAMING 1 LAYER
(Maintains FRL of the ceiling system in which it is installed).
FIRE RATED
Gyprock
Fire Mastic to depth
of first layer minimum
Back-block between trimmers
with GYPROCK FYRCHEK same
thickness as ceiling sheet
Laminating screws at
200mm max. centres
RONDO P35
Control Joint
with set finish
200mm min.
Laminating screws at
200mm max. centres
GYPROCK
FYRCHEK
plasterboard
Joist Joist
Trimmers at 450mm
max. centres
15 to 20mm gap
FIG Z040: CONTROL J OINT
PARALLEL TO TIMBER FRAMING 2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock
Fire Mastic to depth
of first layer minimum
Back-block between trimmers
with GYPROCK FYRCHEK same
thickness as ceiling sheet
Laminating screws at
200mm max. centres
200mm min.
Laminating screws at
200mm max. centres
GYPROCK
FYRCHEK
plasterboard
Joist
300mm min.
RONDO P35
Control Joint
with set finish
Aluminium Foil under joist,
300 x 150 x 0.15mm
15 to 20mm gap
FIG Z041: CONTROL J OINT PERPENDICULAR TO
TIMBER FRAMING 2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap with CSR
Gyprock
Fire Mastic to depth
of first layer minimum
Back-block between trimmers
with GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix back-block to ceiling sheet
with plaster based adhesive
or laminating screws
RONDO P35
Control Joint
with set finish
200mm min.
Fix 2nd and 3rd layers to
preceeding layer with
laminating screws at 200mm
max. centres
GYPROCK
FYRCHEK
plasterboard
Joist Joist
Trimmers at 450mm
max. centres
15 to 20mm gap
FIG Z043: CONTROL J OINT
PARALLEL TO TIMBER FRAMING 3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously and
completely fill gap
with CSR Gyprock
Fire Mastic
Laminating screws at
200mm max. centres
10 to 12mm gap
RONDO
Stopping Bead
with set finish
1 layer GYPROCK
FYRCHEK plasterboard
continuous across joint
FIG Z042: CONTROL J OINT PARALLEL OR
PERPENDICULAR TO TIMBER OR STEEL FRAMING
2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
NOTE: Aluminium Foil
must be placed under
joist where control joint is
perpendicular to framing.
Refer to FIG Z041.
NOTE: Control J oint must be placed
centrally between joists when
installed parallel to framing
Continuously and
completely fill gap
with CSR Gyprock
Fire Mastic
Laminating screws at
200mm max. centres
10 to 12mm gap
RONDO
Stopping Bead
with set finish
2 layers GYPROCK
FYRCHEK plasterboard
continuous across joint
FIG Z045: CONTROL J OINT PARALLEL OR
PERPENDICULAR TO TIMBER OR STEEL FRAMING
3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
NOTE: Aluminium Foil must
be placed under joist where
control joint is perpendicular to
framing. Refer to FIG Z044.
NOTE: Control J oint must be placed
centrally between joists when
installed parallel to framing
FIRE RATED
Gyprock
C ornice C em ent or
G yprock B ase C oat 45 or 60.
Timber flooring
Floor Joist
Trimmers
50 x 50mm min.
1 or 2 layers of GYPROCK
FYRCHEK plasterboard
Floor Joist
Trimmer
50 x 50mm min.
Nogging
50 x 50mm min.
FIG Z057: RECESSED LIGHT CAVITY
IN TIMBER FRAME
(M aintains the FR L of the w all system in w hich it is installed).
Framing Detail
FIRE RATED
Gyprock
Lam inating Screw s at 200m m m axim um centres.
Steel Beam
Rondo Wall
Furring Track
N140 held in
back tongue of
Universal Clip
FIG 27: GYPROCK
Plasterboard Panels
G yprock
Ceiling Panels
Ecophon
15 or 19m m thick
m ineral fibre panels
w ith three edge
options.
True non-directional
texture allow s
installation in any
direction.
A fresh, clean look
adapts to any interior.
Gyprock
Wall Angle
Standard
22mm
19mm
Donn
CL315
Suspension Clip
Donn
Wall Angle
Long
Donn
CL315
Suspension Clip
40mm
19mm
FIG 34: TYPICAL INSTALLATION DETAIL DONN
COMPONENTS
Gyprock
D iam ond W hite
0 1
10m m SU PATO N E
0 1
10 13m m U npainted Panel 0 1
U SG Eclipse C lim aPlus 31* 1
U SG Im pressions C lim aPlus 7.4* 1
U SG M ars C lim aPlus 149* 1
U SG O lym pia M icro C lim aPlus 26* 1
U SG R adar C lim aPlus 7.4* 1
Ecophon AD VAN TAG E 0 1
Ecophon FO C U S 0 1
N O TES: SM O G R AR C = Sm oke G row th R ate Index.
* Average Specific Extinction Area
Grid Installation
The follow ing inform ation assum es the room is square and
the ceiling panels are to be installed in a standard square-on-
square pattern. Installation m ethods w ill need to be m odified
to allow for out of square room s or other grid patterns, such
as brick pattern, and to allow for light fittings, etc.
For best appearance, the panels closest to the w alls m ay
need to be cut to size to provide a sym m etrical pattern. To
determ ine the position of the grid, determ ine the num ber
of 1200m m panels that w ill fit the room dim ension.
D eterm ine any rem ainder and add 1200m m . D ivide this
total by 2. This is the m argin along each side of the room .
N ow determ ine the num ber of 600m m panels that w ill fit
the room dim ension. D eterm ine any rem ainder and add
600m m . D ivide this total by 2. This is the m argin at each
end of the room .
Example Grid Calculations:
M ain Tee G rid
4000 1200 = 3.3 m odules
4000 3600 (3 panels) = 400
400 + 1200 = 1600
1600 2 = 800 m argin on each side of the room .
C ross Tee G rid
5000 600 = 8.3 m odules
5000 4800 (8 panels) = 200
200 + 600 = 800
800 2 = 400 m argin at each end of the room .
800
Margin
800
Margin
1200 1200
400 Margin
400 Margin
600
600
600
600
600
600
600
4000
5000
Main
Tee
Cross
Tee
TYPICAL GRID LAYOUT
Design
Considerations
Suspension Systems
G yprock
or U SG D onn
products
to be free of defects in m aterials and m anufacture.
If a C SR product does not m eet our standard, w e w ill, at our
option, replace or repair it, supply an equivalent product, or
pay for doing one of these.
C S R recom m ends that only products, com ponents and
system s recom m ended by it be used. If this is not done,
C SR w ill need to be satisfied that any defect in its product
is attributable to our failure to m eet our standard (and not
another cause) before this guarantee applies.
This guarantee excludes all other guarantees and liability for
dam age or loss in connection w ith defects in C SR 's product,
other than those im posed by legislation.