You are on page 1of 2

Specialist Engineers in Noise Control and Vibration Control,

Architectural Louvre Systems and Plantroom Walls

Acoustic Doors type DAC 40 & DAC 33


Doors Type
Acoustic Doors
type DAC 40 &
& DAC
DAC 33
33
Usage

EMTEC DAC 40 and DAC 33 Acoustic Doors are double


Usagemetal doors specifically designed to provide
skinned
Usage
optimum
noise
combined
ease
operation.
EMTEC DAC
40 reduction
and DAC 33
Acousticwith
Doors
areofdouble
The
DACmetal
40 Acoustic
Door has a designed
nominal thickness
skinned
doors specifically
to provideof
100mm,
fittedreduction
with twincombined
peripheralwith
edgeease
seals,
gives an
optimumisnoise
of and
operation.
average
reduction
of 39dB
across the
audible frequency
The DACnoise
40 Acoustic
Door
has a nominal
thickness
of
spectrum.
DAC
33twin
Acoustic
Door has
nominal
100mm, is The
fitted
with
peripheral
edgea seals,
andthickness
gives an
of
50mm,
is fitted
with a of
single
seal,frequency
and gives
average
noise
reduction
39dBperipheral
across theedge
audible
an
average
noise
reduction
of
33dB.
spectrum. The DAC 33 Acoustic Door has a nominal thickness
of 50mm, is fitted with a single peripheral edge seal, and gives
an average noise reduction of 33dB.

Outside of EMTEC DAC33 Single Leaf Acoustic Door.


Outside
EMTEC40DAC33
Acoustic Door.
EMTECof DAC
and Single
DAC Leaf
33 Acoustic
Doors are supplied
complete with their own mounting frames and fixings for
fitting
prepared
structural
openings.
Single
and double
EMTECinto
DAC
40 and DAC
33 Acoustic
Doors
are supplied
leaf
doorswith
are available
with
the main
door and
leaf fixings
opening
complete
their own
mounting
frames
foreither
to
the right
or left as structural
required. openings. Single and double
fitting
into prepared
leaf doors
are available
with
the main
door
leafofopening
Typical
applications
of the
EMTEC
DAC
range
acousticeither
to the are
righttoor
left asaccess
required.
doors
permit
into such areas as Turbine or
Plantrooms,
Diesel
Test Cells,
TypicalEngine
applications
of theGenerator
EMTEC DAC
range of Ventilation
acoustic or
Air Conditioning
Plantrooms,
Chambers,
Industrial
doors
are to permit
access intoPlenum
such areas
as Turbine
or
ProcessEngine
Control
Rooms,
Havens,
Audiometric
Facilitiesor
Plantrooms,
Ventilation
Diesel
Test
Cells, Quiet
Generator
and
Recording
Studios.
Air Conditioning Plantrooms, Plenum Chambers, Industrial
Processany
Control
Rooms,
Quiet
Havens,
Audiometric
Facilities
Almost
size of
EMTEC
Acoustic
Door
can be manufactured
and
Recording
Studios.
to meet
customers
individual requirements and stable door
arrangements
small personnel
accesscan
doors
within larger
Almost any sizewith
of EMTEC
Acoustic Door
be manufactured
machine
entrance doors
can be
designed. Itand
is recommended
to meet customers
individual
requirements
stable door
that for your particular
consult
EMTEC
arrangements
with smallapplication
personnelyou
access
doorsanwithin
larger
engineer entrance
who will doors
be pleased
todesigned.
assist you Itinisthe
detailed
machine
can be
recommended
layout
an Emtec
DACapplication
door to meet
exactanphysical
that forofyour
particular
youyour
consult
EMTEC
requirements.
engineer who will be pleased to assist you in the detailed
layout of an Emtec DAC door to meet your exact physical
requirements.

Construction

The EMTEC DAC range of Acoustic Doors are manufactured

Construction
from
high quality galvanised steel sheets spot welded together
Construction

to form
a sandwich
construction
of Doors
considerable
strength.
The
EMTEC
DAC range
of Acoustic
are manufactured
Held high
between
thegalvanised
two skins of
thesheets
door isspot
an inert,
nonfrom
quality
steel
welded
together
flammable,
acousticconstruction
media whichof
effectively
absorbs
primary
to form a sandwich
considerable
strength.
and
secondary
acoustic
energy
incident
on
the
doors
inner
Held between the two skins of the door is an inert, nonsurface and acoustic
providesmedia
acoustic
damping
of theabsorbs
inner and
outer
flammable,
which
effectively
primary
skins
of the door.
The structural
integrityonofthe
thedoors
door and
and secondary
acoustic
energy incident
innerthe
mounting
is essential
todamping
ensure efficient
compression
of
surface andframe
provides
acoustic
of the inner
and outer
the
peripheral
edge
seals.
The mounting
provided
skins
of the door.
The
structural
integrity frames
of the door
and the
with
each door
of all welded
construction
furnished of
mounting
frameare
is essential
to ensure
efficientand
compression
complete
with edge
anchor
fixings
bolts to allow
forprovided
mounting
the peripheral
seals.
Theor
mounting
frames
into
structural
openings
(see details ofand
alternative
with existing
each door
are of all
welded construction
furnished
frames
onwith
the reverse
of this
data to
sheet).
complete
anchor side
fixings
or bolts
allow for mounting
into
openings
details of
alternative
Eachexisting
EMTEC structural
DAC Acoustic
Door (see
is furnished
with
heavy duty
frames on
the reverse
side of
this data
sheet).
hinges,
a positive
pressure
external
latch
and a quick release
mechanism
personnel
from the
enclosed
Each EMTECallowing
DAC Acoustic
Doortoisexit
furnished
with
heavy duty
beenlatch
locked
shut.
space
when the
door has
hinges,even
a positive
pressure
external
and
a quick release
mechanism
allowing can
personnel
to exitiffrom
the enclosed
Inspection windows
be provided
necessary
and EMTEC
has been
locked with
shut.a polyester
space
even when
theare
door
DAC Acoustic
Doors
normally
supplied
powder
coat
finish tocan
anybe
standard,
BS4800
or
Inspection
windows
providednon-metallic,
if necessary and
EMTEC
RAL colour.
DAC
Acoustic Doors are normally supplied with a polyester
powder coat finish to any standard, non-metallic, BS4800 or
RAL colour. Specification
Typical
The double and single leaf access doors into the Engine Test
Typical
Area
shallSpecification
beSpecification
EMTEC Type DAC Acoustic Doors having an
Typical
average
sound
of doors
39dB across
the
audible
The double
andreduction
single leafindex
access
into the
Engine
Test
frequency
spectrum.
shall be supplied
with an
a flush
Area shall be
EMTEC The
Typedoors
DAC Acoustic
Doors having
bottom cill
in order
to allow
access
into across
the testthe
area
by fork
average
sound
reduction
index
of 39dB
audible
lift trucks. spectrum.
An angle frame
with anchor
shallwith
be a flush
frequency
The doors
shall befixings
supplied
provided
toin
allow
fitting
into access
the prepared
bottom cill
order
to allow
into thestructural
test area by fork
openings.
doorsframe
and framework
be carefully
lift
trucks. The
An angle
with anchorshall
fixings
shall be located
into
the structure
that
complete
assembly is
provided
to allow ensuring
fitting into
thethe
prepared
structural
plumb
andThe
square
prior
final grouting
position.located
Each
openings.
doors
andtoframework
shallinto
be carefully
doorthe
leafstructure
shall be provided
an inspection
window and
into
ensuring with
that the
complete assembly
is
the complete
assembly
be polyester
powder
coatedEach
to
plumb
and square
priorshall
to final
grouting into
position.
colour
RAL
7019.
door leaf
shall
be provided with an inspection window and
the complete assembly shall be polyester powder coated to
colour RAL 7019.

EMTEC PAC40 Double and Single Leaf Acoustic Doors.


EMTEC PAC40 Double and Single Leaf Acoustic Doors.

NOISE CONTROL
Product Data Sheet No. 109/03
NOISE CONTROL
Product Data Sheet No. 109/03

Acoustic
Acoustic
Performance
Performance

Acoustic Door Type

DAC 40
DAC 33

Physical
Physical
Properties
Properties

Sound Reduction Index in dB


at Octave band centre frequencies (Hz)
63
23
20

125
25
22

250
34
29

500
39
34

1k
44
40

2k
48
38

4k
50
44

8k
49
38

EMTEC DAC 40 and DAC 33 Acoustic Doors can be furnished with many optional variations to suit the
individual requirements of particular installations. Besides the provision of inspection windows when
required and the choice of surface finish, the table below shows the full range of options available
when choosing your EMTEC DAC Acoustic Door.
The options required should be clearly stated at the time of enquiry but will be finally confirmed by
EMTEC Products Ltd. on a detailed design drawing issued for every door prior to manufacture.
Customer approval of this drawing is obtained prior to manufacture to ensure compatibility of the final
design requirements.
EMTEC DAC 40 Acoustic Doors weigh approximately 70kg/m2 and DAC 33 Acoustic Doors weigh
approximately 40kg/m2.
It is imperative that the framework of all EMTEC DAC Acoustic Doors be plumb and square prior to
final fixing as any inaccuracies in the positioning of the frame may compromise the final acoustic
performance that is achieved.

ANGLE FRAME

CHANNEL FRAME

BOX SECTION FRAME

BOLT FIXING

ANCHOR FIXING

ACOUSTIC PANEL FIXING

CHANNEL AND
CURTAIN SEALS

SCREWPLATE AND
CURTAIN SEALS

DOOR
FRAME
OPTIONS

FIXING
OPTIONS

BOTTOM
CILL
OPTIONS

DETAILS AS PER
DOOR FRAME OPTION

SINGLE LEAF
L.H. OPENING
R.H. OPENING

DOUBLE LEAF
L.H. OPENING
R.H. OPENING

DOOR
OPENING
OPTIONS

Emtec Products Ltd., Enterprise House,


Blyth Road, Hayes, Middlesex, UB3 1DD. Tel: 020 8848 3031. Fax: 020 8573 3605. Email: sales@emtecproducts.co.uk
Emtec Products Ltd,

T: 020 8848 3031


Data sheets are issued in all good faith and the information given is
Data sheets are issued in all good faith and
the information
given is current
the8573
time of3605
printing. However, EMTECcurrent
reservesatthe
to alter,
amend or
withdraw products
and whenthe
necessary.
Enterprise
House,
F: at
020
theright
time
of printing.
However,
EMTECas
reserves
right to
All rights to the products described in thisBlyth
data sheet
areHayes,
reserved to EMTEC.
Road,
E: sales@emtecproducts.co.uk
alter, amend or withdraw products as and when necessary. All rights
Middlesex, UB3 1DD

www.emtecproducts.co.uk

to the products described in this data sheet are reserved to EMTEC.