M Family Voltage/Frequency Relay

Three-phase and ground


voltage protection relay.

Features and Benefits

Advanced 16-bit microprocessor

Configurable logic, curves, digital I/Os,


and LEDs

Applications

Voltage and/or frequency protection at any


voltage in automatic transfer systems,
generators, motors, lines and busbars

Flash memory for field upgrades

enerVista.com compatible (see page 275)

Two settings groups

Protection and Control

Three models available for voltage,


frequency and combined protection

Three-phase over and undervoltage,


ground overvoltage

Drawout case for easy maintenance

AC/DC power supply

Voltage unbalance, over and


underfrequency

Access via front panel keypad or


communication links

Monitoring and Metering

Diagnostic features event recording


and analog/digital oscillography

User Interfaces

Compatible with M Family systems in


half or full 19" racks

Frequency and per-phase voltage

M+PC software for setting and


monitoring

Front RS232 and rear RS485 ports using


ModBus RTU protocol up to 19,200 bps

GE Multilin

MIV M Family Voltage/Frequency Relay

Protection
The MIV, a member of the M
Family, is a digital device that
provides voltage and frequency
protection for a wide range of
applications at any voltage level:
NOTE: The MIV1000 includes voltage functions, the MIV2000
includes frequency functions (four
units), and the MIV3000 includes
both voltage and frequency (two)
units.
Phase Overvoltage

Ground Overvoltage
Two separately adjustable ground
overvoltage units can be independently enabled. The pickup
setpoint can be set from 2 to
250 V depending on the model
and a time delay from 0 to 600
seconds.
Voltage Unbalance

Two separately adjustable phase


overvoltage units can be independently enabled. The pickup setpoint can be set from 2 to 250 V
depending on the model, and a
time delay from 0 to 600 seconds.
The protection units operate on
phase-to-phase or phase-toground voltage magnitudes.
Phase Undervoltage
This function has the same settings
and features as the phase overvoltage protection. To avoid
permanent undervoltage tripping
when a breaker is open and the VTs

are located on the line side, a


setting is provided to enable/
disable undervoltage protection
units.

This function operates on negative sequence voltage, and is


included in the MIV 3000 relay.
Pickup and time delay settings are
the same as those of voltage
functions.

Configurable Logic
Up to four configurable logic
schemes can be implemented via
four pre-configured logic gates and
timer cells. A graphical user interface provides easy configuration.
The configurable logic output can
be used to configure digital
outputs and LEDs.

MIV Guideform
Specifications
For an electronic version of the MIV
guideform specifications, please
visit: www.GEindustrial.com/
Multilin/specs, fax your request
to 905-201-2098 or email to
literature.multilin@indsys.ge.com.

Frequency Functions
Depending on the model, either
two or four independent definite
time frequency units are provided.
Each unit can be independently
set as over and underfrequency,
and is supervised by an independently adjustable undervoltage
element.

Functional Block Diagram


BUS
52

2x27 2x59 2x59N 2x81O/


81U

LOAD

47

MIV 3000
743751A1.ai

www.GEindustrial.com/Multilin

MIV M Family Voltage/Frequency Relay

Typical Wiring
OPEN DELTA VT CONNECTION
A

B1 B2 B3 B4 A3 A4
VI

SINGLE PHASE VT CONNECTION

DIRECTION OF TRIP

N VII N VIII N

NOTE: 14 AWG wiring


recommended
AC
or
DC

B
C

B1 B2 B3 B4 A3 A4

A1

A2

VI

+/L

-/N

N VII N VIII N

B1 B2 B3 B4 A3 A4
VI

N VII N VIII N

POWER

A6

CAUTION: Fork or ring terminals must be used on the


termainal block.
NOTE: Suitable disconnect devices (switch or circuit
breaker) recommended located near the relay.
OVERVOLTAGE CATEGORY: II
(*) Terminals B12, A12 and B11 must be connected to
SELV (safety extra-lowvoltage) parts (on the PLC).
They are not to be tested for hipot test under any
circumstance.
(**)The default configuration of inputs and outputs
is as follows:
INPUTS
CC1: Block unit 78
CC2: Block voltage
functions
OUTPUTS
OUT1: 78 Trip
OUT2: 59/27 Trip
OUT3:59N Trip
OUT4: 81 Trip
GROUND
BUS

B5
B6

MIV
M-Family
Voltage/Frequency
Relay

A8 CC1
A9 CC2
A10 COM
RS232

VOLTAGE INPUTS

SDA B12(*)

SDB A12(*)

GND B11(*)

JX

SAFETY
GND GROUND

COM OUT4 OUT3 OUT1/2 OUT1

A5

RS485

>>

DIGITAL
INTPUTS(**)

TRIP
COIL

<<

TRIP

TRIP COIL CONTROL


POWER +

GE Multilin

52a

READY

52a

Internally fused
1A/250V fast blow

DIGITAL OUTPUTS(**)

VOLTAGE INPUTS

VOLTAGE INPUTS

GROUND

PROGRAMMABLE
CONTROLLER

B7

INPUT

B8

WYE-BROKEN-DELTA
VT CONNECTION

INPUT

A
B
C

B9
B10

B1 B2 B3 B4 A3 A4
VI

N VII N VIII N

A7

743750a4.ai

VOLTAGE INPUTS

Ordering
MIV

* 0 *

0E000 * 00 *

MIV
1
2
3
0
1
F
H
C
S

Voltage/frequency relay
Voltage functions
Frequency functions
Voltage + frequency functions
10 250 V setting range
2 60 V setting range
24 48 VDC auxiliary voltage
110 250 VDC 110 230 VAC auxiliary voltage
Individual relay
Mounted in an M+ system

If relays are to be mounted in an M+ system either an M050 half 19" rack or M100 full 19" rack case must be ordered. The M050 and M100 racks are provided at no additional cost.

Accessories
B1315P2

Depth reducing collar

enerVista enabled

See page 275.

www.enerVista.com

www.GEindustrial.com/Multilin