Marshalling Cabinet or Marshalling Panel


As discussed in the Typical Architecture of Instrumentation and Automation System, the automation
architecture of the plant is having a marshalling cabinet in between the junction box and the system cabinet.
This marshalling cabinet function is to interface the incoming field cable (which is normally a multipair cable)
and the I/O (Input/Output) card connection. Without marshalling cabinet, we can sure (for large number of
I/O) that there will be a trouble for operation personnel to maintain and operate the cabling.

Search This Blog


Search

Follow by Email
Email address...

One of the important interface function of the marshalling cabinet is the cross wiring function. Cross wiring is
always necessary since the incoming field signal and the channel quantity of the I/O card is always different.
For example lets say we have a 24 pair incoming field cable that carry 20 field analogue signal. This field signal
will be split at least into two analogues 16 channel I/O card. The First 16 I/O will be in the first 16 channel I/O
card and the other 4 will be in the next 16 channel I/O card. To have this split wiring (cross wiring) in the
system cabinet is not a good practice from the operation and maintenance point of view. Thus the marshalling
cabinet is needed.

Another cause of the cross wiring is the mixed of I/O signals that coming from the field. The incoming multipair
cable can have mixed AI (Analaogue Input) and AO (Analogue Output) signal in the same multipair cable. This
mixed signal will be split in the marshalling cabinet so that the AI signal will be terminated in the dedicated AI
termination board and so do the AO signal.

In some application such as voting application for safety system (i.e. 2oo3 voting) there is a requirement to
have the I/O signal allocated in the different I/O card so that the common fault cause can be avoided. This
application ofcourse once again need a cross wiring in the marshalling cabinet.

In typical application, the marshalling cabinet is having the following cable routing.

1.

The multipair field cables enter the marshalling cabinet through the bottom part of the cabinet.

2.

Then each wire of the incoming multipair field cable is terminated in the surge protection devices or
surge arrester. If there is no requirement of such surge protection devices, each wire is terminated in
the terminal block.

3.

From the surge protection devices, in Non IS application, there will be a cross wiring that match the
field signal and the I/O address assignment in the termination board. If the system is IS, then before
cross wiring, each wire connection is routed first to the IS Barrier.

4.

The dedicated system cable that has a plug and play connection is then routed from the termination
board to the I/O card in the system cabinet.

5.

Some termination board may require a dedicated DC power supply that can be taken from the DC
power supply in the marshalling cabinet.

As an illustration, see below drawing that shows the simplified marshalling cabinet arrangement in the oil and
gas industries. In actual marshalling cabinet arrangement, the equipment arrangement may vary from each
automation vendor, but in typical they will have more or less the same equipment as below drawing.

Submit

Popular Posts
Earthing System of Instrument
Equipment
Instrument earthing system shall
consist of the following earth type:
Electrical earthing (also called
dirty earthing or Pr...
Marshalling Cabinet or Marshalling
Panel
As discussed in the Typical
Architecture of Instrumentation and
Automation System , the automation
architecture of the plant is having a ...
Valve Manifold for Pressure
Transmitter
Valve manifold is a standard
accessory for pressure transmitter and
differential pressure transmitter. By
providing a valve manifold in t...
Flow Direction of Control Valves
Flow direction of control valves has a
relationship with a failure action, High
Delta Pressure, Cavitation, and %
opening of the valve. ...
The Difference Between API and
ASME Pressure Safety Valve (PSV)
In the vendor data sheet, calculation
sheet, and or catalogue of the PSV, it
was stated two different terms which is
API and ASME PSV th...
2 Wires, 3 Wires, or 4 Wires RTD
(Resistance Temperature Detector)?
RTD is a temperature sensitive metal.
The resistance of the RTD metal is
gradually changed with the changed of
temperature. In applicati...
Typical Architecture of Instrumentation
& Automation System
In general application, the
instrumentation and automation
architecture is consist of field
instruments, individual & multicore
cabl...

Labels
Commissioning
Instrument
Maintenance

http://ongengineering.blogspot.fr/2013/03/marshalling-cabinet-or-marshalling-panel.html

1/3

11/17/2014

Oil and Gas Engineering: Marshalling Cabinet or Marshalling Panel


Material
Piping
safety

+1 Recommend this on Google

Labels: Instrument

No comments:
Post a Comment

http://ongengineering.blogspot.fr/2013/03/marshalling-cabinet-or-marshalling-panel.html

2/3

11/17/2014

Oil and Gas Engineering: Marshalling Cabinet or Marshalling Panel

Enter your comment...

Comment as:

Publish

Newer Post

Google Account

Preview

Home

Older Post

Subscribe to: Post Comments (Atom)

Awesome Inc. template. Powered by Blogger.

http://ongengineering.blogspot.fr/2013/03/marshalling-cabinet-or-marshalling-panel.html

3/3

You might also like