You are on page 1of 8

Table 1 Coefficients for Negative Moments for Slab (Continuous Edge)

CASE

Ratio
2

0.050

0.075

0.071

0.033

0.061

0.061

0.033

0.038

0.065

0.056

0.029

0.043

0.068

0.052

0.025

0.049

0.072

0.046

0.021

0.055

0.075

0.041

0.017

0.061

0.078

0.036

0.014

0.068

0.081

0.029

0.011

0.074

0.083

0.024

0.008

0.080

0.085

0.018

0.006

0.085

0.086

0.014

0.005

0.089

0.088

0.010

0.003

1.00 CA neg

0.045

CB neg

0.045

0.95 CA neg

0.050

CB neg

0.041

0.90 CA neg

0.055

CB neg

0.037

0.85 CA neg

0.060

CB neg

0.031

0.80 CA neg

0.065

CB neg

0.027

0.75 CA neg

0.069

CB neg

0.022

0.70 CA neg

0.074

CB neg

0.017

0.65 CA neg

0.077

CB neg

0.014

0.60 CA neg

0.081

CB neg

0.010

0.55 CA neg

0.084

CB neg

0.007

0.50 CA neg

0.086

CB neg

0.006

1
2
3
4
5
6
7
8
9

A
m
B

0.076

0.050
0.055

0.072

CASE1: All sides discontinuous


CASE2: All sides Continuous
CASE3: Both short sides continuous
CASE4: One short and one long sides continuous
CASE5: Both long sides continuous
CASE6: One long side continuous
CASE7: One short side continuous
CASE8: One long and two short sides continuous
CASE9: One short and two long sides continuous

0.057
0.083

0.086
0.051

0.085

0.088
0.044

0.086

0.091
0.038

0.087

0.093
0.031

0.088

0.095
0.024

0.089

0.096

0.008
0.094

0.022

0.083

0.011
0.092

0.028

0.082

0.015
0.089

0.035

0.062

0.019
0.085

0.043

0.079

0.024
0.081

0.050

0.080

0.029
0.076

0.056

0.067

0.034
0.071

0.061

0.075

0.040
0.066

0.065

0.079

0.045
0.060

0.070

0.071

0.006

0.019
0.090

0.097
0.014

Table 2 Coefficients for Dead Load Positive Moments in Slabs


CASE

Ratio
2

A
m
B

1 CA DL

0.036

0.018

0.018

0.027

0.027

0.033

0.027

0.020

0.023

CB DL

0.036

0.018

0.027

0.027

0.018

0.027

0.033

0.023

0.020

0.95 CA DL

0.040

0.020

0.021

0.030

0.028

0.036

0.031

0.022

0.024

CB DL

0.033

0.016

0.025

0.024

0.015

0.024

0.031

0.021

0.017

0.9 CA DL

0.045

0.022

0.025

0.033

0.029

0.039

0.035

0.025

0.026

CB DL

0.029

0.014

0.024

0.022

0.013

0.021

0.028

0.019

0.015

0.85 CA DL

0.050

0.024

0.029

0.036

0.031

0.042

0.040

0.029

0.028

CB DL

0.026

0.012

0.022

0.019

0.011

0.017

0.025

0.017

0.013

0.8 CA DL

0.056

0.026

0.034

0.039

0.032

0.045

0.045

0.032

0.029

CB DL

0.023

0.011

0.020

0.016

0.009

0.015

0.022

0.015

0.010

0.75 CA DL

0.061

0.028

0.040

0.043

0.033

0.048

0.051

0.036

0.031

CB DL

0.019

0.009

0.018

0.013

0.007

0.012

0.020

0.013

0.007

0.7 CA DL

0.068

0.030

0.046

0.046

0.035

0.051

0.058

0.040

0.033

CB DL

0.016

0.007

0.016

0.011

0.005

0.009

0.017

0.011

0.006

0.65 CA DL

0.074

0.032

0.054

0.050

0.036

0.054

0.065

0.044

0.034

CB DL

0.013

0.006

0.014

0.009

0.004

0.007

0.014

0.009

0.005

0.6 CA DL

0.081

0.034

0.062

0.053

0.037

0.056

0.073

0.048

0.036

CB DL

0.010

0.004

0.011

0.007

0.003

0.006

0.012

0.007

0.004

0.55 CA DL

0.088

0.035

0.071

0.056

0.038

0.058

0.081

0.052

0.037

CB DL

0.008

0.003

0.009

0.005

0.002

0.004

0.009

0.005

0.003

0.5 CA DL

0.095

0.037

0.080

0.059

0.039

0.061

0.089

0.056

0.038

CB DL

0.006

0.002

0.007

0.004

0.001

0.003

0.007

0.004

0.002

1
2
3
4
5
6
7
8
9

CASE1: All sides discontinuous


CASE2: All sides Continuous
CASE3: Both short sides continuous
CASE4: One short and one long sides continuous
CASE5: Both long sides continuous
CASE6: One long side continuous
CASE7: One short side continuous
CASE8: One long and two short sides continuous
CASE9: One short and two long sides continuous

Table 3 Coefficients for Live Load Positive Moments in Slabs


CASE

Ratio
1

A
m
B

1 CA LL

0.036

0.027

0.027

0.032

0.032

0.035

0.032

0.028

0.030

CB LL

0.036

0.027

0.032

0.032

0.027

0.032

0.035

0.030

0.028

LL

0.040

0.030

0.031

0.035

0.034

0.038

0.036

0.031

0.032

0.95 CA

CB LL

0.033

0.025

0.029

0.029

0.024

0.029

0.032

0.027

0.025

0.9 CA LL

0.045

0.034

0.035

0.039

0.037

0.042

0.040

0.035

0.036

CB LL

0.029

0.022

0.027

0.026

0.021

0.025

0.029

0.024

0.022

0.85 CA LL

0.050

0.037

0.040

0.043

0.041

0.046

0.045

0.040

0.039

CB LL

0.026

0.019

0.024

0.023

0.019

0.022

0.026

0.022

0.020

0.8 CA LL

0.056

0.041

0.045

0.048

0.044

0.051

0.051

0.044

0.042

CB LL

0.023

0.017

0.022

0.020

0.016

0.019

0.023

0.019

0.017

0.75 CA LL

0.061

0.045

0.051

0.052

0.047

0.055

0.056

0.049

0.046

CB LL

0.019

0.014

0.019

0.016

0.013

0.016

0.020

0.016

0.013

0.7 CA LL

0.068

0.049

0.057

0.057

0.051

0.060

0.063

0.054

0.050

CB LL

0.016

0.012

0.016

0.014

0.011

0.013

0.017

0.014

0.011

0.65 CA LL

0.074

0.053

0.064

0.062

0.055

0.064

0.070

0.059

0.054

CB LL

0.013

0.010

0.014

0.011

0.009

0.010

0.014

0.011

0.009

0.6 CA LL

0.081

0.058

0.071

0.067

0.059

0.068

0.077

0.065

0.059

CB LL

0.010

0.007

0.011

0.009

0.007

0.008

0.011

0.009

0.007

0.55 CA LL

0.088

0.062

0.080

0.072

0.063

0.073

0.085

0.070

0.063

CB LL

0.008

0.006

0.009

0.007

0.005

0.006

0.009

0.007

0.006

0.5 CA LL

0.095

0.066

0.088

0.077

0.067

0.078

0.092

0.076

0.067

CB LL

0.006

0.004

0.007

0.055

0.004

0.005

0.007

0.005

0.004

1
2
3
4
5
6
7
8
9

CASE1: All sides discontinuous


CASE2: All sides Continuous
CASE3: Both short sides continuous
CASE4: One short and one long sides continuous
CASE5: Both long sides continuous
CASE6: One long side continuous
CASE7: One short side continuous
CASE8: One long and two short sides continuous
CASE9: One short and two long sides continuous

Standard Reinforcing Mild Steel Bar Diameter and Cross Sectional Area
Bar No Bar Dia (mm) Bar Dia (in) Area (mm2)
8 mm
8
0.315
50.27
10 mm
10
0.394
78.54
12 mm
12
0.472
113.10
14 mm
14
0.551
153.94
16 mm
16
0.630
201.06
20 mm
20
0.787
314.16
22 mm
22
0.866
380.13
25 mm
25
0.984
490.87
28 mm
28
1.102
615.75
32 mm
32
1.260
804.25
38 mm
38
1.496
1134.11
#3
9.5
0.375
71.26
#4
12.7
0.500
126.68
#5
15.9
0.625
197.93
#6
19.1
0.750
285.02
#7
22.2
0.875
387.95
#8
25.4
1.000
506.71
#9
28.7
1.128
644.73
#10
32.3
1.270
817.27
#11
35.8
1.410
1007.39
#14
43.0
1.693
1452.35

Area(in )
0.08
0.12
0.18
0.24
0.31
0.49
0.59
0.76
0.95
1.25
1.76
0.11
0.20
0.31
0.44
0.60
0.79
1.00
1.27
1.56
2.25

Load Calculation on Slabs

Yield stress of mild steel, fy (psi)

60000

28-days comp strength of concrete, f'c (psi)


Thickness of the slab, t (in)
Effective Depth in A direction, dA (in)

3000
4.5
3.5

Effective Depth in B direction, dB (in)


Assuming 1ft strip of slab, b (in)

3
12

Service Dead Load, wDL (psf)

195

Service Live Load, wLL (psf)

40

Factored Dead Load, wu,DL=1.2DL(psf)

234

Factored Live Load, wu,LL =1.6LL (psf)

64

Factored Load, wu =wu,DL+wu,LL (psf)

298

Slab No
Slab Case No
Short Clear Span, A (ft)
Long Clear Span, B (ft)
Ratio m

A
B

S1
S2
S3
7
9
9
11.0833
14.5
9.5
15
15.5833 15.5833
0.73889 0.93048 0.60963

***MATCH function doesnot work with MROUND properly, so


input the ratio, m manually otherwise it will not work
Rounding ratio,m
CA,neg

0.75

0.95

0.60

0.75
0.000

0.95
0.065

0.60
0.085

CB,neg

0.044

0.029

0.006

CA,DL

0.051

0.024

0.036

CB,DL

0.020

0.017

0.004

CA,LL

0.056

0.032

0.059

0.020

0.025

0.007

CB,LL
2

MA,neg=CA,negwu*A (lb-ft/ft)
2

MB,neg=CB,negwu*B (lb-ft/ft)
2

MA,DL=CA,DLwu,DL*A (lb-ft/ft)
2

MB,DL=CB,DLwu,DL*B (lb-ft/ft)
2

MA,LL=CA,LLwu,LL*A (lb-ft/ft)
MB,LL=CB,LLwu,LL*B2 (lb-ft/ft)
MA,pos=MA,DL+MA,LL (lb-ft/ft)
MB,pos=MB,DL+MB,LL (lb-ft/ft)
1

MA,neg,discont= /3*MA,pos (lb-ft/ft) ***if any


MB,neg,discont=1/3*MB,pos (lb-ft/ft) ***if any

4072.54 2286.03

2950.2 2098.63 434.198


1465.98 1180.76 760.266
1053

966.019 227.299

440.26 430.592 340.784


288

388.544 108.792

1906.24 1611.36 1101.05


1341

1354.56 336.091

635.412 537.119 367.017


447

451.521 112.03

As,min=0.0018bt for fy=60000 psi (in2/ft)


As required for MA,neg (in2/ft)

0.0972
0

0.0972

0.0972

0.28063 0.15158

As required for MA,pos (in2/ft)

0.12544 0.10542 0.07133

As required for MA,neg,discont (in2/ft) ***if any

0.04081 0.03443 0.02346

As required for MB,neg (in /ft)

0.23687 0.16427 0.03251

As required for MB,pos (in /ft)

0.10279 0.10386 0.0251


2

As required for MB,neg,discont (in /ft) *** if any


2

As for MA,neg (in /ft)

0.03348 0.03382 0.00832


0.0972 0.28063 0.15158

As for MA,pos (in /ft)

0.12544 0.10542 0.0972


2

As for MA,neg,discont (in /ft) ***if any

0.0972

As for MB,neg (in2/ft)

0.23687 0.16427 0.0972

As for MB,pos (in2/ft)

0.10279 0.10386 0.0972

As for MB,neg,discont (in2/ft) *** if any


Bar no used
Area of the reinforcing bar (in2)
Spacing required to fulfill As for MA,neg (in c/c)

0.0972 0.0972 0.0972


#3
#3
#3
0.11
0.11
0.11
13.5802 4.70363 8.70822

Spacing required to fulfill As for MA,pos (in c/c)

10.5231 12.5212 13.5802

Spacing required to fulfill As for MA,neg,discont (in c/c) ***if any

13.5802 13.5802 13.5802

Spacing required to fulfill As for MB,neg (in c/c)

5.5727 8.03543 13.5802

Spacing required to fulfill As for MB,pos (in c/c)

12.8422 12.709 13.5802

Spacing required to fulfill As for MB,neg,discont (in c/c) *** if any


Maximum Spacing Criteria <=2t
Spacing Provided to fulfill As for MA,neg (in c/c)

13.5802 13.5802 13.5802


9
9
9
9
4.5
8.5

0.0972

0.0972

Spacing Provided to fulfill As for MA,pos (in c/c)

Spacing Provided to fulfill As for MA,neg,discont (in c/c) ***if any

Spacing Provided to fulfill As for MB,neg (in c/c)

5.5

Spacing Provided to fulfill As for MB,pos (in c/c)

Spacing Provided to fulfill As for MB,neg,discont (in c/c) *** if any

Depth Check