This document describes the process of configuring 7302ISAM for use in the
Cambodian project C5 Phase 3.
1
Compatibility
Conventions
3
3.1
Bold italics Arial font: denotes GUI actions (menu selections or buttons).
Pre-configuration steps
Connect to the ISAM via Craft Terminal
Connect the PCs Serial port to the craft port of the ISAM. The craft port is
located on the NANT-A card (RJ45 connector)
Run Hyperterminal (or other toools) and setup the serial connection with
following parameters:
Page 2 of 8
Choose C to enter the CLI. The factory username and password are:
Username = isadmin
Password = i$@mad-
Configuration Procedure
NT-I/O configuration:
Page 3 of 8
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
Page 4 of 8
4.8
4.9
Plan Equipment
Configure LT cards in the system.
# configure equipment slot 1/1/18 planned-type npot-b
capab-profile sip unlock no power-down
Note: The bold part needs to be replaced by the actual value found on the
node information sheet
Note: Each NPOT-B card should be configured according to above
commands
4.10 Save the configuration
# admin software-mngt shub database save
Note: System will save the configurations automatically every 5 minutes.
5
5.1
VoIP Part:
VLAN configuration
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
Note: x should be one port in NT-I/O card
5.2
VRF configuration
fast-path-mode:ena-user-user-com
Page 5 of 8
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
5.3
SIP configuration
5.4
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
5.5
Add terminations
# configure voice sip termination 1/1/1/2 directory-number 042215012 username pr_042215002@tc-voip.com.kh uri 042215012@tc-voip.com.kh md5-realm
auth.tc-voip.com.kh md5-password 042215012 admin-status up
Page 6 of 8
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
6. CDE profile part
1. Run 3cdaemon.exe, put official CDE file to the default path.
2. Set your PC IP to 192.168.2.x
3. Open a CLI session to ISAM by telnet.
CLI commands:
# admin software-mngt cdeprof download 192.168.2.x:MSR2SC41.003
Wait for transfer completed, then
# admin software-mngt cdeprof activate MSR2SC41.003
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
7. XDSL part
7.1 NALT-E configuration:
# configure vlan shub id 901 mode residential-bridge user2-comm disable
# configure vlan shub id 901 egress-port lt:1/1/9
# configure vlan shub id 901 egress-port network:x
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
Note: Each NALT-E card should be configured according to above commands
Note: x should be one port in NT-I/O card
7.2 Line data configuration:
# configure atm pvc 1/1/9/1:0:35
# configure bridge port 1/1/9/1:0:35 max-unicast-mac 8
# configure bridge port 1/1/9/1:0:35 vlan-id 901
# configure bridge port 1/1/9/1:0:35 pvid 901
# configure interface port vlan-port:1/1/9/1:0:35:901 admin-up severity novalue
# configure interface port xdsl-line:1/1/9/1 admin-up
Note: The bold part needs to be replaced by the actual value found on the node
information sheet