You are on page 1of 8

UDSA & UDSBD model

Gas-fired unit heaters for indoor installation

Reznor V3 unit heaters are one of the most


technically advanced products available on the
market today. Incorporating a radical new heat
exchanger and burner. V3 is compact, lightweight and delivers the highest possible
standards of energy efficiency and
performance.
Within the V3 range there are two distinct
types of heaters;
UDSA - models fitted with an axial fan.
With a choice of 24 different units and a
range of heat output ratings from 8 to 100
kW, these models are available with both
horizontal and vertical down flow air discharge.
UDSBD - models fitted with centrifugal blower
in horizontal or vertical orientation. Sixteen
sizes of heaters with heat outputs ranging
from 15 to 64 kW.
Both UDSA and UDSBD heaters are easy to
install and they are suitable for a wide range
of commercial and industrial applications such
as retail premises, sports and leisure halls and
warehouses to mention but a few.

UDSA
TECHNICAL DATA
008

Model

011

015

020

Gas categories

025

030

035

II 2H3+UK
B22, C12, C32, C42, C52, C62, C82

Comb. air and venting; Type B & C Installations 1


Heat input (Hs)

kW

8,8

13,2

17,6

22,0

30,8

35,2

42,2

Heat input (Hi)

kW

7,9

11,9

15,9

19,8

27,8

31,7

38,0

Heat output

kW

7,3

11,0

14,6

18,2

25,5

29,2

34,9

Thermal efficiency (Hi)

92

92

92

92

92

92

92

natural gas G20


natural gas G25

m/h

0,84

1,26

1,68

2,10

2,94

3,36

4,02

m/h

0,98

1,46

1,95

2,44

3,42

3,90

4,68

propane G31

kg/h

0,62

0,93

1,24

1,55

2,16

2,47

2,96

Gas consumption rate

Rc 1/2

Gas connection size (not supply line size)


K

32

32

32

32

32

32

29

Airflow (15)

m/h

680

1020

1360

1700

2385

2725

3510

Motor speed
Vent & combustion air connection collars

rpm
mm

1425

1425

1425

1425

950

950

950

80

80

80

80

100

100

100

Recommended maximum hor. mounting height 2

m
m

2,5

2,5

3,0

3,0

3,5

3,5

3,5

10

13

16

20

22

25

dB(A)

47

46

47

48

50

51

55

Sound pressure level 5

dB(A)

40

39

40

41

43

44

48

Temperature rise

T (1)

Horizontal air throw 3


Sound pressure level

230/240V 1N ~ 50Hz

Electrical service (protection class IP 20)


Maximum total electrical rating

Weight (net)

kg

121
30

33

126
38

273
40

56

60

333
88

Energy saving

Easy installation and maintenance

4-way heat exchanger achieves over 92% ther-

Up to 25% lighter than similar models and

mal efficiency.

easy to install.

Reduced NOx emissions contribute to protect the

Balanced flue wall terminal provides both flue

environment.

outlet and combustion air inlet, thereby reducing

An improved airflow and a new louvre design

installation time.

give longer air throws and significantly

All connections (gas and electricity) are

reduce stratification within the

accessible at one side of the heater.

building. Consequently,
the units are particularly
suitable for well insulated

Extended operational life

buildings. If necessary, destratification fans can be installed.

The titanium stabilised aluminised steel heat

The aerodynamic heat exchanger profile enables

exchanger is particularly strong and durable

the UDSA model to increase the airflow up to

providing additional temperature resistance.

40% with a 30% reduction of electrical

Its weld free construction ensures long life.

consumption.
Patented self-aligning burner with
single orifice eliminates possible
flame impingement and premature
heat exchanger failure.
Maintenance is very
simple thanks to the use
of a single gas injector
for all models.

043

050

055

064

073

085

100

II 2H3+UK

Application versatility
Both horizontal and vertical downflow units are

B22, C12, C32, C42, C52, C62, C82


50,8

58,6

66,0

77,7

88,0

102,7

117,3

45,8

52,8

59,5

70,0

79,3

92,5

105,7

42,1

48,6

54,7

64,4

73,0

85,1

97,0

92

92

92

92

92

92

92

4,85

5,59

6,30

7,41

8,39

9,79

11,18

5,64

6,50

7,32

8,62

9,76

11,38

13,00

3,57

4,12

4,64

5,46

6,18

7,21

8,24

28

28

28

28

28

28

28

4535

5180

5830

6810

7770

9065

10360

950

950

950

950

950

950

950
130

available.
Fourteen different heat outputs from 8 to 100 kW.
The smallest unit is only 310mm high - making
it ideal for mounting in confined spaces.

Rc 3/4

100

100

130

130

130

130

3,5

3,5

3,5

4,0

4,0

4,0

4,0

28

30

30

33

35

36

39

54

55

56

56

58

59

59

47

48

49

49

51

52

52

490

490

490

678

848

848

848

99

99

112

118

143

158

168

230/240V 1N ~ 50Hz

Units may be suspended or base mounted on a


suitable support (fixed or pivoting).

UDSA
HORIZONTAL MODEL
MODEL UDSA DIMENSIONS (mm 2)
Size

008, 011

307

700

267

404

696

546

131

191

129

67

85

413

16

98

350

120

015

383

700

343

404

723

546

200

191

139

122

86

413

16

98

350

120

020

383

700

343

404

723

546

200

191

139

122

86

413

16

98

350

120

025

586

700

546

404

771

546

368

191

222

122

121

413

16

98

350

140

030

586

700

546

404

771

546

368

191

222

122

121

413

16

98

350

140

035, 043, 050

510

971

456

601

1129 897

371

195

126

166

121

623

33

149

600

140

055, 064

663

971

609

601

1138 897

354

207

150

166

204

623

33

149

600

225

073, 085, 100

865

1040 812

651

1138 897

562

213

299

186

204

673

33

149

600

225

2. Flue connection

3. Gas connection

4. Electrical connections

5. Service panel
Q

B
F

A
C

1. Combustion air inlet

5
3

SIDE VIEW

FRONT VIEW

TOP VIEW

K
H

REAR VIEW

REAR VIEW

(all models except for 035,


043, 050)

(models 035, 043, 050)

BALANCED FLUE WALL AND


ROOF TERMINAL

Type C12

Type C12b

Type C52

Type C32

Type B22

Type B22b

C- type: : the allowed length between the unit heater and the flue terminal amounts to 9m, a 90 bend offering an equivalent
resistance of 1.5m and a 45 bend -0.75m

UDSA
VERTICAL MODEL
To ensure that heat losses through the roof are
kept to a minimum and to avoid the occurrence
of stratification, it is possible to suspend the
UDSA unit in a vertical orientation. This way of
suspension allows the unit to dually operate as
a heater and as destratification unit.
The option vertical orientation (option number
205.8) can only be applied on the UDSA
models 015, 025, 035, 043, 050, 055, 064,
073, 085 & 100.
All vertical UDSA models are fitted with a 4way outlet grill (no louvres) and can be
functioning as a destratification unit by placing
a destratification thermostat (option 904) on the
unit. The unit now helps ventilating and
recirculating the warm air towards the floor,
resulting in energy savings and climate comfort.
Diffuser grill louvre setting

Floor pattern

Maximum mounting height from floor H (m) (1)


Air louvres
Air louvres
Air louvres
Model
Neutral
30
45
015
5,0
4,5
4,0
025
6,0
5,0
4,5
035
7,0
6,0
5,5
043
9,0
7,5
7,0
050
10,0
8,5
7,5
055
9,0
7,5
7,0
064
10,5
8,5
8,0
073
10,0
8,0
7,5
085
11,0
9,0
8,5
100
12,0
10,0
9,0
(1) max. mounting heights are defined at a uniform room temperature of 15C and a temperature rise at
nominal heat output

MOUNTING DATA

MODEL UDSA DIMENSIONS (mm 2)


Model

015

864

686

413

16

67

250

025

918

686

413

16

68

450

035, 043, 050 1270 1037

623

35

55

400

1278 1037

623

35

82

500

073, 085, 100 1317 1057

673

35

183

500

055, 064

for other dimensions: see table indicated as horizontal UDSA model

UDSBD
CENTRIFUGAL MODEL
These indirect gas-fired unit heaters have
separated combustion and an atmospheric
burner. The units are equipped with a direct
drive centrifugal blower and they can operate
effectively at a resistance output of up to 150
Pa. Furthermore, there is a choice of three
types of air distribution: plenum type, standard
outlet grill (fitted with vertical louvres) and
downturn nozzles. The unit is also available in
vertical downflow orientation in sizes 015, 025,

* outlet grill is optional

035, 043, 050, 055 and 064.


Designed for recirculation and air distribution
through ductwork UDSBD units are ideal for
open doorway heating (to prevent heat escaping) or for providing temperature controlled
space heating.

UDSBD
TECHNICAL DATA
015

Model

020

025

Gas categories

030

035

043

050

II 2H3+UK
B22, C12, C32, C42, C52, C62, C82

Comb. air and venting; Type B & C Installations 1


Heat input (Hs)

kW

Heat input (Hi)

kW

17,6
15,9

22,0
19,8

30,8
27,8

35,2
31,7

42,2
38

50,8
45,8

58,6
52,8

Heat output

kW

14,6

18,2

25,5

29,2

34,9

42,1

48,6

Thermal efficiency (Hi)

92

92

92

92

92

92

92

Gas consumption rate


natural gas G20
natural gas G25

m/h

1,68

2,10

2,94

3,36

4,02

4,85

5,59

m/h

1,95

2,44

3,42

3,90

4,68

5,64

6,50

propane G31

kg/h

1,24

1,55

2,16

2,47

2,96

3,57

4,12

Rc 3/4
31

Gas connection size (not supply line size)


Temperature rise

T (1) 6

Airflow (15)

K
m/h

2150

Motor speed

rpm

Standard low, mid or high speed


Recommended maximum hor. mounting height 2

20

Rc 1/2
23
27

25

25

2350

2750

3360

4080

3900

29

950

950

1430

1430

950

950

950

mid

high

low

mid

low

low

mid

4900

m
m

3,5

4,5

4,5

5,5

5,5

Horizontal air throw 3

18

23

26

26

32

34

38

Sound pressure level 4

dB(A)

50

52

47

51

46

47

52

Sound pressure level 5

dB(A)

57

58

54

58

53

54

59

230/240V 1N ~ 50Hz
1662
1662
1700

1700

1700

131

131

Electrical service (protection class IP 20)


Maximum total electrical rating

496

496

Weight (net)

kg

50

53

71

74

125

MODEL UDSBD DIMENSIONS (mm 2)


Size

015, 020

383

460

A1

700

343

404

935

546 199,5 191

025, 030

586

590

700

546

404

1185

546 367,5

035, 043, 050

510

670

970

456

601

1610

897

371

055

663

685

970

609

601

1610

897

354

064

663

720

970

609

601

1610

897

354

1. Combustion air inlet

2. Flue connection

3. Gas connection

139

122

86

413 15,5

98

350

120

191

222

194

126

122

121

413 15,5

98

350

140

165

121

623

33

148,5

600

140

206
206

150

165

204

623

33

148,5

600

225

150

165

204

623

33

148,5

600

225

4. Electrical connections

5. Service panel

FRONT VIEW

REAR VIEW
(models 015, 020,
025, 030, 055, 064)

055

064

66,0
59,5

77,7
70

54,7

64,4

92

92

6,30

7,41

7,32

8,62

4,64

5,46

30

32

5300

5390

950

950

mid

high

38

38

50

53

57

60

1700

1700

148

153

SIDE VIEW

TOP VIEW

REAR VIEW
(models 035, 043,050)

1) Gas appliance classifications for approved venting methods based on


CEN report - CR1749:2001.
2) Height from floor to bottom surface of the heater. These are RECOMMENDATIONS ONLY. Positioning of unit heaters for proper
performance is application dependent. Operation is affected by other
air moving equipment in the space, obstructions to the airflow,
draughts and/or close proximity doors or windows, etc. Care should
be taken to avoid mounting the heaters above these recommendations, unless downturn nozzle options are used, as significant
stratification may occur, resulting in poor floor coverage and higher
energy losses trough the roof structure.
3) Isothermal conditions , 20 C ambient air temperature , discharge
louvres , zero deflection , v=0,5m/s.
4) dB(A) values at 5 meters from the unit with reference circumstances
A=160m and Q=2.
5) dB(A) values at 5 meters from the unit in free field.
6) Values mesured with an external static pressure of 150 Pa.

OPTIONS
Unit heater accessories

Flue outlet

Two stage burner control

Balanced flue wall and roof terminal

Modulating burner control

- Aluminised steel plate

Propane model

- Adjustable chimney for pitched roof.

Destratification thermostat
Heat exchanger SS 409

Mounting

Diffuser grill with horizontal louvres

Both fixed or pivoting wall brackets are


available.

30 and 60 discharge nozzle


Vertical louvres
Duct flange *

Wall brackets for UDSA models 008-030

Constant running fan *

30 or 60 discharge nozzle

Control equipment
Wall brackets for UDSA models 035-100

Combined thermostat with


burner on indicator
and reset-function.
One or two stage clock
thermostat with burner
on indicator and reset.
Energymizor thermostat with time and temperature
control for one stage, two stage and modulating
REZNOR unit heaters. The microprocessor adjusts the
heating period and the air temperature.
Several thermostats can be

Pivoting wall bracket for UDSA models

connected together.

- Room temperature sensor for space heating.


- In-duct temperature sensor for warm air inlet system.*
Two stage duct thermostat. *
* UDSBD models only

Company Standards and Services:


All Reznor products are tested and approved to CE standards. Reznor Europe nv is assessed to GASTEC EN ISO 9001: 2000 Quality
Assurance. Reznor offers a service to its customers; including budget schemes, on site technical support and a comprehensive after-sales
package. Reznor reserves the right to change specifications without prior notice.

J&M Sabbestraat 130


B-8930 Menen
Reznor Europe N.V.
Belgium www.ReznorOnline.com
E-mail: reznor_europe@tnb.com
Tel. +32(0) 56 52 95 11
Fax. +32
(0) 56 52 95 33
Wijzigingen
voorbehouden
e-mail: reznor_europe@tnb.com
G A S T E C
website: www.reznor.be

A T&B Group Company

You might also like