DIGITAL ELECTRONIC
THERMOCONTROLLER
INDEX
1
1.1
1.2
2
2.1
2.2
2.3
2.4
2.5
3
3.1
3.2
3.3
3.4
4
4.1
4.2
4.3
4.4
4.5
5
6
6.1
6.2
6.3
7
7.1
7.2
7.3
7.4
7.5
INSTRUMENT DESCRIPTION
GENERAL DESCRIPTION
FRONT PANEL DESCRIPTION
PROGRAMMING
PROGRAMMING OF SET POINT
PARAMETERS PROGRAMMING
PARAMETER PROTECTION USING THE PASSWORD
PARAMETERS PROGRAMMING LEVEL
ON / STAND-BY FUNCTION
INFORMATION ON INSTALLATION AND USE
PERMITTED USE
MECHANICAL MOUNTING
ELECTRICAL CONNECTIONS
ELECTRICAL WIRING DIAGRAM
FUNCTIONS
MEASURING AND VISUALIZATION
TEMPERATURE CONTROL
COMPRESSOR PROTECTION FUNCTION AND DELAY
AT POWER-ON
FUNCTION OF KEY U
PARAMETERS CONFIGURATION BY A01
PROGRAMMABLE PARAMETERS TABLE
PROBLEMS , MAINTENANCE AND GUARANTEE
SIGNALLING
CLEANING
GUARANTEE AND REPAIRS
TECHNICAL DATA
ELECTRICAL DATA
MECHANICAL DATA
MECHANICAL DIMENSIONS, PANEL CUT-OUT AND
MOUNTING
FUNCTIONAL DATA
INSTRUMENT ORDERING CODE
1 - INSTRUMENT DESCRIPTION
OPERATING INSTRUCTIONS
Vr. 02 (ENG) - 01/12 - cod.: ISTR-MTLZ10ENG02
4
3
2
1
Out
1 - Key P : Used for setting the Set point and for programming the
function parameters
2 - Key DOWN : Used for decreasing the values to be set and for
selecting the parameters.
3 - Key UP : Used for increasing the value to be set and for
selecting the parameters.
4 - Key U : It can be programmed via the parameter USrb to
turning on and off (stand-by) the device. In the hidden parameter
programming mode its used to modify the visibility of the
parameters (see par. 2.4).
5 - Led SET : Indicates the input in programming mode and the
programming level of the parameters. It also serves to indicate the
Stand-by status.
6 - Led OUT : Indicates the control output status (or the To change the visibility of the parameter, press the key U: the led
SET will change status, indicating the accessibility level of the
temperature control device) on (on), off (off) or inhibited (flashing).
parameter (on = parameter visible; off = parameter hidden).
The access procedure for hidden parameters allows the PASS
2 - PROGRAMMING
parameter to be checked and changed, and is useful therefore if
the password set has been forgotten.
2.1 - PROGRAMMING OF THE SET POINT
Press the key P then release it and the display will show SP
alternating with the set value.
To change it press the UP key to increase the value or DOWN to
decrease it.
These keys increase or decrease the value one digit at a time, but
if the button is pressed for more than one second the value
increase or decreases rapidly, and after two seconds pressed, the
speed increases even more to all the desired valued to be reached
rapidly.
Exiting the Set mode is achieved by pressing the P key or
automatically if no key is pressed for 15 seconds. After that time
the display returns to the normal function mode.
NO
SPDT 16A-AC1
TLZ 10
NO
NC
INPUT
1 2 3 4 5 6 7 8 9 10 11 12
OUT
SUPPLY
PTC-NTC
PROBE
4 - FUNCTIONS
HSEt
ON
tim e
o ff
P tC
HSEt
SP
SP
ON
OUT
SP
time
time
ON
ON
o ff
P tC
HSEt
ON
HSEt
HSEt
ON
t im e
SP
Temp.
ON
ON
ON
o ff
P tC
ON
tim e
o ff
P tC
o ff
P tC
ON
OUT
off
off
OUT
off
off
14
od
Delay at power on
OFF 99.59
min.sec
OFF / 1
OFF
OFF
OFF
4.5 - PARAMETERS CONFIGURATION BY A01
It is possible the transfer from and toward the instrument of the
0.0
functioning parameters through the device A01 with 5 poles
connector.
This device A01 its mainly useable for the serial programming of
6 - PROBLEMS, MAINTENANCE AND GUARANTEE
the instruments which need to have the same parameters
configuration or to keep a copy of the programming of an 6.1 - SIGNALLING
instrument and allow its rapid retransmission.
Error Signalling:
The same device can connect the instrument via USB to a PC and
Error
Reason
Action
through the proper configuration software tools "TECNOLOGIC
The probe may be Check
the
correct
E1
UniversalConf, its possible to configure the operating parameters.
interrupted or in short connection of the probe
-E1
To use the device A01 its necessary that the device or instrument
circuit, or may measure with the instrument and
are being supplied.
a value outside the check the probe works
SUPPLY
range allowed
correctly
Internal memory error
Check and if necessary
EEPr
USB
re-programme
the
parameters function.
In probe error status, the output OUT behaves as set by the
parameters tonE and toFE.
Other Signalling:
Message
Reason
Delay in switching on in progress
od
USB
6.2 - CLEANING
We recommend cleaning of the instrument with a slightly wet cloth
using water and not abrasive cleaners or solvents which may
damage the instrument.
SUPPLY ADAPTER
5,5
78
35
28
TLZ 10
Out
64
min. 15 mm
min. 12 mm
29
71
RECOMMENDED
PANEL CUTOUT
BRACKETS
MAX 12 mm
PANEL + GASKET
34