On the older Symmetrix systems (4.0, 4.8, 5.0 and 5.5), the VCMDB (device) is mapped to all the channels,
host
In these systems the VCMDB access is typically restricted by Volume Logix or ACL (access control lists)
With the Symmetrix DMX, DMX2 Systems Enginuity Code 5670, 5671 the VCM device only requires to be
mapped to the Management stations
Management stations include SYMCLI Server / Ionix Control Center Server / Symmetrix Management Console
At all given times on the DMX, DMX2 platforms, the VCMDB would need to be mapped to at least one station
to perform online SDDR changes. Alternatively this problem of not having device mapped to at least one host
can also be fixed by the PSE lab
Mapping VCMDB to multiple hosts, channels may make the device venerable to crashes, potential tampering,
device attributes and data change
You can write disable VCMDB to avoid the potential of the above
With these systems, the host can communicate to the VCMDB via Syscalls
The VCM Edit Director Flag (fibrepath) needs to be enabled for management stations to see VCM device
The database (device masking database) of the VCMDB resides on the SFS volumes. This feature was
introduced with DMX-3 / DMX-4 (5772 version of microcode). A 6 cylinder VCM Gatekeeper device is okay to
use with these versions of microcode.
Starting Symmetrix V-Max systems, the concept of ACLX was introducted for Auto Provisioning etc.
Type 0: Symmetrix 4.0, 32 Director System, 16 cylinder device size, Volume Logix 2.x
Type 1: Symmetrix 4.8, 64 Director System, 16 cylinder device size, ESN Manager 1.x
Type 2: Symmetrix 5.0/5.5, 64 Director System, 16 cylinder device size, ESN Manager 2.x
Type 3: Symmetrix DMX, supports 32 fibre/ 32 iSCSI initiator records per port, 24 cylinder device in size.
Enginuity 5569, Solutions Enabler 5.2, Support 8000 devices
Type 4: Symmetrix DMX/DMX-2, supports 64 fibre/ 128 iSCSI initiator records per port, 48 cylinder device in
size. Enginuity 5670, Solutions Enabler 5.3, Supports 8000 devices
Type 5: Symmetrix DMX/DMX-2, supports 64 fibre / 128 iSCSI initiator records per port, 96 cylinder device
in size, Enginuity 5671, Solutions Enabler 6.0, Supports 16000 devices
Type 6: Symmetrix DMX-3, DMX-4, supports 256 fibre / 512 iSCSI initiator records per port, 96 cylinder
device in size, Enginuity 5771, 5772 Solutions Enabler 6.0, Supports 64000 devices
Type 3 of VCMDB can be converted to Type 4 VCMDB (code upgrade from 5669 to 5670 to 5671)
Solutions enabler 5.2 and Solutions Enabler 5.3 can read/write Type 3 VCMDB
VCMDB device is recommended to be a certain size, but it is okay to use a larger size device if no choices are
available.
If the device cylinder size is equal with a conversion you are attempting, the following will help you convert
your VCMDB from type x to type y.
Click on the Symmetrix array you are trying to initialize the VCMDB
.With SymCLI