You are on page 1of 6

GENERAL DATA

PROCESS
CONDITIONS

METER

TRANSMITTER

ACCESSORIES

PURCHASE

Notes:

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

Tag Number
Service
PID No.

43
44
45
46
47
48
49
50
51
52
53
54
55

Integral Flow Indicator


Accuracy
Accuracy

Case

002200-FIT -824
CONDENSATE FISCAL METER

Nace Applicable

Line Number
Line Size
Piping Class
Line Material
Line Schedule
Fluid
Special Conditions
Phase
State
Insulation Code
Flow
Min. Norm.
Max.
Press.
Min. Norm.
Max.
Temp.
Min. Norm.
Max.
Density
Min. Norm.
Max.
Design Press
Min.
Max.
Design Temp
Min.
Max.
Viscosity
Min. Norm.
Max.
Molecular Weight
Cp/Cv
Compressibility - Factor Z
Vapour Pressure @ Nominal Temp.
Max Allowable Press. Loss
Meter Type
Size
Rating
Instrum. Range
Min.
Calibrat. Range
Min.
System Range
Min.
Electrical Connection
Pressure Loss @ Max. Flow
Distance to Transmitter
Flanges Material
Tube Material
Meter Enclosure Material
Enclosure Pressure Relief Device
Mounting
Housing Material
Electrical Connection
Output Signal
Area Classification
Elec. Protection Class
Surge Protection Device

Mounting Kit
Sensor Gland

Manufacturer
Client Reference
Material Code

Max.
Max.
Max.

Units
Units
Units
Units
Units
Units
Units

Face
Units
Units
Units

Power Supply
Other Output Signal
Req. Safety Certification
Enclosure Protection

Cable Gland

Weight
Model No.
Requisition No.

See notes

CONDENSATE FISCAL DATA SHEET


Coriolis Flow Meter
00

DNW

RAN

NRC/ATI

11-July-2014

Issued For Review

Sheet 1 of 2

No.

By

Chk

Appr

Date

Revision

Code:

Doc. No.:

220802

GENERAL DATA

PROCESS
CONDITIONS

METER

TRANSMITTER

ACCESSORIES

PURCHASE

Notes:

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

Tag Number
Service
PID No.

43
44
45
46
47
48
49
50
51
52
53
54
55

Integral Flow Indicator


Accuracy
Accuracy

Size
Line Material
Size
Line Material
Fluid
Phase
Insulation Code
Required Total Capacity
Molecular Weight
Viscoity @ Op. Cond.
Cp/Cv
Max Operating Press.
Max Operating Temp.
Back Press.
Build up Back Pressure
Max Allowable Press. Loss

Case

002200-FIT -824
CONDENSATE FISCAL METER

Nace Applicable
Line Number
Piping Class
Line Schedule
Special Conditions
State
Min.
Min.
Min.
Min.
Min.
Min.
Min.

Norm.
Norm.
Norm.
Norm.

Norm.
Cp/Cv

Meter Type
Size
Rating
Instrum. Range
Min.
Calibrat. Range
Min.
System Range
Min.
Electrical Connection
Pressure Loss @ Max. Flow
Distance to Transmitter
Flanges Material
Tube Material
Meter Enclosure Material
Enclosure Pressure Relief Device
Mounting
Housing Material
Electrical Connection
Output Signal
Area Classification
Elec. Protection Class
Surge Protection Device

Mounting Kit
Sensor Gland

Manufacturer
Client Reference
Material Code

Max.
Max.
Max.
Max.
Max.
Max.
Max.

Units
Units
Units
Units
Units
Units
Units

Max.
Max.
Max.

Face
Units
Units
Units

Power Supply
Other Output Signal
Req. Safety Certification
Enclosure Protection

Cable Gland

Weight
Model No.
Requisition No.

See notes

CONDENSATE FISCAL DATA SHEET


Safety Valve
00

DNW

RAN

NRC/ATI

11-July-2014

Issued For Review

Sheet 1 of 2

No.

By

Chk

Appr

Date

Revision

Code:

Doc. No.:

220802

Tag number:

002200-FIT -824

You might also like