Professional Documents
Culture Documents
72
www.DaikinApplied.com
1
5
8
9
4
3
6
12
Piping vestibule
Encloses piping connections within unit cabinet
Variable depths to meet your piping requirement
Motor control
Disconnect switches: non-fused, fused, circuit breaker
Starters: IEC and NEMA type
VFDs: McQuay, ABB, Danfoss
10
11
12
www.DaikinApplied.com
73
Use Daikin Skyline as a product platform on which to build the ideal outdoor air handler for your specific
application. Options include:
Multiple section depths
Various casing and drain pan
materials
Mixing boxes/economizers
Sound attenuators
Electro-Fin epoxy coil coating
Multiple coil section depths
Humidifier manifold
IBC seismic certification
Gas-phase filtration
Miami-Dade hurricane certified
Unitized base
PLENUM FAN
HORIZ
HEA IN
M
U
N
LE
D
IF
FU
SE
R
B
LE
N
D
ER
EC
O
N
O
M
IZ
ER
R
EX ET
H UR
A N
U
ST /
System Options
HORIZ
PLENUM FAN
MI IN
O
74
www.DaikinApplied.com
003
900 2500
004
006
008
010
012
014
017
021
1200
3100
1950
36 40
1700
4600
2850
38 52
2200
6000
3750
40 58
2900
7700
4800
44 64
3600
9700
6050
50 66
420011,200
7000
50 74
500013,500
8400
52 80
600016,000
10050
58 82
www.DaikinApplied.com
75
21.9
20.1
17.2
15.8
14.4
52
54
52
68
66
40
40
40
30
34
52
84
42
48
12
30
22
42
16
40
12
30
16
24
24
36
16
24
30
36
42
48
54
16
22
40
52
64
28
025
030
035
045
055
065
080
085
090
730019,400
12,150
66 86
850022,500
14,150
66 98
10,00026,500
16,700
72 102
960025,500
19,300
84 106
11,40030,200
24,500
96 106
20,00054,000
33,300
92 136
21,50057,500
35,900
98 136
23,10061,600
38,450
104 136
24,60065,600
41,000
110 136
50
54
58
Mixing box with angular filter
68
72
76
Economizerdepth, in
Depth
84
86
100
106
112
92
100
108
Blenderdepth, in
Largest Kees
46
48
58
64
68
76
80
84
Largest Blender Products IV
52
60
64
70
70
88
88
92
Side load filter sectionsdepth, in
Flat 2" and 4"
12
12
12
12
12
12
12
12
2" angular
32
32
32
32
32
32
32
32
Cartridge (12" deep w/ 2" pre-filter)
22
22
22
22
22
22
22
22
Bag (36" w/ 2"pre-filter)
42
42
42
44
44
42
42
42
Front load filter sectionsdepth, in
Cartridge (12"deep w/ 2"pre-filter)
16
16
16
20
20
16
16
16
Bag (36" w/ 2"pre-filter)
40
40
40
44
44
40
40
40
Face and bypassdepth, in
Internal
12
12
12
12
12
12
12
12
External
32
32
34
44
50
50
54
56
Coil sectionsdepth, in
Heating only (2-row water)
12
12
12
16
16
12
12
12
Cooling only (4-row water)
36
36
36
48
48
18
18
18
Cooling only (6-row water)
42
42
42
48
48
24
24
24
Clg (12-row) & reheat (1-row)
42
42
42
42
42
36
36
36
Access sectionsdepth, in
16" deep
16
16
16
16
16
16
16
16
24" deep
24
24
24
24
24
24
24
24
30" deep
30
30
30
30
30
30
30
30
36" deep
36
36
36
36
36
36
36
36
42" deep
42
42
42
42
42
42
42
42
48" deep
48
48
48
48
48
48
48
48
54" deep
54
54
54
54
54
54
54
54
Diffuserdepth, in
With housed fan
24
24
24
30
30
30
30
30
With inline fan
26
26
28
30
32
38
38
38
Attenuatordepth, in
Short
40
40
40
40
40
40
40
40
Medium
52
52
52
52
52
52
52
52
Long
64
64
64
64
64
64
64
64
Supply or return plenumdepth, in
Top, bottom or end opening
30
30
32
32
40
42
48
52
* Based on typical industry sizes. Skyline air handling units are available in 2 inch increments of height and width to fit the exact space requirements.
Front load filter sections include 24" upstream plenum section with tread plate for heavy duty floor liner.
76
92.2
82.0
71.8
61.5
56.4
92
96
82
N/A
N/A
52
64
52
56
60
78
112
84
92
12
32
22
42
16
40
12
58
12
18
24
36
16
24
30
36
42
48
54
30
38
40
52
64
54
www.DaikinApplied.com
Optional electrical
Optional heating
Available L O N M A R K certified
www.DaikinApplied.com
77
RoofPak Model RDS and RAH Air Handlers4,000 to 50,000 cfm Features and Options
Airfoil fans
More energy
efficient and
quieter than
forward curved
fans
Double width,
double inlet (DWDI) or single
width, single inlet (SWSI) plenum
fans
Economizer
Outside air enters from both
sides, improving mixing for better
temperature control
DesignFlow Precision Ventilation
Air Control System accurately
measures and maintains
ventilation air intake
Patented UltraSeal low leak
dampers minimize air leakage,
reducing energy costs
78
Factory-mounted variable
frequency drives
Control fan motor
speed for lower fan
operating costs and
sound levels in VAV
systems
Blank sections
Available throughout unit to
factory-mount air blenders,
carbon or charcoal filters, sound
attenuators (shown), humidifiers,
or other specialty equipment
Allow customizing for maximum
system performance and
efficiency
Reduced design
and installation
costs
www.DaikinApplied.com
6
8
Air Handling Systems
7
1
10
www.DaikinApplied.com
Durable construction
10
Blow-through or draw-through
cooling coils
Customize the unit to fit the
application and building load
Blow through provides greater
sensible heat ratios and colder
unit leaving air temperature per
ton
Draw-through arrangement
provides more dehumidification
per ton
Factory-installed valve packages
are offered for many chilled
water, hot water, and steam coils
79
RoofPak Model RDS and RAH Air Handlers Features and Options
Supply Air
Outside Air
Return Air
Energy recovery wheel
Recovers approximately 75% of the energy from exhaust air
stream
Allows mechanical refrigeration, heating, and humidifying
capacities to be reduced, offsetting the initial cost of the energy
recovery wheel
Cuts winter humidification energy costs by up to 60%
Provides 100% more summer energy recovery than sensible-only
energy recovery devices
Helps provide a comfortable and affordable indoor environment
Satisfies ASHRAE Standard 90.1 requirements for energy recovery
on applications involving more than 70% minimum outdoor air
and 5000 total cfm
80
www.DaikinApplied.com
Unit size
708B
800C
802C
/HQJWKLQ
+HLJKWLQ
51.0
55.5
55.5
:LGWKLQ
67.5
94.0
94.0
Cabinet Dimensions
7\SH)RUZDUGFXUYHG
4W\GLDPHWHULQ
124
4W\GLDPHWHULQ
4W\GLDPHWHULQ
$LURZUDQJHFIP
0RWRUKSUDQJH
7\SH%DFNZDUGFXUYHG
4W\GLDPHWHULQ
124
$LURZUDQJHFIP
0RWRUKSUDQJH
7\SH$LUIRLO
4W\GLDPHWHULQ
116
120
$LURZUDQJHFIP
0RWRUKSUDQJH
Return Fans
7\SH)RUZDUGFXUYHG
4W\GLDPHWHULQ
1
$LURZUDQJHFIP
0RWRUKSUDQJH
4W\GLDPHWHULQ
116
130
130
4W\GLDPHWHULQ
140
$LURZUDQJHFIP
0RWRUKSUDQJH
7\SH$LUIRLO
7KURZDZD\3OHDWHG&OHDQDEOHOWHUV
$UHDVTIW
13.91
50.0
50.0
4W\VL]HLQ
$UHDVTIW
20.82
4W\VL]HLQ
6.01
24.0
24.0
4W\VL]HLQ
$UHDVTIW
12.02
4W\VL]HLQ
8.01
24.0
24.0
4W\VL]HLQ
$UHDVTIW
14.02
4W\VL]HLQ
250, 312, 400, 500, 625, 800, 812, 988, 1000, 1250
1RPLQDORXWSXW0%K
200, 250, 320, 400, 500, 640, 650, 790, 800, 1000
1RPLQDO2XWSXWN:
20, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240
Electric3
)LOWHUDUHDIRU5'6%XQLWVZLWKDVXSSO\IDQ
)LOWHUDUHDIRU5'6%XQLWVZLWKDRUVXSSO\IDQ
*DVRLODQGHOHFWULFKHDWVHOHFWLRQLVOLPLWHGE\WKHPLQLPXPDLURZUHTXLUHPHQWV
www.DaikinApplied.com
81
Supply Fans
708BS
708BL
800CY
802CY
Without
With
Without
With
Without
With
Without
With
)LQKHLJKWLQ2
12-39
12-30
12-39
12-30
12-36
12-30
12-36
12-30
)LQOHQJWKLQ
36
36
48
48
79
79
79
79
0D[FRLOGHSWKLQ3
25.0
20.0
25.0
20.0
19.5
19.5
19.5
19.5
0D[IDFHDUHDVTIW
9.8
7.5
13.0
10.0
19.8
16.5
19.8
16.5
%\SDVV$UHDVTIW
1.9
2.5
3.3
3.3
0D[E\SDVVFIP
4,750
6,250
8,225
8,225
Physical
5MH2
5MH2
:+
:+
:/
:/
7\SHURZV
5MS2
5MS2
:6
:6
:0
:0
:'
:'
Evaporator coils
'LDPHWHULQ
7\SHURZV
6(1
6(1
SER6
SER6
SEF2, 3, 4, 5, 6, 8
SEF2, 3, 4, 5, 6, 8
SEJ3, 4,6, 8
SEJ3, 4,6, 8
6(.
6(.
7\SHURZV
6:%
:%
:4
:4
:+
:+
6:6
5MH24
5MS24
6WHDPFRLOV
'LDPHWHULQ
7\SHURZV
-$
-$
*$
*$
-$
-$
*$
*$
&RQWUDFWRUFRLOVKDYHRSSRVLWHGULYHHQGFRQQHFWLRQV
2QWKH5'6%&DQG&FRQWUDFWRUFRLOVDYDLODEOHZLWKQKHLJKWVEHWZHHQJLYHQUDQJHRILQFUHPHQWV
2QWKH5'6%WKHPD[LPXPFRLOGHSWKGRHVQRWLQFOXGHWKHVSDFHUSURYLGHGEHWZHHQWKHODVWWZRFRLOV
,IFRROLQJFRLOLVLQWKHVDPHVHFWLRQWKHFRROLQJFRLOLVOLPLWHGWRURZV
5/8
39
75
Type/rows, steam
5JA/1
82
www.DaikinApplied.com
Unit size
800CL
802CL
:+&
:+&
:/&
:/&
:6&
:6&
)LQVSHULQFK
8, 10, 12
8, 10, 12
)+)/LQ
)DFHDUHDIW2
26.0
26.0
0D[LPXP$LURZFIP
16,900
16,900
FRSSHUVZHDW
FRSSHUVZHDW
7\SHURZVQJHRPHWU\
(1&
(-&
)LQVSHULQFK
8, 10, 12
8, 10, 12
)+)/LQ
)DFHDUHDIW2
27.3
27.3
0D[LPXPDLURZFIP
17,750
17,750
Evaporator coils
&RPSUHVVRUFLUFXLWVVSOLW
/LTXLGFRQQHFWLRQLQ
2'0FRSSHU
2'0FRSSHU
6XFWLRQFRQQHFWLRQLQ
2'6FRSSHU
2'6FRSSHU
:++
:++
:6&
:6&
20.3
20.3
21.1
21.1
9DOYHSDFNDJHLQ
2'0FRSSHU
2'0FRSSHU
7\SHURZVQJHRPHWU\
-$+
-$+
)LQVSHULQFK
6, 12
6, 12
Steam coils
20.3
20.3
21.1
21.1
9DOYHSDFNDJHLQ
037LURQ
037LURQ
8QLWFRLOVDUH+,)QGHVLJQDQGKDYHRSSRVLWHGULYHHQGFRQQHFWLRQVH[FHSWWRWKHKHDWRQO\VHFWLRQ
9DOYHSDFNDJHDYDLODEOHLQFRROLQJRQO\DQGKHDWLQJRQO\VHFWLRQV
)RUFRLOVZLWKIDFWRU\YDOYHSDFNDJHVXSSO\DQGUHWXUQFRQQHFWLRQVDUHWKHVL]HRIWKHYDOYHZLWKIHPDOHWKUHDGLQJ
www.DaikinApplied.com
83
9DOYH3DFNDJHLQ
6XSSO\ UHWXUQFRQQLQ
Data
/HQJWKLQ
&DELQHW
047CS
047CL
047CY
077CS
077CL
077CY
96-600
+HLJKWLQ
73.0
:LGWKLQ
99.0
97.0
99.0
Throwaway
7KURZDZD\OWHUV
VWDQGDUG
$UHDIW2
73.9
116.1
4W\VL]HLQ
$UHDIW2
73.9
116.1
4W\VL]HLQ
$UHDIW2
40.0
56.0
4W\VL]HLQ
$UHDIW2
48.0
64.0
4W\VL]HLQ
$UHDIW2
80.0
4W\VL]HLQ
$UHDIW2
40.0
56.0
4W\VL]HLQ
$UHDIW2
48.0
64.0
4W\VL]HLQ
$UHDIW2
80.0
4W\VL]HLQ
'LDPHWHULQFK
27, 30, 33
33, 36, 40
0D[DLURZFIP
30,000
50,000
0RWRUKSUDQJH
30% pleated
3UHOWHUVWDQGDUGRZ
7KURZDZD\OWHUV
RSWLRQDO
3UHOWHUPHGLXPRZ
3UHOWHUKLJKRZ
RUVWDQGDUGRZ
RUPHGLXPRZ
&DUWULGJHOWHUV
RSWLRQDO
RUKLJKRZ
Airfoil
6:6,VXSSO\IDQV
'LDPHWHULQFK
40, 44
44, 49
0D[DLURZFIP
30,000
50,000
0RWRUKSUDQJH
Airfoil
5HWXUQIDQV
'LDPHWHULQFK
40
44
0D[DLURZFIP
27,000
45,000
0RWRUKSUDQJH
Propeller
'LDPHWHULQFK
([KDXVWIDQV
,QFK
4XDQWLW\
3HU8QLW
3HU8QLW
0RWRUKS
(OHFWULF
*DVIXUQDFH
+3(DFK
$LURZUDQJHFIP
1RPRXWSXWN:
,QSXW0%K
250 312 400 500 625 800 812 988 100 1250*
1RPRXWSXW0%K
200 250 320 400 500 640 650 790 800 1000
500 640 650 650 790 800 1000 1100 1400 1500 2000*
)XUQDFHVL]HDYDLODELOLW\LVOLPLWHGE\WKHPLQLPXPDLURZSHU7DEOHRQSDJH
84
www.DaikinApplied.com
047CS
wo/ F&BP
047CL
w/ F&BP2
wo/ F&BP
077CS
w/ F&BP2
5RZV
wo/ F&BP
w/ F&BP2
3, 4, 5, 6
)LQVSHULQFK
8, 10, 12,
)LQPDWHULDO
$OXPLQXPFRSSHU
)+):LQ
077CL
w/ F&BP2
)DFHDUHD
VTIW
40.1
47.4
54.7
76.6
0D[FIP
26,000
30,800
35, 500
49,800
:+
:/
7\SHURZV
9DOYHSDFNDJH
LQ
:6
:0
&KLOOHGZDWHU
FRLOV
:'
)LQVSHULQFK
8, 10, 12
)LQPDWHULDO
$OXPLQXPFRSSHU
)+):LQ
)DFHDUHD
VTIW
38.0
27.7
45.0
45.01
51.9
36.3
72.6
62.3
0D[IDFHFIP
24,700
18,000
29,200
29,200
33,700
23,600
47,200
40,500
%\SDVV$UHD
VTIW
9.2
10.4
14.4
18.4
0D[E\SDVV
FIP
23,000
25,900
36,000
46,100
:+
7\SHURZV
9DOYHSDFNDJH
LQ
+RWZDWHUFRLOV
:6
)LQVSHULQFK
)LQPDWHULDO
$OXPLQXPFRSSHU
)+):LQ
)DFHDUHD
VTIW
29.7
20.3
29.7
42.2
28.1
42.2
%\SDVVDUHD
VTIW
9.2
14.4
0D[E\SDVV
FIP
23,000
36,000
5RZV
9DOYHSDFNDJH
LQ
1, 2
)LQVSHULQFK
6, 12
)LQPDWHULDO
6WHDPFRLOV
$OXPLQXPFRSSHU
)+):LQ
)DFHDUHD
VTIW
29.7
20.3
29.7
42.2
28.1
42.2
%\SDVVDUHD
VTIW
9.2
14.4
0D[E\SDVV
FIP
23,000
36,000
8QLWFRLOVDUH+,)QGHVLJQ
)DFHDQGE\SDVVGDPSHUVDUHDYDLODEOHRQO\LQKHDWLQJRQO\RUFRROLQJRQO\VHFWLRQV
7KHYDOYHSDFNDJHIRUKRWZDWHUDQGVWHDPKHDWLVDYDLODEOHRQO\LQWKHKHDWLQJRQO\VHFWLRQ
www.DaikinApplied.com
85
(YDSRUDWRU
FRLOV
wo/ F&BP