Single Phase Relay

testing unit
PTE-100-C
Plus
PTE-100-C Plus
CHARACTERISTICS
Selectable power outputs:
Variable AC current output up to 0-250 A.
Variable AC voltage output up to 0-250 V.
Variable DC voltage output up to 0-350 V.
Variable auxiliary voltage supply 0-250 V DC.
Variable AC voltage 0-140 V.
Variable Frequency 40-70 Hz.
Variable Phase Angle 0-359.9.
Isolated and electronically protected outputs.
1-ms resolution chronometer.
External and internal signal measurement: voltmeter, ammeter,
frequency meter, power meter, impedance meter and phase meter.
Elapsed injection time limit control.
Maximum current output limit control.
Output current preset function.
RS-232 communications port.
EuroSMCs exclusive PTE-BUS.
Dimensions: 200 x 300 x 200 mm / 15.5kg.
8 x 12 x 8 in / 35 lb.
APPLICATIONS
Single-phase testing of relays:
Definite and inverse time overcurrent.
Min/max. AC / DC voltage.
Directional overcurrent
Frequency
Distance
Synchronizing
Directional power
Loss of Field
Reverse Phase
Negative sequence overcurrent
Reverse phase / voltage
Thermal
Power factor
Overvoltage
Earth detection
Phase angle, Out of Step
A.C. / D.C. reclosing
Directional voltage
Directional voltage and power
Moulded Case Breakers (MCB, MCCB) testing.
CT Knee-point analysis and many other accurate electrical
measurements.
Three-phase testing when combined with other PTE-range
equipment.
The PTE-100-C Plus can test all
types of single phase relays from
electromechanical to digital relays.
DESCRIPTION
The PTE-100-C Plus is a portable injector specially designed
to test the protective functions of electromechanical, analogue
and digital relays. It features a variac-type variable AC current
output up to 250 A, AC voltage up to 250 V, or DC voltage
up to 350 V. There is also an electronic variable AC voltage
output up to 0-140 V, 40- 70 Hz frequency, and a phase
shifter to 0-359.9.
Another independent, stabilized and electronically protected
DC output can also supply 0 to 250 V for your auxiliary
voltage requirements.
A rich set of built-in measurement functions for internal and
external signals (e.g. AC/DC current, voltage, frequency,
phase angle, impedance and apparent power) and useful
operating controls like time and current limitation make the
PTE-100-C Plus the most powerful, small and easy to use unit
in its market.
You can preset the injection value before you actually apply it
to the connected relay. Also, the unit stores and displays the
maximum injected value in 10 milliseconds, thus allowing the
testing of very fast instantaneous overcurrent elements. Thanks
to the injection lapse time limit function, you can easily verify
the safety threshold of some reclosers.
The PTE-100-C Plus can be connected to your PC through its
standard RS-232 port for calibration (no need to open the
unit), data download and software-automated operation.
Another connector, the PTE-BUS, can be used to integrate
the PTE-100-C Plus with any other component of the PTE
family, dramatically expanding the testing capabilities. You
can, for example, use the PTE-100-C Plus built-in timer
to control the operation of a PTE-100-V or a PTE-300-V or
can synchronize these units signal generators to the
PTE-100-C Plus reference.
OPERATION
The PTE-100-C Plus is engineered
with ease of operation in mind.
You wire the relay, reset the
timer, regulate the variac and
wait for the relay to trip. The
output will stop automatically
and the time and pickup values
will be shown on the corresponding
displays.
You have all what you need: direct visual
control, timing, measurement, and power up
to 1,000VA for the toughest burdens. To better
adapt the output power to the loads characteristics,
we have added an autotransformer with four current
and two voltage taps between the PTE-100-C Plus
and your relay. In this way, you can choose the
optimum current/voltage combination to deliver the
available 1000 VA with the required accuracy. To
better trace those characteristic curves, you can also have
the ammeter display per cent of a given current value, rather
than absolute amperes.
If you have three-phase PTE equipment, combine it with the
PTE-100-C Plus for the higher power-demanding applications,
like some three-phase directional overcurrent relays.
A number of primary applications can also be achieved. For
example, you can test multiple MCBs or measure a current
transformers saturation, or knee point.
MEASUREMENT FUNCTIONS
The following external or internal magnitudes can be measured
with the PTE-100-PLUS:
External AC current up to 10 A between the common power
output tap and the active AC output tap.
Voltmeter: up to 300 V AC or 400 V DC (up to 1000 V
with the PTE-FCH).
Frequency: 20-2000 Hz.
Phase angle between:
- The output current and the voltage drop at the output tap
(the loads impedance angle).
- The output current and the independent voltage output.
- The output current and an external voltage.
- External current and voltage signals.
Impedance ():
- Present at the current output.
- Measured with the 4-wire method.
Apparent Power (VA):
- Across the current circuit.
- As the product of the applied current and voltage
magnitudes.
PTE-100-C Plus is designed for easy
and intuitive operation.
1
7
9
10
11
12
13
14
15
16
17
2
4
PTE-100-C
Plus
5
6
3
8
VARIABLE OUTPUT CHANNEL
Independent, protected 0 -140 V AC, frequency
at 40-70 Hz and 0-359.9 referred to the output
current.
REFERENCE SYCHRONIZING SELECTOR
Choose between the mains supply or the internal
variable frequency generator as the synchronization
reference.
AMPLITUDE, FREQUENCY AND PHASE
ANGLE SELECTOR
The regulated value is shown on the digital display
of the instrument.
CONDITION ALARMS
Thermal and overload protection. Automatic output
cut-off and reset.
ADJUSTMENT DIGIT SELECTION
Two different modes can be selected, coarse or
fine.
PARAMETER REGULATION
Voltage, frequency and phase angle regulation
rotary knob.
SIGNAL MONITOR
Timer stop condition is sensed on these inputs, by
normally open/closed dry contact or voltage rise/
drop in live contact. A 20-ms positive or negative
square pulse mode is also selectable as a timer stop
signal. External magnitudes between 5 and 250 V
can also be measured in the live contact input.
SPECIAL MODE AND MEASUREMENT
FUNCTIONS
- AC / DC voltage measurement.
- Frequency measurement.
- Output voltage measurement.
- Phase angle measurement.
- Impedance measurement.
- Apparent Power (VA) measurement.
- Percent-mode output current display.
- Maximum injected current reading.
- Max. injection duration.
- Max. current limit.
- Instantaneous current preset.
RS-232 COM PORT
Provides bidirectional asynchronous
communications:
For software-assisted Closed Case Calibration,
test automation and data acquisition.
For direct test results printout to a serial printer.
PTE-BUS
For signalling and electrical synchronization to other
PTE-range equipment.
CURRENT OUTPUTS
Variac-based current regulation within 4 ranges
available at the output transformers taps.
TIMER
1-ms accuracy to measure the relays tripping time.
Digital LED display and 6 different start/stop event
combinations on dry or live contacts.
POWER INPUT
You can order your PTE-100-C Plus for 110 or 220
V mains supply. A standard SCHUKO-type power
cord is supplied unless otherwise specified. The
incoming power is filtered from line perturbances
and protected by a an external fuse.
AUXILIARY DC VOLTAGE
Independent, stabilized and short-circuitable DC
supply for auxiliary 0-250 V voltage at 0.25 A.
OUTPUT PROTECTION
Electronic thermal, short-circuit and overload
protection is provided for all the power outputs.
The protected condition is indicated by an alarm
LED and the blocked output resumes automatically
when the condition is cleared.
AC VOLTAGE OUTPUT
Variac-regulated 250 V AC output at 4 A, not
simultaneous with the current or DC voltage taps.
DC VOLTAGE OUTPUT
Variac-regulated 350 V DC output at 2.8 A, not
simultaneous with the current or AC voltage taps.
1
2
3
4
5
6
7
8
9
12
13
15
16
17
14
11
10
s
o
f
t
w
a
r
e
SOME APPLICATION EXAMPLES
Test of overcurrent relays
Select the current value, by injecting in the relay.
Output OFF, RESET, output ON.
Relay trips. Write down time and current.
Test of frequency relays
Set the voltage and frequency values using special
measurement functions.
Output OFF, output ON.
The relay trips. Write down time and current.
Test of directional relays
Set values for voltage, current and phase angle.
Output OFF (both current and voltage), RESET, voltage output ON,
current output ON.
The relay trips. Write down the values of time, current, voltage, and
phase angle.
Test of synchronizing relays
Set values for both voltages.
Set the phase angle between the two voltages.
Output OFF (in both voltages).
Output ON in the lid, output ON in the main body of the unit.
The relay trips. Write down the values of phase angle and time.
I
V
I
V
V1
V2
s
o
f
t
w
a
r
e
STANDARD ACCESORIES
1 voltage supply cable 1.5 m length.
2 connection cables 2 meters length
and 16 mm
2
section for high currents.
8 crocodile clips, input 4 mm.
8 connection cables 2 meters length and 2.5 mm
2

section.
2 adaptor plugs 6 mm to 4 mm.
1 RS-232 Cable.
Spare fuses.
Instruction manual.
1 nylon protection bag.
Calibration software,
FAA-CAL.
Description: The software FAA-CAL enables to calibrate
and adjust the PTE-100-C PLUS without any addtional
accesory nor opening the equipment. The program is
completely automatic and requires a reference standard.
The software indicates the connection diagram required
for calibrating each parameter and creates a printed
calibration report.
Description: The PTE-OCT Software is designed to
preform Overcurrent Relay Tests: Inverse Time Overcurrent
Relays and Definite Time Overcurrent Relays.
The test is directed by the software, including the current
values required. All the test results and data are stored in
MS Access format A graphic curve editor enables to easily
create standard curves.
PTE-TDC SOFTWARE
TEST DATA CAPTURE SOFTWARE
This software is intended to acquire data from a PTE-
100-C equipment, making easy the task of acquiring an
adequate data format in order to print or transfer results
into a file. The file can be Microsoft Access or a standard
ASCII format. It is possible to store test results and retrieve
to print.
The software is developed in Windows and it is easy to
use. It enables identification of results, by means of a test
header where data can be introduced, such as dates,
locations codes, operator, device under test, etc.
The connection between the PC and the PTE-100-C Plus is
made by a cable supplied with the equipment.
PTE-OCT SOFTWARE
OVERCURRENT RELAYS TEST SOFTWARE
FAA-CAL SOFTWARE
CALIBRATION AND ADJUSTMENT SOFTWARE
POWER OUTPUTS
OUTPUTS NO LOAD FULL LOAD MAXIMUM DUTY
VOLTAGE VOLTAGE CURRENT CYCLE
0-5 A 200V 163V 5.5A 1 min. ON / 15 min OFF
0-25A 40V 33V 27.5A 1 min. ON / 15 min OFF
0-50A 20V 16V 55A 1 min. ON / 15 min OFF
0-100A 10V 7.6V 110A 1 min. ON / 15 min OFF
0-150A 10V 6.6V 150A 10 seg. ON / 5 min. OFF
0-210A 10V 4.2V 210A 5 seg. ON / 5 min. OFF
0-250A 10V 4.2V 250A 3 seg. ON / 5 min. OFF
0-250V AC 285V 220V 4A 10 min. ON/ 15 min. OFF
0-350V DC 292V 270V 2.8A 5 min. ON/ 15 min. OFF
VOLTAGE, FREQUENCY, PHASE ANGLE OUTPUTS
VOLTAGE RANGE: 0 - 140Vac
POWER: 30VA (70 140 Vac)
I MAX.: 0.45 A (0 - 70Vac)
RESOLUTION: Coarse: 10V / Fine: 0.1V
LOAD REGULATION: <1% (@ 0 Full Load , cos = 1)
LINE REGULATION: <0.5%
DISTORTION: <0.5% @ 50Hz
SWITCHING NOISE: <0.2% Fs (0.75Vpp) @ 0-140Vac
FREQUENCY OUTPUT: Range: 40 - 70Hz
Resolution: Coarse: 1Hz / Fine: 0.1Hz
SYNCHRONISM SOURCE: Selectable references
Line / Internal Freq Generator
PHASE ANGLE: Line Reference only
Range: 0 - 359.9
Resolution: Coarse: 10 / Fine: 0.1
TECHNICAL SPECIFICATION
P
l
e
a
s
e

N
o
t
e
:

D
u
e

t
o

t
h
e

c
o
n
t
i
n
u
o
u
s

r
e
s
e
a
r
c
h

a
n
d

d
e
v
e
l
o
p
m
e
n
t

b
y

E
U
R
O
S
M
C
,

s
p
e
c
i
f
i
c
a
t
i
o
n
s

i
n

t
h
i
s

c
a
t
a
l
o
g

m
a
y

b
e

c
h
a
n
g
e
d

w
i
t
h
o
u
t

p
r
e
v
i
o
u
s

n
o
t
i
c
e
.
SPECIFIC SELECTION FUNCTIONS
In PERCENTAGE TIME LIMIT CURRENT PRESET
(A) (s.) LIMIT (A) CURRENT (A)
MIN. 00.1 0.01 0.1 0.1
MAX. 99.99 99.99 100.0 100.0
RESOLUTION 0.01 0.01 0.1 0.1
AUXILIARY OUTPUTS
AUXILIARY DC MAXIMUM
VOLTAGE SUPPLY (OUT 3) VOLTAGE CURRENT
0 - 50V DC 0 - 50V 1A
0 - 125V DC 50 - 125V 0.5A
0 - 250V DC 125 - 250V 0.25A
SIGNAL MONITOR
Dry Contact Input
Open circuit voltage: 10.2 V. D.C.
Short-circuit current: 25 mA.
Fuse protected.
Voltage Input
Level Limits: from 5 to 250 V A.C./D.C.
Input Impedance: 19 k
Fuse protected.
GENERAL
Temperature Range: Operation: 0 - 50 C / Storing: -20 - 70 C
Voltage supply: 230 V 10% 50-60 Hz
115 V 10% 60 Hz.
Dimensions:
Height:
200 mm
Width:
300 mm
Depth:
200 mm
8 12 8
Weight: 15.5 Kg. - 35 lb.
BUILT-IN TIMER
MEASURING RANGES: Time: 0.001 to 99999 s. (autorange).
Cycles: 000.1 to 9999.9 Cycles (referenced frequency).
ACCURACY: 0.003% of the reading 1 dig.
TIME START: By activation/deactivation of the power output.
TIMER STOP: Selectable between activation or deactivation of the Signal Monitor.
EUROSMC, S.A.
Polgono Industrial P-29, Calle Buril, 69. 28400 Collado-Villalba. Madrid
(Spain). Tels: 34 - 91 - 849 89 80*. Fax: 34 - 91 - 851 25 53
www.eurosmc.com e-mail: sales@eurosmc.com
DISTRIBUTED BY:
MEASUREMENT FUNCTIONS
MEASURE CURRENT VOLTAGE VOLTAGE FREQ. VOLT. TAP PHASE ANGLE POWER IMPEDAN.
FUNCTION (AC) (AC) (DC) (Hz) (AC) (degrees) (VA) (Z)
MIN 0.0070 000.1 000.1 20.000 0.01 000.0 00.01 0.001
MAX 299.9 300.0* 400.0* 2000.0 199.9 359.9 999.9 999.9
ACCURACY 1% R 1% R 1% R 0.003 Hz 1% R 2 2% R 2% R
(10% to
full range)
1 dig. 1 dig. 1 dig. 1 dig. 1 dig. 1 dig. 1 dig. 1 dig.
RESOLUTION 0.001 0.1 0.1 0.01 0.01 0.1 0.01 0.001
* Up to 1,000V with the PTE-FCH option