Ceiling Systems
Installation Guide
Gyprock

Ceiling Systems Installation Guide


2
Contents
Introduction 2 3
Flush J ointed Ceiling Systems
C om ponents 4 8
H andling & Storage 8
Framing
G eneral R equirem ents 9 10
D irect Fixed Steel Furring 11
R esilient M ounted Furring C hannel 12
Suspended C oncealed G rid 13
Suspension C om ponents 14
B ulkheads 15
C urved C eilings 16
B utt Joints in C eilings 17
Steel Frame Ceilings Lined One/Both Sides
C eilings Lined O ne Side 18 20
C eilings Lined Tw o Sides 21 23
Plasterboard Fixing
G eneral R equirem ents 24 25
Perforated Plasterboard System s 26
N on Fire R ated Plasterboard System s 27 29
Fire R ated Plasterboard System s 30 31
Perim eter Fram ing & C aulking 32 36
Fire R ated C ontrol Joints 37 38
Access & Air Penetrations 39
Electrical Penetrations 40 41
Plum bing Penetrations 42
B eam Encasem ent System s Fire R ated 43 44
Panel Ceiling Systems
Introduction & Product R ange 45 49
D esign C onsiderations 50
G rid Installation 50 52
Panel Installation 52
B ulkheads & R aked C eilings 53
H ealth & Safety 56
G yprock G uarantee 56
C ontact D etails 56
Introduction
C SR G yprock has developed a w ide range of decorative
ceiling system s as w ell as a large selection of fire and/or
acoustic rated ceiling system s to m eet specific FR L (Fire
R esistance Level), R w (W eighted Sound R eduction Index)
and Sound Absorption requirem ents.
C SR G yprock offers both Flush Jointed C eiling System s and
Panel C eiling System s.
Flush J ointed Ceiling Systems
G yprock

Flush Jointed C eiling System s utilise G yprock


plasterboard sheet w hich is fixed to appropriately prepared
fram ing. P lasterboard joints are taped and setto form
a sm ooth flush jointedcontinuous ceiling suitable for
painting.
G yprock

Flush Jointed C eiling S ystem s are suitable


for virtually all interior dom estic and com m ercial ceiling
applications and can be installed under roof or floor fram ing.
W here a level of finish is specified, refer to AS2589.1 for
additional fram ing and fixing requirem ents.
Specific ceiling system s are available for decorative, acoustic
and fire rated applications. Advantages include:
Flush jointing gives a sm ooth, seam less, easily decorated
finish.
System s available for decorative, acoustic rated and fire
rated application.
S uitable for use under a w ide range of roof and floor
structures.
Perm it flexible location of internal non-loadbearing w alls.
Surface or flush m ounted light fittings can be used.
Fire rated ceilings provide protection for services m ounted
above the ceiling, and can accom m odate air conditioning
ducts and dam pers, bulkheads and access panels.
Panel Ceiling Systems
Panel C eiling System s com prise G yprock

Plasterboard
C eiling Panels, C SR Ecophon Panels, U SG C eiling Panels or
C SR Fricker C eiling Tiles. These panels are generally placed
in a tw o-w ay grid w hich is suspended below floor or roof
fram ing. Ecophon panels are also available to fix directly to
battens or existing plasterboard ceilings.
G yprock Plasterboard C eiling Panels have a plasterboard
core, and are used as decorative linings in com m ercial
applications. They can also be used in system s to reduce
the transfer of noise over partitions.
U SG C eiling Panels Panels have a m ineral fibre core w hich
provides m oderate to high levels of acoustic absorption.
They are available in a variety of surface textures and edge
details.
C S R Ecophon

P anels have a glassw ool core, and are


used w here high levels of acoustic absorption are required.
They are available in a variety of edge details for exposed,
concealed or sem i-concealed support grids.
P anel ceiling system s are suitable for non fire rated
applications only. System s detailed in this guide are non-
trafficable, although a trafficable ceiling is available from
R ondo B uilding Services.
Gyprock

Ceiling Systems Installation Guide


3
Overview of Flush J ointed Ceiling Systems
Overview of Panel Ceiling Systems
Plasterboard adhesive and/or fastener
fixed directly to timber/steel floor/
ceiling joists
Plasterboard screw fixed to steel
furring channel attached with
appropriate fixing clips to timber/steel
floor/ceiling joists
Plasterboard screw fixed to resilient
mounted furring channel or resilient
furring under timber/steel floor/ceiling
joists
Plasterboard screw fixed to suspended
concealed metal grid (without resilient
mounts) under floor/ceiling joists
Square edge Shiplap edge Tegular edge
Existing sheet
ceiling
Ecophon
Panel
Shiplap F
Plasterboard screw fixed to suspended
concealed metal grid (with resilient
mounts) under floor/ceiling joists
G yprock

Flush Jointed C eiling


S ystem s utilise various fram ing
form ats and plasterboard fixing
techniques. G yprock

plasterboard
w hich is fixed to the underside of
the fram ing is jointed using tape
and com pounds to C S R G yprock
specifications to form sm ooth ceiling
surfaces for decorative coating.
Plasterboard screw fixed above and
below Lipped Steel C-Stud
Plasterboard screw fixed below Lipped
Steel C-Stud
G yprock Panel C eiling System s offer lightw eight, decorative and/or acoustic solutions for com m ercial applications. They are
installed w ith a tw o-w ay suspended grid or direct fixed to battens or an existing plasterboard ceiling.
The precoated face of the supporting grid or edge profile of the panels com bine w ith various surface textures to form a decorative
feature ceiling.
Kerfed edge
Gyprock

Ceiling Systems Installation Guide


4
Components
Plasterboard
C SR G FC m anufactures and supplies a diverse range of
plasterboard and fibre cem ent sheets, acoustic panels
and accessories to suit a m ultitude of w all, ceiling and
encasem ent applications.
Gyprock

Plasterboard CD is com posed of a gypsum


core encased in a heavy duty linerboard. Available w ith
long edges recessed to assist in producing a sm ooth, even
and continuous surface once jointed, or in square edge
(SE) and recessed edge/square edge (R E/SE). G yprock


Plasterboard C D is m anufactured to AS2588 G ypsum
P lasterboard, and incorporates C D (C ontrolled D ensity)
technology. G yprock Plasterboard C D is suitable for internal
w alls and ceilings.
Gyprock Supaceil

is a 10m m thick sheet designed


to span up to 600m m in ceiling applications. G yprock
S upaceil is com posed of a gypsum core encased in a
heavy duty linerboard. Long edges are recessed for flush
jointing. G yprock S upaceil is m anufactured to A S 2588
G ypsum Plasterboard, and incorporates C D (C ontrolled
D ensity) technology.
Gyprock Soundchek

has been designed to provide


increased acoustic resistance in w all and ceiling system s.
G yprock S oundchek

is com posed of a high density


gypsum core encased in a heavy duty linerboard. Long
edges are recessed to assist in producing a sm ooth, even
and continuous surface once jointed. G yprock Soundchek
is m anufactured to AS2588 G ypsum Plasterboard, and is
suitable for internal w alls and ceilings.
Gyprock Impactchek

is high strength plasterboard


designed for im pact areas. It is com posed of a glass fibre
reinforced gypsum core plus a fibreglass m esh bonded to the
inside of the back face. 13m m IM PAC TC H EK is encased in a
violet linerboard and m ay be used in fire rated applications,
and 10m m IM PAC TC H EK is encased in w hite linerboard. The
long edges of both are recessed for flush jointing.
Gyprock Aquachek

is designed for use in lining the w alls


of w et areasof residential and com m ercial buildings. It is a
gypsum plasterboard w ith a core treated to m ake it resistant
to m oisture and hum idity. It is m anufactured to satisfy the
requirem ents of AS2588 G ypsum Plasterboard, and the
w ater resistant requirem ents of ASTM C 630. It is encased
w ith light blue linerboard and the long edges are recessed.
Gyprock Fyrchek

can be used in w all and ceiling


system s w here an FR L is to be achieved, or w here acoustic
perform ance is required. G yprock Fyrchek

is com posed
of a specially processed glass fibre reinforced gypsum core
encased in a heavy duty pink liner board.
Gyprock Fyrchek MR

is prim arily intended for w alls and


ceilings in w et area room sand for soffits and external w alls
that m ust achieve fire resistance. G yprock Fyrchek M R

is
com posed of a specially processed glass fibre reinforced
gypsum core w hich is treated in m anufacture to w ithstand
the effects of m oisture, and encased in a heavy duty light
blue liner board.
Gyprock Flamechek MR

is a fire and m oisture resistant


high perform ance 10m m thick plasterboard. G yprock
Flam echekM R

is a gypsum plasterboard w ith a treated core


to m ake it resistant to m oisture and fire. It is m anufactured to
satisfy the requirem ents of AS2588 G ypsum Plasterboard,
and the w ater resistant requirem ents of A S TM C 630. It
is encased w ith blue linerboard and the long edges are
recessed.
Gyprock

Shaft Liner Panel is a 25m m thick sheet


com posed of a glass fibre reinforced gypsum core encased
in a heavy duty linerboard. G yprock S haft Liner P anel is
used to enclose lift shafts, stairw ells and service shafts in
m ultistorey construction. G yprock Shaft Liner Panel can be
used to achieve fire resistance in w all and ceiling system s.
Gyprock

Flexible Plasterboard has been designed


for curved w all and ceiling system s and has an enhanced
core to enable bending to a sm all radius. It is com posed of
a gypsum core encased in a heavy duty linerboard. Long
edges are recessed to assist in producing a sm ooth, even
and continuous surface once jointed. G yprock

Flexible
Plasterboard is 6.5m m thick and is installed in tw o layers.
Gyprock

Perforated Plasterboard has been designed


for use in ceilings w here additional sound absorption is
required. It is com posed of a gypsum core encased in a
heavy duty linerboard and incorporates C D technology. Long
edges are recessed for flush jointing. Perforations total 8.2%
of the sheet area.
1
2
0
0
m
m

3600mm
FIG 1: PERFORATION PATTERN
Flush J ointed Ceiling Systems
Gyprock

Ceiling Systems Installation Guide


5
TABLE 1: FIRE HAZARD PROPERTIES
C SR G FC Product SM O G R AR C
G roup
N um ber
10 13m m Plasterboard C D 0 1
10m m SU PAC EIL

0 1
10 - 13m m SO U N D C H EK

0 1
10 13m m AQ U AC H EK 0 1
6.5m m FLEXIB LE 0 1
13m m Perforated Sheet 0 1
13 16m m FYR C H EK

0 1
13 16m m FYR C H EK M R

0 1
25m m SH AFT LIN ER PAN EL 0 1
10m m FLAM EC H EK M R

0 1
N O TES: SM O G R AR C = Sm oke G row th R ate Index.
Fire Hazard Properties
The B C A lim its the m aterials used in C lass 2 to 9 buildings
by controlling the Fire H azard properties of linings. These
properties are assessed using AS/ISO 9705 room burn test
or AS/N ZS3837 the cone calorim eter test. The room burn
test is a large scale test to determ ine SM O G R AR C , and the
cone calorim eter is a sm all scale test to determ ine a G roup
N um ber.
GYPROCK


COVE CORNICE
GYPROCK


J AZZ CORNICE
GYPROCK


TEMPO CORNICE
GYPROCK


CLASSIC CORNICE
GYPROCK


SYMPHONY CORNICE
GYPROCK


CONCERTO CORNICE
Gyprock

Cornice
C S R G yprock m anufactures six popular m achine m ade
cornice profiles w hich cater for m any styles and applications.
P lease refer to P roduct Availability table in this section
for detailed product size and availability inform ation. It is
recom m ended that cornice be attached w ith G yprock


C ornice C em ent.
GYPROCK

SHADOWSET
FLUSH
GYPROCK

SHADOWSET
PLANT-ON
1
2
0
0
m
m

1
0
5
0
m
m
Overall 3600mm
450mm
75mm
nom.
150mm 450mm
FIG 2: GYPROCK PERFORATED PLASTERBOARD
DIMENSIONS
Gyprock

Ceiling Systems Installation Guide


6
TABLE 2: GYPROCK

PRODUCT AVAILABILITY
C olour shading behind each product approxim ates the colour of the product face liner sheets.
G yprock Product
Thickness
m m
W idth
m m
Sheet Length (m m ) M ass
kg/m
2 2400 2700 3000 3600 4200 4800 5400 6000
C D R EC ESSED ED G E
10
1200 W W W W W W W W
6.5
1350 W W W W W W
13
900 *W SN W W
8.5 1200 SN W SN W SN
1350 SN W
C D SQ U AR E ED G E
10 1200 W SN W SN W 6.5
13 1200 SN SN 8.5
C D R EC ESSED ED G E/
SQ U AR E ED G E
10
1200 W
6.5 1210 W
1350
SU PAC EIL

10
900 W W W W
7.2 1200 SN W
1350 W
SO U N D C H EK

10 1350 9.3
13 1200 13.0
AQ U AC H EK

10
1200 SN
8.0
1350 SN SN W SN SN W SN
13 1200 W W 10.4
IM PAC TC H EK

10 1350 6.5
13 1200 10.3
FLEXIB LE 6.5 1200 4.25
FLAM EC H EK M R

10 1350 8.0
FYR C H EK

13 1200 W 10.5
16 1200 SN W 12.5
FYR C H EK

M R
13 1200 W SN SN 10.7
16 1200 W SN W SN 13.5
PER FO R ATED SH EET

13 1200 10.0
SH AFT LIN ER PAN EL 25 600 19.8
C O VE C O R N IC E
55 0.7kg/m
75 W W N T 0.9kg/m
90 1.3kg/m
C LASSIC

C O R N IC E 90 1.2kg/m
TEM PO

C O R N IC E 90 1.8kg/m
SYM PH O N Y

C O R N IC E 75 0.9kg/m
C O N C ER TO

C O R N IC E 90 1.6kg/m
JAZZ

C O R N IC E 75 1.8kg/m
SH AD O W SET

105 1.0kg/m
Indicates available in: = All States & Territories; W = W estern Aust.; S = South Aust.; N = N orthern Territory.
Indicates N O T available in: W = W estern Aust.; S = South Aust.; N = N orthern Territory.
* = Length is 2740. = 3300 and 3900m m lengths also available in W A only.
In W estern Australia only, additional R ecessed Edge/Square Edge products are available.
Additional sizes m ay be available in som e products. C all your state office for details.
Gyprock

Plasterboard & Cornice Availability


Gyprock

Ceiling Systems Installation Guide


7
Stud Adhesive
G yprock

Acrylic Stud Adhesive is coloured blue for easy


identification. It can be used on both tim ber and steel in
tem peratures not less than 5C .
C ontact surfaces m ust be free of oil, grease or other foreign
m aterials before application. The adhesive is applied w ith a
broad knife to form 25m m diam eter by 15m m high w alnuts.
T his p ro d uct
is suitable for
use w ith pre-
painted m etal
b a tte n s a n d
som e treated
tim bers. Alw ays
follow directions
on packaging
w h e n u s in g
C S R s tu d
adhesive.
Fasteners
C S R G yprock distributes a com prehensive range of ring
shank nails, hot-dip galvanised clouts, and screw s for
use w ith tim ber and steel fram ing to accom m odate m ost
installation applications.
Gyprock

Resilient Mount
The G yprock

R esilient M ount is a proprietary com ponent


used in conjunction w ith R ondo steel sections for fastening
G y p r o c k


plasterboard to a
supporting structure
w hile sim ultaneously
iso lating it fro m
stru ctu re b o rn e
vibration.
This significantly
re d u c e s th e
am ount of im pact
noise, speech and
lo w freq uency
so und filtering
through to room s
a b o ve , b e lo w
o r a lo n g s id e
t h e n o is e
g enerating ro o m . T he resilient m o unt has b een
d esig n fo r use o n ceiling s and can b e used o n
w alls provided plasterboard w ith m inim um m ass of
13kg/m
2
is fixed on the resilient m ount side of the w all. The
m ount can be used in fire rated and non fire rated system s.
G yprock

R ing Shanked N ails.


2.8m m dia. for fixing to tim ber.
G yprock

C louts.
2.8, 3.15 and 3.75m m
dia. (hot-dip galvanised) for fixing to tim ber.
G yprock

Type W Screw s.
#6 and #8 for fixing to
tim ber.
G yprock

Type SN eedle Point (N P) Screw s.


#6 and #8 for fixing to
tim ber, and for lightw eight
steel studs and furring channel up to 0.8m m thickness.
G yprock

Type SD rill Point (D P) Screw s.


#6 and #8 for fixing to
steel fram ing 0.8m m to
1.2m m thickness.
G yprock

Plasterboard Lam inating Screw s.


#10 x 40m m . for
lam inating layers of
plasterboard together (w here perm itted).
Fasteners for Plasterboard Fixing:
WARNING
Stud adhesive M U ST N O T be relied on in FIR E R ATED
system s.
D aubs of adhesive m ust never coincide w ith fastener
points.
Stud adhesive does not constitute a fixing system on its
ow n and it m ust be used in conjunction w ith nail or screw
fasteners.
4
0
m
m

(
N

1
2
9
)
2
8
m
m

(
N

3
0
8
)
2
0
m
m
24mm
4.5mm
Furring Channel
N129 or N308
Gyprock
Resilient
Mount
GYPROCK Plasterboard
J ointing & Finishing
C SR G yprock has a w ide range com pounds, cem ents and
accessories for finishing plasterboard installations.
This m anual does not provide plasterboard jointing and
finishing details.
It should be noted that m ulti-layered system s only require
jointing and finishing of the outer layer.
Inform ation relating to the jointing and finishing of G yprock
plasterboard can be found in the G yprock

Plasterboard
Installation M anual, N G YP547, or visit the G yprock

W eb
site w w w .gyprock.com .au
Gyprock

Ceiling Systems Installation Guide


8
Handling &
Storage
All m aterials m ust be kept dry, preferably stored inside. C are
should be taken to avoid sagging or dam age to ends, edges
and surfaces of sheets.
All G YPR O C K plasterboard m ust be stacked flat, properly
supported on a level platform or on support m em bers w hich
extend the full w idth of the sheets and w hich are spaced at
a m axim um of 600m m centres.
If stored outside, sheets m ust be stored off the ground,
stacked as previously detailed and protected from the
w eather.
Support full width of Gyprock


plasterboard sheets
600mm
maximum
STACKING AND SUPPORT
OF PLASTERBOARD SHEETS
Gyprock

Mastic & Sealants


G yprock

Fire M astic m ust be used in fire rated system s


w here caulking is indicated and is also recom m ended
for caulking acoustic system s. It is available in 600m l
sausages.
G yprock

W et Area Acrylic Sealant is recom m ended for


sealing non fire rated w et area system s. It is available in
300m l cartridges.
Verm iculite m ixed w ith plaster is used in som e ceiling junction
details. It is available in 6kg bags. R efer C aulking in the
Plasterboard Fixing section for lim itations.
Steel Framing Components
C S R G yprock recom m ends steel building elem ents
m anufactured by R ondo B uilding Services Pty Ltd, for our
system s. O ther brands of equivalent or better perform ance
m ay be used. It is the responsibility of the m anufacturer of
the steel com ponent to substantiate equivalent or better
perform ance than the recom m ended R ondo com ponent.
G eneral inform ation on R ondo steel building com ponents is
provided throughout this m anual.
A dditional inform ation can be obtained from the R ondo
B uilding Services Pty Ltd office in your state, or telephone
1300 367 663.
LIGHTS
R ecessed lights m ust be installed so as to prevent dam age
from tem perature rise and to prevent the risk of fire. R efer
to AS/N ZS 3000.
Gyprock

Ceiling Systems Installation Guide


9
Framing
Introduction
Fram ing requirem ents detailed in this guide apply to both non
fire rated and fire rated installations.
This m anual d etails the m inim um requirem ents for
various com m on tim ber and steel fram ing system s, and
recom m ended installation m ethods.
Fram ing m ust com ply w ith the appropriate requirem ents
detailed in this guide and additional requirem ents detailed in
C SR G yprock or R ondo B uilding Services literature current
at the tim e of installation.
Timber Framing
Tim ber m em bers to w hich plasterboard w ill be fixed
m ust:
m ust com ply w ith AS1684 R esidential Tim ber-Fram ed
C onstructionor AS1720.1 Tim ber Structures : D esign
M ethods.
be spaced at no m ore than 600m m centres.
have a m inim um fixing face w idth of 35m m .
have a tim ber m oisture content at the tim e of lining of no
m ore than 16% .
U nseasoned tim ber fram ing shall be given sufficient drying
tim e in the construction program m e to m inim ise the
possibility of shrinkage after the fixing of linings.
Kiln-dried tim ber fram ing m ust be protected from w etting
during storage and erection.
C C A or LO SP treated tim ber classified H 1 to H 3 m ay be
used subject to specific plasterboard fixing requirem ents.
R efer to Plasterboard Fixingsection.
Steel Framing
Steel fram ing to w hich plasterboard w ill be fixed m ust:
com ply w ith A S /N ZS 4600, C old Form ed S teel
Structures.
be spaced at no m ore than 600m m centres.
have a m inim um fixing face w idth of 32m m .
be no greater than 1.2m m base m etal thickness.
Ceiling Suspension Systems
G yprock

C eiling Suspension System s are designed to


AS2785 Suspended C eilings D esign and Installation.
They are not trafficable unless stated, and are designed
to carry the w eight of the ceiling only.
W here a trafficable ceiling is required, install a proprietary
trafficable ceiling system such as R ondo W alkabout.
Strengthen suspension system s to support light fittings and
access panels as detailed in the appropriate illustrations in
this guide and/or other relevant C SR G yprock or R ondo
technical literature.
Any additional loads are not to be placed upon, or carried
by the suspension system .
Corrosion Protection
For steel com ponents in external environm ents, in heavy
industrial areas or w ithin 1km of the coast, additional
coatings m ay b e req uired . R efer to A S 2785 for
guidance.
Control J oints
C ontrol joints are to be installed in both fire rated and non-
fire rated ceilings:
To coincide w ith control joints in the supporting fram e.
In continuous interior ceiling areas, spaced at no m ore
than 12m centres in both directions. C ontrol joints m ay
be positioned to intersect light fixtures, heating vents and
air diffusers.
In exterior ceilings, spaced at not m ore then 6.0m
m axim um centres in both directions.
At changes of fram ing type.
The continuity of G yprock

plasterboard and support


fram ew ork should be broken at control joints.
R efer to the follow ing details and the additional details on fire
rated control joints later in this guide.
FIRE RATED NON FIRE RATED
15 to 20mm gap
RONDO P35
Control Joint
with set finish
Furring Channel
Furring Channel
Joiner N138
FIG 3: CONTROL J OINT DETAILS FOR NON FIRE RATED
CEILING
15 to 20mm gap
Furring
Channel
50mm max.
RONDO P35
Control Joint
with set finish
GYPROCK
plasterboard
screw fixed to
furring channel
each side of
joint at 200mm
max. centres
FIG 4: CONTROL J OINT DETAILS FOR NON FIRE RATED
CEILING
Gyprock

Ceiling Systems Installation Guide


10
TABLE 4: MAXIMUM SPANS FOR METAL BATTEN/FURRING CHANNEL USED IN CEILINGS
G yprock Plasterboard
Layers x Thickness
N 581*
R esilient Furring
N 308*
Furring C hannel
N 129*
Furring C hannel
Spacing of Furring Spacing of Furring Spacing of Furring
450 600 450 600 450 600
M axim um Perm issible Spans for M etal B atten/Furring
1 x 10m m all products
except C D and SO U N D C H EK
600 600 1000 900 1550 1400
1 x 10m m G yprock C D 600 1000 1550
1 x 10m m SO U N D C H EK
1 x 13m m all products
600 600 1100 1000 1550 1400
1 x 16m m FYR C H EK 600 600 1100 1050 1550 1400
2 x 13/16m m FYR C H EK 600 600 1100 900 1400 1300
3 x 16 FYR C H EK 900 800 1300 1200
N O TE: Furring to be continuous over 2 or m ore spans. D ead load deflection Span360. * Includes Internal U D L of 0.25kPa.
TABLE 3: MAXIMUM SPAN OF PLASTERBOARD IN CEILING APPLICATIONS
G YPR O C K Product
Thickness
M axim um Spacing of Fram ing M em bers
G eneral Applications
Areas of H igh H um idity and
External Areas
(m m ) (m m )
6.5m m Flexible Plasterboard used in tw o layers 350 N A
10m m G YPR O C K Plasterboard C D 450 N A
10m m All types of plasterboard except C D 600 450
13m m plasterboard all types except Perforated 600 450
13m m Perforated Sheet 600 N A
16m m FYR C H EK 600 450
N O TE: N A = N ot Applicable
200mm max.
Top Cross Rail
Furring channel
Fix Wall Angle Trim to
wall with fasteners at
600mm max. centres
6mm gap max.
FIG 5: PERIMETER DETAIL FOR NON FIRE RATED
CEILINGS
FIG 6: PERIMETER DETAIL FOR NON FIRE RATED
CEILINGS
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


11
Steel Furring Channel
Direct Fixed to Framing
G YPR O C K plasterboard m ay be fixed directly to steel
furring w hich is held by appropriate direct fixing clips
attached to a structural support as show n in adjoining
details.
D irect fixing clips provide som e vertical adjustm ent to
enable accurate levelling of the furring. After levelling,
the brackets should be perm anently fixed in place by
tw o nails/screw s.
Furring channels then snap fit into the clips.
The ceiling drop should be lim ited to 200m m m axim um
w ith these attachm ent system s.
Install brackets to ensure there is a clearance betw een
joist and furring of 10m m m inim um .
A system com prising N 129 furring channel spaced
at 600m m centres and w ith fixing clips at 1200m m
m axim um centres can support a m axim um of 3
layers x 16m m G YPR O C K FYR C H EK and lightw eight
insulation.
R efer to span tables in this guide and R ondo B uilding
Services specifications for alternative grid span and
spacing inform ation.
Refer to chosen perimeter
detail for appropriate
positioning of first and last
furring channel
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)
End of furring channels 10mm
clear of wall face Direct Fixing Clips at
appropriate spacing to
suit permissable span
of furring channel
F
u
rrin
g
C
h
a
n
n
e
l S
p
a
c
in
g

(6
0
0
m
m
m
a
x
im
u
m
c
e
n
tre
s
)
Timber, Steel or Concrete
support structure
Direct Fixing Clips fixed
to support framing at
appropriate spacing to
suit permissable span
of furring channel
N553 Angle or N140/142Track
fixed to wall at ends and
600mm max. centres between
F
u
rrin
g
C
h
a
n
n
e
l S
p
a
n

FIG 8: STEEL FURRING CHANNEL DIRECT FIXED TO FRAMING
N226 Clip
fixed to joist
Furring Channel
N129/308
Joist
Fix with
2 x 40mm
nails
16mm (N308)
28mm (N129)
N394 Clip
fixed to joist
Furring Channel
N129/308
Joist
Fix with
2 screws
Furring
Channel
N129/308
Masonry anchor and
clip assembly N150
or A239
FIG 7: STEEL FURRING CHANNEL DIRECT FIXING METHODS
Furring
Channel
N129/308
Rondo
BETA-FIX Clip
fixed with
masonry
anchor to
project
specifications
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


12
Steel Furring Channel on
Resilient Mounts
The G yprock R esilient M ount m ay be screw fixed directly to
the underside of joists or trusses using (50m m x N 8 screw s
for tim ber) or (30m m x N 8 screw s for steel) as detailed in
FIG 8.
Should the joists or trusses be uneven, the adjustable direct-
fix bracket (N C S R 4) should be fixed to the side of the
fram ing. This w ill provide up to 20m m height adjustm ent
for levelling purposes. After levelling, the bracket should be
perm anently fixed in place w ith tw o nails/screw s.
The resilient m ount m ay then be screw fixed to the adjustable
bracket (N C SR 4) using a 45m m x N 8 screw .
The furring channels then snap fit into the anchor clips.
The G yprock

R esilient M ount is designed to support a


m axim um ceiling load of 27kg per m ount, and m ust be
installed at appropriate centres to suit the chosen ceiling
system and total ceiling m ass.
A system com prising N 129 furring channel spaced at
600m m centres fitted w ith G yprock

R esilient M ounts
at 1200m m centres m axim um along the furring channel,
can support a m axim um of 3 layers x 16m m G YP R O C K
FYR C H EK and lightw eight insulation.
End of furring channels 10mm
clear of wall face
Gyprock Resilient Mounts at
appropriate centres to suit
chosen system
F
u
rrin
g
C
h
a
n
n
e
l S
p
a
c
in
g

(6
0
0
m
m
m
a
x
im
u
m
c
e
n
tre
s
)
Timber or Steel
support structure
F
u
r
r
in
g
C
h
a
n
n
e
l S
p
a
n

Refer to chosen perimeter
detail for appropriate
positioning of first and last
furring channel
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)
N553 Angle or N140 /142Track
fixed to wall at ends and 600mm
max. centres between
FIG 10: STEEL FURRING CHANNEL FIXED WITH RESILIENT MOUNTS TO FRAMING
FIG 9: GYPROCK RESILIENT MOUNT FIXING
Adjustable Direct Fix
Bracket NCSR4
(when required)
GYPROCK
Resilient Mount
Furring Channel
N129/308
GYPROCK
FYRCHEK
Plasterboard
(max. 3 layers
x 16mm)
GYPROCK
Mounting Screw
R efer to span tables in this guide and R ondo B uilding
Services specifications for alternative grid span and spacing
inform ation.
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


13
Concealed Grid Suspended Ceiling
G YPR O C K plasterboard m ay be fixed directly to steel furring
w hich is part of a concealed grid suspended ceiling fram e as
detailed in the follow ing illustration.
These system s are N O N -TR AFFIC AB LE and are not designed
to resist the w eight of foot traffic. W here access to the ceiling
area is required, install a R ondo W alkabout C eiling System .
G yprock Suspended C eiling System s com prise suspension
brackets fixed to the supporting structure, suspension
rods, suspension clips, top cross rails, and a locking key or
G yprock R esilient M ount for coupling to the furring channel.
R efer to Suspended C eiling C om ponents.
W here Top C ross R ails are not continuous, they m ust be
joined as show n in the suspended ceiling com ponents
details. Joins m ust be aligned w ith hanging points.
W here Furring C hannels are not continuous, they m ust
be joined as show n in the suspended ceiling com ponents
details.
End of furring channels
10mm clear of wall
First and last Top
Cross Rail 200mm
max. from wall
Timber, Steel or
Concrete support
structure
T
o
p
C
ro
s
s
R
a
il S
p
a
n

F
u
rrin
g
C
h
a
n
n
e
l S
p
a
cin
g

F
u
r
r
in
g

C
h
a
n
n
e
l
S
p
a
n

Refer to chosen perimeter
detail for appropriate
positioning of first and last
furring channel
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)
N553 Angle or N140/142Track
fixed to wall at ends and 600mm
max. centres between
1
5
0
m
m

n
o
m
i
n
a
l

m
i
n
.
FIG 11: CONCEALED GRID SUSPENDED CEILING
W here the G yprock R esilient M ount is used, it is designed
to support a m axim um ceiling load of 27kg per m ount, and
m ust be installed at appropriate spacing to suit the chosen
ceiling system and total ceiling m ass.
A system com prising N 128 Top C ross R ails at 1200m m
m axim um spacings, suspension points at 1200m m m axim um
centres, N 129 furring channel at 600m m m axim um spacings
(w ith or w ithout G yprock

R esilient M ounts) can support up


to 3 layers of 16m m G YPR O C K FYR C H EK and lightw eight
insulation.
N o provision has been m ade for the support of services
or lighting system s. A dequate independent or additional
support m ust be provided for services and lighting system s.
R efer to G rid Installation in this guide and R ondo B uilding
Services specifications.
R efer to span tables in this guide and R ondo B uilding
Services specifications for alternative grid span and spacing
inform ation.
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


14
Suspension
Rod
N122/123
Suspension
Clip N124
Top Cross
Rail
N127/128
Suspension
Rod N121
Suspension
Clip N2534
Top Cross
Rail
N127/128
Joist
Suspension
Rod N121/122
Suspension
Rod Bracket
N534
Joist
Suspension
Rod N121/122
Suspension
Rod Bracket
N534
Top Cross Rail
N127/128
Locking Key
N139
Furring Channel
N129/308
Top Cross Rail
N127/128
Resilient Mount to
Top Cross Rail
Clip NCSR5
Gyprock
Resilient
Mount
Furring Channel
N129/308
Gyprock Screw
N6 x 30mm
SUSPENSION BRACKETS
SUSPENSION CLIPS
J OINERS
Fixing Clip Assembly
N151 or NA124
Joiner N138
Furring Channel
N129/308
Allow 20mm expansion
gap for every 6m of
furring channel in fire
rated ceilings
Top Cross Rail
Joiner N272
(or 200mm min.
length of Top
Cross Rail)
Top Cross Rail
N127/128
Allow 20mm
expansion gap
for every 4.8m of
TCR in fire rated
ceilings
J OINERS
Key-Lock

Concealed Grid Suspended Ceiling Components


(Refer to Rondo Building Services literature for additional information)
FIRE RATED NON FIRE RATED
Appropriate
masonry fastener
Suspension
Rod
N121/122
Suspension
Rod Angle
Bracket
N547
Gyprock

Ceiling Systems Installation Guide


15
Suspended Bulkheads
Drops up to 450mm up to 3 layers x 16mm GYPROCK Plasterboard
Drops 450mm to 1200mm up to 1 layer GYPROCK Plasterboard (8.5kg/m
2
maximum).
FIG 14: BULKHEAD DETAIL
Drops greater than 450mm up to 3 layers x 16mm
GYPROCK Plasterboard
1500mm
max.
3
0
0
m
m

m
a
x
.
Bracing may
require noggings
Independent
suspension of
ceilings
Wall Track N140 (to
support ends of Furring
Channel) fixed to
framing at 600mm max.
centres
Bracing fixed to
structural
soffit/purlins
Framing fixed to
structural soffit/purlins
Track fixed to
bottom of studs
Bulkheads
B ulkheads require independent support to carry
the additional plasterboard and fram ing m em bers.
D epending on the drop and plasterboard m ass to
be installed, this m ay be achieved w ith additional
suspension hangers as detailed in FIG 12 and 13, or
by fixing fram ing m em bers directly to the structural
supports as detail in FIG 14.
A ll bulkheads require bracing to provide lateral
stability to the fram ew ork during incidental loading.
This m ay be achieved by providing stud bracing, fixed
diagonally betw een the bulkhead fram ew ork and the
structural soffit at regular intervals as show n in FIG 14
or alternatively, by rigidly coupling the ceiling to the
bulkhead. If rigid coupling is used, the ceiling m ust
be checked for horizontal loading. R efer to R ondo
B uilding Services for assistance.
25mm
Notch furring channel
(leaving head flange)
bend and screw fix
Cut and remove
25mm of head
Cut through head and
down legs of furring
channel (leave face intact)
bend and screw fix
GYPROCK
plasterboard
TCR Suspension
Clip N2534
Top Cross Rail
(N128 for fire
rated systems}
Locking Key
N139
Furring Channel
N129
D
r
o
p
Suspension Rods
fixed to structural
support
FIG 12:
GYPROCK
plasterboard
TCR Suspension
Clip N2534
Top Cross Rail
(N128 for fire
rated systems)
Gal.
Angle
Locking Key
N139
Furring Channel
N129
Gyprock Edge Profile
Quad Corner Step
Screw each
side to lock key
to top cross rail
D
r
o
p
Alternative plasterboard
corner detail for fire
rated systems
Suspension Rods
fixed to structural
support
FIG 13:
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


16
Bracing as
and where
required
Screw to fix N139
Locking Key to Top
Cross Rail
Screw to prevent
clips sliding up Top
Cross Rail
FIG 17: RAKED SUSPENDED FLUSH J OINTED CEILING
Raked Suspended Ceilings
Rondo Curved
Top Cross Rail
Bulkhead
detail as
required
FIG 15: CURVED CEILING FRAMING
Curved Ceilings
G YPR O C K plasterboards m ay be used on curved installations
in accordance w ith Table 5 and 6.
W here a radius tighter than 900m m is to be used, the fram ing
should be sheeted w ith G YPR O C K Flexible Plasterboard.
For detailed fixing inform ation on G Y P R O C K Flexible
Plasterboard, refer to brochure N G YP544, G yprock Steel
Fram e W all System s Installation G uide.
Fire rated ceilings MUST NOT be curved to a radius of
less than 3000mm.
FIG 16: CURVED CEILING FRAMING
Curved Gyprock plasterboard
Ceiling Framing
Curved Furring Channel
TABLE 5: CURVING RADII AND MAXIMUM FRAME CENTRES FOR 6.5, 10, 13 AND 16MM GYPROCK PLASTERBOARDS
Plasterboard
Thickness
(m m )
G yprock
Flexible
Plasterboard
G yprock

Plasterboard C D and Flexible Plasterboard O N LY


All G yprock Plasterboards
except perforated
C urve R adius (m m )
<900 900 - 1000 1000 - 1500 1500 - 2000 2000 - 2500 2500 - 3000 3000 - 4000 4000 - Plus
M axim um Stud C entres (m m )
6.5
R efer to
Table 6
150 200 250 300 350 450 550
10 150 200 250 300 350 400 500
13 150 250 250 300 400 500
16 250 350
TABLE 6: MINIMUM CURVING RADII AND MAXIMUM FRAME SPACING FOR GYPROCK FLEXIBLE PLASTERBOARD
Applications
Sheets Installed Lengthw ays Sheets Installed W idthw ays
M inim um R adius M ax Stud Spacing M inim um R adius M ax Stud Spacing
C oncave 450m m 150m m 650m m 200m m
C onvex 250m m 125m m 450m m 200m m
N otes Low tem perature and hum idity w ill reduce board flexibility.
C urved Lengthw ays = w here recessed edges are N O T curved.
C urved W idthw ays = w here recessed edges are curved.
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


17
Rondo NB005
Batten
450mm
max.
Rondo Top Cross Rail and
Furring Channel Ceiling
Grid
FIG 18: BUTT J OINT CONSTRUCTION USING RONDO NB005 BATTENS (TOP VIEW)
Gyprock
plasterboard
Plasterboard fixed
with 2 screws each
side of joint
Recess formed with
Rondo NB005 Batten
Tape and set formed butt
joint as per normal Gyprock
recommendations for
recess joints
Butt J oints in Non Fire Rated Suspended Ceilings
FIG 18 show s suitable details for suspended ceilings in com m ercial buildings w hich are not required to be fire rated,
are isolated from building m ovem ent at the perim eter and have a w ell controlled air environm ent such as occupied, air
conditioned offices.
N ote: Install screw s to batten carefully.
C ollated screw guns m ay not be suitable.
N ote: Install screw s to batten carefully.
C ollated screw guns m ay not be suitable.
Rondo NB005
Batten
Battens at
300mm max.
centres
Rondo Top Cross
Rail and Furring
Channel Ceiling Grid
400mm
100mm
min.
400mm
Back-blocking
FIG 19: BUTT J OINT CONSTRUCTION USING RONDO NB005 BATTENS AND BACK-BLOCKING (TOP VIEW)
FIG 19 show s suitable details for suspended ceilings w here back-blocking is required.
NON FIRE RATED
Gyprock
plasterboard
Cornice
adhesive
Recess formed with
Rondo NB005 Batten
Plasterboard fixed
with 2 screws each
side of joint
Backblocking
Tape and set formed butt
joint as per normal Gyprock
recommendations for
recess joints
Gyprock

Ceiling Systems Installation Guide


18
Steel Frame
Ceiling Systems
Introduction
C SR G FC has developed a w ide range of tested fire and/
or acoustic ceiling system s utilising steel fram ing and
plasterboard fixed to one or both sides.
These system s are m ost com m only specified above stairw ells
and corridors, and under concrete floors w here personnel
access is not required.
This section also details m ethods for constructing isolated
bulkheads utilising steel furring channel fram ing.
Frame Requirements
R efer to the Fram ing section for the general requirem ents on
steel fram e construction.
All systems detailed in this section are non-trafficable,
and are designed to carry the weight of the ceiling only.
The ceiling framing must be strengthened to support
light fittings and services.
Ceilings Lined
One Side
J oist Selection
Steel joists for ceilings lined one side can be selected based
on Table 7, w hich provides span inform ation for R ondo
Lipped Steel Stud sections w hen used as ceiling joists.
J oist End Support
R efer to follow ing pages for alternative ceiling joist end
support configurations and recom m ended construction
m ethods.
Nogging/Bridging
W here joist span exceeds 2.50m , one row of nogging/
bridging is required at m id span.
W here joist span exceeds 4.00m , tw o row s of nogging/
bridging are required at equal spacings.
Control J oints
C ontrol joints are to be installed in both fire rated and non-fire
rated continuous interior ceiling areas, spaced at no m ore
than 12m centres in both directions, and as detailed in the
Fram ing section earlier in this guide.
Align ceiling joists with wall
studs (or provide heavier
gauge wall angle/track
support)
Bridging/Nogging (use
track, stud or nogging
section) fixed to joists
Fix wall track to structural
wall framing as detailed
FIG Z900: GENERAL LAYOUT OF CEILING FRAMING FOR SINGLE SPAN
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


19
50mm max.
Ceiling Joist held by friction fit in
track (0.75BMT Deflection Head
Track recommended)
NOTE: Friction joints are not
recommended where vibration or
mechanical equipment is used in
close proximity to the ceiling.
Fix track to studs or
masonry wall with 2 x
0.6kN fasteners at
600mm max. centres
Leave 5mm
maximum gap at
end of ceiling joist
for clearance
FIG Z901: J OIST END SUPPORT FRICTION J OINT
Maximum J oist Span: 2.0m (single span).
Maximum J oist Span: 2.8m (continuous over 2 or 3
spans).
Framing Installation
R efer to FIG Z901, Z902, Z903, Z904 and Z905 for alternative
fram e assem bly m ethods.
Install steel track w ith the low er flange aligned at the
required ceiling height and fix at ends and at 600m m
m axim um centres betw een.
To m asonry, use pow er driven fasteners, expansion
anchors, or easy drive m asonry anchors.
To steel stud fram ing, use G yprock type SScrew s, toggle
bolts or expandable fasteners.
To tim ber fram ing, use G yprock C louts or G yprock type
W Screw s.
C ut and install ceiling joists (lipped steel stud) into tracks,
leaving a 5 10m m gap at each end (8 15m m for
fire rated ceilings). Fix as indicated for the appropriate
installation m ethod.
N O TE: For alternative fram e construction m ethods or for
m ulti-span applications, refer to R ondo literature.
Plasterboard Installation
G Y P R O C K plasterboard can be installed in any of the
m ethods detailed in this guide w hich are appropriate for the
type of ceiling being constructed. R efer to appropriate details
on Plasterboard Fixing.
Caulking
Fire rated ceilings m ust have all perim eter gaps fully caulked.
R efer to Perim eter Fram ing & C aulking
TABLE 7: MAXIMUM SPAN OF J OISTS FOR INTERNAL CEILINGS
SINGLE SPAN LIPPED STEEL STUD LINED ONE SIDE
Uniform Distributed Load (UDL) = 0.25kPa.
C -Stud D epth m m 51 64 76 92 150
Stud G auge B M T (m m ) 0.50 0.50 0.75 1.15 0.55 0.75 1.15 0.55 0.75 1.15 0.75 1.15
Plasterboard (Layers x m m ) M axim um Span of Joist (m ) Joist Spacing 300m m
1 x 10 or 1 x 13 2.05 2.40 2.85 3.10 3.00 3.35 3.50 3.40 3.75 4.10 5.10 5.60
(2 x 16) or (1 x 13 + 1 x 16) 1.80 2.20 2.55 2.75 2.65 3.00 3.10 3.00 3.35 3.90 4.30 4.75
3 x 16 1.65 2.05 2.35 2.60 2.45 2.80 2.90 2.75 3.10 3.40 4.05 4.50
M axim um Span of Joist (m ) Joist Spacing 450m m
1 x 10 or 1 x 13 1.80 2.15 2.55 2.75 2.65 3.00 3.10 3.00 3.35 3.65 4.60 5.10
(2 x 16) or (1 x 13 + 1 x 16) 1.60 1.95 2.25 2.45 2.35 2.65 2.75 2.60 2.95 3.20 3.90 4.30
3 x 16 1.45 1.80 2.10 2.25 2.15 2.45 2.55 2.40 2.70 3.00 3.65 4.10
M axim um Span of Joist (m ) Joist Spacing 600m m
1 x 10 or 1 x 13 1.65 1.95 2.35 2.55 2.40 2.80 2.85 2.70 3.05 3.35 4.25 4.80
(2 x 16) or (1 x 13 + 1 x 16) 1.45 1.75 2.05 2.25 2.10 2.40 2.50 2.35 2.70 2.90 3.60 4.00
3 x 16 1.35 1.60 1.90 2.05 1.95 2.25 2.30 2.15 2.45 2.70 3.40 3.80
N O TES:
M axim um deflection = Span480 or 10m m .
N ogging/bridging required (equally spaced) 1 row for spans over 2.50m 2 row s for spans over 4.00m .
For alternative spans using boxed studs or m ultispan configurations, refer to R ondo B uilding Services.
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


20
50mm max.
Fix Ceiling Joists to wall track
with 1 x N8-18 x 16mm tek
screw top and bottom
Fix track to studs or
masonry wall with 2 x
0.6kN fasteners at
600mm max. centres
Wall
Stud
Track
FIG Z903: J OIST END SUPPORT MECHANICAL J OINT
Maximum J oist Span: 3.0m (single span).
Maximum J oist Span: 4.0m (continuous over 2 or 3 spans).
Fix Track N140/142 or 50 x 0.75BMT
Angle at ends and 600mm maximum
centres between
Furring Channel
N308/129 at 600mm
maximum centres
Fix Furring Channel
with 1 panhead
screw at each end
Angle 50 x 50
0.75mm BMT
6
0
0
m
m
m
a
x
.
SPAN
D
R
O
P
FIG Z910: BULKHEAD CONSTRUCTION
For Maximum SPAN and DROP data, refer to following table.
Angle Bracket and
fixings to engineer's
specifications
Fix joist to bracket
to engineer's
specifications
FIG Z904: J OIST END SUPPORT MECHANICAL J OINT
Maximum J oist Span: 6.0m (single span).
Fix joist to web of wall
stud to engineer's
specifications
NOTE: Wall stud size must
be checked for axial load
FIG Z905: J OIST END SUPPORT MECHANICAL J OINT
Maximum J oist Span: 6.0m (single span).
Wall
Stud
Track
Fix joist to track with
1 x N8-18 x 16mm tek
screw top and bottom
Loadbearing wall frame
(check for capacity)
Align joists
directly over
wall studs
FIG Z902: J OIST END SUPPORT MECHANICAL J OINT
Maximum J oist Span: 3.0m (single span).
Maximum J oist Span: 4.0m (continuous over 2 or 3 spans).
TABLE 8: BULKHEAD DROP & SPAN
Refer FIG Z910.
Plasterboard Lining
M axim um D rop & Span (m m )
Furring N 308 Furring N 129
1 x 10m m 680 1040
1 x 13m m 770 1080
2 x 16m m 710 1000
3 x 16m m 650 890
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


21
Ceilings Lined
Two Sides
J oist Selection
M axim um perm issible spans for R ondo Lipped Steel Stud
(150m m x 0.75B M T) lined on tw o sides are detailed in
Table 9.
M axim um perm issible spans for R ondo C -H Stud profiles
lined on tw o sides are detailed in Table 10.
Alternative steel fram ing m ethods are perm itted and m ust
be designed by the project engineer. Fram ing m ust be
at 600m m m axim um centres, w ith a m axim um m aterial
thickness of 1.2m m B M T.
J oist End Support
Refer to the follow ing details for alternative ceiling joist end support
configurations and recom m ended construction m ethods.
N ote the specific requirem ents for the end support construction
detailed w here the longer spans are chosen.
1.15m m B M T track and 1.5m m angle are non-standard and
m ay require fabrication.
FIG Z912: GENERAL LAYOUT OF LIPPED C-STUD CEILING FRAMING LINED TWO SIDES
Track or 2 x Angles (in accordance with span chosen from system table)
(1.15mm Track : use 2 x 0.6kN fixings at each joist).
(2 x 1.5mm Angles : use 2 x 1.0kN fixings at each joist).
2 or 3 layers 16mm
GYPROCK FYRCHEK
plasterboard
N10 panhead screw
0.55mm BMT
Track where all
joists are directly
over wall studs
N10 panhead
screw
Loadbearing Wall
Frame
Wall cladding to
required FRL
2 layers 16mm GYPROCK
FYRCHEK plasterboard
Lipped C Stud
Ceiling Joist
(single or boxed
refer system table)
Nogging
required where
ceiling joists
not boxed
10mm gap filled with
CSR Gyprock Fire Mastic
Gap at top of
wall lining to
be caulked to
appropriate
fire rating
10mm gap
filled with
CSR Gyprock
Fire Mastic
Nogging
O ne row of nogging is required m id-span w here single lipped
C -stud sections are used. N ogging is not required w here
boxed lipped C -stud sections are used.
N ogging m ust also be included at all joints in G YPR O C K
Shaft Liner Panel. R efer to FIG Z913.
Control J oints
C ontrol joints are to be installed in fire rated continuous
interior ceiling areas, spaced at no m ore than 12m centres
in both directions, and as detailed in the Fram ing section
earlier in this guide.
Plasterboard Installation
G YP R O C K plasterboard m ust be installed and fixed in
accordance w ith appropriate fire rated system details in this
guide. Layers applied to the top of the joists m ust be fixed to
fire rated 2 layer system specifications.
G YPR O C K Shaft Liner Panel should be installed into the C -H
Stud profile during fram e assem bly. C ut the panels 15m m
short, install and push hard-up one end. Install 22m m IB S
R od at the other end to seal the gap and allow for expansion.
R efer FIG Z913.
Caulking
Fire rated ceilings lined tw o sides m ust have perim eter gaps
fully caulked as detailed in FIG Z912 or Z913.
FIG Z913: GENERAL LAYOUT OF C-H STUD CEILING FRAMING LINED TWO SIDES
Track 1.15mm BMT.
Fixed to wall with 2 x 0.6kN
fixings at each joist
2 or 3 layers 16mm GYPROCK
FYRCHEK plasterboard
1 layer 25mm
GYPROCK Shaft
Liner Panel cut 15mm
short and pushed
hard-up one end
C-H profile nogging
required at joints in
Shaft Liner Panel only
C-H Stud Ceiling Joist
(size as per system
table) cut 15mm short
0.55mm BMT Track where
all joists are directly over
wall studs
N10 panhead screw
N10 panhead
screw
Loadbearing Wall
Frame
Wall cladding to
required FRL
10mm gap filled with
CSR Gyprock Fire Mastic
22mm Fyreguard
IBS Rod continuous
Gap at top of
wall lining to
be caulked to
appropriate
fire rating
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


22
TABLE 9: MAXIMUM SPAN OF CEILING J OISTS RONDO LIPPED C-STUD (150 X 0.75MM BMT) LINED TWO SIDES
System Plasterboard Linings Ceiling J oist Single Lipped C-Stud with 1 Row Nogging
CSR 992
Above: 2 x 16m m
G YPR O C K FYR C H EK
B elow : 2 x 16m m
G YPR O C K FYR C H EK
C eiling Joist Spacing (m m )
Allow able Span of Joist (m m )
End Support (FIG Z914)
1.15m m B M T Track
End Support (FIG Z915)
2 x 1.5m m B M T Angle
600 2000 3650
400 2600 4050
300 3200 4350
System Plasterboard Linings Ceiling J oist Boxed Lipped C-Studs with No Nogging
CSR 992
Above: 2 x 16m m
G YPR O C K FYR C H EK
B elow : 2 x 16m m
G YPR O C K FYR C H EK
C eiling Joist Spacing (m m )
Allow able Span of Joist (m m )
End Support (FIG Z914)
1.15m m B M T Track
End Support (FIG Z915)
2 x 1.5m m B M T Angle
600 2000 4350
400 2600 4750
300 3200 5100
System Plasterboard Linings Ceiling J oist Single Lipped C-Stud with 1 Row Nogging
CSR 993
Above: 2 x 16m m
G YPR O C K FYR C H EK
B elow : 3 x 16m m
G YPR O C K FYR C H EK
C eiling Joist Spacing (m m )
Allow able Span of Joist (m m )
End Support (FIG Z914)
1.15m m B M T Track
End Support (FIG Z915)
2 x 1.5m m B M T Angle
600 1800 3500
400 2300 3900
300 2700 4150
System Plasterboard Linings Ceiling J oist Boxed Lipped C-Studs with No Nogging
CSR 993
Above: 2 x 16m m
G YPR O C K FYR C H EK
B elow : 3 x 16m m
G YPR O C K FYR C H EK
C eiling Joist Spacing (m m )
Allow able Span of Joist (m m )
End Support (FIG Z914)
1.15m m B M T Track
End Support (FIG Z915)
2 x 1.5m m B M T Angle
600 1800 4150
400 2300 4600
300 2700 4900
TABLE 10: MAXIMUM SPAN OF CEILING J OISTS. RONDO C-H STUD PROFILE LINED TWO SIDES
System Plasterboard Linings Ceiling J oist C-H Profile
CSR 995
Above: 1 x 25m m
G YPR O C K Shaft Liner
B elow : 2 x 16m m
G YPR O C K FYR C H EK
C eiling Joist
Spacing (m m )
Allow able Span of Joist (m m )
C -H Profile D escription
64C H 55 102C H 55
600 1800 2600
300 2250 3250
System Plasterboard Linings Ceiling J oist C-H Profile
CSR 997

Above: 1 x 25m m
G YPR O C K Shaft Liner
B elow : 3 x 16m m
G YPR O C K FYR C H EK
C eiling Joist
Spacing (m m )
Allow able Span of Joist (m m )
C -H Profile D escription
64C H 55 102C H 55
600 1700 2450
300 2150 3100
N O TES TO TAB LE 9 & 10:
U niform D istributed Load = 0.25kPa. M axim um D eflection = Span360 or 10m m .
Single C -stud joist m em bers should be propped prior to fixing of top layers.
W here C -H profile joists are used, a C -H PR O FILE nogging is required at joints in G YPR O C K Shaft Liner.
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


23
Fix track to wall at
each joist with
2 x 0.6kN fasteners
Fix joist to track with
1 x N10 pan head
screw top and
bottom
Track
1.15mm BMT
C
eiling Joist
2 or 3 layers 16mm
GYPROCK FYRCHEK
2 layers 16mm
GYPROCK FYRCHEK
Refer to Perimeter
and Caulking details
FIG Z914: C-STUD J OIST END SUPPORT
SIDE FIX USING 1.15mm BMT TRACK
Fix track to wall at
each joist with
2 x 0.6kN fasteners
Fix joist to track with
1 x N10 pan head
screw top and bottom
Track
1.15mm BMT
C
-H
S
tud C
eiling Joist
2 or 3 layers 16mm
GYPROCK FYRCHEK
1 layer 25mm
GYPROCK SHAFT
LINER PANEL
Refer to Perimeter
and Caulking details
FIG Z917: C-H PROFILE J OIST END SUPPORT
SIDE FIX USING 1.15mm BMT TRACK
Fix each angle to
wall at each joist
with 1 x 1.0kN
fastener
Fix joist to angle
with 1 x N10 pan
head screw top and
bottom
Angle
1.5mm BMT
C
eiling Joist
2 or 3 layers 16mm
GYPROCK FYRCHEK
2 layers 16mm
GYPROCK FYRCHEK
Refer to Perimeter
and Caulking details
FIG Z915: C-STUD J OIST END SUPPORT
SIDE FIX USING 1.50mm BMT ANGLE
Wall
Stud
Track
Fix joist to track with
1 x N10 pan head
screw top and bottom
Loadbearing wall frame
(check for capacity)
Align joists
directly over
wall studs
2 or 3 layers 16mm
GYPROCK FYRCHEK
Refer to Perimeter
and Caulking details
C
eiling Joist
2 layers 16mm
GYPROCK FYRCHEK
Wall lining to suit fire rating
requirements
FIG Z916: C-STUD J OIST END SUPPORT
TOP FIX USING 0.55mm BMT TRACK
Suitable for all joist spans
Wall
Stud
Track
Fix joist to track with
1 x N10 pan head
screw top and bottom
Loadbearing wall frame
(check for capacity)
Align joists
directly over
wall studs
2 or 3 layers 16mm
GYPROCK FYRCHEK
C
-H
S
tud C
eiling Joist
1 x 25mm GYPROCK
SHAFT LINER PANEL
Wall lining to suit fire rating
requirements
Refer to Perimeter
and Caulking details
FIG Z918: C-H PROFILE J OIST END SUPPORT
TOP FIX USING 0.55mm BMT TRACK
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


24
Plasterboard
Fixing
G yprock plasterboard sheets should be installed w ith the
long edge at right angles to the direction of the fram ing to
w hich they are fixed.
Fire rated installations m ust be fastener fixed. Adhesive is
not perm itted.
Adhesive does not constitute a fixing system by itself and
m ust be used in conjunction w ith nails or screw s.
A dhesive daubs m ust be kept 200m m m inim um from
fastening points.
Fasteners are to be installed at 10 - 16m m from sheet
edges.
Sheets are to be held firm ly against fram e w hile fasteners
are positioned. W herever possible com m ence fastening
from the centre portion of the sheet, proceeding to the ends
and edges. Alternatively, start at one edge and w ork across
the sheet to the other edge.
Fasteners are to be driven hom e w ith the head slightly
below the surface of the sheet, but not punched through
the face linerboard. C are should be taken to avoid
dam aging the face or core of the plasterboard.
Plasterboard m ust not be fixed directly to steel thicknesses
greater than 1.2m m B M T.
Fixings to C C A treated tim bers m ust be class 3 screw s or
hot dip galvanised nails.
For prepainted m etal, LO S P or C C A treated tim ber
fram ing, use 1/3 spacing m ethod or full screw fixing.
Non Fire Rated Ceiling Systems
W hen directly fixing a single layer system , the plasterboard
sheets m ay be either all fastener fixed or fastener/adhesive
fixed.
W hen fixing a tw o layer system , the first layer m ust be all
fastener fixed. The second layer m ay be all fastener fixed
or adhesive/fastener fixed.
Fire Rated Ceiling Systems
Plasterboard m ust be fastener fixed only, adhesive is not
perm itted.
Fire rated ceiling system s m ust be installed strictly in
accordance w ith C SR G yprock specifications.
Plasterboard J oints
W herever possible, butt jointing of sheets on ceilings should
be avoided.
In non fire rated single layer system s, w here butt joints on
ceilings are positioned betw een fram ing m em bers, the sheet
ends m ust be reinforced (back-blocked), and depressed,
form ing a recess to enable jointing.
For detailed inform ation, refer to the G yprock Plasterboard
R esidential Installation G uide, N G YP547.
In m ulti-layer system s, butt joints in hidden layers are to be
form ed on fram ing m em bers and offset by 450m m m inim um
in consecutive layers. B utt joints in the final layer are to be
form ed w ithin 50m m of the centreline betw een m em bers,
offset by a m inim um of 450m m from previous layers and in
adjoining sheets, and fixed w ith lam inating screw s at 200m m
m axim um centres.
In m ulti-layer system s recessed joints in consecutive layers
m ust be offset by a m inim um of 300m m .
Control J oints
C ontrol joints are to be installed in fire rated continuous
interior ceiling areas, spaced at no m ore than 12m centres
in both directions, and as detailed in the Fram ing section
earlier in this guide.
Caulking
To attain the specified FRL, all perim eter gaps and penetrations
m ust be carefully and com pletely filled w ith G yprock

Fire
M astic. In som e cases, verm iculite plaster m ay be used. (Refer
to appropriate details). Verm iculite for caulking is to be m ixed
3:2 by volum e w ith cornice cem ent. U se sufficient w ater to
achieve a stiff w orkable m ix. Verm iculite plaster is not to be used
as a general purpose acoustic or fire rated caulking, except
w here detailed in this m anual. Verm iculite has no capacity to
accom m odate building m ovem ent.
In non fire rated system s, to attain the stated acoustic rating,
fill all gaps and around penetrations w ith G yprock W et Area
Acrylic Sealant or G yprock Fire M astic.
Curved Ceilings
For details on plasterboard fixing to curved ceilings, refer to
the G yprock Steel Fram e W all System s Installation G uide,
N G YP544.
Plasterboard J ointing & Finishing
R efer to the G yprock Plasterboard R esidential Installation
G uide, N G Y P 547 for detailed jointing and finishing
inform ation.
For non fire rated ceilings, inform ation is provided for various
Levels of Finish, including tolerances, back-blocking and
fastener spacing.
In m ulti-layer system s, jointing and finishing is required on
the visible outer layer only.
Laminating Screws
In 2 and 3 layer ceiling system s, G yprock

Lam inating
Screw s (40m m x N 10) m ay be used to lam inate layers of
plasterboard together at butt joints and control joints form ed
betw een fram ing.
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


25
TABLE 11: FIXING PLASTERBOARD TO SOFTWOOD
Plasterboard
Thickness
1st Layer 2nd Layer 3rd Layer
6.5m m
Plasterboard
2.8x40m m G al C lout or
2.8x25m m R ing Shank N ail or
Type S #6-18 x 25m m N P Screw
2.8x40m m G al C lout or
2.8x30m m R ing Shank N ail or
Type S #6-18 x 32m m N P Screw
10m m
Plasterboard
2.8x40m m G al C lout or
2.8x30m m R ing Shank N ail or
Type S #6-18 x 30m m N P Screw
2.8x50m m G al C lout or
Type S #6-18 x 40m m N P Screw
13m m
Plasterboard
2.8x40m m G al C lout or
2.8x30m m R ing Shank N ail or
Type S #6-18 x 32m m N P Screw
2.8x50m m G al C lout or
Type S #6-18 x 45m m N P Screw
3.75x75m m G al C lout or
Type S #8-15 x 65m m N P Screw or
#10x40m m Lam inating Screw (w alls only)
16m m
Plasterboard
2.8x50m m G al C lout or
Type S #6-18 x 32m m N P Screw
3.15x65m m G al C lout or
Type S #6-18 x 50m m N P Screw
3.75x75m m G al C lout or
Type S #8-15 x 65m m N P Screw or
#10x40m m Lam inating Screw (w alls only)
13m m + 16m m
Plasterboard
2.8x40m m G al C lout or
2.8x30m m R ing Shank N ail or
Type S #6-18 x 32m m N P Screw
2.8x50m m G al C lout or
Type S #6-18 x 45m m N P Screw
TABLE 12: FIXING PLASTERBOARD TO HARDWOOD
Plasterboard
Thickness
1st Layer 2nd Layer 3rd Layer
6.5m m
Plasterboard
2.8x30m m G al C lout or
2.8x25m m R ing Shank N ail or
Type S #6-18 x 25m m N P Screw
2.8x30m m G al C lout or
2.8x25m m R ing Shank N ail or
Type S #6-18 x 32m m N P Screw
10m m
Plasterboard
2.8x30m m G al C lout or
2.8x25m m R ing Shank N ail or
Type S #6-18 x 30m m N P Screw
2.8x40m m G al C lout or
Type S #6-18 x 32m m N P Screw
13m m
Plasterboard
2.8x30m m G al C lout or
2.8x25m m R ing Shank N ail or
Type S #6-18 x 32m m N P Screw
2.8x40m m G al C lout or
Type S #6-18 x 45m m N P Screw
3.15x65m m G al C lout or
Type S #8-15 x 65m m N P Screw or
#10x40m m Lam inating Screw (w alls only)
16m m
Plasterboard
2.8x40m m G al C lout or
Type S #6-18 x 32m m N P Screw
2.8x50m m G al C lout or
Type S #6-18 x 45m m N P Screw
3.15x65m m G al C lout or
Type S #8-15 x 65m m N P Screw or
#10x40m m Lam inating Screw (w alls only)
13m m + 16m m
Plasterboard
2.8x30m m G al C lout or
2.8x25m m R ing Shank N ail or
Type S #6-18 x 32m m N P Screw
2.8x50m m G al C lout or
Type S #6-18 x 45m m N P Screw
TABLE 13: FIXING PLASTERBOARD TO STEEL 0.5 0.8mm BMT
Plasterboard Thickness 1st Layer 2nd Layer 3rd Layer
6.5m m Plasterboard Type S #6-18 x 25m m N P Screw Type S #6-18 x 25m m N P Screw
10m m Plasterboard Type S #6-18 x 25m m N P Screw Type S #6-18 x 40m m N P Screw
13m m Plasterboard Type S #6-18 x 25m m N P Screw Type S #6-18 x 40m m N P Screw Type S #8-15 x 65m m N P Screw or
#10x40m m Lam inating Screw (w alls only)
16m m Plasterboard Type S #6-18 x 30m m N P Screw Type S #6-18 x 45m m N P Screw Type S #8-15 x 65m m N P Screw or
#10x40m m Lam inating Screw (w alls only)
13m m + 16m m
Plasterboard
Type S #6-18 x 25m m N P Screw Type S #6-18 x 45m m N P Screw
TABLE 14: FIXING PLASTERBOARD TO STEEL 0.8 2.0mm BMT
Plasterboard Thickness 1st Layer 2nd Layer 3rd Layer
6.5m m Plasterboard Type S #6-18 x 25m m D P Screw Type S #6-18 x 25m m D P Screw
10m m Plasterboard Type S #6-18 x 25m m D P Screw Type S #6-18 x 40m m D P Screw
13m m Plasterboard Type S #6-18 x 25m m D P Screw Type S #6-18 x 40m m D P Screw #10x40m m Lam inating Screw (w alls only)
16m m Plasterboard Type S #6-18 x 30m m D P Screw Type S #6-18 x 45m m D P Screw #10x40m m Lam inating Screw (w alls only)
13m m + 16m m
Plasterboard
Type S #6-18 x 25m m D P Screw Type S #6-18 x 45m m D P Screw
FIRE RATED NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


26
Perforated Plasterboard Installation
Notes On Fixing
P lan the layout of the sheets prior to application. It is
recom m ended that a border of standard G Y P R O C K
plasterboard at least 150m m w ide be provided around
the perim eter of the ceiling. S uitable fram ing m ust be
provided.
To align perforations, use a stringline or laser.
Fram ing m em bers m ust be positioned at 600m m centres
and coincide w ith non-perforated areas of sheets.
M ay be used in curved applications w ith 2.0m m inim um
radius.
A dditional details, including inform ation on preparing
suspended ceiling system s are provided in a later section
of this brochure.
Fixing Procedure Sheets
A pply G YP R O C K P erforated P lasterboard sheets w ith
paper bound edges at right angles to fram ing m em bers.
Align pattern to previously installed sheets and screw at
300m m m axim um centres.
If butt joints are required, centre joints on fram ing m em bers
and screw at 200m m centres opposed. B utt joints should
be staggered.
J oints
Tape and set joints using only approved G YPR O C K jointing
system s and use as detailed in the G yprock Plasterboard
R esidential Installation G uide, N G YP547.
D ue to the location of the perforations close to the edge of
panels, butt joints are of a narrow er w idth than is norm al.
Special care should be taken to ensure a good joint finish
w ithout filling of perforations.
FIG 20: INSTALLATION DETAIL
PERFORATED PLASTERBOARD SHEETS
Framing at 600mm centres
25mm GYPROCK screws
at 300mm centres
At butt joints, screw at
200mm centres opposed
Staggered butt joints
GYPROCK Perforated Plasterboard
(perforations not shown)
Border of standard GYPROCK plasterboard
or finish with wall angle trim
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


27
230mm
max.
centres
200mm
min. cts
200mm
min. cts
For 1350mm width sheets, hold
sheet with temporary fastener
through block at every second joist
until adhesive sets
Timber or steel
framing
2 Nails 50 to
75mm apart
or 1 screw
Offset butt joints in
adjoining sheets by
600mm minimum
Adhesive Daubs
For Level of Finish 4 and
5, where Butt Jointing is
unavoidable, joint centrally
between members and
back-block.
Where permitted, Butt Joint on
member (Levels of Finish 0 to 3)
Nail at 150mm
or screw at 200mm max.
300mm max.
for cornice finish
150mm max.
for set finish
FIG 21: INSTALLATION DETAIL SINGLE LAYER ADHESIVE & NAIL/SCREW FIXING
Notes On Fixing
Install sheets w ith paper bound edges at right angles to
joists/fram ing to w hich sheets are being fixed.
D aubs of adhesive m ust be 200m m m inim um from
fastening points.
Place edge fasteners at 10 to 16m m from sheet edge.
Fixing Procedure
R efer to Plasterboard Fixing for fastener details.
Apply stud adhesive to fram ing in accordance w ith the
follow ing table. U sing a broadknife, apply daubs 25m m
diam eter x 15m m high at 230m m m axim um centres and
at 200m m m inim um from fastening points at sheet edges
and centreline. O m it daubs at ends of sheets and at butt
joints.
Plasterboard
W idth (m m )
C onventional Spacing 1/3 Spacing
900 F A F/F A F F A F A F
1200 F A A F/F A A F F A F A F A F
1350 F A A F/F A A F F A F A F A F
F = Fastener A = Adhesive D aub
F/F = 1 Screw or 2 N ails at 50 75m m apart
Fixing & Spacing
Adhesive Daubs at
230mm max. centres
and 200mm min. from
fastener points
2 daubs
4 daubs
4 daubs
Nail/screw fix at each
frame member
2 nails at 50 to 75mm
apart or 1 screw at each
frame member
J oint within 50mm of
centre line between
framing and adhesive fix
back-block
Nail fix at 150mm or
screw fix at 200mm max.
centres
Nail fix at 150mm or
screw fix at 200mm max.
centres.
For cornice finish, fasten
at 300mm max. cts.
For set finish, fasten at
150mm max. cts.
Location
Field
Sheet
Width
900mm
1200mm
1350mm
Recessed
J oints
Centreline
of
Sheet
Butt J oints
between
framing
Butt J oints
on framing
Openings
Sheet Ends
Fixing Specifications
Fasteners Refer to Fastener Details
Adhesive Gyprock Stud Adhesive
Apply plasterboard and fasten one recessed edge at each
fram ing m em ber.
Press the sheet firm ly against the fram ing, then fasten along
the second recessed edge at each fram ing m em ber.
Fasten along the centreline of sheet at each fram ing
m em ber w ith 2 nails at 50 to 75m m apart or 1 screw .
W here butt joints are m ade on fram ing m em bers, nail fix
at 150m m or screw fix at 200m m m axim um centres.
W here butt joints are m ade betw een fram ing, join w ithin
50m m of centreline betw een fram ing and back-block joint.
B ack-block recessed joints w here required. R efer to the
G yprock

P lasterboard R esidential Installation G uide,


N G YP547 for full details.
O ffset b utt joints in ad joining sheets b y 600m m
m inim um .
Fasten around service openings w ith nails at 150m m or
screw s at 200m m m axim um centres.
Fasten ends of sheets at 300m m m axim um centres for
a cornice finish, or at 150m m m axim um centres for a set
finish.
U nder slow drying conditions, hold 1350m m w ide sheets
against the fram ing m em bers for at least 48 hours w ith
tem porary fasteners driven through plasterboard blocks
at every second fram e. R efer to installation detail.
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


28
Notes On Fixing
Install sheets w ith paper bound edges at right angles to the
furring /fram ing to w hich sheets are being fixed.
Place edge fasteners at 10 to 16m m from sheet edge.
Fixing Procedure
R efer to Plasterboard Fixing for fastener details.
First Layer
B egin w ith a half w idth sheet.
Apply plasterboard and fasten along recessed edges at
each fram ing m em ber.
Press the sheet firm ly against the fram ing and fasten the
body of the board to each fram ing m em ber at 300m m
m axim um centres.
U se th e fo llo w in g at each fram in g m em b er:
900m m w idth sheets 4 screw s equally spaced.
1200m m w idth sheets 5 screw s equally spaced.
1350m m w idth sheets 6 screw s equally spaced.
Fasten butt joints centred on fram ing m em bers at 200m m
m axim um centres.
Fasten around service openings at 200m m m axim um
centres.
Fasten ends of sheets at 300m m m axim um centres.
Second Layer
B egin w ith a full w idth sheet so that recess joints w ill be
offset from first layer by 300m m m in.
U sing a broadknife, apply adhesive daubs 25m m diam eter
x 15m m high at 230m m m axim um centres and 200m m
m inim um from fastening points at the edges and centreline
of the sheet. O m it daubs at ends of sheets and at butt
joints.
U se the follow ing daubs at each fram ing m em ber:
900m m w idth sheets 2 daubs.
1200m m w idth sheets 4 daubs.
1350m m w idth sheets 4 daubs.
Apply plasterboard and fasten one recessed edge at each
fram ing m em ber.
Press the sheet firm ly against the fram ing, then fasten along
the second recessed edge at each fram ing m em ber.
Fasten along the centreline of the sheet w ith 1 screw at
each fram ing m em ber.
O ffset butt joints in adjoining sheets and betw een layers
by 600m m m inim um and fasten at 200m m m axim um
centres.
Fasten around service openings at 200m m m axim um
centres.
Fasten ends of sheets at 300m m m axim um centres for
a cornice finish, or at 150m m m axim um centres for a set
finish.
U nder slow drying conditions, hold 1350m m w ide sheets
against the fram ing m em bers for at least 48 hours w ith
tem porary fasteners driven through plasterboard blocks
at every second fram e.
300mm
max.
200mm max.
Butt Joints in 1st
layer may be on
same member
Offset Butt Joints in 2nd
layer 600mm min. in
adjoining sheets and
between layers
Begin 1st layer
with a half
width sheet
Begin 2nd layer with a full width sheet
and offset recessed joint 300mm
minimum between 1st and 2nd layer
Timber or Steel Framing
at 600mm max. centres
For Level of Finish 4 and 5,
where Butt Jointing is
unavoidable, joint centrally
between members, fix with
laminating screws at 200mm
For Levels of Finish 0 to
3, Butt Joint on member
and screw fix at 200mm
max. centres
230mm
max.
300mm max.
for cornice finish
150mm max.
for set finish
200mm min.
230mm max.
200mm min.
Adhesive
Daubs
Temporary block
FIG 22: INSTALLATION DETAIL TWO LAYER SCREW & ADHESIVE FIXING
Fixing & Spacing
Screw fix to each framing
member at 300mm max.
centres
4 screws equally spaced
5 screws equally spaced
6 screws equally spaced
Screw fix at 200mm max.
centres
Screw fix at 300mm
max. cts.
Fixing & Spacing
Adhesive Daubs at
230mm max. centres
and 200mm min. from
fastener points
2 daubs
4 daubs
4 daubs
Screw fix at each
frame member.
Screw fix at each frame
member.
Screw fix at 200mm max.
centres.
Laminating screws at
200mm max. cts.
Screws at 200mm max.
centres.
For cornice finish, screw
fix at 300mm max. cts.
For set finish, screw fix at
150mm max. cts.
1st Layer
Body
Sheet Width
900mm
1200mm
1350mm
Butt J oints
on framing
Sheet Ends
& Openings
2nd Layer
Body
Sheet
Width
900mm
1200mm
1350mm
Recessed
J oints
Centreline
of Sheet
Butt J oints
on framing
Butt joints
between
framing
Openings
Sheet Ends
Fixing Specifications
1st Layer
Screws Refer to Fastener Details
2nd Layer
Adhesive Gyprock Stud Adhesive
Screws Gyprock 45S for steel
Gyprock 45W for timber
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


29
Notes On Fixing
Install sheets w ith paper bound edges at right angles to
the furring /fram ing to w hich sheets are being fixed.
Place edge fasteners at 10 to 16m m from sheet edge.
Fixing Procedure
R efer to Plasterboard Fixing for fastener details.
Apply plasterboard and fasten to each fram ing m em ber
along recessed edges.
Press the sheet firm ly against the fram ing and fasten the
body of the board to each fram ing m em ber w ith screw s
at 300m m m axim um centres.
U se th e fo llo w in g at each fram in g m em b er:
900m m w idth sheets 4 screw s equally spaced.
1200m m w idth sheets 5 screw s equally spaced.
1350m m w idth sheets 6 screw s equally spaced.
W here butt joints are m ade on fram ing m em bers, screw
fix at 200m m m axim um centres.
W here butt joints are m ade betw een fram ing, join w ithin
50m m of centreline betw een fram ing and back-block joint.
B ack-block recessed joints w here required. R efer to the
G yprock

P lasterboard R esidential Installation G uide,


N G YP547 for full details.
O ffset b utt joints in ad joining sheets b y 600m m
m inim um .
Fasten around service openings w ith screw s at 200m m
m axim um centres.
Screw fix ends of sheets at 300m m m axim um centres for
a cornice finish, or at 150m m m axim um centres for a set
finish.
Two Layer Systems
Fix the first layer as detailed for a single layer system ,
beginning w ith a half w idth sheet. B utt joints m ay be on
the sam e m em ber.
B egin the second layer w ith a full w idth sheet so that the
recess joints w ill be offset from the first layer joints by
300m m m inim um .
O ffset butt joints a m inim um of 600m m betw een layers
and betw een adjacent sheets in the second layer.
Fix the second layer using screw s applied to the sam e
specifications as detailed above for a single layer
system .
200mm max.
300mm max. for cornice finish
150mm max. for set finish
Offset butt joints in
adjoining sheets by
600mm minimum
For Level of Finish 4 and
5, where Butt Jointing is
unavoidable, support
plasterboard with additional
framing
Where permitted, Butt Joint
on member and screw fix at
200mm max. centres
(Levels of Finish 0 to 3)
200mm max.
Structural support
of timber, steel or
concrete
300mm
max.
Suspended Grid at
600mm maximum
centres
Practical
minimum 150mm
FIG 23: INSTALLATION DETAIL SINGLE LAYER SCREW FIXING
Fixing Specifications
Screws Refer to Fastener Details
Fixing & Spacing
Screw fix to each frame
at 10 to 16mm from
sheet edges and at
300mm max. centres
between.
4 screws equally spaced
5 screws equally spaced
6 screws equally spaced
J oint within 50mm of
centre line between
framing. Back-block and
fix with laminating screws
at 200mm max. centres.
Screw fix at 200mm max.
centres
Screw fix at 200mm max.
centres.
For cornice finish, screw
fix at 300mm max. cts.
For set finish, screw fix at
150mm max. cts.
Location
Recessed
J oints &
Body
Sheet
Width
900mm
1200mm
1350mm
Butt J oints
between
framing
Butt J oints
on framing
Openings
Sheet Ends
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


30
Notes On Fixing
Install sheets w ith paper bound edges at right angles to
the fram ing to w hich sheets are being fixed.
O ffset recess joints of 1st and 2nd layers by 300m m m in.
Place edge fasteners at 10 to 16m m from sheet edge.
Leave a 6m m gap around perim eter and caulk w ith
G yprock Fire M astic.
Single layer system s are to be installed as detailed for the
second layer. B utt joints are to be form ed w ithin 50m m of
the centreline betw een fram ing, fully back-blocked and fixed
w ith lam inating screw s at 200m m m axim um centres
Fixing Procedure
R efer to Plasterboard Fixing for fastener details.
First Layer
B egin w ith a half w idth sheet.
Apply plasterboard and fasten along recessed edges at
each fram ing m em ber.
Press the sheet firm ly against the fram ing and fasten the
body of the board to each fram ing m em ber at 200m m
m axim um centres.
U se th e fo llo w in g at each fram in g m em b er:
900m m w idth sheets 6 fasteners equally spaced.
1200m m w idth sheets 7 fasteners equally spaced.
1350m m w idth sheets 8 fasteners equally spaced.
Form butt joints centred on fram ing m em bers and fasten
at 150m m m axim um centres.
Fasten around openings at 150m m m axim um centres.
Fasten ends of sheets at a 200m m m axim um centres.
Second Layer.
B egin w ith a full w idth sheet so that recess joints w ill be
offset from first layer by 300m m m inim um .
Apply plasterboard and fasten recessed edges and body
of sheets as for the first layer.
Fasten around openings at 150m m m axim um centres.
O ffset butt joints in adjoining sheets by 600m m m inim um
and fix according to fram e spacing
Fram ing at 450m m m axim um spacing B utt joint on
fram ing and fasten at 150m m m axim um centres (or as
detailed for 600m m fram e spacing).
Fram ing at 600m m m axim um spacing B utt joint w ithin
50m m of the centreline betw een fram ing m em bers and
fix to the 1st layer w ith lam inating screw s at 200m m
m axim um centres.
Fasten ends of sheets at 200m m m axim um centres for
a cornice finish, or at 150m m m axim um centres for a set
finish.
200mm
max.
150/200mm max.
200mm max.
150mm
max.
Butt Joints in 1st
layer may be on
same member
Butt Joints in 2nd layer must be offset
600mm minimum in adjoining sheets and
between layers
Begin 1st
layer with half
width sheet
Begin 2nd layer with full width sheet
and offset recessed joint 300mm
minimum between 1st and 2nd layer
For framing at 600mm
max. centres, Butt
Joints in 2nd layer must
be centred between framing
members
For framing at 450mm centres,
Butt Joints in 2nd layer may be
on or centrally between framing
members
Suspended Grid,
Timber or Steel Framing
at 600mm max. centres
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)
FIG 24: INSTALLATION DETAIL ONE OR TWO LAYER NAIL OR SCREW FIXING
Fixing Specifications
Fasteners Gyprock Nails or Screws
Refer to Fastener Details
Fixing & Spacing
Fasten to each framing
member at 10 to 16mm
from sheet edges and
at 200mm maximum
centres
6 fasteners equally spaced
7 fasteners equally spaced
8 fasteners equally spaced
Butt J oint on framing and
fasten at 150mm max.
centres.
Framing at 450mm max.
spacing Butt J oint on
framing and fasten at
150mm max. centres (or
as detailed for 600mm
frame spacing).
Framing at 600mm max.
spacing Butt J oint
within 50mm of centre
line between framing
and fix to 1st layer with
Laminating Screws at
200mm maximum cts.
Fasten at
150mm max. centres
Cornice finish Fasten at
200mm max. centres
Set finish Fasten at
150mm max. centres
Location
Body of
Sheet
1st & 2nd
Layer
Sheet
Width
900mm
1200mm
1350mm
Butt
J oints
1st layer
Butt
J oints
2nd layer
Openings
Sheet
Ends
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


31
Notes On Fixing
Install sheets w ith paper bound edges at right angles to
the fram ing to w hich sheets are being fixed.
O ffset recess joints betw een layers by 300m m m in.
Place edge fasteners at 10 to 16m m from sheet edge.
Leave a 6m m gap around perim eter and caulk w ith
G yprock Fire M astic.
Fixing Procedure
R efer to Plasterboard Fixing for fastener details.
First Layer
B egin w ith a 400m m w idth sheet so that recess joints w ill
be offset from second layer.
Apply plasterboard and screw fix along recessed edges
at each fram ing m em ber.
Press the sheet firm ly against the fram ing and fasten the
body of the board to each fram ing m em ber w ith screw s
at 200m m m axim um centres.
U se th e fo llo w in g at each fram in g m em b er:
900m m w idth sheets 6 fasteners equally spaced.
1200m m w idth sheets 7 fasteners equally spaced.
1350m m w idth sheets 8 fasteners equally spaced.
Form butt joints centred on fram ing m em bers and fasten
at 150m m m axim um centres.
Fasten around openings w ith at 150m m m axim um
centres.
Fasten ends of sheets at a 200m m m ax. centres.
Second Layer
B egin w ith an 800m m w idth sheet. O ffset recess joints
300m m m inim um from the previous layer. O ffset butt joints
betw een layers by 600m m m inim um .
Fasten 2nd layer sheets as for first layer.
Third Layer
B egin w ith a full w idth sheet. O ffset recess joints 300m m
m inim um from the previous layer. O ffset butt joints in
adjoining sheets and from previous the layers by 600m m
m inim um .
Apply plasterboard and fasten recessed edges, body of
sheets and around openings as for previous layers.
B utt joint w ithin 50m m of the centreline betw een fram ing
and fix to previous layers w ith G yprock

Lam inating
Screw s (40m m x N 10) at 200m m m axim um centres.
Fasten ends of sheets at a 200m m m axim um centres for
a cornice finish, or at a 150m m m axim um centres for a
set finish.
200mm max.
150/200mm max.
200mm
max.
150mm
max.
150mm
max.
Butt Joints in 3rd layer
must be placed centrally
between framing, offset
600mm minimum in adjoining
sheets and from previous layers
Begin 1st layer with 400mm width sheet
Begin 2nd layer with 800mm width sheet
Begin 3rd layer with full width sheet
1st and 2nd layer
Butt Joints on
framing members,
offset 600mm minimum
between layers
Suspended Grid, Steel
Framing or Timber Framing at
600mm maximum centres
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)
FIG 25: INSTALLATION DETAIL THREE LAYER FIXING TO STEEL OR TIMBER FRAMING NAIL OR SCREW FIXING
Fixing & Spacing
Fasten to each framing
member at
10 to 16mm from sheet
edges and at 200mm
maximum centres
6 fasteners equally spaced
7 fasteners equally spaced
8 fasteners equally spaced
Butt J oint on framing and
fasten at 150mm max.
centres.
Butt J oint within
50mm of centre line
between framing and
fix to previous layer with
Laminating Screws at
200mm max. centres
Cornice finish, fasten at
200mm max. centres
Set finish, fasten at
150mm max. centres
Fasten at
150mm max. centres
Location
Body of
Sheet
All Layers
Sheet
Width
900mm
1200mm
1350mm
Butt
J oints
1st & 2nd
Layers
Butt
J oints
3rd layer
Sheet
Ends
Openings
Fixing Specifications
Fasteners Refer to Fastener Details
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


32
Perimeter Framing & Caulking
600mm max.
GYPROCK
Plasterboard
1 or 2 layers of
GYPROCK FYRCHEK 1 or 2 layers of
GYPROCK FYRCHEK
Angle may be
required as backing
for caulking
Non fire
rated or
lower
rated
timber
wall
system GYPROCK
Plasterboard
Ceiling Joist
Packer to suit
Blocking to suit FRL. Refer to 'National
Association of Forest Industries Ltd'
publication 'MRTFC'
NOTE: Caulking of the
ceiling perimeter may
be necessary before
fixing wall linings
Refer to FIG Z100
Rondo Wall Track fixed at
600mm max. centres
200mm max. 600mm max.
Ceiling Joist
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
50x50mm Plasterers Steel
Angle or Wall Track fixed at
600mm max. centres
Rondo Wall Track fixed at
600mm max. centres
GYPROCK
Plasterboard
GYPROCK
Plasterboard
Non fire
rated or
lower
rated
timber
wall
system
Blocking to suit FRL. Refer to 'National
Association of Forest Industries Ltd'
publication 'MRTFC'
NOTE: Caulking of the
ceiling perimeter may
be necessary before
fixing wall linings
Refer to FIG Z100
FIG Z103 FIG Z104
CEILING PERIMETER FRAMING AT J UNCTION WITH TIMBER FRAMED WALL
FIG Z101 FIG Z102
FIG Z100: CEILING PERIMETER FRAMING AND CAULKING SELECTION
At ceiling/w all junctions, ceiling fram ing is required to support the plasterboard as detailed in FIG Z101 to FIG Z130 To seal the
junction betw een the ceiling and w all, one of the caulking details FIG Z140 to FIG Z147 m ust be used. The junction detail should
be selected w ith regard to appearance and acoustic integrity.
Step 1:
C hoose a suitable
ceiling perim eter
fram ing detail.
R efer to
FIG Z101 to
FIG Z130.
Step 2:
C hoose a suitable
perim eter caulking
detail.
R efer to
FIG Z140 to
FIG Z147.
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


33
200mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Fire rated
wall system
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
Refer to FIG Z100
600mm max.
FIG Z111 FIG Z112
600mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Fire rated
wall system
Steel Angle or Track fixed
at 600mm max. centres
with metal fasteners
Steel Track fixed at
600mm max. centres
with metal fasteners
Refer to FIG Z100
FIG Z113 FIG Z114
200mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Steel Angle fixed at
600mm max. centres with
metal fasteners
Steel Angle fixed at
600mm max. centres with
metal fasteners
600mm max.
Refer to FIG Z100
Fire rated
wall system
FIG Z115 FIG Z116
CEILING PERIMETER FRAMING AT J UNCTION WITH FIRE RATED STEEL FRAMED WALL
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


34
Wall track or angle fixed at
600mm max. centres with
metal fasteners
600mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Refer to FIG Z100
Masonry
wall system
CEILING PERIMETER FRAMING AT J UNCTION WITH MASONRY WALL
1, 2 or 3 layers of
GYPROCK FYRCHEK
600mm max.
Continuous strip of 16mm
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Masonry
wall system
Ceiling Joist
Rondo Wall Track
Packer to suit
Angle may be required
as backing for caulking
Refer to FIG Z100
FIG Z123 FIG Z124
FIG Z121 FIG Z122
Render
1, 2 or 3 layers of
GYPROCK FYRCHEK
Rondo Wall Track
Packer to suit
600mm max.
Render
1, 2 or 3 layers of
GYPROCK FYRCHEK
Wire Mesh (galvanised)
nailed to wall plate
Ceiling Joist
Masonry
wall system
Angle may be
required as backing
for caulking
Refer to FIG Z100
FIG Z125 FIG Z126
GYPROCK
Plasterboard CD
GYPROCK
Plasterboard CD
1, 2 or 3 layers of
GYPROCK FYRCHEK
600mm max.
Gyprock Masonry Adhesive
(large daubs to bridge cavity)
1, 2 or 3 layers of
GYPROCK FYRCHEK
Masonry
wall system Rondo Wall Track
Packer to suit
Ceiling Joist
Angle may be
required as backing
for caulking
Refer to FIG Z100
FIG Z127 FIG Z128
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


35
10mm
min.
W
a
l
l

S
y
s
t
e
m
Continuously fill gap at
edge of sheet with
CSR Gyprock

Fire Mastic
min. 16mm depth
Backing rod
(non fire rated)
Framing to appropriate detail
FIG Z140
Suitable for 2 and 3 layer plasterboard ceiling systems.
Caulking Details for Fire Rated Ceilings
Perim eter caulking details Z140 to Z147 w ill m aintain the FR L of the C SR G yprock ceiling system s in w hich they are installed.
These details (excluding Z146 and Z147) are also suitable w here acoustic integrity is required.
Shadowline stopping bead
Rondo P50
W
a
l
l

S
y
s
t
e
m
Framing to appropriate detail
Continuously fill gap at
edge of sheet with
CSR Gyprock

Fire Mastic
min. 16mm depth
FIG Z141
Suitable for 2 and 3 layer plasterboard ceiling systems.
Trowel on a continuous
25 x 25mm fillet
of Vermiculite plaster
W
a
l
l

S
y
s
t
e
m
Framing to appropriate detail
6mm max. gap
FIG Z142
Suitable for 1, 2 and 3 layer plasterboard ceiling systems.
Continuously fill gap at
edge of all sheets with
CSR Gyprock

Fire Mastic
6mm gap min.
W
a
l
l

S
y
s
t
e
m
Framing to appropriate detail
FIG Z143
Suitable for 2 and 3 layer plasterboard ceiling systems.
W
a
l
l

S
y
s
t
e
m
Continuously fill gap at
edge of all sheets with
vermiculite plaster
6mm gap min.
Tape and set joint
Framing to appropriate detail
FIG Z144
Suitable for 1, 2 and 3 layer plasterboard ceiling systems.
W
a
l
l

S
y
s
t
e
m
Continuously fill gap at
edge of all sheets with
Vermiculite plaster
6mm gap min.
Timber moulding
Framing to appropriate detail
FIG Z145
Suitable for 1, 2 and 3 layer plasterboard ceiling systems.
200mm max.
1, 2 or 3 layers of
GYPROCK FYRCHEK
1, 2 or 3 layers of
GYPROCK FYRCHEK
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
Masonry
wall system
Refer to FIG Z100
600mm max.
FIG Z129 FIG Z130
CEILING PERIMETER FRAMING AT J UNCTION WITH MASONRY WALL
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


36
Ceiling Perimeter J unctions to control
Room to Room Noise via Ceiling Space
To achieve stated acoustic isolation (C AC ) values for G yprock C eiling System s, it is necessary to install one of the follow ing w all
to ceiling junction details. The acoustic perform ance of set plasterboard ceilings can be m aintained if there are no penetrations
in the ceiling or the penetrations are acoustically treated. U ntreated penetrations can result in up to a 10dB loss in integrity.
FIG Z800: WALL/CEILING J UNCTION
13mm GYPROCK
plasterboard CD
continuous over wall
Tape and
set corner
Ceiling Framing
Apply sealant
above track and fix
wall track to ceiling
framing
FIG Z803: WALL/CEILING J UNCTION
Two continuous
beads of Gyprock
Wet Area Acrylic
Sealant above wall
track
Finish Bead as
required
Screw fix ceiling
tile to wall track
GYPROCK 10mm
Ceiling Panel
Rondo DUO Two-way
Steel Grid Ceiling Frame
FIG Z801: WALL/CEILING J UNCTION
13mm GYPROCK
plasterboard CD
continuous over wall
Tape and
set corner
Ceiling Framing
1200mm min. 1200mm min.
Bradford 75mm
Anticon

Insulation
Apply sealant
above track and fix
wall track to ceiling
framing
FIG Z802: WALL/CEILING J UNCTION
13mm GYPROCK
plasterboard CD
Tape and
set corner
Ceiling Framing
1200mm min. 1200mm min.
Bradford 75mm
Anticon

Insulation
100mm
min
6mm gap
max.
70mm max.
Wall Angle Trim
Rondo DUO 5 fixed to
wall with metal
fasteners at 600mm
max. centres
NOTE: Wall surface
behind angle must be
flush. Fill any raked
joints behind angle.
Masonry
wall system
FIG Z146:
Suitable for 1, 2 and 3 layer plasterboard ceiling systems.
NOTE: This detail is not suitable were acoustic integrity is
required.
22mm IBS rod
Shadowline stopping bead
Rondo P50
W
a
l
l

S
y
s
t
e
m
Framing to appropriate detail
FIG Z147;
Suitable for 2 and 3 layer plasterboard ceiling systems.
NOTE: This detail is not suitable were acoustic integrity is
required.
FIRE RATED
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


37
Fire Rated Ceiling Control Joints
Continuously fill gap
with CSR Gyprock


Fire Mastic to depth
of first layer minimum
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
Furring
Channel
60 to 70mm
RONDO P35
Control Joint
with set finish
2 layers GYPROCK
FYRCHEK
plasterboard screw
fixed to furring each
side of joint at 200mm
max. centres
15 to 20mm gap
FIG Z034: CONTROL J OINT
PARALLEL TO STEEL FRAMING 2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock


Fire Mastic to depth
of first layer minimum
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Furring
Channel
each side
of joint
60 to 70mm
RONDO P35
Control Joint
with set finish
1st and 2nd layers of
GYPROCK FYRCHEK
plasterboard fixed to
furring at 200mm max.
centres
3rd layer of GYPROCK
FYRCHEK plasterboard
fixed with laminating screws
at 200mm max. centres
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
FIG Z037: CONTROL J OINT
PARALLEL TO STEEL FRAMING 3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock


Fire Mastic to depth
of first layer minimum
Furring Channel
Joiner N138
Back-block between furring
channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet
200mm min.
RONDO P35
Control Joint
with set finish
Furring Channel
GYPROCK FYRCHEK
plasterboard fixed with
laminating screws to
layer above at 200mm
max. centres
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
FIG Z035: CONTROL J OINT
PERPENDICULAR TO STEEL FRAMING 2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock


Fire Mastic to depth
of first layer minimum
Back-block between furring
channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet
200mm min.
RONDO P35
Control Joint
with set finish
2nd and 3rd layers of
GYPROCK FYRCHEK
plasterboard fixed with
laminating screws to
layer above at 200mm
max. centres
Furring Channel
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
FIG Z038: CONTROL J OINT
PERPENDICULAR TO STEEL FRAMING 3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
Furring
Channel
60 to 70mm
RONDO P35
Control Joint
with set finish
1 layer GYPROCK
FYRCHEK
plasterboard screw
fixed to furring
channel each side of
joint at 200mm max.
centres
FIG Z073: CONTROL J OINT
PARALLEL TO STEEL FRAMING 1 LAYER
(Maintains FRL of the ceiling system in which it is installed).
Back-block between furring
channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet
200mm min.
RONDO P35
Control Joint
with set finish
Furring Channel
GYPROCK FYRCHEK
plasterboard fixed to
N140 Track at 200mm
max. centres
Rondo N140 Track
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
15 to 20mm gap
FIG Z074: CONTROL J OINT
PERPENDICULAR TO STEEL FRAMING 1 LAYER
(Maintains FRL of the ceiling system in which it is installed).
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


38
Continuously fill gap
with CSR Gyprock


Fire Mastic to depth
of first layer minimum
Back-block between trimmers
with GYPROCK FYRCHEK same
thickness as ceiling sheet
Laminating screws at
200mm max. centres
RONDO P35
Control Joint
with set finish
200mm min.
Laminating screws at
200mm max. centres
GYPROCK
FYRCHEK
plasterboard
Joist Joist
Trimmers at 450mm
max. centres
15 to 20mm gap
FIG Z040: CONTROL J OINT
PARALLEL TO TIMBER FRAMING 2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock


Fire Mastic to depth
of first layer minimum
Back-block between trimmers
with GYPROCK FYRCHEK same
thickness as ceiling sheet
Laminating screws at
200mm max. centres
200mm min.
Laminating screws at
200mm max. centres
GYPROCK
FYRCHEK
plasterboard
Joist
300mm min.
RONDO P35
Control Joint
with set finish
Aluminium Foil under joist,
300 x 150 x 0.15mm
15 to 20mm gap
FIG Z041: CONTROL J OINT PERPENDICULAR TO
TIMBER FRAMING 2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap with CSR
Gyprock

Fire Mastic to depth


of one layer minimum
Back-block between trimmers
with GYPROCK FYRCHEK same
thickness as ceiling sheet
RONDO P35
Control Joint
with set finish
Fix 2nd and 3rd layers to
preceeding layer with
laminating screws at
200mm max. centres
GYPROCK
FYRCHEK
plasterboard
Aluminium Foil under joist,
300 x 150 x 0.15mm
Fix back-block to ceiling sheet
with plaster based adhesive
or laminating screws
15 to 20mm gap
200mm min.
300mm min.
Joist
FIG Z044: CONTROL J OINT PERPENDICULAR TO
TIMBER FRAMING 3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously fill gap
with CSR Gyprock


Fire Mastic to depth
of first layer minimum
Back-block between trimmers
with GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix back-block to ceiling sheet
with plaster based adhesive
or laminating screws
RONDO P35
Control Joint
with set finish
200mm min.
Fix 2nd and 3rd layers to
preceeding layer with
laminating screws at 200mm
max. centres
GYPROCK
FYRCHEK
plasterboard
Joist Joist
Trimmers at 450mm
max. centres
15 to 20mm gap
FIG Z043: CONTROL J OINT
PARALLEL TO TIMBER FRAMING 3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
Continuously and
completely fill gap
with CSR Gyprock


Fire Mastic
Laminating screws at
200mm max. centres
10 to 12mm gap
RONDO
Stopping Bead
with set finish
1 layer GYPROCK
FYRCHEK plasterboard
continuous across joint
FIG Z042: CONTROL J OINT PARALLEL OR
PERPENDICULAR TO TIMBER OR STEEL FRAMING
2 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
NOTE: Aluminium Foil
must be placed under
joist where control joint is
perpendicular to framing.
Refer to FIG Z041.
NOTE: Control J oint must be placed
centrally between joists when
installed parallel to framing
Continuously and
completely fill gap
with CSR Gyprock


Fire Mastic
Laminating screws at
200mm max. centres
10 to 12mm gap
RONDO
Stopping Bead
with set finish
2 layers GYPROCK
FYRCHEK plasterboard
continuous across joint
FIG Z045: CONTROL J OINT PARALLEL OR
PERPENDICULAR TO TIMBER OR STEEL FRAMING
3 LAYERS
(Maintains FRL of the ceiling system in which it is installed).
NOTE: Aluminium Foil must
be placed under joist where
control joint is perpendicular to
framing. Refer to FIG Z044.
NOTE: Control J oint must be placed
centrally between joists when
installed parallel to framing
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


39
Access & Air Conditioning
Penetrations in Ceilings
FIRE RATED
Ceiling cut-out equal
to hatch frame size
Fire rated access panel installed
to manufacturers specifications
Ceiling Joists/Trimmers around
all sides of opening
GYPROCK FYRCHEK
plasterboard ceiling lining
FIG Z032: FIRE HATCH IN CEILING
30mm Bradford
Fireseal Damper Strip
Air Diffuser
Volume Dampers
Ceiling
suspension
system
A
Fire Damper
Fire Damper
Frame
Furring Channel
Part N129
GYPROCK FYRCHEK
plasterboard layers
and thickness
appropriate for system
Top Cross Rail
Part N128
AC Duct and Damper
supported independently
to ceiling system
FIG Z033: AIR CONDITIONING DUCT/DAMPER
PENETRATION IN CEILING
FRL 60/60/60 TEST: SI 1585
Air Diffuser
Volume Dampers
Fire
Damper
AC Duct and Damper
supported independently
to ceiling system
Furring Channel
Part N129
GYPROCK FYRCHEK
plasterboard layers
and thickness
appropriate for system
Top Cross
Rail Part
N128
Ceiling
suspension
system
Fusible Link
30mm Bradford
Fireseal Damper Strip
VIEW FROM A
The system detailed in FIG Z033 incorporates a 600 x 400
x 0.76m m galvanised steel duct incorporating a single
blade fire dam per w ith an opening size of 460m m x 460m m
(B lendair C FD I 450 x 450m m single blade fire and sm oke
dam per or equivalent).
The design incorporates a 450 x 450m m alum inium volum e
dam per located in the fir dam per, and a 600 x 600m m face
size by 0.76m m steel diffuser for the air outlet.
Penetrations for Access Panels and Air Conditioning
Gyprock

Ceiling Systems Installation Guide


40
FIG Z054: GYPROCK FIRE SPRING
FITTED DURING CEILING INSTALLATION
TESTED TO AS1530.4
CSR Gyprock
Fire Mastic
CSR Gyprock
Fire Spring
Two layers
16mm
GYPROCK
FYRCHEK
CSR Gyprock
Fire Mastic
CSR Gyprock
Fire Spring
Two layers
16mm
GYPROCK
FYRCHEK
FIG Z055: GYPROCK FIRE SPRING
FITTED AFTER CEILING INSTALLATION
TESTED TO AS1530.4
Ceilings Fire Rated
The G yprock Fire Spring is a steel coil approxim ately 25m m
in diam eter and 170m m in length. It is designed to keep
pow er cables aw ay from com bustible m aterials, effectively
elim inating the need to back-blockthe w iring.
The G yprock

Fire Spring is used in plasterboard ceiling


system s required to be resistant to the incipient spread of
fire.
The G yprock

Fire Spring can be installed during ceiling


construction as show n in FIG Z054, or once the ceiling has
been installed as show n in FIG Z055.
Electrical Penetrations
FIG Z056: BACK-BLOCKING OF ELECTRICAL
PENETRATION ON CEILING
Two 100 x 100mm
blocks of 16mm
GYPROCK
FYRCHEK
Recess 1st block
to accommodate
wiring
Alternately, w here electrical w ires or conduits penetrate a fire
rated ceiling, the penetration m ust be back-blocked w ith tw o
100 x 100m m pieces of 16 m m G YPR O C K FYR C H EK.
R ecess the low er piece to accom m odate the w iring, and fix
both blocks in position w ith G yprock

C ornice C em ent or
G yprock B ase C oat 45 or 60.
Timber flooring
Floor Joist
Trimmers
50 x 50mm min.
1 or 2 layers of GYPROCK
FYRCHEK plasterboard
Floor Joist
Trimmer
50 x 50mm min.
Nogging
50 x 50mm min.
FIG Z057: RECESSED LIGHT CAVITY
IN TIMBER FRAME
(M aintains the FR L of the w all system in w hich it is installed).
Framing Detail
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


41
FIG Z059: SURFACE MOUNTED LIGHT
PERPENDICULAR TO FURRING CHANNELS
Additional short
length of Top Cross
Rail to support
Furring Channels
Light Fitting screw fixed
to Furring Channels
FIG Z060: SURFACE MOUNTED LIGHT
PARALLEL TO FURRING CHANNELS
Additional short
length of Top Cross
Rail to support
Furring Channels
Light Fitting screw fixed
to Furring Channel
FIG 26: FIRE RATED REGAL HALOGEN DOWNLIGHT
R egal type R 1012/FR D dow nlight is suitable for FR L 60/60/60 and 60
m inute R ISF.
312mm
312mm
670mm
Fabricated box 0.5mm
galvanised steel 1230L x
285W x 120H mm
Wiring
penetration
2 layers 16mm GYPROCK
FYRCHEK screw fixed to
steel box at 300mm max.
centres
Hanging bolts
1
2
9
4
m
m
to
o
u
ts
id
e

o
f s
h
e
e
tin
g
450mm
50 50
Protection box
Cup head bolts
85 x 7mm
Light fitting
support
285mm
1
4
1
m
m
Light trim
250 x 50 x 3mm
support 2 layer x 16mm
GYPROCK FYRCHEK
1
2
7
m
m
7mm
Stirrup fabricated
from stud or furring
and N226 clips
FIG Z058: RECESSED LIGHT BOX IN SUSPENDED
STEEL FRAME CEILING
(M aintains the FR L of the w all system in w hich it is installed)
(C om ponents not supplied by C SR )
Top
Cross
Rail
Support stirrup
fabricated from stud
or furring channel
and N226 clips
Recessed light
protection box Furring
Channel
Suspension
Rod
Suspension
Clip
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


42
100mm max.
Gyprock Fire
Mastic
6mm
15mm min.
IBS Strip
60 x 20mm
Wire Mesh
Shield
diameter
twice that
of pipe
1, 2 or 3 layers
of GYPROCK
FYRCHEK
plasterboard
FIG Z069:
COPPER PIPE PENETRATION THROUGH CEILING
(M aintains the FR L of the ceiling system in w hich it is installed).
1, 2 or 3 layers
of GYPROCK
FYRCHEK
plasterboard
PROMAT
Fyre Collar
fixed to support
framing
Additional support
framing if required
PVC Pipe
FIG Z070:
PVC PIPE PENETRATION THROUGH CEILING
(M aintains the FR L of the ceiling system in w hich it is installed).
Installation m ust be to fire rated collar m anufacturers specifications.
Sprinkler Pipes
The penetration through fire rated ceilings for sprinkler pipes
should not exceed the pipe diam eter plus 10m m .
The hole m ust be cut using a hole saw .
O nce the pipe is in position caulk around the sprinkler head
w ith G yprock Fire M astic.
Sprinkler pipe
Support sprinkler
pipe independently
of ceiling lining
Hole diameter =
Pipe diameter +
10mm max.
Caulk gap with
Gyprock Fire
Mastic
1, 2 or 3 layers of
GYPROCK
FYRCHEK
Plasterboard
FIG Z071: FIRE SPRINKLER PIPE PENETRATION
THROUGH CEILING
(M aintains the FR L of the ceiling system in w hich it is installed).
Plumbing Penetrations
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


43
Track screw fixed to
longitudinal framing at
ends of beam
Cut flanges of (N140)
track to fit between
longitudinal framing
GYPROCK
FYRCHEK
plasterboard screw
fixed to nogging at
300mm maximum
centres
FIG 28: NOGGING TRACK INSTALLATION DETAIL
G yprock

U niversal Encasem ent C lips are friction fitted to


the rem aining colum n/beam flanges at 800m m m axim um
centres and 150m m m axim um from each end of the steel
colum n/beam .
W all Furring Track (R ondo N 140) is held in the back tongue
of the clip to form a steel fram ew ork for plasterboard
attachm ent.
N ogging track m ust be installed at each end of the colum n/
beam (and behind plasterboard butt joints in single layer
system s) to enable plasterboard fixing..
Introduction
C S R G yprock

has developed a series of plasterboard


encasem ent system s w hich provide up to 180 m inutes fire
resistance for structural beam s.
G yprock

system s are available for encasem ent of beam s


m ade from steel or tim ber.
Caulking
To attain the specified FR L, all perim eter gaps and
penetrations m ust be carefully and com pletely filled w ith
G yprock Fire M astic.
Steel Beams
Universal Encasement Clip
The G yprock U niversal Encasem ent C lip is m anufactured
from 1m m galvanised steel, and has been designed to suit
com m on steel flange thicknesses betw een 6 and 28m m .
The clip slides onto the steel beam flange and holds in place
via integral punched grips. R ondo N 140 w all Furring Track is
held in the back tongue to form fram ew ork for plasterboard
fixing.
Plasterboard Fixing
W here the w idth of plasterboard sheet is greater than
600m m , additional nogging support m ust be installed at
600m m m axim um centres along the beam /colum n.
C ut flanges of (N 140) track appropriately to form nogging
and screw fix each end to the adjacent longitudinal tracks.
G YPR O C K FYR C H EK plasterboard m ust be screw fixed to
all furring and nogging track at 200m m m axim um horizontal
and vertical centres.
Fix subsequent layer(s) of plasterboard to the sam e
specifications. Ensure plasterboard layers provide a zig-zag
corner joint at all corners.
Provide a 6m m gap betw een sheet ends and abutting w alls/
ceilings/floors and caulk w ith G yprock Fire M astic.
B utt joints in consecutive layers of plasterboard m ust be
staggered a m inim um of 300m m . Fix each layer to the
adjacent layer along all butt joint edges using G yprock


Lam inating Screw s at 200m m m axim um centres.
Steel Beam
Rondo Wall
Furring Track
N140 held in
back tongue of
Universal Clip
FIG 27: GYPROCK

UNIVERSAL ENCASEMENT CLIP


Framing
M etal angle m ust be fixed to the soffit or ceiling fram ing
at 600m m m axim um centres and at 100m m m axim um
from each end, and aligned to provide a fram ew ork for
plasterboard fixing.
FIRE RATED
Beam Encasement
Gyprock

Ceiling Systems Installation Guide


44
Screw fix each layer to
all framework at
200mm maximum
centres
Offset Butt Joints
300mm min. between
layers and fasten all
butt joints at 200mm
max. centres with
laminating screws
Gyprock Universal
Encasement Clips at
800mm maximum centres
along beam flanges and
150mm maximum from
each end of beam
Rondo Wall Furring
Track (N140) held in
back tongue of Gyprock
Universal Encasement
Clips
Tape and set
external angles
200mm
max.
200mm
max.
Metal Angle fixed to
soffit at 600mm
maximum centres and
100mm maximum from
each end
Caulk all
gaps
between
plasterboard
and metal
angle eith
Gyprock Fire
Mastic
FIG 29: STEEL BEAM ENCASEMENT SYSTEM FIRE RATED THREE SIDED PLASTERBOARD FIXING
Gyprock Universal
Encasement Clips
Caulk all gaps with
Gyprock Fire Mastic
Metal Angle fixed to soffit at
600mm maximum centres and
100mm maximum from each end
Rondo Wall Furring
Track (N140)
clipped along
flanges of beam
Each layer of
GYPROCK
FYRCHEK
plasterboard fixed at
200mm maximum
centres to all
framing
200mm
max.
200mm max.
200mm
max.
200mm
max.
200mm
max.
GYPROCK
FYRCHEK
plasterboard
Caulk 6mm gap at wall
junction with Gyprock Fire
Mastic
FIG 30: TIMBER BEAM ENCASEMENT SYSTEM
FIRE RATED SINGLE AND FIRST LAYER FIXING
Ceiling sheet butted
against beam
Soffit sheet flush with
edge of side sheet
GYPROCK
FYRCHEK
plasterboard
200mm
max.
200mm
max.
200mm
max.
Butt Joints offset
minimum 300mm
between layers
Caulk 6mm gap at wall
junction with Gyprock Fire
Mastic
FIG 31: TIMBER BEAM ENCASEMENT SYSTEM
FIRE RATED SECOND/THIRD LAYER FIXING
(Third layer m ust be fixed to the sam e specifications).
Fix ceiling layer
before applying
layer to beam
Tape and set
external angle
The G yprock Tim ber B eam Encasem ent System s provide
up to 120 m inutes structural fire resistance to tim ber beam
sections.
All nails m ust have a m inim um penetration into the tim ber
of 20m m .
Timber Beams
FIRE RATED
Gyprock

Ceiling Systems Installation Guide


45
Introduction
G yprock Panel C eiling System s are an attractive, econom ical
and functional solution for com m ercial and industrial ceilings
in offices, shops and shopping centres, hospitals and nursing
hom es, school and university buildings, clubs, restaurants,
function centres and com m unity buildings, w arehouse and
factory buildings.
There is a range of G yprock Panel C eiling System s to suit
both decorative and acoustic requirem ents. Advantages
include:
Fast, easy and inexpensive to install. Panels sim ply sit in
a tw o-w ay grid suspended fram e.
Panels in grid system s provide ready access to services
located above.
D im ensionally stable panels that w ill not buckle, shrink or
w arp. U nder norm al usage, deflection is m inim al w ell
w ithin the stringent tolerances set by AS2785.
Virtually m aintenance free.
Vinyl lam inate finished panels sim ply w ipe clean w ith a
dam p cloth.
System s easily adapt to accept flush m ounted lighting
system s.
Panels can be easily cut on-site using a trim m ing knife
or panel saw to fit around colum ns, sprinklers and to
accom m odate flush lighting system s, etc.
U sed in conjunction w ith exposed grid suspension
system s.
H old dow n clips are available for areas of fluctuating air
pressure.
Panel Ceiling Systems
NON FIRE RATED
Gyprock

Plasterboard Panels
G yprock

Plasterboard Panels are m achine m ade w ith a


gypsum core and various face treatm ents to suit individual
applications. G yprock

Panels are produced to fit 600 x


1200m m standard grids.
Perforated Panel has a w hite vinyl face finish, and a regular grid
of 6m m full depth holes. Perforations are approxim ately 10% of
the panel area, and com bined w ith suitable insulation, provide a
m edium level of acoustic absorption.
Supatone

is a paper faced w hite ceiling tile suited to basic


com m ercial ceilings. A low m aintenance bright w hite panel, it
can be w iped clean w ith a dam p cloth.
Freshtone

Diamond White has a lightly textured vinyl


surface w hich resists fading and m ould grow th. W ith a
w hite finish, it is suitable for shopping centres, factories and
offices.
1
1
9
1
m
m
1
1
3
0
m
m
590mm
530mm
GYPROCK PERFORATED PANEL
(all dimension nominal)
Gyprock

Ceiling Systems Installation Guide


46
NON FIRE RATED
Ecophon

Ceiling Panels
Ecophon

ceiling panels have a


bonded glassw ool core for high
acoustic perform ance and the Akutex
T finish to provide an attractive easy
care surface.
The range includes:
Focus: 20m m thickness panels w ith a range of edge profiles.
Also available for direct fixing to battens or existing ceiling.
The Akutex T surface is m icro-perforated vinyl paint that can
be easily w iped clean.
Advantage: 15m m thickness panels w ith a glass tissue
facing to m eet general conditions and good acoustic
perform ance.
Master: 40m m thickness panels w ith the highest acoustic
perform ance plus Akutex T finish.
Hygiene: 20m m thickness panels w ith a cleanroom
classification. P rovides excellent acoustic perform ance
and the Akutex T finish is suitable for pressure w ash-dow n
situations.
For detailed inform ation, please refer to the Ecophon
Product C atalogue.
Akutex T
USG Ceiling Panels
U S G ceiling panels have a m ineral fibre core and offer
attractive textured appearance and high acoustic ratings to
m eet the needs of offices, conference room s, boardroom s,
hospitals, cinem as, education, show room s, restaurants, and
hotels. The range includes:
Eclipse ClimaPlus

19m m thick m ineral


fibre panels w ith three
edge options.
H igh N R C values
achieved through
patented technology.
H igh stain resistance
H um idity resistant to
m axim um 95% R .H .
at 40C .
N on-perforated for
a cleaner, lighter
appearance.
Impressions ClimaPlus

15m m thick m ineral


fibre panels w ith three
edge options.
M icro fissured for
a cleaner, w hiter
appearance.
Form ulated to resist
tem perature and
hum idity conditions
up to 40C and 95%
R .H .
N R C 0.50 - 0.60, C AC
33/35 m in for quiet
com fort.
Mars ClimaPlus

19m m thick m ineral


fibre/glassw ool
panels w ith three
edge options.
Sm ooth non-
perforated finish.
U ltra high light
reflectance (90% ).
Form ulated to resist
high tem perature and
high hum idity.
H igh com binations of
N R C and C AC .
Olympia Micro ClimaPlus

15m m thick m ineral


fibre panels w ith three
edge options.
Econom ical, fine-
textured panel.
Excellent light
reflectance reduces
the num ber of light
fixtures needed,
energy usage and eye
strain.
H um idity resistant to
m axim um 95% R .H .
at 40C .
Radar ClimaPlus

15 or 19m m thick
m ineral fibre panels
w ith three edge
options.
True non-directional
texture allow s
installation in any
direction.
A fresh, clean look
adapts to any interior.
Gyprock

Ceiling Systems Installation Guide


47
SYSTEM SPECIFICATION TYPICAL LAYOUT
ACOUSTIC
OPINION
OR
TEST
Refer to
CSR Fricker
R ondo D uo

suspended ceiling system w ith appropriate


acoustic ceiling tiles.
O R
D O N N

suspended ceiling system w ith appropriate


acoustic ceiling tiles
O R
Fricker Easy Access System

w ith appropriate acoustic


ceiling tiles
O R
Plasterboard ceiling or tim ber battens w ith
Ecophon Focus F acoustic ceiling tiles.
Acoustic Panel/Tile Ceiling Systems
Square Tegular Fineline Shiplap Shiplap (F)
CEILING TILE EDGE DETAILS
System CSR 890
w ith Acoustic
C eiling Tile
O ptions
M aterial and
Thickness
Edge
D etails
N R C
C AC
dB
Light
R eflectance
R ecycled
C ontent
W eight
kg/m
2
R Value
Ecophon Focus
A, D , E
G lassw ool
20m m
Square 0.85 21
0.8 70% 2.5 0.61 Shiplap 0.85 25
Tegular 0.9 23
Ecophon Focus F
G lassw ool
20m m
Shiplap(F) 0.75 N A 0.84 70% 2.5 0.61
Eclipse
C lim aPlus
M ineral Fibre
19m m
Square
0.65-0.75 35-39 0.84 78% 5 0.46 Tegular
Fineline
Im pressions
C lim aPlus
M ineral Fibre
15m m
Square
0.50-0.60
33
N AV 38% 3.55 0.33 Tegular 35
Fineline 35
M ars C lim aPlus
M ineral Fibre
& G lassw ool
19m m
Square 0.70-0.80
35-39 0.9 72% 4.7 0.46 Tegular 0.75-0.85
Fineline 0.70-0.80
O lym pia M icro
C lim aPlus
M ineral Fibre
15m m
Square
0.5
30
0.88 52% 4.55 0.33 Tegular 35-39
Fineline 35-39
R adar C lim aPlus
M ineral Fibre
15m m /19m m
Square 0.50-0.60/0.70 33/40
0.84 38% 3.55 0.33 Tegular 0.5-0.6 35
Fineline 0.5-0.6 35
Perforated
Plasterboard (w ith
B radford Anticon
55, foil face up)
Plasterboard
13m m
Square 0.49 N A N A N A 6.5 0.06
N O TES: N A = N ot Applicable N AV = N ot Available
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


48
NON FIRE RATED
300mm
300mm
Tile Hold Down Clip
N703 (optional)
Main Tee
Duo 1/Duo 3
Main
Tee
Wall Angle
Trim
Cross Tee
Duo 4
Cross Tee
1200mm
600mm
600mm
1200mm max.
between suspension
points
GYPROCK plasterboard
or accoustic tile
Practical minimum
150mm
FIG 32: TYPICAL INSTALLATION DETAIL RONDO DUO EXPOSED GRID SUSPENDED CEILING SYSTEM
FIG 33: TYPICAL INSTALLATION DETAIL FRICKER EASY ACCESS SYSTEM

WITH ACOUSTIC CEILING TILES


Top Hat
Main Runner
Top Hat
Main Runner
CSR FRICKER
T5 Light
Wall Angle
Suspension clip and
5mm rod (staggered at
1200mm max. cts)
CSR FRICKER
Ceiling Tile
CSR FRICKER
Ceiling Tile
Back to back
concealed
C-Splines (not
fixed to system)
Top Hat Cross Runner
(every third tile)
Main Runner
Joiner
Gyprock

Ceiling Systems Installation Guide


49
Concrete Slab
Main Tee
CrossTee
Plasterboard or
Acoustic Ceiling
Panel
Wall Angle
Wall Angle
600/1200mm
600mm
600mm
600mm Max.
from wall
Hangers at
1200mm
centres Max.
Donn

Wall Angle
Standard
22mm
19mm
Donn

CL315
Suspension Clip
Donn

Wall Angle
Long
Donn

CL315
Suspension Clip
40mm
19mm
FIG 34: TYPICAL INSTALLATION DETAIL DONN

EXPOSED GRID SUSPENDED CEILING SYSTEM


FIG35: DONN

COMPONENTS FIG 36: DONN

COMPONENTS
Gyprock

Ceiling Systems Installation Guide


50
NON FIRE RATED
TABLE 15: FIRE HAZARD PROPERTIES
C SR G FC Product SM O G R AR C
G roup
N um ber
13m m Perforated Panels 0 1
10m m FR ESH TO N E


D iam ond W hite
0 1
10m m SU PATO N E

0 1
10 13m m U npainted Panel 0 1
U SG Eclipse C lim aPlus 31* 1
U SG Im pressions C lim aPlus 7.4* 1
U SG M ars C lim aPlus 149* 1
U SG O lym pia M icro C lim aPlus 26* 1
U SG R adar C lim aPlus 7.4* 1
Ecophon AD VAN TAG E 0 1
Ecophon FO C U S 0 1
N O TES: SM O G R AR C = Sm oke G row th R ate Index.
* Average Specific Extinction Area
Grid Installation
The follow ing inform ation assum es the room is square and
the ceiling panels are to be installed in a standard square-on-
square pattern. Installation m ethods w ill need to be m odified
to allow for out of square room s or other grid patterns, such
as brick pattern, and to allow for light fittings, etc.
For best appearance, the panels closest to the w alls m ay
need to be cut to size to provide a sym m etrical pattern. To
determ ine the position of the grid, determ ine the num ber
of 1200m m panels that w ill fit the room dim ension.
D eterm ine any rem ainder and add 1200m m . D ivide this
total by 2. This is the m argin along each side of the room .
N ow determ ine the num ber of 600m m panels that w ill fit
the room dim ension. D eterm ine any rem ainder and add
600m m . D ivide this total by 2. This is the m argin at each
end of the room .
Example Grid Calculations:
M ain Tee G rid
4000 1200 = 3.3 m odules
4000 3600 (3 panels) = 400
400 + 1200 = 1600
1600 2 = 800 m argin on each side of the room .
C ross Tee G rid
5000 600 = 8.3 m odules
5000 4800 (8 panels) = 200
200 + 600 = 800
800 2 = 400 m argin at each end of the room .
800
Margin
800
Margin
1200 1200
400 Margin
400 Margin
600
600
600
600
600
600
600
4000
5000
Main
Tee
Cross
Tee
TYPICAL GRID LAYOUT
Design
Considerations
Suspension Systems
G yprock

S uspended C eilings incorporate an Exposed


G rid C eiling S ystem (R ondo D uo

, Fricker Easy A ccess


System

or U SG D onn

), and are designed to AS/N ZS 2785


Suspended C eilings design and installation.
They are not trafficable unless stated, and are designed
to carry the weight of the ceiling only. W here a trafficable
ceiling is required, install a proprietary trafficable ceiling
system .
S trengthen suspension system s to support light fittings
and access panels as show n in the detailing section of this
m anual and/or R ondo technical literature.
Any additional loads are not to be placed upon, or carried
by the suspension system w ithout the approval of R ondo
B uilding Services or C SR G yprock.
Pressure Equalisation Air Grilles
R oom s w hich do not have perm anently open air ventilation
grilles should have grilles fitted in the doors to allow air
pressure to equalise during opening/closing.
If no ventilation grilles are fitted to a room or its doors, C SR
G yprock recom m ends that each panel be held in place w ith
P anel H old-dow n C lips (N 703), to prevent panels lifting
under pressure fluctuations.
Fire Resistance
C SR G yprock ceiling panels have been tested to AS1530.3,
Sim ultaneous determ ination of Ignition, Flam e Propagation,
H eat R elease and Sm oke R elease.
Gyprock

Ceiling Systems Installation Guide


51
Suspension Rod
Main Tee
Suspension Clip
(N700)
Suspension Clip
(N701)
Suspension Rod
Threaded End
Main Tee
Joist
Suspension
Rod N121/122
Suspension
Rod Bracket
N534
Joist
Suspension
Rod N121/122
Suspension
Rod Bracket
N534
Appropriate
masonry fastener
Suspension
Rod
N121/122
Suspension
Rod Angle
Bracket
N547
N702 Direct
Fixing Clip for
Cross Tee
Main
Tee
Install selected w all trim w ith the bottom flange aligned
at the required ceiling level. The ends should be m itre cut
for a m ore attractive finish. Fix trim to the w all fram ing/
m asonry at the ends and at 600m m m axim um centres
betw een.
Accurately position and fix suspension brackets to the
floor/roof structure to support M ain Tees at 1200m m
centres. (Accurate installation is im portant to ensure that
M ain Tees w ill be at 1200m m spacings).
P osition and fix suspension brackets to the floor/roof
structure at 1200m m m axim um centres along the m ain
tees.
Insert rod to suspension brackets and clips.
C ut m ain tees so that the cross
tee slots are ap p rop riately
located to suit the m argin. Install
M ain Tees into the suspension
brackets by squeezing the clip.
Join m ain tees by sliding the self locking end tabs together.
Locate the outer ends of the m ain tees on the w all trim for
stability.
Install the self locking tabs of the cross tees through the
pre-punched slots in the m ain tees and gently push to lock
together form ing a grid of 1200 x 600m m . C ut and install
the outer cross tees on to the w all trim as described for
the m ain tees.
Cross
Tee
locating
slot
Margin tile distance
Suspension Rod
N121
Suspension Clip
(one piece) N700
Suspension Clip
(thread adjustable)
N701
Suspension Rod
Threaded End
N122/123
6
0
0
m
m
m
a
x
.
6
0
0
m
m
m
a
x
.
Suspension
Clip
Squeeze the
clip and insert
the tee
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


52
NON FIRE RATED
Tile Hold-down
Clip N703
GYPROCK
plasterboard panel
or acoustic tile
Tee
FIG 38: PANEL HOLD-DOWN CLIP
Panel
Installation
Clean hands or gloves are essential to prevent soiling
of panel face during installation.
R em ove protective plastic cover from panel face.
Lift the panel through the grid and position face dow n on
the bottom flanges of the grid m ain/cross tees.
Fit H old-dow n C lips to cross tee top flange, and bend
hold-dow n flanges dow nw ard to prevent panels lifting.
Light fittings m ust alw ays be supported on m ain tees.
Additional suspension brackets, rods and clips
MUST BE INSTALLED to support light fittings. R efer
to R ondo literature for m axim um allow able loads for the
grid.
Additional cross tees w ill need to be installed to support
panels at the side of light fittings.
Suspension at
normal spacing
Main Tee
Additional suspension of
main tee to support weight
of light fittings
Additional
Cross Tees to
support cut
panels at side
of light fittings
Light fitting must
be supported on
Main Tees
FIG 37: TYPICAL LIGHT FITTING INSTALLATION
Cross Tee
Cross Tee
Main Tee
Cross Tees
Main Tees
Accurately align and level the grid. The suspension clips
can be adjusted to either a string line or laser.
To assist w ith stabilising the grid system in large ceiling
areas, the W all Trim S tabiliser N 705/706 should be
attached to the w all trim at every second or third m ain
and cross tee.
Wall Trim
Main or Cross
Tee
Stabilising bracket screw
fixed or riveted to wall trim
Partition
Mount Clip
N704
Tee
Partition
R ondo P artition M ount C lip N 704 can be fixed to the
top of the partition fram e to connect the ceiling system to
partitioning.
Gyprock

Ceiling Systems Installation Guide


53
Furring Channel
N129
300mm max.
300mm
max.
Angle Bracket
Bulkhead Support
Clip N717
Main Tee
Main Tee
Bulkhead Trim
Bracing
Rivets
Suspension
Clip
GYPROCK
Ceiling Panel
Suggested Bulkhead Detail
(Maximum Drop 600mm)
FIG 39: HORIZONTAL EXPOSED GRID/VERTICAL SCREW-UP SYSTEM
FIG 40: SUGGESTED RAKED CEILING DETAIL
(Maximum Pitch 45)
Adjustable suspension rod
bracing as and where
required
Main Tee
Suspension Rod N121
Suspension Rod Joiner
N254M
Roof Cladding
Roof Insulation
Hooked
Suspension Rod
Adjustable Suspension
Rod Joiner N254M
NON FIRE RATED
Gyprock

Ceiling Systems Installation Guide


54
Gyprock

Ceiling Systems Installation Guide


55
56
G
Y
P
5
7
0

J
u
n
e

2
0
0
8
Health & Safety
Inform ation on any know n health risks of our products and
how to handle them safely is on their package and/or the
docum entation accom panying them .
Additional inform ation is listed in the M aterial Safety D ata
sheet.
To obtain a copy, telephone 1800 807 668.
Guarantee
C SR B uilding Products guarantees its G yprock

products
to be free of defects in m aterials and m anufacture.
If a C SR product does not m eet our standard, w e w ill, at our
option, replace or repair it, supply an equivalent product, or
pay for doing one of these.
C S R recom m ends that only products, com ponents and
system s recom m ended by it be used. If this is not done,
C SR w ill need to be satisfied that any defect in its product
is attributable to our failure to m eet our standard (and not
another cause) before this guarantee applies.
This guarantee excludes all other guarantees and liability for
dam age or loss in connection w ith defects in C SR 's product,
other than those im posed by legislation.
G yprock , C SR B uilding Products A.B .N . 55 008 631 356.
The follow ing are trade m arks of C SR Lim ited and are under license.
C SR

, G yprock , Supaceil , Soundchek , Aquachek , Im pactchek ,


Fyrchek , Fyrchek M R

, Flam echek M R

, B radford

, designLIN K

Publication G YP570.B M S8952.0608


Contact Details
Gyprock

Web Site
w w w .gyprock.com .au
Gyprock

Sales Support
Telephone: 13 17 44
Facsim ile: 1800 646 364
CSR designLINK

Technical Support Service


Telephone: 1800 621 117
New South Wales and ACT
376 Victoria Street, W etherill Park N SW 2164
Queensland
768 B oundary R oad, C oopers Plains Q LD 4108
Victoria
277 W hitehall Street, Yarraville VIC 3013
South Australia
Lot 100 Sharp C ourt, M aw son Lakes SA 5095
Western Australia
21 Sheffield R oad, W elshpool W A 6106
Tasmania
PO B ox 61, G lenorchy TAS 7010
Northern Territory
C nr Stuart H w y & Angliss St, B errim ah N T 0828

You might also like