Professional Documents
Culture Documents
2013
50Hz
13KX01E
R410A
History of Technologies
more efficient , more sophisticated
KX2
KX4
KX6
(8~12HP)
Line Up
Contents
Introduction
4~17
Outdoor units
18~33
Indoor units
34~69
Control systems
70~77
78 . 79
80~83
84 . 85
Further information
86~89
R410A
Product Line Up
<Outdoor units>
from 11.2kW up to 136.0kW(24models)
Single use (1 Outdoor unit)
Capacity
Model Code : kW
BTU / h
kcal / h
4HP
11.2
38,200
9,630
5HP
14
47,800
12,040
6HP
15.5
52,900
13,330
8HP
22.4
76,400
19,260
26HP 28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP
73.5
80.0
85.0
90.0
96.0
101.0 106.5 113.0 118.0 123.5 130.0 136.0
250,800 273,000 290,100 307,100 327,600 344,700 363,400 385,600 402,700 421,400 443,600 464,100
63,210 68,800 73,100 77,400 82,560 86,860 91,590 97,180 101,480 106,210 111,800 116,960
4HP
5HP
6HP
FDC112KXEN6
FDC140KXEN6
FDC155KXEN6
1-phase 220-240V
FDC112KXES6
FDC140KXES6
FDC155KXES6
3-phase 380-415V
8HP
10HP
12HP
FDC224KXE6G
FDC280KXE6G
FDC335KXE6G
12HP
14HP
16HP
18HP
FDC335KXE6-K
FDC400KXE6
FDC450KXE6
FDC504KXE6
20HP
20HP
22HP
24HP
FDC560KXE6
FDC560KXE6-K
FDC615KXE6
FDC680KXE6
26HP
28HP
30HP
32HP
34HP
36HP
14+14
14+16
16+16
16+18
18+18
40HP
42HP
44HP
46HP
48HP
20+20
20+22
22+22
22+24
24+24
<Indoor units>
Wide variety of 17 types 89 models
A range of 17 types of exposed or concealed
indoor units, in wide capacities, 89 indoor models.
The best selection of indoor units for
many kinds of rooms and preference can be
available from our full lineup.
Type
Ceiling
Cassette
Duct
Connected
4way
FDT
4way Compact
(600 x 600)
FDTC
2way
FDTW
1way Compact
FDTQ
1way
FDTS
High
Static Pressure
FDU
Low/Middle
Static Pressure
FDUM
Low Static
Pressure
(thin)
FDUT
Compact &
Flexible
FDUH
Wall Mounted
FDK
Ceiling Suspended
FDE
Floor
Standing
2way
FDFW
with casing
FDFL
without casing
FDFU
OA Processing unit
5HP
140
6HP
160
8HP 10HP
224 280
FDU-F
Type
Fresh Air Ventilation and
Heat Exchange unit
250
350
500
800
850
1000
1300
1800
SAF
SAF-DX
R410A
User friendly
LCD panel with light tap operation
introduced as the industry's first
Simple interface with only three buttons
NEW
RC-EX1A
Run / Stop
High power operation
Energy-saving operation
1. Basic operation
All settings done by tapping touch screen panel
Operation mode
Cooling
Fan
Dry
Heating
Auto
2. Main functions
Saving energy
Comfort
Sleep timer
Peak cut timer
Automatic temerature set back
Weekly timer
Set ON/OFF timer by hour
Set ON/OFF timer by clock
Convenience
Service
Outdoor unit
Indoor unit
eco touch
Remote Control
USB
eco touch Remote Control
RC-EX1A Utility Software
R410A
EER in Cooling
COP
4.5
4.0
3.2
4.00
4.00
COP
4.5
4.33
CLASS
4.15
3.71 3.72
4.0
3.36 3.29
3.5
COP in Heating
CLASS
3.6
3.84 3.71 3.84 3.82 3.74 3.75
3.5
3.0
3.0
2.5
2.5
4
10
12
14
16
18
20
HP
10
12
14
16
18
20
HP
(ISO-T1 conditions)
2. Compact Design
4~6HP(KX6)
Volume
1FAN
35% less
Weight
32% less
KX4
H1300 x W970 x D370mm
125kg / 0.47m3
(Harmonic Appearance)
KX6
H845 x W970 x D370mm
85kg / 0.30m3
(FDC112/140/155KXEN6)
2FAN
8~12HP(KX6)
Volume
47% less
Weight
10% less
KX4
H1690 x W1350 x D720mm
245kg / 0.97m3
KX6
H1675 x W1080 x D480mm
221kg / 0.52m3 (FDC224KXE6G)
Heat Exchanger
DC Fan Motor
Compact & High efficiency
KX4
KX6
8~12HP(KX6)
New DC Fan motor
Downsized accumulator
14~48HP(KX6)
DC Fan Motor
Tetrahedral structure of
Heat Exchanger
Double tube
3D-Scroll Compressor
(22,24HP)
R410A
3D Scroll Compressor
Unit start up speed in heating mode drastically improved for lower outdoor temperature operation.
Present scroll
3D scroll
Lower at the
inside
Same height
Higher at the
outside
Fixed scroll
Orbital scroll
2-Dimension compression
Downsizing
High Efficiency
High Endurance
3-Dimension compression
DC Fan Motor
KX6
10
KX4
3. Design Flexibility
Increased indoor unit connection capacity
KX6 series(4~34HP) can connect indoor unit capacity up to
150~200% from 130% of previous models.
If the connection capacity of indoor units is more than 100%,
capacity of each indoor unit may be affected by connection
capacity ratio.
Capacity connection
HP
KX4
5~12
130%
HP
KX6
4~12 150%
14,16
130%
14,16 200%
18~34
130%
18~34 160%
36~48
130%
36~48 130%
FDFL,FDFU and/or FDFW series are connected to the system, the total
connecting capacity of indoor units should not exceed 130%.
KX6 14,16HP
KX4
130% capacity connection
KX6
200% capacity connection
KX6 enable more connectable indoor units (per kW), compared with former model KX4.
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
KX6
KX4
4 5 6
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48 HP
Control Systems
KX6 series offer wide variation of control system and provide the best solution.
[KX6 Control system units with "New" SUPERLINK- ]
Classification
Type
Model
RC-E5
RC-EX1A
RCN-T-36W-E etc.
SC-SL1N-E
SC-SL2NA-E
SC-SL3NA-AE
SC-SL3NA-BE
SC-WGWNA-A
SC-WGWNA-B
SC-BGWNA-A
SC-BGWNA-B
SC-LGWNA-A
1
1
1
16
64
128
128
128(64x2)
128(64x2)
128(64x2)
128(64x2)
96(48x2)
Electric power
calculation
11
R410A
8~12HP(KX6)
14~48HP(KX6)
Max: 10m
Total length:
510 1000m
Outdoor unit
To the
first branch:
max 130m
Indoor unit
Indoor unit
Indoor unit
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
Max: 5m
To the
first branch:
max 130m
Max height
difference
between
indoor units:
4m 18m
Max: 0.4m
Outdoor unit
Indoor unit
Indoor unit
Indoor unit
Furthest
indoor unit:
160m
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
Max height
difference
between
indoor units:
15m 18m
Furthest
indoor unit:
160m
(1)Divide up the refrigerant system into independent refrigeration circuit systems in case required additional refrigerant on site is 50kg or more for
14~24HP and 100kg or more for 26~48HP.
(2)In case indoor unit connection capacity is 130% or more or total piping length is 510m or more, additional charge of refrigerant and oil on site
is required. Refer to our Installation Manual for details.
8~12HP (KX6)
850
Easy
transportation
800
1350mm
12
1350mm
1350mm
Heating
KX6
-20C
+15.5C
KX4
-15C
Cooling
KX6
-15C
-5C
+43C
KX4
-20
-10
0
10
20
30
40
For the capacities under low temperature conditions, refer to technical manual.
KX4
KX6
3-core
2-core
50
KX4
KX6
1000m
1500m
4. Serviceability
Easy Service
Blower
compartment
Mechanical
compartment
13
R410A
Monitoring Function
KX6 series includes new feature to assist with servicing and trouble shooting.
Various data can be monitored through 3-digit or 6-digit display on the outdoor unit PCB.
Detailed fault diagnosis and operation history memory via
7-segment display.
4~6HP
8~48HP
3 Layer Construction
(KX6 <14~48HP>)
Thanks to improvement of
control box structure from
4 to 3 layer construction
and by use of hinged lays,
service and maintenance
has been made much easier
for inverter components.
Compressor
failed
Keeping
operation
KX6 R410A
9.52
22.22
Liquid
piping
Gas piping
ex.10HP
Inverter
Outdoor unit
HP
KX6
Liquid piping Gas piping
4
15.88
5
6
9.52
19.05
8
22.22
10
12
25.4[28.58]
14
16
12.7
18
28.58
20
22
24
26
28
31.8[34.92]
30
15.88
32
34
36
38
40
38.1[34.92]
42
19.05
44
46
48
[ ]: Pipe sizes applicable to European
installations are shown in parentheses.
mm 9.52 12.7 15.88 19.05 22.22 25.4 28.58 31.8 34.92 38.1 44.5 50.8
inch 3/8"
14
1/2"
5/8"
3/4"
7/8"
1"
11/8"
11/4"
13/8"
11/2"
13/4"
2"
Blue Fin
Due to application of blue coated fins for the heat exchanger of
new outdoor unit, corrosion resistance has been improved
compared to current models.
15
R410A
FDUM
NEW
New
FDUM
Duct
Duct
Longer Duct
Ceiling
Keep the same
air flow volume
case1
case2
RC-E5
Setting No.
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
No.9 No.10
E.S.P. button
E.S.P.
10Pa
20Pa
30Pa
40Pa
50Pa
60Pa
70Pa
80Pa
90Pa 100Pa
NEW
FDTW
3
RCN-TW-E
Selected
upper position
Max swing
range
Selected
lower position
* Wireless remote control and RCH-E3 is not applicable to the lndvidual flap
control system and the Flap control system.
16
FDUT
NEW
20mm less!!
2dB(A)
Down
30
1m
Unit
1m
2m
Depth: 520 500mm
Current Model
Current
New
1dB(A)
Down
1.5m
20
1m
29
28
24
10
22
0
Hi
Fan speed
Lo
New Model
[dB(A)]
40
Serviceability
Current
New
5dB(A)
Down
4dB(A)
Down
30
20
Access to control
37
32
10
30
26
0
Hi
Access to control
Current Model
Fan speed
Lo
New Model
NEW
FDTS
For wireless remote control simply attach an additional panel with infrared receiver
on the right side of the main decorative panel.
RCN-TS-E
17
R410A
Outdoor units
Heat pump systems 4, 5, 6hp (11.2kW~15.5kW)
Model No.
FDC112KXEN6
FDC140KXEN6
FDC155KXEN6
FDC112KXES6
FDC140KXES6
FDC155KXES6
The KX6 heat pump 2-pipe systems offer high performance VRF for
Range of operation
Outdoor unit
50
+43C
Height difference
40
30
Indoor unit
difference between
indoor units: 15m
Indoor unit
Cooling
20
Max height
+15.5C
10
0
Heating
-10
-15C
Furthest
indoor unit: 70m
-20
-20C
Specifications
Item
Nominal horse power
Power source
Model
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
mm
Exterior dimensions
HxWxD
kg
Net weight
kg
Refrigerant charge
R410A
dB(A)
Cooling/Heating
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDC112KXEN6
FDC140KXEN6
FDC155KXEN6
FDC112KXES6
FDC140KXES6
FDC155KXES6
4HP
6HP
4HP
15.5
16.3
11.2
12.5
5HP
3 Phase 380-415V, 50Hz
14.0
16.0
6HP
11.2
12.5
5HP
1 Phase 220-240V, 50Hz
14.0
16.0
15.5
16.3
2.80
2.89
13.5-12.4
14.1-12.9
4.17
4.31
20.6-18.9
21.5-19.7
4.71
4.38
23.3-21.3
21.9-20.1
2.80
2.89
4.5-4.1
4.7-4.3
4.17
4.31
6.9-6.3
7.2-6.6
4.71
4.38
7.8-7.1
7.3-6.7
845x970x370
85
87
5.0
52/54
53/55
53/56
52/54
53/55
53/56
9.52(3/8")
15.88(5/8")
80~150
6
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
18
Refrigerant piping
Outdoor unit (HP)
Gas pipe
Liquid pipe
Branch pipes
Header pipe
DIS-22-1G/DIS-180-1G
HEAD6-180-1G
15.88
9.52
Dimensions
All measurements in mm.
36
40
51
L3
L2
100
Intake
L4
Intake
L1
Terminal block
outlet
Service
space
845
110
195
52
27
15
970
190
580
II
II
Open
500
300
Open
150
300
150
200
60
15
15
103
262
Mark
A
B
C
D
E
F
388
Item
Service valve connection (gas side)
Service valve connection (liquid line)
Pipe/cable draw-out port
Drain discharge port
Anchor bolt hole
Cable draw-out port
70
50
20
40
150
38
370
410
50
I
Open
40
60
55
20
60
L1
L2
L3
L4
50
279
242
110
55
50
50
10
195
40
15
50
VIEW A
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts. An anchor
bolt must not protrude more than 15mm.
(3) Where the unit is subject to strong winds, lay it in
such a direction that the blower outlet faces
perpendicularly to the dominant wind direction.
(4) Leave a 1m or larger space above the unit.
(5) A wall in front of the blower outlet must not exceed
the units height.
(6) The unit name plate is attached on the lower right
corner of the front panel.
19
R410A
Outdoor units
Heat pump systems 8, 10, 12hp (22.4kW~33.5kW)
Model No.
FDC224KXE6G
FDC280KXE6G
FDC335KXE6G
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal
for open plan areas.
Indoor unit
Indoor unit
From the first
branch to the
furthest indoor
unit: 90m*
Range of operation
Outdoor unit
Indoor unit
50
+43C
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
40
30
Cooling
20
Max height
difference
between
indoor units:
18m
+15.5C
10
0
Heating
-10
-15C
-20
Furthest
indoor unit: 160m
-20C
* The difference between the longest and the shortest indoor unit piping
from the first branch must be within 40m.
Specifications
Item
Nominal horse power
Power source
Model
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Cooling/Heating
dB(A)
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDC224KXE6G
FDC280KXE6G
FDC335KXE6G
8HP
10HP
3 Phase 380-415V, 50Hz
28.0
31.5
5
8.09
8.21
13.22-12.10
13.41-12.28
1675x1080x480
12HP
22.4
25.0
5.60
6.03
9.25-8.47
9.85-9.02
11.5
59/60
9.52(3/8")
19.05(3/4")
15
9.82
10.12
15.87-14.53
16.36-14.98
224
221
58/58
33.5
37.5
22.22(7/8")
50~150
19
61/61
12.7(1/2")
25.4(1") [28.58(1 1/8")]
22
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
20
Refrigerant piping
Outdoor unit (HP)
Gas pipe
Liquid pipe
Gas pipe
Liquid pipe
8
Furthest indoor unit
=<90m
19.05
22.22
Branch pipes
10
12
22.22
28.58
9.52
Header pipe
12.7
28.58
12.7
DIS-22-1G/DIS-180-1G
HEAD6-180-1G
DIS-371-1G
Dimensions
All measurements in mm.
Intake
L1
L2
L3
L4
L4
Intake
L1
Outlet
Service
space
43
60
120
69
51
L3
L2
69
B
A
G
II
II
Open
Open
1500
300
Open
300
300
300
1080
195
690
54
14
35
159
84
174
84
35
84
159
194
30
701
Item
A
B
C
D
E
54
51
461
421
80
14
141
241
321
361
30
50
105
520
480
19
39
Mark
67
42
989
195
50
19
39
51
55
55
55
20
553
640(8.10HP)
634(12HP)
1675
Terminal block
FDC224KXE6G
FDC280KXE6G
FDC335KXE6G
19.05 (3/4")(Brazing)
22.22 (7/8")(Brazing)
25.4 (1")(Brazing)
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts. An anchor bolt
must not protrude more than 15mm.
(3) Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces perpendicularly
to the dominant wind direction.
(4) Leave a 1m or larger space above the unit.
(5) A wall in front of the blower outlet must not exceed the
units height.
(6) The model name label is attached on the lower right
corner of the front.
(7) Connect the Service valve with local pipe by using the
pipe of the attachment.(Gas side only)
(8) Mark shows the connecting position of the local
pipe.(Gas side only)
21
R410A
Outdoor units
Heat pump systems 14, 16hp (40.0kW~45.0kW)
Model No.
FDC400KXE6
FDC450KXE6
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal
for open plan areas.
Outdoor unit
Range of operation
Indoor unit
Indoor unit
Indoor unit
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
50
+43C
40
*2
30
Max height
difference
between
indoor units:
18m
Cooling
20
+15.5C
10
0
Heating
Furthest
indoor unit: 160m
-10
-15C
-20
-20C
*1 The difference between the longest and the shortest indoor unit piping
from the first branch must be within 40m.
*2 Height difference up to 100m is possible with High Head series.
Please refer to page 80.
Specifications
Item
Nominal horse power
Power source
Model
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Cooling/Heating
dB(A)
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDC400KXE6
FDC450KXE6
14HP
16HP
3 Phase 380-415V, 50Hz
40.0
45.0
45.0
50.0
8
11.27
11.73
18.4-16.9
19.6-17.9
12.97
13.10
21.1-19.3
21.7-19.9
1690x1350x720
334
11.5
59.5/60
62.5/62.5
12.7(1/2")
28.58(1 1/8")
50~200
53
60
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
22
Dimensions
All measurements in mm.
22
120
296.7
174
720
240
295
342
235
22
140
352 158
530
148
410
C (right)
6
86.1
104.9
D (front)
95
Item
Service valve connection (gas side)
Service valve connection (liquid line)
Refrigerant pipe draw-out port
Power cable draw-in port
Anchor bolt hole
Drain hose hole
Drain discharge port
Oil-equalising pipe joint
Sling holes for haulage or hoisting
D (right)
90
44.7
86.5
20
Instruction plate
172
C (rear)
C (front)
220 180
88
50
M10 x 4 places
45 x 3 places
20 x 6 places
3/8 flare
180 x 44.7
180 214
Intake
Installation example
For refrigerant piping, please
refer to the unit specifications.
550
L3
K
B
A
166
169
211
259
291.6
84
L2
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
10
200
100
300
10
Open
1500
Wall
height H2
Wall
height H3
L4
Intake
Intake
Service
space
L1
A
B
C
D
F
G
H
K*
L
Air intake
F
For dimensions of anchor bolt hole
1690
797.8
Mark
Terminal block
for power cable
connection
80.5
71
57
85
80
D (left)
594
232
19
58.5
647
682
175
Signal wire
terminal block
232
D(lower)
185
7-segment display
inspection port
Drain pipe
74.5
1350
126.2
720
I F
250
175
172
234
75
142.5
19
141
95
140.5
726
K
B
F I
58.5
Rear
850
1000
85
101
250
175
Dimensions of refrigerant
pipe connection (plan)
Intake
Wall height H4
Wall height H1
Installation space
2m overhead clearance required
No restrictions No restrictions
1000
No restrictions
No restrictions
Installation example
Wall height
H3
Wall height
H2
L3
L2
L5
L6
L1 (Unit front side)
Wall height
H2
L4
Wall height
H4
Notes:
(1) The unit must be fixed with anchor bolts.
(2) Leave a 2m or larger space above the unit.
(3) The unit name plate is attached on the lower right corner of
the front panel.
(4) The ports for refrigerant pipe and power cable penetrations
are covered with half-blanks. Please cut off a half-blank with
nippers in using these ports.
(5) Use a 88 port for refrigerant pipe connection.
(6) Anchor holes marked L J (four holes for M10) are for a
renewal installation.
(7) The oil-equalising pipe K should be used when outdoor units
are used in combination. (For 14,16Hp only)
Dimensions
L1
500
Open
L2
10
200
L3
100
300
L4
10
Open
L5
400
L6
400
H1
1500
No restrictions
H2
H3
H4
No restrictions No restrictions
1000
No restrictions
No restrictions No restrictions
23
R410A
Outdoor units
Heat pump systems 18, 20, 22, 24hp (50.4kW~68.0kW)
Model No.
FDC504KXE6
FDC560KXE6
FDC615KXE6
FDC680KXE6
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal
for open plan areas.
Indoor unit
Indoor unit
Indoor unit
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
Range of operation
50
+43C
40
*2
Max height
difference
between
indoor units:
18m
30
Cooling
20
+15.5C
10
0
Heating
Furthest
indoor unit: 160m
-10
-15C
-20
-20C
*1 The difference between the longest and the shortest indoor unit piping
from the first branch must be within 40m.
*2 Height difference up to 100m is possible with High Head series.
Please refer to page 80.
Specifications
Item
Nominal horse power
Power source
Model
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Cooling/Heating
dB(A)
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDC504KXE6
FDC560KXE6
FDC615KXE6
FDC680KXE6
18HP
20HP
22HP
24HP
61.5
69.0
68.0
73.0
20.37
18.48
33.1-30.3
30.7-28.1
24.98
19.08
40.3-36.9
31.6-29.0
56.0
63.0
14.73
15.12
24.1-22.0
25.2-23.1
16.79
16.79
27.4-25.1
28.0-25.7
2048x1350x720
356
375
11.5
61.5/62.0
63.0/63.5
64.5/64.0
65.0/65.0
65
72
12.7(1/2")
28.58(1 1/8")
50~160
53
59
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
24
Dimensions
All measurements in mm.
234
75
142.5
19
120
22
80.5
71
296.7
85
Air intake
I
I F J
F
For dimensions of anchor bolt hole
J
174
720
240
295
57
594
232
352 158
530
148
410
342
235
22
I F
232
D(lower)
185
1350
2048
1155.8
126.2
720
F I
74.5
140
141
95
140.5
726
58.5
19
250
175
647
Rear
58.5
Dimensions of refrigerant
pipe connection (plan)
850
1000
85
101
250
175
Mark
A
B
C
D
F
G
H
K
L
Instruction plate
D (front)
104.9
6
86.1
95
Item
Service valve connection (gas side)
Service valve connection (liquid line)
Refrigerant pipe draw-out port
Power cable draw-in port
Anchor bolt hole
Drain hose hole
Drain discharge port
Oil-equalising pipe joint
Sling holes for haulage or hoisting
44.7
172
166
169
211
259
291.6
682
172
Terminal block
for power cable
connection
D (right)
90
86.5
20
80
C (rear)
220 180
Intake
Installation example
For refrigerant piping, please
refer to the unit specifications.
100
50
M10 x 4 places
45 x 3 places
20 x 6 places
9.52 flare
180 x 44.7
550
L2
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
10
200
100
300
10
Open
1500
180 214
L3
D (left)
84
175
Signal wire
terminal block
C (right)
C (front)
Wall
height H2
Service
space
Wall
height H3
L4
Intake
Intake
L1
K
B
A
7-segment display
inspection port
Drain pipe
Intake
Wall height H4
Wall height H1
Installation space
2m overhead clearance required
No restrictions No restrictions
1000
No restrictions
No restrictions
Notes:
(1) The unit must be fixed with anchor bolts.
(2) Leave a 2m or larger space above the unit.
(3) The unit name plate is attached on the lower right corner of
the front panel.
(4) The ports for refrigerant pipe and power cable penetrations
are covered with half-blanks. Please cut off a half-blank with
nippers in using these ports.
(5) Use a 88 port for refrigerant pipe connection.
(6) Anchor holes marked L J (four holes for M10) are for a
renewal installation.
(7) The oil-equalising pipe K should be used when outdoor units
are used in combination.
25
R410A
Outdoor units
Heat pump combination systems
26, 28, 30, 32hp (73.5kW~90.0kW)
Model No.
FDC735KXE6 (FDC335-K+FDC400)
FDC800KXE6 (FDC400x2)
FDC850KXE6 (FDC400+FDC450)
FDC900KXE6 (FDC450x2)
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal
for open plan areas.
Outdoor unit
Indoor unit
Indoor unit
Indoor unit
Range of operation
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
50
+43C
40
*2
30
Max height
difference
between
indoor units:
18m
20
Cooling
+15.5C
10
0
Heating
-10
Furthest
indoor unit: 160m
-15C
-20
*1 The difference between the longest and the shortest indoor unit piping
-20C
Specifications
Item
Model
Combination (FDC)
Nominal horse power
Power source
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDC735KXE6
335KXE6-K
400KXE6
26HP
73.5
82.5
20.21
20.66
32.9-30.2
34.4-31.4
78
FDC800KXE6
FDC850KXE6
400KXE6
400KXE6
400KXE6
450KXE6
28HP
30HP
3 Phase 380-415V, 50Hz
80.0
85.0
90.0
95.0
16
22.54
24.24
23.46
24.83
36.8-33.8
39.5-36.2
39.2-35.8
41.3-37.8
1690x2700x720
334x2
11.5x2
15.88(5/8")
31.8(1 1/4") [34.92(1 3/8")]
50~160
80
80
FDC900KXE6
450KXE6
450KXE6
32HP
90.0
100.0
25.94
26.20
42.2-38.6
43.4-39.8
80
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
26
Dimensions
All measurements in mm.
A
B
C
D
F
G
H
K
L
22
120
296.7
174
720
240
295
342
235
22
352 158
530
148
410
140
C (right)
Instruction plate
D (front)
104.9
6
86.1
Item
Service valve connection (gas side)
Service valve connection (liquid line)
Refrigerant pipe draw-out port
Power cable draw-in port
Anchor bolt hole
Drain hose hole
Drain discharge port
Oil-equalising pipe joint
Sling holes for haulage or hoisting
88
50
M10 x 4 places
45 x 3 places
20 x 6 places
3/8" flare
180 x 44.7
172
C (rear)
C (front)
44.7
K
B
A
166
169
211
259
291.6
84
Air intake
95
90
D (right)
86.5
20
1690
797.8
Mark
Terminal block
for power cable
connection
80.5
71
594
232
85
80
D (left)
57
19
58.5
647
682
175
Signal wire
terminal block
232
D(lower)
185
7-segment display
inspection port
Drain pipe
I F
74.5
1350
126.2
720
250
175
172
234
75
142.5
19
141
95
140.5
726
K
B
F I
58.5
Rear
850
1000
85
101
250
175
Dimensions of refrigerant
pipe connection (plan)
220 180
550
180 214
Notes:
(1) The unit must be fixed with anchor bolts.
(2) Leave a 2m or larger space above the unit.
(3) The unit name plate is attached on the lower right corner of
the front panel.
(4) The ports for refrigerant pipe and power cable penetrations
are covered with half-blanks. Please cut off a half-blank with
nippers in using these ports.
(5) Use a 88 port for refrigerant pipe connection.
(6) Anchor holes marked L J (four holes for M10) are for a
renewal installation.
(7) The oil-equalising pipe K should be used when outdoor units
are used in combination.
27
R410A
Outdoor units
Heat pump combination systems
34, 36, 38, 40, 42, 44, 46, 48hp (96.0kW~136.0kW)
Nominal Cooling Capacity
96.0kW
101.0kW
106.5kW
113.0kW
118.0kW
123.5kW
130.0kW
136.0kW
Model No.
FDC960KXE6 (FDC450+FDC504)
FDC1010KXE6 (FDC504x2)
FDC1065KXE6 (FDC504+FDC560)
FDC1130KXE6 (FDC560x2)
FDC1180KXE6 (FDC560-K+FDC615)
FDC1235KXE6 (FDC615x2)
FDC1300KXE6 (FDC615+FDC680)
FDC1360KXE6 (FDC680x2)
The KX6 heat pump 2-pipe systems offer high performance VRF for applications that
require either cooling only or heating only, ideal for open plan areas.
Connect
up to 80 indoor units/up to 130% (960KXE6:160%) capacity.
Outdoor unit
50
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
Indoor unit
+43C
40
*2
30
Max height
difference
between
indoor units:
18m
Indoor unit
Range of operation
Indoor unit
20
Cooling
+15.5C
10
0
Heating
-10
Furthest
indoor unit: 160m
-15C
-20
-20C
*1 The difference between the longest and the shortest indoor unit piping
from the first branch must be within 40m.
Specifications
Item
Model
Combination (FDC)
Nominal horse power
Power source
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
504KXE6
504KXE6
36HP
504KXE6
560KXE6
38HP
96.0
108.0
101.0
113.0
106.5
119.5
27.70
28.22
45.2-41.3
46.9-43.0
29.46
30.24
48.2-44.0
50.4-46.2
31.52
31.91
51.5-47.1
53.2-48.8
334+356
560KXE6
560KXE6-K
560KXE6
615KXE6
40HP
42HP
3 Phase 380-415V, 50Hz
113.0
118.0
127.0
132.0
16
33.58
37.16
33.58
35.27
54.8-50.2
60.5-55.4
56.0-51.4
58.7-53.8
2048x2700x720
615KXE6
615KXE6
44HP
615KXE6
680KXE6
46HP
680KXE6
680KXE6
48HP
123.5
138.0
130.0
142.0
136.0
146.0
40.74
36.96
66.2-60.6
61.4-56.2
45.35
37.56
73.4-67.2
62.3-57.1
49.96
38.16
80.6-73.8
63.2-58.0
356x2
375x2
11.5x2
15.88(5/8")
50~160
19.05(3/4")
34.92(1 3/8")
50~130
80
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
28
Dimensions
All measurements in mm.
234
75
142.5
19
80.5
71
Air intake
174
720
352 158
530
148
410
342
235
22
85
240
295
57
594
232
296.7
120
22
232
D(lower)
185
1350
2048
1155.8
126.2
720
I F
74.5
140
141
95
140.5
726
58.5
19
F I
250
175
647
Rear
58.5
Dimensions of refrigerant
pipe connection (plan)
850
1000
85
101
250
175
D (left)
Mark
A
B
C
D
F
G
H
K
L
80
Instruction plate
D (front)
104.9
6
86.1
Item
Service valve connection (gas side)
Service valve connection (liquid line)
Refrigerant pipe draw-out port
Power cable draw-in port
Anchor bolt hole
Drain hose hole
Drain discharge port
Oil-equalising pipe joint
Sling holes for haulage or hoisting
100
50
M10 x 4 places
45 x 3 places
20 x 6 places
9.52 flare
180 x 44.7
44.7
172
166
169
211
259
291.6
682
C (rear)
172
Terminal block
for power cable
connection
84
175
Signal wire
terminal block
C (right)
C (front)
95
90
D (right)
86.5
20
K
B
A
7-segment display
inspection port
Drain pipe
220 180
550
180 214
Notes:
(1) The unit must be fixed with anchor bolts.
(2) Leave a 2m or larger space above the unit.
(3) The unit name plate is attached on the lower right corner of
the front panel.
(4) The ports for refrigerant pipe and power cable penetrations
are covered with half-blanks. Please cut off a half-blank with
nippers in using these ports.
(5) Use a 88 port for refrigerant pipe connection.
(6) Anchor holes marked L J (four holes for M10) are for a
renewal installation.
(7) The oil-equalising pipe K should be used when outdoor units
are used in combination.
29
R410A
refrigerant piping
Installation of Interconnecting Pipework
Mitsubishi KX6 equipment is manufactured to
the highest standards of quality and reliability.
It is imperative the method of installation and
the materials used are also to high standards,
to ensure trouble free operation and long term
reliability.
The interconnecting pipework must be installed
by a competent and trained engineer.
Refrigeration quality copper tube must be used,
soft copper coils or half-hard straight lengths.
The refrigeration quality tube must be soft
drawn seamless high grade copper pipe. The
copper tube must be selected taking into
account the higher operating pressures of
R410A refrigerant, and that high pressures will
occur throughout the system because of the
reverse cycle operation. All pipework material
used should be EN12735 European standard.
HEAD8-371-1G
Liquid pipe
90
90
56
56
36
36
36
36
Gas pipe
56
30
56
36
36
36
112
112
112
refrigerant piping
Outdoor unit (HP)
Liquid pipe
Gas pipe
Liquid pipe
Gas pipe
10
12
14
16
18
9.52
12.7
19.05 22.22
28.58
22.22
12.7
Branch pipes
20
22
26
28
30
32
34
36
38
15.88
40
42
44
46
48
19.05
34.92
15.88
19.05
28.58
22.22
34.92
mm
inch
9.52
3/8"
mm
inch
28.58 11/8"
11/4"
12.7
1/2"
31.8
15.88
5/8"
34.92 13/8"
19.05
3/4"
38.1
11/2"
22.22
7/8"
44.5
13/4"
25.4
1"
50.8
2"
Header pipe
Horizontally
Good
Floor
DIS-22-1G/DIS-180-1G
HEAD6-180-1G
No
Good
Vertically
Floor
Floor
No
DIS-371-1G/DIS-540-2G
Floor
DOS-2A-1G
112
112
90
90
90
140
Outdoor unit
2 units (for 735~1360)
HEAD8-540-2G
112
140
140
112
90
90
90
140
140
140
Total capacity of
indoor units
~179
180~370
371~539
540~
Header set
Model
HEAD4-22-1G
HEAD6-180-1G
HEAD8-371-1G
HEAD8-540-2G
Branches
Max 4 branches
Max 6 branches
Max 8 branches
Max 8 branches
31
R410A
Outdoor unit
Grounding
wire
[2 cores]
A
B
C
Circuit breaker
for cabling
Earth leakage breaker
Indoor unit
D
R
CAUTION
If the earth leakage breaker is exclusively for ground fault protection, then you will need to install a circuit breaker for wiring work.
Electrical
component box
Outdoor unit power supply terminal block
32
0.75mm2
YES
YES
1.25mm2
YES
NO
A1
B1
A1
A1
B1
B1
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
A1B1 A2B2
A1B1 A2B2
A1B1 A2B2
A1B1 A2B2
Indoor unit
Indoor unit
A
B
A
B
Indoor unit
Indoor unit
A
B
A
B
Signal line
Network connector
Refrigerant pipe
(a) The maximum number of indoor units that can be connected in a system is 128 and it is possible to configure
outdoor units and/or indoor units as an outdoor or indoor unit group connected with each other with two wires.
(b) The signal wires can also be connected using the method shown below.
(3) The signal lines can also be connected using the method shown below.
Important
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
Indoor unit
Outdoor unit
Indoor unit
Length (m)
100 to 200
To 300
To 400
To 600
Wire size
0.5mm2 x 2 core
0.75mm2 x 2 core
1.25mm2 x 2 core
2.0mm2 x 2 core
Remote control
A
Indoor unit
A
Indoor unit
Indoor unit
33
R410A
Indoor units
Ceiling Cassette -4wayFDT
Model No.
FDT28KXE6F
FDT36KXE6F
FDT45KXE6F
FDT56KXE6F
FDT71KXE6F
RC-EX1A
RC-E5
RCH-E3
Wireless
FDT90KXE6F
FDT112KXE6F
FDT140KXE6F
FDT160KXE6F
RCN-T-36W-E
KX4
270mm
365mm
246
298
mm
KX4
mm
9%
FDT28~71
FDT112~160
reduction!!
KX6
18%
reduction!!
Selection of flap
position is possible.
Individual flaps can
be set at different
angles.
is not applicable to the
*RCH-E3
Individual flap control system
Upper
position
Movable
range
Lower
position
Specifications
Item
Model FDT28KXE6F
Nominal cooling capacity kW
2.8
Nominal heating capacity kW
3.2
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow
CMM
Outside air intake
Panel
Air filter, Qty
Remote control(option)
Liquid line:6.35(1/4")
Installation data
Refrigerant piping size mm(in) Gas line:9.52(3/8")
FDT36KXE6F
FDT45KXE6F
FDT56KXE6F
3.6
4.0
4.5
5.0
5.6
6.3
FDT71KXE6F
7.1
8.0
1 Phase 220-240V, 50Hz
0.04-0.04
0.08-0.08
0.04-0.04
0.08-0.08
0.03-0.03
0.03-0.03
Hi:33 Me:31 Lo:30
11.2
12.5
Unit:246x840x840 Panel:35x950x950
Unit:22 Panel:5.5
9.0
10.0
16.0
18.0
0.15-0.15
0.15-0.15
Hi:42 Me:40 Lo:37 Hi:43 Me:41 Lo:38
Unit:298x840x840 Panel:35x950x950
Unit:24 Panel:5.5
14.0
16.0
Unit:27 Panel:5.5
Hi:27 Me:24 Lo:20
Possible
T-PSA-3BW-E
Pocket Plastic net x1 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-T-36W-E
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDT28/36/45 37dB(A), FDT56 39dB(A), FDT71 46dB(A), FDT90/112/140/160 51dB(A). Air flow: FDT28/36/45/56 20CMM, FDT71 28CMM, FDT90/112/140/160 37CMM.
34
Dimensions
All measurements in mm.
35
R410A
Wireless
RC-EX1A
(dB) 36
(dB) 36
35
34
33
32
31
30
29
28
27
26
25
32
dB
32
dB
30
dB
KX4
(Cooling/Heating)
KX6
(Cooling)
KX6
(Heating)
OA Spacer
OA
Panel
Joint Duct
KX4
(Cooling/Heating)
36
dB
34
dB
31
dB
KX6
(Cooling)
KX6
(Heating)
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
39
dB
KX6
(Heating)
5dB
Down
8dB
Down
34
dB
31
dB
KX4
(Cooling/Heating)
FDTC45KX
KX6
(Cooling)
FDTC36KX
2dB
Down
5dB
Down
KX4
(Cooling/Heating)
34
dB
31
dB
(dB) 40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
300mm
3dB
Down
34
dB
FDTC22KX, 28KX
(dB) 40
Ceiling OA
surface
35
34
33
32
31
30
29
28
27
26
25
2dB
Down
KX6
(Cooling)
KX6
(Heating)
FDTC56KX
Upper
position
Movable
range
Lower
position
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure Cooling
dB(A)
level
Heating
FDTC22KXE6F
FDTC28KXE6F
FDTC36KXE6F
FDTC45KXE6F
FDTC56KXE6F
2.2
2.5
2.8
3.2
3.6
4.0
1 Phase 220-240V, 50Hz
4.5
5.0
5.6
6.3
0.03-0.03
0.03-0.03
Hi:35 Me:33 Lo:30
Hi:35 Me:33 Lo:32
Exterior dimensions
mm
HxWxD
Net weight
0.05-0.05
0.05-0.05
Hi:38 Me:36 Lo:31
Hi:38 Me:36 Lo:34
Unit:248x570x570 Panel:35x700x700
kg
Cooling
Air flow
CMM
Heating
Outside air intake
Panel
Air filter, Qty
Remote control(option)
Unit:14 Panel:3.5
Hi:9.5 Me:8.5 Lo:7
Hi:9.5 Me:8.5 Lo:8
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Unit:15 Panel:3.5
Hi:10 Me:9 Lo:7
Hi:11 Me:9 Lo:7
Hi:10 Me:9 Lo:8
Hi:11 Me:9 Lo:8
Not possible
TC-PSA-25W-E
Pocket Plastic net x1 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TC-24W-ER
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDTC22/28 44dB(A), FDTC36 46dB(A), FDTC45 48dB(A), FDTC56 49dB(A). Air flow: FDTC22/28 12CMM, FDTC36 13CMM, FDTC45 15CMM. FDTC56 16CMM.
36
Dimensions
All measurements in mm.
37
R410A
FDTW28~71
FDTW90KXE6F
FDTW112KXE6F
FDTW140KXE6F
RCN-TW-E
FDTW90~140
750mm Drain Pump
Flexible hose
750mm
Installation workability
Transparent
access hole to
drain pan
Drainage spout
Drainage flow test can be
done easily by use of this
drainage spout.
invisible
Cleaning
Cleaning
not required
required
Specifications
A circumscribes
circle is visible
invisible
Item
Model
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
FDTW28KXE6F
FDTW45KXE6F
FDTW56KXE6F
FDTW71KXE6F
FDTW90KXE6F
FDTW112KXE6F
FDTW140KXE6F
2.8
3.2
4.5
5.0
5.6
6.3
7.1
8.0
1 Phase 220-240V, 50Hz
0.14-0.14
0.14-0.14
9.0
10.0
11.2
12.5
14.0
16.0
Net weight
kg
Air flow
CMM
Outside air intake
Panel
Air filter, Qty
Remote control(option)
Unit:20 Panel:8.5
0.09-0.09
0.09-0.09
0.10-0.10
0.10-0.10
Hi:38 Me:34 Lo:31
Unit:325x820x620 Panel:20x1120x680
Liquid line:6.35(1/4")
Installation data
Refrigerant piping size mm(in) Gas line:9.52(3/8")
Unit:21 Panel:8.5
Hi:12 Me:10 Lo:9
0.19-0.19
0.19-0.19
Hi:45 Me:41 Lo:37
Unit:325x1535x620 Panel:20x1835x680
Unit:23 Panel:8.5
Unit:35 Panel:13
Hi:27 Me:23 Lo:20
Possible
TW-PSA-26W-E
Pocket Plastic net x2 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TW-E
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
TW-PSA-46W-E
Pocket Plastic net x3 (Washable)
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDTW28/45/56/71 42dB(A), FDTW90/112/140 48dB(A). Air flow: FDTW28/45/56/71 14.5CMM, FDTW90/112/140 31CMM.
38
Dimensions
All measurements in mm.
39
R410A
FDTS45KXE6F
FDTS71KXE6F
Wireless
RCN-TS-E
Compact design
Flexible hose
600mm
220mm
Specifications
Item
Model
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
FDTS45KXE6F
FDTS71KXE6F
4.5
5.0
7.1
8.0
1 Phase 220-240V, 50Hz
0.04
0.04
Hi:40 Me:38 Lo:35
0.09
0.09
Hi:46 Me:41 Lo:36
Unit:220x1150x565 Panel:35x1250x650
Net weight
kg
Air flow
CMM
Outside air intake
Panel
Air filter, Qty
Remote control(option)
Unit:27 Panel:5
Hi:12 Me:11 Lo:9.5
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Unit:28 Panel:5
Hi:15 Me:12 Lo:9.5
Possible
TS-PSA-3AW-E
Pocket Plastic net x2 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TS-E
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDTS45 42dB(A), FDTS71 49dB(A). Air flow: FDTS45 13CMM, FDTS71 17CMM.
40
Dimensions
All measurements in mm.
41
R410A
Wired
RCN-KIT3-E
Compact design
35
63
285
Fresh air
opening
for ducting
(Knock out)
250
295~325
210
600 or less
Max.Drain up
Holes for
tapping screws
Specifications
Model
Item
FDTQ22KXE6F
FDTQ28KXE6F
FDTQ36KXE6F
Direct blow panel
Duct panel
Direct blow panel
Duct panel
Direct blow panel
Duct panel
Panel Name
Panel mode (Option)
TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER
Nominal cooling capacity kW
2.2
2.8
3.6
Nominal heating capacity kW
2.5
3.2
4.0
Power source
1 Phase 220-240V, 50Hz
Cooling
0.05-0.07
0.05-0.07
0.05-0.07
Power
consumption Heating kW
0.05-0.07
0.05-0.07
0.05-0.07
Sound pressure level dB(A)
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
250x570x570
250x570x570
250x570x570
Exterior dimensions Unit
mm
HxWxD
35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650
Panel
Net weight
kg Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3
Air flow
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
CMM
Outside air intake
Possible
Air filter, Qty
Pocket Plastic net x1 (Washable)
Remote control(option)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDTQ22/38/36 45dB(A). Air flow: FDTQ22/38/36 8CMM.
42
Dimensions
All measurements in mm.
Direct blow panel (TQ-PSA-15W-E)
Dimension Table
model
Unit:mm
TQ-PSA-15W-E
625
514
650
580
TQ-PSB-15W-E
780
514
650
580
Dimension Table
model
Unit:mm
QR-PNA-14W-ER
625
650
580
QR-PNB-14W-ER
780
650
580
43
R410A
RCN-KIT3-E
Thin design
RCH-E3
Wireless
Duct
RC-E5
RC-EX1A
FDU56KXE6F
FDU71KXE6F
FDU90KXE6F
FDU112KXE6F
FDU140KXE6F
FDU160KXE6F
Duct
Current
New
297
350
280
280
Current
New
40
63
63
34
34
54
FDU71KXE6F
FDU112/140KXE6F
17mm less!!
70mm less!!
Reduction of weight
Longer Duct
Ceiling
Keep the same
air flow volume
case1
FDU71KXE6F
FDU90KXE6F
FDU112/140KXE6F
case2
Setting No.
No.8
E.S.P.
80Pa
10~130Pa
10~200Pa
Net weight
kg
Air flow (Standard) CMM
External Static pressure Pa
Outside air intake
Air filter, Qty
Remote control(option)
Installation data
Refrigerant piping size mm(in)
10
15
20
Current
FDU90KXE6F
FDU112KXE6F
FDU140KXE6F
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
12dB(A) less!!
New
FDU45KXE6F
FDU56KXE6F
FDU71KXE6F
4.5
5.0
5.6
6.3
7.1
8.0
0.10-0.10/0.10
0.10-0.10/0.10
Hi:32 Me:29 Lo:26
280x750x635
29
Hi:10 Me:9 Lo:8
200 (at 13CMM)
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
6kg less!!
29kg less!!
9kg less!!
FDU90KXE6F
FDU112KXE6F
9.0
11.2
10.0
12.5
1 Phase 220-240V, 50Hz
0.24-0.25/0.24
0.31-0.32/0.31
0.24-0.25/0.24
0.31-0.32/0.32
Hi:33 Me:29 Lo:25
Hi:38 Me:36 Lo:30
280x950x635
25
30
New
37
38
39
25
30
29
35
40 dB(A)
Lo mode
12dB(A) less!!
8dB(A) less!!
10dB(A) less!!
FDU140KXE6F
FDU160KXE6F
14.0
16.0
16.0
18.0
0.35-0.36/0.35
0.35-0.36/0.35
Hi:40 Me:34 Lo:29
0.42-0.43/0.42
0.42-0.43/0.42
Hi:40 Me:35 Lo:30
280x1370x740
34
Hi:19 Me:15 Lo:10
Hi:28 Me:25 Lo:19
200 (at 24CMM)
200 (at 36CMM)
Possible
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
54
Hi:32 Me:26 Lo:20
200 (at 39CMM)
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static
pressure of indoor unit is 60Pa.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. Powerful-Hi can be selected. Sound pressure level: FDU45/56 37dB(A), FDU71/90 38dB(A), FDU112 44dB(A), FDU140 45dB(A),FDU160 47dB(A). Air flow: FDU45/56 13CMM, FDU71/90 24CMM, FDU112 36CMM, FDU140 39CMM,
FDU160 48CMM.
44
Dimensions
All measurements in mm.
FDU45KXE6F, 56KXE6F
FDU71KXE6F, 90KXE6F
45
R410A
RC-EX1A
RC-E5
RCH-E3
Wireless
RCN-KIT3-E
Fan motor
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow (Standard) CMM
External Static pressure Pa
Outside air intake
Air filter, Qty
Remote control(option)
Installation data
Refrigerant piping size mm(in)
FDU224KXE6F
FDU280KXE6F
22.4
25.0
28.0
31.5
1 Phase 220-240V, 50Hz
0.94-1.03
0.86-0.90
Hi:51
0.96-1.05
0.88-0.96
Hi:52
360x1570x830
92
Hi:51
Hi:68
200
Possible(on Return duct)
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:9.52(3/8")
Gas line:19.05(3/4")
Liquid line:9.52(3/8")
Gas line:22.22(7/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static
pressure of indoor unit is 100Pa.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. Values of sound pressure level become increased 5dB(A), when external static pressure is 200Pa (factory setting).
4. Values of air flow volume are those at external static pressure 200Pa (factory setting).
46
Dimensions
All measurements in mm.
VIEW
VIEW
47
R410A
NE
FDUM71KXE6F
FDUM90KXE6F
FDUM112KXE6F
FDUM140KXE6F
FDUM160KXE6F
Wireless
NEW
Current FDUM
dB(A)
22/28/36
RCN-KIT3-E
45/56
71
90
112
140
26
26
25
25
30
29
28
29
29
30
32
33
Improvement
RCH-E3
Thin design
Air flow sound was reduced by new fan and casing design.
Refrigerant flow sound was decreased by advanced refrigerant distributor design.
Indoor model name
RC-E5
RC-EX1A
70mm less
H 350
H 280
FDUM112/140KXE6F
19mm less
Pipe
Fan unit
Unit
Maintenance
hole
H 299
H 280
FDUM22~90KXE6F
Service
space
(mm)
Specifications
Model FDUM22KXE6F FDUM28KXE6F FDUM36KXE6F FDUM45KXE6F FDUM56KXE6F FDUM71KXE6F FDUM90KXE6F FDUM112KXE6F FDUM140KXE6F FDUM160KXE6F
Item
Nominal cooling capacity kW
2.2
2.8
3.6
4.5
5.6
7.1
9.0
11.2
14.0
16.0
Nominal heating capacity kW
2.5
3.2
4.0
5.0
6.3
8.0
10.0
12.5
16.0
18.0
Power source
1 Phase 220-240V, 50Hz
Cooling
0.29-0.29
0.45-0.45
0.10-0.10
0.20-0.20
0.33-0.33
Power
consumption Heating kW
0.29-0.29
0.45-0.45
0.10-0.10
0.20-0.20
0.33-0.33
Hi:32 Me:29 Lo:26
Hi:38 Me:36 Lo:30 Hi:40 Me:34 Lo:29 Hi:40 Me:35 Lo:30
Sound pressure level dB(A)
Hi:33 Me:29 Lo:25
Exterior dimensions
mm
HxWxD
Net weight
Air flow
External
Static pressure
kg
CMM
29
Hi:10 Me:9 Lo:8
34
Hi:19 Me:15 Lo:10
54
Hi:28 Me:25 Lo:19 Hi:32 Me:26 Lo:20 Hi:35 Me:28 Lo:22
Pa
100(at 13CMM)
100
(at 24CMM)
100
(at 36CMM)
100
(at 39CMM)
100
(at 48CMM)
Possible
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static
pressure of indoor unit is 35Pa(22/28/36/45/56/71/90), 60Pa(112/140/160).
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDUM22/28/36/45/56 37dB(A), FDUM71/90 38dB(A), FDUM112 44dB(A), FDUM140 45dB(A), FDUM160 47dB(A). Air flow: FDUM22/28/36/45/56 13CMM, FDUM71/90 24CMM,
FDUM112 36CMM, FDUM140 39CMM, FDUM160 48CMM.
48
Dimensions
All measurements in mm.
FDUM71KXE6F, 90KXE6F
49
R410A
FDUT22KXE6F-E
FDUT28KXE6F-E
FDUT36KXE6F-E
FDUT45KXE6F-E
FDUT56KXE6F-E
FDUT71KXE6F-E
RC-EX1A
RC-E5
RCH-E3
Wireless
RCN-KIT3-E
Expansion of lineup
New
(2) Regarding pipe length (150m or more is required) and temperature condition (the lowest is 10C) in the cooling operation etc. , please refer to our technical manual.
Option
Item
Contents
for FDUT15/22/28/36KXE6F-E
for FDUT45/56KXE6F-E
for FDUT71KXE6F-E
UT-SAT1EF
UT-SAT2EF
UT-SAT3EF
2+3
UT-FL1EF
UT-FL2EF
UT-FL3EF
Specifications
Item
Model FDUT15KXE6F-E
Nominal cooling capacity kW
1.5
Nominal heating capacity kW
1.7
Power source
Cooling
0.06-0.06/0.06
Power
consumption Heating kW
0.06-0.06/0.06
Sound pressure level 1 dB(A) Hi:28 Me:26 Lo:22
Sound pressure level 2 dB(A) Hi:32 Me:29 Lo:25
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow (Standard) CMM
External Static pressure Pa
Outside air intake
Suction guard(Air filter)
Remote control(option)
Installation data
Refrigerant piping size mm(in)
FDUT22KXE6F-E
FDUT28KXE6F-E
FDUT36KXE6F-E
FDUT45KXE6F-E
FDUT56KXE6F-E
FDUT71KXE6F-E
2.2
2.5
2.8
3.2
3.6
4.0
1 Phase 220-240V, 50Hz
4.5
5.0
5.6
6.0
7.1
8.0
0.07-0.07
0.07-0.07
Hi:28 Me:26 Lo:22
Hi:32 Me:29 Lo:26
0.08-0.08
0.07-0.07
Hi:35 Me:31 Lo:28
Hi:41 Me:37 Lo:32
200x950x500
220x1150x565
25
31
Hi:16 Me:13 Lo:9.5
200x750x500
21
0.08-0.08
0.08-0.08
Hi:34 Me:32 Lo:28
Hi:35 Me:33 Lo:30
Hi:36 Me:33 Lo:27
Hi:38 Me:33 Lo:29
22
Hi:8.5 Me:7 Lo:5.5
Not possible
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static
pressure of indoor unit is 10Pa.
2. The data of nominal cooling and heating capacity and sound pressure level are measured with 10Pa of external static pressure.
3. The sound level indicates the value of rear-intake type with duct in anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
4. Sound pressure levels are values when 2m supply duct and 1m return duct are connected.
1 : Mike position is 1.5m below unit, 2 : Mike position is 1m in front and 1m below the air supply duct.
50
Dimensions
All measurements in mm.
FDUT45KXE6F-E, 56KXE6F-E
FDUT71KXE6F-E
51
R410A
RC-EX1A
Model No.
FDUH22KXE6F
FDUH28KXE6F
FDUH36KXE6F
RC-E5 RCH-E3
Wireless
UH-DU-E
RCN-KIT3-E
Quiet operation
570mm
257
mm
530m
Installation Flexibility
Control box and drain piping can be installed on both side of the unit and air intake
to the unit is available from bottom or back side. Our highest technology can satisfy
diverse installation requirements.
Control box
RCH-E3
(option)
Considering specialized
usage in hotel rooms,
control buttons are limited
only to minimum required
functions such as ON/OFF,
mode, temperature setting
and fan speed. It is really
simple and easy to use.
Drain piping
Specifications
Item
Model
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimensions HxWxD mm
Net weight
kg
Air flow
CMM
External static pressure Pa
Outside air intake
Air filter, Q'ty
Remote control(option)
Installation data
mm(in)
Refrigerant piping size
FDUH22KXE6F
2.2
2.5
FDUH28KXE6F
2.8
3.2
1 Phase 220-240V, 50Hz
0.05-0.07
0.05-0.07
HI: 33 Me: 30 Lo: 27
257x570x530
22
HI: 7 Me: 6.5 Lo: 6
30
Not possible
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
FDUH36KXE6F
3.6
4.0
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDUH22/28/36 39dB(A). Air flow: FDUH22/28/36 8.5CMM.
52
Dimensions
All measurements in mm.
32.5
83.3
32
27.6
Holes for
tapping screws
150
150
494
150
32
27.6
Symbol
A
B
C1,C2
D
E
F
(Duct dimension)
12-4
32.5
100
145
30.8
53
Content
Model
Gas piping
Liquid piping
Drain piping
Hole for wiring
Suspension bolts
Inspection hole
FDUH22KXE6F,28KXE6F
9.52 (3/8") (Flare)
6.35 (1/4") (Flare)
FDUH36KXE6F
12.7 (1/2") (Flare)
(Duct dimension)
575.2
255.8
30
32
27.5
610
66
37.6
188.5
148.5
Unit:mm
160
200
Air inlet
38.2
150
100
549.2
12-4
Holes for
tapping screws
890
600
21
68
150
494.2
574
150
32
27.5
30
28.3
Air
inlet
(D)
C2
530
488
62.1
Control box
Note(4)
156.8
A
B
30.8
40
21
273
66.4
66
95.3
C1
145.6
Air
outlet
30.8
Notes
( 1 ) The model name label is attached on the fan case
inside the air return grille.
( 2 ) Prepare the connecting socket (VP20) on site.
(As for drain piping, it is possible to choose C1 or C2)
( 3 ) When control box is located on the reverse side, Installation
space should be modified to new location.
( 4 ) Contorl box and Drain hose piece are able to be relocated
on the reverse side.
G
Bottom plate
(Able to be located on the back side)
View G
In case of Bottom air intake
150
150
30
12-4
Holes for
tapping screws
Air inlet
160
120
537.6
30
18.2
150
198.2
50.5
70
15
View G
(After bottom plate is replaced to back side)
53
R410A
Wall Mounted
FDK
Model No.
FDK22KXE6F
FDK28KXE6F
FDK36KXE6F
FDK45KXE6F
FDK56KXE6F
FDK71KXE6F
RC-EX1A
FDK22~56
RC-E5
RCH-E3
Wireless
RCN-K-E : FDK22~56
RCN-K71-E : FDK71
FDK71
Installation Workability
Innovative Design
259
Fast
Improved Maintainability
Slow
Upper
position
Movable
range
Lower
position
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure Cooling dB(A)
level
Heating
FDK22KXE6F
FDK28KXE6F
2.2
2.5
2.8
3.2
Installation data
Refrigerant piping size mm(in)
FDK45KXE6F
3.6
4.5
4.0
5.0
1 Phase 220-240V, 50Hz
0.05
0.04
Hi:35 Me:33 Lo:31
Hi:35 Me:33 Lo:31
FDK56KXE6F
FDK71KXE6F
5.6
6.3
7.1
8.0
0.09
0.09
Hi:47 Me:43 Lo:39
Hi:47 Me:43 Lo:39
0.05
0.05
Hi:41 Me:35 Lo:31
Hi:39 Me:35 Lo:31
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow
CMM
Outside air intake
Air filter, Qty
Remote control(option)
FDK36KXE6F
12
12.5
13
Hi:10 Me:9 Lo:7
Hi:11 Me:9 Lo:7
Hi:14 Me:12 Lo:10
Not possible
Polypropylene net x2 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-K-E (for FDK22~56), RCN-K71-E (for FDK71)
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
15.5
Hi:21 Me:18 Lo:15
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDK22/28 38dB(A), FDK36 48dB(A)(Cooling)&42dB(A)(Heating), FDK45 48dB(A)(Cooling)&43dB(A)(Heating), FDK56 48dB(A)(Cooling)&47dB(A)(Heating), FDK71 48dB(A).
Air flow: FDK22/28 11CMM, FDK36/45 15CMM, FDK56 16CMM, FDK71 24CMM.
54
Dimensions
All measurements in mm.
FDK71KXE6F
55
R410A
Ceiling Suspended
FDE
Model No.
FDE36KXE6F
FDE45KXE6F
FDE56KXE6F
FDE71KXE6F
FDE112KXE6F
FDE140KXE6F
RC-EX1A RC-E5
RCH-E3
Wireless
RCN-E-E
Small
Light-weight
Quiet
Sleek, intelligent design
New Slim Design
Selection of flap
position is possible.
A flap can be set at
different angles.
Upper
position
210mm
Movable
range
is not applicable to
*RCH-E3
the Flap control system.
Lower
position
Slim and sleek design starting at just 28kgs in weight means quick,
easy & neat installation.
Installation Workability
Up
Rear
Right
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
FDE36KXE6F
FDE45KXE6F
3.6
4.0
4.5
5.0
FDE56KXE6F
FDE71KXE6F
0.05-0.06
0.05-0.06
Hi:39 Me:38 Lo:36
5.6
7.1
6.3
8.0
1 Phase 220-240V, 50Hz
0.10-0.11
0.09-0.10
Hi:41 Me:39 Lo:37
Net weight
kg
Air flow
CMM
Outside air intake
Air filter, Qty
Remote control(option)
28
Hi:10 Me:9 Lo:7
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
37
Hi:16 Me:14 Lo:12
Not possible
Pocket Plastic net x2 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-E-E
FDE112KXE6F
FDE140KXE6F
11.2
12.5
14.0
16.0
0.14-0.16
0.13-0.15
Hi:44 Me:41 Lo:39
0.16-0.18
0.15-0.17
Hi:46 Me:44 Lo:43
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDE36/45/56 46dB(A), FDE71 50dB(A), FDE112 46dB(A), FDE140 50dB(A). Air flow: FDE36/45/56 11CMM, FDE71 18CMM, FDE112 28CMM, FDE140 32CMM.
56
Dimensions
All measurements in mm.
10
D
145
410
68
52
690
1070
195
60
15
20
C1,C2
235
Air supply
100
271
76
A C1
75
110
150 or more
19
Hole for
drain piping
(for left)
5 or more
Obstacle
135
175
300 or more
308
C2
Content
Gas piping
Liquid piping
Drain piping
Hole for suspension bolt
Back cutout
Top cutout
Hole for drain piping (for left back)
12
20
100 or more
Symbol
A
B
C 1,2
D
E
F
G
27
108
40
53
109
990
215
210
173
40
B
A
31
135
24
27
24
40
53
C1,C2
Make a space of 4000 or more between the units when installing more than one.
24
145
68
52
53
690
1320
195
60
15
20
C ,C
100
1 2
Drain hose piece (Accessory, 0.3m)
(Installed on site)
235
Air supply
Symbol
A
B
C 1,2
D
E
F
G
27
108
215
40
53
109
1240
210
173
271
175
A C1
110
Obstacle
135
145
52
40
108
53
109
250
255
5
1540
B
A
31
410
68
690
1620
195
235
Air supply
271
C ,C
15
20
60
100
1 2
Drain hose piece (Accessory, 0.3m)
(Installed on site)
76
A C1
110
135
300 or more
308
C2
75
Symbol
A
B
C1,2
D
E
F
G
Content
Gas piping
Liquid piping
Drain piping
Hole for suspension bolt
Back cutout
Top cutout
Hole for drain piping (for left back)
0
12
175
19
F
150 or more
20
100 or more
27
135
24
40
10
C1,C2
D
173
40
Hole for
drain piping
(for left)
Make a space of 4500 or more between the units when installing more than one.
FDE112KXE6F, 140KXE6F
24
19
5 or more
27
76
300 or more
308
C2
75
12
F
150 or more
20
100 or more
Content
Gas piping
Liquid piping
Drain piping
Hole for suspension bolt
Back cutout
Top cutout
Hole for drain piping(for left back)
53
40
B
A
410
31
135
40
24
27
FDE71KXE6F
10
C1,C2
5 or more
Obstacle
Make a space of 5000 or more between the units when installing more than one.
Hole for
drain piping
(for left)
G
E
57
R410A
Wired
RC-EX1A
RC-E5 RCH-E3
RCN-FW-E
Quiet Operation
Sophisticated Design
With classy semi flat front panel in chic white, the new
series fit in various kinds of rooms and create relaxing
atmosphere. Choice of wall hanging, floor standing or
behind gallery installation is available.
Flap control system
Selection of flap
position is possible.
A flap can be set at
different angles.
Upper
position
Movable
range
is not applicable to
*RCH-E3
the Flap control system.
Lower
position
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
FDFW28KXE6F
FDFW45KXE6F
FDFW56KXE6F
2.8
3.2
4.5
5.0
1 Phase 220-240V, 50Hz
0.02-0.02
0.02-0.02
Hi:38 Me:36 Lo:33
5.6
6.3
0.02-0.02
0.02-0.02
Hi:36 Me:34 Lo:30
Exterior dimensions
mm
HxWxD
0.03-0.03
0.03-0.03
Hi:44 Me:37 Lo:33
600x860x238
Net weight
kg
Air flow (Standard) CMM
Air filter, Qty
Remote control(option)
19
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
20
Hi:9 Me:8 Lo:7
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
58
Dimensions
All measurements in mm.
59
R410A
Wired
RC-EX1A
RC-E5 RCH-E3
RCN-KIT3-E
Model No.
FDFL71KXE6F
FDFU28KXE6F
FDFU45KXE6F
FDFU56KXE6F
FDFU71KXE6F
FDFL
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
FDFL71KXE6F
FDFU28KXE6F
7.1
8.0
2.8
3.2
0.09-0.10
0.09-0.10
Hi:43 Me:41 Lo:40
FDFU45KXE6F
FDFU56KXE6F
FDFU71KXE6F
5.6
6.3
7.1
8.0
4.5
5.0
1 Phase 220-240V, 50Hz
0.09-0.10
0.09-0.10
630x1481x225
630x1077x225
630x1362x225
Net weight
kg
Air flow (Standard) CMM
Air filter, Qty
Remote control(option)
40
Hi:18 Me:15 Lo:12
25
Hi:12 Me:11 Lo:10
32
Hi:18 Me:15 Lo:12
Installation data
Refrigerant piping size mm(in)
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
60
Dimensions
All measurements in mm.
FDFL
FDFU
Dimension Table
model
Unit:mm
786
810
722
750
806
FDFU71KXE6F
1071
1095
1007
1035
1091
61
R410A
Model No.
FDU500FKXE6F
FDU850FKXE6F
FDU1300FKXE6F
FDU1800FKXE6F
RC-EX1A
RC-E5 RCH-E3
Wireless
RCN-KIT3-E
Air conditioning and intake of outdoor air are in the same system
indoor unit
indoor unit
Outdoor Air
Processing unit
office
air
conditioning
outside
air supply
corridor
refresh room,
rest room
Compact design
exhaust air
outdoor air
supply air
outdoor air
supply air
(1) This unit is the specific unit for processing the outdoor air temperature closer to the room temperature. For conditioning the room temperature a
dedicated air-conditioner is required additionally.
(2) This unit monitors the outdoor air temperature and controls thermostat ON/OFF at the setting temperature by the remote controller, which
indicates the outdoor air temperature for controlling thermostat ON/OFF. When thermostat is turned OFF, the operation is changed to the fan mode
so that unprocessed outdoor air will be blown into the room directly. Therefore place the air outlet port or orient the air outlet direction not to blow
air directly to persons in the room, especially in the small room such as a restroom and/or sanitary hot water supplying room.
(3) It is strictly prohibited to monitor the room temperature by switching to the thermistor at remote controller side and/or the optional remote
thermistor. Otherwise dew formation at air outlet port and/or dew dripping may occur during cooling operation due to the lower outdoor air
temperature. Therefore keep the remote controller of this unit in place closer to the administrator so as not to be touched it freely by the end user.
(4) Dehumidifying operation with this unit is prohibited.
(5) When handing over this unit to the end user, make sure to explain sufficiently about the foregoing cautions, the installation place and usage of
remote control for this unit and the location of the air outlet.
62
Combination
The total capacity of FDU-F is 50~100% of outdoor capacity
A are connected with KX6 outdoor units and max quantity of FDU-F is 2 units.
In case both of OA processing units
[A]
10HP
[B]
FDU850FKXE6F FDU850FKXE6F
(5HP)
(5HP)
18HP
FDU850FKXE6F
(5HP)
6HP
6HP
Outside
Air Supply
Exhaust Air
Direct Expansion
Heat Exchanger
SAF
Outside
Air Supply
Exhaust Air
63
R410A
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimension
mm
HxWxD
FDU500FKXE6F
FDU850FKXE6F
FDU1300FKXE6F
FDU1800FKXE6F
9.0
4.2
14.0
7.0
22.4
10.9
28.0
14.8
0.11
0.11
38
0.16
0.16
41
0.27
0.27
43
0.31
0.31
46
360x820x830
360x1200x830
48
8.5
510
62
14
840
Net weight
kg
CMM
CMH
External static pressure Pa
Air filter, Q'ty
Remote control(option)
Air flow (Standard)
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
Installation data
mm
Refrigerating piping size (in)
360x1570x830
82
22
1320
84
30
1800
200
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:9.52(3/8")
Gas line:19.05(3/4")
Liquid line:9.52(3/8")
Gas line:22.22(7/8")
1. The data are measured at 33CDB 28CWB (68%RH) during cooling and 0CDB-2.9CWB (50%RH) during heating (no frost). External static pressure of indoor unit with optional fan controlling kit "U-FCRB" is 100Pa.
2. Temperature range of outdoor air must be 20~40CDB (32CWB) during cooling and -10~24CDB during heating.
3. Operation sound is measured in an anechoic room based on JIS standard. In case of actual room installation, it usually becomes higher than the displayed value due to the surrounding noise and echo.
4. The total connection capacity of the other standard air conditioning units and the outdoor air processing units must be from 50% to 100% (the total includes the outdoor air processing unit). The connection capacity
of the outdoor air processing unit must not exceed 30% of the capacity of the outdoor unit.
5. Single outdoor air processing unit can be used alone. The connection capacity of the outdoor air processing unit must be from 50% to 100% of the total capacity of the outdoor unit.
6. Single outdoor air processing unit can be used alone. Maximum number of outdoor air processing units that can be connected to the outdoor unit is 2units.
7. Values of sound pressure level become increased 5dB(A), when external static pressure is 200Pa (factory setting).
8. Values of air flow volume are those at external static pressure 200Pa (factory setting).
Dimensions
All measurements in mm.
FDU500FKXE6F
Control box
12-M5 screw
12-M5 screw
(Below suspension
bolt pitch)
Above
Below
or more
Plan view
or more
or more
Installation space
Installation space
Front view
or more
Installation space
Slab
64
or more
Piping space
(Service from below)
or more
Ceiling
Service space
Symbol
Content
Gas piping
Liquid piping
Drain piping connection
Power supply wiring connection
Suspension bolt
Inspection Opening
Inspection Opening
FDU850FKXE6F
Control box
or more
or more
Plan view
Below
Installation space
or more Installation space
or more
Installation space
Symbol
or more
Piping space
or more
Ceiling
FDU1300FKXE6F, FDU1800FKXE6F
Content
Gas piping
Liquid piping
Drain piping connection
Power supply wiring connection
Suspension bolt
Inspection Opening
Inspection Opening
Slab
Service space
12-M5 screw
Above
(Below suspension
bolt pitch)
16-M5 screw
Control box
20-M5 screw
Installation space
or more
Plan view
or more
Installation space
Below
or more
or more
Symbol
Slab
Service space
or more
Piping space
or more
Ceiling
Service space
Above
(Below suspension
bolt pitch)
20-M5 screw
Content
Gas piping
Liquid piping
Drain piping connection
Power supply wiring connection
Suspension bolt
Inspection Opening
Inspection Opening
65
R410A
Structure (SAF1000E4)
Plate heat exchanger
Exhaust Air
EA
(Exhaust Air)
RA
(Room Air)
outdoor
27deg
Capacity
outdoor
indoor
33deg
Supply Air
29deg
Outside Air
Room Air
35deg
27deg
Specifications
66
Exhaust Air
27deg
SA
(Supply Air)
SAF250E4
ENERGY RECOVERY
Supply Air
Room Air
10deg
Item
Model
Power source
Exterior dimensions
mm
Height x Width x Depth
Exterior appearance
Power input
W
Running current
A
Enthalpy
Cooling
exchange
UHi efficiency
Heating
Temperature exchange efficiency
Enthalpy
Cooling
exchange
Hi efficiency
Heating
%
Temperature exchange efficiency
Enthalpy
Cooling
exchange
Lo efficiency
Heating
Temperature exchange efficiency
Motor & Qty
kW
Air handling equipment Fan type & Qty
UHi
Air flow
Hi
m3/h
Lo
UHi
Available static pressure Hi
Pa
Lo
Remote control
Out take intake air
Air filter
Exhaust air
indoor
10deg
Outside Air
OA
(Outside Air)
FREE COOLING
Damper
SAF350E4
SAF500E4
SAF800E4
SAF1000E4
388x1322x884
388x1322x1135
309-359
1.48-1.50
360-399
1.85-1.93
270x882x804
99-114
0.46-0.48
63
70
124-137
0.59-0.60
66
69
63
70
66
69
66
73
77
0.02x2
69
71
77
0.044x2
250
250
170
90
80
37
350
350
280
95
65
42
270x962x904
Galvanised steel sheet
169-188
0.79-0.81
62
67
75
62
67
75
77
67
75
0.062x2
Sirocco fan x 2
500
500
370
105
70
38
Standard equipment
65
71
65
71
68
74
76
0.117x2
68
73
76
0.137x2
800
800
650
140
110
70
1000
1000
810
90
55
35
Dimensions
All measurements in mm.
SAF250E4,350E4,500E4
SAF800E4
SAF1000E4
Installation reference
Ceiling Suspension Bolt
Pipe Hood
Outside Intake Duct
SA
(Supply Air)
RA
OA
(Room Air)
EA
Dimension table
NO.
Name
Quantity
Material
Frame
Zinc-plated steel
SAF250E4
142
810
599
315
655
Adaptor
ABS Resin
SAF350E4
162
810
804
480
860
SAF500E4
202
890
904
500
960
Inspection Cover
Zinc-plated steel
Fan
ABS Resin
Motor
Filter
Damper
10
Damper Motor
11
Remarks
Model
Unit:mm
SAF250E4
219
164
144
882
95
SAF350E4
219
164
144
882
95
Collection Efficiency
Gravimetric Method 82%
SAF500E4
246
210
194
962
107
Non-woven Cloth
Model
Zinc-plated Steel
Note(1) An inspection port is needed for cleaning the heat exchanger and filter 1 or 2 times a year.
67
R410A
Remote control
(option)
Drain up kit
(option, built-in type)
(600mm)
Wired
DXA-DU-E
RC-E5
RCH-E3
Wireless
Model No.
SAF-DX250E6
SAF-DX350E6
SAF-DX500E6
SAF-DX800E6
SAF-DX1000E6
RCN-KIT3-E
SAF-DX is a heating or cooling coil incorporating MHI KX6 series controls. It can be used in combination with our SAF series of total heat exchanger.
Combination of SAF-DX together with other KX6 indoor units is possible. The capacity code index of each model is shown below and must be used when
making the system selection. Total capacity code index must be within 100% of outdoor unit capacity code index.
Remote control option is the same as with other KX6 indoor units (see above). Connection to all superlink controls is also possible.
Optional condensate lift mechanism is also available (600mm height).
Return air temp. control or supply air temp. control can be selectable.
RA
OA
(Outside Air)
(Room Air)
SAF-DX
Total heat
exchanger
EA
SA (Supply Air)
(Exhaust Air)
SAF-DX can provide heating or cooling to the fresh air supplied through a 3rd party air handling unit or total heat exchanger such as our SAF series.
Specifications
Model
Item
Nominal cooling capacity *1 kW
Nominal heating capacity *2 kW
Capacity code
Power source
Cooling
Power
consumption Heating W
Cooling
Running
A
current
Heating
SAF-DX250E6
SAF-DX350E6
SAF-DX500E6
SAF-DX800E6
SAF-DX1000E6
2.0
1.8
22
2.8
2.2
28
3.6
2.8
36
1 Phase 220-240V, 50Hz
7.2
7.2
0.05
0.05
5.6
4.5
56
6.3
5.6
71
13.6
500
16.1
800
18.4
1000
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow (Standard) CMH
Internal resistance Pa
Remote control(option)
350
66
wired: RC-E5, RCH-E3 wireless: RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Standards
ISO-T1
(2) This air-conditioner is manufactured and tested in conformity with ISO-T1 "UNITARY AIR-CONDITIONERS".
68
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
Dimensions
All measurements in mm.
SAF-DX250E6,350E6
SAF-DX500E6
SAF-DX800E6
SAF-DX1000E6
69
R410A
Control Systems
<Individual control>
Remote Control line up
indoor unit remote control
RC-EX1A
wired all models
RC-E5
RCH-E3
(except SAF)
indoor unit remote control indoor unit
FDT
RCN-T-36W-E
FDTS
wireless
FDTC
RCN-TC-24W-ER FDK22~56
FDTW
RCN-TW-E
FDK71
remote control
RCN-E-E
RCN-FW-E
RCN-KIT3-E
Timer operation
Changeable range
Upper limit
Lower limit
Thermistor (option)
SC-THB-E3
RCH-E3 (wired)
Considering specialized usage in hotel rooms, control buttons are limited only to
minimum required functions such as ON/OFF, mode, temperature setting and fan
speed. It is really simple and easy to use.
Up to 16 units
AUTO restart
*RCH-E3 is not applicable to the Individual flap control system and the Flap control system.
*When RCH-E3 is used, the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo).
RCN-T-36W-E,
RCN-TC-24W-ER
RCN-TW-E
RCN-TS-E
RCN-K-E,
RCN-K71-E
wireless remote control is not applicable to the Individual flap control system and the Flap control system.
*The
*When the wireless remote control is used, the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo).
70
RCN-E-E
RCN-FW-E
RCN-KIT3-E
<Control System>
SUPERLINKMHI has now combined simplicity of installation with our highly sophisticated
Superlink- control system, to offer building owners and occupiers a
comprehensive control and management system, while providing complete
commissioning and service maintenance assistance for installers and service
engineers. The Superlink- network utilises two wire, non-polar cable - for
further details of wiring.
SC-WGWNA-A/B
PC Control Interface
Center Control
SC-SL3NA-AE/BE
Wireless
remote
control
SC-ADNA-E
One-to-one
SC-ADNA-E
SC-ADNA-E
SC-ADNA-E
Wireless
71
R410A
<Central Control>
SC-SL1N-E
Start/stop control of up to 16 indoor units either
individually or collectively.
SL1N-E
More than one unit (up to 16) can be controlled for individual or collective
start/stop operation and indication of unit statuses such as in operation or in
need of service.
Outer dimensions: H120 x W120 x D15+62*mm.
62* is the measurement including the part contained in a recess.
SC-SL2NA-E
Central control of up to 64 indoor units including weekly timer function as standard.
SC-SL1N-E
Yes( 1)
Yes( 1)
Yes( 1)
Yes( 2)
Yes( 2)
Yes( 2)
network
2
5-8
3-4
0
4
Regarding previous Superlink, refer to Technical Manual '06 SC-T-111, '08 SC-T-119.
72
SC-SL2NA-E
Yes( 1)
Yes( 1)
Yes( 1)
Yes( 2)
Yes( 2)
Yes( 2)
SL1N-E
SC-SL3NA-AE/BE
Yes( 1)
Yes( 1)
Yes( 1)
Yes( 2)
Yes( 2)
Yes( 2)
SC-WGWNA-A/B
Yes( 2)
Yes( 2)
Yes( 2)
No
No
No
SC-BGWNA-A/B
Yes( 2)
Yes( 2)
Yes( 2)
No
No
No
SC-LGWNA-A
Yes( 2)
Yes( 2)
Yes( 2)
No
No
No
( 2) Number of units in combination of SC-WGWNA-A/B, SC-BGWNA-A/B, SC-LGWNA-A, SC-SL3NA-AE/BE, SC-SL2NA-E and SC-SL1N-E
Connectable number of controls in one superlink-
network
SC-SL1N-E
SC-SL2NA-E
SC-SL3NA-E-AE/BE
0-4
0-1
0-1
Regarding previous Superlink, refer to Technical Manual '06 SC-T-111, '08 SC-T-119.
SC-SL3NA-AE/BE
Monitoring
Scheduling
Administration/Service
Run/Stop
Operating state
Yearly schedule
Block definition
Mode (cool/heat/fan)
Mode
Today's schedule
Group definition
Set temperature
Set temperature
Unit definition
Operation permitted/prohibited
Room temperature
Fan speeds
Operation enabled
Alarm history
Air direction
Fan speed
Filter reset
Air direction
Filter sign
Maintenance (1, 2 or back-up)
Demand control
Breakdown
Emergency stop
Power failure recovery control
Printed board
ten's place
SW2
one's place
hundred's
place
Terminal block
Central Control
SW1
SW3
Electric wires
Inner wall
NEW
Applicable products
Ventilation fan, Air purifier
By using SC-GIFN-E together with central control such as SC-SL1N-E,
SC-SL2NA-E and SC-SL3NA-AE/BE, you can start-stop, operate & monitor
the operation of applicable products.
51X 52 52R
1 2 3 4 5 6 7 8 A B
40
more than
105mm
SLA3R-BX
Net work
Item
Model
Power supply
Power consumption
External dimensions
(Height x Width x Depth)
Net weight
Number of
connectable units (indoor units)
LCD touch panel
Inputs
SC-SL3NA-BE
Method of data saving
Calculation software
Air-conditioner power proportional distribution
pulse input
Connecting indoor units number (Maximum)
USB
Standard
8 systems
128
Outputs
SC-SL3NA-AE/SC-SL3NA-BE
0 ~ 40oC
1 Phase 100-240V 50/60Hz
18W
162mm x 240mm x 108mm
2.0kg
up to 128 units
Colour LCD, 7 inches wide
3 systems
8-point pulse width 100ms or more
1 point non-voltage a contact input
continuous input (closed, forced stop)
1 point non-voltage a contact input
continuous input (closed, demand control)
1 point maximum rated current 40mA, 24 V
During full stop; Open. If even one unit is operating; Closed
1 point maximum rated current 40mA, 24 V
Normal; closed. If even one unit is abnormal; Open
73
R410A
Production by order
Control and monitoring of up to 96 cells (some cells can have two or more indoor units and total number of
indoor units can be up to 128 units) centralised to a network PC using the Superlink- web gateway. Simple
installation is assured with no special software requirements, operation is via Internet Explorer. A low power
embedded CPU and compact flash ROM ensure a large storage capacity with high reliability (no moving parts
such as a PC fan, etc). An IP address filter function combined with three-level user authentication check also
ensures security.
SUPERLINK- No. 1 system
Internet
Explorer
64 units
48 cells
HUB
48 cells
Ethernet 10 BASE-T/
100BASE-TX
SC-ADNA-E
pulse
P1
P2
P3
P4
(in case of SC-WGWNB-B)
Cell
Production by order
(SC-BGWNA-A1 is with BLT Certification, SC-BGWNA-B is with electric power calculation function)
SC-BGWNA-A/B is an interface device that converts MHIs Superlink- communication data to BACnet code.
Control and monitoring functions of the a/c system for up to 96 cells (some cells can have two or more indoor
units and total number of indoor units can be up to 128 units) can be integrated to a central control point via
the building management system network.
SUPERLINK- No. 1 system
Ethernet 10 BASE-T/100BASE-TX
BACnet I/P Protocol.
48 cells
48 cells
Network
for
lighting
SC-ADNA-E
64 units
Emergency
sensor
network
Cell
pulse
P1
P2
P3
P4
(in case of SC-BGWNA-B)
Production by order
SC-LGWNA-A is an interface device that converts MHIs Superlink- communication data to LonWorks code.
Control and monitoring functions of the a/c system for up to 96 indoor units can be integrated to a central
control point via the building management system network.
SUPERLINK- No. 1 system
48 units
LonWorks network
(FTT-10)
74
Network
for
lighting
Emergency
sensor
network
SC-ADNA-E
48 units
Mechanical
chamber
Service maintenance and trouble shooting tasks can be carried out easily
via the wired remote controller, as well as a cooling test operation to
assist commissioning.
The outdoor unit control box is also equipped with a switch to invoke a
'test-run' mode. This function can be used to help detect any installation
errors, indoor/outdoor unit matching errors, EEV and valve operation. A
'pump-down' switch on the PCB allows refrigerant to be recovered with
the compressor protected.
All outdoor unit PCBs are also equipped with a 7-segment digital display
for detailed operation history and fault finding. Operation data is stored
for the 30 minute period preceding a fault occurring and details are
displayed on the 7-segment reading.
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
75
TOUCH SCREEN
MH-AC-KNX-128
Alams
INTEGRATED GATEWAY
Bidirectional: Supervision and Control
Robust and reliable hardware
Direct connection to KNX TP-1 BUS
Independent management of communications
Power supply: 230 VAC 50/60Hz
Wall mounting case
MH-AC-MBS-128
INTEGRATED GATEWAY
Bidirectional: Supervision and Control
Robust and reliable hardware
Modbus TCP or Modbus RTU RS-485/RS-232
Independent management of communications
Power supply: 230 VAC 50/60Hz
Wall mounting case
76
MODBUS
Example :
Device as Master
Example :
Device as Slave
TOUCH SCREEN
Windows
blinds
Alams
TOUCH SCREEN
Energy
management
Windows
blinds
Lighting
Alams
Energy
management
RC-E5
Lighting
HVAC
HVAC
Example :
Device as Master
MODBUS
Example :
Device as Slave
MODBUS
RC-E5
Example :
Device as Master
Example :
Device as Slave
RC-E5
Protocol : EnOcean
1i : 868MHz@EU
1iC : 315MHz@USA, ASIA
Dimension : 100 x 70 x 28 mm
External Power supply : no need
URL
email
tel
http://www.intesis.com
info@intesis.com
+34 938047 134
77
R410A
Outdoor units
Corrosion Protection Treatment series
4~48hp (11.2kW~136.0kW)
All KX6 outdoor series are available with special coating
applied for not only sheet metals but also small parts in
order to prevent salt corrosion caused by sea breeze in
area along coast line (Within approximately 500m from
coast line).
Model No.
FDCS112KXEN6
FDCS112KXES6
FDCS140KXEN6
FDCS140KXES6
FDCS155KXEN6
FDCS155KXES6
FDCS224KXE6G
FDCS280KXE6G
FDCS335KXE6G
Production by order
Sea breeze
Sea
Model No.
FDCS335KXE6-K
FDCS400KXE6
FDCS450KXE6
FDCS504KXE6
FDCS560KXE6
FDCS560KXE6-K
FDCS615KXE6
FDCS680KXE6
Combination systems:26~48hp (73.5kW~136.0kW) are the same as that of the standard KX6 series shown on previous pages.
Specifications and Dimensions are the same as that of the standard KX6 series shown on previous pages.
Non-CE Marking models.
For outside sheet metals, Cation electrodeposition coating is used for undercoat plus polyester powder coating or
acrylic backed coating for top coat and corrosion protection is applied for heat exchanger, welded parts, fan guard, fin
guard and other major parts.
Preventing corrosion by salt damage or sulfurous acid gas has made service life of KX6 series longer while its exterior
appearance has been greatly improved.
Durability of KX6 series for anticorrosion is about two times that of standard outdoor units under the same conditions.
78
12.20*.14~24HP
4~12HP
Exterior panel
Base plate
Drain pan
application of anticorrosion compound
Fan motor
4~6HP
8~12HP
Fin
pipe
Side plate
Compressor
Accumulator
Receiver
4~6HP
Heat exchanger
Control box
Baffle plate
8~12HP
4~6HP
8~12HP
4~6HP
8~12HP
Corrosion protection treatment complies with regulation of The Japan Refrigeration and Air Conditioning Industry Association (JRA9002)
Caution
Even if the outdoor unit is protected with the anti-salt damage treatment, it cannot be perfectly free from rusting.
The following points should be kept in mind during installation and maintenance of the outdoor units.
Installation
(1) When installing the outdoor unit close to the coastal area, provide a windbreak to protect it from direct sea breeze and
salt water splash.
(2) Select a well-drained place to install.
(3) If any scratch or damages occurred on the outdoor unit during installation, repair it carefully.
Maintenance
(1) Clean salt grains on the outdoor unit with fresh water periodically.
(2) Apply rust preventive at regular intervals for maintenance depending on the conditions at the installation place
(consulting with the withstanding capacity).
(3) Confirm reset of screw tap after maintenance, if missing it may cause corrosion occurred from the hole of screw tap.
(4) During prolonged non operation periods, protect the unit with covering.
79
R410A
Outdoor units
High Head series (100m) cooling only
14~48hp (40.0~136.0kW)
Model No.
FDCH335CKXE6G-K
FDCH400CKXE6G
FDCH450CKXE6G
FDCH504CKXE6G
FDCH560CKXE6G
FDCH560CKXE6G-K
FDCH615CKXE6G
FDCH680CKXE6G
Production by order
Model No.
FDCH735CKXE6G (FDCH335-K+FDCH400)
FDCH800CKXE6G (FDCH400x2)
FDCH850CKXE6G (FDCH400+FDCH450)
FDCH900CKXE6G (FDCH450x2)
FDCH960CKXE6G (FDCH450+FDCH504)
FDCH1010CKXE6G (FDCH504x2)
FDCH1065CKXE6G (FDCH504+FDCH560)
FDCH1130CKXE6G (FDCH560x2)
FDCH1180CKXE6G (FDCH560-K+FDCH615)
FDCH1235CKXE6G (FDCH615x2)
FDCH1300CKXE6G (FDCH615+FDCH680)
FDCH1360CKXE6G (FDCH680x2)
FDCH335CKXE6G-K & FDCH560CKXE6G-K are only used for combining with other models.
FDCH335CKXE6G-K
FDCH400CKXE6G
FDCH450CKXE6G
Total length:
1000m
To the
first branch:
max 130m
From the first
branch to the
furthest
indoor unit:
90m *1
FDCH504~680CKXE6G
Max: 10m
Outdoor
unit
Max: 5m
Indoor unit
Range of operation
50
+43C
Height
difference
50~100m
40
*2
30
Indoor unit
Indoor unit
Max height
difference
between
indoor units:
18m
20
Cooling
10
-5C
-10
*2 In case of less than 50m, the High Head models can not be applied.
In case Indoor unit is higher than outdoor unit, the High Head models can not be applied.
80
Specifications
Model FDCH400CKXE6G FDCH450CKXE6G FDCH504CKXE6G FDCH560CKXE6G FDCH615CKXE6G FDCH680CKXE6G
20HP
22HP
24HP
18HP
14HP
16HP
3 Phase 380-415V, 50Hz
kW
Cooling
56.0
61.5
68.0
50.4
40.0
45.0
A
Starting current
8
kW
Electrical characteristics Power consumption Cooling
16.79
20.37
24.98
14.73
11.27
12.97
Running current Cooling
A
27.4-25.1
33.1-30.3
40.3-36.9
24.1-22.0
18.4-16.9
21.1-19.3
HxWxD
Exterior dimensions
mm
1690x1350x720
2048x1350x720
Net weight
kg
357
319
343
R410A
Refrigerant charge
kg
11.5
Cooling
dB(A)
Sound pressure level
63.0
64.5
65.0
61.5
59.5
62.5
12.7(1/2")
Liquid line
15.88(5/8")
mm(in)
Refrigerant piping size
Gas line
28.58(1 1/8")
25.4(1") [28.58(1 1/8")]
28.58(1 1/8")
50~200
%
Capacity connection
50~160
Number of connectable indoor units
40
44
49
36
40
36
Item
Nominal horse power
Power source
Nominal capacity
Item
Model
Cooling
Starting current
Power consumption Cooling
Running current Cooling
HxWxD
R410A
Liquid line
Gas line
Capacity connection
Number of connectable indoor units
Item
kW
A
kW
A
mm
kg
kg
Electrical characteristics
Exterior dimensions
Net weight
Refrigerant charge
Refrigerant piping size
53
Cooling
Starting current
Power consumption Cooling
Running current Cooling
HxWxD
R410A
Liquid line
Gas line
kW
A
kW
A
mm
kg
kg
mm(in)
%
Model
96.0
27.70
45.2-41.3
319+343
Cooling
Starting current
Power consumption Cooling
Running current Cooling
HxWxD
R410A
Liquid line
Gas line
Capacity connection
Number of connectable indoor units
kW
A
kW
A
mm
kg
kg
FDCH800CKXE6G
FDCH1180CKXE6G
118.0
37.16
60.5-55.4
mm(in)
%
69
FDCH850CKXE6G
FDCH900CKXE6G
400CKXE6G
400CKXE6G
400CKXE6G
450CKXE6G
28HP
30HP
3 Phase 380-415V, 50Hz
80.0
85.0
16
22.54
24.24
36.8-33.8
39.5-36.2
1690x2700x720
319x2
11.5x2
19.05(3/4")
31.8(1 1/4") [34.92(1 3/8")]
50~160
58
61
FDCH1010CKXE6G
450CKXE6G
450CKXE6G
32HP
90.0
25.94
42.2-38.6
65
FDCH1065CKXE6G
FDCH1130CKXE6G
504CKXE6G
504CKXE6G
504CKXE6G
560CKXE6G
36HP
38HP
3 Phase 380-415V, 50Hz
101.0
106.5
16
29.46
31.52
48.2-44.0
51.5-47.1
2048x2700x720
343x2
11.5x2
19.05(3/4")
31.8(1 1/4")[34.92(1 3/8")]
50~160
69
59
560CKXE6G-K
615CKXE6G
42HP
Combination (FDCH)
Exterior dimensions
Net weight
Refrigerant charge
FDCH960CKXE6G
450CKXE6G
504CKXE6G
34HP
Item
Electrical characteristics
20.21
32.9-30.2
Model
Capacity connection
Number of connectable indoor units
73.5
mm(in)
Combination (FDCH)
Nominal horse power
Power source
Nominal capacity
FDCH735CKXE6G
335CKXE6G-K
400CKXE6G
26HP
Combination (FDCH)
FDCH1235CKXE6G
560CKXE6G
560CKXE6G
40HP
113.0
33.58
54.8-50.2
22.22(7/8")
38.1(1 1/2")
50~130
62
66
FDCH1300CKXE6G
FDCH1360CKXE6G
615CKXE6G
615CKXE6G
615CKXE6G
680CKXE6G
44HP
46HP
3 Phase 380-415V, 50Hz
123.5
130.0
16
40.74
45.35
66.2-60.6
73.4-67.2
2048x2700x720
357x2
11.5x2
22.22(7/8")
38.1(1 1/2")
50~130
72
76
680CKXE6G
680CKXE6G
48HP
136.0
49.96
80.6-73.8
80
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
81
R410A
Dimensions
All measurements in mm.
22
120
296.7
174
720
240
295
342
235
22
140
352 158
530
148
410
C (right)
Instruction plate
6
86.1
104.9
D (front)
95
Item
D (right)
90
86.5
220 180
550
180 214
Installation example
1
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
88
50
M10 x 4 places
45 x 3 places
20 x 6 places
3/8 flare
180 x 44.7
500
Open
10
200
100
300
10
Open
1500
Intake
L3
44.7
172
C (rear)
C (front)
20
K
B
A
166
169
211
259
291.6
84
L2
Wall
height H2
Wall
height H3
L4
Intake
Intake
Service
space
L1
A
B
C
D
F
G
H
K*
L
Air intake
F
For dimensions of anchor bolt hole
1690
797.8
Mark
Terminal block
for power cable
connection
80.5
71
57
85
80
D (left)
594
232
19
58.5
647
682
175
Signal wire
terminal block
232
D(lower)
185
7-segment display
inspection port
Drain pipe
74.5
1350
126.2
720
I F
250
175
172
234
75
142.5
19
141
95
140.5
726
K
B
F I
58.5
Dimensions of refrigerant
pipe connection (plan)
Rear
850
1000
85
101
250
175
Intake
Wall height H4
Wall height H1
Installation space
No restrictions No restrictions
1000
No restrictions
No restrictions
Installation example
Wall height
H3
Wall height
H2
L3
L2
L5
L6
L1 (Unit front side)
Wall height
H2
L4
Wall height
H4
Notes:
(1) The unit must be fixed with anchor bolts.
(2) Leave a 2m or larger space above the unit.
(3) The unit name plate is attached on the lower right corner of
the front panel.
(4) The ports for refrigerant pipe and power cable penetrations
are covered with half-blanks. Please cut off a half-blank with
nippers in using these ports.
(5) Use a 88 port for refrigerant pipe connection.
(6) Anchor holes marked L J (four holes for M10) are for a
renewal installation.
(7) The oil-equalising pipe K should be used when outdoor units
are used in combination. (For 14,16Hp only)
Dimensions
L1
500
Open
L2
10
200
L3
100
300
L4
10
Open
L5
400
L6
400
H1
1500
No restrictions
H2
H3
H4
82
No restrictions No restrictions
1000
No restrictions
No restrictions No restrictions
Dimensions
All measurements in mm.
234
75
142.5
19
120
22
80.5
71
296.7
85
Air intake
I
I F J
F
For dimensions of anchor bolt hole
J
174
720
240
295
57
594
232
352 158
530
148
410
342
235
22
I F
232
D(lower)
185
1350
2048
1155.8
126.2
720
F I
74.5
140
141
95
140.5
726
58.5
19
250
175
647
Rear
58.5
Dimensions of refrigerant
pipe connection (plan)
850
1000
85
101
250
175
A
B
C
D
F
G
H
K
L
Instruction plate
D (front)
104.9
6
86.1
95
Item
Service valve connection (gas side)
Service valve connection (liquid line)
Refrigerant pipe draw-out port
Power cable draw-in port
Anchor bolt hole
Drain hose hole
Drain discharge port
Oil-equalising pipe joint
Sling holes for haulage or hoisting
44.7
172
166
169
211
259
291.6
682
172
Terminal block
for power cable
connection
D (right)
90
86.5
220 180
550
180 214
Installation example
For refrigerant piping, please
refer to the unit specifications.
100
50
M10 x 4 places
45 x 3 places
20 x 6 places
9.52 flare
180 x 44.7
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
10
200
100
300
10
Open
1500
No restrictions No restrictions
1000
No restrictions
No restrictions
Intake
L2
L3
Mark
80
C (rear)
Wall
height H2
Service
space
Wall
height H3
L4
Intake
Intake
L1
D (left)
84
175
Signal wire
terminal block
C (right)
C (front)
20
K
B
A
7-segment display
inspection port
Drain pipe
Intake
Wall height H4
Wall height H1
Installation space
2m overhead clearance required
Notes:
(1) The unit must be fixed with anchor bolts.
(2) Leave a 2m or larger space above the unit.
(3) The unit name plate is attached on the lower right corner of
the front panel.
(4) The ports for refrigerant pipe and power cable penetrations
are covered with half-blanks. Please cut off a half-blank with
nippers in using these ports.
(5) Use a 88 port for refrigerant pipe connection.
(6) Anchor holes marked L J (four holes for M10) are for a
renewal installation.
(7) The oil-equalising pipe K should be used when outdoor units
are used in combination.
83
R410A
If replacing a used unit with a new one, Refresh KX can reuse existing piping.
Nominal Cooling Capacity
22.4kW
28.0kW
Model No.
FDCR224KXE6
FDCR280KXE6
NEW
<Option>
FDCR-V-KIT-E : Service valve kit
Applies to a wide range of pipe sizes (R22, R407C, R410A standard size).
Meets to a short period of renewal installation.
Savings on replacement expenses such as scrapping waste material or procuring new pipe.
Possible to replace the existing unit with a new larger capacity unit.
Possible to replace plural systems with one system.
For example:Existing 5HP x 2units can be replaced with a new 10HP x 1unit.
5HP x 2
10HP x 1
Outdoor unit
Range of operation
Indoor unit
Indoor unit
Indoor unit
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
50
+43C
40
Max height
difference
between
indoor units:
15m
30
20
Cooling
+15.5C
10
0
Heating
-10
-15C
Furthest
indoor unit: 160m
-20
-20C
Specifications
Item
Nominal horse power
Power source
Model
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Cooling/Heating
dB(A)
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDCR224KXE6
FDCR280KXE6
8HP
10HP
3 Phase 380-415V, 50Hz
22.4
25.0
28.0
31.5
5
5.60
6.03
9.25-8.47
9.85-9.02
8.09
8.21
13.22-12.10
13.41-12.28
1675x1080x480
224
11.5
58/58
59/60
9.52(3/8")~15.88(5/8")
19.05(3/4")~25.4(1")
22.22(7/8")~28.58(11/8")
50~130
13
16
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
84
1.Implement cooling operation of all indoor units for more than 30 minutes.
2.Implement pump-down after cooling operation.
3.Recover refrigerant and remove the existing outdoor unit and indoor unit.
7-segment display
Piping system
outdoor unit
indoor unit
heat exchanger
high
efficiency
strainer
compressor accumlator
Pipe refresh kit
high efficiency
strainer
oil separator
refrigerant flow
Dimensions
Service valve kit
Mark
A
B
C
D
E
F1
F2
F3
F4
G
Item
Service valve connection of the attached connecting pipe (gas side)
Service valve connection (liquid side)
Pipe/cable draw-out hole
Drain discharge hole
Anchor bolt hole
Cable draw-out hole
Cable draw-out hole
Cable draw-out hole
Cable draw-out hole
Connecting position of the local pipe. (gas side)
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts. An anchor bolt must not
protrude more than 15mm.
(3) Where the unit is subject to strong winds, lay it in such a direction that the
blower outlet faces perpendicularly to the dominant wind direction.
(4) Leave a 1m or larger space above the unit.
(5) A wall in front of the blower outlet must not exceed the units height.
(6) The model name label is attached on the lower right corner of the front.
(7) Connect the Service valve with local pipe by using the pipe of the
attachment.(Gas side only)
(8) Mark shows the connecting position of the local pipe.(Gas side only)
85
R410A
/further information
Mitsubishi Heavy Industries operates a continuous CSR (Corporate Social Responsibility) policy, with a role to realise a sustainable society through its
various areas of business.
Creed
We strongly believe that the customer comes first and that we are obliged to be an innovative partner to society.
We base our activities on honesty, harmony, and a clear distinction between public and private life.
We shall strive for innovative management and technological development from an international perspective.
Contribution to
Society through
Company Business
Environment,
Human Rights
and Labour
MHIs creed was established based on The Three Corporate Principles shared by the Mitsubishi Group
from the companys beginnings. In the spirit of this creed, MHI continues its efforts to fulfil its three
corporate social responsibilities (CSRs): corporate governance and compliance, the environment, human
rights and labour, and contribution to society through business activities.
Power &
Energy
MISSION
MISSION
Supply all areas of the
world with highly
efficient, clean energy
VISION
Environment
& Society
MISSION
Help people lead
fulfilled lives
86
Industries
MISSION
Support manufacturing
activities worldwide
The KX6 product range has been developed in compliance with the Mitsubishi Heavy Industries Policy on the Environment.
In order to make the sustainable development of society possible, a basic policy on environmental matters has been established.
Pursuant to the express provision of Section 1 of its creed that We strongly believe that customers come first and that we are obligated to be an
innovative partner to society, MHI shall, as a matter of primary importance, strive, through its R&D, manufacturing and other business activities, to play
a useful role in the development of society. To this end, while remaining aware that a business enterprise is a member of society, MHI shall endeavour,
in all aspects of its business activities, to reduce the burden on the environment and shall concentrate and fully utilise its technological capabilities for
the development of technologies and products that will protect the environment, thus contributing to the establishment of a society in which sustainable
development is possible.
In order to realise its basic policy, MHI has set the following seven conduct guidelines.
1. Recognise that environmental protection is top priority in the companys operations, and encourage the entire company in its endeavours to protect and
improve the environment.
2. Define roles and responsibilities regarding environmental protection by developing and maintaining a corporate organisation designated for environmental
protection, and create and implement corporate policies and procedures on environmental matters.
3. Endeavour to reduce the burden on the environment by preventing pollution, saving resources, saving energy, reducing waste, reusing materials, and recycling
in all aspects of the companys business activities in R&D, designing, procurement of materials, manufacturing, transportation, use, service and disposal.
4. Endeavour to develop and provide advanced, highly reliable, unique technologies and products that contribute to solving environmental and energy problems.
5. Comply with national and local environmental laws and regulations, beyond mere compliance by enacting, implementing and evaluating voluntary
standards where necessary, and to endeavour to continuously improve and promote environmental protection activities by establishing environmental
goals and targets.
6. Endeavour to protect the environments of foreign countries by carefully examining the consequences of the companys overseas business operations and
the exportation of its products, and to become actively involved in technological co-operation overseas in areas of environmental protection.
7. Provide environmental training and other programs to enhance the environmental awareness of all company employees, and take steps to expand public
relations activities, such as providing environment-related information to the public and social contribution activities.
as of March, 2011
Europe
Major subsidiaries
12
Japan
Head office & domestic offices
Research & development centres
Asia
Major subsidiaries
40
Works
Major domestic subsidiaries
23
9
6
14
109
Africa
Major subsidiary
Oceania
Major subsidiaries
87
global activity
On the land and sea, in the sky and even in space,
MHIs stage of operations is expanding limitlessly.
We manufacture more than 700 different products which
support various industrial and civil activities in both domestic
and international markets.
Ships, steel structures, power systems, machinery for
both industrial and general use, air-conditioners, pollution
reduction and environmental control systems, aerospace
systems the MHI product lines which create rich and
comfortable living environments, are as harmonious as
an orchestra.
RGY
S/ENE
URCE
RESO
EN
TIO
N
ME
ON
TA
VIR
OR
EN
SP
PM
LO
VE
AN
DE
TR
AL
88
C
LO
Chemical Plants
Wind Tunnel/Experiment
Equipment
Casting Machines
Strip Mill
Cement Plant
Stepless Variable Speed Gears
Industrial Robots
Injection Moulding Machines
Pulp & Paper Machinery
Corrugation Machines
Box Making Machines
Machine Tools
Cable Layer
Printing Machinery
INDUS
TRIAL
LEI
SU
RE
/LIF
IN
EST
FO
YLE
RM
AT
IO
N
SY
ST
EM
Oceanographic Research
Ships
Deep Submergence Research
Vehicles
Communications Satellite
Rockets
Space Transportation
Rockets & Engines
EL
V
DE
NT
E
PM
CE
N
EFE
Submarines
Naval Vessels
Jet Fighters
Helicopters
Missiles
Tanks & Infantry Fighting
Vehicles
89
Refrigerant leakage
The heating performance values (kW) described in catalog are the values
obtained by operating at an outdoor temperature of 7 C and indoor
temperature of 20 C as set forth in the ISO Standards. As the heating
performance decreases as the outdoor temperature drops, if the outdoor
temperature is too low and the heating performance is insufficient, use other
heating appliances as well.
The sound values are the values (A scale) measured in a chamber such as an
anechoic chamber following the ISO Standards. In the actual installation
state, the value is normally larger than the values given in the catalog due to
the effect of surrounding noise and echo. Take this into consideration when
installing.
Take the following measures when installing the outdoor unit in snowy areas.
Snow prevention
Install a snow-prevention hood so that the snow does not obstruct the air
intake port or enter and freeze in the outdoor unit.
Snow piling
Avoid installing this unit in as atmosphere where oil scatters or builds up,
such as in a kitchen or machine factory.
If the oil adheres to the heat exchanger, the heat exchanging performance
will drop, mist may be generated, and the synthetic resin parts may deform
and break.
In areas with heavy snow fall, the piled snow could block the air intake
port. In this case, a frame that is 50cm or higher than the estimated snow
fall must be installed underneath the outdoor unit.
Safety Precautions
Air-conditioner usage target
Installation
Before use
,
Always read the "User s Manual" thoroughly before starting use.
Usage place
Do not install in places where combustible gas could leak or where there
are sparks.
Installation in a place where combustible gas could be generated, flow or
accumulate, or places containing carbon fibers could lead to fires.
ISO 14001
Certificate 04104 1998 0813 E5
BIWAJIMA PLANT
HB91-13KX01E
Mitsubishi Heavy
Industries-Haier (Quingdao)
Air-conditioners Co.,Ltd.
BIWAJIMA PLANT
Mitsubishi Heavy
Industries-Haier (Quingdao)
Air-conditioners Co.,Ltd.
Because of our policy of continuous improvement, we reserve right to make changes in all specifications without notice.
Printed in Japan