You are on page 1of 6

January 2004

CA03701001E For more information visit: www.eatonelectrical.com


11
Lighting Contactors
Enclosed Control
C30CN Enclosed
Contents
Description Page
Enclosed Control
Product Description . . . . . . . . 11
Application Description. . . . . 11
Technical Data and
Specications . . . . . . . . . . . 11
Standards and
Certications . . . . . . . . . . . . 11
Accessories. . . . . . . . . . . . . . . 11
Dimensions. . . . . . . . . . . . . . . 12
Catalog Number
Selection . . . . . . . . . . . . . . . 15
Product Selection. . . . . . . . . . 15
Modication Codes . . . . . . . . 17
Enclosed Lighting Contactors
Product Description
Cutler-Hammer

Enclosed Lighting
Contactors by Eaton Electrical

are
designed to provide a safe, convenient
means for local or remote switching of
tungsten (incandescent and lament)
and ballast (uorescent and mercury
arc) lamp loads. They are also suitable
for other loads such as low pressure
and high pressure sodium lamp loads
and other non-motor (resistive) loads.
They are not recommended for most
sign ashing loads.
The C30CN lighting contactors are
designed to withstand the large initial
inrush currents of tungsten lamp loads
without contact welding. They are fully
rated to 30 amps and do not require
derating.
Application Description
Ballast Lamps Fluorescent, Mer-
cury Vapor, Metal Halide Sodium
Vapor, Quartz 600 Volt maximum
Filament Lamps Incandescent,
Infrared, Heating 480V maximum,
line to line; 277V maximum line to
neutral
Resistance Heating Radiant and
convection heating, furnaces and
ovens
Technical Data and Specications

Table 22. NEMA 1 Enclosed Non-combination Lighting Contactors C30CN


Table 23. NEMA 3R, 4X and 12 Enclosed Non-combination Lighting Contactors C30CN

Consult factory for combination enclosures.


Standards and Certications
UL Listed File number E44424,
Guide Number NRNT
CSA Certied
Accessories
Auxiliary Contacts
The base C30CN product line can
accept up to four auxiliary contacts
(2NO/2NC), which are mounted on the
top of the unit. The auxiliary contacts,
rated A600 are also suitable for use on
low-level circuits down to 12V, 5 mA.
Power Poles
The C30CN can be congured with up
to 12 poles (30A maximum per pole).
Power poles are available in single or
double pole designs and can be
mounted to provide either normally
open or normally closed operation
with a maximum of 12 NO poles or 8
NC and 4 NO poles. Each pole is capa-
ble of accepting up to 8 AWG wire.
Mechanically Held Kit
A modication kit allows the conver-
sion of an electrically held lighting
contactor into a mechanically held
contactor.
2-Wire or 3-Wire Control Module
A mechanical latch with a 2- or 3-wire
electronic control module delivers reli-
able performance and protection from
such application abnormalities as line
noise, leakage currents from controller
outputs, or short repetitive commands
burst from faulty controllers. For
Enclosed Control, units come standard
with 2-wire control.
IMPORTANT: Add the C18 Modication
code to get 3-wire control with the
C30CN contactor.
Coil Kits
The C30CN line comes in a wide range
of input voltages and with coils from
24V AC to 600V AC.
Ampere Size Poles Box No. Shipping Weight
Lbs. (kg)
Lighting Contactors without Control Power Transformers
30A 2 12 2 9 (4.1)
Lighting Contactors with Control Power Transformers
30A 2 12 3 13.5 (5.9)
Ampere Size Poles Box No. Shipping Weight
Lbs. (kg)
Lighting Contactors without Control Power Transformers
30A 2 12 6 14 (6.4)
Lighting Contactors with Control Power Transformers
30A 2 12 7 20 (9.1)
January 2004
12
For more information visit: www.eatonelectrical.com CA03701001E
Lighting Contactors
Enclosed Control
Type C30CN Enclosed Dimensions
Cover Mounted Pilot Devices
Table 24. Cover Mounted Pilot Devices

For use with Non-combination units (Box sizes 1 4).

For use with NEMA 1 Combination units.

Selector Switch.

Add Code Letter from table below to Catalog Number for Voltage in
place of _.
Dimensions
Figure 6. Box 2, NEMA 1 Approximate Dimensions in Inches (mm) Figure 7. Box 3, NEMA 1 Approximate Dimensions in Inches (mm)
Description For use with
C30C Lighting
Contactor
NEMA 1 Field
Installation Kits

NEMA 3R, 4X, 12 Field


Installation Kits

NEMA 1, 3R, 4X & 12


Factory Installed Cover
Control
NEMA 7/9 Factory
Installed Cover Control
Catalog
Number
Price
U.S. $
Catalog
Number
Price
U.S. $
Modication
Code Sufx
Adder
U.S. $
Modication
Code Sufx
Adder
U.S. $
ON/OFF Pushbuttons
with Red RUN Pilot Light
with red RUN/GREEN off lights
Electrical
3-wire control
C400GK18
C400GK19_
C400GK1A_
62.00
176.00
285.00
C400T2

61.50

P8
P8P23
P8P23P25
171.00
342.00
513.00
P8
P8P23
P8P23P25
312.00
625.00
937.00
ON/OFF Pushbuttons
with Red RUN Pilot Light
with red RUN/GREEN off lights
Mechanical
3-wire control
C400GK4
C400GK48_
C400GK49_
62.00
176.00
285.00
C400T201

61.50

P8
P8P23
P8P23P25
171.00
342.00
513.00
P8
P8P23
P8P23P25
312.00
625.00
937.00
ON/OFF Pushbuttons
with Red RUN Pilot Light
with red RUN/GREEN off lights
Elec. & Mech.
2-wire control
C400GK5
C400GK52_
C400GK55_
62.00
176.00
285.00
C400T14

61.50

P8
P8P23
P8P23P25
171.00
342.00
513.00
P8
P8P23
P8P23P25
312.00
625.00
937.00
Start/Stop Pushbuttons
with Red RUN Pilot Light
with red RUN/GREEN off lights
Mechanical
3-wire control
C400GK7
C400GK72_
C400GK75_
62.00
176.00
285.00
C400T200

61.50

P7
P7P23
P7P23P25
171.00
342.00
513.00
P7
P7P23
P7P23P25
312.00
625.00
937.00
Start/Stop Pushbuttons
with Red RUN Pilot Light
with red RUN/GREEN off lights
Elec. & Mech.
2-wire control
C400GK6
C400GK62_
C400GK65_
62.00
176.00
285.00
C400T13

61.50

P7
P7P23
P7P23P25
171.00
342.00
513.00
P7
P7P23
P7P23P25
312.00
625.00
937.00
HAND/OFF/AUTO Cover Control
with Red RUN Pilot Light
with red RUN/GREEN off lights
Elec. & Mech.
2-wire control
C400GK3
C400GK32_
C400GK35_
62.00
176.00
285.00
C400T12

61.50

S3
S3P23
S3P23P25
171.00
342.00
513.00
S3
S3P23
S3P23P25
312.00
625.00
937.00
Red RUN Pilot Light
Green OFF Pilot Light
Red RUN/Green OFF Pilot Light
All C400GK42_
C400GK41_
C400GK46_
115.00
115.00
228.00
C400T9_
C400T10_
C400T11_
122.00
122.00
228.00
P23
P25
P23P25
171.00
171.00
342.00
P23
P25
P23P25
312.00
312.00
625.00
Rating Code Letter Rating Code Letter
24V 60 Hz
120V 60 Hz
208V 60 Hz
240V 60 Hz
T
A
E
B
277V 60 Hz
380V 60 Hz
480V 60 Hz
600V 60 Hz
H
L
C
D
7.73 (196.3) Max.
3.81
(96.8)
.16
(4.1)
.16
(4.1)
11.08
(281.4)
13.21
(335.5)
Max.
12.60
(320.0)
Max.
3.25
(82.6)
1.38
(35.1)
1.44
(36.6)
1.44
(36.6)
6.00
(152.4)
2.00
(50.8)
2.44
(62.0)
1.54
(39.1)
.22 (5.6) Dia. Mtg. Holes for
(3) #10-32 Screws
5.84
(148.3)
Max.
6.75 (171.5) Max.
to Optional
Cover Controls
Concentric Knockouts
for 1/2" & 3/4" Conduit
(1) Each Top & Bottom.
Concentric
Knockouts
for 1/2", 3/4" &
1" Conduit
(2) Each Side
Concentric Knockouts
for 1" & 1-1/4" Conduit
(2) Each Top & Bottom.
.92
(23.4)
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD-1C
12.65 (321.3) Max.
9.75 (247.7)
1.48 (37.6)
1.28
(32.5)
.16 (4.1)
11.25
(285.8)
14.40
(365.8)
Max.
13.85
(351.8)
Max.
2.43
(61.7)
1.46
(37.1)
2.43
(61.7)
6.60
(167.6)
1.51
(38.4)
.28 (7.1) Dia. Mtg. Holes
for (4) 1/4-20 Screws
6.40 (162.6)
7.31 (185.7)
to Optional
Cover Controls
Concentric Knockouts for
1/2" & 3/4" Conduit
(1) Each Top & Bottom.
Concentric Knockouts for
1/2" & 3/4" Conduit
(2) Each Side
Concentric Knockouts
for 3/4", 1" & 1-1/4" Conduit
(2) Each Top & Bottom.
January 2004
CA03701001E For more information visit: www.eatonelectrical.com
15
Lighting Contactors
Enclosed Control
C30CN Enclosed Product Selection
Catalog Number Selection
Table 25. Enclosed Control Lighting Contactors Catalog Numbering System

For normally closed poles, see Table 34 on Page 18.


Product Selection
Enclosures
Lighting contactors are available open
or mounted in NEMA Type 1, 3R, 4X,
12 or 7/9 enclosures.
NEMA 1 is for indoor, general purpose
for personal protection. Knock-outs
are provided in the top and bottom for
conduit entry.
NEMA 3R is for outdoor applications
and rated for rain, sleet and external
ice buildup. NEMA 3R enclosures have
knockouts in the bottom and provi-
sions for a hub in the top.
NEMA 4X is for mounting indoor or
outdoor and provides protection from
splashing water, hose-directed water
and wind-blown dust. Watertight con-
duit hubs are provided in the top and
bottom of NEMA 4X enclosures. The
standard NEMA 4X enclosures are
made of stainless steel 304 material,
providing corrosion protection.
NEMA 12 enclosures are for indoor
mounting and protect from dripping
liquids, falling dirt and dust. No knock-
outs or hubs are provided with NEMA
12 enclosures.
NEMA 1, 3R and 12 enclosures are
painted with a polyester urethane
powder coat paint meeting UL require-
ments and the color is ANSI 61 gray.
NEMA 1 enclosures have knockouts
for cover controls. All the other NEMA
types have holes plugged, ready for
cover controls. NEMA 7/9 is also avail-
able for explosion proof applications.
Please contact the factory for addi-
tional details.
E C C 0 3 C 1 B 8 A
EC = Enclosed Control
Magnetic Coil Selection
A = 120/60 or 110/50
B = 240/60 or 220/50
C = 480/60 or 440/50
D = 600/60 or 550/50
E = 208/60
H = 277/60 or 240/50
T = 24/60
V = 28/60 or 24/50
X = 347/60
Design
C = C30CN Lighting Contactor
Class
03 = Electrically Held, Non-combo
04 = Mechanically Held, Non-combo
12 = Elect. Held w/ Fusible Disconnect
13 = Mech. Held w/ Fusible Disconnect
14 = Elect. Held w/ Circuit Breaker
15 = Mech. Held w/ Circuit Breaker
Max. Ampere Rating
C = 30 Amps
Enclosure Type
1 = NEMA 1 General Purpose
2 = NEMA 3R Rainproof
4 = NEMA 4X Watertight Stainless Steel
6 = NEMA 7/9 Explosion Proof
8 = NEMA 12 Dust-Tight
Total Number of Poles

2 = 2-pole
3 = 3-pole
4 = 4-pole
5 = 5-pole
6 = 6-pole
7 = 7-pole
8 = 8-pole
9 = 9-pole
A = 10-pole
B = 12-pole
Disconnect Fuse
Clip Rating
HMCP or
Breaker Rating
A = None
B = 30A/ 250V R
C = 30A/ 600V R
D = 60A/ 250V R
E = 60A/ 600V R
F = 100A/ 250V R
G = 100A/ 600V R
T = By Description
A = None
B = 3A
C = 7A
D = 15A
E = 30A
F = 50A
G = 100A
T = By Description
January 2004
16
For more information visit: www.eatonelectrical.com CA03701001E
Lighting Contactors
Enclosed Control
C30CN Enclosed Product Selection
AC Lighting Contactors 2-Wire Control Standard
Table 26. Class ECC03 Non-combination Electrically Held 2-Wire Control

Add C18 Modication Code for 3-wire control.

For rst open position (Coil Voltage), use the table below.
Table 27. Class ECC04 Non-combination Mechanically Held 2-Wire Control

Add C18 Modication Code for 3-wire control.

For rst open position (Coil Voltage), use the table below.
Number of
Poles
NEMA 1 NEMA 3R NEMA 4X NEMA 7/9 NEMA 12
Catalog
Number

Price
U.S. $
Catalog
Number

Price
U.S. $
Catalog
Number

Price
U.S. $
Catalog
Number

Price
U.S. $
Catalog
Number

Price
U.S. $
Continuous Amps 30
2 ECC03C1_2A 295. ECC03C2_2A 380. ECC03C4_2A 545. ECC03C6_2A 1,610. ECC03C8_2A 380.
3 ECC03C1_3A 360. ECC03C2_3A 445. ECC03C4_3A 610. ECC03C6_3A 1,670. ECC03C8_3A 445.
4 ECC03C1_4A 415. ECC03C2_4A 500. ECC03C4_4A 665. ECC03C6_4A 1,720. ECC03C8_4A 500.
5 ECC03C1_5A 480. ECC03C2_5A 565. ECC03C4_5A 730. ECC03C6_5A 1,780. ECC03C8_5A 565.
6 ECC03C1_6A 535. ECC03C2_6A 620. ECC03C4_6A 785. ECC03C6_6A 1,830. ECC03C8_6A 620.
7 ECC03C1_7A 600. ECC03C2_7A 685. ECC03C4_7A 850. ECC03C6_7A 1,890. ECC03C8_7A 685.
8 ECC03C1_8A 655. ECC03C2_8A 740. ECC03C4_8A 905. ECC03C6_8A 1,940. ECC03C8_8A 740.
9 ECC03C1_9A 720. ECC03C2_9A 805. ECC03C4_9A 970. ECC03C6_9A 2,000. ECC03C8_9A 805.
10 ECC03C1_AA 785. ECC03C2_AA 870. ECC03C4_AA 1,035. ECC03C6_AA 2,050. ECC03C8_AA 870.
12 ECC03C1_BA 845. ECC03C2_BA 930. ECC03C4_BA 1,095. ECC03C6_BA 2,150. ECC03C8_BA 930.
Sufx Coil Voltage Sufx Coil Voltage Sufx Coil Voltage
A
B
C
120/60 or 110/50
240/60 or 220/50
480/60 or 440/50
D
E
H
600/60 or 550/50
208/60
277/60 or 240/50
T
V
X
24/60
28/60 or 24/50
347/60
Enclosed Electrically Held
Lighting Contactor
Number of
Poles
NEMA 1 NEMA 3R NEMA 4X NEMA 7/9 NEMA 12
Catalog
Number

Price
U.S. $
Catalog
Number

Price
U.S. $
Catalog
Number

Price
U.S. $
Catalog
Number

Price
U.S. $
Catalog
Number

Price
U.S. $
Continuous Amps 30
2 ECC04C1_2A 445. ECC04C2_2A 530. ECC04C4_2A 695. ECC04C6_2A 1,750. ECC04C8_2A 530.
3 ECC04C1_3A 500. ECC04C2_3A 585. ECC04C4_3A 750. ECC04C6_3A 1,810. ECC04C8_3A 585.
4 ECC04C1_4A 555. ECC04C2_4A 640. ECC04C4_4A 805. ECC04C6_4A 1,860. ECC04C8_4A 640.
5 ECC04C1_5A 680. ECC04C2_5A 765. ECC04C4_5A 930. ECC04C6_5A 1,920. ECC04C8_5A 765.
6 ECC04C1_6A 745. ECC04C2_6A 830. ECC04C4_6A 995. ECC04C6_6A 1,970. ECC04C8_6A 830.
7 ECC04C1_7A 820. ECC04C2_7A 905. ECC04C4_7A 1,070. ECC04C6_7A 2,030. ECC04C8_7A 905.
8 ECC04C1_8A 895. ECC04C2_8A 980. ECC04C4_8A 1,145. ECC04C6_8A 2,140. ECC04C8_8A 980.
9 ECC04C1_9A 970. ECC04C2_9A 1,055. ECC04C4_9A 1,220. ECC04C6_9A 2,200. ECC04C8_9A 1,055.
10 ECC04C1_AA 1,025. ECC04C2_AA 1,110. ECC04C4_AA 1,275. ECC04C6_AA 2,250. ECC04C8_AA 1,110.
12 ECC04C1_BA 1,125. ECC04C2_BA 1,210. ECC04C4_BA 1,375. ECC04C6_BA 2,360. ECC04C8_BA 1,210.
Sufx Coil Voltage Sufx Coil Voltage Sufx Coil Voltage
A
B
C
120/60 or 110/50
240/60 or 220/50
480/60 or 440/50
D
E
H
600/60 or 550/50
208/60
277/60 or 240/50
T
V
X
24/60
28/60 or 24/50
347/60
Enclosed Mechanically Held
Lighting Contactor
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD-1C
January 2004
CA03701001E For more information visit: www.eatonelectrical.com
17
Lighting Contactors
Enclosed Control
C30CN Enclosed Modication Codes
Modication Codes
Eaton Electrical offers a wide range of Cutler-Hammer
Enclosed Control to service your lighting contactor needs.
The base catalog numbering scheme allows you to select
such things as type of lighting contactor, coil voltage, NEMA
enclosure rating and number of poles (for more details see
Page 15 on what each position means).
When more options or accessories are needed, modication
code sufxes can be added to the 10-digit Catalog Number.
Include a hyphen (-) after the 10-digit basic Catalog Number
and then add as many modication codes as required to
meet your applications needs. For ease of processing, it is
recommended that all modication codes be entered alpha-
betically to make it easier to nd them.
Example: To order an ECC03C1B8A with 2NO extra side
mounted auxiliary contacts and a 100 extra VA control
power transformer, the Catalog Number is: ECC03C1B8A-
A30C3.
It is possible to create a Catalog Number or combination
of products and modication codes that is not possible to
build, but we will make every effort to meet your needs
and will notify you of alternatives if necessary.
Table 28. A Auxiliary Contacts
Table 29. B Breaker Modications
Table 30. C Control Power Transformers, Control Wiring
Modication Catalog
Number
Sufx
Description Adder
U.S. $
Top Mounted
Auxiliary
Contacts
A13 1NO 81.
A14 1NC 81.
A15 1NO-1NC 161.
A16 2NO 161.
A17 2NC 161.
A23 2NO-2NC 317.
Auxiliary
Contacts on
Operating
Mechanism
of Disconnect
A42 Contacts mounted on operating mech-
anism of disconnect switch, 1NO-1NC
109.
A43 Contacts mounted on operating mech-
anism of disconnect switch, 2NO-2NC
161.
Modication Catalog
Number
Sufx
Description Adder
U.S. $
Breaker B3 Shunt Trip on Circuit Breaker
48 127V AC or DC
289.
B4 Shunt Trip on Circuit Breaker
9 24V AC or DC
289.
B5 Shunt Trip on Circuit Breaker
208 380V AC
289.
B6 Shunt Trip on Circuit Breaker
415 600V AC or 220 250V DC
289.
Modication Catalog
Number
Sufx
Description Adder
U.S. $
Control Power
Transformers
Make sure
8th character
species
primary/
secondary
voltage.
See Page 15.
C1 Standard Size Control Transformer,
120V/60 Hz, 110V/50 Hz Secondary
with 2 Primary and 1 Secondary
Fuse
196.
C2 Standard Size Control Transformer,
24V/60 Hz Secondary with 2 Primary
and 1 Secondary Fuse
196.
C3 100 VA Extra Capacity CPT, 120V/
60 Hz, 110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
334.
C4 100 VA Extra Capacity CPT, 24V/
60 Hz Secondary with 2 Primary and
1 Secondary Fuse
346.
C5 200 VA Extra Capacity CPT, 120V/
60 Hz, 110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
467.
C6 200 VA Extra Capacity CPT, 24V/
60 Hz Secondary with 2 Primary and
1 Secondary Fuse
467.
C7 300 VA Extra Capacity CPT, 120V/
60 Hz, 110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
606.
C8 400 VA Extra Capacity CPT, 120V/
60 Hz, 110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
884.
C9 1 kVA Extra Capacity CPT, 120V/
60 Hz, 110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
1,201.
C10 2 kVA Extra Capacity CPT, 120V/
60 Hz, 110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
1,796.
C11 Control Transformer Order by
Description (Price on Application)
Consult
Factory
3-Wire
Control
C18 3-Wire Control Module for
Mechanically-Held Lighting
Contactor (C30CN)
20.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD-1C
January 2004
18
For more information visit: www.eatonelectrical.com CA03701001E
Lighting Contactors
Enclosed Control
C30CN Enclosed Modication Codes
Table 31. E Enclosure Modications, Duplex Outlet
Table 32. F Fuse Blocks
Table 33. G Ground Fault Protection, Ground Fault Relay
Table 34. L Lightning Arrestors, Label, Lighting Poles

To order normally closed power poles add the L Modication code. The
total number of poles will not change but the specied number from
this table will be congured for normally closed.
Table 35. N Nameplates
Table 36. P Pilot Lights, Pushbuttons, Program Timers, Percentage Timers

Not available in NEMA 1 enclosure.


Modication Catalog
Number
Sufx
Description Adder
U.S. $
Enclosure
Modications
E3 Oversize Enclosure Consult
Factory
Duplex Outlet E12 Convenience Duplex Outlet
Mounted on Side of Enclosure
Consult
Factory
Modication Catalog
Number
Sufx
Description Adder
U.S. $
Fuse Blocks F5 30 Ampere Control Circuit
Fuseholder (KTK) Mounted on
Panel (Unwired), Fuse Not Supplied
199.
F6 30 Ampere Control Circuit
Fuseholder Mounted on Panel
(Unwired), 5A KTK Fuse Supplied
199.
Modication Catalog
Number
Sufx
Description Adder
U.S. $
Ground Fault
Protection
G1 Install Ground Fault Protection 2,691.
Ground Fault
Relay
G3 Ground Fault Relay Installed,
Unwired
1,201.
Modication Catalog
Number
Sufx
Description Adder
U.S. $
Lightning
Arrestors
L3 Installed on Panel 279.
Carton
Label
L10 Customer Marking Specify 20.
Normally
Closed
Poles

L21 1 Normally Closed Power Pole 20.


L22 2 Normally Closed Power Poles 20.
L23 3 Normally Closed Power Poles 20.
L24 4 Normally Closed Power Poles 20.
L25 5 Normally Closed Power Poles 20.
L26 6 Normally Closed Power Poles 20.
L27 7 Normally Closed Power Poles 20.
L28 8 Normally Closed Power Poles 20.
Modication Catalog
Number
Sufx
Description
Nameplate N1 Identication Nameplate on Enclosure
Modication Catalog
Number Sufx
Description Adder
U.S. $
Push-to-Test Pilot Lights

P1 Push-to-Test Pilot Light (Red RUN) Wired to Coil 217.


P2 Push-to-Test Pilot Light (Green OFF) Wired in Series with Auxiliary Contact 302.
P3 Combination of P1 and P2 Above 517.
P4 Push-to-Test Pilot Light (Amber RUN) Wired to Coil 217.
Pushbuttons P5

EMERGENCY STOP Mushroom Head 289.


P7 START/STOP 171.
P8 ON/OFF 171.
P9 START 171.
P10 ON 171.
P11 OFF 171.
P18 Pushbutton with Legend Plate (Order by Description) Consult Factory
Pilot Lights P19 With 1 Amber Pilot Light Marked POWER AVAILABLE Wired to Load Side of 2
Fuses of Circuit Breaker
217.
P20 Pilot Light (Amber) RUN Wired to Coil 171.
P21 With 1 Red Pilot Light Marked RUN Wired through NO Auxiliary Contact 171.
P22 With 1 Push-to-Test Red Light Marked RUN Wired through NO Auxiliary Contact 171.
P23 Pilot Light Red RUN 171.
P24 Pilot Light Red ON 171.
P25 Pilot Light Green OFF 171.
P26 Pilot Light (Order by Description) Consult Factory
Illuminated Pushbutton P27 Illuminated Pushbutton (Order by Description) Consult Factory
Program Timers P43 15-Minute Program Timer 730.
P44 24-Hour Program Timer 730.
P45 7-Day Program Timer with Day Omission Feature 911.
Percentage Timers P47 15-Minute Percentage Timer 730.
P48 60-Minute Percentage Timer 730.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD-1C