SO CF, Internal Fault Map Class 1A

Fault No Fault type


0
1 Reset, Power On
2 Reset, Switch
3 Reset, Watchdog
4 Reset, SW Fault
5 Reset, RAM Fault
6 Reset, Internal Function Change
7 XBus Fault
8 Timing Unit VCO Fault
9 Timing Bus Fault
10 Indoor Temp Out of Safe Range
11
12 DC Voltage Out Of Range
13
14 Bus Fault
15 RBS Data Base Corrupted
16 RU Data Base Corrupted
17 HW And IDB Inconsistent
18 Internal Configuration Failed
19 Indoor Temp Above Safe Range
20 Indoor Temp Below Safe Range
21 HW Fault
22 Air Time Counter Lost
23 Time Distribution Fault
.
47

SO CF, Internal Fault Map Class 2A


Fault No Fault Type
0
1 Reset, Power On
2 Reset, Switch
3 Reset, Watchdog
4 Reset, SW Fault
5 Reset, RAM Fault
6 Reset, Internal Function Change
7 RXDA Amplifier Current Fault
8 VSWR Limits Exceeded
9 Power Limits Exceeded
10 DXUOpt EEPROM Checksum Fault
11
12 RX Maxgain/Mingain Violated
13 Timing Unit VCO Ageing
14 CDU Supervision/Communication Lost
15 VSWR/Output Power Supervision Lost
16 Indoor Temp Out Of Normal Conditional Range
17 Indoor Humidity
18 DC Voltage Out Of Range
19 Power System in Standalone Mode
20
21 Internal Power Capacity Reduced
22 Battery Backup Capacity Reduced
23 Climate Capacity Reduced
24 HW Fault
25 Loadfile Missing in DXU or ECU
26 Climate Sensor Fault
27 System Voltage Sensor Fault
28 A/D Converter Fault
29 Over Voltage Protection/Varistor Fault
30 Bus Fault
31 High Frequency Software Fault
32 NonVolatile Memory Corrupted
33 RX Diversity Lost
34 Output Voltage Fault
35 Optional Synchronization Source
36 RU Data Base Corrupted
37 Circuit Breaker Tripped
38 Default Values Used
39 RX Cable Disconnected
40 Reset, DXU Link Lost
41 Lost communication to TRU
42 Lost communication to ECU

SO CF, External Condition Map Class 1B


Fault No Fault Type
0
1
2
3
4 L/R SWI (BTS In Local Mode)
5 L/R TI (Local to Remote while Link Lost)
6
7
8
9
10
11
12
13
14
15
SO CF, External Condition Map Class 2B
Fault No Fault Type
0
1
2
3
4
5
6
7
8
9 RBS DOOR (RBS cabinet door open)
10 MAINS FAIL (External power source fail)
11 ALNA/TMA Fault
12 ALNA/TMA Degraded
13 Auxiliary Equipment Fault
14 Battery Backup External Fuse Fault
15

43 Internal Configuration Failed


44 ESB Distribution Failure
45 High Temperature
46 DB parameter fault
47 Antenna Hopping Failure
48 GPS Synch Fault
49 Battery Backup time shorter than expected
50 RBS running on battery
51 TMA Supervision/Communications Lost
52 CXU Supervision/Communication Lost
53 HW and IDB Inconsistent
57 RX PATH IMBALANCE (cehck the antinna)

REP UNIT SO CF
0 DXU
1 ECU
2 MICRO RBS
3 Y LINK
4 SCU
5 CDU
6 CCU
7 PSU
8 SCU TO CDU PFWD PREF CABLE
9 BDM or BFU
10 ACCU
11 ACTIVE COOLER
12 ALNA/TMA A
13 ALNA/TMA B
14 BATTERY
15 FAN
16 HEATER
17 HEATER EXCHANGER EXT FAN
18 HEATER EXCHANGER INT FAN
19 HUMIDITY SENSOR
20 TMA CM
21 TEMPERATURE SENSOR
22 CDU HLOUT HLIN CABLE
23 CDU RX IN CABLE
24 CU
25 DU
26 FU
27 FU CU PFWD CABLE or CDU CDU PFWD CABLE
28 FU CU PREFL CABLE or CDU CDU PREFL CABLE
29 CAB HLIN CABLE
30 CDU BUS
31 ENVIRONMENT
32 LOCAL BUS
33 EPC BUS / POWER COMMUNICATION LOOP
34 RBS DB
35 EOM BUS
36 TIMING BUS
37 CDU CXU RXA CABLE
38 CDU CXU RXB CABLE
39 XBUS
40 ANTENNA
41 PSU DC CABLE
42 CXU DC CABLE
43 FLASH CARD

44 PTU
45 BATTERY TEMP SENSOR
46 FCU
47 OVPU
48 GPS RECEIVER or LMU
49 GPS RECEIVER DXU CABLE
50 ACTIVE COOLER FAN
51 BFU Fuse or Circuit Breaker
52 CDU CDU PFWD CABLE
53 CDU CDU PREFL CABLE
54 IOM BUS
55 ASU RXA UNITS OR CABLES
56 ASU RXB UNITS OR CABLES
57 ASU CDU RXA CABLE
58 ASU CDU RXB CABLE

SO TRXC, Int Fault Class 1A

SO TRXC, Int Fault Class 1B

1 Reset, Power On
2 Reset, Switch
3 Reset, Watchdog
4 Reset, SW Fault
5 Reset, RAM Fault
6 Reset, Internal Function Change
7 Radio Baseband Loop Test Fault
8 Timing Reception Fault
9 Signal Processing Fault
10 Tora Dannie Communication Fault
11 DSP CPU Communication Fault
12 Terrestrial Traffic Channel Fault
13 RF Loop Test Fault
14 RU Data Base Corrupted
15 XBus Communication Fault
16 Initiation Fault
17 XInterface Fault
18 DSP Fault
19 Reset, DXU Link Lost
20 HW And IDB Inconsistent
21 Internal Configuration Failed
22 Voltage Supply Fault
23 Air Time Counter Lost
24 High Temperature
25 TX/RX Communication Fault
26 Radio Control System Load
27 Traffic Lost Downlink
28 Traffic Lost Uplink
29 Y Link Communication HW Fault
30 DSP RAM Soft Error
.
.
.47

0 CDU/Combiner Not Usable


1 Indoor Temp Out Of Safe Range
2
3 DC Voltage Out Of Range
4 Indoor Temp Above Safe Range
5 Indoor Temp Below Safe Range
6 SCTRL Communication Lost
7 TX Address Conflict
8 Y Link Communication Fault
9 Y Link Communication Lost
10 Timing Reception Fault
.

SO TRXC, Int Fault Class 2A

SO TRXC External Condition Class 1

0 RX Cable Disconnected
1 RX EEPROM Checksum Fault
2 RX Config Table Checksum Fault
3 RX Synthesizer Unlocked
4 RX Internal Voltage Fault
5 Astra Dixie Communication Fault
6 Astra Tracy Communication Fault
7 TX EEPROM Checksum Fault
8 TX Config Table Checksum Fault
9 TX Synthesizer Unlocked
10 TX Internal Voltage Fault
11 TX High Temperature
12 TX Output Power Limits Exceeded
13 TX Saturation
14 Voltage Supply Fault
15 VSWR/Output Power Supervision Lost
16 NonVolatile Memory Corrupted
17 Loadfile Missing in TRU
18 DSP Fault
19 High Frequency Software Fault
20 RX Initiation Fault
21 TX Initiation Fault
22 CDUBus Communication Fault
23 Default Values Used
24
25 TX Max Power Restricted
26 DB parameter fault
27
28 PFWD/PREF Measurement Access Failure
29 Power Amplifier Fault
30 CPU High Temperature
31
32 RX High Temperature
33 Inter TRX Communication Fault
34
35 Traffic Burst Inhibit
36 RX Filter Loadfile Checksum Fault
37 RX Internal Amplifier Fault
38 Climate Capacity Reduced
39 RF-loop Test Fault, Degraded RX
40 Memory Fault
43 INTERNAL HC LOAD POWER FAULT
.
47

0
1
2
3
4 L/R SWI (TRU In Local Mode)
5 L/R TI (Local to Remote while Link Lost)
6
7
8
9
10
11
12
13
14
15

SO TRXC, Rep Unit Map


0 TRU, dTRU or ATRU
1
2 MICRO RBS
3 CXU dTRU RXA CABLE
4 CXU dTRU RXB CABLE
5 CDU CXU RXA CABLE
6 CDU CXU RXB CABLE
7 CDU TO ATRU RX CABLE
8 SCTRL BUS CABLE
9 ATRU TO SCU PFWD/PREF CABLE
10 CDU TO TRU PFWD CABLE
11 CDU TO TRU PREFL CABLE
12 CDU TO TRU RXA CABLE
13 CDU TO TRU RXB CABLE

AO RX, Internal Fault Map Class 2A

AO TX, Int Fault Map Class 1B

0 CXU Supervision/Communication Fault


1 RX Path Lost on A receiver side
2 RX Path Lost on B receiver side

0 CU/CDU Not Usable


1 CDU/Combiner VSWR Limits Exceeded
2 CDU Output Power Limits Exceeded
3
4 TX Antenna VSWR Limits Exceeded
5
6 TX EEPROM Checksum Fault
7 TX Config Table Checksum Fault
8 TX Synthesizer A/B Unlocked
9 TX Synthesizer C Unlocked
10 Astra Tracy Communication Fault
11 TX Internal Voltage Fault
12 TX High Temperature
13 TX Output Power Limits Exceeded
14 TX Saturation
15
16
17 TX Initiation Fault
18 CU/CDU HW Fault
19 CU/CDU SW Load/Start Fault
20 CU/CDU Input Power Fault
21 CU/CDU Park Fault
22 VSWR/Output Power Supervision Lost
23 CU/CDU Reset, Power On
24 CU/CDU Reset, Communication Fault
25 CU/CDU Reset, Watchdog
26 CU/CDU Fine Tuning Fault
27 TX Max Power Restricted
28 CDU High Temperature
29 SCU Voltage Supply Fault
.
.
47 TX Auxiliary Equipment Fault

AO TX, Int Fault Map Class 2A

AO TX, Internal Fault Map Class 1A

0 TX Diversity Fault
.
.
47

0 TX Offending
.
.
47

AO RX, Internal Fault Map Class 2A


0 CXU Supervision/Communication Fault
1 RX Path Lost on A receiver side
2 RX Path Lost on B receiver side

.
47 RX Auxiliary Equipment Fault

AO RX, Internal Fault Map Class 1B


0 RXDA Amplifier Current Fault
1 ALNA/TMA Fault
2
3 RX EEPROM Checksum Fault
4 RX Config Table Checksum Fault
5 RX Synthesizer A/B Unlocked
6 RX Synthesizer C Unlocked
7 Astra Dixie Communication Fault
8 RX Internal Voltage Fault
9 RX Cable Disconnected
10 RX Initiation Fault
11 CDU Output Voltage Fault
12 TMA CM Output Voltage Fault
.
.
47 RX Auxiliary Equipment Fault

AO RX, Internal Fault Map Class 2A

AO TF, Int Fault Map Class 1B

0 CXU Supervision/Communication Fault


1 RX Path Lost on A receiver side
2 RX Path Lost on B receiver side

0 Optional Synchronization Source


1 DXUOpt EEPROM Checksum Fault
.
.
47

AO TF, Ext Condition Map Class 1

AO TF, Ext Condition Map Class 2

0 EXT SYNCH (No Usable External Reference)


1 PCM SYNCH (No Usable PCMReference)
2
3
4
5
6
7
8
9
10
11
12
13
14
15

0 EXT SYNCH (No Usable External Reference)


1 PCM SYNCH (No Usable PCMReference)
2
3
4
5
6
7
8
9
10
11
12
13
14
15

ACCU
ALNA
ASIC
BDM
BFU
CDU
CM
CON
CU
CXU
DB
DP
DSP
dTRU
DXU
DU
ECU
EPC
ESB
FCU
FU
IDB
IOM
IS
IXU
PCM
PCU
PFWD
PREFL
PSU
PWU
RBS
RBS DB
RF
RRU
RU
RX
RXU
TF
TG
TIM
TMA
TRA
TRS
TRU
TRXC

AC Connection Unit
Antenna Low Noise Amplifier
Application Specific Integrated
Battery and Distribution Module
Battery Fuse Unit
Combining and Distribution Unit
Control Module
LAPD Concentrator
Combining Unit
Configuration Switch Unit
Data Base
Digital Path
Digital Signal Processor
double TRU
Distribution Switch Unit
Distribution Unit
Energy Control Unit
Environment and Power Control
External Synchronization Bus
Fan Control Unit
Filter Unit
Installation Data Base
Internal O&M
Interface Switch
Interface and Switching Unit
Pulse Code Modulation
Packet Control Unit
Power Forward
Power Reflected
Power Supply Unit
Power Unit
Radio Base Station
RBS Database
Radio Frequency
Remote Radio Unit
Replaceable Unit
Receiver
Receiver Unit
Timing Function
Transceiver Group
Transmission Interface
Tower Mounted Amplifier
Transcoder Rate Adaptor
Transceiver system
Transceiver Unit
Transceiver Controller

TS
TU
TX
TXU
VCO
VSWR

Time Slot
Timing Unit
Transmitter
Transmitter Unit
Voltage Controlled Oscillator
Voltage Standing Wave Ratio