You are on page 1of 2

Category 6 Cable

1427071-2, 1427071-4, 1427071-6

5.6 NOM
CONDUCTOR
INSULATION
CORE : 4 PAIRS, 1 FILLER
CABLED TOGETHER

PAIRS TWISTED WITH


DIFFERENT LAYS

JACKET
RIPCORD

Description
AMP NETCONNECT Category 6 (CAT6) cables exceed TIA/EIA-568-B.2-1 and ISO/IEC 11801:2002
Class E, IEC61156-5, IEC60332-1-2, EN50288-6-1 and EN50173-1 performance requirements, They
comply with all of the performance requirements for current and proposed applications such as
Gigabit Ethernet, 100BASE-Tx, token ring, 155 Mbps ATM, 100 Mbps TP-PMD, ISDN, analog
(Broadband, Baseband) and digital video and analog and digital voice (VoIP). The cable is available in
white, gray, and blue, and packaged as reel-in-box.

Specification (Text in brackets [ ] requires a choice.)


Horizontal cabling shall be 24 AWG, 4-pair UTP, UL/NEC CM rated, with a [white, gray or blue]
[CM] PVC jacket. Cable shall meet the performance requirements listed in the following table
[include Performance Characteristics table from back page]. Cable shall be AMP part number
[1427071-X].

Description

4-Pair Non-Plenum

UL/NEC Nominal Diameter


Ratings Dielectric Outside
CM

Package: Reel Box (1000 ft.)

0.037 in 0.220 in

Vp
(nom%)

Weight

70

26 lbs/mft

Part Numbers

Package
Reel
Box

White

Gray

Blue

1427071-2

1427071-4

1427071-6

Category 6 Cable

1427071-2, 1427071-4, 1427071-6

Performance Characteristics (exceed TIA/EIA-568-B.2-1Category 6)


Frequency
(MHz)

Attenuation
(dB/100m)

NEXT
(dB)

PSNEXT
(dB)

ELFEXT
(dB)

PSELFEXT
(dB)

RL
(dB)

ACR
(dB)

PSACR
(db)

Max

Min

ETL

Min

ETL

Min

ETL

Min

ETL

Min

ETL

Min

ETL

Min

ETL

0.772
1
4
8
10
16
20
25
31.25
62.5
100
200
250

1.63
1.83
3.62
5.09
5.69
7.15
8.00
8.96
10.03
14.30
18.23
26.12
29.32

79
74.3
65.3
60.8
59.3
56.2
54.8
53.3
51.9
47.4
44.3
39.8
38.3

96.81
93.56
87.21
84.84
81.35
75.46
77.46
74.39
73.62
67.53
63.74
63.23
58.28

77
72.3
63.3
58.8
57.3
54.2
52.8
51.4
49.9
45.4
42.3
37.8
36.4

94.11
91.99
84.85
81.90
78.54
74.42
74.80
72.18
70.87
65.99
62.35
60.66
55.37

70
67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
21.8
19.8

92.02
89.73
80.15
74.93
72.84
69.35
66.21
63.95
61.34
55.28
53.39
42.22
38.45

67
64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
18.8
16.8

90.99
88.68
78.23
72.74
70.72
66.19
63.61
61.63
59.43
53.62
51.68
41.38
38.02

20
23
24.5
25
25
25
24.3
23.6
21.5
20.1
18
17.3

36.55
32.04
35.31
32.93
33.30
34.21
33.31
33.40
34.05
33.98
35.98
32.75
37.17

77.2
72.3
61.5
55.5
53.3
48.7
46.3
43.9
41.2
32.0
24.5
10.8
5.6

95.18
91.73
83.59
79.79
75.71
68.31
69.53
65.49
63.58
53.23
45.51
37.57
29.14

75.2
73
62.2
56.7
54
49.4
47.5
44.5
42.3
32.6
25.2
12
6.2

92.48
90.16
81.23
76.89
72.93
67.27
66.95
63.38
60.97
51.87
44.12
34.59
26.48

Technical Details
Materials
Conductors
Insulation
Jacket
Filler

24 AWG solid bare copper


Polyethylene, 0.037 in nom dia
FR PVC,CM
Polyethylene

Electrical Characteristics
Impedance
Propagation delay
Skew
Mutual capacitance
Conductor resistance
Mechanical Characteristics
Bend radius
Operating temperature
Storage temperature

100 15%, 1 MHz to 250 MHz


536 ns/100 m max. @ 250 MHz
45 ns/100 m max. @250 MHz
5.6 nF max/100 m
66.58 max/1000 m
The minimum bending radius is 8x outside diameter during installation and 4x
the outside diameter after installation 1"
-20C to 60C
-20C to 80C

Approvals
UL File Number E138034
ETL Certificate
RoHS Compliant

3162341CRT-001

Specifications subject to change without notice.


http://www.ampnetconnect.com/thailand

Revised 03/09

You might also like