Professional Documents
Culture Documents
As approved by Bridges Specifcations and Standards (BSS) Committee of IRC in its third meeting held on
29.05.2013 at New Delhi.
These Errata were prepared and recommended by Concrete (Plain, Reinforced and Pre-Stressed) Structures
Committee (B-4) of IRC and placed before the BSS Committee. The BSS Committee in its third meeting held
on 29.05.2013 approved these Errata.
These Errata are also available on IRC Website for wider circulation and beneft of the Highway professionals.
Sl. No. Clause No. &
Page No.
As written in the code : To be read as :
1. 3.1.3 (Page 8) Reference Period/Return Period Reference Period
2. 3.1.3 (Page 8) Quasi Permanent Value of Variable Action (
2
Q
k
)
Value determined so that the ..using factor
2
1
Quasi Permanent Value of Variable Action (
2
Q
k
)
Value of a variable action as a fraction of characteristic load,
which is present for substantial part of the reference period.
3. 3.2.2 (Page 13) New Addition after z Lever arm of Internal forces n Exponent forstrain in concrete stress block
4. 5.8.4 (Page 26) The permissible limits of known harmful elements in
acceptable and durable materials are specifed in Section
18
The permissible limits of known harmful elements in
acceptable and durable materials are specifed in Section 14
5. 6.3.5 2
nd
line
from top
(Page 34)
(
pk
, f
pk
) (
uk
, f
pk
)
6. Table 6.5,
Sr. No. 3
(Page 38)
Conc.
Grade
M65 M70 M75 M80 M85 M90
f
ctm
(Mpa)
4.1 4.3 4.4 4.5 4.7 4.8
Conc.
Grade
M65 M70 M75 M80 M85 M90
f
ctm
(Mpa)
4.4 4.5 4.7 4.8 4.9 5.0
7. Table 6.5,
Sr. No. 11,
(Page 38)
n
8. 6.4.2.2 (1)
Defnition of
term S,
(Page 39)
S = Co-effcient whose value is taken as 0.25 for normal
Portland and rapid hardening cement. Refer ...
S = Co-effcient whose value is taken as 0.25 for ordinary
Portland cement. Refer ...
9. 6.4.2.2 (2)
6
th
line
(Page 39)
...long term in-structure compressive strength is taken as
0.67 times 28 days cube strength
...long term compressive strength in structure is taken as
0.67 times 28 days cube strength
10. 6.4.2.3 (1)
2
nd
Para
(Page 40)
The co-relation between mean tensile ... The relation between mean tensile ...
11. Eq. 6.9
(Page 42) = (t, to) =
cc t
ci to
( )
( )
= (t, to) =
cc t
ci to
( )
( )
12. 6.4.2.5 (2)
(Page 43),
1
st
Para
The shrinkage & creep strains are to be estimated as given
in Clauses 6.4.3.6 and 6.4.3.7
The shrinkage & creep strains are to be estimated as given in
Clauses 6.4.2.6 and 6.4.2.7
13. 6.4.2.5 (4) (i)
(Page 43),
3
rd
line
(slope of line connecting the origin to stress/strain diagram
to 0.4 f
cm
)
(slope of line connecting the origin to stress/strain diagram
to 0.33 f
cm
)
ERRATA TO :
IRC:112-2011 CODE OF PRACTICE FOR CONCRETE ROAD BRIDGES
ERRATA TO IRC:112-2011 'CODE OF PRACTICE FOR CONCRETE ROAD BRIDGES'
INDIAN HIGHWAYS, AUGUST 2013 63
Sl. No. Clause No. &
Page No.
As written in the code : To be read as :
14. Table 6.8, Title
(Page 46)
Unrestrained Drying Shrinkage Values (
ca
10
6
) Unrestrained Drying Shrinkage Values (
cd
10
6
)
15. Eq. 6.12
(Page 46)
ca
(t) =
as
(t).
cw
ca
(t) =
as
(t).
cw
16. 6.4.4.2.7, 3
rd
line
(Page 46)
...In addition to the factors listed in Clause 6.4.3.6(1) ...In addition to the factors listed in Clause 6.4.2.6(1)
17. 6.4.2.7 (2)
(Page 47)
New addition after last line "...increased by 10 percent in
absence of accurate data."
"...increased by 10 percent in absence of accurate data. In
case the compressive stress exceeds 0.36fck, at loading, non-
linear creep shall be considered."
18. Eq. 6.21,
(Page 49)
c cd
c
c
f =
|
\
|
.
|
(
(
1 1
2
where
=Exponent as given in Table 6.5
o
c
c
n
c cd
c
c
f =
|
\
|
.
|
(
(
1 1
2
where
n =Exponent as given in Table 6.5
19. 7.1.7 (4),
5
th
line
(Page 53)
In the absence of other data, v may be taken as 0.6,
including an allowance for sustained loading.
In the absence of other data, v may be taken as 0.6,
including an allowance for sustained loading.
20. 7.3 (2)
(Page 54)
Where required (e.g. in seismic analysis), plastic method
of analysis (e.g. plastic hinges for linear members or
yield line for slabs/walls) may be used provided it ... local
plastically.
In seismic analysis, plastic method of analysis may be used
provided it... local plastically.
21. 7.7.1 (5),
6
th
line
(Page 59)
"...The time dependent laws of shrinkage and creep
given..."
The time dependent properties of shrinkage and creep
given.
22. Eq. 7.3
Reduction
Coeffcient,
(Page 59)
=(l-e
)/ =(1-e
(-)
/
23. 7.9.6
1
st
Para
(Page 66)
The requirement of minimum concrete strength (f
c.str
)
behind the anchorage of post tensioned system, at the time
of stressing, shall be specifed by the designer ...
The requirement of minimum concrete strength behind the
anchorage of post tensioned system, at the time of stressing,
for full jacking force, designated as f
c.str
shall be specifed by
the designer
24. 7.9.6 Below
2
nd
para
(Page 66)
- For 100% tendon force, minimum strength is f
c.str
- For 30% tendon force, minimum concrete strength is
0.5 f
c.str
- Between 30% and 100% of tendon force, minimum
Concrete strength shall be arrived at by linear interpolation
between 0.5 f
c.str
& f
c.str
- For 100% jacking force, minimum concrete strength is f
c.str
- For 30% jacking force, minimum concrete strength is
0.5 f
c.str
- Between 30% and 100% of jacking force, minimum concrete
strength shall be arrived at by linear interpolation between
0.5 f
c.str
& f
c.str
25. 7.10.2, Fig. 7.2
(Page 67)
Where Vc =0.13.l.d
eff
.f
ck
(in SI units) Where Vc =0.13.l.d
eff
.(f
ck
)
0.5
(In SI units)
26. 7.10.3, Line 4
Radial Reinft.
(Page 68)
These tensions should be resisted by reinforcement
forming full loops or 180 hooks (Fig. 15.2(d) with 180
bend) placed in the ...
These tensions should be resisted by reinforcement forming
full loops or 180 hooks (Fig. 15.2(e) with 180 bend) placed
in the
27. 8.2.1, (1) (k),
3
rd
line
(Page 71)
nutral neutral
28. 8.2.1, (2)
(Page 71)
For values of deformation charactreristics of concrete such
as,
c2
,
cu2
refer Table 6.7
For values of deformation charactreristics of concrete such
as,
c2
,
cu2
refer Table 6.5
ERRATA TO IRC:112-2011 'CODE OF PRACTICE FOR CONCRETE ROAD BRIDGES'
64 INDIAN HIGHWAYS, AUGUST 2013
Sl. No. Clause No. &
Page No.
As written in the code : To be read as :
29. Clause 8.2.2
Fig. 8.2
(Page 72)
Fig. 8.2 Domains of Strain Distributions
Fig. 8.2 Domains of Strain Distributions
30. 8.2.2 Zone 2,
last line
(Page 73)
The tensile strain at steel exceeds
ud
. The tensile strain at steel is at the upper design limit of
ud
.
31. 8.3.2 (4)
Eq. 8.3
(Page 75)
M
M
M
M
Edx
Rdx
a
Edy
Rdy
a
|
\
|
.
|
+
|
\
|
.
|
|
M
M
M
M
Edx
Rdx
Edy
Rdy
|
\
|
.
|
+
|
\
|
.
|
|
1
32. Fig. 10.1(a)
Page 81
B - Web shear creack zone
C - Flexural shear creack zone
B - Web shear crack zone
C - Flexural shear crack zone
33. Clause 10.2.2.1,
3
RD
para
(Page 81)
'
sup
' & ''
inf
'
max
&
min
1
(Page 87)
1
=A
s
/b
w
.d 0.02
1
=
A
b d
sl
w.
0.02
39. 10.3.1
Notation for
cp
(Page 87)
"The value of Scp need not be calculated at a distance less
than 0.5d cotq..."
"The value of
cp
need not be calculated at a distance less
than 0.5d cot ..."
40. 10.3.2 (5)
(Page 89)
The term '
v
' in line 1,2,4,7 'a
v
' in line 1,2,4,7
41. 10.3.2 (5)
eq. 10.6
(Page 90)
v =0.6 x [1-f
ck
/310] f
ck
in Mps v =0.6 x [1-f
ck
/310], where f
ck
is in Mpa
42. 10.3.3.2
Value of Z",
(Page 91)
Z lever arm can be taken as 0.9 for RCC section and to
be calculated for PSC section.
Z lever arm can be taken as 0.9d for RCC section and to be
calculated for PSC section.
43. 10.3.3.3 (5)
(Page 92)
Where the web contains grouted ducts with a diameter
<b
w
/8 the shear resistance ...
Where the web contains grouted ducts with a diameter
<b
w
/8 the shear resistance ...
44. 10.3.3.3 (7)
(Page 93)
The term '
v
' in line 2,3 'a
v
'
45. 10.3.3.3 (8)
(Page 93)
0.75
v
0.75a
v
46. 10.3.5
Fig. 10.9
(Page 97)
'A
st
', '' and 'S
t
'. 'A
sf
', '
f
' and 'S
f
' respectively
47. 10.3.5 (2)
(Page 98)
V
Ed
f
cd
sin
f
cos
f
V
Ed
<f
cd
sin
f
cos
f
48. 10.4.3 (5),
3
rd
Line,
(Page 103)
Fig. 10.14(b) Fig. 10.13(b)
49. 10.4.6 (3), (a)
(Page 105)
Where u
o
- for an inner column =length of column,
Periphery in mm.
- for edge column =(mm)
- for corner column =
Where u
o
:
- for an inner column =length of column,
periphery in mm.
- for edge column =C
2
+3d C
2
+2C
1
(mm)
- for corner column = 3d C
1
+C
2
(mm)
50. Clause 10.5.1
(3)-Last Para
(Page 106)
It will not normally be unnecessary to consider torsion at
ultimate limit state [Fig. 10.14(b)]
It will not be necessary to consider torsion at ultimate limit
state [Fig. 10.14(b)]
51 11.3.2.2 (3)
4
th
line after
Eq. 11.6
(Page 116)
l/
r
is the curvature, see clause 11.3.2.3 l/r is the curvature, see clause 11.3.2.3
52. Clause 11.3.4:
Biaxial
Bending
(Page 118)
Clause 11.3.4 Clause 11.3.3
53. 12.23.1
Last Line
(Page 121)
...need to be controlled by measures given under Clause
14
...need to be controlled by measures given under Section 14
ERRATA TO IRC:112-2011 'CODE OF PRACTICE FOR CONCRETE ROAD BRIDGES'
66 INDIAN HIGHWAYS, AUGUST 2013
Sl. No. Clause No. &
Page No.
As written in the code : To be read as :
54. 12.3.3 (2)
Line below
Eq. 12.3
(Page 124)
S
c
is the mean stress of the concrete acting on the part of
the section under consideration:
c
is the mean stress of the concrete acting on the part of the
section under consideration:
55. 12.3.4 (2)
Defnition of
"h
c,efff
",
(Page 126)
A
c,eff
is the effective area of concrete in tension surrounding
the reinforcement, of depth h
c,eff
where h
c,eff
, is the lesser of
2.5(h-d); (h-x/3); or h/2 (refer Fig. 12.2).
A
c,eff
is the effective area of concrete in tension surrounding
the reinforcement, of depth h
c,eff
where h
c,eff
, is the lesser of
2.5(h-d); (h-x)/3; or h/2 (refer Fig. 12.2).
56. 12.3.4 (3)
Eq. 12.8
(Page 127)
34 0425
1 2
. .
.
c k k
eff
+
3.4c +
0425
1 2
.
.
k k
eff
a
0.7 for bent bars in tension, if the concrete cover
perpendicular to ..."
a
0.7 for bent bars and loop bars in tension, if the concrete
cover perpendicular to ..."
68. Clause
15.2.5.1
Fig. 15.5
Page (156)
Fig. 15.5 Detailing of Transverse Reinforcement at
Lapped-Splices
Fig. 15.5 Detailing of Transverse Reinforcement at Lapped-
Splices
69. Clause
15.2.7.2
Fig. 15.7
Page (161)
Fig. 15.7 Anchorage of Bundles of Bars
Fig. 15.7 Anchorage of Bundles of Bars
70. 15.3.2.2(2) (c)
(Page 167)
The design-value-of the-transmission length should be
taken as-the less favourable-of the two values, depending
on the design situation.
l
pt1
=0.8l
pt
Eq. 15.9
l
pt1
=1.2l
pt
Eq. 15.10
Note: Normally the lower value is used for verifcation of
local stresses at release, the higher value for ultimate limit
states (shear, anchorage etc.).
The design value of the transmission length should be taken
depending on the design situation, given in Eq. 15.9 or
15.10.
l
pt1
=0.8l
pt
Eq. 15.9
l
pt2
=1.2l
pt
Eq. 15.10
Note: The lower value is used for verification of local stresses
at release, the higher value for ultimate limit states (shear,
anchorage etc.).
71. 15.3.2.2 (3) (a)
(Page 168)
The tendon forces should be calculated for a cracked
section, including the effect of shear according to Clause
10.3.3.2 (5)
The tendon forces should be calculated for a cracked section,
including the effect of shear according to Section 10.3.3.3(6)
72. Eq. 15.13
(Page 168)
l
bpd
=l
pt2
+
2
(
pd
-
pm,)/fbpd
l
bpd
=l
pt2
+
2
(
pd
-
pm,
)/f
bpd
73. 15.3.2.2 (3) (d)
4
th
& 5
th
line
below Eq.
15.13
(Page 168)
pd
is the tendon stress corresponding to the force
described in (a)
pm
.
pd
is the tendon stress corresponding to the force
described in (a)
pm
.
w
SW
w
A
s b
=
. sin
w
SW
w
A
s b
=
. sin
79. Clause
16.6.1.1
Fig. 16.5
(Page 182)
Fig. 16.5 Provision of Reinforcing Bars Fig. 16.5 Provision of Reinforcing Bars
80. Line below
16.6.2 (4)
(Page 185)
The maximum longitudinal spacing of successive series of
links is given by:
(5) The maximum longitudinal spacing of successive series
of links is given by:
81. 16.12,
Last Line
(Page 189)
Refer Clause 7.11.2 for requirements of curved tendons. Refer Clause 7.10.1 for requirements of curved tendons.
ERRATA TO IRC:112-2011 'CODE OF PRACTICE FOR CONCRETE ROAD BRIDGES'
INDIAN HIGHWAYS, AUGUST 2013 69
Sl. No. Clause No. &
Page No.
As written in the code : To be read as :
82. Clause 16.13
Fig. 16.11
(Page 190)
Fig. 16.11 Extent of the Inter-Section Zone (in Plan) for
the Connection of Secondary Beams
Fig. 16.11 Extent of the Inter-Section Zone (in Plan) for the
Connection of Secondary Beams
83. Clause
17.2.1.4
Fig. 17.2
(Page 196)
Fig. 17.2 Typical Confnement Detail in Concrete Piers
with Rectangular Section using Overlapping Rectangular
Stirrups and Cross-Ties
Fig. 17.2 Typical Confnement Detail in Concrete Piers with
Rectangular Section using Overlapping Rectangular Stirrups
and Cross-Ties
84. 17.2.2 (2) (a),
5
th
line
(Page 197)
Bends of 90 are not permitted if
k
is less than 0.3 Bends of 90 are not permitted if
k
is greater than 0.3.
85. 17.2.4 (3),
second line,
(Page 198)
.the ratio h
k
does not exceed 0.2, there is no need for
verifcation.
.the ratio
k
does not exceed 0.2, there is no need for
verification.
86. 18.7.4 (7)
(Page 216)
within the range of 0 percent and 0.1 percent of the
original volume. It should not be more than +0.2 percent
at 28 days.
within the range of -0.5 percent and 5.0 percent of the
original volume.
87. Clause A1-4 (2)
(a), 3
rd
line
(Page 234)
These are the persistent situations Delete this sentence
ERRATA TO IRC:112-2011 'CODE OF PRACTICE FOR CONCRETE ROAD BRIDGES'
70 INDIAN HIGHWAYS, AUGUST 2013
Sl. No. Clause No. &
Page No.
As written in the code : To be read as :
88. Eq. A2-5
(Page 236) E
cm
=22
f
cm
125
03
.
.
|
\
|
.
|
E
cm
=22
f
cm
125
03
.
.
|
\
|
.
|
, E
cm
in GPa
89. Eq. A2-10
(Page 236) =1.4+23.4
90 08
100
4
(
. f
ck
n =1.4+23.4
90 08
100
4
(
. f
ck
90. ANNEXURE
A-2
CLAUSE A2.5,
Eq. A2-17
(Page 238)
for f
cm
45 Mpa for f
cm
>45 Mpa
91. ANNEXURE
A-2
CLAUSE A2.5,
defnition of
(t
o
)
(Page 238)
is a factor to allow for the effect of concrete age at loading
on the notional creep coeffcient (Refer Note No.1)
is a factor to allow for the effect of concrete age at loading on
the notional creep coefficient.
92. ANNEXURE
A-2
CLAUSE A2.5,
Eq. A2-22
(Page 238)
for f
cm
35 for f
cm
45 Mpa
93. ANNEX A-2
CLAUSE A2.5,
Eq. A2-23
(Page 239)
for f
cm
35 for f
cm
>45 Mpa
94. ANNEX A-2
Clause A2.8
Fig. A2-2
(Page 242)
Fig. A2-2 Stress-Strain Relationship for Confned
Concrete
Fig. A2-2 Stress-Strain Relationship for Confned Concrete
OBITUARY
The Indian Roads Congress express their profound sorrow on the sad demise of Shri Ramesh Chandra
J indal, resident of 4/54, Vishal Khand, Gomti Nagar, Lucknow. He was an active member of the
Indian Roads Congress.
May his soul rest in peace.