You are on page 1of 10

abcd

INSTALLATION AND USER'S GUIDE


WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
1/1
S900
MANUAL
The recipient is responsible for destroying obsolete issues.
02 98-07 DO-Monjean SAF-Vacassin
01 97-07 SAM-Schuler SAM-Vacassin
ED DATE APPROVED BY ORIGINATED BY
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
2/2
TABLE OF CONTENTS
1 INTRODUCTION........................................................................................................................4
1.1 ABOUT THIS MANUAL........................................................................................................4
1.2 APPLICABILITY.....................................................................................................................4
1.3 WHO SHOULD READ THIS MANUAL...................................................................................4
1.4 RELATED PUBLICATION.......................................................................................................4
2 GENERAL PRESENTATION.........................................................................................................5
2.1 SOFTWARE OVERWIEW.......................................................................................................5
2.2 SOFTWARE FUNCTIONS......................................................................................................5
3 SOFTWARE INSTALLATION........................................................................................................6
3.1 HARDWARE AND SOFTWARE REQUIREMENTS....................................................................6
3.2 DISKETTE PROVIDED WITH THE SOFTWARE.......................................................................6
3.3 INSTALLATION PROCEDURE...............................................................................................6
3.4 WLD 900 CONFIGURATION AND SETTING.........................................................................6
3.5 WLD 900 UNINSTALLATION ...............................................................................................7
4 USER'S GUIDE............................................................................................................................8
4.1 BEFORE A DOWNLOADING...............................................................................................8
4.2 FILE LOADING IN THE PC...................................................................................................8
4.2.1 S900 RTU program file.............................................................................................................. 8
4.2.2 S900 Data Base files................................................................................................................. 8
4.3 DOWNLOADING PROCEDURE............................................................................................9
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
3/3
DOCUMENT CHANGE RECORD
Ed. Date Description of modification
00 97-07-03 Creation
01 97-07-09 First issue
02 98-07-01 Installation from a CD ROM - DE 1523
PROBLEMS, QUESTIONS AND SUGGESTIONS
If you have any problems with the software or hardware, or require troubleshooting information, please
contact the After-sales support department for assistance:
ALSTOM T&D CETT SA
Service aprs-vente
3, parc des Grillons
60, route de Sartrouville
78230 LE PECQ - FRANCE
Tel : 01.34.80.79.00
Fax : 01. 34.80.79.99
TRADEMARKS AND COPYRIGHT NOTICE
Windows 95 is a registered trademark of MICROSOFT Corporation
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
4/4
1 INTRODUCTION
1.1 ABOUT THIS MANUAL
This manual describes how install , configure and use the Winload 900 ( WLD 900 ) sofware associated to the
S900 RTU.
1.2 APPLICABILITY
The WLD 900 is designed for downloading the RTU S900 application program and Data Base from a PC to
the RTU, in Off-line mode.
The WLD 900 runs under Windows 95 oprating system.
1.3 WHO SHOULD READ THIS MANUAL
This manual is primarily intended for operators responsible for the sofware maintenance of the RTU.
1.4 RELATED PUBLICATION
Tis document should be used in conjunction with the following CETT technical references:
S900 RTU Installation Guide 45 180 001-631 A
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
5/5
2 GENERAL PRESENTATION
2.1 SOFTWARE OVERWIEW
The Winload 900, installed on a PC, is design to download files to the S900 RTU.
These files, are SRecord formated and must be the application program of the S900 file or the DB file.
WLD 900 only offers the Off line mode of downloading .
2.2 SOFTWARE FUNCTIONS
This WLD 900 sofware offers the following facilities:
- a simplified install under Windows 95;
- a Windows 95 man machine interface;
- the choice between the port COM 1 or COM 2;
- the PC serial port setting depending on S900 setting;
- a direct selection of the daownloaded file under Windows Explorer;
- a direct display of the remaining time for the downloading operation.
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
6/6
3 SOFTWARE INSTALLATION
3.1 HARDWARE AND SOFTWARE REQUIREMENTS
The WLD 900 requires this minimum configuration:
- CPU Pentium;
- 8 Mb RAM.
The PC must run the english version of Windows 95.
3.2 DISKETTE OR CD ROM PROVIDED WITH THE SOFTWARE
Two cases::
1st : The S900 software version is HB
The WLD 900 is supplied on a 3.5 Inch, 1.44 Mb diskette labeled
WINLOAD 900 - 45 180 114 - and version , including :
- the install program
- the WLD 900 downloading program
2nd : The S900 software version is J A or J B
The WLD 900 is included in the S900 CD ROM
3.3 INSTALLATION PROCEDURE
1st case : WLD on diskette
The WLD 900 installation is automaticaly done under Windows 95 using the following procedure:
- insert the delivered diskette in the drive A:
- under Windows explorer, call the SETUP.EXE file on the drive A:
- follow the given instructions on the screen
- move the Winload900.PIF icon from the C:\Program files\CETT\Winload900 directory to the DESK TOP
directory;
Warning ! note that the .PIF files have no extention name under Windows explorer
- when complete, the Winload 900 icon appears on the desk.
2nd case : WLD on CD ROM
Follow the installation procedure describe in the README.TXT file included in the CD ROM
3.4 WLD 900 CONFIGURATION AND SETTING
The WLD 900 configuration is limited to the communication port setting.
It depend on the S900 setting and the boot program version of the CPU 900 board ( EPROM located on the
EMS 901 daughter board).
Under Windows 95 desk, process as follow:
- clic the Winload 900 icon, the Winload 900 windows appears;
- choose the coms port COM1 or 2;
- clic on the Configure button, the Port Settings windows appears;
- choose the parameters value as follow :
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
7/7
- speed : - 9600 bps if the CPU 900 EPROM version is < DA
- 38400 bps if the CPU 900 EPROM version is DA
- others : 8 bits, parity none, 1 stop bit, none flow control;
- hit the Enter key and quit.
3.5 WLD 900 UNINSTALLATION
If you want to uninstall WLD 900 or install a new version you must uninstall the actual version, as follow:
- under Windows 95, call the Add/Remove programs facility of the Control Panel windows in the Settings
menu;
- in the Add/Remove windows, select the Winload 900 file ;
- choose the Remove operation and hit Enter.
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
8/8
4 USER'S GUIDE
4.1 BEFORE A DOWNLOADING
The file downloading from the PC needs particular operations on the S900 RTU described in the S900
Installation Guide.
Remember : the dowloading from the WLD 900 is only possible in Off line mode.
First, connect the Off line downloading cable ( CAB 941- ref. 45 180 428 ) at the PC end, on COM1 (or 2)
and at the CPU 900 end, on the J 3 port.
Make sure that the CPU port speed is the same than the PC one.
4.2 FILE LOADING IN THE PC
Remember : the downloaded file must be of SRecord format ( file with HEX extension ).
4.2.1 S900 RTU program file
The application program file must be first loaded in the PC, as follow:
- under Windows 95, call Windows Explorer;
- creat a directory labeled " Application " for example;
- two cases :
1- If the RTU S900 software is delivered on diskette,insert the diskette labeled " RTU S900 - application"
in the drive A:
. copy the S900 application file <XXX.EXE>( e.g. Ap_rtua4.EXE ) from the drive A: to the
"Application" directory
2- if the RTU S900 sofware is included on the CD ROM, follow the installation procedure described in
the README.TXT file on the CD ROM
- run this file ( double clic ) in order to create the SRecord format of this file.
- verify that the < XXX.HEX> file now exist in the same directory.
This file is the application program which will be downloaded in the S900 RTU.
4.2.2 S900 Data Base files
These files have been first directly created in SRecord format under GBD 900, the Data Base Generator.
We just have to process as follow, under Windows Explorer :
- Two cases :
1- the GBD 900 is implemented in the same PC than WLD 900
No operation is necessary because, DB files are already on the hard disk, under the
C:\GBD_S900\TESTS\EXE directory.
Note: The name of the DB file for the RTU Nr 03 is BD_PC3.HEX
2- the DB files previously generated on another PC are available on diskette(s)
. insert the diskette with DB files in the drive A:
. copy the files <YYY.HEX> from the drive A: to the " Application " directory ( or other if you want )
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
9/9
4.3 DOWNLOADING PROCEDURE
Now you can download the files in the S900 RTU with the following procedure :
- from the windows 95 desk, clic the Winload 900 icon, the Winload 900 windows appears;
- choose the coms port COM1 ( or 2 );
- verify that the coms parameters are OK, if not, go to the paragraph 3.4 and back to the following step;
- clic the Upload button, the windows " Open " appears;
- search the file to be download in the correct directory ( see the paragraph 4.2 );
- double clic the found file name to process the downloading of this file;
- after a few second the remaining time before complete and the speed appear;
Note: The speed showed during the downloading is the real number of byte transmitted per second
- follow the downloading processing on the bar-graph;
- when complete the remaining time is null;
- verify on the S900 if the dowloading is complete ( refer to the S900 installation guide ).
abcd
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
ED 02 98-07-01
CETT
45 180 040-630-4 A
Communication, reproduction, utilisation interdites sauf autorisation crite
1/1
Responsable et rdacteurs
SAF-Vacassin
INSTALLATION AND USER'S GUIDE
WINLOAD 900
S900
Rubrique : S900
Type : MANUAL
Code diffusion Interne : 0079
Vrification
Nom
Visa
SAP-Fargette SAP-Juin
Nom
Visa
HISTORIQUE
Ed.It Date Motif de la modification
00 97-07-03 Cration
0.01 97-07-03 Mise en relecture
01 97-07-09 Premire diffusion
02 98-07-01 Installation partir d'un CD ROM - DE 1523
REFERENCES DOCUMENTAIRES
Sans objet
INFORMATIONS A USAGE INTERNE
Edition du 18/ 12/ 96
1 - Pour mettre jour les informations de gestion, lancer la macro UpDateInfo.
NE PAS MODIFIER LES CHAMPS DU DOCUMENT OU DES PIEDS DE PAGE.
2 - Suite ce qui semble tre un bug de Word, la fmi est en fin de document, et le nombre de pages est
en dur et non automatique. Le modifier si une 2 page fmi est cre.
3 - Tables des matires : Faire Options et enter 1 en face de Annexe1.

You might also like