You are on page 1of 86

Analogue Instruments

ENERGY DIVISION
1
Features
Extensive range
A ccurate m easurem ent and display of
electrical and electronic param eters
W ide range of case styles and
specifications
M axim um reliability in harsh
environm ents
Benefits
Low cost
Local indication
Ease of installation
M inim al training
Low m aintenance
R easonable accuracy
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
B uilding m anagem ent
U tility pow er m onitoring
Process control
M otor control
Approvals
U L, C SA , A B S, LR S, B V, ISSeP
Contents Page
DIN Panel Meters 2 29
A n extensive range of 48, 72, 96 and 144m m D IN style panel
m eters. Short-scale am m eters, voltm eters and frequency m eters
incorporate slide-in dials and term inal covers. Long-scale m eters
are also available. M eters for pow er or energy contain in-built
transducers and can be custom ised to suit m any different system
configurations and ranges.
Instrument Selector Switches 30 31
Panel m ounted selector sw itches offering a 7-position
voltm eter sw itch and a 4-position am m eter sw itch for reading
line-to-line or line-to-neutral voltage and phase current.
070 Series ANSI Switchboard Meters 32 62
A n extensive range of analogue and digital/analogue m eters in
4
1
2" and 8
3
4" A N SI case styles. M eters utilise a high shock oil
dam pened m ovem ent, and provide 1% accuracy for all R M S A C
and D C ranges. The range offers various custom ised options and
features. U L, C SA , A B S and ISSeP approvals.
549 Series Panel Meters 63 65
C om pact panel m eters designed to fit standard 1
7
32" sw itch
knock-outs. The range offers high accuracy A C and D C am m eters
and voltm eters, elapsed tim e m eters and im pulse counters.
A B S approvals.
Saxon Series Panel Indicators 66 67
A range of 2
1
2", 3
1
2" and 4
1
2" surface m ount panel m eters utilising
taut band m echanism s and offering IP54 protection. The range
offers iron vane and m oving coil A C and D C am m eters and
voltm eters, elapsed tim e and frequency m eters. U L approvals.
016 Series Fiesta Panel Indicators 68 70
A robust range of short-scale and long-scale 3
1
2" surface m ount
panel m eters offering IP55 protection and featuring w ide
view -contoured w indow s. The range offers iron vane and
m oving coil A C and D C am m eters and voltm eters, elapsed
tim e and frequency m eters. U L approvals.
Challenger Series 71 75
C hallenger analogue panel m eters feature a detachable low er
fascia plate, w hich allow s either surface or w indow m ounting.
M eters use a high torque pivot and jew el m ovem ent.
078/080/087 Series Sealed and Ruggedised Indicators 76 80
D esigned to com ply w ith industrial, m arine and m ilitary
specifications, these 240 and 90 scale m eters m eters
are resistant to extrem e shock, vibration, tem perature, dirt
and hum idity. The range offers a w ide range of bezel sizes fitted
w ith toughened glass.
Guide to Catalogue Numbering Systems and Glossary 81 82
Analogue Instruments
H igh quality analogue instrum ents designed to m easure an extensive
range of electrical and electronic param eters. This com prehensive range
offers D IN instrum ents, A N SI sw itchboard m eters, panel indicators,
sealed and ruggedised instrum ents, and com plem entary selector
sw itches for line-to-line and line-to-neutral readings. Instrum ents are
precision engineered and robust in design, ensuring accurate
m easurem ent and display in the m ost dem anding of environm ents.
A llinstrum ents are available in a range of styles, sizes and specifications
to m eet the exacting needs of your industry.
2
Features
A range of the m ost popular short-scale
m easuring instrum ents in 4 case sizes
Shock resistant sprung pivot and jew el
m ovem ent
Term inal covers supplied as standard
EM C hard frequency m eter are fully
EM C and LVD com pliant
1
/4" fast onterm inals available
Benefits
Low cost
Local indication
Ease of installation
M inim al training
Low m aintenance
C ustom ised options and features
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
B uilding m anagem ent
U tility pow er m onitoring
Process control
M otor control
Approvals
Lloyds:
03/00055 - M oving coil m eters
03/00056 - M oving iron m eters
03/00057 - Frequency m eters
DIN Panel Meters Short scale
A range of 48, 72, 96 and 144m m D IN style panel m eters m easuring
all electrical param eters and featuring m oving coil or m oving iron
m ovem ents. A ll m eters incorporate slide-in dials and term inal covers as
standard. A range of custom ised options is available.
Movements
Moving Coil Meter
C entre cored, self shielding m oving coil m ovem ent, using pivots, hairsprings and sprung
jew els. Seven variations have been designed in m ovem ent ranges: all interm ediate
ranges are achieved by shunting the next low est range. A ll D C voltm eters are 1000
ohm s per volt, rectified product run at 900 ohm s per volt, m illivolt m eters use the 5
m illiam p m ovem ent.
Moving Iron Meter
C lapper type repulsion design using pivots, hairsprings and jew el m ovem ents.
The bottom jew el is oil filled to provide dam ping w hile the top is sprung for resilience.
A ll voltm eters are m anufactured w ith external voltage dropper resistors to substantially
reduce the self heating effects.
Frequency Meter
M eter uses a 100 m icroam p 4000 ohm m ovem ent driven by an EM C hard frequency
conversion circuit.
Dials, Scales and Pointers
Standard dials are w hite m atte w ith black printed scales and bar knife-edge pointers.
B lack dials w ith w hite or yellow scales and pointers are also available. Interchangeable
slide-in dials are used on the E242, E243, E244 and 246 90 m oving iron, m oving coil
and frequency m eter m odels.
G eneral options include red supplem entary pointers, red indexes (quadrant scales), red,
green or blue lines, bands or segm ents, finely spaced divisions, m ulti-scales, special
scales and captions to custom er' requirem ents.
Specifications
Type of M oving iron for M oving coil for M oving coil w ith M oving coil w ith M axim um C om bined M D I
instrument current and current and rectifiers for built-in transducer dem and w ith m oving
voltage voltage current and for frequency indicators iron m ovem ent
voltage m easurem ent
Format 48 x 48m m 48 x 48m m 48 x 48m m
72 x 72m m 72 x 72m m 72 x 72m m 72 x 72m m 72 x 72m m
96 x 96m m 96 x 96m m 96 x 96m m 96 x 96m m 96 x 96m m 96 x 96m m
144 x 144m m 144 x 144m m 144 x 144m m 144 x 144m m
Movement Sprung pivot Sprung pivot Sprung pivot Sprung pivot Sprung pivot Sprung pivot
type jew el w ith silicon jew el w ith eddy jew el w ith eddy jew el w ith eddy jew el w ith silicon jew el w ith silicon
oil dam ping current dam ping current dam ping current dam ping oil dam ping oil dam ping
Burden 0.5VA - 15A See detailed See detailed See detailed 2.5VA 3VA
then 0.8VA specifications specifications specifications
voltm eters 4.5VA
Accuracy 1.5% to 1.5% to 2.5% to 0.5% to D IN 43780 3% on M D I 3% on M D I
D IN 43780 D IN 43780 D IN 43780 1.5% am m eter
Input type A C current or D C current or R ectified A C Frequency for all M ean R M S value M ean R M S value
voltage voltage current or voltage ranges and m axim um and m axim um
voltage dem and current dem and current
and instantaneous
current
Measuring 6 - 600V 15m V - 600V 6 - 600V 57.7V @ 45H z 1 - 6A 1 - 6A
range 100m A -100A 25A - 100A 100A - 100m A 500V @ 44H z 8, 15 or 20 8, 15 or 20
m inute delays m inute delays
0 - 5A /6A
instantaneous
Dielectric 3kV A C 3KV A C 3KV A C 3KV A C 3KV A C 3KV A C
voltage
withstandtest
3
General Specifications
Dimensions
Perform ance B SEN 60051
M easuring ranges D IN 43701
A ccuracy overload B SEN 60051
D im ensions D IN 43700
Scale m arking generally to D IN 43802
M agnetic influence B SEN 60051
Safety B SEN 61010-1
Term inals C lam p strap M 4 for up to 25A . C lam p strap M 8 for
over 25A .
1
/4" spade term inals available for m odels E243 and E244
H um idity range U p to 95% R H (non condensing)
Test voltage @ 50H z 3kV R M S for 1 m inute
A m m eter ranges 1.0/1.2/1.3/1.5/2.5/4/5/6/8 and decade m ultiples thereof.
O verload A C current x 1.2 continuous x 10 for 5 seconds
A C voltage and frequency x 1.2 continuous x 2 for 5 seconds
Standard calibration 23C . C alibration at other tem peratures available
on request
O perating tem perature -20C to + 60C
D am ping tim e Less than 3 seconds
Enclosure code IP52 as standard
IP54 on request
C ase and base G rade U L94V0 (Lexan 500R )
C ase D im ensions and panel cutout conform to IEC 473, D IN
43700. C ase m ade from glass filled polycarbonate self-
extinguishing and non drip in accordance w ith U L94 V-O .
B ezel Slim -line D IN 43802, black as standard
B ezel w indow Standard sheet glass, w ith zero adjusters w here
appropriate. N on reflecting glass or polycarbonate
shatterproof w indow s are available.
Installation Installations in sw itchboard panel or m osaic
arrangem ent on equipm ent or m achine w ith a panel
thickness of up to 40m m in a horizontal or vertical plane
Fixing on panel Sw ivel captive fasteners, w hich can be fixed
at either corner.
M ounting position N orm al vertical m ounting or as indicated on the scale
in accordance w ith D IN 16257. A deviation of 15 is perm issible
Insulation group Insulation resistance m ore than 5M @ 500 V
Environm ental M easurem ent category III IEC 1010-1
Pollution degree 2 IEC 1010-1
Electrical rating 600V R M S (920V peak)
A pprovals EM C , LVD and Lloyds
Max. panel thickness =40mm
Moving coil measuring range Moving iron measuring range
6 - 60A C = 67m m 0 - 30A C = 64m m
> 60A C = 78m m > 30A C = 67m m
D A B
48 x 48 45 x 45 4
72 x 72 68 x 68 4
96 x 96 92 x 92 4
144 x 144 135 x 135 4
D 53 C C A B
DIN 16257 symbol meaning for
calibration position
Vertical
Horizontal
Inclined 60
Inclination of dial surface.
R equired orientation m ust alw ays be
stated w hen ordering if other than
vertical m ounting is required.
4
DIN Panel Meters Short scale
Moving Iron AC Ammeters and Voltmeters
D esigned to m easure A C current or voltage, these m eters indicate true
R M S values and are substantially independent of system w aveform .
Scales are calibrated dow n to 20% , and am m eters can have overload
scales of x2, x3, x5 or x6 for m otor start duty. A m m eters can be supplied
for use w ith -/1A or -/5A current transform ers, w hilst voltm eters can be
scaled for use w ith voltage transform ers. H eavy dam ping is available as
an option. M eters can be used to m easure D C at reduced accuracy.
Frequency Meters
Frequency m eters use an integral electronic converter and a m oving coil
indicator. These easy to read m eters are C lass 0.5 accurate.
A ccuracy: C lass 1.5
Frequency: 50 or 60H z, (400H z on request)
B urden at 50H z: A m m eters: 0.5VA
voltm eters: U p to 4.5VA m axim um
R atings: A m m eters: 0.5 - 100A A C direct connected (40A for
E242-75A and E246-07A ).
M axim um system voltage 600V A C
Low load / high m iddle, m axim um 10A
Voltm eters: 6 - 600V
B ezel size m m 48 72 96 144
Scale length m m 42 65 94 145
Product codes
A C am m eter E242-75A E243-02A E244-02A 246-071A
x2 overload am m eter E242-752A E243-022A E244-022A 246-072
x3 overload am m eter E242-753A E243-023A E244-023A 246-073
x5 overload am m eter E242-755A E243-025A E244-025A 246-075
x6 overload am m eter E242-756A E243-026A E244-026A 246-076
A C voltm eter E242-75V E243-02V E244-02V 246-07V
R atings: 100-125V A C
200-250V A C
380-440V A C *
500V A C *
*U se E242-013 and 253-TH Z in place of E242-41S for
voltages over 380V
M odels available for use w ith VTs
Frequency: 0.5% : 45/55H z, 55/65H z, 45/65H z, 360/440H z
B urden: 4VA m axim um
Product Codes
Specifications
B ezel size m m 48 72 96
Scale length m m 42 65 94
Product codes E242-41S E243-41S E244-41S
Product Codes
Specifications
Connections
AC Ammeter
AC Voltmeter
Connections
5
Maximum Demand Indicators
The therm al/tim e characteristics of M D I m eters m onitor the m ost
econom ic use of cable, fusegear and transform ers. The directly heated
bim etal elem ent indicates m ean R M S current over 8, 15, or 20 m inutes,
and a red slave pointer show s the highest value reached. The reset knob
is w ire sealable. Scales are calibrated to m atch the C T prim ary plus 20%
overload. End values are selected from : 1.2, 1.8, 2.4, 3, 3.6, 4.8, 6, 7.2,
9 am ps and their m ultiples of 10 and 100.
Combined AC Ammeter and Maximum Demand Indicator
W here m easurem ent of instantaneous and m axim um dem and currents
are required, these instrum ents com bine both m ovem ents in one case.
The m eter can also replace an existing A C am m eter.
M eets the sam e specifications listed above.
A ccuracy: C lass 3
O ptions: 5A for use w ith separate C T
5/5A saturating C T
1/5A saturating C T
B urden at 50 H z: M D I - 2.5VA , C T - 2VA
O verload w ithstand: Standard: 5 x FL for 5 seconds, 10 x FL for 1 second.
W ith saturating C T: 10 x FL for 3 seconds,
20 x FL for 1 second
Frequency: 50/60H z
A ccuracy: M oving iron am m eter: C lass 1.5
M D I: C lass 3
B urden at 50H z: M I - 0.5VA , M D I - 2.5VA
saturating C T - 2VA
B ezel size m m 72 96
Scale length m m * 65 94
Product codes
8 minute time lag
w ithout lim iting C T for use w ith 5A C T E243-16B E244-16B
15 minute time lag
w ithout lim iting C T for use w ith 5A C T E243-16A E244-16A
20 minute time lag
w ithout lim iting C T for use w ith 5A C T E243-16J E244-16J
* Scaled 0/100/120% of C T prim ary value.
Product Codes
Specifications
B ezel size m m 72 96
Scale length m m * 65 94
Product codes
8 minute time lag
w ithout lim iting C T for use w ith 5A C T 3VA E244-16Q
15 minute time lag
w ithout lim iting C T for use w ith 5A C T 3VA E243-16C E244-16C
20 minute time lag
w ithout lim iting C T for use w ith 5A C T 3VA E244-16H
* Scaled 0/100/120% of C T prim ary value.
Product Codes
Specifications
Connections
Maximum Demand Indicators
6
Connections
DC Voltmeter
DC Ammeter
Connections
AC Ammeter
AC Voltmeter
Moving Coil DC Ammeters and Voltmeters
M oving coil m eters are suitable for all D C system s. The linear scale is
calibrated dow n to zero and the accuracy m aintained dow n to 10% .
H igh currents are m easured w ith separate shunts and suitably scaled
indicators. Suppressed, centre and offset zero m odels are available.
Moving Coil Rectified AC Ammeters and Voltmeters
For high frequency or linear full scale A C m easurem ents, these
instrum ents m easure average values of sinusoidal w aveform s and are
scaled in R M S values. The high quality silicon bridge rectifier gives a
linear scale dow n to near zero, w here som e com pression occurs.
A ccuracy: C lass 1.5
R atings: A m m eters: 100A -25A , (200A for long-scale m odel)
4/20m A suppressed zero
40A for m odel E242, E243 and E244 up to 100A
Voltm eters: 50m V-600V
1/5V suppressed zero
50, 60, 75, 100, 150m V for use w ith shunts
Im pedance: A m m eters: 75m V internal shunt above 60m A
Voltm eters: 1000/V above 1V
B ezel size m m 48 72 96 144
Scale length m m 42 65 94 145
Product codes
A m m eters E242-89A E243-01A E244-01A 246-10A
A m m eters suppressed zero E242-89R E243-01R E244-01R 246-10
Voltm eters E242-89V E243-01V E244-01V 246-10V
Voltm eters suppressed zero E242-89S E243-01S E244-01S 246-10S
A ccuracy: 1.5% ES
R atings: A m m eters: 250A -1A A C
O ver 1A via C Ts
Voltm eters: 15 - 600V A C direct connected.
m odels available for use w ith VTs
Frequency: 50/60H z, (Single frequencies 25H z - 3kH z on request)
Product Codes
B ezel size m m 48 72 96 144
Scale length m m 42 65 94 145
Product codes
A m m eters E242-89B E243-01B E244-01B 246-10B
Voltm eters E242-89W E243-01W E244-01W 246-10W
Product Codes
Specifications
Specifications
7
Process Indicators
M eters are used to check process functions locally or rem otely at
centralised controls. These m oving coil instrum ents offer a w ide variety
of electrical and m echanical readouts and are operated by transducer,
tachogenerator, therm ocouple, resistance bulb or other D C analogue
signals. Suppressed, centre and offset zero m odels are available on request.
A ccuracy: C lass 1.5
R atings: 1, 2, 5, 10, 20m A
4/20m A suppressed zero
B ezel size m m 48 72 96 144
Scale length m m 42 65 94 145
Product codes
A C current E242-89A E243-01A E244-01A 246-10A
A C voltage E242-89V E243-01V E244-01V 246-10V
Speed E242-892 E243-012 E244-012 246-102
Frequency E242-893 E243-013 E244-013 246-103
Phase angle E242-894 E243-014 E244-014 246-104
W atts E242-895 E243-015 E244-015 246-105
VA r E242-896 E243-016 E244-016 246-106
VA E242-897 E243-017 E244-017 246-107
Product Codes
Connections
Specifications
8
Features
Extensive range of specialist m eters in
four case sizes
Shock resistant taut band suspension
Vibration-proof H i-Q dam ping
Slide-in dials for 90current, voltage and
frequency on m odels 242, 243 and 244
Term inal covers supplied as standard
Benefits
Low cost
Local indication
Ease of installation
M inim al training
Low m aintenance
C ustom ised options and features
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
B uilding m anagem ent
U tility pow er m onitoring
Process control
M otor control
Approvals
LR S and B V
DIN Panel Meters Long-Scale
A n extensive range of 48, 72, 96 and 144m m D IN style panel m eters
m easuring all electrical and electronic param eters. M eters are shock
resistant and vibration proof and supplied w ith term inal covers.
A selection of slide-in dials and custom ised options are available.
Movements
In C rom pton Instrum entspatented H i-Q taut band suspension, all the delicate parts of
the traditional instrum ents are elim inated. There are no pivots, no jew el bearings, no
hair-springs and no air dam ping vane. Instead, a tough platinum ribbon suspends the
m oving elem ent betw een front and rear tension springs. Specially contoured pads are
fitted to the ends of the spindle, and the w orking gap at each end is filled w ith a high
quality silicon fluid. The pads, together w ith the fluid reservoir, form a system w hich
acts as a resilient built-in shock absorber. This provides both rotational and longitudinal
dam ping as the m oving elem ent floats on oil w ith no bearing friction and is effectively
cushioned against shock and vibration. 360 synchroscopes and pow er factor m eters
have robust pivot and jew el bearings w ith oil dam ping.
Dials, Scales and Pointers
Standard dials are w hite m atte w ith black printed scales and bar knife-edge pointers.
B lack dials w ith w hite or yellow scales and pointers are also available. Interchangeable
slide-in dials are used on m odel num bers 242, 243 and 244 90 m oving iron, m oving coil
and frequency m eters.
G eneral options include red supplem entary pointers, red indexes (quadrant scales), red,
green or blue lines, bands or segm ents, finely spaced divisions, m ulti-scales, special
scales and captions to custom er' requirem ents.
Illumination
M eters com e w ith a full range of illum ination options. Internal illum ination is available
in the follow ing m odels:
244 and 246 short-scale m oving coil and m oving iron vane.
243,244 and 246 long-scale m oving coil and m oving iron vane.
Through-dial (translucent) illum ination on 244 and 246 m odels. Edge illum ination on 243,
244 and 246 m odels. R eplaceable 6, 12 or 24V lam ps are used on all m odels except 243
long-scale m eters, w here the lam ps are internal.
Perform ance B SEN 60051
M easuring ranges D IN 43701
A ccuracy overload B SEN 60051
D im ensions D IN 43700
Scale m arking generally D IN 43802
M agnetic influence B SEN 60051
Safety IEC 414
Term inals C lam p strap M 4 up to 25A . C lam p strap M 8 for
over 25A
H um idity range U p to 95% R H (non condensing)
Test voltage @ 50H z 2kV R M S for 1 m inute
O verload A C current x 1.2 continuous x 10 for 5 seconds
O verload A C voltage x 1.2 continuous x 2 for 5 seconds
Frequency See m ain pages for other instrum ents
D am ping tim e Less than 3 seconds is standard. M ore heavily
dam ped m ovem ents are available on request.
Standard calibration 23C
O perating tem perature -20C to -60C
Enclosure code IP54 as standard (to B SEN 60529). For IP55 consult
w ith factory.
Term inals IP20B w ith term inal cover or term inal
boots fitted
C ase G rade U L94V0
B ase G rade U L94V1
Specifications
9
DIN 16257 symbol meaning for
calibration position
Vertical
H orizontal
Inclined 60
Inclination of dial surface from a
horizontal plane, e.g. 60
R equired orientation m ust alw ays be
stated w hen ordering if other than
vertical m ounting is required.
Specifications Continued
Dimensions
C ase D im ensions and panel cutout conform to IEC 473,
D IN 43700. M odels 242, 243 and 244 have injection
m oulded cases and bezels in flam e retardant
engineering therm oplastic, recognised by U nderw riters
Laboratory m aterials specifications. A ll 246 m odels
have pressed steel cases.
B ezel Slim -line D IN 43802, black as standard
B ezel w indow Standard sheet glass, w ith zero adjusters w here
appropriate. N on reflecting glass or polycarbonate
shatterproof w indow s are available.
Installation Installations in sw itchboard panel or m osaic
arrangem ent on equipm ent or m achine w ith a panel
thickness of up to 40m m in a horizontal or vertical
plane. Installation C ategory III
Fixing on panel M odels 242, 243 and 244 2 corner fixing clam ps
and tensioning thum b screw s.
M odel 242 available w ith a one piece push onclam p.
M odel 246 2 side fixing spring clips.
M ounting position N orm al vertical m ounting or as indicated on the scale
in accordance w ith D IN 16257. A deviation of 15 is
perm issible.
A pprovals Lloyds Shipping (LR S), B ureau Veritas (B V), EM C and LVD
Model 242 243 244 246
B ezel A 48 x 48 72 x 72 96 x 96 144 x 144
Panel cut-out B 45 x 45 68 x 68 92 x 92 138 x 138
Scale length: 90 42 65 94 145
Scale length: 240 72 112 150 230
Maximum overall depth C:
A m m eters and voltm eters A C and D C * 64 64 64 60
A m m eters and voltm eters w ith sw itch* 64
D ual m eters* 64
Elapsed tim e m eter/hours run* 64 64 64
M axim um dem and indicator* 64 64 60
C om bined M D I and M I indicator* 64 60
M axim um dem and indicator w ith relay* 90
Frequency m eter 90* 64 64 64 60
Frequency m eter 240* 120 125
Phase angle, pow er factor m eter 90* 107
240* 107
M .C . indicator w ith separate transducer* 64 64 64 60
D ynam om eter 360 synchroscope* 120 125
D ynam om eter 360 pow er factor m eter* 120
Phase sequence indicator* 64 64
Position indicator* 120 125
Speed indicator* 64 64 64 60
Tem perature indicators* 120 125
Q uadra m eters* 64
Im pulse counters* 64 64 64
W attm eter, VA rm eter 90 107 125
W attm eter, VA rm eter 240 107 125
M odel 244-21Y and 244-21Z 142
LED synchroscope and synchro check relay 80
LED 360 synchroscope 80
Indicator only
* If separate term inal cover is used, add 20m m to dim ension C .
N ot available
Panel cut-out
M axim um panel
thickness 10m m
B
B
A
A
C
10
Connections
AC Ammeter
AC Voltmeter
Moving Iron AC Ammeters and Voltmeters
D esigned to m easure A C current or voltage, these m eters indicate true
R M S values and are substantially independent of system w aveform .
Scales are calibrated dow n to 20% , and am m eters can have overload
scales x2, x3, x5 or x6 for m otor start duty. A m m eters can be supplied
for use w ith -/1A or -/5A current transform ers, w hilst voltm eters can be
scaled for use w ith voltage transform ers. H eavy dam ping is available as
an option. M eters can be used to m easure D C at reduced accuracy.
A ccuracy: C lass 1.5
Frequency: 50 or 60H z, (400H z on request)
B urden at 50H z: A m m eters: 1.5VA
Voltm eters: 4.5VA m axim um
R atings: A m m eters: 0.5 - 25A A C D C
M axim um system voltage 720V A C Low load / high
m iddle (m axim um 10A )
Voltm eters: 6 - 600V A C
B ezel size m m 48 72 96 144
Scale length m m 72 112 150 230
Product codes
A m m eter 242-03A 243-03A 244-03A 246-03A
x2 overload am m eters 242-032 243-032 244-032 246-032
x3 overload am m eters 242-033 243-033 244-033 246-034
x5 overload am m eters 242-035 243-035 244-035 246-035
x6 overload am m eters 242-036 243-036 244-036 246-036
Low load am m eters 243-03H 244-03H
Voltm eter 242-03V 243-03V 244-03V 246-03V
Product Codes Long Scale
Specifications Long-Scale Meters
11
DIN Panel Meters Long scale and Dual
Frequency Meters
Frequency m eters use an integral electronic converter and a m oving coil
indicator. These m eters are easy to read w ith an accuracy of C lass 0.5.
Dual AC Ammeters and Voltmeters
The tw o instrum ents in one case can be used for the independent
m easurem ent of tw o param eters or the com parison of tw o inputs.
O ften used w hen an A C generator is to be connected in parallel w ith
m ains supply w here voltage, phase and frequency m ust coincide.
Product Codes
Specifications
B ezel size m m 48 72 96 144
Scale length m m 72 112 145
Product codes 242-053 243-053 244-41L 246-41L
+ 253-TH Z + 253-TH Z
Product Codes
Specifications
Connections
A ccuracy: C lass 0.5
R atings: 100-125V A C
200-250V A C
380-440V A C *
500V A C *
*For voltages above 380V, use 242-013 substituting
253-TH Z, in place of 242-41S.
M odels available for use w ith VTs.
Frequency 0.5% : 45/55H z,
55/65H z,
45/65H z,
360/440H z
O ther scalings available on request.
B urden: 4VA m axim um
A ccuracy: 1.5% ES
R atings: A m m eter: 250A - 10A A C
Voltm eter: 15 - 600V direct connected
Frequency: 50/60H z (single frequencies 25H z to 3kH z on request)
B ezel size m m 96
Scale length m m 65
Product codes
A m m eters 244-80F
Voltm eters 244-80L
Dual AC Ammeter
Direct Connected
Dual AC Voltmeter
12
Connections
AC Ammeter
AC Voltmeter
Connections
DIN Panel Meters Long-Scale and Dual
Moving Coil Rectified AC Ammeters and Voltmeters
For high frequency or linear full scale A C m easurem ents, these
instrum ents m easure average values of sinusoidal w aveform s and are
scaled in R M S values.
The high quality silicon bridge rectifier gives a linear scale dow n to near
zero, w here som e com pression occurs.
Dual Frequency Meters
Tw o instrum ents in one case can be used to m easure a w ide range of
frequencies. These dual instrum ents save both panel space and assem bly
tim e. The 244-41D is an ideal com ponent in synchronising applications.
B ezel size m m 48 72 96 144
Scale length m m 72 112 150 230
Product codes
A m m eters 242-05B 243-05B 244-05B 246-05B
Voltm eters 242-05W 243-05W 244-05W 246-05W
Product Codes Long-Scale
Specifications Long-Scale
A ccuracy: 1.5-% ES
R atings: A m m eters: 250A -1A A C . U p to 30A on m odels 244/246-05B
Voltm eters: 15 - 600V direct connected
M odels available for use w ith VTs
Frequency: 50/60H z. (Single frequencies 25H z to 3kH z on request)
B ezel size m m 96
Scale length m m 65
Product code 244-41D
Product Code
Specifications
A ccuracy: C lass 0.5
R atings: 100 - 125V A C
200 - 250V A C
380 - 440V A C
500V A C
M odels available for use w ith VTs
Frequency 0.5% : 45/55H z,
55/65H z,
45/65H z,
360/440H z
B urden: 4VA m axim um
13
Features
Integral selector sw itch
True R M S m easurem ent
Slide-in dials
Scaled for custom er VT or C T
prim ary values
D IN 72 and D IN 96 m odels
Term inal cover as standard
Shock resistant sprung pivot and
jew el m ovem ent
x2 overload am m eters
Benefits
Space and tim e saving
C om petitive cost
Local indication
Ease of installation
Low m aintenance
C ustom ised options and features
Applications
Sw itchgear
D istribution system s
G enerator Sets
C ontrol panels
Energy m anagem ent
B uilding m anagem ent
Compliant with
IEC 61010-1B 2001, EM C and LVD
DIN Panel Meters
Moving Iron AC Ammeters and Voltmeters
with Selector Switch
C rom pton Instrum ents, a business unit of Tyco Electronics, is pleased to
add the new m oving iron A C am m eter and voltm eter w ith selector sw itch to
its com prehensive range of panel m eters. These 96m m and 72m m units
offer C lass 1.5 true R M S m easurem ent of three-phase A C voltage or current
w ith various sw itch notation options. The integral selector sw itch elim inates
the necessity for a separate selector sw itch, saving valuable panel space
and providing installation benefits. B oth am m eters and voltm eters feature a
slide-in dial, scaled for VT or C T values to suit application prim ary values.
These robust m oving iron m eters incorporate a clapper type repulsion
design w hich utilises a pivot, hairspring and jew el m ovem ent. The bottom
jew el is oil filled to provide dam ping w hile the top is sprung for resilience.
Voltm eters are m anufactured w ith internal voltage dropper resistors.
Product Codes AC Voltmeters with Selector Switch
Product Codes AC Ammeters with Selector Switch
Product Codes Options
Code Case Full scale Switch notation 3-
size deflection Phase
E243-02Q -G -PM **-C7-SW 6 72m m 0/120 V AC 0FF L1L2 L2L3 L3L1 3W
E243-02Q -G -PZ**-C7-SW 6 72m m 0/150 V AC 0FF L1L2 L2L3 L3L1 3W
E243-02Q -G -PZ-PZ-C7-SW 6 72m m 0/150 V AC 0FF L1L2 L2L3 L3L1 3W
E243-02Q -G -RX-RX-C7-SW 6 72m m 0/300 V AC 0FF L1L2 L2L3 L3L1 3W
E243-02Q -G -SF-SF-C7-SW 3 72m m 0/500 V AC L1L3 L1L2 L2L3 L3N L2N L1N 4W
E243-02Q -G -SJ-SJ-C7-SW 3 72m m 0/600V AC L1L3 L1L2 L2L3 L3N L2N L1N 4W
E244-02Q -G -PZ**-C7-SW 6 96m m 0/150 V AC 0FF L1L2 L2L3 L3L1 3W
E244-02Q -G -PZ-PZ-C7-SW 6 96m m 0/150 V AC 0FF L1L2 L2L3 L3L1 3W
E244-02Q -G -RX-RX-C7-SW 6 96m m 0/300 V AC 0FF L1L2 L2L3 L3L1 3W
E244-02Q -G -SF-SF-C7-SW 3 96m m 0/500 V AC L1L3 L1L2 L2L3 L3N L2N L1N 4W
E244-02Q -G -SF-SF-C7-SW 3 96m m 0/600V AC L1L3 L1L2 L2L3 L3N L2N L1N 4W
**Insert applicable VT prim ary and secondary value, e.g. 15kV/110V.
Description
N on reflecting glass w indow
Polycarbonate shatterproof w indow
R ed supplem entary pointer, externally adjustable
R ed index m ark (triangle)
Please state any required options at tim e of ordering.
Code Case Full scale Switch notation
size deflection
E243-02E-G -LS**-C 7-A M P3 72m m 0/5 A A C O FF L1 L2 L3
E244-02E-G -LS**-C 7-A M P3 96m m 0/5 A A C O FF L1 L2 L3
E243-022E-G -LS**-C 7-A M P3 72m m 0/5/10A A C O FF L1 L2 L3
E244-022E-G -LS**-C 7-A M P3 96m m 0/5/10A A C O FF L1 L2 L3
E243-02E-G -LA **-C 7-A M P3 72m m 0/1 A A C O FF L1 L2 L3
E244-02E-G -LA **-C 7-A M P3 96m m 0/1 A A C O FF L1 L2 L3
E243-022E-G -LA **-C 7-A M P3 72m m 0/1/2A A C O FF L1 L2 L3
E244-022E-G -LA **-C 7-A M P3 96m m 0/1/2A A C O FF L1 L2 L3
**Insert applicable C T prim ary value.
14
Specifications
Dimensions
Connections
AC Ammeters with Selector Switch
AC Voltmeters 3-Phase 3-Wire
AC Voltmeters 3-Phase 4-Wire
A ccuracy: 1.5% of full scale deflection (FSD )
Input rating: A m m eter: 1A , 5A 1/2A or 5/10A m oving iron, direct
connected Voltm eter: 120, 300, 500 and 600V A C
Frequency: 50 or 60H z (400H z on request)
B urden at 50H z: A m m eters: 0.5VA
Voltm eters: 4-5VA m ax
O verload am m eter: 2 x In continuous for 2 m inutes, 4 x In for 1 m inute
O verload voltm eter: 1.2 x continuous
2 x for 5 seconds
M ovem ent: M oving iron shock resistant sprung pivot and jew el
Scale length: D IN 72: 54m m
D IN 96: 97m m
Enclosure style: Panel m ount to D IN 42700
Enclosure m aterial: G rade U L94 VO (Lexan 500R )
B ezel style: B lack m atte D IN 43802
W indow : Standard sheet glass
Term inals: M 4 captive screw clam p
Fixing: 2 corner fixing clam ps w ith tensioning thum b screw s
M ounting position: Vertical m ount to D IN 16257, inclination of dial surface
15%
D am ping tim e:
C om pliant w ith: IEC 61010-1B 2001, C A T III 600V, EM C and LVD
O perating tem perature: -20 to + 55C
Storage tem perature: -40 to + 75C
C alibration tem perature: 23C
R elative hum idity: 95% (non condensing)
D im ensions: 96D IN : 96m m high x 96m m w ide x 63m m deep
72D IN : 72m m high x 72m m w ide x 63m m deep
Panel cut-out: D IN 96: 92m m x 92m m
D IN 72: 68m m x 68m m
IP protection: IP40
W eight: E243-02E 275g E243-02Q 300g
E244-02E 360g E244-02Q 390g
72DIN Models
96DIN Models
15
D isplay: 99999.99
Voltage: 100-125V A C
200-250V A C
380-440V A C
Frequency: 50 or 60H z
B urden: 2.5VA for D C input m odels
Voltage: 10/27V (12, 24V) D C
38/58V (48V) D C
90/132V (110V) D C
Connections
Elapsed Time/Hours Run Meters AC
Elapsed Time/Hours Run Meters DC
DIN Panel Meters
ETM and Impulse Counters
Elapsed Time or Hours Run Meters
Elapsed tim e m eters (ETM ) or hours-run m eters m onitor "O N /R U N " tim e
of plant and equipm ent, allow ing the user to effectively control
production efficiency, cost estim ation and service period m onitoring for
preventative m aintenance. Tim e is m easured in increm ents of 0.01h up
to 99999.99 hours after w hich the m eter autom atically resets to zero.
M eters are non resettable before this tim e to prevent accidental resetting.
A ccuracy: Pulse for pulse
D isplay: 6 digit 999999
R atings: 110, 120, 220, 230, 240, or 415V A C 10%
50/60H z
12V or 24V D C 10%
B urden: 0.75VA (110V A C )
2.70VA (415V A C )
80m W (12V D C )
Pulse w idth: 50m s m inim um
M ark/space ratio: 1:1
Impulse Counters
Im pulse counters can be used to m easure any param eter w here there is
an applicable pulse that is directly proportional to the m easured param eter.
For exam ple, the num ber of m otor starts can be recorded by using a
com bination of Paladin transducers, kW h, am pere hour, VA hour. The
counter registers one digit every tim e an on/off voltage pulse is applied to
the input term inals, and is non resettable to prevent accidental resetting.
B ezel size m m 48 72 96
Scale length 99999.99h 99999.99h 99999.99h
Product codes
50H z 242-158 243-155 244-155
60H z 242-159 243-156 244-156
D C input 242-157 243-151 244-151
Product Codes
Specifications
B ezel size m m 48 72 96
Scale length 999999 999999 999999
Product codes
DC input
12V 242-259G -M U 243-259G -M U 244-259G -M U
24V 242-259G -B D 243-259G -B D 244-259G -B D
AC input
110V 242-259G -PM 243-259G -PM 244-259G -PM
120V 242-259G -PQ 243-259G -PQ 244-259G -PQ
220V 242-259G -R 4 243-259G -R 4 244-259G -R 4
230V 242-259G -R Q 243-259G -R Q 244-259G -R Q
240V 242-259G -R R 243-259G -R R 244-259G -R R
380V 242-259G -R U 243-259G -R U 244-259G -R U
415V 242-259G -SB 243-259G -SB 244-259G -SB
Product Codes
Specifications
16
DIN Panel Meters Quadra
Quadra 3-in-1 and 4-in-1
The Q uadra range of 96m m
2
D IN style 3-in-1 and 4-in-1 m eters offer
reduced stock holding and savings on space, installation and
com m issioning. Ideally suited for generator set applications, the range
offers m easurem ent of A C and D C , current and voltage, frequency or
elapsed tim e. O ptions include custom er logo on dial, coloured dial, panel
m ounting gasket and heavily dam pened m ovem ents.
Product Codes
Specifications
Product Codes
Voltm eter: 110, 120, 200, 230, 240, 380, 400, 415, 440, 480V A C
nom inal. M axim um end scale 600 volts
Frequency m eter inputs: 45/55H z, 55/65H z, 45/65H z, 360/440H z
Voltage inputs: Sam e as voltm eter inputs above
A m m eter inputs: 10m A A C 1 or 5A input (internal C T)
H ours run: 110, 120, 220, 230, 240, 380, 400, 415, 440 volts
50 or 60H z
H our run counting range: 99999.99 hours
D C current: 250A - 1A D C including 1, 5, 10, 20 and 4-20m A
D C for transducer inputs
D C volts: 50m V to 600V D C including 50, 60, 75 and 150m V
for shunt inputs
B urden: C urrent: 0.75VA per phase
H ours run: 2.5VA
LC D hours run: 0.5VA
Voltage: 0.5VA
Frequency: 4VA
Code Description
244-80C A C V + D C I + A C A + D C A
244-80D 3 x D C I + D C ETM (LC D )
244-80G 3 x A C A
244-80H 3 x A C V + FR Q
244-80I 3 x A C A + ETM
244-80J 3 x A C A + ETM (LC D )
244-80K FR Q + A C V + D C I
244-80N A C A + A C V + FR Q + ETM
244-80P 3 x A C V
244-80Q A C V // FR Q // ETM + A C A
244-80R A C V // ETM + 2 x A C V
244-80S 2 x A C V + 2 x A C A
244-80T FR Q // ETM + A C V
244-80U 3 x A C A + A C V
244-80W ETM // FR Q + D C I + A C V
244-80X 4 x D C I
244-80Y ETM // FR Q + D C I
244-80Z A C V + A C A + FR Q // ETM
244-802 2 x A C V + A C A + ETM
244-803 A C V + FR Q + 2 x A C A
244-804 3 x A C A + D C I
244-806 3 x A C V + A C A
244-807 V, H z, ETM + SW ITC H
A C V = R ectified A C voltm eter
A C A = R ectified A C am m eter
D C A = D C am m eter
D C I = D C indicator
ETM = Elapsed tim e m eter
ETM (LC D ) = LC D elapsed tim e m eter
FR Q = Frequency m eter
// = In parallel w ith
W hen ordering please specify the inputs for each param eter and the scaling required.
17
Quadra 3-in-1 and 4-in-1
Connections
244-80H
Terminals
1 Volt neutral L3
3 Volt live L3
5 Frequency neutral
6 Volt live L2
7 Frequency live
8 Volt neutral L1
9 Volt live L1
11 Volt neutral L2
244-80I
Terminals
1 N eutral hours run
3 Live hours run
5 C urrent start red L1
10 C urrent finish black L1
11 C urrent start red L3
7 C urrent finish black L3
9 C urrent start red L2
8 C urrent finish black L2
244-80J
Terminals
1 C urrent start red L1
3 C urrent finish black L1
2 Live hours run
4 N eutral hours run
6 C urrent start red L2
8 C urrent finish black L2
9 C urrent start red L3
7 C urrent finish black L3
244-80Q
Terminals
1 Live hours run
5 Live volts and
frequency
7 N eutral
8 C urrent start red
9 C urrent finish black
244-80T
Terminals
1 Voltm eter input
3 Voltm eter input
5 H ours run and frequency m eter input
6 H ours run and frequency m eter input
244-80X
Terminals
2 Positive D C 2
3 Positive D C 3
4 N egative D C 2
5 N egative D C 3
6 Positive D C 1
7 Positive D C 4
8 N egative D C 1
11 N egative D C 4
18
Connections
DC Ammeter
DC Voltmeter
Connections
Dual DC Ammeter
Dual DC Voltmeter
DIN Panel Meters
Moving Coil DC Ammeters and Voltmeters
M oving coil m eters are suitable for all D C system s. The linear scale is
calibrated dow n to zero and accuracy m aintained dow n to 10% .
H igh currents are m easured w ith separate shunts and suitably scaled
indicators. Suppressed, centre and offset-zero m odels are available.
Moving Coil Dual DC Ammeters and Voltmeters
D ual instrum ents can be used to m easure a w ide range of currents and
voltages, and save both space and tim e by requiring only one panel
cut-out. The 244-80M allow s for independent m easurem ent of tw o D C
currents in one case. The 244-80E allow s for independent m easurem ent
of tw o D C voltages in one case.
A ccuracy: C lass 1.5
R atings: A m m eters: 100A -25A , (200A for 05 m odel)
4/20m A suppressed zero
40A for m odel 243/244-01A
Voltm eters: 50m V-600V
1/5V suppressed zero
50, 60, 75, 100, 150m V for use w ith shunts
Im pedance: A m m eters: 75m V internal shunt above 60m A
Voltm eters: 1000/V above 1V
A ccuracy: C lass 1.5
R atings: D C C urrent: 100A -25A direct connected
4/20m A suppressed zero.
D C volts: 50m V-600V
1/5 volt suppressed zero
50, 60, 75, 150m V for use w ith shunts.
B ezel size m m 96
Scale length m m 94
Product codes
A m m eters 244-80M
Voltm eters 244-80E
B ezel size m m 48 72 96 144
Scale length m m 72 112 150 230
Product codes
A m m eter 242-05A 243-05A 244-05A 246-05A
A m m eters suppressed zero 242-05R 243-05R 244-05R 246-05R
Voltm eters 242-05V 243-05V 244-05V 246-05V
Voltm eters suppressed zero 242-05S 243-05S 244-05S 246-05S
Product Codes Long-Scale
Specifications
Product Codes Long-Scale
Specifications
Further details available on request.
19
DIN Panel Meters
Temperature and Process Indicators
Temperature Indicators
Long-scale indicators are used to read tem perature values, usually
rem otely w ith R TD or therm ocouple sensors supplied by the custom er.
R TD (R esistance Tem perature D etector) indicators m easure the change
in the sensor resistance. A 2- or 3-w ire system m ay be used.
Therm ocouple indicators accept standard m illivolt input signals. C old
junction com pensation is provided and therm ocouple break indication is
incorporated into the instrum ent.
Process Indicators
Instrum ents used to check process functions both locally or rem otely at
centralised controls. These m oving coil instrum ents offer a w ide variety
of electrical and m echanical readouts operated by transducer,
tachogenerator, therm ocouple, resistance bulb or other D C analogue
signals. Suppressed, centre and offset zero m odels are available on request.
B ezel size m m 96 144
Scale length m m 150 230
Product codes
R TD 244-45R 246-45R
Therm ocouple 244-45T 246-45T
Product Codes
Specifications
Connections
Thermocouple Indicators -45TG
RTD Indicators -45RG
Connections
A ccuracy: C lass 1.5 - indicator only. R TD indicator suitable for
10 copper 100 platinum , 100 and 120 nickel
sensors. Pow er in R TD is around 100W .
Therm ocouple indicator suitable for J (0-700C ),
K (0-1200C ). 50 m axim um circuit resistance.
A uxiliary supply: M odel 45R : from 63.5-480V A C at 50/60H z.
M odel 45T: 110, 115, 220, 240, 380, 400, 480V A C
and 12, 24, 48, 110, 125V D C .
B urden: -45R 2VA , -45T 3VA
A ccuracy: C lass 1.5
R atings: 1, 2, 5, 10 and 20m A . 4/20m A suppressed zero
B urden: See technical data sheet T118
B ezel size m m 48 72 96 144
Scale length m m 72 112 150 230
Product codes
A C current 242-05A 243-05A 244-05A 246-05A
A C voltage 242-05V 243-05V 244-05V 246-05V
Speed 242-052 243-052 244-052 246-052
Frequency 242-053 243-053 244-053 246-053
Phase angle 242-054 243-054 244-054 246-054
W atts 242-055 243-055 244-055 246-055
VA r 242-056 243-056 244-056 246-056
VA 242-057 243-057 244-057 246-057
Product Codes Long-Scale Models
Specifications
20
Connections
Tap position indicator with self-
contained power source
Connections
Phase Sequence Indicators
DIN Panel Meters
Tap Position and Phase Sequence
Moving Coil Tap Position Indicators
Long-scale position indicators are used to m onitor transform er tap, hoist
or valve positions. They em ploy a 3-w ire system and 11 to 18 positions
can be provided using 400 steps. The m easuring system is m ade up
ofa m oving coil indicator, stabilised pow er supply and transducer.
Indicators can accept user-supplied rem ote potentiom eter or resistance
therm om eter sensors.
Phase Sequence Indicators
Electronic phase sequence indicators ensure correct phase rotation and
the presence of all 3-phase supplies. Incorrect or loss of phase can cause
serious dam age in a w ide range of electrical m achines. Ship-to-shore
supplies, m obile generators and rem ote installations are particularly
vulnerable to this problem .
B ezel size m m 96 144
Scale length m m 150 230
Product codes
Position indicator 244-45P 246-45P
Product Codes
Specifications
A ccuracy: C lass 1.5
A uxiliary supply: A C 50, 110, 220, 240V, 50/60H z
D C 50, 110, 125, 220V, 15%
B urden: 2VA
B ezel size m m 72 96
Product codes
Phase sequence indicator 243-12P 244-12P
Product Codes
Specifications
Voltage: 151/300V, 301/500V
100/150V (M odel 244-12P only)
Frequency: 50/60H z
B urden: 2.5VA /phase
21
DIN Panel Meters Phase Angle Meters
Electronic Phase Angle Meters
Phase angle m eters indicate the phase displacem ent betw een current
and voltage. They are used in applications w here the phase angle m ust
be m onitored, for exam ple w ith tariffs having VA r penalties, or to
optim ise generator pow er delivery.
The m easuring system includes a m oving coil indicator and a phase angle
transducer. The 244 and 246 m odels are self contained.
A ccuracy: C lass 2.5 (2 electrical)
R atings: C urrent: 1A or 5A for C Ts.
Voltage: 100/130V, 200-250V and 380-450V,
100-110 for VT use.
Frequency: 50H z, 60H z, 400H z.
B urden at 50H z: C urrent: 1VA
Voltage: 4VA per phase
C urrent range: 20-125%
B ezel size m m 72 96 144
Scale length m m 65 94 145
Product codes
Single phase E243-014-G -FA + 244-42B 246-425
256-TPS
3-phase 3/4 w ire E243-014-G -FA + 244-42A 246-42A
balanced load 256-TPT
Product Codes Short-Scale Models
Specifications
B ezel size m m 72 96 144
Scale length m m 112 150 230
Product codes
Single phase 243-054G -FA + 244-425 246-425
256-TPS
3-phase 3/4 w ire 244-427 246-427
balanced load
Product Codes Long-Scale Models
Connections
Single Phase Systems
3-Phase, 3-4-Wire Balanced Systems
22
DIN Panel Meters
360 Power Factor Indicator
360 Dynamometer Power Factor Indicators
Pow er factor indicators are suitable for generators or supplies operating
in parallel. The four quadrant 360 scale calibrated cos 0-1-0-1-0
indicates forw ard (export) and reverse (im port) pow er flow for inductive
and capacitive loads.
A ccuracy: C lass 2.5 (2 electrical)
R atings: C urrent: -/1A or -/5A for C Ts
Voltage: 60-600V, 100/110 for VT use.
Frequency: 50H z or 60H z
B urden: C urrent: 2VA per coil @ 50H z
Voltage: 4VA per coil @ 50H z (7.5VA > 250V)
B ezel size m m 96 144
Scale length 360 360
Product codes
Single phase 244-137 246-137
3-phase 3- or 4-w ire 3-currents + 1 voltage 244-131 246-131
3-phase 3- or 4-w ire 1-current + 3 voltages 244-132 246-132
3-phase 3- or 4-w ire, unbalanced load 244-136 246-136
Product Codes
Specifications
Connections
Single Phase
3-phase 3- or 4-wire 1-current 3-voltages, balanced load
3-phase 3- or 4-wire, unbalanced load
3-phase 3- or 4-wire 3-voltage, balanced load
3-phase 3-wire using two CTs, unbalanced load
23
DIN Panel Meters Synchscope
360 Dynamometer Synchroscope
W here m anual parallelling of tw o A C system s is necessary, the
frequency of both system s can be m onitored by a synchroscope.
The system s are synchronised w hen the pointer is stationary in the
12 o'clock position. The instrum ent uses silicon oil dam ping and is rated
for continuous operation and connection.
A ccuracy: C lass 2.5 (2 electrical)
R atings voltage: 100-125V, 200-250V, 380-450V*
* U se transform er box 855-954 100-110V for VT use
Frequency: 50H z, 60H z, 50/60H z, 400H z
B urden at 50H z: 5VA m axim um .
B ezel size m m 96 144
Scale length 360 360
Product codes
50H z 244-145 246-145
60H z 244-146 246-146
50/60H z 244-147 246-147
400H z 244-144 246-144
Product Codes
Specifications
Connections
24
Connections
360 LED Synchroscope
360 LED Synchroscope and Synchro
Check Relay
DIN Panel Meters LED Synchroscope
360 LED Synchroscope and Synchro Check Relay
W here m anual parallelling of tw o A C system s is desired, the frequency
of both system s can be m onitored by an LED synchroscope.The system s
are synchronised w hen the green LED is lit in the 12 oclock position.
The instrum ent is rated for continuous operation and connection. For the
sem i-autom atic parallelling of tw o A C system s, the voltage, phase
displacem ent and the frequency of both system s can be m onitored by
this LED synchroscope and synchro check relay. C ontrols for voltage,
phase angle, and tim e delay are provided. The system s are synchronised
w hen the green triangular LED s are lit together w ith the G EN /B U S green
LED s. A dead bus option is also available.
R atings voltage: 63.5, 110, 120, 220, 230, 240, 380, 400, 415, 440, 480V
110/120V (115V nom inal)
220/240V (230V nom inal)
380/480V (430V nom inal)
Volts A C or via VT
Frequency: 40/65H z
B urden at 50H z: 4VA m axim um
Suitable for single or three phase system s
Safety: IEC 1010-1 (300V A C R M S installation degree 2)
D ielectric: 4kV rm s for 1 m inute
Isolation: B U S/G EN /R ELA Y
Vibration: To Lloyds shipping specification
*Phase difference: + 0-20, + /-1
*Voltage difference: + 0-20% , + /-2%
0-10% for m odels G and H
*Tim e delay: 0-2.5 seconds + 10%
*A ccuracy: Synchronisation at T.D C is + 1
*O nly for the 360 LED synchroscope and synchro check relay.
B ezel size m m 96 96 96
Scale length m m 360 LED 360 LED 360 LED
3- or 4-w ire Synchroscope Synchroscope Synchroscope
40-65H z and synchro check and synchro
check relay
relay (dead bus)
Product codes
110/120V 244-14G G -PO B X 244-14H G -PO B X
220/240V 244-14G G -R 5B X 244-14H G -R 5B X
380/480V 244-14G G -R U B X 244-14H G -R U B X
63.5V 244-14A G -N XYY 244-14LG -N XB X 244-14D G -N XB X
110V 244-14A G -PM YY 244-14LG -PM B X 244-14D G -PM B X
220V 244-14A G -R 4YY 244-14LG -R 4B X 244-14D G -R 4B X
230V 244-14A G -R Q YY 244-14LG -R Q B X 244-14D G -R Q B X
240V 244-14A G -R R YY 244-14LG -R R B X 244-14D G -R R B X
380V 244-14A G -R U YY 244-14LG -R U B X 244-14D G -R U B X
400V 244-14A G -SC YY 244-14LG -SC B X 244-14D G -SC B X
415V 244-14A G -SB YY 244-14LG -SB B X 244-14D G -SB B X
440V 244-14A G -SH YY 244-14LG -SH B X 244-14D G -SH B X
480V 244-14A G -SEYY 244-14LG -SEB X 244-14D G -SEB X
For the 244-14L and 244-14D m odels, the generator voltage is com pared to the
nom inal input (bus) voltage specified at tim e of ordering. For the 244-14G and
244-14H m odels, the generator voltage is com pared to the m easured bus voltage.
Product Codes
Specifications
25
DIN Panel Meters Power
Wattmeters and VArmeters
The 244/246 m odels are self contained and able to m easure active and
reactive pow er in both balanced and unbalanced, single and 3-phase
3-or4-w ire system s. W attm eters are ideal for clear precise analogue
indication of pow er in applications such as pow er generation, industrial
control panels and pow er distribution.
B ezel size m m 72 96 144
Scale length m m 65 95 145
Wattmeters product code
Single phase E243-015-G -FA + 256-TW K 244-210 246-210
3-phase 3-w ire balanced load E243-015-G -FA + 256-TW L 244-211 246-211
3-phase 4-w ire balanced load E243-015-G -FA + 256-TW H 244-21C 246-21C
3-phase 3-w ire unbalanced load E243-015-G -FA + 256-TW M 244-213 246-213
3-phase 4-w ire unbal. star C T E243-015-G -FA + 256-TW N 244-214 246-214
3-phase 4-w ire unbal. delta C T E243-015-G -FA + 256-TW J 244-21E 246-21E
3-phase 4-w ire 3-elem ent E243-015-G -FA + 256-XW W 244-21Y 246-21Y
VArmeters product codes
3-phase 3- or 4-w ire balanced load E243-016-G -FA + 256-TXG 244-310 246-310
3-phase 3-w ire unbalanced load E243-016-G -FA + 256-TXM 244-31S 246-31S
3-phase 4-w ire unbal. star C T E243-016-G -FA + 256-TXN 244-314 246-314
3-phase 4-w ire unbal. delta C T E243-016-G -FA + 256-TXJ 244-31E 246-31E
Product Codes Short-Scale Models
Specifications
B ezel size m m 72 96 144
Scale length m m 112 150 230
Wattmeters product code
Single phase 243-055G -FA + 256-TW K 244-215 246-215
3-phase 3-w ire balanced load 243-055G -FA + 256-TW L 244-216 246-216
3-phase 4-w ire balanced load 243-055G -FA + 256-TW H 244-21D 246-21D
3-phase 3-w ire unbalanced load 243-055G -FA + 256-TW M 244-218 246-218
3-phase 4-w ire unbal. star C T 243-055G -FA + 256-TW N 244-219 246-219
3-phase 4-w ire unbal. delta C T 243-055G -FA + 256-TW J 244-21F 246-21F
3-phase 4-w ire 3-elem ent 243-055G -FA + 256-XW W 244-21Z 246-21Z
VArmeters product codes
3-phase 3- or 4-w ire balanced load 243-056G -FA + 256-TXG 244-315 246-315
3-phase 3-w ire unbalanced load 243-056G -FA + 256-TXM 244-31L 246-31L
3-phase 4-w ire unbal. star C T 243-056G -FA + 256-TXN 244-319 246-319
3-phase 4-w ire unbal. delta C T 243-056G -FA + 256-TXJ 244-31F 246-31F
M odels E243-015, E243-016, E243-055 and E243-056 use a separate transducer.
C rom pton transducers are ideal for this application. O ur product code reference
assum es a 1m A output. O ther outputs of 5, 10, 20 or 4/20m A can also be used.
Product Codes Long-Scale Models
A ccuracy: Short-scale: C lass 2.5 Long-scale: C lass 1.5
M easuring ranges: Voltage: 94-106%
C urrent: 0-120%
Frequency influence: 0.4% H z
R ating: C urrent: 0.2-5A , direct connected 1A -5A for C Ts.
Voltages: 57.7-480V
O verload: 120% of nom inal continuous voltage up to 600V m axim um
M axim um input: 600V
Frequency: 50H z or 60H z
Pow er factor: U nity pow er factor assum ed range 0.5/1/0.5
B urden: C urrent: 1VA per phase
Voltage: 1VA per phase
W arm -up tim e: < 15 m inutes
26
Wattmeter Connection Diagrams
Single Phase
224-210, 244-215, 246-210, 246-215
3-phase 4-wire balanced load
244-21C, 246-21C, 244-21D, 246-21D
3-phase 3-wire balanced load
244-211, 246-211, 244-216, 246-216
3-phase 3-wire unbalanced load 2-element
244-213, 246-213, 244-218, 246-218
DIN Panel Meters Power
27
Wattmeter Connection Diagrams
3-phase 4-wire unbalanced load star connected CTs 2
1
/2-element
244-214, 246-214, 244-219, 246-219
3-phase 4-wire unbalanced load delta connected CTs
244-21E, 246-21E, 244-21F, 246-21F
3-phase 4-wire unbalanced load star connected CTs 3-element
244-21Y, 246-21Y, 244-21Z, 246-21Z
28
VArmeter Connection Diagrams
3-Phase 3- or 4-Wire Balanced Load, 1-Element
244-310, 246-310, 244-315, 246-315
3-Phase 4-Wire Unbalanced Star Connected CTs, 2
1
/2-Element
244-314, 246-314, 244-319, 246-319
3-Phase 3-Wire Unbalanced Load, 2-Element
244-31S, 246-31S, 244-31L, 246-31L
3-Phase 4-Wire Unbalanced Delta Connected CTs, 2
1
/2-Element
244-31E, 246-31E, 244-31F, 246-31F
DIN Panel Meters Power
29
Loading capacity: SO 1 and SO 2: 20A , 500V. SO 3: 12A /480V
Sw itching capacity: 3kW at 220V, 5kW at 380V, 5.5kW at 500V
Isolating voltage: SO 1 and SO 2: 500V A C . SO 3: 480V A C
O perating tem perature: -20C to + 70C
M ounting installation: Tw o point front fixing
D im ensions: 48m m x 48m m
Panel cut out: 3 drilled holes
C om pliant w ith: LVD and EM C
IP protection: SO 1 and SO 2: IP65. SO 3: IP54
SO1 Three hole fixing 20A
SO 1-SA B 4-position am m eter sw itch, L1-L2-L3-0
SO 1-SA A 4-position am m eter sw itch, R -Y-B -O
SO 1-SVE 7-position voltm eter sw itch, R Y-YB -R B -0-R N -YN -B N
SO 1-SVD 7-position voltm eter sw itch, L1L2-L2L3-L3L1-0-L1N -L2N -L3N
SO2 Single hole mount 20A
SO 2-SA B 4-position am m eter sw itch, L1-L2-L3-0
SO 2-SA A 4-position am m eter sw itch, R -Y-B -O
SO 2-SVE 7-position voltm eter sw itch, R Y-YB -R B -0-R N -YN -B N
SO 2-SVD 7-position voltm eter sw itch, L1L2-L2L3-L3L1-0-L1N -L2N -L3N
SO3 Three hole fixing 12A
SO 3-SA B 4-position am m eter sw itch, L1-L2-L3-0
SO 3-SVD 7-position voltm eter sw itch, L1L2-L2L3-L3L1-0-L1N -L2N -L3N
Connections
Voltmeter Change-over Switches
For m easuring 3-interconnected voltages
and 3-phase voltage against N .
SO1 and SO2
SO3
Ammeter-Change-over Switches
SO1 and SO2
SO3
Product Codes
Dimensions
SO1 Three Hole Fixing 20 Amp
Sw itch insert Front view Face plate Panel drilling
SO2 Single Hole Fixing 20 Amp
Sw itch insert Front view Face plate Panel drilling
SO3 Three Hole Fixing 12 Amp
Sw itch insert Face plate Panel drilling
Instrument Selector Switches
Panel m ounted selector sw itches offer a 7-position voltm eter sw itch and a
4-position am m eter sw itch for reading line-to-line or line-to-neutral voltage
and phase current. Each sw itch can be supplied w ith either num bered or
coloured annotation.
Specifications
30
070 Series ANSI Switchboard Meters
H igh quality range of sw itchboard instrum ents w ith C lass 1 accuracy and
w hich com plies w ith A m erican A N SI-C 39.1 (1981) specifications. A vailable
in 4
1
/2" and 8
3
/4" case sizes, their rugged design characteristics m eet the
needs of the m ost dem anding environm ental applications. This extensive
range of analogue and digital/analogue m eters utilises high shock oil
dam pened m ovem ents and provides 1% accuracy for all R M S A C and D C
ranges. The range offers various custom ised options and features.
Description
070 series offers tw o case sizes, 4
1
/2" (M odels 075, 077 and 078) and 8
3
/4" (M odel 079).
M odel 078 is high shock herm etically sealed and all m odels have heavy gauge pressed
steel cases. M ounting is by four integral studs.
M odels 075 and 077 are a one piece flam e retardant polycarbonate m oulding w ith a
black m atte finished bezel area, and a specially contoured w indow to m inim ise reflection
from adjacent light sources. M odel 079 has a black pressed steel bezel w ith a
toughened glass w indow , and M odel 078 has a die-cast bezel and a projecting m oulded
toughened glass w indow , w hich incorporates a gas tight zero adjuster.
Scales are 240 m oving iron and 250 m oving coil w ith parallax error-free platform dials.
Standard dials are w hite m atte w ith black printed scales and bar knife-edge pointers.
B lack dials w ith w hite or yellow scales and pointers are also available.
G eneral options include supplem entary red pointer (075 and 077), slave pointer,
calibration for non standard am bient tem peratures, special scales, trim potentiom eters,
and Illum inated dials w ith w hite or red light sources.
Perform ance: A N SI C 39.1 (1981)
A ccuracy: C lass 1
Term inals: 10-32 U N F term inals (M 5 screw clam p term inal for
M odel 075)
D ielectric voltage: W ithstand test 2.3kV for 1 m inute
R esponse tim e: A pproxim ately 2.5 seconds to full scale (077 and 078)
and 3.5 seconds (079)
O vershoot: 33% m axim um
Standard calibration: 23C
O perating tem perature: 0C to + 40C . M odel 078: -40C to + 70C .
Storage tem perature: -10C to + 50C
Extrem e tem p range: -20C -to + 65C
Enclosure integrity: M odels 075/077/079 to IP54(N EM A 3S) splash proof,
IP55 (N EM A 4) hoseproof is an optional extra
M odel 078 to IP67 (N EM A 6 and 6P)
Fixing on panel: 4 integral
1
/4 -28 U N F fixing studs
A pprovals: EM C and LVD , U L and A B S
Dimensions
D im ension E varies w ith m easured param eter - see product code table overleaf.
1 4 Fixing holes 8m m . 2 1/4-28 U N F fixing studs. 3 10-32 U N F Term inals (M 5
screw clam p term inal on m odel 075).
Model Panel cut-out Rear
view
Dia A B C D E F G
075 103 86 43 110 17 - 30 101
077 103 86 43 110 17 - 30 101
078 103 86 43 110 17 - 30 101
079 229 86 43 229 17 - 30 101
Features
R ugged H i-Q taut band suspension
C lass 1 accuracy
JIS dim ensioned product available
on request
Benefits
M eets all the requirem ents of
A N SI-C 39.1 (1981)
Parallax error-free platform dials
B um p, shock and vibration proof
C ustom ised options and features
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
B uilding m anagem ent
U tility pow er m onitoring
Process control
M otor control
Approvals
U L approved file no. E203000
A B S (A m erican B ureau of Shipping)
93-LD 17806-X
Specifications
31
Product Codes
Case codes
Type of instrument Ranges 075 077 078 079 Product codes
A C am m eter m oving iron 0.5-10A 56 56 - - 075/077-08A
A C am m eter m oving iron 0.5-10A - - 86 86 078/079-08A
A C am m eter m oving iron 10.1-30A - 86 86 86 077/078/079-08A
Slave pointer am m eter 1 or 5A 86 077-08D
6 x overload A C am m eter 5/30A - 30/180A - 86 86 86 077/078/079-086
A C voltm eter m oving iron 30-800V - 86 86 86 077/078/079-08V
A C rectified am m eter 1-30A 56 56 86 56 075/077/078/079-05B
A C rectified voltm eter 30-800V 56 56 86 56 075/077/078/079-05W
A C voltm eter expanded scale 110-130V - 86 86 86 077/078/079-05Y
A C R M S am m eter 1-30A 56 56 86 56 075/077/078/079-05F
A C R M S voltm eter 150-750V 56 56 86 56 075/077/078/079-05G
Slave pointer voltm eter 50-300V 86 077-05X
Elapsed tim e m eter (99999.99) 50 or 60H z / 100-440V* and D C - 56 56 - 077/078-155/156/077-151
Frequency m eter 50, 60
400H z/100-440V** 86 86 86 86 075/077/078/079-41L
A C w attm eter or VA rm eter 0.2-10A /100-440V* - 132 132 132 077/078/079-21 or 31
360 rotary pow er factor m eter 0.2-10A /100-600V - 132 132 132 077/078/079-13
360 rotary synchroscope 100/125V, 200/250, 380/450*** - 132 132 132 077/078/079-14
LED synchroscope only 63.5-480V**** - 86 - - 077-14A
LED synchroscope and
synchro check relay 63.5-480V**** - 86 - - 077-14
A C m eter relay A C 6V-500V, - 86 - - 077-30
100A -1A , 5A via C T (see M eter R elay section)
Phase sequence indicator 100-150, 151-300, 301-500V - 56 - - 077-12P
M axim um dem and Indicator 1 or 5A - 86 - - 077-16
Tap position indicator 1-18 steps. 400 - 86 - - 077-45P
Transducer operated indicator 1, 5, 10, 20, or 4/20m A 56 56 56 56 075/077/078/079-05
D C am m eter m oving coil 200A - 30A 56 56 56 56 075/077/078/079-05A
D C voltm eter m oving coil 50m V-600V 56 56 56 56 075/077/078/079-05V
D C m eter relay 100m V-500V, 10A -15A - 86 - - 077-30
(see M eter R elay section)
Tem perature indicator R TD - 86 86 86 077/078/079-45R
Tem perature indicator Therm ocouple - 86 86 86 077/078/079-45T
240 phase angle 1 or 5A , 100-400V
/pow er factor 50, 60 or 400H z - 132 132 132 077/078/079-42
Watt/hour indicators:
W att/hour indicator 1 or 5A / 69-277V**** - 132 - - 077-KH
Transducer operated 1, 5, 10, 20, or 4/20m A - 132 132 - 077-KH
Analogue/LED digital indicators
A C am m eter 1m A - 10A - 86 - - 077-D IB
A C voltm eter 200m V - 600V - 86 - - 077-D IW
A C w attm eter 69V/5A , 120V/5A , 50 or 60H z - 86 - - 077-D W
A C VA rm eter 120V/5A , 208V/5A , 50 or 60H z - 86 - - 077-D X
Phase angle m eter 69V/5A , 120V/5A , 50 or 60H z - 86 - - 077-D P
Frequency m eter 110/130V, 50 or 60H z - 86 - - 077-D Z
D C am m eter 1m A - 1A - 86 - - 077-D IA
D C voltm eter 20m V - 600V - 86 - - 077-D IV
Transducer indicator D C m A - 86 - - 077-D IT
Tachom eter A C or D C rated - 86 - - 077-D I2
* 100-440V = (100/125, 200/250, 380/440)
** 100-440V = (100/125, 200/250, 380/440). Frequencies 45/55, 55/65, 45/65, 47/53, 57/63, 360/440.
*** U sing transform er box 855-954
**** N om inal voltage to be specified
For specification and connection diagram s, please refer to equivalent m odels in 240 Series D IN Panel M eter section.
R eplace 244 w ith 077 etc., e.g. 244-210 becom es 077-210.
32
AC and DC Ammeters, Voltmeters
and Frequency Meters
This range of self contained, H i-Q , taut band m oving coil m eters feature
250 linear scale and oil dam pened m echanism s for superior perform ance
in high vibration situations. A C instrum ents are available w ith true R M S
converting circuit or R M S com pensated rectifier. W hile types of
frequency m eters can be dam aged by transient supply voltage spike.
C rom pton 077-41 frequency m eters can w ithstand, w ithout dam age,
10 successive transient spikes of 1250 volts. The range offers U L and
C SA approvals. JIS dim ensioned products are available on request.
A ccuracy: 1% full scale at 23C (73F)
Scale arc: 250 full scale deflection
Scale length: 077 and 078: 175.2 m m (6.9")
079: 353 m m (13.9")
Scale plate: 2 piece, platform type
R esponse tim e: 077 and 078: A pproxim ately 2.5 seconds to full scal
079: A pproxim ately 3.5 seconds to full scale
O perating tem perature: 0 to 40C (32 to 104F)
Storage tem perature: -10 to + 50C (14 to 122F)
Extrem e tem p range: -20 to + 65C (-4 to 149F)
Term inals: Standard 10-32 U N F stud. M 5 screw clam p is optional.
Position: Vertical (scale)
D ielectric w ithstand: 2300V A C for 1 m inute betw een electrical circuit
and case
O vershoot: 33% m axim um
Enclosure code: 077 and 079: IP54, optional IP55
078: IP67
A pprovals: EM C and LVD . U L approved file no. E203000
O verload rating: A C am m eters - 2 x continuous, 50 x for 1 second
A C voltm eters and frequency m eters - 1.2 x continuous
D C am m eters - 2 x continuous 10 x for 1 second
D C voltm eters - 1.2 x continuous
Frequency range: A C calibration 60H z 20%
Specifications Ammeters and Voltmeters
R esponse tim e: 3 seconds m axim um
External tem perature 0.6 tim es accuracy m axim um w ith 10C
influence: from reference tem perature
External field influence: 2.0 tim es accuracy m axim um w ith 0.5m T field
A cceptable input U p to 30% distortion
harm onic content:
Specifications Frequency Meters
Maximum frequency Center scale Error in
Hz Hz Hz
45-55 50 0.15
46-54 50 0.15
45-65 55 0.25
50-70 60 0.25
55-65 60 0.15
56-64 60 0.15
58-62 60 0.08
350-450 400 1.30
360-440 400 1.25
380-420 400 0.80
Specifications General
M anufactured in accordance w ith A m erican N ational Standards A N SI C 39.1, (1981)
33
Product Codes Transformer Rated 40/70Hz - Burden 0.3VA***
Product Code AC Overload Ammeters - True RMS Reading***
Self Contained 40/70Hz (Accuracy 1%)
Product Codes Self Contained 40/70Hz (Accuracy 1%, 60Hz)***
Moving Iron AC Ammeters
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
1A 0-1A /+ 077-08A A -LA LA -C 6 078-08A J-LA LA -C 6 079-08A A -LA LA -C 6
1.5A 0-1.5A /+ 077-08A A -LC LC -C 6 078-08A J-LC LC -C 6 079-08A A -LC LC -C 6
2A 0-2A /+ 077-08A A -LELE-C 6 078-08A J-LELE-C 6 079-08A A -LELE-C 6
3A 0-3A /+ 077-08A A -LJLJ-C 6 078-08A J-LJLJ-C 6 079-08A A -LJLJ-C 6
5A 0-5A /+ 077-08A A -LSLS-C 6 078-08A J-LSLS-C 6 079-08A A -LSLS-C 6
7.5A 0-7.5A /+ 077-08A A -M FM F-C 6 078-08A J-M FM F-C 6 079-08A A -M FM F-C 6
10A 0-10A /+ 077-08A A -M TM T-C 6 078-08A J-M TM T-C 6 079-08A A -M TM T-C 6
15A 0-15A /+ 077-08A A -N D N D -C 6 078-08A J-N D N D -C 6 079-08A A -N D N D -C 6
20A 0-20A /+ 077-08A A -N G N G -C 6 078-08A J-N G N G -C 6 079-08A A -N G N G -C 6
30A 0-30A /+ 077-08A A -N LN L-C 6 078-08A J-N LN L-C 6 079-08A A -N LN L-C 6
5A 0-10A /+ 077-08A A -LSM T-C 6 078-08A J-LSM T-C 6 079-08A A -LSM T-C 6
5A 0-15A /+ 077-08A A -LSN D -C 6 078-08A J-LSN D -C 6 079-08A A -LSN D -C 6
5A 0-20A /+ 077-08A A -LSN G -C 6 078-08A J-LSN G -C 6 079-08A A -LSN G -C 6
5A 0-25A /+ 077-08A A -LSN J-C 6 078-08A J-LSN J-C 6 079-08A A -LSN J-C 6
5A 0-30A /+ 077-08A A -LSN L-C 6 078-08A J-LSN L-C 6 079-08A A -LSN L-C 6
5A 0-40A /+ 077-08A A -LSN P-C 6 078-08A J-LSN P-C 6 079-08A A -LSN P-C 6
5A 0-50A /+ 077-08A A -LSN T-C 6 078-08A J-LSN T-C 6 079-08A A -LSN T-C 6
5A 0-75A /+ 077-08A A -LSPB -C 6 078-08A J-LSPB -C 6 079-08A A -LSPB -C 6
5A 0-100A /+ 077-08A A -LSPK-C 6 078-08A J-LSPK-C 6 079-08A A -LSPK-C 6
5A 0-150A /+ 077-08A A -LSPZ-C 6 078-08A J-LSPZ-C 6 079-08A A -LSPZ-C 6
5A 0-200A /+ 077-08A A -LSR L-C 6 078-08A J-LSR L-C 6 079-08A A -LSR L-C 6
5A 0-250A /+ 077-08A A -LSR S-C 6 078-08A J-LSR S-C 6 079-08A A -LSR S-C 6
5A 0-300A /+ 077-08A A -LSR X-C 6 078-08A J-LSR X-C 6 079-08A A -LSR X-C 6
5A 0-400A /+ 077-08A A -LSSC -C 6 078-08A J-LSSC -C 6 079-08A A -LSSC -C 6
5A 0-500A /+ 077-08A A -LSSF-C 6 078-08A J-LSSF-C 6 079-08A A -LSSF-C 6
5A 0-600A /+ 077-08A A -LSSJ-C 6 078-08A J-LSSJ-C 6 079-08A A -LSSJ-C 6
5A 0-800A /+ 077-08A A -LSSN -C 6 078-08A J-LSSN -C 6 079-08A A -LSSN -C 6
5A 0-1000A /+ 077-08A A -LSSS-C 6 078-08A J-LSSS-C 6 079-08A A -LSSS-C 6
5A 0-1200A /+ 077-08A A -LSSU -C 6 078-08A J-LSSU -C 6 079-08A A -LSSU -C 6
5A 0-1500A /+ 077-08A A -LSTC -C 6 078-08A J-LSTC -C 6 079-08A A -LSTC -C 6
5A 0-1600A /+ 077-08A A -LSTE-C 6 078-08A J-LSTE-C 6 079-08A A -LSTE-C 6
5A 0-2000A /+ 077-08A A -LSTM -C 6 078-08A J-LSTM -C 6 079-08A A -LSTM -C 6
5A 0-2500A /+ 077-08A A -LSTU -C 6 078-08A J-LSTU -C 6 079-08A A -LSTU -C 6
5A 0-3000A /+ 077-08A A -LSU A -C 6 078-08A J-LSU A -C 6 079-08A A -LSU A -C 6
5A 0-4000A /+ 077-08A A -LSU E-C 6 078-08A J-LSU E-C 6 079-08A A -LSU E-C 6
5A 0-5000A /+ 077-08A A -LSU J-C 6 078-08A J-LSU J-C 6 079-08A A -LSU J-C 6
5A 0-6000A /+ 077-08A A -LSU P-C 6 078-08A J-LSU P-C 6 079-08A A -LSU P-C 6
5A 0-7000A /+ 077-08A A -LSU S-C 6 078-08A J-LSU S-C 6 079-08A A -LSU S-C 6
5A 0-8000A /+ 077-08A A -LSU W -C 6 078-08A J-LSU W -C 6 079-08A A -LSU W -C 6
5/30A To suit 077-086A -LS**-C 6 078-086J-LS**-C 6 079-086A -LS**-C 6
R ated 5A for standard C Ts w ith 6 x full scale. * O ther scales are available
O verload portion of the scale is not subject to ** Specify scale required
the accuracy guarantee. *** For case types 077/078/079 use
U L approved file no. E203000 10-32 U N F term inals. For M 5 screw
clam p term inals, use case type 075
077 m oving iron am m eters available as listed above.
AC Overload Ammeters
34
Product Codes Self Contained 60Hz 20% (Accuracy 1%)***
Moving Iron AC Voltmeters
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
150V 0-150V /+ 077-08VA -PZPZ-C 6 078-08VJ-PZPZ-C 6 079-08VA -PZPZ-C 6
250V 0-250V /+ 077-08VA -R SR S-C 6 078-08VJ-R SR S-C 6 079-08VA -R SR S-C 6
300V 0-300V /+ 077-08VA -R XR X-C 6 078-08VJ-R XR X-C 6 079-08VA -R XR X-C 6
500V 0-500V /+ 077-08VA -SFSF-C 6 078-08VJ-SFSF-C 6 079-08VA -SFSF-C 6
600V 0-600V /+ 077-08VA -SJSJ-C 6 078-08VJ-SJSJ-C 6 079-08VA -SJSJ-C 6
750V 0-750V 077-08VA -SM SM -C 6 078-08VJ-SM SM -C 6 079-08VA -SM SM -C 6
Product Codes Transformer Rated 50/60HZ (Accuracy 1%)
0.8VA @150V***
150V 0-300V /+ 077-08VA -PZR X-C 6 078-08VJ-PZR X-C 6 079-08VA -PZR X-C 6
150V 0-600V /+ 077-08VA -PZSJ-C 6 078-08VJ-PZSJ-C 6 079-08VA -PZSJ-C 6
150V 0-750V /+ 077-08VA -PZSM -C 6 078-08VJ-PZSM -C 6 079-08VA -PZSM -C 6
150V 0-3000V /+ 077-08VA -PZU A -C 6 078-08VJ-PZU A -C 6 079-08VA -PZU A -C 6
150V 0-5250V /+ 077-08VA -PZU L-C 6 078-08VJ-PZU L-C 6 079-08VA -PZU L-C 6
150V 0-6000V /+ 077-08VA -PZU P-C 6 078-08VJ-PZU P-C 6 079-08VA -PZU P-C 6
150V 0-9000V /+ 077-08VA -PZU Y-C 6 078-08VJ-PZU Y-C 6 079-08VA -PZU Y-C 6
150V 0-15KV /+ 077-08VA -PZW C -C 6 078-08VJ-PZW C -C 6 079-08VA -PZW C -C 6
150V 0-18KV /+ 077-08VA -PZW D -C 6 078-08VJ-PZW D -C 6 079-08VA -PZW D -C 6
150V 0-45KV /+ 077-08VA -PZW J-C 6 078-08VJ-PZW J-C 6 079-08VA -PZW J-C 6
250V 0-600V /+ 077-08VA -R SSJ-C 6 078-08VJ-R SSJ-C 6 079-08VA -R SSJ-C 6
U L approved file no. E203000 * O ther scales are available
*** For case types 077/078/079 use
10-32 U N F term inals. For M 5 screw
clam p term inals, use case type 075
AC Voltmeter
35
Product Codes Self Contained 40/70Hz (Accuracy 1%, 60Hz)***
RMS Reading AC Ammeters
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
1A 0-1A /+ 077-05FA -LA LA -C 6 078-05FJ-LA LA -C 6 079-05FA -LA LA -C 6
1.5A 0-1.5A /+ 077-05FA -LC LC -C 6 078-05FJ-LC LC -C 6 079-05FA -LC LC -C 6
2A 0-2A /+ 077-05FA -LELE-C 6 078-05FJ-LELE-C 6 079-05FA -LELE-C 6
3A 0-3A /+ 077-05FA -LJLJ-C 6 078-05FJ-LJLJ-C 6 079-05FA -LJLJ-C 6
5A 0-5A /+ 077-05FA -LSLS-C 6 078-05FJ-LSLS-C 6 079-05FA -LSLS-C 6
7.5A 0-7.5A /+ 077-05FA -M FM F-C 6 078-05FJ-M FM F-C 6 079-05FA -M FM F-C 6
10A 0-10A /+ 077-05FA -M TM T-C 6 078-05FJ-M TM T-C 6 079-05FA -M TM T-C 6
15A 0-15A /+ 077-05FA -N D N D -C 6 078-05FJ-N D N D -C 6 079-05FA -N D N D -C 6
20A 0-20A /+ 077-05FA -N G N G -C 6 078-05FJ-N G N G -C 6 079-05FA -N G N G -C 6
30A 0-30A /+ 077-05FA -N LN L-C 6 078-05FJ-N LN L-C 6 079-05FA -N LN L-C 6
Product Codes Transformer Rated 40/70Hz - Burden 0.3VA***
150V 0-300V /+ 077-08VA -PZR X-C 6 078-08VJ-PZR X-C 6 079-08VA -PZR X-C 6
5A 0-10A /+ 077-05FA -LSM T-C 6 078-05FJ-LSM T-C 6 079-05FA -LSM T-C 6
5A 0-15A /+ 077-05FA -LSN D -C 6 078-05FJ-LSN D -C 6 079-05FA -LSN D -C 6
5A 0-20A /+ 077-05FA -LSN G -C 6 078-05FJ-LSN G -C 6 079-05FA -LSN G -C 6
5A 0-25A /+ 077-05FA -LSN J-C 6 078-05FJ-LSN J-C 6 079-05FA -LSN J-C 6
5A 0-30A /+ 077-05FA -LSN L-C 6 078-05FJ-LSN L-C 6 079-05FA -LSN L-C 6
5A 0-40A /+ 077-05FA -LSN P-C 6 078-05FJ-LSN P-C 6 079-05FA -LSN P-C 6
5A 0-50A /+ 077-05FA -LSN T-C 6 078-05FJ-LSN T-C 6 079-05FA -LSN T-C 6
5A 0-75A /+ 077-05FA -LSPB -C 6 078-05FJ-LSPB -C 6 079-05FA -LSPB -C 6
5A 0-100A /+ 077-05FA -LSPK-C 6 078-05FJ-LSPK-C 6 079-05FA -LSPK-C 6
5A 0-150A /+ 077-05FA -LSPZ-C 6 078-05FJ-LSPZ-C 6 079-05FA -LSPZ-C 6
5A 0-200A /+ 077-05FA -LSR L-C 6 078-05FJ-LSR L-C 6 079-05FA -LSR L-C 6
5A 0-250A /+ 077-05FA -LSR S-C 6 078-05FJ-LSR S-C 6 079-05FA -LSR S-C 6
5A 0-300A /+ 077-05FA -LSR X-C 6 078-05FJ-LSR X-C 6 079-05FA -LSR X-C 6
5A 0-400A /+ 077-05FA -LSSC -C 6 078-05FJ-LSSC -C 6 079-05FA -LSSC -C 6
5A 0-500A /+ 077-05FA -LSSF-C 6 078-05FJ-LSSF-C 6 079-05FA -LSSF-C 6
5A 0-600A /+ 077-05FA -LSSJ-C 6 078-05FJ-LSSJ-C 6 079-05FA -LSSJ-C 6
5A 0-800A /+ 077-05FA -LSSN -C 6 078-05FJ-LSSN -C 6 079-05FA -LSSN -C 6
5A 0-1000A /+ 077-05FA -LSSS-C 6 078-05FJ-LSSS-C 6 079-05FA -LSSS-C 6
5A 0-1200A /+ 077-05FA -LSSU -C 6 078-05FJ-LSSU -C 6 079-05FA -LSSU -C 6
5A 0-1500A /+ 077-05FA -LSTC -C 6 078-05FJ-LSTC -C 6 079-05FA -LSTC -C 6
5A 0-1600A /+ 077-05FA -LSTE-C 6 078-05FJ-LSTE-C 6 079-05FA -LSTE-C 6
5A 0-2000A /+ 077-05FA -LSTM -C 6 078-05FJ-LSTM -C 6 079-05FA -LSTM -C 6
5A 0-2500A /+ 077-05FA -LSTU -C 6 078-05FJ-LSTU -C 6 079-05FA -LSTU -C 6
5A 0-3000A /+ 077-05FA -LSU A -C 6 078-05FJ-LSU A -C 6 079-05FA -LSU A -C 6
5A 0-4000A /+ 077-05FA -LSU E-C 6 078-05FJ-LSU E-C 6 079-05FA -LSU E-C 6
5A 0-5000A /+ 077-05FA -LSU J-C 6 078-05FJ-LSU J-C 6 079-05FA -LSU J-C 6
5A 0-6000A /+ 077-05FA -LSU P-C 6 078-05FJ-LSU P-C 6 079-05FA -LSU P-C 6
5A 0-7000A /+ 077-05FA -LSU S-C 6 078-05FJ-LSU S-C 6 079-05FA -LSU S-C 6
5A 0-8000A /+ 077-05FA -LSU W -C 6 078-05FJ-LSU W -C 6 079-05FA -LSU W -C 6
R ated 5A for standard C Ts w ith 6 x full scale. * O ther scales are available
O verload portion of the scale is not subject ** Specify scale required
to the accuracy guarantee. *** For case types 077/078/079 use
U L approved file no. E203000 10-32 U N F term inals. For M 5 screw
clam p term inals, use case type 075
AC Ammeter
For A C rectified non-R M S com pensated m eter, please replace the -05F in the product
code w ith -05B .
For A C rectified non-R M S com pensated m eter, please replace the -05F in the product
code w ith -05B .
36
AC Voltmeter
AC Voltmeter Expanded Scale
Product Codes Self Contained 60Hz 20% (Accuracy 1%)***
RMS Reading AC Voltmeters
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
150V 0-150V /+ 077-05G A -PZPZ-C 6 078-05G J-PZPZ-C 6 079-05G A -PZPZ-C 6
250V 0-250V /+ 077-05G A -R SR S-C 6 078-05G J-R SR S-C 6 079-05G A -R SR S-C 6
300V 0-300V /+ 077-05G A -R XR X-C 6 078-05G J-R XR X-C 6 079-05G A -R XR X-C 6
500V 0-500V /+ 077-05G A -SFSF-C 6 078-05G J-SFSF-C 6 079-05G A -SFSF-C 6
600V 0-600V /+ 077-05G A -SJSJ-C 6 078-05G J-SJSJ-C 6 079-05G A -SJSJ-C 6
750V 0-750V 077-05G A -SM SM -C 6 078-05G J-SM SM -C 6 079-05G A -SM SM -C 6
For A C rectified non-R M S com pensated m eter, please replace the -05G in the
productcode w ith -05W .
Product Codes Transformer Rated 50/60HZ (Accuracy 1%)
0.8VA @150V***
150V 0-300V /+ 077-05G A -PZR X-C 6 078-05G J-PZR X-C 6 079-05G A -PZR X-C 6
150V 0-600V /+ 077-05G A -PZSJ-C 6 078-05G J-PZSJ-C 6 079-05G A -PZSJ-C 6
150V 0-750V /+ 077-05G A -PZSM -C 6 078-05G J-PZSM -C 6 079-05G A -PZSM -C 6
150V 0-3000V /+ 077-05G A -PZU A -C 6 078-05G J-PZU A -C 6 079-05G A -PZU A -C 6
150V 0-5250V /+ 077-05G A -PZU L-C 6 078-05G J-PZU L-C 6 079-05G A -PZU L-C 6
150V 0-6000V /+ 077-05G A -PZU P-C 6 078-05G J-PZU P-C 6 079-05G A -PZU P-C 6
150V 0-9000V /+ 077-05G A -PZU Y-C 6 078-05G J-PZU Y-C 6 079-05G A -PZU Y-C 6
150V 0-15KV /+ 077-05G A -PZW C -C 6 078-05G J-PZW C -C 6 079-05G A -PZW C -C 6
150V 0-18KV /+ 077-05G A -PZW D -C 6 078-05G J-PZW D -C 6 079-05G A -PZW D -C 6
150V 0-45KV /+ 077-05G A -PZW J-C 6 078-05G J-PZW J-C 6 079-05G A -PZW J-C 6
250V 0-600V /+ 077-05G A -R SSJ-C 6 078-05G J-R SSJ-C 6 079-05G A -R SSJ-C 6
For A C rectified non-R M S com pensated m eter, please replace the -05G in the product
code w ith -05W .
077 m oving iron am m eters and voltm eters available as listed above.
Product Codes Expanded Scale - Moving Coil Zener Diode***
(Accuracy 0.3% of Mid-scale Value) Self Contained, 20-1000Hz
110-130V 110-130V 077-05YA -PN PN -C 6 078-05YJ-PN PN -C 6 079-05YA -PN PN -C 6
110-130V To suit PT 077-05YA -PN **-C 6 078-05YJ-PN **-C 6 079-05YA -PN **-C 6
Product Codes Instantaneous AC Voltmeter***
with Instantaneous Maximum Reading Slave Pointer
150V To suit PT 077-05XA -PZ**-C 6
250V To suit PT 077-05XA -R S**-C 6
300V To suit PT 077-05XA -R X**-C 6
U L approved file no. E203000 * O ther scales are available
** Specify scale required
*** For case types 077/078/079 use 10-32
U N F term inals. For M 5 screw clam p
term inals, use case type 075
37
DC Ammeter
Product Codes Self Contained (Accuracy 1%)****
DC Ammeters
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
0-200A 0-200A /+ 077-05A A -EA EA 078-05A J-EA EA 079-05A A -EA EA
0-300A 0-300A /+ 077-05A A -EEEE 078-05A J-EEEE 079-05A A -EEEE
0-500A 0-500A /+ 077-05A A -EM EM 078-05A J-EM EM 079-05A A -EM EM
0-800A 0-800A /+ 077-05A A -EW EW 078-05A J-EW EW 079-05A A -EW EW
0-1m A 0-1m A /+ 077-05A A -FA FA 078-05A J-FA FA 079-05A A -FA FA
0-2m A 0-2m A /+ 077-05A A -FG FG 078-05A J-FG FG 079-05A A -FG FG
0-5m A 0-5m A /+ 077-05A A -FXFX 078-05A J-FXFX 079-05A A -FXFX
0-10m A 0-10m A /+ 077-05A A -H A H A 078-05A J-H A H A 079-05A A -H A H A
0-20m A 0-20m A /+ 077-05A A -H FH F 078-05A J-H FH F 079-05A A -H FH F
0-30m A 0-30m A /+ 077-05A A -H M H M 078-05A J-H M H M 079-05A A -H M H M
0-50m A 0-50m A /+ 077-05A A -H XH Y 078-05A J-H XH Y 079-05A A -H XH Y
0-100m A 0-100m A /+ 077-05A A -JR JR 078-05A J-JR JR 079-05A A -JR JR
0-200m A 0-200m A /+ 077-05A A -KA KA 078-05A J-KA KA 079-05A A -KA KA
0-300m A 0-300m A /+ 077-05A A -KG KG 078-05A J-KG KG 079-05A A -KG KG
0-500m A 0-500m A /+ 077-05A A -KM KM 078-05A J-KM KM 079-05A A -KM KM
0-800m A 0-800m A /+ 077-05A A -KW KW 078-05A J-KW KW 079-05A A -KW KW
0-1A 0-1A /+ 077-05A A -LA LA 078-05A J-LA LA 079-05A A -LA LA
0-5A 0-5A /+ 077-05A A -LSLS 078-05A J-LSLS 079-05A A -LSLS
0-10A 0-10A /+ 077-05A A -M TM T 078-05A J-M TM T 079-05A A -M TM T
0-15A 0-15A /+ 077-05A A -N D N D 078-05A J-N D N D 079-05A A -N D N D
0-20A 0-20A /+ 077-05A A -N G N G 078-05A J-N G N G 079-05A A -N G N G
0-30A 0-30A /+ 077-05A A -N LN L 078-05A J-N LN L 079-05A A -N LN L
Intrinsically safe milliammeters
(accuracy 1%)
ISSEP certified
Rating Standard case
catalogue no.
1m A D C 077-11A F-FA **
5m A D C 077-11A F-FX**
10m A D C 077-11A F-H A **
20m A D C 077-11A F-H F**
4/20m A D C 077-11R FH G **
** State scale m arking as required
Product Codes Milliammeters - Suppressed Zero,
No Zero Set Unless Specified****
1/5m A To Suit /+ 077-05R A -G M ** 078-05R J-G M ** 079-05R A -G M **
4/20m A To Suit /+ 077-05R A -H G ** 078-05R J-H G ** 079-05R A -H G **
10/50m A To Suit /+ 077-05R A -H Z** 078-05R J-H Z** 079-05R A -H Z**
Product Codes Shunt Rated (Accuracy 1%)****
50m V (4m A ) To suit /+ 077-05A A -EY** 078-05A J-EY** 079-05A A -EY**
50-0-50m V shunt /+ 077-05C A -G B ** 078-05C J-G B ** 079-05C A -G B **
100m V (4m A ) rating /+ 077-05A A -G B ** 078-05A J-G B ** 079-05A A -G B **
100-0-100m V /+ 077-05C A -G M ** 078-05C J-G M ** 079-05C A -G M **
Product Codes Zero Left For Use With 50mV Shunts and
0.05 Ohm Shunt Leads*** and ****
50m V 0-15A /+ 077-05A A -EYN D 078-05A J-EYN D 079-05A A -EYN D
50m V 0-20A /+ 077-05A A -EYN G 078-05A J-EYN G 079-05A A -EYN G
50m V 0-30A /+ 077-05A A -EYN L 078-05A J-EYN L 079-05A A -EYN L
50m V 0-40A /+ 077-05A A -EYN P 078-05A J-EYN P 079-05A A -EYN P
50m V 0-75A /+ 077-05A A -EYPB 078-05A J-EYPB 079-05A A -EYPB
50m V 0-100A /+ 077-05A A -EYPK 078-05A J-EYPK 079-05A A -EYPK
50m V 0-150A /+ 077-05A A -EYPZ 078-05A J-EYPZ 079-05A A -EYPZ
50m V 0-200A /+ 077-05A A -EYR L 078-05A J-EYR L 079-05A A -EYR L
50m V 0-300A /+ 077-05A A -EYR X 078-05A J-EYR X 079-05A A -EYR X
50m V 0-400A /+ 077-05A A -EYSC 078-05A J-EYSC 079-05A A -EYSC
50m V 0-500A /+ 077-05A A -EYSF 078-05A J-EYSF 079-05A A -EYSF
50m V 0-750A /+ 077-05A A -EYSM 078-05A J-EYSM 079-05A A -EYSM
50m V 0-1000A /+ 077-05A A -EYSS 078-05A J-EYSS 079-05A A -EYSS
50m V 0-1200A /+ 077-05A A -EYSU 078-05A J-EYSU 079-05A A -EYSU
50m V 0-1500A /+ 077-05A A -EYTC 078-05A J-EYTC 079-05A A -EYTC
50m V 0-2000A /+ 077-05A A -EYTM 078-05A J-EYTM 079-05A A -EYTM
50m V 0-3000A /+ 077-05A A -EYU A 078-05A J-EYU A 079-05A A -EYU A
U L approved file no. E203000
Specify shunt lead resistance value
if in excess of 0.05 ohm s for
calibration purposes.
D C shunt rated am m eters have
therm istor circuit am bient
tem perature com pensation.
Separate shunt and shunt leads are
not included.
* O ther scales are available
** Specify scale required.
*** O ther m V ratings and scale
options available upon
request.
**** For case types 077/078/079
use 10-32 U N F term inals.
For M 5 screw clam p
term inals, use case type 075.
To suit
shunt
rating
38
Product Codes Sensitivity 1000 Ohms / Volt (Accuracy 1%)***
DC Voltmeters
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
50m V-800V To suit /+ 077-05VA -** 078-05VJ-** 079-05VA -**
0-15V 0-15V /+ 077-05VA -N D N D 078-05VJ-N D N D 079-05VA -N D N D
0-30V 0-30V /+ 077-05VA -N LN L 078-05VJ-N LN L 079-05VA -N LN L
0-50V 0-50V /+ 077-05VA -N TN T 078-05VJ-N TN T 079-05VA -N TN T
0-75V 0-75V /+ 077-05VA -PB PB 078-05VJ-PB PB 079-05VA -PB PB
0-150V 0-150V /+ 077-05VA -PZPZ 078-05VJ-PZPZ 079-05VA -PZPZ
0-300V 0-300V /+ 077-05VA -R XR X 078-05VJ-R XR X 079-05VA -R XR X
0-400V 0-400V /+ 077-05VA -SC SC 078-05VJ-SC SC 079-05VA -SC SC
0-500V 0-500V /+ 077-05VA -SFSF 078-05VJ-SFSF 079-05VA -SFSF
0-600V 0-600V /+ 077-05VA -SJSJ 078-05VJ-SJSJ 079-05VA -SJSJ
0-750V 0-750V 077-05VA -SM SM 078-05VJ-SM SM 079-05VA -SM SM
0-800V 0-800V 077-05VA -SN SN 078-05VJ-SN SN 079-05VA -SN SN
Product Codes 120V Self Contained***
Frequency Meters
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
50H z+ /-0.15 45-55H z /+ 077-41LA -PN A G -A G 078-41LJ-PN A G -A G 079-41LA -PN A G -A G
50H z+ /-0.15 46-54H z /+ 077-41LA -PN A H -A H 078-41LJ-PN A H -A H 079-41LA -PN A H -A H
50H z+ /-0.25 45-65H z /+ 077-41LA -PN A J-A J 078-41LJ-PN A J-A J 079-41LA -PN A J-A J
60H z+ /-0.25 50-70H z /+ 077-41LA -PN A L-A L 078-41LJ-PN A L-A L 079-41LA -PN A L-A L
60H z+ /-0.15 55-65H z /+ 077-41LA -PN A N -A N 078-41LJ-PN A N -A N 079-41LA -PN A N -A N
60H z+ /-0.15 56-64H z /+ 077-41LA -PN A O -A O 078-41LJ-PN A O -A O 079-41LA -PN A O -A O
60H z+ /-0.08 58-62H z /+ 077-41LA -PN A T-A G 078-41LJ-PN A G -A G 079-41LA -PN A G -A G
400H z+ /-1.3 350-450H z /+ 077-41LA -PN B H -B H 078-41LJ-PN B H -B H 079-41LA -PN B H -B H
400H z+ /-1.25 360-440H z /+ 077-41LA -PN B I-B I 078-41LJ-PN B I-B I 079-41LA -PN B I-B I
400H z+ /- 0.8 380-420H z /+ 077-41LA -PN B K-B K 078-41LJ-PN B K-B K 079-41LA -PN B K-B K
Product Codes Zero Centre - Sensitivity 2000 Ohms /
Volt (Accuracy 1%)***
150-0-150V 150-0-150V /+ 077-05N A -R XR X 078-05N J-R XR X 079-05N A -R XR X
300-0-300V 300-0-300V /+ 077-05N A -SJSJ 078-05N J-SJSJ 079-05N A -SJSJ
500-0-500V 500-0-500V /+ 077-05N A -SSSS 078-05N J-SSSS 079-05N A -SSSS
600-0-600V 600-0-600V /+ 077-05N A -SU SU 078-05N J-SU SU 079-05N A -SU SU
Product Codes Suppressed Zero***
1 - 5V To suit /+ 077-05S-LM 078-05S-LM 079-05S-LM
For alternative voltage rating 200-250V, * O ther scales are available
use code R N instead of PN ** Specify scale required
For alternative voltage rating 380-480V, ***For case types 077/078/079 use
use code SE instead of PN 10-32 U N F term inals. For M 5 screw
U L approved file no. E203000 clam p term inals, use case type 075
DC Voltmeter
Frequency Meter
39
** Specify scale required
U L approved
AC Maximum Demand Ammeter
Thermal Instantaneous
Maximum Demand Ammeter
Instantaneous Maximum
Demand Ammeter
Thermal Maximum Demand Directly Heated Element Type
M eter indicates the m axim um average am pere dem and of a system .
A red resettable slave pointer is driven upscale by the indicating pointer
to show m axim um average current value since the previous setting.
4
1
/2" square flange.
Product Codes
B urden: 3.5VA w ith lim iting C T, 2.5VA w ithout lim iting C T
Tim e lag: 15 m inutes
A ccuracy: 3% , 50 or 60H z
5/6A w ith 20% overload and internal lim iting C T C T 077-16EU -LS**
5A - w ithout overload, w ith internal lim iting C T 077-16EU -LS**- N O
Thermal / Instantaneous Maximum Demand Ammeter (MDA)
A llow s instantaneous current values to be read independently of the
therm al indicator. This m eter com bines a therm al m ovem ent w ith a
rugged short-scale iron vane indicator.
Instantaneous Maximum Demand Ammeter with
SlavePointer
D esigned for com patibility w ith other 4
1
2" sw itchboard m eters, this
instrum ent enhances panel appearance and indicates m axim um
instantaneous load current values. A long-scale high torque, taut band
iron vane m ovem ent drives the red slave pointer.
Product Codes
B urden: 4VA w ith lim iting C T, 3VA w ithout lim iting C T
Tim e lag: 15 m inutes
A ccuracy: 3% M D A , 2% iron vane, 50 or 60H z
B urden: 5VA
A ccuracy: 1% 50 or 60H z
Thermal / instantaneous MDA
5/6A w ith 20% overload scale and internal lim iting C T 077-16FU -LS**
5A - w ithout 20% overload scale, w ith internal lim iting C T 077-16FU -LS** - N O
Dual range - thermal instantaneous
3/6A - w ith 20% overload scale 077-16FU -LK**
2.5/5A - w ithout 20% overload scale 077-16FU -LK** - N O
6/12A w ith 20% overload scale and internal lim iting C T 077-16FU -LV**
5/10A - w ithout 20% overload scale w ith internal lim iting C T 077-16FU -LV** - N O
Product Code
5A - w ithout overload scale 077-08D A -LS**
Specifications
Specifications
Specifications
40
AC Wattmeters and VArmeters
The C rom pton 70 series of A C w attm eters and VA rm eters incorporate a
D C m oving coil taut band indicator w ith the C rom pton designed m icro-
circuit w att transducer PC B to read pow er on single or three-phase
system s. VA rm eters can be supplied w ith internal or external phase
shifter according to user preferences. The m ost frequently selected
w attm eter scale m arking for com m on current and voltage transform ers
are listed on the follow ing pages. In addition, these instrum ents m ay be
supplied w ith zero-left or center-zero scales at the sam e list price.
Scaling
W attm eter and VA rm eter current circuits should have equal carrying capacity because
they are frequently connected in series. This m eans that the sum of the left and right
end-scale values of the VA rm eters should be equal to or greater than the full scale value
of the w attm eter (or have higher end-scale values if the instrum ents are center or
offset-zero). Instrum ents m easuring 10,000 kilow atts and over are m arked in
m egaw atts. C enter-zero or offset-zero w att and VA rm eters are m arked IN for left
deflection and O U Tfor right deflection. C ustom ised scales m ay be calculated for
w attm eters and VA rm eters not listed on the charts. Scales for w atts m ust be one of the
standard full-scale dial m arkings show n in the charts.
Calibration
For full load value of w atts or VA r, assum ing unity pow er factor:
1-phase 2-w ire w atts = am ps x volts
3-phase 3-w ire w atts = am ps x line-to-line volts x 3
3-phase 4-w ire w atts = am ps x line-to-neutral volts x 3
M inim um scale values are obtained by m ultiplying resultant w atts, using the above
form ula x 0.7 and selecting next higher standard scale.
For m axim um scale value, m ultiply x 1.3 and select the next low est standard.
If scale calculates to an exact listed value, use this value rather than the next higher or
low er value.
Note: W hen ordering w attm eters and VA rm eters, please specify C T ratio, VT ratio and
required scale.
B urden per elem ent: C urrent circuit: 2VA
Voltage circuit: 1VA
A ccuracy: C lass 1.0
A m bient range: 0 to + 60C , (32 to 140F) standard calibration 20C (68F)
A m bient influence: 0.05% per 1C m axim um
O verloads-current: 10 x rating for 5 seconds., 1.2 x continuously
Voltage: 2 x rating for 5 seconds., 1.2 x continuouslyVoltage
influence: A ccuracy m aintained, 80-110% rated voltage
Pow er factor influence: A ccuracy m aintained 0.1 lag to 0.1 lead
Enclosure code: 077: IP54 optional IP55
078: IP67
079: IP54 optional IP55
R esponse tim e: 077,078: approxim ately 2.5 seconds
079: approxim ately 3.5 seconds
D ielectric test: Live parts to case including panel 2600V R M S for 1 m inute
Specifications
41
Wattmeter/VArmeter Scale Selector Guide
120 208 240 480 600 2400 3600 4200 4800 6000 7200 8400
Primary potential transformer (1:1) (1.73:1) (2:1) (4:1) (5:1) (20:1) (30:1) (35:1) (40:1) (50:1) (60:1) (70:1)
voltage system
3-phase 3-wire (L-L) 120 208 240 480 600 2400 3600 4200 4800 6000 7200 8400
system voltage
3-phase 4-wire (L-N) 69 120 139 277 347 1390 2100 2400 2770 3500 4160 4800
currrent transformer
R A TIO N orm al 5KW 10KW 10KW 20KW 25KW 100KW 150KW 175KW 200KW 250KW 300KW 350KW
25/5 M ax. 6 10 12 25 30 120 200 200 250 300 400 450
(5:1) M in. 3 5 6 12.5 15 60 100 100 125 150 200 225
R A TIO N orm al 10KW 20KW 20KW 40KW 50KW 200KW 300KW 350KW 400KW 500KW 600KW 700KW
50/5 M ax. 12 20 25 50 60 250 400 450 500 600 800 900
(10:1) M in. 6 10 12.5 25 30 125 200 250 250 300 400 450
R A TIO N orm al 15KW 25KW 30KW 60KW 75KW 300KW 500KW 500KW 600KW 750KW 900KW 1000KW
75/5 M ax. 20 30 40 80 100 400 600 700 800 1000 1200 1200
(15:1) M in. 10 15 20 40 50 200 300 350 400 500 600 600
R A TIO N orm al 20KW 30KW 40KW 75KW 100KW 400KW 600KW 700KW 800KW 1000KW 1200KW 1200KW
100/5 M ax. 25 40 50 100 120 500 800 900 1000 1200 1500 1500
(20:1) M in. 12.5 20 25 50 60 250 400 450 500 600 750 750
R A TIO N orm al 30KW 50KW 50KW 100KW 150KW 600KW 800KW 1000KW 1200KW 1500KW 1800KW 2000KW
150/5 M ax. 40 70 75 150 200 800 1200 1200 1500 2000 2400 2500
(30:1) M in. 20 35 35 75 100 400 600 600 750 1000 1000 1250
R A TIO N orm al 40KW 75KW 75KW 150KW 200KW 800KW 1200KW 1200KW 1500KW 2000KW 2500KW 3000KW
200/5 M ax. 50 80 100 200 250 1000 1500 1500 2000 2500 3000 3500
(40:1) M in. 25 40 50 100 125 500 750 750 1000 1250 1500 1500
R A TIO N orm al 70KW 100KW 100KW 200KW 300KW 1200KW 1500KW 2000KW 2500KW 3000KW 3500KW 4500KW
300/5 M ax. 75 120 150 300 400 1500 2000 2500 3000 4000 4000 5000
(60:1) M in. 35 60 75 150 200 750 1000 1250 1500 2000 2000 2500
R A TIO N orm al 75KW 125KW 150KW 300KW 400KW 1500KW 2500KW 3000KW 3000KW 4000KW 5000KW 6000KW
400/5 M ax. 100 150 200 400 500 2000 3000 3600 4000 5000 6000 7000
(80:1) M in. 50 75 100 200 250 1000 1500 1500 2000 2500 3000 3500
R A TIO N orm al 125KW 200KW 200KW 450KW 600KW 2000KW 3000KW 4000KW 5000KW 6000KW 7500KW 8000KW
600/5 M ax. 150 250 300 600 800 3000 4000 5000 6000 8000 8000 10M W
(120:1) M in. 75 125 150 300 400 1500 2000 2500 3000 4000 4000 5000KW
R A TIO N orm al 150KW 250KW 300KW 600KW 800KW 3000KW 5000KW 6000KW 6000KW 8000KW 10M W 12M W
800/5 M ax. 200 350 400 800 1000 4000 6000 7500 8000 10M W 12 15
(160:1) M in. 100 175 200 400 500 2000 3000 3000 40000 5000KW 6000KW 7500KW
R A TIO N orm al 200KW 350KW 400KW 800KW 1000KW 4000KW 6000KW 6000KW 8000KW 10M W 12M W 15M W
1000/5 M ax. 250 450 500 1000 1200 5000 8000 8000 10M W 12 15 18
(200:1) M in. 125 225 250 500 600 2500 4000 4000 5000KW 6000KW 7500KW 10
R A TIO N orm al 250KW 400KW 500KW 1000KW 1200KW 5000KW 7000KW 8000KW 10M W 12M W 15M W 10M W
1200/5 M ax. 300 500 600 1200 1500 6000 8000 10M W 12 15 18 20
(240:1) M in. 150 250 300 600 750 3000 4000 5000KW 6000KW 7500KW 10 10
R A TIO N orm al 300KW 500KW 600KW 1200KW 1500KW 6000KW 10M W 10M W 12M W 15M W 20M W 20M W
1500/5 M ax. 400 700 750 1500 2000 8000 12 12 15 20 20 25
(300:1) M in. 200 350 375 1000 1000 4000 6000KW 6000KW 7500KW 10 10 12.5
R A TIO N orm al 400KW 750KW 800KW 1600KW 2000KW 8000KW 12M W 12M W 15M W 20M W 25M W 30M W
2000/5 M ax. 500 800 1000 2000 2500 10M W 15 15 20 25 30 35
(400:1) M in. 250 400 500 750 1250 5000 7500KW 7500KW 10 12.5 15 20
R A TIO N orm al 750KW 1000KW 1200KW 2000KW 3000KW 12M W 18M W 20M W 25M W 30M W 35M W 40M W
3000/5 M ax. 800 1200 1500 3000 4000 15 20 25 30 40 40 50
(600:1) M in. 400 600 750 1500 2000 7500KW 10 12.5 15 20 20 25
R A TIO N orm al 800KW 1200KW 1500KW 3000KW 4000KW 15M W 20M W 25M W 30M W 40M W 50M W 50M W
4000/5 M ax. 1000 1500 2000 4000 5000 20 30 30 40 50 60 75
(800:1) M in. 500 750 1000 2000 2500 10 15 15 20 25 30 40
R A TIO N orm al 1000KW 1500KW 2000KW 4000KW 5000KW 20M W 30M W 20M W 40M W 50M W 60M W 75M W
5000/5 M ax. 1250 2000 2500 5000 6000 25 40 25 50 60 80 80
(1000:1) M in. 500 1000 1250 2500 3000 12.5 20 12.5 25 30 40 40
R A TIO N orm al 1200KW 2000KW 2500KW 5000KW 6000KW 25M W 35M W 40M W 50M W 60M W 60M W 80M W
6000/5 M ax. 1500 2500 3000 3000 8000 30 40 50 60 80 80 100
(1200:1) M in. 750 1250 1500 1500 4000 15 20 25 30 40 40 50
42
Wattmeter/VArmeter Scale Selector Guide
12KV 14.4KV 24KV 34.5KV 38KV 46KV 92KV 115KV 138KV 345KV 765KV
Primary potential transformer (100:1) (120:1) (200:1) (300:1) (330:1) (400:1) (800:1) (1000:1) (1200:1) (3000:1) (6000:1)
voltage system
3-phase 3-wire (L-L) 12KV 14.4KV 24KV 34.5KV 38KV 46KV 92KV 115KV 138KV 345KV 765KV
system voltage
3-phase 4-wire (L-N) 6900 8300 13.8KV 20KV 22KV 26.5KV 53KV 66KV 80KV 200KV 440KV
current transformer
R A TIO N orm al 500KW 600KW 1000KW 1500KW 1500KW 1500KW 3000KW 5000KW 6000KW 15M W 30M W
25/5 M ax. 650 800 1200 1500 2000 2500 200 200 250 300 400
(5:1) M in. 325 400 600 750 1000 1250 100 100 125 150 200
R A TIO N orm al 1000KW 1200KW 2000KW 3000KW 3000KW 3500KW 8000KW 10M W 12M W 30M W 60M W
50/5 M ax. 1200 1500 2500 3500 4000 5000 10M W 12 15 35 80
(10:1) M in. 600 750 1250 1750 2000 2500 5000KW 6000KW 7500KW 15 40
R A TIO N orm al 1500KW 1800KW 3000KW 4000KW 5000KW 5000KW 10M W 15M W 15M W 45M W 100M W
75/5 M ax 2000 2000 4000 5000 6000 7500 15 15 20 50 125
(15:1) M in. 1000 1000 2000 2500 3000 3000 7500KW 7500KW 10 25 50
R A TIO N orm al 2000KW 2500KW 4000KW 6000KW 6000KW 7500KW 15M W 20M W 25M W 60M W 125M W
100/5 M ax. 2500 3000 5000 7500 8000 10M W 20 25 30 70 150
(20:1) M in. 1250 1500 2500 3000 4000 5000KW 10 12.5 15 35 75
R A TIO N orm al 3000KW 3500KW 6000KW 10M W 10M W 10M W 20M W 30M W 35M W 90M W 200M W
150/5 M ax. 4000 4000 4000 10 12 15 30 35 40 100 250
(30:1) M in. 2000 2000 2000 5000KW 6000KW 7500KW 15 15 20 50 100
R A TIO N orm al 4000KW 4500KW 8000KW 12M W 12M W 15M W 30M W 35M W 50M W 100M W 250M W
200/5 M ax. 5000 6000 5000 15 15 20 40 50 60 150 300
(40:1) M in. 2500 3000 2500 7500KW 7500KW 10 20 25 30 75 150
R A TIO N orm al 6000KW 7000KW 12M W 18M W 18M W 20M W 45M W 60M W 75M W 150M W 400M W
300/5 M ax. 8000 8000 15 20 25 30 60 75 80 200 500
(60:1) M in. 4000 4000 7.5 10 12.5 15 30 30 40 100 250
R A TIO N orm al 8000KW 10M W 15M W 24M W 25M W 30M W 60M W 80M W 100M W 200M W 500M W
400/5 M ax. 10M W 12 20 30 30 40 80 100 120 300 600
(80:1) M in. 5000KW 6000KW 10 15 15 20 40 50 60 150 300
R A TIO N orm al 12M W 15M W 25M W 35M W 40M W 45M W 90M W 100M W 150M W 350M W 800KW
600/5 M ax. 15 18 30 40 50 60 120 150 180 450 1000
(120:1) M in. 7500KW 10 15 20 25 30 60 75 75 225 500
R A TIO N orm al 15M W 20M W 30M W 50M W 50M W 60M W 120M W 150M W 200M W 500M W 1000M W
800/5 M ax. 20 25 40 60 60 80 150 200 200 600 1200
(160:1) M in. 10 12.5 20 30 30 40 75 100 100 300 600
R A TIO N orm al 20M W 25M W 40M W 50M W 60M W 75M W 150M W 200M W 250M W 600M W 1200M W
1000/5 M ax. 25 30 50 60 80 100 200 250 300 750 1500
(200:1) M in. 12.5 15 25 30 40 50 100 125 150 300 750
R A TIO N orm al 25M W 30M W 50M W 60M W 80M W 100M W 175M W 250M W 300M W 750M W 1500M W
1200/5 M ax. 30 35 60 80 100 120 200 300 350 900 2000
(240:1) M in. 15 20 30 40 50 60 100 150 175 450 1000
R A TIO N orm al 30M W 35M W 60M W 75M W 100M W 120M W 250M W 3000M W 350M W 900M W 2000M W
1500/5 M ax. 40 40 80 100 120 150 300 350 450 1000 2500
(300:1) M in. 20 20 40 50 60 75 150 175 225 500 1250
R A TIO N orm al 40M W 50M W 80M W 100M W 120M W 150M W 300M W 400M W 5000M W 1000M W 2500M W
2000/5 M ax. 50 60 100 150 150 200 400 500 600 1500 3000
(400:1) M in. 25 30 50 75 75 100 200 250 300 750 1500
R A TIO N orm al 60M W 75M W 100M W 150M W 200M W 200M W 400M W 600M W 700M W 1500M W 3500M W
3000/5 M ax. 80 80 150 200 250 300 500 750 900 2000 5000
(600:1) M in. 40 40 75 100 125 150 250 350 450 1000 2500
R A TIO N orm al 80M W 100M W 150M W 200M W 250M W 300M W 5000M W 800M W 1000M W 2000M W 500M W
4000/5 M ax. 100 125 200 300 300 400 800 1000 1200 3000 6000
(800:1) M in. 50 60 100 150 150 200 400 500 600 1500 3000
R A TIO N orm al 100M W 125M W 200M W 250M W 300M W 4000M W 750M W 1000M W 1200M W 3000M W 6000M W
5000/5 M ax. 120 150 250 300 400 500 1000 1200 1500 3500 8000
(1000:1) M in. 60 75 125 150 200 250 500 600 750 1750 400
R A TIO N orm al 120M W 150M W 250M W 350KW 400M W 450M W 1000M W 1200M W 1500M W 3500M W 8000M W
6000/5 M ax. 150 175 300 400 500 600 1200 1500 1750 4000 10000
(1200:1) M in. 75 80 150 200 250 300 600 750 800 2000 5000
43
Product Codes 1-Element, Transformer Rated. 50/60Hz.
Taut Band Integral Transducer. (Accuracy 1.0%. 50/60Hz)
AC Wattmeters
Product Codes 2-Element, Transformer Rated. 50/60Hz.
Taut Band. Integral Transducer. (Accuracy 1.0%. 50/60Hz)
AC VArmeters
AC Wattmeter
AC VArmeter
3 3 5 120V To suit /+ 077-218A -Q Q ** 078-218J-Q Q ** 079-218A -Q Q **
3 3 5 208V To suit /+ 077-218A -Q R ** 078-218J-Q R ** 079-218A -Q R **
3 3 5 240V To suit /+ 077-218A -Q S** 078-218J-Q S** 079-218A -Q S**
3 3 5 380V To suit /+ 077-218A -Q X** 078-218J-Q X** 079-218A -Q X**
3 3 5 480V To suit /+ 077-218A -Q T** 078-218J-Q T** 079-218A -Q T**
Product Codes 2-Element, Transformer Rated. 50/60Hz.
Taut Band Integral Transducer (Accuracy 1.0%. 50/60Hz)
3 4 5 69V To suit /+ 077-219A -Q L** 078-219J-Q L** 079-219A -Q L**
3 4 5 120V To suit /+ 077-219A -Q Q ** 078-219J-Q Q ** 079-219A -Q Q **
3 4 5 277V To suit 077-219A -Q Y** 078-219J-Q Y** 079-219A -Q Y**
3 4 5 346V To suit 077-219A -Q Z** 078-219J-Q Z** 079-219A -Q Z**
Product Codes 2
1
2-Element, Transformer Rated. 50/60Hz.
Taut Band Integral Transducer (Accuracy 1.0%. 50/60Hz)
Measured 4
1
2" square flange 8
3
4" square flange
system
Scales Standard case Sealed case Standard case
catalogue no. hi-shock catalogue no.
catalogue no.
P
h
a
s
e
s
W
i
r
e
s
A
m
p
e
r
e
s
1

V
A

m
a
x
.

b
u
r
d
e
n
V
o
l
t
s
1

V
A

m
a
x
.

b
u
r
d
e
n
1 2 5 120V To suit /+ 077-215A -Q Q ** 078-215J-Q Q ** 079-215A -Q Q **
1 2 5 240V To suit 077-215A -Q S** 078-215J-Q S** 079-215A -Q S**
For connection diagram , see Fig. 21 on page 60.
For connection diagram , see Fig. 25 on page 60.
3 3 5 120V To suit /+ 077-31LA -Q Q ** 078-31LJ-Q Q **
3 3 5 208V To suit /+ 077-31LA -Q R **-C 6 078-31LJ-Q R **
3 3 5 240V To suit 077-31LA -Q S** 078-31LJ-Q S**
3 3 5 380V To suit 077-31LA -Q X** 078-31LJ-Q X**
3 3 5 480V To suit 077-31LA -Q T** 078-31LJ-Q T**
For connection diagram , see Fig. 32 on page 61.
Product Codes 2
1
2-element, transformer rated. 50/60Hz.
Taut Band. Integral transducer (Accuracy 1.0%. 50/60Hz)
3 4 5 120V To suit /+ 077-31U A -Q Q ** 078-31U J-Q Q ** 079-31U A -Q Q **
3 4 5 208V To suit 077-31U A -Q R ** 078-31U J-Q R ** 079-31U A -Q R **
3 4 5 480V To suit 077-31U A -Q T** 078-31U J-Q T** 079-31U A -Q T**
U L approved file no. E203000
** Specify C T (C urrent Transform er) and VT (Voltage Transform er) ratios if used,
and preferred scale at tim e of ordering.
For connection diagram , see Fig. 32 on page 61
For connection diagram , see Fig. 28 on page 60.
3 3 120V 855-956A -PR 855-956J-PR 855-956A -PR
3 4 120V 855-957A -PR 855-957J-PR 855-957A -PR
3 4 69V 855-957A -N Z 855-957J-N Z 855-957A -N Z
Product Codes Phase Shifting Transformers
For use w ith above W attm eters, w hen VA r m easurem ent w ith external phase shifter is required.
44
Product Codes Span Accuracy of 1.0%
Self-contained for 10 ohm copper or 100 ohm platinum R TD (R esistance Tem perature
D etector) - Specify copper or platinum at tim e of ordering.
RTD Temperature Meters*
RTD Temperature Meter
4
1
2" square flange
Rating Scaling*
Standard case Sealed case hi-shock
catalogue no. catalogue no.
110/130V 20-140C 077-45R A -**Q F-PQ 078-45R J-**Q F-PQ
50/60H z
110/130V 0-150C 077-45R A -**Q E-PQ 078-45R J-**Q E-PQ
50/60H z
110/130V 0-200C 077-45R A -**Q G -PQ 078-45R J-**Q G -PQ
50/60H z
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
110/220/240V 1-18 taps 077-45P-
50/60H z
For connection diagram s, see Fig. 17 on page 59.
Product Code Span Accuracy of 1.0%
M eters are suitable for J and K type cold junction com pensation and include
therm ocouple break indication. Specify J or K type and tem perature at tim e of ordering.
Thermocouple Temperature Meters
4
1
2" square flange
Rating
standard case catalogue no.
110/130V 077-45TA -**PM
50/60H z
For connection diagram s, see Fig. 18 on page 59.
Product Code
Indicator show s transform er tap, hoist or valve position a using 3-w ire system for 1-18
tap positions w ith 400 ohm steps.
Tap Position Indicator
For connection diagram s, see Fig. 20 on page 60.
Select nearest higher rated voltm eter and specify requirem ent
U L approved file no. E203000 * O ther ranges available on request
JT for J type, KT for K type therm ocouple - C onsult w ith the factory.
** R I for 10 ohm copper or R 2 for
100ohm platinum .
*** Specify input and scale.
45
Elapsed Time Meters
Product Codes 99,999.99 hours, Non Reset. Burden 2.5VA.
50 or 60Hz
Synchronous m otor running tim e m eter w ith a non resettable indicator.
Elapsed Time Meter
AC Phase Sequence and Phase
Failure Indicator
4
1
2" square flange 8
3
4" square flange
Rating
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
110/130V 50H z 077-155A -PN ZH -C 5 078-155J-PN ZH -C 5 N ot available
200/250V 50H z 077-155A -R N ZH -C 5 078-155J-R N ZH -C 5 N ot available
480V 50H z 077-155A -SEZH -C 5 078-155J-SEZH -C 5 N ot available
110/130V 60H z 077-156A -PN ZH -C 6 078-156J-PN ZH -C 6 N ot available
200/250V 60H z 077-156A -R N ZH -C 6 078-156J-R N ZH -C 6 N ot available
480V 60H z 077-156A -SEZH -C 6 078-156J-SEZH -C 6 N ot available
12/24/40/110V D C 077-151A -
4
1
2" square flange 8
3
4" square flange
Rating
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
100/150V 50/60H z 077-12PA -P2C 6 N ot available N ot available
151/300V 50/60H z 077-12PA -P3C 6 N ot available N ot available
301/500V 50/60H z 077-12PA -P4C 6 N ot available N ot available
Product Codes Neon Bulb Tytpe. Burden 2.5VA
Tw o neon bulbs for phase sequence indication - first m arked the caption correct
1-2-3, the second m arked incorrect 3-2-1. Three neon bulbs for phase failure
indication - first m arked 1, second m arked 2, third m arked 3.
AC Phase Sequence, Phase Failure Indicators
For connection diagram s, see Fig. 1 on page 58.
4
1
2" square flange 8
3
4" square flange
Rating
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
D C Volts 077-052A -** 078-052J-*** 079-052A -***
Product Code
DC Indicators for Tachometer Generators
Select nearest higher rated voltm eter and specify requirem ent
U L approved file no. E203000 * O ther ranges available upon
JT for J type, KT for K type therm ocouple request - C onsult w ith the factory.
** R I for 10 ohm or R 2 for 100 ohm
platinum .
*** Specify input and scale
46
AC Power Factor Meter
AC Power Factor Meter
R atings, self-contained: C urrent w indings 5A .
Voltage w indings m inim um 50V, m axim um 600V
A ccuracy: B alanced Load: C lass 1, U nbalanced Load: C lass 3
O vershoot: 33%
External tem perature 0.5% fid m ax.
influence:
External field influence: 3% fid m ax.
Frequency range: 50H z or 60H z standard, 25-3000H z optional (Specify)
Frequency influence: Single phase instrum ents, 59 to 61H z 1.0% fid m ax.
Polyphase instrum ents 10% deviation from 69H z: 1.0%
O verload capacity: C urrent coils 1000% m om entarily, 100% for 15 m inutes
and 25% indefinitely.
Voltage circuits 25% indefinitely.
B urdens: Each current circuit, 1.5VA approx.
Each voltage circuit 1VA approx.
M easuring system s 077-427 - 3- or 4-w ire
R anges available: Lag 0.5-1 - 0.5 lead pow er factor
Lag 0.2-1 - 0.8 lead pow er factor
JIS dim ension product available on request.
Product Codes Balanced Load (Accuracy 1%)
Product Codes Unbalanced Load (Accuracy 3% of scale)
Measured 4
1
2" square flange 8
3
4" square flange
system
Scales Standard case Sealed case Standard case
catalogue no. hi-shock catalogue no.
catalogue no.
P
h
a
s
e
s
W
i
r
e
s
A
m
p
e
r
e
s
2

V
A

m
a
x
.

b
u
r
d
e
n
V
o
l
t
s
1

V
A

m
a
x
.

b
u
r
d
e
n
1 2 5 120V 0.5-1-0.5 /+ 077-425A -Q Q A D 078-425J-Q Q A D 079-425A -Q Q A D
1 2 5 240V 0.5-1-0.5 /+ 077-425A -Q SA D 078-427J-Q SA D 079-427A -Q SA D
3 34 5 120V 0.5-1-0.5 /+ 077-427A -Q Q A D 078-427J-Q Q A D 079-427A -Q A A D
3 34 5 208V 0.5-1-0.5 /+ 077-427A -Q R A D 078-427J-Q R A D 079-427A -Q R A D
3 34 5 240V 0.5-1-0.5 /+ 077-427A -Q SA D 078-427J-Q SA D 079-427A -Q SA D
3 34 5 480V 0.5-1-0.5 077-427A -Q TA D 078-427J-Q TA D 079-427A -Q TA D
Instrum ents m ay be used on loads dow n to 20% of current and betw een 90% and
110% of voltage rating.
For connection diagram s, see Fig. 13 and 15 on page 59.
Measured 4
1
2" square flange 8
3
4" square flange
system
Scales Standard case Sealed case Standard case
catalogue no. hi-shock catalogue no.
catalogue no.
P
h
a
s
e
s
W
i
r
e
s
A
m
p
e
r
e
s
2

V
A

m
a
x
.

b
u
r
d
e
n
V
o
l
t
s
1

V
A

m
a
x
.

b
u
r
d
e
n
3 3 5 120V 0.5-1-0.5 077-TFU A -Q Q A D
3 3 5 240V 0.5-1-0.5 077-TFU A -Q SA D
Instrum ents m ay be used on loads betw een 50% and 110% of rated current and
betw een 80% and 110% rated voltage.
For connection diagram , see Fig. 12 on page 59.
Specifications
U L approved file no. E203000
47
360 Power Factor Meter
360 Power Factor
R atings, self-contained: C urrent w indings m inim um , 0.5A , m axim um
20A . Voltage w indings m in. 50-240V, for higher
voltages of up to 480V an external box is
supplied.
N orm al operating position: O n vertical panels unless otherw ise specified at the
tim e of order.
Position influence: N ot m ore than 1% of scale length for up to 60 tilt
from norm al operating position.
A ccuracy: C lass 1.0
O vershoot: 33%
External tem p. influence: 0.5% fid. m ax.
External field influence: 3% fid. m ax
Frequency influence: Single phase instrum ents from 59-61H z 1% m ax.
fid. m ax. Polyphase instrum ent 10% deviation from
60H z: 1% fid. m ax.
O verload capacity: C urrent coils 1000% m om entarily, 100% for 15 m inutes,
and 50% indefinitely.
Voltage circuits 50% indefinitely.
Characteristics 077-132 077-136
A V A V
Im pedance ohm s: 0.162 3380 0.043 3380
R esistance ohm s: 0.147 3300 0.04 3300
R esistance ohm s: 0.082 750 0.016 750
W atts: 3.5 1.39 1.0 1.30
Volt-am peres: 4.05 1.42 1.07 1.42
R eactive (VA r): 2.03 0.281 0.4 0.281
Pow er factor: 0.86 0.96 0.93 0.98
3 34 5 120V 0-1-0 077-136A -Q Q A B 078-136J-Q Q A B 079-136A -Q Q A B
3 34 5 208V 0-1-0 077-136A -Q R A B 078-136J-Q R A B 079-136A -Q R A B
3 3 5 120V 0-1-0 077-132A -Q Q A B 078-132J-Q SA B 079-132A -Q SA B
3 3 5 208V 0-1-0 077-132A -Q R A B 078-132J-Q TA B 079-132A -Q TA B
Product Codes 360 Rotary Power Factor
For connection diagram s, see Fig. 4, 6 and 7 on page 58.
360 rotating iron products are only suitable for use on 50 and 60 H z system s.
Specifications
3-phase 4-w ire pow er factor m eters M odel -136 unbalanced load,
are connected L-L ie.. -132 balanced load
120V L-N system w ill be rated at 208V L-L. U L approved file no. E203000
48
360 Rotary Synchroscope
Product Codes Pivot and J ewel
R ating, self-contained: 120V A C
Frequency rating: 50 or 60H z (specify), 400H z optional
N orm al operating position: O n vertical panel unless otherw ise specified at tim e
of order
Position influence: N ot m ore than 3.6 m echanical degrees deviation for
up to 60 tilt from norm al operating position.
A ccuracy: 2 degrees
O vershoot: 33% m axim um
R esponse tim e: 3 seconds m axim um for 180 deflection
Sensitivity at synchronism : 3 electrical degrees m axim um
External field influence: 3% m axim um in 5 oersted field
Pull in frequency: 58H z
D rop-out frequency: 57H z
D ielectric test: Live parts to case, including panel: 2600V R M S
for 1 m inute.
B etw een running and 1500V R M S for 1 m inute
incom ing circuits:
O verload capacity: 50% indefinitely
Characteristics Incoming circuit Running circuit
Im pedance ohm s: 4670 5335
R esistance ohm s: 4020 5240
R esistance ohm s: 2380 1058
R eactive volt am ps: 1.57 0.535
Volt-am ps: 3.08 2.7
Pow er factor: 0.86 0.98
W atts: 2.66 2.65
360 Rotary Synchroscope
For connection diagram s, see Fig. 10 on page 59.
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
120V 50H z SLO W FA ST /+ 077-145A -PR A E-C 5 078-145J-PR A E-C 5 079-145A -PR A E-C 5
120V 60H z SLO W FA ST /+ 077-146A -PR A E-C 6 078-146J-PR A E-C 6 079-146A -PR A E-C 6
120V 400H z SLO W FA ST 077-144A -PR A E-C 4 078-144J-PR A E-C 4 079-144A -PR A E-C 4
Specifications
A lternate voltage of 240V, use code R R U L approved file no. E203000
instead of PR .
49
Product Codes
Voltage: 120, 240, 480 Volts A C or via PT
Frequency: 40/65H z
B urden @ 60H z: 4VA m axim um
Suitable for single or three-phase system s
Safety: IEC 1010-1(300V A C R M S installation degree 2)
D ielectric: 4kV R M S for 1 m inute
Isolation: B U S/G EN /R ELA Y
Vibration: M eets Lloyds shipping specifications
360 AC LED Synchroscope
Voltage: 110/120V (115V nom inal)
220/240V (230V nom inal)
380/480V (430V nom inal)
Phase difference: + 0 to 20 1
Voltage difference: + 0 to 20% 2%
Tim e delay: 0 to 2.5 seconds + 10%
AC Synchrocheck Relay and LED 360 Synchroscope
360 AC LED Synchroscope
AC Synchrocheck Relay
and LED 360 Synchroscope
For connection diagram s, see Fig. 8 on page 58.
For connection diagram s, see Fig. 9 on page 58.
4
1
2" square flange
Rating Scaling standard case
catalogue no.
120V 40/65H z SLO W FA ST 077-14A U -PQ YY-FQ
240V 40/65H z SLO W FA ST 077-14A U -R R YY-FQ
480V 40/65H z SLO W FA ST 077-14A U -SEYY-FQ
Product Codes
4
1
2" square flange
Rating Scaling standard case
catalogue no.
Live B us
110/120V 40/65H z SLO W FA ST 077-14G U -PO YY-FQ
220/240V 40/65H z SLO W FA ST 077-14G U -R SYY-FQ
380/480V 40/65H z SLO W FA ST 077-14G U -SZYY-FQ
D ead B us
110/120V 40/65H z SLO W FA ST 077-14H U -PO YY-FQ
220/240V 40/65H z SLO W FA ST 077-14H U -R SYY-FQ
380/480V 40/65H z SLO W FA ST 077-14H U -SZYY-FQ
Live B us
120V 40/65H z SLO W FA ST 077-14LU -PQ YY-FQ
240V 40/65H z SLO W FA ST 077-14LU -R R YY-FQ
480V 40/65H z SLO W FA ST 077-14LU -SEYY-FQ
D ead B us
120V 40/65H z SLO W FA ST 077-14D U -PQ YY-FQ
240V 40/65H z SLO W FA ST 077-14D U -R R YY-FQ
480V 40/65H z SLO W FA ST 077-14D U -SEYY-FQ
In the 0.77-14G and 0.77-14H m odels, the generator voltage is free to track the bus
voltage (+ the voltage difference preset) over the input voltage range. In the 077-14L
and 077-14D m odels, the generator voltage is to m atch the nom inal input (bus)
voltage specified (w ithin the voltage difference preset)
Specifications
Specifications
50
DC Transducer Indicator
AC Watt/Watt Hour Meter
Product Codes
DC Transducer Indicators
AC Watt and Watt Hour Meters
M oving coil indication gives instantaneous w att reading. A n im pulse
counter driven by self-contained circuitry gives the w att hour indication.
Product Codes Self Contained - (Accuracy Instantaneous 1%)
Kilow att hour 0.5% of pulse rate/hour.
Single Element, Transformer Rated 50/60Hz, Hi-Q Taut Band with Integral Transducer
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
W atts 1m A To suit /+ 077-055A -FA ** 078-055J-FA ** 079-055A -FA **
VA rs 1m A To suit /+ 077-056A -FA ** 078-056J-FA ** 079-056A -FA **
Frequency 1m A To suit /+ 077-053A -FA ** 078-053J-FA ** 079-053A -FA **
Pow er factor 1m A To suit /+ 077-054A -FA ** 078-054J-FA ** 079-054A -FA **
A C am ps 1m A To suit /+ 077-05A A -FA ** 078-05A J-FA ** 079-05A A -FA **
A C volts 1m A To suit /+ 077-05VA -LT** 078-05VJ-LT** 079-05VA -LT**
Speed 1m A To suit /+ 077-052A -FA ** 078-052J-FA ** 079-052A -FA **
VA 1m A To suit /+ 077-057A -FA ** 078-057J-FA ** 079-057A -FA **
4
1
2" square flange 8
3
4" square flange
Rating Scaling*
Standard case Sealed case hi-shock Standard case
catalogue no. catalogue no. catalogue no.
120V, 240V 1m A To suit 077-KH A U -FA ** 078-KH A J-FA ** -
50/60H z 4-20m A 077-KH A U -H G ** 078-KH A J-H G ** -
For use w ith the follow ing transducers:- * C ase types 077/078/079 use 10-32
w atts, VA rs, frequency, pow er factor, U N F term inals. For M 5 screw clam p
A C am peres, A C volts and tem perature term inals, use case type 075
** Specify scale. Input: 1m A D C for
4/20m A change FA to H G
For connection diagram s, see Fig. 19 on page 59
Measured 4
1
2" square flange 8
3
4" square flange
system
Scales Standard case Sealed case Standard case
catalogue no. hi-shock catalogue no.
catalogue no.
P
h
a
s
e
s
W
i
r
e
s
A
m
p
e
r
e
s
2

V
A

m
a
x
.

b
u
r
d
e
n
V
o
l
t
s
1

V
A

m
a
x
.

b
u
r
d
e
n
1 2 5 120 To suit 077-KH B U -Q Q ** 078-KH B J-Q Q ** -
For connection diagram s, see Fig. 21 on page 60.
For connection diagram s, see Fig. 25 on page 60.
For connection diagram s, see Fig. 28 on page 60.
3 3 5 120 To suit 077-KH EU -Q Q ** 078-KH EJ-Q Q ** -
3 3 5 208 To suit 077-KH EU -Q R ** 078-KH EJ-Q R ** -
3 4 5 69 To suit 077-KH G U -Q L** 078-KH G J-Q L** -
3 4 5 120 To suit 077-KH G U -Q Q ** 078-KH G J-Q Q ** -
3 4 5 277 To suit 077-KH G U -Q Y** 078-KH G J-Q Y** -
2-Element, Transformer Rated 50/60Hz, Hi-Q Taut Band with Integral Transducer
2
1
2-Element, Transformer Rated 50/60Hz, Hi-Q Taut Band with Integral Transducer
** Specify pulse rate and external pow er supply. U L approved file no. E203000
Product Codes Transducer Driven (Accuracy 1%)
Externally pow ered m eter w ith internal linear integrator and six digit im pulse counter.
51
Features
R ugged shock and vibration resistant
taut band design
H igh accuracy LED display
W ide selection of A C and D C inputs
M axim um trend indication visibility
Input isolation
External decim al point selection option
Interchangeable w ith 4
1
2" sw itchboard
m eters
Benefits
C ost effective
M eets all the requirem ents of
A N SI-C 39.1 (1981)
IP54 (N EM A 3) protection.
O ptional IP55 (N EM A 4) gasket
B um p, shock and vibration proof
C ustom ised options and features
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
B uilding m anagem ent
U tility pow er m onitoring
Process control
M otor control
Approvals
U L approved file no. E203000
LED Digital / Analogue Combination
C rom pton m odel 077-D I features a com bination of the traditional 250
4
1
2" sw itchboard indicator w ith the benefits of w ide angle visibility plus
trend indication. This rugged shock and vibration resistant taut band
design provides precision accuracy and instantaneous reading via the
bright in-dial m ounted 3
1
2" digit LED display.
Description
M odel 077-D I digital analogue indicators are ideal for all applications w here m oving
pointer instrum ents are preferable to indicate trend w ith the sim ultaneous display of a
high visibility precision LED readout for increased user interface.
Packaged in a w eather resistant case, the 077-D I is interchangeable w ith other analogue
and digital instrum ents designed to directly m ount in to a standard A N SI-C 39.
4
1
2"sw itchboard cut-out.
A vailable in side, center, or off-set zero versions, the 077-D I can accept A C current,
voltage, frequency, w atts, VA r and phase angle or D C current and voltage direct inputs as
w ell as a w ide range of transducer outputs, m aking it suitable for a variety of other
applications including low -load current, tem perature, speed, w att/VA rs,percent and level.
Inputs: D C Voltage: 20m V-600V (1M input im pedance as standard)
D C C urrent: 1m A -1A , 4 to 20m A (Voltage drop 200m V nom inal).
External shunt operation (50m V and 100m V).
A C Voltage: 200m V-600V (1 k / volt)
A C C urrent: 1m A -999m A (U sing internal shunt,
voltage drop 200m V nom inal). 1A , 2A , 5A and 10A
using internal current transform er.
C om m on m ode rejection: = > 80dB @ 50/60H z
O verload: Voltage: x 1.2 continuous. x1.5 for 10 seconds.
C urrent using internal C T: x 1.2 continuous.
x 10 for 10 seconds.
External pow er requirem ent: Standard: 120 and 240V 15% .
O ptional: 480V 15% A C 40-60H z
B urden: 3VA @ 60H z
D C : Standard: 12, 24, 48,110 and 125V 15%
D isplay analogue: long-scale m oving coil. 250 deflection. Scale
length 6.8inches. R esponse tim e less than 2.5 seconds.
D isplay options: C enter or offset zero. Scale plate in colours other than
w hite. C oloured lines or segm ents on scale.
Slow er response tim e.
D igital display: 3
1
2 digit red LED . 7 segm ent (7.6m m , 0.3" high).
R ight hand decim al points. Polarity indication:
positive / none. N egative / horizontal bar - .
U pdate tim e (standard): 1 per second
A ccuracy analogue: D C and A C 1% of FSD (calibrated at 25C )
A ccuracy digital: D C : 0.05% of reading 1 count 100ppm of
reading / C . (M axim um ).
A C current: 0-1 A m p 0.1% reading 3 counts
150ppm of reading / C .
A C current: 0-10 am ps 0.1% reading 10 counts
150ppm of reading / C (m axim um )
A C voltage: 0.1% of reading 3 counts 150ppm of
reading / C . (m axim um )
Zero 1 count 0.2 counts/C (m axim um ),
D C offset scale only. W arm -up tim e: 1 m inute
Long term stability: 2 counts
C alibration check: R ecom m ended 12 m onthly intervals
Enclosure code: IP54 (optional IP55 using panel gasket)
O perational tem perature: 0 to 60C (32 to 140F).
Storage tem perature: -20 to 60C (-4 to 140F)
H um idity: U p to 90% relative @ 55C . Tests to B S2011 part 2D A .
Isolation test voltage: 2kV R M S 60H z for 1 m inute
Interference rejection: To IEEE STD 472, A N SI C 37 90A ,
SEN 361503, IEC 255-4
A pprovals: EM C and LVD
U L approved file no. E203000
Specifications
52
Product Codes AC Voltmeters Direct Reading (40/2000Hz)***
(D igital accuracy 0.1% 3 counts, analogue accuracy 1% )
LED Digital/Analogue Combination
Product Codes AC Voltmeters Transformer Rated (40/2000Hz)***
M U - 12V D C PQ - 120V A C
Z2 - 130V D C PR - 120V D C
B D - 24V D C R R - 240V A C
PO - 115V A C PS - 125V D C
N R - 48V D C
AC Voltmeter
AC Ammeter
Rating Scaling* Catalogue no.
200m V 0-200m V 077-D IW A -KA KA -C 6-**
250m V 0-250m V 077-D IW A -KD KD -C 6-**
500m V 0-500m V 077-D IW A -KM KM -C 6-**
1V 0-1V 077-D IW A -LA LA -C 6-**
5V 0-5V 077-D IW A -LSLS-C 6-**
10V 0-10V 077-D IW A -M TM T-C 6-**
15V 0-15V 077-D IW A -N D N D -C 6-**
30V 0-30V 077-D IW A -N LN L-C 6-**
150V 0-150V 077-D IW A -PZPZ-C 6-**
250V 0-250V 077-D IW A -R SR S-C 6-**
300V 0-300V 077-D IW A -R XR X-C 6-**
500V 0-500V 077-D IW A -SFSF-C 6-**
600V 0-600V 077-D IW A -SJSJ-C 6-**
For connection diagram s, see Fig. 46 on page 62.
Rating Scaling* Catalogue no.
150V 0-300V 077-D IW A -PZR X-C 6-**
150V 0-600V 077-D IW A -PZSJ-C 6-**
150V 0-750V 077-D IW A -PZSM -C 6-**
150V 0-3000V 077-D IW A -PZU A -C 6-**
143V 0-5000V 077-D IW A -PTU J-C 6-**
150V 0-5250V 077-D IW A -PZU L-C 6-**
150V 0-6000V 077-D IW A -PZU P-C 6-**
150V 0-9000V 077-D IW A -PZU Y-C 6-**
150V 0-15KV 077-D IW A -PZW C -C 6-**
150V 0-18KV 077-D IW A -PZW D -C 6-**
150V 0-45KV 077-D IW A -PZW J-C 6-**
150V 0-60KV 077-D IW A -PZW L-C 6-**
For connection diagram s, see Fig. 45 on page 62.
Product Codes AC Ammeters Direct Reading (40/2000Hz)***
Rating Scaling* Catalogue no.
1A 0-1A 077-D IB A -LA LA -C 6-**
1.5A 0-1.5A 077-D IB A -LC LC -C 6-**
2A 0-2A 077-D IB A -LELE-C 6-**
3A 0-3A 077-D IB A -LJLJ-C 6-**
5A 0-5A 077-D IB A -LSLS-C 6-**
8A 0-8A 077-D IB A -M JM J-C 6-**
10A 0-10A 077-D IB A -M TM T-C 6-**
For connection diagram s, see Fig. 45 on page 62.
Product Codes Power Supply
* O ther scalings available.
** Specify pow er supply voltage according to Pow er Supply C odes table.
*** C ase types 077/078/079 use 10-32 U N F term inals.
For M 5 screw clam p term inals, use case type 075.
53
Product Codes AC Ammeters Transformer Rated (40/2000Hz)
(D igital accuracy 0.1% 1 counts, analogue accuracy 1% )
LED Digital/Analogue Combination
AC Ammeter
AC Frequency Meter
Rating Scaling* Catalogue no.
5A 0-15A 077-D IB A -LSN D -C 6-**
5A 0-20A 077-D IB A -LSN G -C 6-**
5A 0-25A 077-D IB A -LSN J-C 6-**
5A 0-30A 077-D IB A -LSN L-C 6-**
5A 0-40A 077-D IB A -LSN P-C 6-**
5A 0-50A 077-D IB A -LSN T-C 6-**
5A 0-60A 077-D IB A -LSN W -C 6-**
5A 0-75A 077-D IB A -LSPB -C 6-**
5A 0-80A 077-D IB A -LSPD -C 6-**
5A 0-100A 077-D IB A -LSPK-C 6-**
5A 0-150A 077-D IB A -LSPZ-C 6-**
5A 0-200A 077-D IB A -LSR L-C 6-**
5A 0-250A 077-D IB A -LSR S-C 6-**
5A 0-300A 077-D IB A -LSR X-C 6-**
5A 0-400A 077-D IB A -LSSC -C 6-**
5A 0-500A 077-D IB A -LSSF-C 6-**
5A 0-600A 077-D IB A -LSSJ-C 6-**
5A 0-750A 077-D IB A -LSSM -C 6-**
5A 0-800A 077-D IB A -LSSN -C 6-**
5A 0-1000A 077-D IB A -LSSS-C 6-**
5A 0-1200A 077-D IB A -LSSU -C 6-**
5A 0-1500A 077-D IB A -LSTC -C 6-**
5A 0-1600A 077-D IB A -LSTE-C 6-**
For connection diagram s, see Fig. 45 on page 62.
Centre Accuracy Scaling* Catalogue no.
frequency
50H z 0.15 45-55H z 077-D ZLA -PN A G -A G
50H z 0.15 46-54H z 077-D ZLA -PN A H -A H
55H z 0.25 45-65H z 077-D ZLA -PN A J-A J
60H z 0.25 50-70H z 077-D ZLA -PN A L-A L
60H z 0.15 55-65H z 077-D ZLA -PN A N -A N
60H z 0.15 56-64H z 077-D ZLA -PN A O -A O
60H z 0.08 58-62H z 077-D ZLA -PN A T-A T
400H z 1.3 350-450H z 077-D ZLA -PN B H -B H
400H z 1.25 360-440H z 077-D ZLA -PN B I-B I
400H z 0.08 380-420H z 077-D ZLA -PN B K-B K
For connection diagram s, see Fig. 44 on page 62.
Product Codes AC Frequency Meters
Self contained m eter w ith a 110/130 voltage rating and a m oving coil indicator
integral transducer
M U - 12V D C PQ - 120V A C
Z2 - 130V D C PR - 120V D C
B D - 24V D C R R - 240V A C
PO - 115V A C PS - 125V D C
N R - 48V D C
Product Codes Power Supply
For alternative voltage rating 200/250V, specify R N instead of PN .
For alternative voltage rating 380/480V, specify SE instead of PN .
* O ther scales are available.
** Specify pow er supply voltage, according to Pow er Supply C odes table.
54
Product Codes DC Voltmeters Direct Reading
(D igital accuracy 0.5% 1 counts, analogue accuracy 1% )
LED Digital/Analogue Combination
Rating Scaling* Catalogue no.
200m V 0-200m V 077-D IVA -KA KA -**
250m V 0-250m V 077-D IVA -KD KD -**
500m V 0-500m V 077-D IVA -KM KM -**
1V 0-1V 077-D IVA -LA LA -**
5V 0-5V 077-D IVA -LSLS -**
10V 0-10V 077-D IVA -M TM T-**
15V 0-15V 077-D IVA -N D N D -**
30V 0-30V 077-D IVA -N LN L -**
50V 0-50V 077-D IVA -N TN T -**
75V 0-75V 077-D IVA -PB PB -**
80V 0-80V 077-D IVA -PD PD -**
150V 0-150V 077-D IVA -PZPZ -**
300V 0-300V 077-D IVA -R XR X -**
400V 0-400V 077-D IVA -SC SC -**
500V 0-500V 077-D IVA -SFSF-**
600V 0-600V 077-D IVA -SJSJ-**
150-0-150V 150-0-150V 077-D IN A -R XR X-**
300-0-300V 300-0-300V 077-D IN A -SJSJ -**
600-0-600V 600-0-600V 077-D IN A -SU SU -**
For connection diagram s, see Fig. 45 on page 62.
DC Voltmeter
55
Product Codes DC Ammeters Shunt Rated
(D igital accuracy 0.5% 1 counts, analogue accuracy 1% )
LED Digital/Analogue Combination
Product Codes DC Ammeters Suppressed Zero
(D igital accuracy 0.5% 1 counts, analogue accuracy 1% )
DC Ammeter
Rating Scaling* Catalogue no.
50m V-4m A 077-D IA A -EY
50-0-50m V-2-0-2m A 077-D IC A -G B
100-0-100m V 077-D IC A -G M
100-0-100m V-2-0-2m A 077-D IC A -FM
For connection diagram s, see Fig. 45 on page 62.
Rating Scaling* Catalogue no.
1-5m A 077-D IA A -G M
4-20m A 077-D IA A -H G
10-50m A 077-D IA A -H Z
For connection diagram s, see Fig. 45 on page 62.
Product Codes DC Ammeters Direct Reading
(D igital accuracy 0.5% 1 counts, analogue accuracy 1% )
Rating Scaling* Catalogue no.
1m A 0-1m A 077-D IA A -FA FA -**
2m A 0-2m A 077-D IA A -FG FG -**
5m A 0-5m A 077-D IA A -FXFY-**
10m A 0-10m A 077-D IA A -G ZG Z-**
20m A 0-20m A 077-D IA A -H FH F-**
30m A 0-30m A 077-D IA A -H M H M -**
50m A 0-50m A 077-D IA A -H YH Y-**
100m A 0-100m A 077-D IA A -JR JR -**
200m A 0-200m A 077-D IA A -KA KA -**
300m A 0-300m A 077-D IA A -KG KG -**
500m A 0-500m A 077-D IA A -KM KM -**
800m A 0-800m A 077-D IA A -KW KW -**
1A 0-1A 077-D IA A -LA LA -**
For connection diagram s, see Fig. 45 on page 62.
M U - 12V D C PQ - 120V A C
Z2 - 130V D C PR - 120V D C
B D - 24V D C R R - 240V A C
PO - 115V A C PS - 125V D C
N R - 48V D C
Product Codes Power Supply
* O ther scales are available.
** Speedy pow er supply voltage according to Pow er Supply C odes table.
Scaled to
suit
standard
shunt ratings
To suit
requirem ents
56
Product Codes AC Wattmeters, Single Phase 50/60Hz (Accuracy 1%)
LED Digital/Analogue Combination
Product Codes AC Wattmeters, 2 Element, Transformer Rated, 50/60Hz,
Integral Transducer (Accuracy 1.0%)
AC Wattmeter
AC VArmeter
Power Factor/Phase Angle Meter ** Specify C T (C urrent Transform er) and VT (Voltage Transform er) ratios if
used, and preferred scale at tim e of ordering.
Measured
system
4
1
2" square flange
Scales standard case
catalogue no.
P
h
a
s
e
s
W
i
r
e
s
A
m
p
e
r
e
s
1

V
A

m
a
x
.

b
u
r
d
e
n
V
o
l
t
s
1

V
A

m
a
x
.

b
u
r
d
e
n
1 2 5A 120V To suit 077-D W 5A -Q Q **-C 6
1 2 5A 240V To suit 077-D W 5A -Q S**-C 6
For connection diagram , see Fig. 37 on page 61.
For connection diagram , see Fig. 38 on page 62.
3 3 5A 120V To suit 077-D W 8A -Q Q **-C 6
3 3 5A 240V To suit 077-D W 8A -Q R **-C 6
Product Codes AC Wattmeters, 3 Element, Transformer Rated, 50/60Hz,
Integral Transducer
For connection diagram , see Fig. 39 on page 62.
3 4 5A 69V To suit 077-D W 9A -Q L**-C 6
3 4 5A 120V To suit 077-D W 9A -Q Q **-C 6
Product Codes AC VArmeters, 2 Element, Transformer Rated, 50/60Hz,
Integral Transducer
For connection diagram , see Fig. 40 on page 62.
3 3 5A 120V To suit 077-D XLA -Q Q **-C 6
3 3 5A 208V To suit 077-D XLA -Q R **-C 6
Product Codes AC VArmeters, 2 Element, Transformer Rated, 50/60Hz,
Integral Transducer
For connection diagram , see Fig. 41 on page 62.
3 4 5A 120V To suit 077-D XU A -Q Q **-C 6
3 4 5A 208V To suit 077-D XU A -Q R **-C 6
Product Codes Power Factor and Phase Angle Meters. Accuracy 1.0%
(Balanced Loads), Self Contained, 60Hz, Integral Transducer
For connection diagram , see Fig. 42 and 43 on page 62.
1 2 5A 120V 0.5-1-0.5 LA G /LEA D and 60/0/60 D EG 077-D P5A -Q Q A D -C 6
1 2 5A 240V 0.5-1-0.5 LA G /LEA D and 60/0/60 D EG 077-D P5A -Q SA D -C 6
3 34 5A 120V 0.5-1-0.5 LA G /LEA D and 60/0/60 D EG 077-D P7A -Q Q A D -C 6
3 34 5A 208V 0.5-1-0.5 LA G /LEA D and 60/0/60 D EG 077-D P7A -Q R A D -C 6
3 34 5A 240V 0.5-1-0.5 LA G /LEA D and 60/0/60 D EG 077-D P7A -Q SA D -C 6
3 34 5A 480V 0.5-1-0.5 LA G /LEA D and 60/0/60 D EG 077-D P7A -Q TA D -C 6
57
Scale Options
LED Digital/Analogue Combination
Calibration Options
Options Option code
1. B lank, uncalibrated dial (zero and full scale m arks in pencil). SA
2. R ed or coloured line or m ark (specify position). SR
3. C oloured zones or segm ents (specify lim its and colour(s). SZ
4. N on-standard caption (other than listed below ). SD
5. B lack dial w ith w hite figures and pointer. SB
6. C ustom er/user logo im printed on dial. SM
7. Finely divided scale. -
8. Standard rating, single unlisted scale -
Options Option code
10. Zero-center scale. N ot available for A C am m eters and voltm eters -
11. O ffset-zero scale w attm eters, VA rm eters, D C am m eters
and voltm eters. -
12. C alibration to custom er specification including special caption. -
13. C alibration other than vertical, specify required angle
from vertical. C M
14. N on-listed ratings. -
15. Tem perature calibration, other than 23C am bient. C T
16. a) C alibration at 400H z. C 4
b) C alibration to other specific frequencies betw een 25 and 500H z.
17. Potentiom eter, externally m ounted 10% range adjustm ent. -
18. Suppressed zero other than listed. D C only. R A
19. H eavily dam ped m ovem ent. PD
Construction Options
Options Option code
20. A nti-glare w indow . B R
21. Internal illum ination. Specify 6, 12, 24 or 36V D C EL
22. *N eoprene
TM
polychloroprene panel basket. M G
23. R ed m anual set pointer. ER
25. C oloured bezel. FA
26. H erm etically sealed case. -
*N eoprene is a Tradem ark of E.I. D uPont de N em ours.
58
Connection Diagrams
Fig. 1M odel 077-12P
Phase Sequence Indicator 3-Phase
3- or 4-W ire system s
Fig. 2M odel 077-137
360 D ynam om eter Pow er Factor
Indicator Single Phase
Fig. 3 M odel 077-131
360 D ynam om eter Pow er Factor
Indicator 3-Phase 3- or 4-W ire B alanced
Load (3 C urrents 1 Voltage)
Fig. 6M odels 077-136, 077-136A ,
078-136J
360 D ynam om eter Pow er Factor
Indicator 3-Phase 3- or 4-W ire
U nbalanced Load
Fig. 5M odel 078-132B
360 D ynam om eter Pow er Factor
Indicator Indicator 3-Phase 3- or 4-W ire
B alanced Load (1 C urrent 3 Voltages)
Fig. 4M odels 077-132, 078-132J
360 D ynam om eter Pow er Factor
Indicator 3-Phase 3- or 4-W ire B alanced
Load (1 C urrent 3 Voltages)
Fig. 7M odel 078-136B
360 D ynam om eter Pow er Factor
Indicator 3-Phase 3- or 4-W ire
U nbalanced Load
Fig. 8M odels 077-14A
360 LED Synchroscope
Fig. 9M odels 077-14D , 077-14G ,
077-14H , 077-14L
360 LED Synchroscope and
Synchro C heck R elay
59
Connection Diagrams
Fig. 10M odels 077-144, 077-145
077-146, 077-147, 078-144J, 078-145J
078-146J, 078-147J, 079-144, 079-145
079-146
360 D ynam om eter Synchroscope
Fig. 11M odels 078-144B , 078-145B
078-146B , 078-147B
360 D ynam om eter Synchroscope
Fig. 12M odel 077-TFU
Pow er Factor M eter 3-Phase 3-W ire
U nbalanced Load
Fig. 15M odels 075-427, 077-427
078-427J, 079-427
Electronic Phase A ngle M eter 3-phase
3- or 4-w ire B alanced Load
Fig. 14M odel 078-425B
Electronic Phase A ngle M eter
Single Phase
Fig. 13M odels 077-425, 078-425J
079-425
Electronic Phase A ngle M eter
Single Phase
Fig. 16M odel 078-427B
Electronic Phase A ngle M eter 3-Phase
3- or 4-W ire B alanced Load
Fig. 17M odels 077-45R , 078-45R
Tem perature Indicator for R esistance
Tem perature D etector (R TD )
Fig. 18M odel 077-45T
Tem perature Indicator for
Therm ocouple D etector
Fig. 19M odels 077-KH A , 078-KH A
A C Kilow atts/Kilow atthours
(Transducer) Indicator
60
Connection Diagrams
Fig. 20M odel 077-45P
Tap Position Indicator
Fig. 21M odels 077-215, 077-KH B
078-215J, 078-KH B J, 079-215
W attm eter Single Phase
Fig. 22M odel 078-215B , 078-KH B B
W attm eter Single Phase
Fig. 25M odels 077-218, 077-KH E
078-218J, 078-KH EJ, 079-218
W attm eter 3-Phase 3-W ire
U nbalanced Load
Fig. 24M odel 078-216B
W attm eter 3-Phase 3-W ire
B alanced Load
Fig. 23M odels 077-216, 078-216J
W attm eter 3-Phase 3-W ire
B alanced Load
Fig. 26M odels 078-218B , 078-KH EB
W attm eter 3-Phase 3-W ire
U nbalanced Load
Fig. 27M odel 077-21D
W attm eter 3-Phase 4-W ire
B alanced Load
Fig. 28M odels 077-219, 077-KH G
078-219J, 078-KH G J, 079-219
W attm eter 3-Phase 4-W ire
U nbalanced Load
61
Connection Diagrams
Fig. 29M odels 078-219B , 078-KH G B
W attm eter 3-Phase 4-W ire
U nbalanced Load
Fig. 30M odels 077-21B
W attm eter 3-Phase 3-W ire B alanced Load
2 R everse C onnected C Ts
Fig. 31M odel 077-21F
W attm eter 3-Phase 4-W ire U nbalanced
Load D elta C onnected C Ts
Fig. 34M odel 077-319
VA rm eter 3-Phase 4-W ire
U nbalanced Load
Fig. 33M odels 077-315
VA rm eter 3-Phase 3- or 4-W ire
B alanced Load
Fig. 32M odels 077-31L, 078-31LJ
VA rm eter 3-Phase 3-W ire
U nbalanced Load
Fig. 35M odels 077-31U , 077-KXG
078-31U , 079-31U
VA rm eter 3-Phase 4-W ire
U nbalanced Load
Fig. 36M odel 077-31F
VA rm eter 3-Phase 4-W ire U nbalanced
Load D elta C onnected C Ts
Fig. 37M odel 077-D W 5
LED D igital/A nalogue W attm eter
Single Phase
62
Connection Diagrams
Fig. 38M odel 077-D W 8
LED D igital/A nalogue W attm eter 3-Phase
3-W ire U nbalanced Load
Fig. 39M odel 077-D W 9
LED D igital/A nalogue W attm eter
3-Phase 4-W ire U nbalanced Load
Fig. 40M odel 077-D XL
LED D igital/A nalogue VA rm eter 3-Phase
3-W ire U nbalanced Load
Fig. 43M odel 077-D P7
LED D igital/A nalogue Phase A ngle M eter
3-Phase 3- or 4-W ire B alanced Load
Fig. 42M odel 077-D P5
LED D igital/A nalogue Phase A ngle M eter
Single Phase
Fig. 41M odel 077-D XU
LED D igital/A nalogue VA rm eter 3-Phase
4-W ire U nbalanced Load
Fig. 44M odel 077-D ZL
LED D igital/A nalogue Frequency M eter
Fig. 45M odels 077-D I2, 077-D IA
077-D IB , 077-D IC , 077-D IN , 077-D IT
077-D IV, 077-D IW
LED D igital/A nalogue M eter
Fig. 46M odels 077-D A 2, 077-D A A
077-D A B , 077-D A K, 077-D A T
077-D A V, 077-D A W
LC D D igital/A nalogue M eter
63
Specifications
549 Series Panel Meters
C om pact panel m eters designed to fit standard 17/32" sw itch knock-outs.
This range includes high accuracy A C and D C am m eters and voltm eters,
elapsed tim e m eters and im pulse counters.
Dimensions
Enclosure code: IP42 (IEC 529)
System frequencies: A C A m m eters: 50, 60 or 400H z
A C Voltm eters: 50 or 60H z
Elapsed Tim e M eter: 50 or 60H z
System voltage: Elapsed Tim e M eter: 110/130V A C , 200/250V A C ,
6 or 12V D C
Input ratings available: A C A m m eter: 50m A -5A (self contained) extendible
to 50A w ith external w ound prim ary C T
A C Voltm eter: 30-600V
D C A m m eter: 100A -20m A
D C Voltm eter: 50m V-600V
Scale: A ngle: 90. Length: 1 inch (26m m )
O perating tem perature: -10C to 55C (15 to 130F).
B ezel w indow : Toughened glass
Fixing on panel: Sim ple clam p fixing
A pprovals: EM C and LVD , A B S (A m erican B ureau of Shipping)
Features
C om pact size
Fits standard 17/32 inch sw itch
knock-outs
Toughened glass w indow
A C and D C am m eters and voltm eters
available
H ours runand im pulse counters
available
Benefits
Sim ple clam p fixing
Easy installation on replacem ent
Panel space saving
C ustom ised options and features
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
B uilding m anagem ent
U tility pow er m onitoring
Process control
M otor control
Approvals
A B S (A m erican B ureau of Shipping)
approved file no. 93-LD 17806-X
A B C D E* F G H I J K L M
in. 1.81 1.56 0.34 0.91 0.51 0.85 0.24 0.51 0.16 1.08 1.08 1.18
m m 46 39.6 8.6 23 13 21.6 6.1 13 4 27.5 27.5 30
R etaining C lip
Elapsed Time Meters
Panel Cut-Out
A B C D E F G H I J K L M
in. 1.84 1.59 0.34 1.75 0.51 0.86 0.24 0.51 0.16 1.08 1.08 1.18 1.18
m m 46.8 40.4 8.6 44.3 13 21.9 6 13 4.1 27.5 27.5 30 30
A B C D E
in. 1.2 0.57 0.25 1.09 015
m m 30.5 14.5 6.4 27.8 3.9
64
Product Codes Self Contained 50mA Rating For Use With Separately
Wound Primary Current Transformer
AC Ammeter
Input Scaling Catalogue no.
50m A 0-1A 549-78A A -H XLA
50m A 0-5A 549-78A A -H XLS
50m A 0-7.5A 549-78A A -H XM F
50m A 0-10A 549-78A A -H XM T
50m A 0-15A 549-78A A -H XN D
50m A 0-20A 549-78A A -H XN G
50m A 0-30A 549-78A A -H XN L
50m A 0-40A 549-78A A -H XN P
50m A 0-50A 549-78A A -H XN T
Product Codes Other Scales Available
AC Voltmeter
Input Scaling Catalogue no.
150V 0-150V 549-78VA -PZPZ
150V 0-300V 549-78VA -PZR X
150V 0-600V 549-78VA -PZSJ
150V 0-750V 549-78VA -PZSM
Product Codes
Elapsed Time Meter
Input Scaling Catalogue no.
110/130V A C , 50H z 99999.99 549-155A -PN C 5-ZH
110/130V A C , 60H z 99999.99 549-156A -PN C 6-ZH
200/250V A C , 50H z 99999.99 549-155A -R N C 5-ZH
200/250V A C , 60H z 99999.99 549-156A -R N C 6-ZH
6V D C , D C 99999.99 549-151A -LW ZH
12V D C , D C 99999.99 549-151A -M U ZH
Product Code
Impulse Counters
Input Scaling Catalogue no.
120V A C , 60H z 999999 549-257A -PQ C 6
Input Scaling Catalogue no.
5A 0-50A 549-78A A -LSN T
5A 0-60A 549-78A A -LSN W
5A 0-75A 549-78A A -LSPB
5A 0-80A 549-78A A -LSPD
5A 0-100A 549-78A A -LSPK
5A 0-150A 549-78A A -LSPZ
5A 0-200A 549-78A A -LSR L
5A 0-300A 549-78A A -LSR X
5A 0-400A 549-78A A -LSSC
5A 0-500A 549-78A A -LSSF
5A 0-600A 549-78A A -LSSJ
5A 0-800A 549-78A A -LSSN
5A 0-1000A 549-78A A -LSSS
5A 0-1200A 549-78A A -LSSU
5A 0-1500A 549-78A A -LSTC
5A 0-1600A 549-78A A -LSTE
5A 0-2000A 549-78A A -LSTM
AC Ammeter
Elapsed Time Meter
Product Codes For Use With External Current Transformers
Other Scales Available
65
Product Codes For Use With Current Shunts
DC Ammeter
DC Voltmeter
Input Scaling Catalogue no.
0-50m V 0-5 549-80A A -EC LS
0-50m V 0-10 549-80A A -EC M T
0-50m V 0-15 549-80A A -EC N D
0-50m V 0-20 549-80A A -EC N G
0-50m V 0-30 549-80A A -EC N L
0-50m V 0-50 549-80A A -EC N T
0-50m V 0-80 549-80A A -EC PD
0-50m V 0-100 549-80A A -EC PK
0-50m V 0-150 549-80A A -EC PZ
0-50m V 0-200 549-80A A -EC R L
0-50m V 0-250 549-80A A -EC R S
0-50m V 0-300 549-80A A -EC R X
0-50m V 0-400 549-80A A -EC SC
0-50m V 0-500 549-80A A -EC SF
0-50m V 0-600 549-80A A -EC SJ
0-50m V 0-800 549-80A A -EC SN
0-50m V 0-1000 549-80A A -EC SS
0-50m V 0-1200 549-80A A -EC SU
0-50m V 0-1500 549-80A A -EC TC
0-50m V 0-2000 549-80A A -EC TM
Product Code
DC Voltmeter
Input Scaling Catalogue no.
0-50m V to 0-150V To suit 549-80VA -****
Product Codes Direct Connected
Input Scaling Catalogue no.
0-100A To suit 549-80A A -D R **
0-1m A To suit 549-80A A -FA **
0-20m A To suit 549-80A A -H F**
4-20m A To suit 549-80A A -H G *
** Specify scale required. 100m V shunt rated D C am m eters
**** Specify input and scale required. are available, replace the code EC
w ith G B .
66
Saxon Indicators
A range of 2
1
/2", 3
1
/2" and 4
1
/2" surface m ount panel m eters utilising pivot
and jew el m echanism s and offering IP54 protection. The range includes
iron vane and m oving coil A C and D C am m eters and voltm eters,
elapsed tim e and frequency m eters designed to perform in
dem anding environm ents.
Features
Three com pact case sizes
W ithstands high levels of shock,
vibration, dirt and hum idity
Pivot and jew el m echanism s
Benefits
C om plies w ith A N SI C 39.1 (IEC 51)
IP54 (N EM A 3) protection
Instrum ents com ply w ith B SEN 61010-1
and m eet IEC 414 (B S5458)
Pass dielectric test (2600V for 1m in)
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
B uilding m anagem ent
U tility pow er m onitoring
Process control
M otor control
Approvals
U L approved file no. E203000
Specifications Elapsed Time Meter and Frequency Meter
A ccuracy: 0.15 = 60H z, 1.25 = 400H z, 0.15 = 50H z, 0.25 = 55H z
Voltage: 110/130V, 200/250V
Frequency: 50H z or 60H z
B urden: 4VA M axim um
Specifications Moving Iron AC Ammeter and Voltmeter
A ccuracy: 2%
R ating: A m m eters: 1 - 30A
Voltm eters: 10V - 600V
O verload: A m m eters: x1.2 for 2 hours, x10 for 5 seconds
Voltm eters: x1.2 for 2 hours, x2 for 5 seconds
B urden: A m m eters: 0.5VA
Voltm eters: 4.5VA m axim um
Specifications Moving Coll DC Ammeter and Voltmeter
A ccuracy: 2%
R ating: A m m eters: 100A - 30A
Voltm eters: 50m V - 600V
O perating tem p: -20C to 60C (-4F to 140F)
Storage tem p: -30C to 70C (-22F to 158F)
Dimensions
Specify num ber of fixing studs w hen ordering 2
1
/2" and 3
1
/2" m eters. 4
1
/2" m eters are
supplied w ith 4 fixing studs.
Panel cut-out
A B C D E F G H J K L M N O P
2 12 m m 68.6 68.6 11.8 14.6 32.0 25.4 10.4 12.7 55.9 31 46.5 26.9 23.9 47.8 23.9
inch 2.70 2.70 0.46 0.57 1.26 1.00 0.41 0.50 2.20 1.22 1.83 1.06 0.94 1.88 0.94
3 12m m 88.9 88.9 11.8 14.6 36.0 25.4 10.4 12.7 69.9 40.2 60.3 34.8 28.5 57.0 28.5
inch 3.5 3.5 0.46 0.57 1.42 1.00 0.41 0.50 2.75 1.58 2.37 1.37 1.12 2.24 1.12
4 12m m 112.0 123.2 12.7 16.3 30.5 28.4 0.38 12.7 70.9 51.6 90.4 50.8
inch 4.41 4.85 0.50 0.64 1.20 1.12 0.41 0.50 2.78 2.03 3.56 2.00
67
AC Ammeter
AC Voltmeter
Frequency Meter
Product Codes AC Ammeter True RMS Reading (Accuracy 2% ES)
Rating Scaling Catalogue no.
5A 0-5A (01*)-75A A -LSLS-C 6-B *
10A 0-10A (01*)-75A A -M TM T-C 6-B *
15A 0-15A (01*)-75A A -N D N D -C 6-B *
20A 0-20A (01*)-75A A -N G N G -C 6-B *
30A 0-30A (01*)-75A A -N LN L-C 6-B *
1A Transform er rated (01*)-75A A -LA **-C 6-B *
5A Transform er rated (01*)-75A A -LS**-C 6-B *
Product Codes AC Voltmeter True RMS Reading (Accuracy 2% ES)
150V 0-150V (01*)-75VA -PZPZ-C 6-B *
300V 0-300V (01*)-75VA -R XR X-C 6-B *
600V 0-600V (01*)-75VA -SJSJ-C 6-B *
150V Transform er rated (01*)-75VA -PZ**-C 6-B *
Product Codes DC Ammeters (Accuracy 2% ES)
0-1m A To suit requirem ents (01*)-01A A -FA **-B *
0-5m A 0-5m A (01*)-01A A -FXFX-B *
0-10m A 0-10m A (01*)-01A A -G ZG Z-B *
0-20m A 0-20m A (01*)-01A A -H FH F-B *
0-50m A 0-50m A (01*)-01A A -H YH Y-B *
0-100m A 0-100m A (01*)-01A A -JR JR -B *
0-200m A 0-200m A (01*)-01A A -KA KA -B *
0-500m A 0-500m A (01*)-01A A -KM KM -B *
0-1A 0-1A (01*)-01A A -LA LA -B *
0-2A 0-2A (01*)-01A A -LELE-B *
0-5A 0-5A (01*)-01A A -LSLS-B *
0-10A 0-10A (01*)-01A A -M TM T-B *
0-50m V To suit (01*)-01A A -EC **-B *
Product Codes Milliammeters Suppressed Zero (Accuracy 2% ES)
4-20m A To suit requirem ents (01*)-01R A -H G **-B *
**Specify scale value
Product Codes DC Voltmeters Sensitivity 1000Volt (Accuracy 2% ES)
0-15V 0-15V (01*)-01VA -N D N D -B *
0-30V 0-30V (01*)-01VA -N LN L-B *
0-50V 0-50V (01*)-01VA -N TN T-B *
0-150V 0-150V (01*)-01VA -PZPZ-B *
0-300V 0-300V (01*)-01VA -R XR X-B *
0-600V 0-600V (01*)-01VA -SJSJ-B *
Product Codes Elapsed Time Meters 99999.99 hours, non-resetable
110/130V, 50H z (01*)-155A -PN ZH -C 5-B *
200/250V, 50H z (01*)-155A -R N ZH -C 5-B *
480V, 50H z (01*)-155A -SEZH -C 5-B *
110/130V, 60H z (01*)-156A -PN ZH -C 6-B *
200/250V, 60H z (01*)-156A -R N ZH -C 6-B *
480V, 60H z (01*)-156A -SEZH -C 6-B *
Product Codes Frequency Meters 120V, Self Contained
50H z 45-55H z (01*)-41SA -PN A G -A G -B *
55H z 45-65H z (01*)-41SA -PN A J-A J-B *
60H z 55-65H z (01*)-41SA -PN A N -A N -B *
To denote the required case size, replace the 01* in the catalogue num ber w ith 012,
013 or 014 for 2
1
/2", 3
1
/2" or 4
1
/2" respectively.
To denote the required stud fixing configuration, replace B * w ith B 2 (2 stud),
B 3 (3 stud) or B 4 (4 stud)
68
Features
C ontoured w indow providing an
exceptionally high view ing angle
W ithstands high levels of shock,
vibration, dirt and hum idity
Benefits
C om plies w ith A N SI C 39.1 (IEC 51)
IP55 (N EM A 4) protection
Instrum ents com ply w ith B SEN 61010-1
and m eet IEC 414 (B S5458)
D ielectric Test (2600V for 1m in)
C ustom ised options and features
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
U tility pow er m onitoring
Process control
M otor control
Approvals
U L approved file no. E87815
016 Series Fiesta Indicators
Specifications Elapsed Time Meter and Frequency Meter
A robust range of short-scale and long-scale 3
1
/2" surface m ount panel
m eters offering IP55 protection and featuring a w ide view contoured
w indow . The Fiesta range includes iron vane and m oving coil A C and D C
am m eters and voltm eters, elapsed tim e and frequency m eters and is
ideally suited for dem anding environm entals. O ptions include
supplem entary pointer, non-reflecting w indow , heavily dam ped m ovem ent
panel gasket, clam p band fixing long-scale and coloured internal gasket.
Voltage: 100/125V, 200/250V or 480V A C
Frequency: 50H z or 60H z
B urden: 4VA m axim um
O perating tem perature: -20C to 65C (-4F to 149F)
Storage tem perature: -30C to 70C (-22F to 158F)
A ccuracy: Short-scale: am m eters 2.5% ; long-scale: 1.5 %
R atings: A m m eters: short-scale 1 - 80A , long-scale 1 - 20A
Voltm eters: 10V - 600V
O verload: A m m eters: x1.2 for 2 hours, 10 x for 5 seconds
Voltm eters: x1.2 for 2 hours, 2 x for 5 seconds
B urden: A m m eters: short-scale 0.5VA ; long-scale 1.5VA
Voltm eters: 4.5VA m axim um
O perating tem perature: -20C to 65C (-4F to 149F)
Storage tem perature: -30C to 70C (-22F to 158F)
Specifications Iron Vane AC Ammeter and Voltmeter
A ccuracy: Short-scale 1.5; long-scale 1.5
R atings: A m m eters: 200A to 30A , (100A short-scale)
Voltm eters: 50m V - 600V
O verload: A m m eters: x1.2 for 2 hours, 10 x for 5 seconds
Voltm eters: x1.2 for 2 hours, 2 x for 5 seconds
Im pedance: Voltm eters: 1000 ohm s per nom inal volt
O perating tem perature: -20C to 65C (-4F to 149F)
Storage tem perature: -30C to 70C (-22F to 158F)
Specifications Moving Coil DC Ammeter and Voltmeter
Dimensions
Instrument Dim X inches Dim Xmm
M C . IN STS 1/4"-28 U N F 18.0
M I VO LTM ETER and A M M upto 59A 1/4"-28 U N F 18.0
M I A M M ETER 60A and over 5/16"-24 U N F 23.0
69
Product Codes True RMS Reading, Self Contained 50/60Hz
Product Codes Moving Coil Rectified
AC Ammeter Short-scale
AC Ammeter Long-scale
AC Overload Ammeter
AC Voltmeter
Rating Scaling
Short-scale Long-scale
catalogue no. catalogue no.
5A 0-5A 016-02A *-LSLS-C 7 016-03A *-LSLS-C 7
10A 0-10A 016-02A *-M TM T-C 7 016-03A *-M TM T-C 7
15A 0-15A 016-02A *-N D N D -C 7 016-03A *-N D N D -C 7
20A 0-20A 016-02A *-N G N G -C 7 016-03A *-N G N G -C 7
30A 0-30A 016-02A *-N LN L-C 7 016-03A *-N LN L-C 7
5A Transform er rated 016-02A *-LS**-C 7 016-03A *-LS**-C 7
100A - 1A To suit 016-01B *- 016-05B *-
Rating Scaling
Short-scale Long-scale
catalogue no. catalogue no.
5A 0-5-30A 016-026*-LSLS-C 7 016-036*-LSLS-C 7
10A 0-10-60A 016-026*-M TM T-C 7 016-036*-M TM T-C 7
15A 0-15-90A 016-026*-N D N D -C 7 016-036*-N D N D -C 7
20A 0-20-120A 016-026*-N G N G -C 7 016-036*-N G N G -C 7
30A 0-30-180A 016-026*-N LN L-C 7 016-036*-N LN L-C 7
5A Transform er rated 016-026*-LS**-C 7 016-036*-LS**-C 7
Product Code Moving Coil Rectified
15-600V To suit 016-01W *- 016-05W *-
Product Codes Milliammeters - No Zero Set Unless Specified
Product Codes Voltage Suppressed Zero - No Zero Set Unless Specified
4/20m A To suit 016-01R A *-H G ** 016-05R A -H G **
1-5V To suit 016-01S*-LM **
Product Code True RMS Reading
150V 0-150V 016-02V*-PZPZ-C 7 016-03V*-PZPZ-C 7
300V 0-300V 016-02V*-R XR X-C 7 016-03V*-R XR X-C 7
600V 0-600V 016-02V*-SJSJ-C 7 016-03V*-SJSJ-C 7
150V Transform er rated 016-02V*-PZ**-C 7 016-03V*-PZ**-C 7
AC Ammeter
Product Codes True RMS Reading, Self Contained 50/60Hz
AC Overload Ammeter
AC Voltmeter
Product Codes
150V 0-150V 016-02V*-PZPZ-C 7 016-03V*-PZPZ-C 7
0-50m V To suit 016-01A *-EC ** 016-05A *-EC **
0-1m A To suit 016-01A *-FA ** 016-05A *-FA **
0-5m A To suit 016-01A *-FX** 016-05A *-FX**
0-10m A To suit 016-01A *-H A ** 016-05A *-H A **
0-20m A To suit 016-01A *-H F** 016-05A *-H F**
DC Ammeters
Suppressed Zero
* Please state A or B at tim e of ordering. A = A N SI B = B S89
** C ustom er m ust state required scaling at tim e of ordering.
U L approved
70
Product Codes Sensitivity 1000/Volt
DC Voltmeters
DC Voltmeter
Frequency Meter
Elapsed Time Meter
Rating Scaling
Short-scale Long-scale
catalogue no. catalogue no.
0-15V 0-15V 016-01V*-N D N D 016-05V*-N D N D
0-30V 0-30V 016-01V*-N LN L 016-05V*-N LN L
0-50V 0-50V 016-01V*-N TN T 016-05V*-N TN T
0-150V 0-150V 016-01V*-PZPZ 016-05V*-PZPZ
0-300V 0-300V 016-01V*-R XR X 016-05V*-R XR X
0-600V 0-600V 016-01V*-SJSJ 016-05V*-SJSJ
Product Codes 120V, Self Contained
Frequency Meters
-
Short-scale Long-scale
Rating Scaling catalogue no. catalogue no.
Standard case
50H z centre
frequency, 45-55H z 016-41S*-PN A G -A G
-0.15 accuracy
55H z centre U se 016-053
frequency, 45-65H z 016-41S*-PN A J-A J plus 253-TH Z
-0.25 accuracy
60H z centre
frequency, 55-65H z 016-41S*-PN A N -A N
-0.15 accuracy
400H z centre
frequency, 360-440H z 016-41S*-PN B I-B I
-1.25 accuracy
Product Codes 99999.99 hours, Non-resettable
Elapsed Time Meters
Standard case
110/130V, 50H z 016-155*-PN ZH -C 5
200/250V, 50H z 016-155*-R N ZH -C 5
480V, 50H z 016-155*-SEZH -C 5
110/130V, 60H z 016-156*-PN ZH -C 6
200/250V, 60H z 016-156*-R N ZH -C 6
480V, 60H z 016-156*-SEZH -C 6
Product Codes DC Milliamp Rated
Transducer Indicators
Speed To suit 016-012* 016-052
Frequency To suit 016-013* 016-053
Phase angle To suit 016-014* 016-054
W atts To suit 016-015* 016-055
VA rs To suit 016-016* 016-056
VA To suit 016-017*
* Please state A or B at tim e of ordering. A = A N SI B = B S89
** C ustom er m ust state required scaling at tim e of ordering.
U L approved
71
Features
M easurem ent and indication of A C
am ps, volts, frequency and D C signals
Surface or w indow m ounting
R ear zero adjuster on m oving coil
m eters
H igh torque pivot and jew el m ovem ent
True R M S m easurem ent m eters
A C and D C inputs
U p to 40A D C direct connected
U p to 50A A C direct connected
Benefits
A C m oving iron and m oving coil
m echanism s
R educed inventory
4 A N SI standard case sizes
D etachable low er fascia plate
Easy to m odify for distributors
Through holes for back of panel
m ounting
Applications
M arine panels
Sw itchgear
D istribution system s
C ontrol panels
Em bedded generation
Energy m anagem ent
B uilding m anagem ent
U tility pow er m onitoring
Process control
M otor m onitoring
Compliant with
A N SI C 39.1 1981
IEC 51
U L3111-1
EM C
LVD
U L and C U L file no: E236986
Challenger Series
The C hallenger range of analogue panel m eters offers accurate
m easurem ent and indication of m ost electrical and electronic
param eters in industry standard 1
1
/2, 2
1
/2, 3
1
/2and 4
1
/2case sizes.
This innovative design features a detachable low er fascia plate, w hich
allow s the flexibility of either surface or w indow m ounting. The fascia is
sim ply unclipped to achieve the com pletely flush panel appearance of
rear of panel w indow m ounting.
The range offers A C and D C am m eters, voltm eters and frequency
m eters utilising a high torque pivot and jew el m ovem ent. A C m oving coil
rectified m eters provide 1.5% accuracy of the full scale value and feature
a rear zero adjuster screw for tam perproof installation. A C m oving iron
m eters also provide 1.5% high accuracy and true R M S m easurem ent.
Operation
The C hallenger series utilises a traditional pivot and jew el m ovem ent, incorporating
specially hardened steel pivots and a spring loaded jew el. This robust m echanism is
ideally suited for all applications, including the m ost dem anding conditions.
Moving Coil Meters
These m eters offer a centre cored, self-shielding m oving coil m ovem ent using pivots,
hairsprings and sprung jew els. Variations in m ovem ent are lim ited by design. A ll D C
voltm eters are 1000 ohm s per volt, m oving coil rectified products run at 900 ohm s per
volt. M illivolt m eters use a 5 m illiam ps/50m V m ovem ent.
Moving Iron Meters
This clapper type repulsion design utilises a pivot, hairspring and jew el m ovem ent.
The bottom jew el is oil filled to provide dam ping w hile the top is sprung for resilience.
A ll voltm eters are m anufactured w ith internal voltage dropper resistors.
Frequency Meters
Frequency m eters utilise a 1m A /35ohm D C m oving coil m ovem ent driven by an EM C
hard frequency conversion circuit.
Dials, Pointers and Scales
Standard dials are m att w hite w ith black printed scales and a tubular knife-edge black
m atte pointer. The 90 scales are balanced w ithin 1% of scale length and feature a
highly repeatable flattened arc scale shape, ensuring consistently accurate
m easurem ent readings. D ials are interchangeable betw een the C hallenger series for
inputs w ithin the published m eter specifications of the m eter. O ptions for non standard
custom ised dials are available upon request.
Current Transformers and Shunts
C rom pton Instrum ents, a B usiness U nit of Tyco Electronics, offers a com prehensive
range of current transform ers and shunts, for driving the C hallenger panel m eters for
the safe and sim ple m easurem ent of A C and D C currents.
O ur extensive range of current transform ers provides accurate m easurem ent of A C
current and ratio m atching to a consistent 5 or 1 am p secondary current, proportional to
the prim ary current.
O ur range of shunts ensures a D C m illivolt signal exactly proportional to the system current
for driving am m eters, providing accurate m easurem ent of D C current up to 12000A , w ith
secondary inputs of, 50, 60, 75 or 100m V D C to m atch the C hallenger input.
72
Specifications
Model 361 (1
1
/2")
Model 362 (2
1
/2")
Model 363 (3
1
/2")
Model 364 (4
1
/2")
Accuracy
D C am m eters and voltm eters 1.5% 0-100% of full scale deflection
A C am m eters and voltm eters M oving iron: 1.5% 10 -100% of full scale deflection
M oving coil: 1.5% 10-100% of full scale deflection
Frequency m eters 0.5% of end scale value
Input ratings
D C m oving coil am m eters 50A - 40A D C . (M odel 361: 10A m ax)
D C m oving coil voltm eters 50m V - 600V D C
D C m oving coil centre + /-50m A to + /-40A D C . (M odel 361: 10A m ax)
zero am m eters
D C m oving coil centre + /-50m V to + /-600V D C . Standard 1k ohm /volt
zero voltm eter
D C m oving coil suppressed 4/20m A D C
zero am m eters
D C m oving coil suppressed 1/5, 8/16, 16/32 or 12/24 V D C
zero voltm eters
A C m oving coil am m eters 100A - 750m A A C
A C m oving coil voltm eters 20 - 600V A C . Standard 900ohm s/volt
A C m oving iron am m eters 1 - 50A A C (M odel 361: non applicable)
A C m oving iron voltm eters 3 - 600V A C (M odel 361: non applicable)
Frequency 100/130V, 200/250V, 360/440V, 50H z, 60H z or 400H z
(M odel 361: non applicable)
B urden A m m eter 0.5VA Voltm eter: 4.5VA Frequency: 4VA
O verload 1.2 continuous x 10 for 0.5 seconds
Enclosure
M ovem ent H igh torque pivot and jew el m oving coil and m oving iron
Scale balance W ithin 1% of scale length
R elative hum idity 25% - 80% nom inal range of use
O perating tem perature 0C to 40C (-32F to 104F)
Storage tem perature -20C + 55C (-4F to 131F)
C ase and low er m ask B lack m atte case U L94V. Polycarbonate cover
W indow Shatterproof polycarbonate
Surface m ounting 4 corner studs
R ear of panel m ounting 2 through hole m ounts (M odel 361: facility pending)
Compliant with
U L and C U L 61010B -1 File no: E236986
Perform ance A N SI C 39.1 1981 and IEC 51
Scaling A N SI C 39.1 1981
Safety IEC 61010-1 (LVD ) and B S EN 61326:1998 (EM C )
Vibration A N SI C 39.1 1981 cl. 5.13
Input Model 361 Model 362 Model 363 Model 364
cat. no. cat. no. cat. no. cat. no.
D C m oving coil am ps 361-01A 362-01A 363-01A 364-01A
D C m oving coil volts 361-01V 362-01V 363-01V 364-01V
D C m oving coil centre 361-01C 362-01C 363-01C 364-01C
zero am ps
D C m oving coil centre 361-01N 362-01N 363-01N 364-01N
zero volts
D C m oving coil suppressed 361-01R 362-01R 363-01R 364-01R
zero am ps
D C m oving coil suppressed 361-01S 362-01S 363-01S 364-01S
zero volts
A C m oving coil am ps 361-01B 362-01B 363-01B 364-01B
A C m oving coil volts 361-01W 362-01W 363-01W 364-01W
A C m oving iron am ps N /A 362-02A 363-02A 364-02A
A C m oving iron volts N /A 362-02V 363-02V 364-02V
Frequency N /A 362-41S 363-41S 364-41S
Product Codes
Please specify current, voltage, frequency and required options at tim e of ordering.
73
Connections
DC Amps Self contained DC Amps For use with external shunt
DC Volts AC Amps Self contained
AC Amps For use with AC Volts
current transformer
Frequency Meter
74
Dimensions Surface Mount
Model 361
Model 362
Model 363
Model 364
75
Dimensions Panel Mount
Model 361
Surface Mount Cut-out Window Mount Cut-out
Model 362
Surface Mount Cut-out Window Mount Cut-out
Model 363
Surface Mount Cut-out Window Mount Cut-out
Model 364
Surface Mount Cut-out Window Mount Cut-out
76
Sealed and Ruggedised Indicators
078/080/087 Series 240 Scale
The C rom pton Instrum ents 078/080/ 087 series of heavy duty sealed
instrum ents are designed to com ply w ith the m ost stringent industrial,
m arine and m ilitary specifications.
This m etal cased range offers bezel sizes of 57m m , 83m m and 110m m
all fitted w ith toughened glass. Indicators com ply w ith M inistry of
D efence specification D EF STA N 66.7. and operate efficiently in the
m ost adverse environm ents w here extrem e conditions of shock,
vibration, dirt, hum idity and tem perature variation are present.
Description
Indicators have m etal cases w ith bezel sizes of 50 x 57m m (083), 83m m (084) and
110m m x 100m m (078/087). A ll indicators are fitted w ith toughened glass w indow s.
The standard black m atte finish can be replaced w ith options ranging from light
adm iralty grey to B S3181C N o:697. To prevent fogging, all indicators have been dried,
evacuated and filled w ith dry nitrogen during m anufacturing. The case interior retains a
constant pressure of at least 94kPa above the exterior w ith leakage not above the
equivalent of 1.33 Pa m l/s of air. Except on m odel 083, panel sealing gaskets are
standard equipm ent.
Standard instrum ent dials are finished in acrylic w hite m atte w ith black printing and a
parallel pointer. Scales form a true arc w ith zero on the left hand-side. O ptions include
dial illum ination, a centre, off-set or suppressed zero, colour index lines, bands, zones or
segm ents, a black dial w ith w hite printing, and custom er logo.
Features
D esigned specifically for stringent
industrial, m arine and m ilitary
specifications
A n extensive range of high accuracy
m easuring instrum ents in 3 case sizes
R ugged H i-Q taut-band suspension
B um p, shock and vibration proof
Benefits
C om plies w ith B S EN 60051 (IEC 51)
IP67 (N EM A 6 and 6P) protection
D ial illum ination option
Parallax error-free platform dials for
078/087. O ptional for 083/084
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
U tility pow er m onitoring
Process control
M otor control
M arine
M ilitary
Approvals
D EF STA N 66.7
Intrinsically safe options to EEx ia
11C T4
Specifications
Perform ance: B S EN 60051 (IEC 51)
D EF STA N 66-7 on request (087 only)
A ccuracy: R efer to Product R ange table
Scaling: B S89, B S3693 or D EF STA N 66-7 and 66-9
D ielectric test: 2kV r.m .s to B SEN 61010-1
O verloads: x 1.2 rated current for 2 hours
x 10 rated current for 5 seconds
x 1.2 rated voltage for 2 hours
x 2 rated voltage for 5 seconds
Enclosure code: IP67 (N EM A 6 and 6P)
C ase: B lack m atte m etal filled w ith dry nitrogen
B ezel: B lack m atte m etal. O ptional adm iralty grey N o. 697
B ezel w indow : Toughened glass
O perating tem p.: -40C to + 70C (-40F to + 158F)
Storage tem p: -55C to + 85C (-67F to 185F)
Standard calibration: 23C (73F)
A pprovals: EM C and LVD .
D EF 66.7
Intrinsically safe option to EEx ia 11C T4
77
Product Range 078/080/087 Series 240 Scale
Accuracy Burden Case code
Type of instrument Ranges class VA depth behind the bezel Product code
A C am m eter m oving iron 0.75-20A 2.5 2 57 - - - 083-03A
A C am m eter m oving iron 0.75-20A 1.5 2 - 59 - - 084-03A
A C am m eter m oving iron 0.5-30A 1.5 2 - - 86 - 078-08A
A C am m eter m oving iron 0.5-30A 1.5 2 - - - 86 087-08A
A C voltm eter m oving iron 5-800V 2.5 5 57 - - - 083-03V
A C voltm eter m oving iron 5-800V 1.5 5 - 59 - - 084-03V
A C voltm eter m oving iron 5-800V 1.5 5 - - 86 - 078-08V
A C voltm eter m oving iron 5-800V 1.0 5 - - - 86 087-08V
D C am m eter shunt operated 50, 60, 75, 100, 150m V 2.5 See T118*** 57 - - - 083-05A
D C am m eter shunt operated 50, 60, 75, 100, 150m V 1.5 See T118*** - 59 - - 084-05A
D C am m eter shunt operated 50, 60, 75, 100, 150m V 1.5 See T118*** - - 86 - 078-05A
D C am m eter shunt operated 50, 60, 75, 100, 150m V 1.5 See T118*** - - - 86 087-11A
D C am m eter 200A -30A 2.5 See T118*** 57 - - - 083-05A
D C am m eter 200A -30A 1.5 See T118*** - 59 - - 084-05A
D C am m eter 200A -30A 1.0 See T118*** - - 86 078-05A
D C am m eter 200A -30A 1.0 See T118*** - - - 86 087-11A
D C am m eter suppressed zero 4/20m A 2.5 See T118*** 57 - - - 083-05R
D C am m eter suppressed zero 4/20m A 1.5 See T118*** - 59 - - 084-05R
D C am m eter suppressed zero 4/20m A 1.5 See T118*** - - 86 - 078-05R
D C am m eter suppressed zero 4/20m A 1.5 See T118*** - - - 86 087-11R
D C voltm eter 50m V-600V 2.5 See T118*** 57 - - - 083-05V
D C voltm eter 50m V-600V 1.5 See T118*** - 59 - - 084-05V
D C voltm eter 50m V-800V 1.5 See T118*** - - 86 - 078-05V
D C voltm eter 50m V-800V 1.0 See T118*** - - - 86 087-11V
D C voltm eter suppressed zero 1/5V 1.5 See T118*** - - 86 - 078-05S
D C voltm eter suppressed zero 1/5V 1.5 See T118*** - - - 86 087-11S
A C rectified am m eter 200A -1A 2.5 See T118*** 57 - - - 083-05B
A C rectified am m eter 200A -1A 2.5 See T118*** - 59 - - 084-05B
A C rectified am m eter 200A -30A 1.5 See T118*** - - 86 - 078-05B
A C rectified am m eter 200A -30A 1.5 See T118*** - - - 86 087-11B
A C rectified voltm eter 15-600V 25H z/3kH z 2.5 See T118*** 57 - - - 083-05W
A C rectified voltm eter 15-600V 25H z/3kH z 2.5 See T118*** - 59 - - 084-05W
A C rectified voltm eter 15-600V 25H z/3kH z 1.5 See T118*** - - 86 - 078-05W
A C rectified voltm eter 15-600V 25H z/3kH z 1.5 See T118*** - - - 86 087-11W
Elapsed tim e m eter 50 or 60H z, 100-400V* 57 - - - 083-155 or 156
Elapsed tim e m eter 12, 24V D C 57 - - - 083-151
Elapsed tim e m eter 50 or 60H z, 100-400V* - 59 - - 084-155 or 156
Elapsed tim e m eter 12, 24V D C - 59 - - 084-151
Elapsed tim e m eter 50 or 60H z, 100-400V* - - 86 - 078-155 or 156
Frequency m eter 50/60/400H z 100-440V* 0.5% 4 57 - - - 083-41S
Frequency m eter 50/60/400H z 100-440V* 0.5% 4 - 59 - - 084-41S/089-41S
Frequency m eter 50/60/400H z 100-440V* 0.5% 4 - 86 86 078/087-41L
Tem perature indicator R TD 1.5 See T118*** - - 86 - 078-45 R
W attm eter or VA rm eter 0.2-10A /100-440V* B alanced C urrent - - 132 132 078/087-21 or 31
360 pow er factor m eter 1 or 5A 100-440V* 2 - - 132 132 078-13
50 or 60H z
360 pow er factor m eter 1 or 5A 100-440V* 2 - - 132 132 087-13
50, 60 or 400H z
360 rotary synchroscope 100/125V, 200/250 2 - - 132 132 078/087-14
380/450**
Transducer operated indicator 1, 5, 10, 20 or 4/20m A 1.0 See T118*** 57 - - - 083-05
Transducer operated indicator 1, 5, 10, 20 or 4/20m A 1.0 See T118*** - 59 - - 084-05
Transducer operated indicator 1, 5, 10, 20 or 4/20m A 1.0 See T118*** - - 86 - 078-05
Transducer operated indicator 1, 5, 10, 20 or 4/20m A 1.0 See T118*** - - - 86 087-11
* 100-440V = (100/125, 200/250, 380/440) ** U sing transform er box 855-954.
*** The T118 technical sheet is available on request. For specification and connection diagram s, please refer to equivalent
m odels in the 240 Series D IN Panel M eter section. R eplace 244 w ith
078 etc., e.g. 244-210 becom es 078-210.
78
Features
D esigned specifically for stringent
industrial, m arine and m ilitary
specifications
A n extensive range of high accuracy
m easuring instrum ents in 5 case sizes
R ugged H i-Q taut-band suspension
B um p, shock and vibration proof
Benefits
C om plies w ith B S EN 60051 (IEC 51)
for m odels 081 to 084
IP67 (N EM A 6 and 6P) protection for
m odels 083/084 and 089
IP68 for m odels 081 and 082
D ial illum ination options
Applications
Sw itchgear
D istribution system s
G enerator sets
C ontrol panels
Energy m anagem ent
U tility pow er m onitoring
Process control
M otor control
Industrial, m arine and m ilitary
specifications
Approvals
D EF STA N 66.7 and 66.9
(M odels 081, 084 and 089)
Specifications
Sealed and Ruggedised Indicators
080 Series 90 Scale
A range of m etal case, sealed instrum ents for industrial and m ilitary
applications involving extrem e shock, vibration, tem perature, dirtand
hum idity. B ezel sizes 32m m , 45m m , 57m m , 83m m com ply w ith M inistry
of D efence specification D EF STA N 66-7 or D EF STA N 66-9 forall
standard ratings. B ezel size 89m m com plies w ith M IL-M -10304
dim ensions.
Description
Five bezel sizes of 32m m (081), 45m m (082), 57 x 57m m (083), 83m m (084) and
89m m (089) w ith barrel diam eters of 26m m (081), 37m m (082), 53m m (083), and
67m m (084 and 089) and toughened glass w indow s are used throughout the series.
To avoid fogging they are dried, evacuated and filled w ith dry nitrogen. Panel sealing
gaskets are provided as standard w ith the exception of M odel 083. The sm aller cases
on M odels 081 and 082, are m ade from nickel-plated brass and anodised alum inium
alloy. Single hole fixing is m ade w ith threaded clam p ring w hich screw s onto the barrel,
they also have ceram ic insulated term inals and no zero adjuster is fitted. M odels 083,
084 and 089 have steel cases w ith fixing holes in the flange. Sealed zero adjusters are
provided. Standard instrum ent dials are finished in a w hite m atte w ith black printing and
parallel pointer. The scales form a true arc w ith zero on the left.
Options
A vailable options include dial illum ination, a centre, off-set or suppressed zero, colour
index lines, bands, zones or segm ents, a black dial w ith w hite printing and custom er
logo. Instrum ents operated by separate transducers indicate w atts, VA r, frequency,
phase angle, current, voltage and other physical/m echanical param eters are also
available. Illum ination options as follow s:
M odel 081: Through-dial, w hite or red bulb, 12 or 24V illum ination.
M odels 081/082: B etalite through-dial, 12 or 24V, illum ination.
M odels 082/083/084/089: Through-dial, red or clear LED , 12 or 24V illum ination.
M odels 083/084/089: Edge, w hite or red bulb, 12 or 24V, illum ination.
Perform ance: B S EN 60051 (IEC 51) for m odels 081 to 084
D EF STA N 66-7 and 66.9 on request (081/084 and 089)
A ccuracy: M odel 081: C lass 5. O thers: C lass 2.5
Frequency m eter 0.5% of m id frequency (083, 084, 089)
Scaling: To B S89, B S3693 or D EF STA N 66-7 and 66-9 (081
to 084)
D ielectric test @ 50 H z: 750V R M S (081); 1kV R M S (082);
2kV R M S (083/084/089); < 50V 500V R M S
A ll for 1 m inute
O verloads: x 1.2 rated current or voltage for 2 hours
x 10 rated current for 5 seconds
x 2 rated voltage for 5 seconds
B urden: A C am m eter: 1VA m axim um
A C voltm eter: 3VA m axim um
Frequency m eter: 4VA m axim um
Elapsed tim e m eter: 2.5VA m axim um
Enclosure code : 083/084/089: to IP67 (N EM A 6 and 6P)
081/082: to IP68
C ase: 081/084 and 089: B lack m atte m etal filled w ith dry nitrogen
081 and 082: N ickel-plated brass and anodised
alum inium alloy.
B ezel: B lack m atte m etal
B ezel w indow : Toughened glass
O perating tem p:. M odel 081 to 084: -40C to + 70C (-45F to + 158F)
M odel 089: -55C to 65C (-67F to + 185F)
Standard calibration: 23C (73F)
A pprovals: EM C and LVD .
D EF 66.7 and 66.9
79
Product Range 080 Series 90 Scale
Case code
Type of instrument Ranges 081 082 083 084 089 Product code
A C am m eter m oving iron 1-30A 3 083-75A
A C am m eter m oving iron 1-30A 3 084-75A
A C am m eter m oving iron 1-30A 3 089-75A
A C voltm eter m oving iron 5-300V 3 083-75V
A C voltm eter m oving iron 5-500V 3 084-75V
A C voltm eter m oving iron 5-500V 3 089-75V
D C am m eter shunt operated 50, 60, 75, 100, 150m V 3 081-80A
D C am m eter shunt operated 50, 60, 75, 100, 150m V 3 082-80A
D C am m eter shunt operated 50, 60, 75, 100, 150m V 3 083-80A
D C am m eter shunt operated 50, 60, 75, 100, 150m V 3 084-80A
D C am m eter shunt operated 50, 60, 75, 100, 150m V - 3 089-80A
D C am m eter 50A -20m A 3 081-80A
D C am m eter 50A -10A 3 082-80A
D C am m eter 50A -30A 3 083-80A
D C am m eter 50A -30A 3 084-80A
D C am m eter 50A -30A 3 089-80A
D C am m eter suppressed zero 4/20m A 3 - 081-80R
D C am m eter suppressed zero 4/20m A 3 082-80R
D C am m eter suppressed zero 4/20m A 3 083-80R
D C am m eter suppressed zero 4/20m A 3 084-80R
D C voltm eter 50m V-300V 3 081-80V
D C voltm eter 50m V-300V 3 082-80V
D C voltm eter 50m V-300V, 1000/V 3 083-80V
D C voltm eter 50m V-300V 3 084-80V
D C voltm eter 50m V-300V 3 089-80V
D C voltm eter suppressed zero 1/5V 3 082-80S
D C voltm eter suppressed zero 1/5V 3 084-80S
A C rectified am m eter 100A -500m A .25H z/3kH z 3 082-80B
A C rectified am m eter 100A -500m A .25H z/3kH z 3 083-80B
A C rectified am m eter 100A -500m A .25H z/3kH z 3 084-80B
A C rectified voltm eter 15-300V 3 082-80W
A C rectified voltm eter 15-600V, 900/V 3 083-80W
A C rectified voltm eter 15-600V 3 084-80W
A C rectified voltm eter 15-600V 3 089-80W
Elapsed tim e m eter (99999.9) 12 or 24V D C 3 3 3 082/083/084-151
Elapsed tim e m eter (99999.9) 50H z / 100-440V* 3 3 083/084-155
Elapsed tim e m eter (99999.9) 60H z / 100-440V* 3 3 083/084-156
Elapsed tim e m eter (99999.9) 50H z / 100-440V* 3 089-155
Elapsed tim e m eter (99999.9) 60H z / 100-440V* 3 089-156
Frequency m eter 50 or 60 or 400H z/100-440V* 3 083-41S
Frequency m eter 50 or 60 or 400H z/100-440V* 3 084-41S
Frequency m eter 50 or 60 or 400H z/100-440V* 3 089-41S
Transducer indicator speed 1, 5, 10, 20, and 4/20m A 3 084/802
Transducer indicator frequency 1, 5, 10, 20, and 4/20m A 3 084/803
Transducer indicator phase angle 1, 5, 10, 20, and 4/20m A 3 084/804
Transducer indicator w atts 1, 5, 10, 20, and 4/20m A 3 084/805
Transducer indicator VA rs 1, 5, 10, 20, and 4/20m A 3 084/806
Transducer indicator VA 1, 5, 10, 20, and 4/20m A 3 084/807
*100-440V (100/125 or 200/250 or 380/440)
80
Dimensions
Model 081
Model 082
Model 083
Model 084/089
A B C D E F G H
084-80 35 33.5 59 82.5 20 5 36.5 6 off
089-80 35 33.5 59 88.9 20 5 36.5 3 off
084-75 35 38 64 82.5 20 5 36.5 6 off
089-75 35 38 64 88.9 20 5 36.5 3 off
Panel C ut out 68.3 H oles 3.8
These holes on 084 only.
81
Catalogue Numbering System
Guide to Catalogue Numbering System Example Code: 244 03AG LSPK C6 ER
MOVEMENT CODE
01 Short-scale A C and D C
02 Short-scale A C
03 Long-scale A C and D C
05 Long-scale A C and D C
07 Edgew ise A C D C
08 Long-scale A C
10 Edgew ise A C and D C
11 Long-scale D C
12 Phase sequence m eter
13 360 rotating iron PFI
14 Synchroscope
15 Elapsed tim e m eter
16 Therm al dem and
am m eter
21 W attm eter
30 M eter relay
31 VA rm eter
41L Frequency m eter
long-scale
41S Frequency m eter
short-scale
42 Pow er factor m eter
45 R TD tem perature
92 Shunts
94 C urrent transform ers
H W Kilow att hour class 1.0
KH Kilow att hours
KW Kilow att hours class 2.0
TYPE / FUNCTION
A A m peres D C
B R ectified am peres
C C enter zero am ps
D Zero offset current
F A m peres A C
G Volts A C
H H igh m iddle
K D C input non electrical
scaling
L VA r self contained
N C enter zero voltage
P Zero offset voltage
R Live zero current
S Live zero voltage
V Volts D C
W R ectified voltage
Y Expanded scale A C
Z Expanded scale D C
2 2 x overload am m eters
3 3 x overload am m eters
5 1-phase 2-w ire w atts
6 6 x overload am m eters
8 3-phase 3-w ire w atts
9 3-phase 4-w ire w atts
NATIONAL STANDARD
A A N SI C 39.1
B B S 89
G D IN
I A N SI fixing captions
J Japanese instrum ent
Standard
INPUT OR
MOVEMENT RATING
LA 1A
LS 5A
PZ 150V
R X 300V
SJ 600V
PN 120V
R P 240V
SE 480V
Q Q 120V 5A
Q S 240V 5A
Q T 480V 5A etc
SCALING OR OUTPUT
B X Volt free relay contacts
FA 1m A
H G 4/20m A
PK 0/100
PZ 0/150
R L 0/200
R X 0/300
SC 0/400
SJ 0/600
SS 0/1000
TM 0/2000
U B 0/4000
U J 0/5000 etc
SYSTEM
FREQUENCY
(A C M eters)
C 4 400H z
C 5 50H z
C 6 60H z
C 7 50/60H z
ER 244 03 A G LS PK C6
This guide is not inclusive of all catalogue num bers and should be
used for reference only, as im proper com binations can be achieved.
SERIES
016 Fiesta
075 Short-case sw itchboard
077 Standard sw itchboard
078 H i-shock sealed
079 8
3
/4" sw itchboard
083 2" sealed
084 2
1
/2" sealed
242 48m m D IN
243 72m m D IN
244 96m D IN
246 144m m D IN
E242 48m m short-scale
E243 72m m short-scale
E244 96m m short-scale
OPTIONS
Indicate as
required
82
Glossary
Glossary of Terms
MI M oving iron, also called iron vanein the N orth A m erican m arket for m easuring A C am ps and volts.
MC M oving coil for m easuring D C am ps and volts.
Taut band suspension A m eter m ovem ent held under tension, usually on a ligam ent.
movement
Ligament The taut band.
Pivot and jewell (P&J ) A m ovem ent w hich rotates on a spindle, and pivots w ithin an oil filled jew el. This type of m ovem ent
typically offers excellent vibration resistance characteristics.
Short-scale A ngle of deflection for a m ovem ent is usually 90 degrees but A N SI is 100 degrees in som e products.
Long-scale A ngle of deflection for a m ovem ent is usually 240 degrees but is frequently referred to as 270 degree.
FSD Full scale deflection.
ES End scale.
Input Electrical value from w hich the m easurem ent is derived to achieve the full scale deflection of
the m ovem ent.
Linear A term used to state that the input is constant, allow ing for an even scaling.
Non linear The opposite of linear, giving a scale shape w hich w ill cram p at som e point on the dial. U sually
inaccurate below 20% of the full-scale value.
Logarithmic scaling A log scale usually derived from a non linear D C output.
Scale The graphical representation of the value being m easured.
Dual arc M ore than one set of figures on a dial plate.
Dial plate/scale plate Surface on w hich the dial is draw n.
Calibration chart A chart m atching input values to scale m ark, m ainly used for com plicated scales.
Enclosure rating U sually expressed in the form of IP rating or as N EM A in A m erica. This states the product,
resistance to the ingress of m oisture and dust.
DIN European standard m eter shape. It is based on m ultiplies of 24m m , i.e. 48, 72, 96, 144 m m .
ANSI A m erican N ational Instrum ent Standard.
J IS Japanese Instrum ent Standard.
BS89 O ld B ritish Standard usually refers to rectangular m eter or Fiestastyle products.
Switchboard meter G eneral term for long-scale instrum ents.
Panel meter G eneral nam e for short-scale instrum ents.
Analogue indicator G eneric term for instrum ents usually refers to a low accuracy m eter. A n indicator only.
Tyco Electronics C I-EPP-U K-A N A LO G U E-11/09
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding
and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the
suitability of each product for the desired application. Under no circumstances does this constitute an assurance of
any particular quality or performance. Such an assurance is only provided in the context of our product specifications
or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions
of sale. Paladin and CROMPTON are trademarks of Crompton Parkinson Ltd. and is used by Tyco Electronics
under licence.
Energy Products economical solutions for the electrical power industry: cable
accessories, connectors & fittings, electrical equipment, instruments, lighting
controls, insulators & insulation enhancement and surge arresters.
Tyco Electronics U K Lim ited, C rom pton Instrum ents
Freebournes R oad, W itham , Essex, C M 8 3A H , U K
Phone: + + 44 (0)870 870 7500
Fax: + + 44 (0)870 240 5287
w w w .tycoelectronics.com
a vital part of your w orld