THS 04

Installation

Function

Output

A : temperature &
humidity output

Power Supply

1 : 4~20mA
6 : 0-10V

1 : 24 VDC15%

38mm

03 : indoor type
04 : duct-mounting

23.9mm
279mm

12mm

M12*1.5

243mm

130.5mm

80mm

80mm

M12*1.5

62mm

THS04

V+
H

V
mA

V
mA

30

Temperature Range
30 : 0~50C

00 Humidity Range
00 : 0~100%

E
Option1
E : none

D
Option2
D:LCD display

INPUT
Measuring range.............temperature: 0~50C ; humidity : 0~100%
Working range ..................temperature: 0~50C ; humidity : 5~95%
OUTPUT
Output ........................................................................ 0-10V ; 3-wire
Display type ...... LCD Module with back light, double line character
Display range .............................. upon request, one decimal place
Height of character ............................................................ 5.56mm
ACCURACY (at 25C)
Temperature ..........................................................................0.5C
Humidity........................................................... 3% RH( 10 ~ 90%)

12mm

THS03

Power
Supply

Output calibration (ZERO & SPAN) adjustment range .....................


.......................................................10% of zero-point and full-range
Response time t90 (at 25C) ...................................................< 20S
ENVIRONMENT
Media measured ...........................................................................air
Working temperature ........................................................... 0~50C
Working humidity .............................................. 0~95 % (non-cond.)
Storage temperature....................................................... -25 ~ 60C
ELECTRICAL REGULATION
Power supply ............................................................. 24VDC 15%
Electrical connection....................................................4P connector
Installation .................................................... indoor / duct-mounting
Protection degree ............................................IP 54 (Sensor: IP 20)
Electrical protection ..............................................polarity protection

24VDC10%

V4P Connector

www.eyc-tech.com

0-10V(3-wire)

Packing ......................................................................... 20 pcs/CTN


Weight .................................................THS03: 119g / THS04: 164g

THS23/24 - OEM
2-wire Temperature & Humidity Transmitter for Indoor / Duct
OEM
APPLICATIONS
Features
2-wire loop design.
Compact design, good look and easy to install.
An economical choice, high C/P ratio.
Foreign-made sensor component with high accuracy and
long-term stability.
OEM type, MOQ:20pcs.
Applications
Monitoring for HVAC process / air conditioning / environmental
ventilation control.
Environmental monitoring for building / factory / clean room / Lab.
Monitoring for storeroom / crisper / agriculture / food industry.
Temperature and humidity measuring in hospital / pharmaceutical
industry / textile industry.

THS 23

Installation

Function

23 : indoor
24 : duct-mounting

Output

Power Supply

A : temperature & humidity output 1 : 4~20mA

1 : 24 VDC15%

30
Temperature
Range

30 : 0~50C

E
Option

E : none

TECHNICAL SHEET
38mm

DIMENSION

13.5mm

23.9mm

12mm

279mm

M12 Thread,
M12 Connector

M12*1.5

243mm

130.5mm
80mm

40mm

80mm

62mm

Output calibration (ZERO & SPAN) adjustment range .................


...................................................10% of zero-point and full-range
Response time t90 (at 25C) ............................................. < 20S

THS24

ENVIRONMENT
Media measured .......................................................................air
Media temperature ...........................................................0~50C
Storage temperature......................................................-25~60C

Upon customers
request

12mm

CONNECTION DIAGRAM
+24 V

PowerSupply

TOUT

mA

HOUT

mA

OUTPUT
Output .................................................................4~20mA ; 2-wire
ACCURACY (at 25C)
Temperature ..................................................................... 0.5C
Humidity........................................................... 3%RH (10~90%)

M12*1.5

THS23

INPUT
Input................................ capacitive humidity sensor & PT 100
Measuring range.........temperature: 0~50C ; humidity : 0~100%
Working range ..............temperature: 0~50C ; humidity : 0~95%

24VDC15 %

TS-504-3P Connector

ELECTRICAL REGULATION
Power supply .......................................................... 24VDC 15%
Electrical connection................................... TS-504-4P connector
Installation ....................................wall-mounting / duct-mounting
Protection degree ....................................... IP 54 (Sensor: IP 20)
Electrical protection ..........................................polarity protection
Certification..............................................................................CE
Housing ...........................................PC fire-proof class (PC-110)
Probe ...............................................PC fire-proof class (PC-110)
Packing ....... ......................................... . ................ 20 pcs / CTN
Weight ..................... ....................... .THS23: 117g / THS24: 162g

FTS04 - OEM
Air Velocity Transmitter for Duct Type
APPLICATIONS
Features
Measuring range :20 m/s.
Output: 4~20 mA / 0~10 VDC.
High stability and repeatabililty.
Smaller tolerance in setting angle.
Applications
HVAC air process control.
Clean rooms and environmental control.
Laminar control.

FTS 04
Installation

20

Range

04 : duct-mounting

Output
1 : 4~20mA
6 : 0-10V

2020 m/s

Power Supply
1 : 24 VDC15%

E
Option

E : none

TECHNICAL SHEET
38mm

DIMENSION

23.9mm

224.65mm

261mm

M12*1.5

12mm
62mm

FTS04

PowerSupply

OUT

GND

V
mA

OUTPUT
Output ................................................ 4~20 mA / 0~10 VDC ; 3-wire
Linear accuracy (at 25C ; 45% ; 1013 mbar) ..................................
.........................................................................3 % of F.S. +0.2m/s
Working range .................................................... 6% ~ 100% of F.S.
Load resistance (current output)........................................... 500
Load resistance (voltage output) .......................................... 10K
Output calibration (ZERO & SPAN) adjustment range .....................
.............................10% for zero-point and full-range (for mA output)
Response time.................reach 90% of ultimate value within 1 sec.
Angular dependence ................................ < 3% of measuring value
.......................................................................(when the angle <10)
ENVIRONMENT
Media measured ........................................................................... air
Media temperature ...............................................................0~50C
Working temperature ............................................................0~50C
Working humidity .............................................................. non-cond.
Storage temperature..........................................................-20~60C
ELECTRICAL REGULATION
Power supply ............................................................. 24 VDC 10%
Current consumption ............................................................150 mA
Overvoltage protection ....................................................... <33VDC
Electrical connection....................................................3P connector

CONNECTION DIAGRAM

V+

INPUT
Measuring range................................................................... 20 m/s

M16 Connector

4-20mA / 0-10V

24VDC

INSTALLATION
Installation ................................................................. duct-mounting
Way to x ................................................................................ ange
Protection degree .....................................................................IP 54
Electrical protection ................................... over-voltage polarity
Certication.................................................................................. CE
Housing ........................................................................PC re-proof
Probe ............................................................................PC re-proof
Probe's head .............................................................stainless Steel
Weight ......................................................................... FTS04: 147g
www.eyc-tech.com