You are on page 1of 48

WCDMA RAN, Rel.

RU40,
Operating Documentation

Cable Lists for RNC2600


DN0938288
Issue 02D
Approval Date 2012-10-22

Cable Lists for RNC2600

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for
the use of Nokia Siemens Networks customers only for the purposes of the agreement under
which the document is submitted, and no part of it may be used, reproduced, modified or
transmitted in any form or means without the prior written permission of Nokia Siemens
Networks. The documentation has been prepared to be used by professional and properly
trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens
Networks welcomes customer comments as part of the process of continuous development
and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given as is and all
liability arising in connection with such hardware or software products shall be defined
conclusively and finally in a separate agreement between Nokia Siemens Networks and the
customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that
the instructions contained in the document are adequate and free of material errors and
omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks,
explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS
DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO
SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES,
SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS
INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE
USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2013. All rights reserved.

2 (48)

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

Contents

DN0938288
Issue 02D

1
1.1
1.2
1.3
1.3.1
1.3.2
1.4
1.5
1.6

Introduction .......................................................................................... 6
Numbering of the subrack shelves and cable connectors ....................... 6
Locking pegs .......................................................................................... 8
Categories of cables .............................................................................. 8
Interconnection cables ........................................................................... 8
Site cables ............................................................................................. 9
Identifying cables ................................................................................. 10
Cabling lists ......................................................................................... 12
Physical cable equipping positions and SW port connection
designation .......................................................................................... 13

2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8

Intra-cabinet cables for the RNAC cabinet ....................................... 16


RNAC power and fan tray control cables.............................................. 16
RNAC HMS and timing bus cables....................................................... 17
RNAC synchronization and LVDS cables ............................................. 23
RNAC LAN cables ............................................................................... 25
RNAC alarm and synchronization cables ............................................. 26
RNAC protection switch cables ............................................................ 29
RNAC PCIe and Mini SAS cables ........................................................ 30
L3 Data Collector Cables for RNAC cabinet ......................................... 31

3
3.1
3.2
3.3
3.4

Intra-cabinet cables for the RNBC cabinet ....................................... 32


RNBC power and fan tray control cables.............................................. 32
RNBC HMS bus and timing bus cables ................................................ 33
RNBC protection switch cables ............................................................ 36
L3 Data Collector Cables for RNBC cabinet ......................................... 38

4
4.1
4.2
4.3

Inter-cabinet cables from RNBC to RNAC ........................................ 40


Inter-cabinet HMS and timing cables.................................................... 40
Inter-cabinet SWU LAN cables ............................................................. 45
Inter-cabinet SFU LVDS lines .............................................................. 46

Nokia Siemens Networks

3 (48)

Cable Lists for RNC2600

Summary of changes
Changes between document issues are cumulative. Therefore, the latest
document issue contains all changes made to previous issues.
Note that our issue numbering system, safety information, and product
naming practice are changing. For more information, see Guide to
WCDMA RAN Operating Documentation.

Changes between issues 02C (2012-02-09, RU30) and 02D (2012-10-22, RU30)
Notes on timing bus cable daisy chain and star configurations are
added.
Inter-cabinet HMS and timing cables (4.1)
- A discussion on daisy chain cabling in RNC450 and RNC2600 is
added.
- A new table, Timing cables from RNBC to RNAC: daisy chain, is
added.

Changes between issues 02B (2011-06-09, RU30) and 02C (2012-02-09, RU30)
The description part in this document is updated.
Introduction (1)
-

Previous chapter 1 About Cable Lists for RNC450, chapter 2 Identifying


subracks, connectors and cables, and chapter 3 Physical cable equipping
positions and SW port connection coordinates are combined to current
chapter 1 Introduction.

Intra-cabinet cables for the RNAC cabinet (2.8)


-

Previous section of 6.1 L3 Data Collector Cables for RNAC cabinet is


combined to this chapter.

Intra-cabinet cables for the RNBC cabinet (3.4)


-

Previous section of 6.2 L3 Data Collector Cables for RNBC cabinet is


combined to this chapter.

Inter-cabinet HMS and timing cables (4.1)


-

4 (48)

In figure 9 Routing of HMS cables, it is corrected that the cable from RNAC
subrack 2 to RNBC subrack 1 is removed.

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

Changes between issues 02A (2011-03-01, RU30) and 02B (2011-06-09, RU30)
Inter-cabinet HMS and timing cables (5.1)

DN0938288
Issue 02D

The table of Inter-cabinet HMS and timing cables from RNAC to


RNBC is updated. The inter-cabinet timing cables are from RNAC to
RNBC with default and optional situations.

Figure 10 Routing of Inter-cabinet timing cables is added.

Nokia Siemens Networks

5 (48)

Cable Lists for RNC2600

Introduction
This document provides lists of the Inter-cabinet and Intra-cabinet cables
installed in RNAC and RNBC cabinets in RNC2600.
For more detailed information on RNC cabinet mechanics, see
Equipment Lists for RNC2600.
For basic information on, for example, RNC installation planning, see
IPA-RNC Engineering Description.
For detailed information on RNC hardware installation, see Installing the
MGW and IPA-RNC.
In RNC2600, the intra-cabinet timing bus cables, as well as the intercabinet HMS and timing cables, may follow either the daisy chain or
the star topology. The configuration must be uniform between RNAC
and RNBC. This cable list follows the star topology. For information on
the daisy chain topology, see Cable Lists for RNC450.

1.1

Numbering of the subrack shelves and cable


connectors
The equipment cabinets, subrack positions, and subrack cable
connectors are numbered in a way to aid installation.
The subrack positions of the cabinet are assigned with numbers from 1
to 4 from the top down. The subrack is identified by a sticker attached to
its upper left corner.
As you can see in below figure, each subrack has 20 slots. The slot
number is marked in front side of subrack. Slot 1 to 18 are full-height
plug-in units. Slot 19 and 38 are half-height plug-in units.

6 (48)

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

Slot position number

2
1

19 18 17 16 15 14 13 12 11 10 9

Subrack in position 1 seen from the rear

A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
Q
R

IPA2800 RNC / MGW cabinet,


seen from the front

S
T
U

F = FRONT
B = BACK

3 4

W
X
Y

1.0B 16.4X

DN05158647

CABLE FROM

Equip No.

F E DC B A Z

Connector
Type BDF

Connector
Type ACE

CABLE TO

FU

Connector

FU

Connector

Type

Use

CA_020

OMU 0

1.0B 16.4X

WDU 0-0

1.0B 17.3H

CJA002

SCSI bus 0

CA_021

OMU 0

1.0B 16.5D

WDU 0-0

1.0B 17.3O

CJB002

SCSI bus 0

Figure 1

DN0938288
Issue 02D

F E DC B A Z

Note

Notations used in the cabling lists

Nokia Siemens Networks

7 (48)

Cable Lists for RNC2600

1.2

Locking pegs
Each connector is provided with locking pegs or screws that fasten the
cable connector securely to the subrack.
The connector's locking pegs are placed in the same positions in each
subrack type, regardless of the subrack's position in a given cabinet. If
the subrack includes supplementary locking pegs, they can be used as
spare parts.

19 18 17 16 15 14 13 12 11 10 9

1
2

X
X

X
X
X
X

X
X
X
X

3
4
5

Figure 2

1.3

X
X
X
X

X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X

X
X

X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X

X
X

X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Locking pegs positions (DN0953997)

Categories of cables
The cabling of an network element consists of interconnection cables
(intermediate cables) and site cables (outgoing cables).

1.3.1

Interconnection cables
The interconnection cables comprise all the cables inside each cabinet
and between the cabinets which form a single network element. The
interconnection cables are equipped with connectors. They include:

8 (48)

Nokia Siemens Networks

DN0938288
Issue 02D

X
X
X
X
X
X
X
X
X
X

Cable Lists for RNC2600

power distribution cables

ATM connection cables

hardware Management Bus cables

synchronization and timing cables

SCSI cables between storage units and their master units

LAN/Ethernet cables

Intra-cabinet cables

The interconnection cables between different subracks located in the


same cabinet run from one subrack to another along the walls and
cabling shelves of the cabinet. These cables are delivered completely
installed in the cabinets.
Inter-cabinet cables

The interconnection cables running between different cabinets are led


directly from one cabinet to another on cable shelves located behind the
cabinets. These cables must be installed at the site. The interconnection
cables are delivered as prefabricated cable sets.

1.3.2

Site cables
The site (outgoing) cables are all the cables that leave the network
element. They include:

trunk circuit cables from the network interfaces

power supply cables

grounding cables

I/O cables

TCP/IP cables to the Network Management system

The site cables are connected directly to the plug-in units, or to the
connector panels located at the rear of the cabinets. These cables must
be installed at the site.
The site cables can be routed through the opening at the bottom (raised
floor installations) or top plate (normal installation) of the cabinet EC216.
These cables must be installed at the site.
All the cables entering the cabinet(s), except for the DC power feed
cables, must have protective wires which are grounded to the frame of
the network element at the connectors in the cabling cabinets.

DN0938288
Issue 02D

Nokia Siemens Networks

9 (48)

Cable Lists for RNC2600

The site cables are not delivered in sets and vary in length depending on
the delivery. They must be ordered separately and are designed for
each delivery.

1.4

Identifying cables
The equipping reference is located on the cable identification label (b in
Figure Example of marking system for the cables).
The first part of the equipping reference specifies the cable list where the
cable is mentioned. The second part gives the sequence number within
that list.
The equipping reference of the cables is based on the cabinet (type)
name in which the cable is connected. There are two main groups:
1. Cables whose both ends are connected in the same cabinet (Intracabinet cables).

The equipping information is expressed: [Cabinet type sequence


number].CA_123. There may be several identical cables of this type in
a single Network Element, but only one within the same cabinet.
2. Cables which originate from one cabinet and end in another (Intercabinet cables).

The equipping information is expressed: [Cabinet type, cabinet index_


sequence number].CBn_123. There may be only one of each
individual cable of this type in a single Network Element.
All Inter-cabinet cables connect from RNBC to RNAC.
The cabinet, where the cable starts in, determines the [cabinet type,
cabinet index] part of the equipping reference.

10 (48)

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

a)

a)
CA_020

CA_020

b)

a) Equipping number of cable, e.g.

CA-020

Sequential number

b) Cable identification label


Example

CJA002 ITEM NAME: C19179 .......... A01

LOT ID: 3G9912

Alias name
Fixed length (dm)
Item identifier
Separators
Interchangeability / version
Factory symbol
Year / Week
) A letter 'C' after the number indicates centimetres (cm) instead of decimetres (dm).

DN99632985

Figure 3

DN0938288
Issue 02D

Example of the marking system for the cables

Nokia Siemens Networks

11 (48)

Cable Lists for RNC2600

1.5

Cabling lists
The cables are listed in tables. Each cable has its individual number.
This number and the address of both ends of the cable are given. Both
the name of the functional unit and connector designation, to which the
end of the cable is connected, are given in a table. The columns of the
table are used as follows:
Table 1

Explanation of cabling list columns

FU

CABLE TO
Position

Cabinet

Equip.
No

Cabinet

CABLE FROM

FU

Position

Type

Use

Note

Equip.
No.

The equipping number is the individual number of the cable. Both ends of the cable bear a label with this number on it.

CABLE
FROM
(RNBC)

In case of Inter-cabinet cabling, the text CABLE FROM indicates that the cable originates from the RNBC cabinet.

CABLE
TO
(RNAC)

In case of Inter-cabinet cabling, the text CABLE TO indicates that the cable ends in the RNAC cabinet.

Cabinet

Cabinet A (RNAC) or cabinet B (RNBC).

FU

These columns give the name of the functional unit housed in the subrack where the ends of the cable connect to, for example
MXU.

Position

These columns give the designation of the connectors where the ends of the cable connect to.

Type

This column gives the type (the first three or four letters) and length (the following two or three numbers) of the cable in
decimeters, or if marked with a C, in centimetres. For example, CHA010 is a cable of CHA type which is 100 cm long.

Use

This column, when used, gives the type of signal carried by the cable, for example PDH line.

Note

This column is for additional information.

Tip
The lengths of Intra-cabinet cables in deliveries may be different than
those given in this document.

12 (48)

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

1.6

Physical cable equipping positions and SW port


connection designation
This section shows the physical cable equipping positions in the subrack
and the corresponding SW port connection designation, used in
hardware configuration management.
The cable connection designations are needed when creating internal
port connections between plug-in units' ports. For more information, see
Creating connection descriptions in Hardware Configuration
Management in IPA-RNC.
For example, for a cable installed in position 1.0B 1.4A, the port
connection coordinate in hardware configuration management (WF
commands) is B76. See also Figure 4 Notations used in table Physical
cable equipping positions and corresponding SW port connection
designation.

DN0938288
Issue 02D

Nokia Siemens Networks

13 (48)

Cable Lists for RNC2600

Slot position number


19 18 17 16 15 14 13 12 11 10 9 8

6 5

4 3 2

B1
B2
..
.
..
.
..
.

1
2

B25
B26

1
4

Subrack seen from the rear

B51

1 2

B76
SW
B1
B2

HW
1A
1B

SW
B26
B27

4A
HW
2A
2B

SW
B51
B52

HW
3A
3B

A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z

3
3
B76

4A

B101

SW
B76
B77

HW
4A
4B

SW HW
B101 5A
B102 5B

DN70206639

Figure 4

14 (48)

Notations used in table Physical cable equipping positions and


corresponding SW port connection designation

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

Table 2

Physical cable equipping positions and corresponding SW port


connection designation

SW

HW

SW

HW

SW

HW

SW

HW

SW

HW

B1

1A

B26

2A

B51

3A

B76

4A

B101

5A

B2

1B

B27

2B

B52

3B

B77

4B

B102

5B

B3

1C

B28

2C

B53

3C

B78

4C

B103

5C

B4

1D

B29

2D

B54

3D

B79

4D

B104

5D

B5

1E

B30

2E

B55

3E

B80

4E

B105

5E

B6

1F

B31

2F

B56

3F

B81

4F

B106

5F

B7

1G

B32

2G

B57

3G

B82

4G

B107

5G

B8

1H

B33

2H

B58

3H

B83

4H

B108

5H

B9

1J

B34

2J

B59

3J

B84

4J

B109

5J

B10

1K

B35

2K

B60

3K

B85

4K

B110

5K

B11

1L

B36

2L

B61

3L

B86

4L

B111

5L

B12

1M

B37

2M

B62

3M

B87

4M

B112

5M

B13

1N

B38

2N

B63

3N

B88

4N

B113

5N

B14

1O

B39

2O

B64

3O

B89

4O

B114

5O

B15

1P

B40

2P

B65

3P

B90

4P

B115

5P

B16

1Q

B41

2Q

B66

3Q

B91

4Q

B116

5Q

B17

1R

B42

2R

B67

3R

B92

4R

B117

5R

B18

1S

B43

2S

B68

3S

B93

4S

B118

5S

B19

1T

B44

2T

B69

3T

B94

4T

B119

5T

B20

1U

B45

2U

B70

3U

B95

4U

B120

5U

B21

1V

B46

2V

B71

3V

B96

4V

B121

5V

B22

1W

B47

2W

B72

3W

B97

4W

B122

5W

B23

1X

B48

2X

B73

3X

B98

4X

B123

5X

B24

1Y

B49

2Y

B74

3Y

B99

4Y

B124

5Y

B25

1Z

B50

2Z

B75

3Z

B100

4Z

B125

5Z

DN0938288
Issue 02D

Nokia Siemens Networks

15 (48)

Cable Lists for RNC2600

Intra-cabinet cables for the RNAC


cabinet
This chapter details the Intra-cabinet cabling for the RNAC cabinet in
RNC2600.
Single cabinet figures show the RNAC cabinet. Two-cabinet figures
show the RNAC and RNBC cabinets from left to right, unless otherwise
indicated.

Tip
The lengths of Intra-cabinet cables in deliveries may be different from
those given in this document.

2.1

RNAC power and fan tray control cables


Table 3

RNAC CPD120-A power and fan tray control cables

16 (48)

FU

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

Nokia Siemens Networks

FU

Position

Type

Use

Note

DN0938288
Issue 02D

Cable Lists for RNC2600

CABLE TO

CA_001
CA_002
CA_003
CA_004
CA_005
CA_006
CA_007
CA_008

A
A
A
A
A
A
A
A

CPD120 UB2
CPD120 UB1
CPD120 UB2
CPD120 UB1
CPD120 UB2
CPD120 UB1
CPD120 UB2
CPD120 UB1

0.10B P1
0.0B P1
0.10B P2
0.0B P2
0.10B P3
0.0B P3
0.10B P4
0.0B P4

A
A
A
A
A
A
A
A

PD30 0
PD30 0
PD30 1
PD30 1
PD30 2
PD30 2
PD30 3
PD30 3

1.0B 10_PP2
1.0B 10_PP1
2.0B 10_PP2
20B 10_PP1
3.0B 10_PP2
3.0B 10_PP1
4.0B 10_PP2
4.0B 10_PP1

CVXB004
CVXB004
CVXB015
CVXB015
CVXB020
CVXB020
CVXB027
CVXB027

Power
Power
Power
Power
Power
Power
Power
Power

CA_010
CA_011
CA_012
CA_013

A
A
A
A

FTRA 1
FTRA 2
FTRA 3
FTRA 4

1.0B
2.0B
3.0B
4.0B

A
A
A
A

PD30 0
PD30 1
PD30 2
PD30 3

1.0B 10_P1
2.0B 10_P1
3.0B 10_P1
4.0B 10_P1

CXVB18C
CXVB18C
CXVB18C
CXVB18C

Control
Control
Control
Control

FU

2.2

Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

FU

Type

Position

Use

Note

RNAC HMS and timing bus cables


The RNAC timing bus cable configuration shown on the table follows the
star topology. For information on the daisy chain topology, see Cable
Lists for RNC450.
Table 4

RNAC HMS and timing bus cables

DN0938288
Issue 02D

FU

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

Nokia Siemens Networks

FU

Position

Type

Use

Note

17 (48)

Cable Lists for RNC2600

CA_040
CA_041

A
A

CA_042
CA_043
CA_044

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

OMU 0
OMU 1

1.0B 16.3F
2.0B 16.3F

A
A

TBU 0
TBU 0

1.0B 19.2A
2.0B 19.2A

CHZ006
CHZ006

HMS bus 0
HMS bus 0

A
A
A

TBU 0
TBU 0
TBU 0

1.0B 19.2B
2.0B 19.2C
3.0B 19.2B

A
A
A

TBU 0
TBU 0
TBU 0

2.0B 19.2B
3.0B 19.2A
4.0B 19.2A

CHZ011
CHZ012
CHZ012

HMS bus 0
HMS bus 0
HMS bus 0

CA_046

TBU 0

4.0B 19.2C

TBU 0

4.0B 19.2D

CHZ001

HMS bus 0
term.

CA_047
CA_048

A
A

OMU 0
OMU 1

1.0B 16.3G
2.0B 16.3G

A
A

TBU 1
TBU 1

1.0B 38.5A
2.0B 38.5A

CHZ005
CHZ005

HMS bus 1
HMS bus 1

CA_049
CA_050
CA_051

A
A
A

TBU 1
TBU 1
TBU 1

1.0B 38.5B
2.0B 38.5C
3.0B 38.5B

A
A
A

TBU 1
TBU 1
TBU 1

2.0B 38.5B
3.0B 38.5A
4.0B 38.5A

CHZ009
CHZ010
CHZ010

HMS bus 1
HMS bus 1
HMS bus 1

CA_053

TBU 1

4.0B 38.5C

TBU 1

4.0B 38.5D

CHZ001

HMS bus1
term.

CA_054

TBU 0

1.0B 19.1Z

TBU 1

2.0B 38.4Z

CHZS010

HMS bus

CA_063
CA_064
CA_065

A
A
A

TBU 0
TBU 0
TBU 0

1.0B 19.2M
1.0B 19.2R
1.0B 19.2S

A
A
A

TBU 0
TBU 0
TBU 0

2.0B 19.2K
3.0B 19.2K
4.0B 19.2K

CHZ011
CHZ016
CHZ020

TIMING bus 0
TIMING bus 0
TIMING bus 0

CA_057

TBU 0

2.0B 19.2L

TBU 0

2.0B 19.2E

CHZ001

CA_058

TBU 0

3.0B 19.2L

TBU 0

3.0B 19.2E

CHZ001

CA_066

TBU 0

4.0B 19.2L

TBU 0

4.0B 19.2E

CHZ001

TIMING bus 0
term.
TIMING bus 0
term.
TIMING bus 0
term.

CA_070
CA_071
CA_072

A
A
A

TBU 1
TBU 1
TBU 1

2.0B 38.5R
2.0B 38.5S
2.0B 38.5M

A
A
A

TBU 1
TBU 1
TBU 1

1.0B 38.5K
3.0B 38.5K
4.0B 38.5K

CHZ009
CHZ010
CHZ015

TIMING bus 1
TIMING bus 1
TIMING bus 1

CA_074

TBU 0

1.0B 38.5L

TBU 0

1.0B 38.5E

CHZ001

CA_078

TBU 0

3.0B 38.5L

TBU 0

3.0B 38.5E

CHZ001

CA_073

TBU 1

4.0B 38.5L

TBU 1

4.0B 38.5E

CHZ001

TIMING bus 1
term.
TIMING bus 1
term.
TIMING bus 1
term.

18 (48)

FU

FU

Nokia Siemens Networks

Position

Type

Use

Note

DN0938288
Issue 02D

Cable Lists for RNC2600

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Terminating cables.
Be carefully:
Do not bend these
short cables.

38

DN05159607

Figure 5

DN0938288
Issue 02D

HMS bus cables

Nokia Siemens Networks

19 (48)

Cable Lists for RNC2600

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Timing bus 0
Timing bus 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Terminating cables.
Be carefully:
Do not bend these
short cables.

38

DN05159591

Figure 6

20 (48)

Routing of timing cables in RNAC

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

Table 5

RNAC default line timing cables

CA_060

CA_061

CABLE TO
Position

Cabinet

Equip.
No

Cabinet

CABLE FROM

NPS1/NPS1P 2

3.0B 16.4V

TBU 0

1.0B 19.2G

NPS1/NPS1P 3

4.0B 16.4V

TBU 0

CA_062

NPS1/NPS1P 4

3.0B 18.4V

CA_067

NPS1/NPS1P 2

3.0B 16.4X

CA_068

NPS1/NPS1P 3

CA_069

NPS1/NPS1P 4

FU

Use

Note

CHZ028

TIMING ref. 1

1.0B 19.2H

CHZ028

TIMING ref. 2

TBU 0

1.0B 19.2J

CHZ028

TIMING ref. 3

TBU 1

2.0B 38.5G

CHZ028

TIMING ref. 1

4.0B 16.4X

TBU 1

2.0B 38.5H

CHZ028

TIMING ref. 2

3.0B 18.4X

TBU 1

2.0B 38.5J

CHZ028

TIMING ref. 3

1) Default line
timing
1) Default line
timing
1) Default line
timing
1) Default line
timing
1) Default line
timing
1) Default line
timing

FU

Position

Type

1) These cables must be installed last. They are bundled separately from other cables for easier modification.

DN0938288
Issue 02D

Nokia Siemens Networks

21 (48)

Cable Lists for RNC2600

Figure 7

22 (48)

Routing of line timing cables

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

2.3

RNAC synchronization and LVDS cables


Table 6

RNAC SFU LVDS cables

CA_200

CA_201

CA_202

CA_203

CA_204

CA_205

CA_206

CA_207

CA_210

CA_211

CA_216

CA_217

CA_212

CA_213

CA_214

CA_215

CA_220

CA_221

CA_222

CA_223

CA_224

CA_225

CA_226

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

SFU 0 /
BISFD
SFU 0 /
BISFD
SFU 0 /
BISFD
SFU 0 /
BISFD
SFU 0 /
BISFD
SFU 0 /
BISFD
SFU 0 /
BISFD
SFU 0 /
BISFD

1.0B 1.B00

1.0B 1.B01

1.0B 1.B02

1.0B 1.B03

1.0B 1.B04

1.0B 1.B05

1.0B 1.B06

1.0B 1.B07

SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA

1.0B 2.B16

1.0B 2.B17

1.0B 2.B18

SFU 1 /
BISFD
SFU 1 /
BISFD
SFU 1 /
BISFD
SFU 1 /
BISFD
SFU 1 /
BISFD
SFU 1 /
BISFD
SFU 1 /
BISFD

FU

DN0938288
Issue 02D

FU
MXU 0 /
BISFB
MXU 1 /
BISFB
MXU 2 /
BISFB
MXU 3 /
BISFB
MXU 4 /
BISFB
MXU 5 /
BISFB
MXU 6 /
BISFB
MXU 7 /
BISFB

Position

Type

Use

Note

1.0B 9.B00

CSB007

LVDS lines

3)

1.0B 11.B00

CSB009

LVDS lines

3)

2.0B 9.B00

CSB012

LVDS lines

3)

2.0B 11.B00

CSB013

LVDS lines

3)

3.0B 9.B00

CSB017

LVDS lines

3)

3.0B 11.B00

CSB018

LVDS lines

3)

4.0B 9.B00

CSB022

LVDS lines

3)

4.0B 11.B00

CSB023

LVDS lines

3)

CSB009

LVDS lines

3)

CSB014

LVDS lines

3)

NPGE/NPGEP 0 / 1.0B 17.B00


NPS1/NPS1P 0
NPGE/NPGEP 1 / 2.0B 17.B00
NPS1/NPS1P 1
NPGE/NPGEP 2 1.0B 18.B00

CSB009

LVDS lines

1.0B 2.B19

NPGE/NPGEP 3

2.0B 18.B00

CSB014

LVDS lines

1.0B 2.B20

3.0B 15.B00

CSB019

LVDS lines

1.0B 2.B21

4.0B 15.B00

CSB025

LVDS lines

3)

1.0B 2.B22

3.0B 17.B00

CSB019

LVDS lines

3)

1.0B 2.B23

NPGE/NPGEP 4 /
NPS1/NPS1P 2
NPGE/NPGEP 5 /
NPS1/NPS1P 3
NPGE/NPGEP 6 /
NPS1/NPS1P 4
NPGE/NPGEP 7 /
NPS1/NPS1P 5

1) 3) Default:
connected
2) 3) Default:
connected
3)

4.0B 17.B00

CSB025

LVDS lines

3)

2.0B 1.B00

1.0B 9.B02

CSB012

LVDS lines

3)

2.0B 1.B01

1.0B 11.B02

CSB013

LVDS lines

3)

2.0B 1.B02

2.0B 9.B02

CSB007

LVDS lines

3)

2.0B 1.B03

2.0B 11.B02

CSB008

LVDS lines

3)

2.0B 1.B04

3.0B 9.B02

CSB012

LVDS lines

3)

2.0B 1.B05

3.0B 11.B02

CSB013

LVDS lines

3)

2.0B 1.B06

MXU 0 /
BISFB
MXU 1 /
BISFB
MXU 2 /
BISFB
MXU 3 /
BISFB
MXU 4 /
BISFB
MXU 5 /
BISFB
MXU 6 /
BISFB

4.0B 9.B02

CSB017

LVDS lines

3)

Nokia Siemens Networks

23 (48)

Cable Lists for RNC2600

CA_227

CA_230

CA_231

CA_236

CA_237

CA_232

CA_233

CA_234

CA_235

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

SFU 1 /
BISFD

2.0B 1.B07

MXU 7 /
BISFB

4.0B 11.B02

CSB018

LVDS lines

3)

SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA

2.0B 2.B16

CSB014

LVDS lines

3)

2.0B 2.B17

CSB008

LVDS lines

3)

2.0B 2.B18

NPGE/NPGEP 0 / 1.0B 17.B02


NPS1/NPS1P 0
NPGE/NPGEP 1 / 2.0B 17.B02
NPS1/NPS1P 1
NPGE/NPGEP 2 1.0B 18.B02

CSB015

LVDS lines

2.0B 2.B19

NPGE/NPGEP 3

2.0B 18.B02

CSB008

LVDS lines

1) 3) Default:
connected
2) 3) Default:
connected

SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA

2.0B 2.B20

3.0B 15.B02

CSB014

LVDS lines

3)

2.0B 2.B21

4.0B 15.B02

CSB019

LVDS lines

3)

2.0B 2.B22

3.0B 17.B02

CSB014

LVDS lines

3)

2.0B 2.B23

NPGE/NPGEP 4 /
NPS1/NPS1P 2
NPGE/NPGEP 5 /
NPS1/NPS1P 3
NPGE/NPGEP 6 /
NPS1/NPS1P 4
NPGE/NPGEP 7 /
NPS1/NPS1P 5

4.0B 17.B02

CSB019

LVDS lines

3)

FU

FU

Position

Type

Use

Note

1) Default: connected when NPGE/NPGEP 2 is in configuration.


Optional: removed when NPS1/NPS1P 0 is in configuration.
2) Default: connected when NPGE/NPGEP 3 is in configuration.
Optional: removed when NPS1/NPS1P 1 is in configuration.
3) Cables connected after panels BISFA, BISFB, BISFC and BISFD have been installed. Insert the back interface unit carefully, It is
important to check that the locking screws are closed properly, and that the back interface unit is well in its place

Table 7

TSS3 synchronization cable

CA_305

24 (48)

FU
TSS3

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

1.0B 19.1X

FU
TSS3

Nokia Siemens Networks

Position
2.0B 38.4X

Type

CHE011

Use

Note

Sync

DN0938288
Issue 02D

Cable Lists for RNC2600

2.4

RNAC LAN cables


Table 8

RNAC SWU (ESA40) LAN cables with one SWU pair (SWU
0/1)

CA_131
CA_130

A
A

SWU 0
SWU 0

1.0B 5.4E
1.0B 5.4C

A
A

OMU 1
OMU 0

2.0B 16.3B
1.0B 16.3B

CHES013
CHES006

LAN
LAN

CA_145

SWU 0

1.0B 5.5D

4.0B 17.4E

CIBS027

LAN

CA_144

SWU 0

1.0B 5.5B

3.0B 17.4E

CIBS021

LAN

CA_143

SWU 0

1.0B 5.4Z

4.0B 15.4E

CIBS027

LAN

CA_172

SWU 0

1.0B 5.4X

3.0B 15.4E

CIBS021

LAN

CA_147

SWU 0

1.0B 5.4V

NPGE/NPGEP 7 /
NPS1/NPS1P 5
NPGE/NPGEP 6 /
NPS1/NPS1P 4
NPGE/NPGEP 5 /
NPS1/NPS1P 3
NPGE/NPGEP 4 /
NPS1/NPS1P 2
NPGE/NPGEP 3

2.0B 18.4E

CIBS013

LAN

CA_146

SWU 0

1.0B 5.4T

NPGE/NPGEP 2

1.0B 18.4E

CIBS007

LAN

CA_171

SWU 0

1.0B 5.4R

CIBS013

LAN

CA_140

SWU 0

1.0B 5.4P

NPGE/NPGEP 1 / 2.0B 17.4E


NPS1/NPS1P 1
NPGE/NPGEP 0 / 1.0B 17.4E
NPS1/NPS1P 0

CIBS007

LAN

CA_134

SWU 1

2.0B 5.4J

SWU 0

1.0B 5.4J

CHES017

LAN

CA_139
CA_138

A
A

SWU 1
SWU 1

2.0B 5.4E
2.0B 5.4C

A
A

OMU 1
OMU 0

2.0B 16.3D
1.0B 16.3D

CHES007
CHES014

LAN
LAN

CA_155

SWU 1

2.0B 5.5D

4.0B 17.4G

CIBS021

LAN

CA_154

SWU 1

2.0B 5.5B

3.0B 17.4G

CIBS021

LAN

CA_153

SWU 1

2.0B 5.4Z

4.0B 15.4G

CIBS021

LAN

CA_152

SWU 1

2.0B 5.4X

3.0B 15.4G

CIBS014

LAN

CA_149

SWU 1

2.0B 5.4V

NPGE/NPGEP 7 /
NPS1/NPS1P 5
NPGE/NPGEP 6 /
NPS1/NPS1P 4
NPGE/NPGEP 5 /
NPS1/NPS1P 3
NPGE/NPGEP 4 /
NPS1/NPS1P 2
NPGE/NPGEP 3

2.0B 18.4G

CIBS007

LAN

CA_148

SWU 1

2.0B 5.4T

NPGE/NPGEP 2

1.0B 18.4G

CIBS013

LAN

CA_151

SWU 1

2.0B 5.4R

CIBS007

LAN

CA_150

SWU 1

2.0B 5.4P

NPGE/NPGEP 1 / 2.0B 17.4G


NPS1/NPS1P 1
NPGE/NPGEP 0 / 1.0B 17.4G
NPS1/NPS1P 0

CIBS013

LAN

FU

DN0938288
Issue 02D

Position

Cabinet

CABLE TO

Cabinet

CABLE FROM
Equip.
No

FU

Nokia Siemens Networks

Position

Type

Use

Note

2) Default:
connected
1) Default:
connected

3) Default:
Not
connected

2) Default:
connected
1) Default:
connected

25 (48)

Cable Lists for RNC2600

FU

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

FU

Position

Type

Use

Note

1) Default: Connected at factory. Connected when NPGE/NPGEP 2 is in configuration.


Optional: removed when NPS1/NPS1P 0 is in configuration.
2) Default: Connected at factory. Connected when NPGE/NPGEP 3 is in configuration.
Optional: removed when NPS1/NPS1P 1 is in configuration.
3) Default: Redundancy cable is not connected at the factory. Optional the cable is connected only when the Rabid Spanning Tree
Protocol (RSTP) is enabled in the LAN sub network. Before connecting the cable, remember to activate STP/RSTP/MSTP according to the
planned resiliency method

Table 9

Address setting modules

Position
1.0B 5.1S
1.0B 5.1U

ID
C108585
C108585

Name
ADMOD01
ADMOD01

Use
SWU
SWU

Note
Cabinet address setting module
Subrack address setting module

2.0B 5.1S
2.0B 5.1U

C108585
C108689

ADMOD01
ADMOD02

SWU
SWU

Cabinet address setting module


Subrack address setting module

2.5

RNAC alarm and synchronization cables


Table 10

RNAC alarm and synchronization cables to rear panels CPSYA, CPSY-B and CPAL-A

CA_015
CA_300
CA_301
CA_302
CA_303

A
A
A
A
A

CAIND
CPAL-A
CPAL-A
CPAL-A
CPSY-A

0.0B 1
2.0B 1.A
2.0B 1.G
2.0B 1.P
1.0B 1.C
1.0B 1.G
1.0B 1.L
1.0B 1.P

A
A
A
A
A

EHU
EHU
EHU
EHU
TSS3

3.0B 5.4E
3.0B 5.4G
3.0B 5.4P
3.0B 5.4X
1.0B 19.1V

CID030
CJA016
CHQ016
CHM016
CHE010

ALARM
Alarm
Alarm
Alarm
Sync

1)Default
2)Optional
3)Optional
4)Optional

CA_304

CPSY-B

1.10B 1.A
1.10B 1.E
1.10B 1.J
1.10B 1.N

TSS3

2.0B 38.4V

CHE010

Sync

1)Default
2)Optional
3)Optional
4)Optional

26 (48)

FU

Position

Cabinet

CABLE TO

Cabinet

CABLE FROM
Equip.
No

FU

Nokia Siemens Networks

Position

Type

Use

Note

DN0938288
Issue 02D

Cable Lists for RNC2600

CA_298
CA_299
CA_297

A
A
A

FU

CABLE TO
Position

SWU 0
CPSY-A
CPSY-A

1.0B 5.5Y
1.0B 1.1R
1.0B 1.1T

Cabinet

Cabinet

CABLE FROM
Equip.
No

A
A
A

FU

CPSY-A
CPSY-B
CPSY-B

Position

1.0B 1.1V
1.10B 1.1T
1.10B 1.1R

Type

CHE012
CHE005
CHE005

Use

Ethernet
Sync
Sync

Note

1) BNC IN, BNC OUT, Default


2) BNC IN, RJ 45 OUT, Optional
3) RJ 45 IN, BNC OUT, Optional
4) RJ 45 IN, RJ 45 OUT, Optional

DN0938288
Issue 02D

Nokia Siemens Networks

27 (48)

Cable Lists for RNC2600

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

CPSY-A

CPSY-B
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

CPAL-A
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

DN05160803

Figure 8

28 (48)

CPSY-A, CPSY-B and CPAL-A panel positions in RNAC

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

2.6

RNAC protection switch cables


Table 11

MSP1+1, PIU_OK, PAIR_OK and switchover cables for RNAC

CA_370

CA_375

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

NPS1P 0

1.0B 18.4T

NPS1P 1

2.0B 18.4T

CIBS010

NPS1P 0

1.0B 18.4R

NPS1P 1

2.0B 18.4R

CIBS010

CA_374

NPS1P 0

1.0B 18.4P

NPS1P 1

2.0B 18.4P

CIBS010

CA_165
CA_373

A
A

NPGEP 2
NPS1P 0

1.0B 18.4L
1.0B 18.4J

A
A

NPGEP 3
NPS1P 1

2.0B 18.4L
2.0B 18.4J

CHZS010
CIBS010

FU

NPGEP 2

FU

Position

Type

NPGEP 3

Use

MSP1+1
Protection
Switch
LVDS lines
Protection
Switch
LVDS lines
Protection
Switch
Switchover
MSP1+1
Protection
Switch
PIU_OK/
PAIR_OK
MSP1+1
Protection
Switch
MSP1+1
Protection
Switch
Switchover

Note

1) Default:
not connected
1) Default:
not connected
1) Default:
not connected

1) Default:
not connected

CA_372

NPS1P 0

1.0B 18.4G

NPS1P 1

2.0B 18.4G

CIBS010

CA_371

NPS1P 0

1.0B 18.4E

NPS1P 1

2.0B 18.4E

CIBS010

CA_163

1.0B 17.4L

CHZS010

1.0B 17.4K

NPGEP 1 /
NPS1P 1
NPGEP 1 /
NPS1P 1

2.0B 17.4L

CA_164

NPGEP 0 /
NPS1P 0
NPGEP 0 /
NPS1P 0

2.0B 17.4K

CHZS010

PIU_OK/
PAIR_OK

CA_358

NPS1P 2

3.0B 16.4T

NPS1P 3

4.0B 16.4T

CIBS010

CA_361

NPS1P 2

3.0B 16.4R

NPS1P 3

4.0B 16.4R

CIBS010

CA_360

NPS1P 2

3.0B 16.4P

NPS1P 3

4.0B 16.4P

CIBS010

CA_351

NPS1P 2

3.0B 16.4J

NPS1P 3

4.0B 16.4J

CIBS010

CA_359

NPS1P 2

3.0B 16.4G

NPS1P 3

4.0B 16.4G

CIBS010

CA_350

NPS1P 2

3.0B 16.4E

NPS1P 3

4.0B 16.4E

CIBS010

CA_161

3.0B 15.4L

CHZS010

3.0B 15.4K

NPGEP 5 /
NPS1P 3
NPGEP 5 /
NPS1P 3

4.0B 15.4L

CA_162

NPGEP 4 /
NPS1P 2
NPGEP 4 /
NPS1P 2

MSP1+1
Protection
Switch
LVDS lines
Protection
Switch
LVDS lines
Protection
Switch
MSP1+1
Protection
Switch
MSP1+1
Protection
Switch
MSP1+1
Protection
Switch
Switchover

4.0B 15.4K

CHZS010

PIU_OK/
PAIR_OK

DN0938288
Issue 02D

Nokia Siemens Networks

1) Default:
not connected

29 (48)

Cable Lists for RNC2600

CA_354

CA_357

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

NPS1P 4

3.0B 18.4T

NPS1P 5

4.0B 18.4T

CIBS010

NPS1P 4

3.0B 18.4R

NPS1P 5

4.0B 18.4R

CIBS010

CA_356

NPS1P 4

3.0B 18.4P

NPS1P 5

4.0B 18.4P

CIBS010

CA_353

NPS1P 4

3.0B 18.4J

NPS1P 5

4.0B 18.4J

CIBS010

CA_355

NPS1P 4

3.0B 18.4G

NPS1P 5

4.0B 18.4G

CIBS010

CA_352

NPS1P 4

3.0B 18.4E

NPS1P 5

4.0B 18.4E

CIBS010

CA_156

3.0B 17.4L

CHZS010

3.0B 17.4K

NPGEP 7 /
NPS1P 5
NPGEP 7 /
NPS1P 5

4.0B 17.4L

CA_157

NPGEP 6 /
NPS1P 4
NPGEP 6 /
NPS1P 4

4.0B 17.4K

CHZS010

FU

FU

Type

Position

Use

Note

MSP1+1
Protection
Switch
LVDS lines
Protection
Switch
LVDS lines
Protection
Switch
MSP1+1
Protection
Switch
MSP1+1
Protection
Switch
MSP1+1
Protection
Switch
Switchover

PIU_OK/
PAIR_OK

1) Default: Not connected at the factory. Cable is tied to the SRBI-C side plate near these equipping positions. Optional: Cables are
connected these equipping positions when NPS1P 0 and NPS1P 1 pair are equipped.

2.7

RNAC PCIe and Mini SAS cables


Table 12

RNAC PCIe and Mini SAS cables

30 (48)

FU

Position

CABLE TO
Cabinet

Cabinet

CABLE FROM
Equip.
No

Nokia Siemens Networks

FU

Position

Type

Use

Note

DN0938288
Issue 02D

Cable Lists for RNC2600

CA_075
CA_076
CA_077

A
A
A

FU
OMU 0
OMU 1
WDU 0 (OMU)

2.8

CABLE TO

Position
1.0F 16.PCIe1
2.0F 16.PCIe1
1.0F 14.SAS

Cabinet

Cabinet

CABLE FROM
Equip.
No

A
A
A

FU
WDU 0 (OMU)
WDU 1 (OMU)
WDU 1 (OMU)

1.0F 14.PCIe
2.0F 14.PCIe
2.0F 14.SAS

Type

CQSFP25C
CQSFP25C

CMSAS011

Use

Note

PCIe
PCIe
SAS

L3 Data Collector Cables for RNAC cabinet


Table 13

L3 Data Collector Cables for RNAC cabinet

CABLE FROM

CA_250

CA_251

CA_252
CA_253

CABLE TO
Position

Cabinet

No

Cabinet

Equip.

Position

ICSU 0

1.0B 03.3B

CPLAN-A

Port 4

CHUS014

LAN EL0

RSMU 0

1.0B 04.3B

CPLAN-A

Port 2

CHUS014

LAN EL0

OMU 0

1.0B 16.3B

CPLAN-A

Port 0

CHUS016

LAN EL1

ICSU 1

2.0B 03.3B

CPLAN-A

Port 5

CHUS021

LAN EL0

CA_254

RSMU 1

2.0B 04.3B

CPLAN-A

Port 3

CHUS021

LAN EL0

CA_255

ICSU 2

2.0B 06.3B

CPLAN-A

Port 6

CHUS021

LAN EL0

CA_256

OMU 1

2.0B 16.3B

CPLAN-A

Port 1

CHUS020

LAN EL1

CA_257

ICSU 3

3.0B 01.3B

CPLAN-A

Port 7

CHUS024

LAN EL0

CA_258

ICSU 4

3.0B 02.3B

CPLAN-A

Port 8

CHUS024

LAN EL0

CA_259

ICSU 5

3.0B 03.3B

CPLAN-A

Port 9

CHUS024

LAN EL0

CA_260

ICSU 6

3.0B 04.3B

CPLAN-A

Port 10

CHUS024

LAN EL0

CA_261

ICSU 7

3.0B 14.3B

CPLAN-A

Port 11

CHUS025

LAN EL0

CA_262

ICSU 8

4.0B 01.3B

CPLAN-A

Port 12

CHUS025

LAN EL0

CA_263

ICSU 9

4.0B 02.3B

CPLAN-A

Port 13

CHUS026

LAN EL0

CA_264

ICSU 10

4.0B 03.3B

CPLAN-A

Port 14

CHUS026

LAN EL0

CA_265

ICSU 11

4.0B 04.3B

CPLAN-A

Port 15

CHUS026

LAN EL0

CA_266

ICSU 12

4.0B 05.3B

CPLAN-A

Port 16

CHUS026

LAN EL0

CA_267

ICSU 13

4.0B 14.3B

CPLAN-A

Port 17

CHUS027

LAN EL0

DN0938288
Issue 02D

FU

FU

Nokia Siemens Networks

Position

Type

Use

Note

Optional

Optional

31 (48)

Cable Lists for RNC2600

Intra-cabinet cables for the RNBC


cabinet
This chapter presents the Intra-cabinet cabling for the RNBC cabinet in
RNC2600.

Tip
The lengths of Intra-cabinet cables in deliveries may be different than
those given in this document.

3.1

RNBC power and fan tray control cables


Table 14

RNBC CPD120-A power cables and fan tray control cables

No

Cabinet

CABLE TO

CB_001

CPD120 UB2

0.10B P1

PD30 0

1.0B 10_PP2

CVXB004

Power

CB_002

CPD120 UB1

0.0B P1

PD30 0

1.0B 10_PP1

CVXB004

Power

CB_003

CPD120 UB2

0.10B P2

PD30 1

2.0B 10_PP2

CVXB015

Power

CB_004

CPD120 UB1

0.0B P2

PD30 1

2.0B 10_PP1

CVXB015

Power

CB_005

CPD120 UB2

0.10B P3

PD30 2

3.0B 10_PP2

CVXB020

Power

CB_006

CPD120 UB1

0.0B P3

PD30 2

3.0B 10_PP1

CVXB020

Power

CB_007

CPD120 UB2

0.10B P4

PD30 3

4.0B 10_PP2

CVXB027

Power

CB_008

CPD120 UB1

0.0B P4

PD30 3

4.0B 10_PP1

CVXB027

Power

CB_010

FTRA 1

1.0B

PD30 0

1.0B 10_P1

CXVB18C

Control

CB_011

FTRA 2

2.0B

PD30 1

2.0B 10_P1

CXVB18C

Control

32 (48)

FU

Position

Cabinet

CABLE FROM
Equip.

FU

Nokia Siemens Networks

Position

Type

Use

Note

DN0938288
Issue 02D

Cable Lists for RNC2600

No

Cabinet

CABLE TO

CB_012

FTRA 3

3.0B

PD30 2

3.0B 10_P1

CXVB18C

Control

CB_013

FTRA 4

4.0B

PD30 3

4.0B 10_P1

CXVB18C

Control

FU

3.2

Position

Cabinet

CABLE FROM
Equip.

FU

Type

Position

Use

Note

RNBC HMS bus and timing bus cables


The RNBC timing bus cable configuration shown on the table follows the
star topology. For information on the daisy chain topology, see Cable
Lists for RNC450
Table 15

RNBC HMS and timing bus cables

CABLE FROM

CB_020

CB_021

CABLE TO
Position

Cabinet

No

Cabinet

Equip.

TBU 0

1.0B 19.2B

TBU 0

2.0B 19.2A

CHZ011

HMS bus 0

TBU 0

2.0B 19.2B

TBU 0

3.0B 19.2A

CHZ011

HMS bus 0

CB_022

TBU 0

3.0B 19.2B

TBU 0

4.0B 19.2A

CHZ011

HMS bus 0

CB_023

TBU 0

4.0B 19.2C

TBU 0

4.0B 19.2D

CHZ001

HMS bus 0
term

CB_024

TBU 1

1.0B 38.5B

TBU 1

2.0B 38.5A

CHZ009

HMS bus 1

CB_025

TBU 1

2.0B 38.5B

TBU 1

3.0B 38.5A

CHZ009

HMS bus 1

CB_026

TBU 1

3.0B 38.5B

TBU 1

4.0B 38.5A

CHZ009

HMS bus 1

CB_027

TBU 1

4.0B 38.5C

TBU 1

4.0B 38.5D

CHZ001

HMS bus 1
term

CB_030

TBU 0

1.0B 19.2L

TBU 0

1.0B 19.2E

CHZ001

TIMING bus 0

FU

FU

Position

Type

Use

Note

term.
CB_031

TBU 0

2.0B 19.2L

TBU 0

2.0B 19.2E

CHZ001

TIMING bus 0

term.
TIMING bus 0

CB_032

TBU 0

3.0B 19.2L

TBU 0

3.0B 19.2E

CHZ001

CB_033

TBU 0

4.0B 19.2L

TBU 0

4.0B 19.2E

CHZ001

TIMING bus 0
term

CB_034

TBU 1

1.0B 38.5L

TBU 1

1.0B 38.5E

CHZ001

TIMING bus 1
term.

term.

DN0938288
Issue 02D

Nokia Siemens Networks

33 (48)

Cable Lists for RNC2600

No

Cabinet

CB_035

CB_036
CB_037

CABLE TO
Position

Cabinet

CABLE FROM
Equip.

TBU 1

2.0B 38.5L

TBU 1

2.0B 38.5E

TBU 1

3.0B 38.5L

TBU 1

TBU 1

4.0B 38.5L

TBU 1

34 (48)

FU

FU

Nokia Siemens Networks

Use

Note

CHZ001

TIMING bus 1
term.

3.0B 38.5E

CHZ001

TIMING bus 1
term.

4.0B 38.5E

CHZ001

TIMING bus 1
term.

Position

Type

DN0938288
Issue 02D

Cable Lists for RNC2600

Figure 9

DN0938288
Issue 02D

Routing of timing cables in RNBC

Nokia Siemens Networks

35 (48)

Cable Lists for RNC2600

3.3

RNBC protection switch cables


Table 16

RNBC protection switch cables

CABLE FROM

CB_354

CB_371

CABLE TO
Position

Cabinet

No

Cabinet

Equip.

NPS1P 6

1.0B 16.4T

NPS1P 7

2.0B 16.4T

CIBS013

MSP1+1
Protection
Switch

NPS1P 6

1.0B 16.4E

NPS1P 7

2.0B 16.4E

CIBS013

LVDS lines
Protection
Switch

CB_370

NPS1P 6

1.0B 16.4J

NPS1P 7

2.0B 16.4J

CIBS013

LVDS lines
Protection
Switch

CB_357

NPS1P 6

1.0B 16.4R

NPS1P 7

2.0B 16.4R

CIBS013

MSP1+1
Protection
Switch

CB_356

NPS1P 6

1.0B 16.4P

NPS1P 7

2.0B 16.4P

CIBS013

MSP1+1
Protection
Switch

CB_355

NPS1P 6

1.0B 16.4G

NPS1P 7

2.0B 16.4G

CIBS013

MSP1+1
Protection
Switch

CB_358

NPS1P 8

1.0B 18.4T

NPS1P 9

2.0B 18.4T

CIBS013

MSP1+1
Protection
Switch

CB_373

NPS1P 8

1.0B 18.4E

NPS1P 9

2.0B 18.4E

CIBS013

LVDS lines
Protection
Switch

CB_372

NPS1P 8

1.0B 18.4J

NPS1P 9

2.0B 18.4J

CIBS013

LVDS lines
Protection
Switch

CB_361

NPS1P 8

1.0B 18.4R

NPS1P 9

2.0B 18.4R

CIBS013

MSP1+1
Protection
Switch

CB_360

NPS1P 8

1.0B 18.4P

NPS1P 9

2.0B 18.4P

CIBS013

MSP1+1
Protection
Switch

CB_359

NPS1P 8

1.0B 18.4G

NPS1P 9

2.0B 18.4G

CIBS013

MSP1+1
Protection
Switch

CB_362

NPS1P 10

3.0B 16.4T

NPS1P 11

4.0B 16.4T

CIBS013

MSP1+1
Protection
Switch

36 (48)

FU

FU

Nokia Siemens Networks

Position

Type

Use

Note

DN0938288
Issue 02D

Cable Lists for RNC2600

CABLE FROM

CB_375

CB_374

CABLE TO
Position

Cabinet

No

Cabinet

Equip.

NPS1P 10

3.0B 16.4E

NPS1P 11

4.0B 16.4E

CIBS013

LVDS lines
Protection
Switch

NPS1P 10

3.0B 16.4J

NPS1P 11

4.0B 16.4J

CIBS013

LVDS lines
Protection
Switch

CB_365

NPS1P 10

3.0B 16.4R

NPS1P 11

4.0B 16.4R

CIBS013

MSP1+1
Protection
Switch

CB_364

NPS1P 10

3.0B 16.4P

NPS1P 11

4.0B 16.4P

CIBS013

MSP1+1
Protection
Switch

CB_363

NPS1P 10

3.0B 16.4G

NPS1P 11

4.0B 16.4G

CIBS013

MSP1+1
Protection
Switch

CB_366

NPS1P 12

3.0B 18.4T

NPS1P 13

4.0B 18.4T

CIBS013

MSP1+1
Protection
Switch

CB_377

NPS1P 12

3.0B 18.4E

NPS1P 13

4.0B 18.4E

CIBS013

LVDS lines
Protection
Switch

CB_376

NPS1P 12

3.0B 18.4J

NPS1P 13

4.0B 18.4J

CIBS013

LVDS lines
Protection
Switch

CB_369

NPS1P 12

3.0B 18.4R

NPS1P 13

4.0B 18.4R

CIBS013

MSP1+1
Protection
Switch

CB_368

NPS1P 12

3.0B 18.4P

NPS1P 13

4.0B 18.4P

CIBS013

MSP1+1
Protection
Switch

CB_367

NPS1P 12

3.0B 18.4G

NPS1P 13

4.0B 18.4G

CIBS013

MSP1+1
Protection
Switch

CB_380

NPGEP 8 /

1.0B 15.4K

NPGEP 9 /

2.0B 15.4K

CHZS015

PIU_OK

FU

NPS1P 6
CB_381

NPGEP 10 /

NPGEP 12 /

1.0B 17.4K

NPGEP 14 /

3.0B 15.4K

NPGEP 8 /
NPS1P 6

DN0938288
Issue 02D

NPGEP 11 /

NPGEP 13 /

3.0B 17.4K

NPGEP 15 /

2.0B 17.4K

CHZS015

NPGEP 9 /
NPS1P 7

Nokia Siemens Networks

Note

PIU_OK

PAIR_OK
4.0B 15.4K

CHZS015

PIU_OK

PAIR_OK
4.0B 17.4K

CHZS015

NPS1P 13

1.0B 15.4L

Use

PAIR_OK

NPS1P 11

NPS1P 12

CB_390

Type

NPS1P 9

NPS1P 10
CB_383

Position

NPS1P 7

NPS1P 8
CB_382

FU

PIU_OK

PAIR_OK

2.0B 15.4L

CHZS015

Switchover

37 (48)

Cable Lists for RNC2600

No

Cabinet

CB_391

Position
1.0B 17.4L

FU
NPGEP 10 /

CABLE TO
Cabinet

CABLE FROM
Equip.

NPS1P 8
CB_392

NPGEP 12 /

NPGEP 14 /

3.0B 15.4L

NPGEP 11 /

3.0B 17.4L

Use

Note

2.0B 17.4L

CHZS015

Switchover

NPGEP 13 /

4.0B 15.4L

CHZS015

Switchover

NPGEP 15 /

4.0B 17.4L

CHZS015

Switchover

NPS1P 13

L3 Data Collector Cables for RNBC cabinet


Table 17

L3 Data Collector Cables for RNBC cabinet

No

Cabinet

CABLE TO
Cabinet

CABLE FROM
Equip.

Type

NPS1P 11

NPS1P 12

3.4

Position

NPS1P 9

NPS1P 10
CB_393

FU

CB_250

ICSU 14

1.0B 01.3B

CPLAN-A

CB_251

ICSU 15

1.0B 02.3B

CB_252

ICSU 16

1.0B 03.3B

CB_253

ICSU 17

CB_254

CB_255

Type

Use

Port 0

CHUS016

LAN EL0

CPLAN-A

Port 1

CHUS016

LAN EL0

CPLAN-A

Port 2

CHUS016

LAN EL0

1.0B 04.3B

CPLAN-A

Port 3

CHUS016

LAN EL0

ICSU 18

1.0B 05.3B

CPLAN-A

Port 4

CHUS016

LAN EL0

ICSU 19

1.0B 14.3B

CPLAN-A

Port 5

CHUS018

LAN EL0

CB_256

ICSU 20

2.0B 01.3B

CPLAN-A

Port 6

CHUS018

LAN EL0

CB_257

ICSU 21

2.0B 02.3B

CPLAN-A

Port 7

CHUS018

LAN EL0

CB_258

ICSU 22

2.0B 03.3B

CPLAN-A

Port 8

CHUS018

LAN EL0

CB_259

ICSU 23

2.0B 4.3B

CPLAN-A

Port 9

CHUS018

LAN EL0

CB_260

ICSU 24

2.0B 05.3B

CPLAN-A

Port 10

CHUS018

LAN EL0

CB_261

ICSU 25

2.0B 14.3B

CPLAN-A

Port 11

CHUS020

LAN EL0

CB_262

ICSU 26

3.0B 01.3B

CPLAN-A

Port 12

CHUS021

LAN EL0

CB_263

ICSU 27

3.0B 02.3B

CPLAN-A

Port 13

CHUS021

LAN EL0

CB_264

ICSU 28

3.0B 03.3B

CPLAN-A

Port 14

CHUS021

LAN EL0

CB_265

ICSU 29

3.0B 04.3B

CPLAN-A

Port 15

CHUS021

LAN EL0

CB_266

ICSU 30

3.0B 05.3B

CPLAN-A

Port 16

CHUS021

LAN EL0

38 (48)

FU

Position

FU

Nokia Siemens Networks

Position

Note

DN0938288
Issue 02D

Cable Lists for RNC2600

No

Cabinet

CABLE TO
Cabinet

CABLE FROM
Equip.

CB_267

ICSU 31

3.0B 14.3B

CPLAN-A

CB_268

ICSU 32

4.0B 01.3B

CB_269

ICSU 33

4.0B 02.3B

CB_270

ICSU 34

CB_271

CB_272
CB_273

Type

Use

Port 17

CHUS024

LAN EL0

CPLAN-A

Port 18

CHUS026

LAN EL0

CPLAN-A

Port 19

CHUS026

LAN EL0

4.0B 03.3B

CPLAN-A

Port 20

CHUS026

LAN EL0

ICSU 35

4.0B 04.3B

CPLAN-A

Port 21

CHUS026

LAN EL0

ICSU 36

4.0B 05.3B

CPLAN-A

Port 22

CHUS026

LAN EL0

ICSU 37

4.0B 14.3B

CPLAN-A

Port 23

CHUS028

LAN EL0

FU

DN0938288
Issue 02D

Position

FU

Nokia Siemens Networks

Position

Note

39 (48)

Cable Lists for RNC2600

Inter-cabinet cables from RNBC to


RNAC
This chapter details cabling from the RNBC cabinet to the RNAC cabinet
in RNC2600.

4.1

Inter-cabinet HMS and timing cables


The timing bus cable configuration shown on the table follows the star
topology. For information on the daisy chain topology, see Cable Lists
for RNC450
Table 18

Inter-cabinet HMS and timing cables from RNAC to RNBC

CB0_050

CB0_052

FU

Position

TBU 0

1.0B 19.2N

TBU 0

1.0B 19.2O

CB0_054

TBU 0

1.0B 19.2P

CB0_056

TBU 0

1.0B 19.2Q

CB0_051

CB0_053

TBU 1

TBU 1

2.0B 38.5N

CABLE TO
Cabinet

Equip.
No

Cabinet

CABLE FROM

Position

TBU 0

1.0B 19.2K

TBU 0

2.0B 19.2K

TBU 0

3.0B 19.2K

TBU 0

4.0B 19.2K

TBU 1

1.0B 38.5K

2.0B 38.5O
B

40 (48)

FU

TBU 1

Nokia Siemens Networks

2.0B 38.5K

Type

Use

CHZ016

TIMING bus 0

CHZ020

TIMING bus 0

Note

1)
2)
1)
2)

CHZ024

TIMING bus 0

CHZ028

TIMING bus 0

CHZ020

TIMING bus 1

CHZ016

TIMING bus 1

1)
2)
1)
2)
1)
2)
1)
2)

DN0938288
Issue 02D

Cable Lists for RNC2600

CB0_057

FU

Position

TBU 1

2.0B 38.5P

TBU 1

2.0B 38.5Q

Cabinet

CB0_055

CABLE TO

Cabinet

CABLE FROM
Equip.
No

CB0_040

TBU 1

3.0B 38.5K

TBU 1

4.0B 38.5K

Type

Use

CHZ020

TIMING bus 1

CHZ024

TIMING bus 1

TBU 0

1.0B 19.2A

1.0B 38.5A

1)
2)

2)
3) HMS term.

TBU 0

1.0B 19.2C

CHZ020

HMS bus 0

3.0B 38.5D
TBU 1

Note

1)

3.0B 19.2D

A
CB0_041

Position

B
A

FU

4) HMS to B-cabinet

3) HMS term.
A

TBU 1

1.0B 38.5C

CHZ020

HMS bus 1

4) HMS to B-cabinet

1) Default: Equipped at factory. Cables are bundled together and left unconnected if RNBC cabinet is not in the configuration.
2) Optional: If RNBC is in configuration these cables are connected to RNBC.
3) Default: Equipped at factory. Equip these terminating cables to sub rack 3 if RNBC cabinet is not in the configuration.
4) Optional: If RNBC is in configuration these cables are moved to RNBC subrack 1.

If the RNC2600 has the old daisy chain topology for timing bus cables,
see Cable Lists for RNC450.
The daisy chain cabling is identical for RNC450 and RNC2600, with
two exceptions:

DN0938288
Issue 02D

Concerning the inter-cabinet cable CB0_050 for Timing bus 0,


the cable type for this cable is CHZ015 in RNC450, and CHZ020
in RNC2600. Nonetheless, this cable is connected in the same
positions for both RNC450 and RNC2600. The cable type has no
effect to the configuration.

When the RNBC cabinet is added or removed, whether


expanding from capacity step 1, to step 2 or step 3; or
downgrading from step 2 or step 3, to step 1, the inter-cabinet
cables CB0_050 and CB0_051 for Timing buses 0 and 1 are
handled differently in RNC450 and RNC2600:
-

In RNC450, these two cables come attached to the


RNBC expansion cabinet.

In RNC2600, these two cables come with the RNAC


cabinet. In RNC2600, these two cables go as shown on
Table 20 Timing cables from RNBC to RNAC: daisy
chain.

Nokia Siemens Networks

41 (48)

Cable Lists for RNC2600

Table 19

FU

Position

1.0B 19.2K

3.0B 38.5E
TBU 1

CB0_051
B

FU

Position

Type

Use

3.0B 19.2E
TBU 0

CB0_050

CABLE TO
Cabinet

Cabinet

CABLE FROM
Equip.
No

Timing cables from RNBC to RNAC: daisy chain

TBU 0

TBU 1

1.0B 19.2N

2.0B 38.5N

CHZ020

CHZ020

Note

1)

Timing bus 0 term.

2)

Timing bus 0 to Bcabinet

1)

Timing bus 1 term.

2)

Timing bus 1 to Bcabinet

TIMING bus 0

TIMING bus 1

1.0B 38.5K

1)

Connect the terminating cables to subrack 3 if RNBC cabinet is not in the configuration.

2)

Optional: If RNBC cabinet is in the configuration, these cables are moved to RNBC subrack 1.

Note that if there is no RNBC cabinet in the configuration, all of these cables are in the RNAC cabinet.

42 (48)

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

RNBC

RNAC

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

38

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

38

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

38

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

38

DN05160893

= HMS bus 0
= HMS bus 1

Figure 10

DN0938288
Issue 02D

Routing of HMS cables

Nokia Siemens Networks

43 (48)

Cable Lists for RNC2600

Black = Timing Bus 0


Green = Timing Bus 1

Figure 11

44 (48)

Routing of Inter-cabinet timing cables

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

4.2

Inter-cabinet SWU LAN cables


Table 20

Inter-cabinet SWU LAN cables

CB0_107

CB0_106

CB0_105

CB0_104

CB0_103

CB0_102

CB0_101

CB0_100

CB0_115

CB0_114

CB0_113

CB0_112

CB0_111

CB0_110

CB0_109

CB0_108

CABLE TO

FU

Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

NPGE/NPGEP 15 /
NPS1/NPS1P 13
NPGE/NPGEP 14 /
NPS1/NPS1P 12
NPGE/NPGEP 13 /
NPS1/NPS1P 11
NPGE/NPGEP 12 /
NPS1/NPS1P 10
NPGE/NPGEP 11 /
NPS1/NPS1P 9
NPGE/NPGEP 10 /
NPS1/NPS1P 8
NPGE/NPGEP 9 /
NPS1/NPS1P 7
NPGE/NPGEP 8 /
NPS1/NPS1P 6

4.0B 17.4E

SWU 0

1.0B 5.5U

CIBS027

LAN

1)

3.0B 17.4E

SWU 0

1.0B 5.5S

CIBS021

LAN

1)

4.0B 15.4E

SWU 0

1.0B 5.5Q

CIBS027

LAN

1)

3.0B 15.4E

SWU 0

1.0B 5.5O

CIBS021

LAN

1)

2.0B 17.4E

SWU 0

1.0B 5.5M

CIBS018

LAN

1)

1.0B 17.4E

SWU 0

1.0B 5.5K

CIBS014

LAN

1)

2.0B 15.4E

SWU 0

1.0B 5.5H

CIBS018

LAN

1)

1.0B 15.4E

SWU 0

1.0B 5.5F

CIBS014

LAN

1)

NPGE/NPGEP 15 /
NPS1/NPS1P 13
NPGE/NPGEP 14 /
NPS1/NPS1P 12
NPGE/NPGEP 13 /
NPS1/NPS1P 11
NPGE/NPGEP 12 /
NPS1/NPS1P 10
NPGE/NPGEP 11 /
NPS1/NPS1P 9
NPGE/NPGEP 10 /
NPS1/NPS1P 8
NPGE/NPGEP 9 /
NPS1/NPS1P 7
NPGE/NPGEP 8 /
NPS1/NPS1P 6

4.0B 17.4G

SWU 1

2.0B 5.5U

CIBS021

LAN

1)

3.0B 17.4G

SWU 1

2.0B 5.5S

CIBS018

LAN

1)

4.0B 15.4G

SWU 1

2.0B 5.5Q

CIBS021

LAN

1)

3.0B 15.4G

SWU 1

2.0B 5.5O

CIBS018

LAN

1)

2.0B 17.4G

SWU 1

2.0B 5.5M

CIBS014

LAN

1)

1.0B 17.4G

SWU 1

2.0B 5.5K

CIBS018

LAN

1)

2.0B 15.4G

SWU 1

2.0B 5.5H

CIBS014

LAN

1)

1.0B 15.4G

SWU 1

2.0B 5.5F

CIBS018

LAN

1)

FU

Position

Type

Use

Note

1) Cables are connected before the BISFC back interface unit has been installed.

DN0938288
Issue 02D

Nokia Siemens Networks

45 (48)

Cable Lists for RNC2600

4.3

Inter-cabinet SFU LVDS lines


Table 21

Inter-cabinet SFU LVDS cables

CB0_200

CB0_201

CB0_202

CB0_203

CB0_204

CB0_205

CB0_206

CB0_207

CB0_208

CB0_209

CB0_210

CB0_211

CB0_212

CB0_213

CB0_214

CB0_215

CB0_216

CB0_217

CB0_218

CB0_219

46 (48)

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

MXU 8 /
BISFB
MXU 9 /
BISFB
MXU 10 /
BISFB
MXU 11 /
BISFB
MXU 12 /
BISFB
MXU13 /
BISFB
MXU 14 /
BISFB
MXU 15 /
BISFB

1.0B 9.B00

NPGE/NPGEP 8 /
NPS1/NPS1P 6
NPGE/NPGEP 9 /
NPS1/NPS1P 7
NPGE/NPGEP 10 /
NPS1/NPS1P 8
NPGE/NPGEP 11 /
NPS1/NPS1P 9
NPGE/NPGEP 12 /
NPS1/NPS1P 10
NPGE/NPGEP 13 /
NPS1/NPS1P 11
NPGE/NPGEP 14 /
NPS1/NPS1P 12
NPGE/NPGEP 15 /
NPS1/NPS1P 13

1.0B 15.B00 A

MXU 8 /
BISFB
MXU 9 /
BISFB
MXU 10 /
BISFB
MXU 11 /
BISFB

1.0B 9.B02

FU

1.0B 11.B00 A
2.0B 9.B00

2.0B 11.B00 A
3.0B 9.B00

3.0B 11.B00 A
4.0B 9.B00

4.0B 11.B00 A

2.0B 15.B00 A
1.0B 17.B00 A
2.0B 17.B00 A
3.0B 15.B00 A
4.0B 15.B00 A
3.0B 17.B00 A
4.0B 17.B00 A

1.0B 11.B02 A
2.0B 9.B02

2.0B 11.B02 A

FU

Position

Type

Use

Note

SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA

1.0B 2.B08

CSB018

LVDS lines

1)

1.0B 2.B09

CSB021

LVDS lines

1)

1.0B 2.B10

CSB022

LVDS lines

1)

1.0B 2.B11

CSB024

LVDS lines

1)

1.0B 2.B12

CSB028

LVDS lines

1)

1.0B 2.B13

CSB030

LVDS lines

1)

1.0B 2.B14

CSB032

LVDS lines

1)

1.0B 2.B15

CSB032

LVDS lines

1)

SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA
SFU 0 /
BISFA

1.0B 2.B24

CSB019

LVDS lines

1)

1.0B 2.B25

CSB025

LVDS lines

1)

1.0B 2.B26

CSB019

LVDS lines

1)

1.0B 2.B27

CSB025

LVDS lines

1)

1.0B 2.B28

CSB031

LVDS lines

1)

1.0B 2.B29

CSB034

LVDS lines

1)

1.0B 2.B30

CSB031

LVDS lines

1)

1.0B 2.B31

CSB034

LVDS lines

1)

SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA

2.0B 2.B08

CSB022

LVDS lines

1)

2.0B 2.B09

CSB024

LVDS lines

1)

2.0B 2.B10

CSB018

LVDS lines

1)

2.0B 2.B11

CSB021

LVDS lines

1)

Nokia Siemens Networks

DN0938288
Issue 02D

Cable Lists for RNC2600

CB0_220

CB0_221

CB0_222

CB0_223

CB0_224

CB0_225

CB0_226

CB0_227

CB0_228

CB0_229

CB0_230

CB0_231

CABLE TO
Position

Cabinet

Cabinet

CABLE FROM
Equip.
No

MXU 12 /
BISFB
MXU 13 /
BISFB
MXU 14 /
BISFB
MXU 15 /
BISFB

3.0B 9.B02

NPGE/NPGEP 8 /
NPS1/NPS1P 6
NPGE/NPGEP 9 /
NPS1/NPS1P 7
NPGE/NPGEP 10 /
NPS1/NPS1P 8
NPGE/NPGEP 11 /
NPS1/NPS1P 9
NPGE/NPGEP 12 /
NPS1/NPS1P 10
NPGE/NPGEP 13 /
NPS1/NPS1P 11
NPGE/NPGEP 14 /
NPS1/NPS1P 12
NPGE/NPGEP 15 /
NPS1/NPS1P 13

1.0B 15.B02 A

FU

3.0B 11.B02 A
4.0B 9.B02

4.0B 11.B02 A

2.0B 15.B02 A
1.0B 17.B02 A
2.0B 17.B02 A
3.0B 15.B02 A
4.0B 15.B02 A
3.0B 17.B02 A
4.0B 17.B02 A

FU

Position

Type

Use

Note

SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA

2.0B 2.B12

CSB022

LVDS lines

1)

2.0B 2.B13

CSB024

LVDS lines

1)

2.0B 2.B14

CSB028

LVDS lines

1)

2.0B 2.B15

CSB030

LVDS lines

1)

SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA
SFU 1 /
BISFA

2.0B 2.B24

CSB025

LVDS lines

1)

2.0B 2.B25

CSB019

LVDS lines

1)

2.0B 2.B26

CSB025

LVDS lines

1)

2.0B 2.B27

CSB019

LVDS lines

1)

2.0B 2.B28

CSB025

LVDS lines

1)

2.0B 2.B29

CSB031

LVDS lines

1)

2.0B 2.B30

CSB025

LVDS lines

1)

2.0B 2.B31

CSB031

LVDS lines

1)

1) Cables are connected after the BISFA, BISFB and BISFC back interface units have been installed. Insert the back interface unit
carefully. Check that the locking screws are closed properly, and that the back interface unit is in its place.

DN0938288
Issue 02D

Nokia Siemens Networks

47 (48)

Cable Lists for RNC2600

RNBC

RNAC

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

Figure 12

48 (48)

Routing of Inter-cabinet LVDS cables CB0_001 CB0_032

Nokia Siemens Networks

DN0938288
Issue 02D

You might also like