You are on page 1of 16

Air-to-Water Heat Pumps with Integrated Hydronic Module

AQUASNAP

Carrier is participating in
the Eurovent Certification
Programme. Products are
as listed in the Eurovent
Directory of Certified
Products.

30RH 040-240 A
Nominal cooling capacity 37-213 kW
Nominal heating capacity 39-227 kW

The 30RH Aquasnap heat pumps feature the latest technological innovations: ecological refrigerant HFC-407C,
scroll compressors, low-noise fans made of a composite
material and microprocessor control. The refrigerant circuit
with its patented receiver/heat exchanger, and the autoadaptive Pro-Dialog control system guarantee reliable and
economical operation in all climates from -10C to 45C.
Aquasnap includes a complete hydronic module as standard, simplifying the installation to straightforward operations like connection of the power supply and the water
supply and return piping.
Features
Integrated hydronic module for fast installation, incorporating all hydronic components: removable screen filter, water
pump with high available pressure, expansion tank, water
flow switch, safety valve, pressure gauges, and purge valve.
A throttle valve allows adjustment of the water flow in
accordance with the characteristics of the installation. All
components are protected against frost down to -20C.
Low-volume water loop: the auto-adaptive algorithm controls the water temperature and eliminates any risk of
excessive compressor cycling. In the majority of comfort
air conditioning applications a buffer tank is unnecessary.
The low water volume reduces the energy consumption
during changeover from heating to cooling during inbetween seasons.

Ecological refrigerant HFC-407C: no effect on the ozone


layer, replaces R-22 in air conditioning applications with
small and medium capacities. Extensively tested by Carrier
for several years, it offers the same performance and reliability guarantees as R-22.
The receiver/heat exchanger (Carrier patent) enhances reliability and performance of the 30RH heat pump. In the heating mode the refrigerant is condensed in the receiver at the
plate heat exchanger outlet. This device compensates for
large differences in volume between the coil and the water
heat exchanger (plate heat exchanger). It ensures an ideal
refrigerant charge in heating and cooling mode and perfect
control of subcooling or superheating. Compressor life is
increased (no risk of refrigerant migration into the compressor), and the use of the heat exchangers is maximised.
The revolutionary, low-noise, two-speed Flying Bird II fan
is made of composite recyclable material and employs a
multi-blade design and a rotating shroud, as used in the
aeronautical industry. It is exceptionally quiet, and does not
generate the low-frequency noise, irritating to the human
ear. At part load or low outdoor temperatures the fan automatically switches to the low speed. To reduce the operating noise even further, the fan is not fixed to the top unit
panel, but supported by an extremely rigid tower chassis.
Defrost is optimised by the auto-adaptive algorithm. This
and the new coil design reduce the defrost cycle duration by
an average of 50%. For increased safety an electric heater
prevents accumulation of ice on the air heat exchanger
base.

Quiet, vibration-free scroll compressors, durable and


maintenance-free. The use of several compressors per
circuit (from size 30RH 050) reduces the start-up current
and the power consumption at part load.
The refrigerant circuit is completely leak-proof for life. All
pipes and refrigeration components are welded. Pressure
sensors, mounted directly on the pipes, take the place of the
pressure switches and their capillary tubes, a source of
leaks in the past.
From size 30RH 090 upwards, two independent refrigerant
circuits ensure partial cooling/heating capacity in all
circumstances.
Electrical connections are simplified, and the standard
Aquasnap equipment includes a main disconnect switch,
and a single entry point of the three-phase without neutral
power supply to the whole unit.
Large removable panels and the hinged door of the control
box ensure perfect accessibility and permit easy access to
all components. Furthermore an opening allows
adjustments to be made without interrupting the operation
of the unit. For the most important maintenance operations
the unit top cover is easily removed, and total access from
above is possible, with the fan remaining in place.
The electric resistance heater control module (accessory)
permits control of up to four stages of electric heat for
supplementary heating at low outdoor temperatures.
The evaporator is a welded, stainless steel plate heat
exchanger, maximising the thermodynamic properties of
HFC-407C and offering considerably increased
performances as well as low water-side pressure drops.
From size 30RA 090 upwards the units are equipped with a
twin-circuit interlaced heat exchanger for safe operation at
part load. When the unit is shut down, the heat exchanger is
protected against freeze-up by a trace heater.

PRO-DIALOG Plus control


PRO-DIALOG Plus is an advanced numeric control system
that combines complex intelligence with great operating
simplicity. PRO-DIALOG Plus constantly monitors all
machine parameters, optimising the operation of
compressors, fans, cycle reversing valve and water pump.

A powerful control system


The Pro-Dialog Plus control is auto-adaptive and
guarantees total protection of the compressors. The system
permanently checks the operating parameters and responds
to avoid excessive cycling and maintain the ideal operating
range for the compressor (temperatures and pressures out of
range etc.). By taking corrective action before the fault
occurs, the auto-adaptive control frequently prevents a
shutdown of the heat pump due to a fault condition.
To optimise power consumption, PRO-DIALOG Plus
automatically resets the chilled water temperature set-point
in accordance with the outdoor air temperature or the return
water temperature or uses a second set-point (example
occupied/unoccupied) and ensures automatic heating/
cooling changeover.
The system also controls the start-up of a boiler relay or
manages a supplementary electric heater (accessory).
Clear and easy-to-use control system
The operator interface is clear and user-friendly: LEDs and
two numeric displays ensure immediate verification of all
unit operating data.
Buttons conveniently positioned on a synoptic heat pump
diagram offer immediate display of the operating
parameters: temperatures, pressures, set point, run times
etc.
10 menus offer direct access to all machine controls,
including a history of possible faults, for rapid and
complete heat pump fault diagnosis.
Extended communications capabilities
PRO-DIALOG Plus allows remote control. Volt-free
contacts regulate: start/stop, cooling/heating mode
selection, power demand limit or selection of the second set
point. The system permits remote signalling of any possible
anomaly for each refrigerant circuit.
The CCN Clock Board option/accessory ensures the time
schedule programming of the heat pump:
- start/stop,
- operation at the second set point (e.g. unoccupied mode),
- low-speed fan operation (e.g. during the night).
This option/accessory also controls the operation of two
units in parallel and offers a serial RS 485 communication
port.

PRO-DIALOG Plus operator interface

Options and accessories


Option
Condenser anti-corrosion pre-treatment for marine applications

Accessory

Electronic compressor starter for reduction of start-up current (30RH 040-080)

Unit without hydronic module

Hydronic module with dual pump

CCN Clock Board time scheduling and communications board

Time scheduling and communications board for the Aquasmart system

Supplementary electric resistance heater control board (3 stages + 1 emergency stage)

RS485 communications interface with open JBus protocol

21
6
5
20

4
2

8
3
1
Legend

24
9

Components of unit and hydronic module


1
Victaulic screen filter
2
Expansion tank
3
Safety valve
4
Available pressure pump
5
Purge valve and pressure tap (see Installation Manual)
6
Pressure gauge to measure the plate heat exchanger
pressure drop (to be isolated with valve No. 5 if not used)
7
System air vent
8
Flow switch
9
Flow control valve
10 Plate heat exchanger
11 Evaporator defrost heater

14
22

16
23
Hydronic module (040 to 160)

2
17

12
14

15

10

4
13

5
18

11

7
5

17
13

14

15

Installation components
12 Air vent
13 Thermometer sleeve
14 Flexible connection
15 Check valve
16 System water drain plug (on connection pipe supplied in
the unit)
17 Pressure gauge
18 Freeze-up protection bypass valve (when valves No. 15
are closed during winter)
19 Charge valve
20
Plate heat exchanger outlet
21
Plate heat exchanger inlet
22
Water inlet
23
Water outlet
24
Customer connection sleeves for welded or screw
connection (supplied)
------ Hydronic module (units with hydronic module)
Note: Units without hydronic module (option) are equipped with
a flow switch and an internal piping heater.

19
16
Typical hydronic circuit diagram (040 to 160)

Physical data
30RH

040

050

060

070

080

090

100

120

140

160

200

240

kW

38.2

44.5

54

66

72

83

93

109

133

143

180

213

kW

37

43.4

53

65

71

83

92

107

132

142

180

213

kW

39.3

47.3

58

66

80

86

97

116

133

160

192

227

kW

40.4

48.3

59

67

80

87

98

117

134

160

192

227

Operating weight, with hydronic module kg


Single pump
Dual pump
kg
Unit without hydronic module

566
646
542

624
704
600

647
727
623

661
741
637

691
768
665

1183
1260
1152

1196
1273
1165

1238
1338
1200

1312
1412
1274

1368
1468
1330

2233
2321
2086

2405
2493
2258

Refrigerant charge
Circuit A
Circuit B

kg
kg

R-407C
10.9
11.5
-

15.1
-

16.7
-

19.5
-

10.9
11.5

10.9
15.1

15.1
15.1

16.7
16.7

19.5
19.5

22.5
29.5

29.5
29.5

Hermetic scroll compressor, 48.3 r/s


1
2
2
2
1
2
2
2
100
46
42
50

2
2
50

1
2
3
25

1
2
3
25

2
2
4
21

2
2
4
25

2
2
4
25

2
3
5
20

3
3
6
16.5

Net nominal cooling capacity,


single pump*
Net nominal cooling capacity,
dual pump*
Net nominal heating capacity,
single pump**
Net nominal heating capacity,
dual pump**

Compressors
Quantity, circuit A
Quantity, circuit B
No. of capacity steps
Minimum capacity
Control type

PRO-DIALOG Plus

Air heat exchangers


Fans
Quantity
Total air flow (high speed)
Speed (high/low speed)

Grooved copper tubes, aluminium fins


Axial Flying Bird II fans with rotating shroud
1
1
1
1
1
2
2
2
2
2
4
4
3870
3660
4080
5600
5600
7350
7950
8160
11200 11200 17343 20908
11.5/5.8 11.5/5.8 11.5/5.8 15.6/7.8 15.6/7.8 11.5/5.8 11.5/5.8 11.5/5.8 15.6/7.8 15.6/7.8 11.5/5.8 15.6/7.8

Water heat exchangers


Water volume
Max. water-side operating pressure
Option without hydronic module
Unit with hydronic module

l/s
r/s
l
kPa

Hydronic module
Pump (single centrifugal)
Quantity
Expansion tank volume
Water connections
(with and without hydronic module)
Diameter
Outside tube diameter

Direct-expansion welded plate heat exchanger


3.6
4.6
5.9
6.5
7.6
7.2

8.2

9.8

11.4

13.0

26.8

26.8

1000
300

1000
300

1000
300

1000
300

1000
300

1000
400

1000
400

1000
300

1000
300

1000
300

1000
300

1000
300

Pump, safety valve, expansion tank, flow switch and flow control throttle valve
Victaulic screen filter, one pressure gauge (two for sizes 200 + 240), purge valves (water and air)
Monocell composite pump, 48.3 r/s
Monocell pump,
48.3 r/s
1
1
1
1
1
1
1
1
1
1
1
1
12
12
12
12
12
35
35
35
35
35
50
50
Victaulic (sleeves for welding or screw connections supplied)

in
mm

2
60.3

2
60.3

2
60.3

2
60.3

2
60.3

2
60.3

2
60.3

2-1/2
76.1

2-1/2
76.1

2-1/2
76.1

Threaded male
gas connections
3
3
88.9
88.9

Legend
* Net nominal cooling capacity based on Eurovent conditions = gross cooling capacity plus the capacity corresponding to the available pressure (flow x pressure/0.3).
Standard Eurovent conditions: water heat exchanger entering/leaving temperature 12C/7C, outdoor air temperature 35C.
** Net nominal heating capacity based on Eurovent conditions = gross heating capacity minus the capacity corresponding to the available pressure (flow x pressure 0.3).
Standard Eurovent conditions: air heat exchanger entering/leaving temperature 40C/45C, outdoor air dry bulb temperature 7C with 87% relative humidity.

Sound levels
Sound power, dB(A) 10-12 W

040

050

060

070

080

090

100

120

140

160

200

240

82

82

82

86

87

85

85

85

89

90

91

92

According to Eurovent 8/1 (derived from ISO standard 3744 or ISO 9614-1).

Electrical data
30RH
Power circuit
Nominal power supply
Voltage range

040
V-ph-Hz
V

Control circuit supply

050

060

070

080

090

100

120

140

160

200

240

400-3-50
360-440
The control circuit is supplied via the unit-mounted transformer

Maximum unit power input*

kW

20.3

24.6

28.9

33.9

40.0

44.1

48.4

58.1

68.1

79.7

104.3

124.9

Nominal unit current draw**

30.0

35.6

42.2

51.0

57.2

64.5

71.1

85.2

102.9

113.2

151.0

179.1

Maximum unit current draw***

35.0

42.6

49.3

58.2

67.2

76.5

83.2

99.4

117.2

133.2

176.0

209.1

Maximum start-up current standard unit

181

153

159

168

213

222

229

209

227

279

322

355

With electronic starter option

119

107

112

120

151

Three-phase short circuit holding current

kA

10

10

10

10

10

10

10

10

10

10

10

10

Legend
* Power input of the compressor(s) + fan(s) + pump at maximum unit operating conditions: entering/leaving water temperature = 15C/10C and maximum air entering temperature of 45C 1 K
depending on the unit, and 400 V nominal voltage (values given on the unit name plate).
** Nominal unit current draw at standard Eurovent conditions: evaporator entering/leaving water temperature 12C/7C, outdoor air temperature 35C. The current values are given at 400 V
nominal voltage.
*** Maximum unit operating current at maximum unit power input and 400 V nominal voltage (values given on the unit name plate)
Maximum instantaneous starting current at 400 V nominal voltage and with compressor in across-the-line-start (maximum operating current of the smallest compressor(s) + fan(s) current +
pump current + locked rotor current of the largest compressor).
Maximum instantaneous starting current at 400 V nominal voltage and with compressor with electronic starter (maximum operating current of the smallest compressor(s) + fan(s) current +

Electrical data notes:


30RH 040-240 units have a single power connection point located at the main
switch.
The control box includes the following standard features:
- a main disconnect switch, starter and motor protection devices for each
compressor, the fan, the optional pumps
- the control devices
Field connections:
All connections to the system and the electrical installations must be in full
accordance with all applicable local codes.
The Carrier 30RH units are designed and built to ensure conformance with
these codes. The recommendations of European standard EN 60204-1
(corresponds to IEC 60204-1) (machine safety - electrical machine
components - part 1: general regulations) are specifically taken into account,
when designing the electrical equipment.
NOTES:
Generally the recommendations of IEC 60364 are accepted as compliance
with the requirements of the installation directives. Conformance with EN 60
204 is the best means of ensuring compliance with the Machines Directive
1.5.1.
Annex B of EN 60204-1 describes the electrical characteristics used for the
operation of the machines.
1. The operating environment for the 30RH units is specified below:
a. Environment* - Environment as classified in EN 60721 (corresponds to IEC
60721):
- outdoor installation*

- ambient temperature range: -10C to +45C 1 K, class 4K3*


- altitude: 2000 m
- presence of hard solids, class 4S2 (no significant dust present)
- presence of corrosive and polluting substances, class 4C2 (negligible)
- vibration and shock, class 4M2
b. Competence of personnel, class BA4* (trained personnel - IEC 60364)
2. Power supply frequency variation: 2 Hz.
3. The neutral (N) conductor must not be connected directly to the unit (if
necessary use transformers)
4. Over-current protection of the power supply conductors is not provided with
the unit.
5. The factory-installed disconnect switches/circuit breakers are of a type that
is suitable to interrupt the power in accordance with EN60947-3 (corresponds
to IEC 60947-3).
6. The units are designed for connection to TN networks (IEC 60364). For IT
networks the earth connection must not be at the network earth. Provide a
local earth, consult competent local organisations to complete the electrical
installation.
NOTE:
If particular aspects of an actual installation do not conform to the
conditions described above, or if there are other conditions which
should be considered, always contact your local Carrier representative.
* The required protection level for this class is IP43BW (according to reference
document IEC 60529). All 30RH units are protected to IP44CW and fulfil this
protection condition.

Operating limits
Heat exchanger water flow rate, l/s
30RH

Min. water flow

040
050
060
070
080
090
100
120
140
160
200
240

1.0
1.1
1.4
1.5
1.7
2.3
2.6
3.1
3.5
4.2
5.3
6.3

Max. water flow*


Single pump

Dual pump

Max. water flow**

3.5
4.0
4.4
4.6
5.5
5.6
5.8
8.5
8.8
9.1
23.4
23.4

4.4
5.2
6.0
6.4
6.8
6.9
7.4
10.5
11.4
11.9
23.4
23.4

3.7
4.6
5.8
6.4
7.3
7.6
8.8
10.8
12.7
14.4
24.2
24.2

Heating mode
30RH
040 - 240

Entering water temperature


at start-up, C

Entering water temperature


at shut-down, C

Leaving water temperature


during operation, C

Entering air temperature, C

Minimum

Maximum

Minimum

Maximum

Minimum

Maximum

Minimum

Maximum

10

45

60

20

50

-10

40

Cooling mode
30RH
040 - 240

Entering water temperature


at start-up, C

Entering water temperature


at shut-down, C

Leaving water temperature


during operation, C

Entering air temperature, C

Minimum ,

Maximum

Maximum

Minimum

Maximum

Minimum

Maximum

7,8

30

60

15

-10

46

Notes:
* Maximum flow rate for an available pressure of 50 kPa (unit with hydronic module)
** Maximum flow rate for a pressure drop of 100 kPa (unit without hydronic module)
For applications requiring operation below 7.8C contact Carrier S.A.
For applications requiring operation below 5C, anti-freeze must be used in the units

Operating range in cooling mode

Operating range in heating mode

C
46

40

30
25
Entering air temperature

Entering air temperature

35
45
44.5
44

20
15
10
5
0
-5

-10
-10
0

Leaving water temperature

10

C
20
35
25
30
40
Leaving water temperature

Notes:
1. Water heat exchanger t = 5 K
2. The water heat exchanger and the hydronic module are protected against frost down to -20C.
Operating range with required anti-freeze solution and special Pro-Dialog control configuration

45

50

Available static system pressure


Single pump
325
300
275
250

Available static pressure, kPa

225
200
175
150
125
100
75
4
50
1

25
0

Legend
1 30RH 040
2 30RH 050
3 30RH 060
4 30RH 070
5 30RH 080-090

6
7
8
9
10

6
6

10

10
12
Water flow rate, l/s

14

16

18

20

22

24

30RH 100
30RH 120
30RH 140
30RH 160
30RH 200-240

Dual pump
325
300
275

Available static pressure, kPa

250
225
200
175
150
125
100
7
75

50
1

25
0
Legend
1 30RH 040
2 30RH 050
3 30RH 060
4 30RH 070
5 30RH 080
6 30RH 090

5
8

10

10
12

11
14

Water flow rate, l/s


7
8
9
10
11

30RH 100
30RH 120
30RH 140
30RH 160
30RH 200-240

16

18

20

22

24

Water loop volume


Minimum water loop volume

Maximum water loop volume

Volume = CAP (kW) x N* = litres, where CAP is the


nominal cooling capacity at nominal operating conditions.

Units with hydronic module incorporate an expansion tank


that limits the water loop volume. The table below gives the
maximum loop volume for pure water or ethylene glycol
with various concentrations.

Air conditioning application

N*

30RH 040
30RH 050 to 240

3.5
2.5
Pure water
10% ethylene glycol
20% ethylene glycol
35% ethylene glycol

Industrial process cooling


30RH 040 to 240

See note

30RH
040-080
(in litres)

30RH
090-160
(in litres)

30RH
200-240
(in litres)

600
450
400
300

1500
1200
1000
800

2000
1600
1400
1000

NOTE:
For industrial process cooling applications, where high stability of the water
temperature must be achieved, the values above must be increased.

Dimensions/clearances
30RH 040-080

2071

1329

1329

1081

1000

1000

Legend:
All dimensions are given in mm.

Control box
Required clearances for air entry
1

Required clearances for maintenance

Water inlet
1000

2
1000

Water outlet
Power cable entry
Air outlet, do not obstruct

NOTE:
Drawings are not contractually binding.
Before designing an installation, consult the
certified dimensional drawings, available on
request.

Dimensions/clearances
30RH 090-160

2278

1000

1329

2071

1
1

1
1000

1
1000

1000

30RH200-240

3318

1674

2279

1000

Legend:
All dimensions are given in mm.
1

Control box
Required clearances for air entry

Required clearances for maintenance


Water inlet
2

Water outlet
Power cable entry
Air outlet, do not obstruct

1000

1000

2
1000

NOTE:
Drawings are not contractually binding. Before designing an installation,
consult the certified dimensional drawings, available on request.

Heating capacities, single pump


LWT

30RH

Entering air temperature, C


-10
CAP

C kW

-5
COMP UNIT

COND

PRES CAP

0
COMP UNIT

COND

PRES CAP

7
COMP UNIT

COND

PRES CAP

10
COMP UNIT

COND

PRES CAP

COMP UNIT

COND

PRES

kW

kW

l/s

kPa kPa

kW

kW

kW

l/s

kPa kPa

kW

kW

kW

l/s

kPa kPa

kW

kW

kW

l/s

kPa kPa

kW

kW

kW

l/s

kPa kPa

8.79
11.3
13.4
14.7
18
20.1
22.2
26.8
29.5
36
46.5
60

10.5
12.9
14.8
17.5
20.5
22.4
24.3
29.4
34.6
40.7
56
72

1.09
1.32
1.62
1.85
2.22
2.41
2.71
3.25
3.71
4.44
5.48
6.59

10
9
9
9
10
13
12
12
11
13
7
10

162
162
161
159
199
193
188
217
213
203
282
275

26.3
31.8
38.8
44.2
53
57
64
77
88
105
137
157

8.85
11.4
13.5
14.9
18.1
20.2
22.4
27
29.7
36.2
47.6
60

10.5
12.9
14.8
17.5
20.5
22.4
24.4
29.3
34.5
40.7
56
72

1.24
1.51
1.85
2.12
2.53
2.75
3.09
3.71
4.23
5.07
6.57
7.52

13
12
11
12
13
16
16
15
15
16
10
13

159
159
157
154
191
184
177
210
204
190
275
268

31.2
37.9
46.2
53
63
68
77
92
105
126
162
186

9.22
11.8
14
15.5
18.9
21.1
23.3
28.1
31
37.7
49.3
63

10.8
13.2
15.2
18
21.1
23.1
25.2
30.1
35.5
42.1
57
73

1.48
1.81
2.21
2.53
3.03
3.29
3.69
4.43
5.06
6.06
7.8
8.98

18
17
16
17
19
23
22
21
20
22
13
17

153
152
149
143
175
166
156
196
187
165
265
255

42.2
54
63
70
85
96
105
125
140
171
202
245

10.1
12.5
14.8
16.9
19.9
22.7
24.9
29.6
33.7
39.7
47.2
57

11.5
13.7
15.9
19.3
22.1
24.9
27.2
31.4
38.3
45
54
67

2.01
2.6
3.01
3.36
4.09
4.61
5.02
6.02
6.72
8.17
9.74
11.9

33
35
29
30
35
43
38
37
34
39
20
29

136
126
123
114
132
107
96
152
138
90
248
226

45.7
58
67
76
91
103
113
134
152
184
214
263

10.3
12.7
15
17.1
20.1
23
25.3
30
34.3
40.3
47.6
58

11.7
13.9
16.1
19.6
22.5
25.4
27.8
32
39.1
46.1
54
67

2.18
2.77
3.23
3.64
4.39
4.95
5.41
6.46
7.27
8.78
10.3
12.7

39
39
34
36
40
49
44
42
39
44
23
33

129
119
114
101
117
89
75
137
118
64
243
216

040 35 22.8 9.67


050
27.6 12.4
060
33.6 14.7
070
38.2 16.3
080
45.6 19.8
090
49.4 22.1
100
55
24.4
120
67
29.4
140
76
32.6
160
91
39.6
200
114 51
240
136 65

11.4
14
16.1
19
22.4
24.4
26.5
32
37.6
44.3
61
77

1.07
1.3
1.6
1.83
2.19
2.37
2.67
3.2
3.65
4.37
5.4
6.49

9
9
8
9
10
12
12
11
11
12
7
10

162
162
162
159
200
194
189
218
214
204
283
276

25.9
31.4
38.3
43.6
52
56
63
76
87
104
136
155

9.74
12.5
14.8
16.4
19.9
22.2
24.5
29.6
32.8
39.9
53
66

11.4
14
16.1
19
22.4
24.4
26.6
31.9
37.6
44.4
61
77

1.22
1.49
1.83
2.09
2.5
2.71
3.05
3.66
4.18
5
6.49
7.42

12
11
11
12
13
16
15
15
14
16
10
12

159
159
158
154
191
185
178
211
205
191
276
269

30.9
37.4
45.7
52
62
67
76
91
104
124
161
184

10.1
12.9
15.3
17
20.7
23
25.4
30.7
34
41.4
54
68

11.7
14.3
16.5
19.5
23
25.1
27.4
32.7
38.6
45.7
62
78

1.46
1.79
2.19
2.5
2.99
3.25
3.65
4.38
5
5.99
7.72
8.88

17
16
16
17
19
22
21
21
20
22
13
17

154
153
150
144
176
167
157
197
188
166
266
256

40.9
52
61
69
82
92
102
122
137
165
198
238

11.2
13.9
16.5
18.7
22.1
25.1
27.6
32.9
37.3
44.2
52
63

12.6
15.2
17.5
21.1
24.3
27.2
29.8
34.7
41.9
49.3
59
73

1.95
2.47
2.92
3.31
3.96
4.42
4.87
5.85
6.61
7.92
9.54
11.5

31
31
28
29
33
40
36
35
33
37
20
28

138
132
126
116
138
117
103
158
142
100
250
230

44.4
55
66
75
89
99
110
131
149
179
209
256

11.3
14.1
16.7
18.9
22.4
25.5
28
33.4
37.9
44.8
53
64

12.7
15.4
17.8
21.4
24.7
27.7
30.4
35.3
42.6
50
59
73

2.12
2.64
3.14
3.58
4.26
4.75
5.26
6.29
7.16
8.53
10.1
12.4

37
36
32
34
38
45
42
40
38
42
22
32

131
125
118
104
124
100
83
143
122
75
245
220

040 40 22.2 10.7


050
26.9 13.7
060
32.7 16.2
070
37.2 18.1
080
44.4 21.9
090
48.1 24.4
100
54
26.9
120
65
32.5
140
74
36.2
160
88
43.9
200
112 57
240
132 72

12.5
15.3
17.7
20.8
24.6
26.8
29.1
35.1
41.3
48.7
67
84

1.04
1.27
1.56
1.78
2.13
2.31
2.6
3.11
3.55
4.25
5.31
6.31

9
8
8
8
9
12
11
11
11
12
7
9

162
163
162
160
201
196
191
219
215
206
283
277

25.3
30.7
37.4
42.6
51
55
62
74
85
101
134
151

10.8
13.8
16.3
18.2
22.1
24.6
27.1
32.6
36.4
44.1
58
72

12.4
15.3
17.7
20.8
24.5
26.8
29.1
35
41.3
48.7
67
83

1.19
1.46
1.78
2.04
2.44
2.65
2.98
3.57
4.08
4.88
6.4
7.24

12
11
10
11
12
15
14
14
14
15
9
12

160
160
159
155
193
187
180
212
207
194
276
270

30.3
36.7
44.8
51
61
66
74
89
102
122
159
181

11.1
14.2
16.9
18.8
22.8
25.4
28
33.7
37.7
45.6
60
74

12.7
15.6
18.1
21.3
25.1
27.4
29.9
35.8
42.2
50
68
85

1.43
1.75
2.15
2.45
2.93
3.18
3.58
4.29
4.9
5.87
7.63
8.71

17
16
15
16
18
21
20
20
19
21
13
16

155
154
151
146
178
169
160
199
190
170
267
258

40
49.2
59
68
81
89
99
119
135
162
194
232

12.3
15.5
18.3
20.7
24.7
27.8
30.7
36.6
41.3
49.4
58
70

13.8
16.7
19.4
23.1
26.9
29.9
32.8
38.4
45.9
54
65
80

1.9
2.35
2.85
3.25
3.88
4.26
4.76
5.7
6.5
7.75
9.38
11.2

30
28
26
28
31
37
35
34
32
35
19
26

140
136
129
119
142
125
109
162
146
107
252
233

43.4
53
64
73
87
96
107
128
147
175
206
250

12.5
15.7
18.5
20.9
25
28.2
31
37.1
41.9
49.9
59
71

13.9
16.9
19.6
23.4
27.2
30.4
33.4
38.9
46.6
55
65
80

2.07
2.52
3.07
3.52
4.18
4.59
5.14
6.15
7.05
8.36
9.96
12.1

35
33
31
33
37
43
40
38
37
40
21
30

133
129
121
107
128
108
89
148
126
82
246
224

040 45 050
060
070
080
090
100
120
140
160
200
240
-

24.5
29.6
36.1
41.1
49.1
53
60
72
82
98
132
146

12
15.3
18.1
20.3
24.5
27.3
30.1
36.1
40.5
49.1
65
79

13.7
16.8
19.5
22.9
27
29.5
32.1
38.6
45.5
54
74
91

1.15
1.41
1.72
1.97
2.36
2.56
2.87
3.45
3.93
4.71
6.3
6.99

11
10
10
10
12
14
14
13
13
14
9
11

161
161
160
157
195
189
184
214
209
198
277
272

29.4
35.7
43.5
49.6
59
64
72
87
99
118
157
176

12.3
15.7
18.6
20.9
25.3
28.1
30.9
37.2
41.8
51
66
81

13.9
17.2
19.8
23.4
27.6
30.1
32.9
39.3
46.4
55
75
92

1.39
1.7
2.08
2.38
2.85
3.09
3.48
4.17
4.76
5.7
7.53
8.46

16
15
14
15
17
20
19
19
18
20
13
16

156
155
152
148
181
173
164
201
193
174
268
260

39.3
47.3
58
66
80
86
97
116
133
160
192
227

13.7
17.1
20.3
22.9
27.5
30.8
34
40.7
45.8
55
65
78

15.1
18.4
21.4
25.3
29.7
32.8
36.1
42.5
50
60
72
87

1.87
2.26
2.79
3.19
3.83
4.13
4.66
5.58
6.38
7.66
9.28
11

29
26
25
27
31
35
33
32
31
35
19
25

141
139
131
121
144
131
114
166
149
111
253
236

42.8
51
63
72
86
93
105
125
144
173
204
245

13.8
17.3
20.6
23.2
27.8
31.2
34.4
41.1
46.3
56
65
79

15.2
18.6
21.6
25.6
30.1
33.3
36.7
43
51
61
72
88

2.04
2.43
3.01
3.46
4.13
4.47
5.05
6.03
6.93
8.27
9.86
11.8

34
30
29
32
36
40
39
37
36
40
21
29

135
133
123
109
130
114
94
152
131
86
247
226

040 50 050
060
070
080
090
100
120
140
160
-

28.3
34.3
41.9
47.7
57
62
69
83
95
114

13.7
17.4
20.6
23.3
28.1
31.1
34.3
41.2
46.5
56

15.3
18.9
21.9
25.8
30.4
33.2
36.2
43.4
51
61

1.34
1.63
2
2.29
2.74
2.97
3.34
4.01
4.58
5.48

15
14
13
14
16
19
18
17
17
19

157
157
154
150
184
177
169
204
197
180

38.9
45.8
57
65
80
84
96
114
130
160

15.1
18.9
22.5
25.3
30.7
34
37.7
45.1
51
61

16.6
20.2
23.6
27.7
32.9
36.1
39.7
46.9
55
66

1.86
2.19
2.75
3.13
3.82
4.05
4.6
5.49
6.25
7.65

28
25
25
26
30
34
33
31
30
34

142
141
133
123
144
135
117
168
153
111

42.4
49.3
62
71
86
91
104
123
142
173

15.3
19.1
22.8
25.6
31
34.4
38.1
45.5
51
62

16.7
20.3
23.8
28
33.2
36.5
40.3
47.4
56
67

2.02
2.36
2.97
3.4
4.13
4.38
4.99
5.93
6.8
8.25

33
29
29
31
36
39
38
36
35
40

135
136
125
112
130
119
98
155
135
87

200

155

74

82

7.42 12

269

191

73

80

9.23 18

253

203

73

80

9.81 21

248

240

169

89

100

8.13 15

263

223

86

96

10.8 24

238

241

87

96

11.6 28

229

040 30 23.1
050
28
060
34.1
070
38.8
080
46.3
090
50
100
56
120
68
140
77
160
92
200
116
240
138

Legend:
LWT
CAP kW
COMP kW
UNIT kW
COND l/s
COND kPa
PRES kPa

Leaving water temperature


Net nominal heating capacity = gross heating capacity minus the capacity
corresponding to the available pressure (flow x pressure/0.3).
Compressor power input
Unit power input, (compressors, fans, control circuit and pumps) minus the
capacity corresponding to the available pressure (flow x pressure/0.3).
Condenser water flow rate
Condenser pressure drop
Available pressure at the unit outlet (unit with single-pump hydronic
module)
Capacity based on standard EUROVENT conditions

Full load correction factors for Eurovent laboratory test:


Net heating capacity
1.000
Energy efficiency ratio
1.000
Heat exchanger pressure drop
1.000
Application data:
Standard units
Refrigerant: R-407C
Condenser temperature rise: 5 K
Condenser fluid: water
Fouling factor: 0.44 x 10-4 (m2 K)/W
Performances in accordance with EN 255.

Heating capacity at low outdoor temperature


The published heating capacities are instantaneous capacities. They do not take account
of the decrease of the heating capacity, resulting from the formation of frost on the coil and
the effect of the defrost cycles.
The integrated heating capacity takes these effects into account. They depend on the temperature and the relative humidity (rh) of the outdoor air.
Correction factor to obtain integrated heating capacities
Leaving water temp. C

30
35
40
45
50

Outdoor temperature C (87% rh)


-10

-5

10

0.88
0.87
0.88
0.89
0.91

0.85
0.85
0.85
0.86
0.89

0.87
0.87
0.87
0.88
0.91

1
1
1
1
1

1
1
1
1
1

Note:
The Carrier electronic selection program permits calculating the integrated heating capacity as a function of the actual humidity conditions at the installation site. Contact Carrier
for your personalised heat pump selection.

Heating capacities, dual pump


LWT

30RH

Entering air temperature, C


-10
CAP

C kW

-5
COMP UNIT

PRES CAP

0
COMP UNIT

COND

PRES CAP

7
COMP UNIT

COND

PRES CAP

10
COMP UNIT

COND

PRES CAP

COMP UNIT

COND

PRES

kW

l/s

kPa kPa

kW

kW

kW

l/s

kPa kPa

kW

kW

kW

l/s

kPa kPa

kW

kW

kW

l/s

kPa kPa

kW

kW

kW

l/s

kPa kPa

040 30 24.4 8.79


050
29.2 11.3
060
35.3 13.4
070
40
14.7
080
47.4 18
090
51
20.1
100
57
22.2
120
69
26.8
140
79
29.5
160
94
36
200
116 46.5
240
138 60

11.9
14.3
16.2
18.8
21.8
23.6
25.5
31.1
36.3
42.3
56
72

1.09
1.32
1.62
1.85
2.22
2.41
2.71
3.25
3.71
4.44
5.48
6.59

10
9
9
9
10
13
12
12
11
13
7
10

207
208
208
207
205
202
200
196
195
192
282
275

27.5
33
39.9
45.3
54
58
65
79
89
107
137
157

8.85
11.4
13.5
14.9
18.1
20.2
22.4
27
29.7
36.2
47.6
60

11.9
14.2
16.1
18.7
21.7
23.5
25.5
31
36.2
42.3
56
72

1.24
1.51
1.85
2.12
2.53
2.75
3.09
3.71
4.23
5.07
6.57
7.52

13
12
11
12
13
16
16
15
15
16
10
13

205
206
206
204
201
196
194
192
191
186
275
268

32.4
39
47.3
54
64
69
77
94
106
127
162
186

9.22
11.8
14
15.5
18.9
21.1
23.3
28.1
31
37.7
49.3
63

12.1
14.5
16.5
19.1
22.2
24.1
26.1
31.7
37.1
43.4
57
73

1.48
1.81
2.21
2.53
3.03
3.29
3.69
4.43
5.06
6.06
7.8
8.98

18
17
16
17
19
23
22
21
20
22
13
17

200
201
200
197
192
186
182
185
183
175
265
255

43.3
55
64
71
86
97
105
126
141
171
202
245

10.1
12.5
14.8
16.9
19.9
22.7
24.9
29.6
33.7
39.7
47.2
57

12.8
14.9
16.9
20.2
22.9
25.5
27.6
32.7
39.3
45.1
54
67

2.01
2.6
3.01
3.36
4.09
4.61
5.02
6.02
6.72
8.17
9.74
11.9

33
35
29
30
35
43
38
37
34
39
20
29

185
181
182
178
165
149
146
162
160
142
248
226

46.8
59
68
76
92
104
113
135
152
184
214
263

10.3
12.7
15
17.1
20.1
23
25.3
30
34.3
40.3
47.6
58

12.9
15
17
20.4
23.2
25.9
28
33.1
39.8
45.7
54
67

2.18
2.77
3.23
3.64
4.39
4.95
5.41
6.46
7.27
8.78
10.3
12.7

39
39
34
36
40
49
44
42
39
44
23
33

179
175
176
170
155
138
133
155
150
130
243
216

040 35 24.1 9.67


050
28.8 12.4
060
34.8 14.7
070
39.4 16.3
080
46.7 19.8
090
50
22.1
100
56
24.4
120
68
29.4
140
78
32.6
160
92
39.6
200
114 51
240
136 65

12.8
15.4
17.5
20.3
23.6
25.6
27.7
33.7
39.4
46
61
77

1.07
1.3
1.6
1.83
2.19
2.37
2.67
3.2
3.65
4.37
5.4
6.49

9
9
8
9
10
12
12
11
11
12
7
10

208
208
209
208
205
202
201
196
196
193
283
276

27.2
32.6
39.4
44.7
53
57
64
78
88
105
136
155

9.74
12.5
14.8
16.4
19.9
22.2
24.5
29.6
32.8
39.9
53
66

12.8
15.4
17.4
20.3
23.6
25.5
27.7
33.6
39.3
45.9
61
77

1.22
1.49
1.83
2.09
2.5
2.71
3.05
3.66
4.18
5
6.49
7.42

12
11
11
12
13
16
15
15
14
16
10
12

205
206
206
204
201
197
195
192
192
187
276
269

32.1
38.6
46.8
53
63
68
77
93
105
125
161
184

10.1
12.9
15.3
17
20.7
23
25.4
30.7
34
41.4
54
68

13
15.6
17.8
20.7
24.1
26.1
28.3
34.4
40.2
47
62
78

1.46
1.79
2.19
2.5
2.99
3.25
3.65
4.38
5
5.99
7.72
8.88

17
16
16
17
19
22
21
21
20
22
13
17

200
201
200
198
192
187
183
185
184
176
266
256

42
53
62
70
83
93
102
123
138
166
198
238

11.2
13.9
16.5
18.7
22.1
25.1
27.6
32.9
37.3
44.2
52
63

13.9
16.3
18.6
22
25.2
27.9
30.3
36.1
42.9
49.6
59
73

1.95
2.47
2.92
3.31
3.96
4.42
4.87
5.85
6.61
7.92
9.54
11.5

31
31
28
29
33
40
36
35
33
37
20
28

187
185
185
180
169
156
151
165
162
146
250
230

45.5
56
66
75
89
100
110
132
150
178
209
256

11.3
14.1
16.7
18.9
22.4
25.5
28
33.4
37.9
44.8
53
64

14
16.5
18.7
22.2
25.4
28.3
30.7
36.5
43.4
50
59
73

2.12
2.64
3.14
3.58
4.26
4.75
5.26
6.29
7.16
8.53
10.1
12.4

37
36
32
34
38
45
42
40
38
42
22
32

181
179
179
172
160
145
138
158
152
135
245
220

040 40 23.5 10.7


050
28.1 13.7
060
33.9 16.2
070
38.4 18.1
080
45.5 21.9
090
49.2 24.4
100
55
26.9
120
67
32.5
140
76
36.2
160
90
43.9
200
112 57
240
132 72

13.9
16.7
19
22.2
25.8
28
30.3
36.8
43
50
67
84

1.04
1.27
1.56
1.78
2.13
2.31
2.6
3.11
3.55
4.25
5.31
6.31

9
8
8
8
9
12
11
11
11
12
7
9

208
209
209
208
206
203
202
197
196
194
283
277

26.6
31.9
38.6
43.7
52
56
63
76
86
103
134
151

10.8
13.8
16.3
18.2
22.1
24.6
27.1
32.6
36.4
44.1
58
72

13.9
16.7
19
22.1
25.7
27.9
30.3
36.7
43
50
67
83

1.19
1.46
1.78
2.04
2.44
2.65
2.98
3.57
4.08
4.88
6.4
7.24

12
11
10
11
12
15
14
14
14
15
9
12

206
206
207
205
202
198
196
193
192
188
276
270

31.5
37.9
45.9
52
62
67
75
91
103
123
159
181

11.1
14.2
16.9
18.8
22.8
25.4
28
33.7
37.7
45.6
60
74

14.1
17
19.3
22.5
26.2
28.5
30.9
37.4
43.8
51
68
85

1.43
1.75
2.15
2.45
2.93
3.18
3.58
4.29
4.9
5.87
7.63
8.71

17
16
15
16
18
21
20
20
19
21
13
16

201
202
201
199
193
188
185
186
185
178
267
258

41.1
50
60
68
81
89
100
120
136
162
194
232

12.3
15.5
18.3
20.7
24.7
27.8
30.7
36.6
41.3
49.4
58
70

15
17.9
20.4
24
27.8
30.6
33.3
39.8
47
55
65
80

1.9
2.35
2.85
3.25
3.88
4.26
4.76
5.7
6.5
7.75
9.38
11.2

30
28
26
28
31
37
35
34
32
35
19
26

189
188
186
181
171
161
154
167
164
150
252
233

44.5
54
65
74
88
96
108
129
147
175
206
250

12.5
15.7
18.5
20.9
25
28.2
31
37.1
41.9
49.9
59
71

15.1
18
20.6
24.2
28
31
33.7
40.2
47.4
55
65
80

2.07
2.52
3.07
3.52
4.18
4.59
5.14
6.15
7.05
8.36
9.96
12.1

35
33
31
33
37
43
40
38
37
40
21
30

183
183
181
174
162
150
142
160
154
138
246
224

040 45 050
060
070
080
090
100
120
140
160
200
240
-

25.7
30.9
37.3
42.3
50
54
61
73
83
99
132
146

12
15.3
18.1
20.3
24.5
27.3
30.1
36.1
40.5
49.1
65
79

15.1
18.2
20.8
24.2
28.2
30.7
33.3
40.3
47.2
55
74
91

1.15
1.41
1.72
1.97
2.36
2.56
2.87
3.45
3.93
4.71
6.3
6.99

11
10
10
10
12
14
14
13
13
14
9
11

206
207
207
206
203
200
198
194
194
190
277
272

30.6
36.9
44.6
51
60
65
73
88
100
119
157
176

12.3
15.7
18.6
20.9
25.3
28.1
30.9
37.2
41.8
51
66
81

15.3
18.5
21.1
24.6
28.7
31.2
33.9
41
48.1
56
75
92

1.39
1.7
2.08
2.38
2.85
3.09
3.48
4.17
4.76
5.7
7.53
8.46

16
15
14
15
17
20
19
19
18
20
13
16

202
203
202
200
195
190
187
187
186
180
268
260

40.4
48.3
59
67
80
87
98
117
134
160
192
227

13.7
17.1
20.3
22.9
27.5
30.8
34
40.7
45.8
55
65
78

16.4
19.6
22.5
26.2
30.6
33.6
36.7
43.9
51
60
72
87

1.87
2.26
2.79
3.19
3.83
4.13
4.66
5.58
6.38
7.66
9.28
11

29
26
25
27
31
35
33
32
31
35
19
25

190
190
188
183
172
164
157
169
165
151
253
236

43.9
52
64
73
87
94
106
126
145
173
204
245

13.8
17.3
20.6
23.2
27.8
31.2
34.4
41.1
46.3
56
65
79

16.5
19.7
22.6
26.4
30.9
34
37.1
44.3
52
61
72
88

2.04
2.43
3.01
3.46
4.13
4.47
5.05
6.03
6.93
8.27
9.86
11.8

34
30
29
32
36
40
39
37
36
40
21
29

184
186
182
175
164
154
145
162
157
140
247
226

040 50 050
060
070
080
090
100
120
140
160
-

29.5
35.5
43
48.8
58
63
70
85
97
115

13.7
17.4
20.6
23.3
28.1
31.1
34.3
41.2
46.5
56

16.7
20.2
23.1
27
31.6
34.3
37.3
45.1
53
62

1.34
1.63
2
2.29
2.74
2.97
3.34
4.01
4.58
5.48

15
14
13
14
16
19
18
17
17
19

203
204
203
201
197
192
190
189
188
182

40.1
46.9
58
66
80
85
96
115
131
160

15.1
18.9
22.5
25.3
30.7
34
37.7
45.1
51
61

17.9
21.4
24.7
28.7
33.8
36.9
40.3
48.4
56
67

1.86
2.19
2.75
3.13
3.82
4.05
4.6
5.49
6.25
7.65

28
25
25
26
30
34
33
31
30
34

190
192
189
184
173
167
159
171
167
151

43.5
50
63
72
87
92
104
125
142
173

15.3
19.1
22.8
25.6
31
34.4
38.1
45.5
51
62

18
21.5
24.9
28.9
34
37.2
40.7
48.7
57
67

2.02
2.36
2.97
3.4
4.13
4.38
4.99
5.93
6.8
8.25

33
29
29
31
36
39
38
36
35
40

185
188
183
177
164
157
147
164
159
140

200

155

74

82

7.42 12

269

191

73

80

9.23 18

253

203

73

80

9.81 21

248

240

169

89

100

8.13 15

263

223

86

96

10.8 24

238

241

87

96

11.6 28

229

Legend:
LWT
CAP kW
COMP kW
UNIT kW
COND l/s
COND kPa
PRES kPa

kW

COND

Leaving water temperature


Net nominal heating capacity = gross heating capacity minus the capacity
corresponding to the available pressure (flow x pressure/0.3).
Compressor power input
Unit power input, (compressors, fans, control circuit and pumps) minus the
capacity corresponding to the available pressure (flow x pressure/0.3).
Condenser water flow rate
Condenser pressure drop
Available pressure at the unit outlet (unit with single-pump hydronic
module)
Capacity based on standard EUROVENT conditions

Full load correction factors for Eurovent laboratory test:


Net heating capacity
1.000
Energy efficiency ratio
1.000
Heat exchanger pressure drop
1.000
Application data:
Standard units
Refrigerant: R-407C
Condenser temperature rise: 5 K
Condenser fluid: water
Fouling factor: 0.44 x 10-4 (m2 K)/W
Performances in accordance with EN 255.

Heating capacity at low outdoor temperature


The published heating capacities are instantaneous capacities. They do not take account
of the decrease of the heating capacity, resulting from the formation of frost on the coil and
the effect of the defrost cycles.
The integrated heating capacity takes these effects into account. They depend on the temperature and the relative humidity (rh) of the outdoor air.
Correction factor to obtain integrated heating capacities
Leaving water temp. C

30
35
40
45
50

Outdoor temperature C (87% rh)


-10

-5

10

0.88
0.87
0.88
0.89
0.91

0.85
0.85
0.85
0.86
0.89

0.87
0.87
0.87
0.88
0.91

1
1
1
1
1

1
1
1
1
1

Note:
The Carrier electronic selection program permits calculating the integrated heating capacity as a function of the actual humidity conditions at the installation site. Contact Carrier
for your personalised heat pump selection.
For 200 and 240 units, the capacities calculated with double pump are the same than the
capacities calculated with single pump

Cooling capacities, single pump


Condenser entering air temperature, C
LWT

30RH

25

30

CAP COMP UNIT

C kW kW

COOL

35

PRES CAP COMP UNIT

COOL

40

PRES CAP COMP UNIT

COOL

45

PRES CAP COMP UNIT

COOL

PRES CAP COMP UNIT

COOL

PRES

kW

l/s

kPa kPa

kW kW

kW

l/s

kPa kPa

kW kW

kW

l/s

kPa kPa

kW kW

kW

l/s

kPa kPa

kW kW

kW

l/s

kPa kPa

040 5
050
060
070
080
090
100
120
140
160
200
240

40
46.8
57
69
76
87
97
114
138
151
189
223

10.5
13.2
16
18.5
23
23.7
26.5
32
36.9
45.9
54
65

11.9
14.4
17.1
20.9
25.2
25.7
28.5
33.8
41.5
51
61
75

1.91
2.23
2.7
3.28
3.58
4.15
4.62
5.41
6.57
7.16
8.95
10.6

30
26
24
29
27
35
33
30
33
31
17
24

140
140
134
117
154
130
116
171
143
129
256
240

37.7
44.2
54
66
71
83
92
108
131
143
179
211

11.6
14.7
17.7
20.3
25.4
26.2
29.2
35.4
40.6
51
59
72

13
16
18.8
22.7
27.6
28.3
31.2
37.2
45.1
55
67
82

1.81
2.11
2.56
3.12
3.39
3.92
4.37
5.12
6.23
6.77
8.47
9.99

27
23
21
26
24
32
30
27
30
28
16
21

143
144
139
124
162
140
128
179
154
142
260
246

35.6
41.6
51
62
67
78
87
102
124
134
168
199

12.7
16.3
19.5
22.3
27.9
29
32.2
39
44.6
56
65
79

14.2
17.6
20.6
24.7
30.2
31
34.2
40.9
49.1
60
73
90

1.71
1.99
2.41
2.95
3.19
3.7
4.12
4.83
5.9
6.38
7.99
9.42

24
20
19
23
21
28
27
25
27
25
14
19

147
148
144
130
169
150
139
186
164
155
264
251

33.4
39
47.6
58
63
73
82
96
117
126
158
187

14
17.9
21.4
24.4
30.7
31.9
35.4
42.8
48.9
61
72
87

15.5
19.3
22.6
26.9
33
33.9
37.3
44.8
53
66
80
98

1.61
1.86
2.27
2.78
2.99
3.47
3.88
4.54
5.56
5.98
7.52
8.85

21
18
17
21
19
25
24
22
24
22
13
17

150
151
148
136
176
159
149
193
174
167
268
257

31.3
36.3
44.6
55
59
69
77
90
110
118
148
174

15.4
19.7
23.4
26.7
33.6
35.1
38.8
46.8
53
67
79
96

16.9
21.1
24.6
29.2
35.9
37.1
40.7
48.9
58
72
87
106

1.51
1.74
2.13
2.6
2.79
3.25
3.63
4.25
5.21
5.58
7.05
8.27

19
16
15
18
16
22
21
19
21
19
11
15

153
154
151
141
183
167
158
199
183
177
271
262

040 6
050
060
070
080
090
100
120
140
160
200
240

41.4
48.3
59
71
78
90
100
118
143
155
196
231

10.6
13.4
16.2
18.7
23.3
24
26.8
32.4
37.4
46.5
55
66

12
14.6
17.3
21.1
25.5
26.1
28.9
34.2
42
51
62
75

1.98
2.3
2.79
3.39
3.7
4.29
4.77
5.58
6.79
7.39
9.26
10.9

32
27
25
31
29
37
35
32
35
32
18
25

137
138
131
113
150
123
108
166
136
121
253
237

39.1
45.7
56
68
74
85
95
111
136
147
185
218

11.7
14.9
17.9
20.5
25.7
26.6
29.6
35.8
41.1
51
60
73

13.1
16.1
19
23
27.9
28.6
31.6
37.6
45.6
56
68
83

1.87
2.18
2.64
3.22
3.49
4.05
4.52
5.29
6.45
6.99
8.76
10.3

29
24
23
28
25
34
31
29
31
29
17
23

141
142
136
120
158
134
121
174
147
135
257
243

36.9
43
52
64
69
81
90
105
129
139
174
206

12.9
16.4
19.7
22.5
28.3
29.3
32.6
39.4
45.1
57
66
80

14.3
17.7
20.8
25
30.5
31.3
34.5
41.3
49.6
61
74
90

1.77
2.06
2.5
3.05
3.29
3.82
4.26
4.99
6.1
6.58
8.27
9.74

26
22
20
25
23
30
28
26
28
26
15
20

145
146
141
126
166
144
132
182
158
148
262
248

34.7
40.4
49.3
60
65
76
85
99
121
130
164
193

14.2
18.1
21.6
24.7
31
32.3
35.8
43.2
49.4
62
73
88

15.6
19.4
22.8
27.1
33.3
34.3
37.7
45.2
54
66
81
99

1.66
1.93
2.35
2.87
3.09
3.6
4.01
4.7
5.75
6.18
7.79
9.15

23
19
18
22
20
27
25
23
25
23
13
18

148
149
145
133
173
154
143
189
168
161
266
254

32.5
37.7
46.2
57
61
71
79
93
114
122
154
181

15.5
19.9
23.6
27
34
35.4
39.2
47.3
54
68
80
97

17
21.2
24.9
29.4
36.3
37.4
41.1
49.3
58
72
88
107

1.56
1.81
2.2
2.7
2.89
3.37
3.76
4.4
5.39
5.77
7.31
8.56

20
17
16
20
17
24
22
21
23
21
12
16

151
152
149
138
180
163
153
196
178
172
269
259

040 7
050
060
070
080
090
100
120
140
160
200
240

42.8
49.8
61
74
80
93
104
121
147
160
202
238

10.7
13.6
16.4
18.9
23.6
24.3
27.1
32.8
37.8
47.1
55
67

12.1
14.8
17.5
21.3
25.8
26.4
29.3
34.6
42.5
52
62
76

2.05
2.38
2.88
3.5
3.81
4.42
4.93
5.76
7.01
7.62
9.57
11.3

34
29
27
33
30
40
37
34
37
34
20
27

134
135
128
108
145
117
101
160
128
112
250
233

40.5
47.1
57
70
76
88
98
115
140
152
191
226

11.8
15.1
18.1
20.8
26
26.9
29.9
36.2
41.5
52
61
74

13.2
16.3
19.2
23.2
28.2
28.9
32
38
46.1
57
68
83

1.94
2.25
2.73
3.33
3.6
4.19
4.67
5.46
6.66
7.21
9.06
10.7

31
26
24
30
27
36
33
31
33
31
18
24

139
139
134
115
153
128
114
169
140
128
255
239

38.2
44.5
54
66
72
83
93
109
133
143
180
213

13
16.6
19.9
22.8
28.6
29.7
33
39.8
45.6
57
67
81

14.5
17.9
21
25.2
30.8
31.7
34.9
41.7
50
62
75
91

1.83
2.12
2.58
3.15
3.4
3.95
4.41
5.15
6.3
6.79
8.55
10.1

27
23
22
27
24
32
30
28
30
28
16
22

143
144
139
122
162
139
126
178
152
142
259
245

35.9
41.8
51
62
67
78
87
102
125
135
170
200

14.3
18.3
21.9
24.9
31.4
32.6
36.2
43.7
49.9
63
74
89

15.8
19.6
23
27.4
33.6
34.6
38.1
45.6
54
67
81
99

1.72
2
2.43
2.97
3.19
3.72
4.15
4.85
5.94
6.38
8.06
9.45

24
21
19
24
21
29
27
25
27
25
14
19

146
147
143
129
169
149
137
186
163
155
263
251

33.7
39.1
47.7
59
63
74
82
96
118
126
159
187

15.7
20
23.9
27.2
34.3
35.7
39.6
47.8
54
69
81
98

17.2
21.4
25.1
29.7
36.6
37.7
41.5
49.8
59
73
89
108

1.62
1.87
2.28
2.79
2.98
3.49
3.89
4.55
5.57
5.96
7.57
8.85

22
18
17
21
19
25
24
22
24
22
13
17

149
151
147
135
177
158
148
193
173
167
267
257

040 8
050
060
070
080
090
100
120
140
160
200
240

44.2
51
62
76
83
96
107
125
152
165
209
246

10.9
13.8
16.6
19.1
23.9
24.6
27.4
33.2
38.2
47.7
56
68

12.2
15
17.6
21.6
26.1
26.8
29.7
35
43.1
53
63
77

2.12
2.45
2.97
3.61
3.92
4.56
5.09
5.94
7.23
7.84
9.88
11.6

37
31
29
35
32
42
39
36
39
36
21
28

131
132
125
103
140
110
92
155
120
104
247
229

41.8
48.6
59
72
78
91
101
119
145
156
198
233

12
15.2
18.3
21
26.3
27.2
30.3
36.6
42
53
62
75

13.4
16.5
19.4
23.4
28.5
29.3
32.4
38.4
46.7
57
69
84

2
2.32
2.81
3.43
3.71
4.32
4.82
5.63
6.87
7.42
9.35
11

33
28
26
32
29
38
35
33
35
33
19
25

136
137
131
111
149
122
106
164
133
120
252
236

39.5
45.9
56
68
74
86
96
112
137
147
187
220

13.2
16.8
20.1
23
28.9
30
33.3
40.3
46.1
58
68
82

14.6
18.1
21.2
25.4
31.1
32
35.4
42.1
51
62
75
92

1.89
2.19
2.66
3.25
3.5
4.08
4.55
5.32
6.5
7
8.84
10.4

29
25
23
28
26
34
32
29
32
29
17
23

140
141
136
118
158
133
119
173
145
135
257
242

37.1
43.2
53
64
69
81
90
106
129
139
176
206

14.5
18.5
22.1
25.2
31.7
32.9
36.5
44.2
50
63
75
90

15.9
19.8
23.2
27.6
34
34.9
38.5
46
55
68
82
100

1.78
2.06
2.5
3.07
3.29
3.84
4.29
5.01
6.13
6.58
8.33
9.76

26
22
20
25
23
31
29
26
29
26
15
20

144
146
141
126
166
143
131
182
157
149
261
248

34.9
40.5
49.3
61
65
76
85
99
121
130
165
193

15.8
20.2
24.1
27.5
34.7
36
40
48.3
55
69
82
99

17.3
21.6
25.3
29.9
37
38
41.9
50
60
74
90
109

1.67
1.94
2.35
2.88
3.08
3.61
4.02
4.7
5.75
6.16
7.83
9.14

23
19
18
22
20
27
25
23
26
23
14
18

148
149
145
132
173
153
143
189
168
162
265
254

040 10 47.1
050
54
060
66
070
80
080
87
090
102
100
113
120
132
140
161
160
174
200
222
240
260

11.1
14.1
17
19.6
24.5
25.3
28.1
33.9
39.1
48.9
58
69

12.5
15.3
18
22.1
26.7
27.6
30.6
35.8
44.2
54
64
78

2.25
2.59
3.15
3.83
4.15
4.84
5.4
6.29
7.67
8.3
10.5
12.3

42
34
32
39
36
47
44
40
43
40
23
31

125
127
117
92
129
95
75
143
102
85
241
221

44.6
52
63
77
83
96
107
126
153
165
210
247

12.3
15.6
18.7
21.5
26.9
27.9
31
37.5
42.9
54
63
76

13.6
16.8
19.8
23.9
29.2
30
33.3
39.3
47.8
59
70
86

2.13
2.46
2.98
3.65
3.93
4.59
5.12
5.97
7.29
7.86
9.94
11.7

37
31
29
36
32
43
40
36
39
36
21
28

131
132
124
101
139
108
91
154
117
103
246
229

42.1
48.8
59
73
78
91
102
119
145
156
199
233

13.5
17.2
20.6
23.5
29.6
30.6
34.1
41.2
47
59
70
84

14.9
18.4
21.7
26
31.8
32.7
36.2
43
52
64
77
93

2.01
2.33
2.82
3.45
3.71
4.34
4.84
5.64
6.91
7.42
9.4
11

33
28
26
32
29
38
36
33
36
33
19
25

136
137
130
110
149
121
105
164
131
120
251
235

39.6
46
56
68
74
86
96
112
137
147
187
219

14.8
18.8
22.6
25.7
32.4
33.6
37.3
45.1
51
65
76
92

16.2
20.1
23.6
28.1
34.6
35.6
39.3
46.9
56
69
84
102

1.9
2.2
2.66
3.26
3.49
4.09
4.56
5.32
6.52
6.98
8.87
10.4

30
25
23
28
25
34
32
29
32
29
17
23

140
141
136
118
158
132
119
173
145
135
256
242

37.2
43.2
52
64
81
90
105
129
176
205

16.1
20.6
24.6
28.1
36.7
40.8
49.3
56
84
101

17.6
21.9
25.8
30.5
38.7
42.7
51
61
91
111

1.78
2.06
2.5
3.06
3.85
4.28
5
6.12
8.35
9.71

26
22
20
25
31
28
26
29
15
20

144
146
141
126
143
132
182
157
261
249

Legend:
LWT
CAP kW

Leaving water temperature


Net cooling capacity = gross cooling capacity plus the capacity corresponding
to the available pressure (flow x pressure/0.3).
COMP kW Compressor power input
UNIT kW
Unit power input (compressors, fans, control circuit and pumps) minus the
capacity corresponding to the available pressure (flow x pressure/0.3).
COOL l/s Evaporator water flow rate
COOL kPa Evaporator pressure drop
PRES kPa Available pressure at the unit outlet (unit with single-pump hydronic module)

Full load correction factors for Eurovent laboratory test:


Net cooling capacity
1.000
Energy efficiency ratio
1.000
Evaporator pressure drop
1.000
Application data:
Standard units
Refrigerant: R-407C
Evaporator temperature rise: 5 K
Evaporator fluid: chilled water
Fouling factor: 0.44 x 10-4 (m2 K)/W

Capacity based on standard EUROVENT conditions


Performances in accordance with EN 12055.

Cooling capacities, dual pump


Condenser entering air temperature
LWT

30RH

25

30

CAP COMP UNIT

C kW kW

COOL

35

PRES CAP COMP UNIT

COOL

40

PRES CAP COMP UNIT

COOL

45

PRES CAP COMP UNIT

COOL

PRES CAP COMP UNIT

COOL

PRES

kW

l/s

kPa kPa

kW kW

kW

l/s

kPa kPa

kW kW

kW

l/s

kPa kPa

kW kW

kW

l/s

kPa kPa

kW kW

kW

l/s

kPa kPa

040 5
050
060
070
080
090
100
120
140
160
200
240

38.8
45.7
56
68
75
87
97
113
137
150
189
223

10.5
13.2
16
18.5
23
23.7
26.5
32
36.9
45.9
54
65

13.2
15.7
18.2
21.8
26.1
26.5
29.1
35.3
42.6
51
61
75

1.91
2.23
2.7
3.28
3.58
4.15
4.62
5.41
6.57
7.16
8.95
10.6

30
26
24
29
27
35
33
30
33
31
17
24

188
191
190
180
179
164
158
172
162
159
256
240

36.6
43.1
53
65
70
82
91
107
130
142
179
211

11.6
14.7
17.7
20.3
25.4
26.2
29.2
35.4
40.6
51
59
72

14.3
17.2
19.9
23.7
28.6
29.1
31.9
38.8
46.3
56
67
82

1.81
2.11
2.56
3.12
3.39
3.92
4.37
5.12
6.23
6.77
8.47
9.99

27
23
21
26
24
32
30
27
30
28
16
21

191
194
193
184
184
170
166
176
168
165
260
246

34.4
40.5
49.7
61
66
77
86
100
123
133
168
199

12.7
16.3
19.5
22.3
27.9
29
32.2
39
44.6
56
65
79

15.5
18.9
21.8
25.7
31.2
31.9
35
42.5
50
61
73
90

1.71
1.99
2.41
2.95
3.19
3.7
4.12
4.83
5.9
6.38
7.99
9.42

24
20
19
23
21
28
27
25
27
25
14
19

194
197
196
188
188
176
172
180
172
171
264
251

32.3
37.8
46.6
57
62
72
81
94
116
125
158
187

14
17.9
21.4
24.4
30.7
31.9
35.4
42.8
48.9
61
72
87

16.9
20.6
23.8
28
34.1
34.9
38.2
46.4
55
67
80
98

1.61
1.86
2.27
2.78
2.99
3.47
3.88
4.54
5.56
5.98
7.52
8.85

21
18
17
21
19
25
24
22
24
22
13
17

197
200
199
192
192
182
178
183
177
176
268
256

30.1
35.2
43.5
54
58
68
76
88
109
117
148
174

15.4
19.7
23.4
26.7
33.6
35.1
38.8
46.8
53
67
79
96

18.3
22.4
25.9
30.3
37.1
38.1
41.6
51
59
73
87
106

1.51
1.74
2.13
2.6
2.79
3.25
3.63
4.25
5.21
5.58
7.05
8.27

19
16
15
18
16
22
21
19
21
19
11
15

199
202
201
196
196
187
184
187
181
181
271
262

040 6
050
060
070
080
090
100
120
140
160
200
240

40.3
47.3
58
71
77
90
100
116
142
155
196
231

10.6
13.4
16.2
18.7
23.3
24
26.8
32.4
37.4
46.5
55
66

13.3
15.8
18.3
22
26.4
26.8
29.4
35.6
43
52
62
75

1.98
2.3
2.79
3.39
3.7
4.29
4.77
5.58
6.79
7.39
9.26
10.9

32
27
25
31
29
37
35
32
35
32
18
25

186
189
188
177
176
160
154
169
159
156
253
237

38
44.6
55
67
73
85
95
110
135
146
185
218

11.7
14.9
17.9
20.5
25.7
26.6
29.6
35.8
41.1
51
60
73

14.4
17.4
20.1
23.9
28.9
29.4
32.3
39.1
46.7
57
68
83

1.87
2.18
2.64
3.22
3.49
4.05
4.52
5.29
6.45
6.99
8.76
10.3

29
24
23
28
25
34
31
29
31
29
17
23

190
192
191
182
181
166
161
174
164
162
257
243

35.7
41.9
51
63
69
80
89
104
128
138
174
206

12.9
16.4
19.7
22.5
28.3
29.3
32.6
39.4
45.1
57
66
80

15.7
19
22
25.9
31.5
32.2
35.3
42.8
51
62
74
90

1.77
2.06
2.5
3.05
3.29
3.82
4.26
4.99
6.1
6.58
8.27
9.74

26
22
20
25
23
30
28
26
28
26
15
20

193
195
194
186
186
173
168
178
170
168
262
248

33.5
39.3
48.3
60
64
75
84
98
120
129
164
193

14.2
18.1
21.6
24.7
31
32.3
35.8
43.2
49.4
62
73
88

17
20.7
24
28.2
34.4
35.2
38.5
46.8
55
68
81
99

1.66
1.93
2.35
2.87
3.09
3.6
4.01
4.7
5.75
6.18
7.79
9.15

23
19
18
22
20
27
25
23
25
23
13
18

196
198
197
190
190
179
175
181
174
174
266
254

31.3
36.6
45.1
56
60
70
79
91
112
121
154
181

15.5
19.9
23.6
27
34
35.4
39.2
47.3
54
68
80
97

18.4
22.6
26.1
30.5
37.4
38.4
42
51
60
74
88
107

1.56
1.81
2.2
2.7
2.89
3.37
3.76
4.4
5.39
5.77
7.31
8.56

20
17
16
20
17
24
22
21
23
21
12
16

198
201
200
194
194
184
181
185
179
179
269
259

040 7
050
060
070
080
090
100
120
140
160
200
240

41.7
48.8
60
73
79
92
103
120
147
160
202
238

10.7
13.6
16.4
18.9
23.6
24.3
27.1
32.8
37.8
47.1
55
67

13.4
16
18.5
22.2
26.7
27.1
29.8
36
43.4
52
62
76

2.05
2.38
2.88
3.5
3.81
4.42
4.93
5.76
7.01
7.62
9.57
11.3

34
29
27
33
30
40
37
34
37
34
20
27

184
187
186
174
173
155
149
166
155
152
250
233

39.3
46.1
56
69
75
88
98
114
139
151
191
226

11.8
15.1
18.1
20.8
26
26.9
29.9
36.2
41.5
52
61
74

14.5
17.5
20.3
24.1
29.1
29.7
32.6
39.5
47.2
57
68
83

1.94
2.25
2.73
3.33
3.6
4.19
4.67
5.46
6.66
7.21
9.06
10.7

31
26
24
30
27
36
33
31
33
31
18
24

187
191
189
179
178
163
157
171
161
159
255
239

37
43.4
53
65
71
83
92
107
132
142
180
213

13
16.6
19.9
22.8
28.6
29.7
33
39.8
45.6
57
67
81

15.8
19.2
22.2
26.2
31.8
32.5
35.6
43.2
51
63
75
91

1.83
2.12
2.58
3.15
3.4
3.95
4.41
5.15
6.3
6.79
8.55
10.1

27
23
22
27
24
32
30
28
30
28
16
22

191
194
193
184
183
169
164
175
167
165
259
245

34.7
40.7
49.9
62
66
78
87
101
124
134
170
200

14.3
18.3
21.9
24.9
31.4
32.6
36.2
43.7
49.9
63
74
89

17.1
20.9
24.2
28.4
34.7
35.5
38.9
47.2
56
68
81
99

1.72
2
2.43
2.97
3.19
3.72
4.15
4.85
5.94
6.38
8.06
9.45

24
21
19
24
21
29
27
25
27
25
14
19

194
197
196
188
188
175
171
180
172
171
263
251

32.5
38
46.7
58
62
73
81
94
116
125
159
187

15.7
20
23.9
27.2
34.3
35.7
39.6
47.8
54
69
81
98

18.5
22.7
26.3
30.8
37.7
38.7
42.4
51
60
74
89
108

1.62
1.87
2.28
2.79
2.98
3.49
3.89
4.55
5.57
5.96
7.57
8.85

22
18
17
21
19
25
24
22
24
22
13
17

197
199
199
192
193
181
178
183
177
176
267
256

040 8
050
060
070
080
090
100
120
140
160
200
240

43.1
50
62
75
82
95
106
124
151
164
209
246

10.9
13.8
16.6
19.1
23.9
24.6
27.4
33.2
38.2
47.7
56
68

13.5
16.1
18.7
22.4
26.9
27.4
30.1
36.3
43.8
53
63
77

2.12
2.45
2.97
3.61
3.92
4.56
5.09
5.94
7.23
7.84
9.88
11.6

37
31
29
35
32
42
39
36
39
36
21
28

181
185
183
171
170
151
144
164
151
148
247
229

40.7
47.6
58
71
77
90
101
117
144
156
198
233

12
15.2
18.3
21
26.3
27.2
30.3
36.6
42
53
62
75

14.6
17.7
20.4
24.3
29.4
30
32.9
39.9
47.6
58
69
84

2
2.32
2.81
3.43
3.71
4.32
4.82
5.63
6.87
7.42
9.35
11

33
28
26
32
29
38
35
33
35
33
19
25

185
189
187
176
176
159
152
169
158
155
252
236

38.3
44.8
55
68
73
85
95
111
136
147
187
219

13.2
16.8
20.1
23
28.9
30
33.3
40.3
46.1
58
68
82

15.9
19.3
22.4
26.4
32.1
32.8
36
43.6
52
63
75
92

1.89
2.19
2.66
3.25
3.5
4.08
4.55
5.32
6.5
7
8.84
10.4

29
25
23
28
26
34
32
29
32
29
17
23

189
192
191
181
181
166
160
173
163
162
257
242

36
42.1
52
64
68
80
90
104
128
138
176
206

14.5
18.5
22.1
25.2
31.7
32.9
36.5
44.2
50
63
75
90

17.2
21
24.4
28.6
35
35.8
39.3
47.6
56
69
82
100

1.78
2.06
2.5
3.07
3.29
3.84
4.29
5.01
6.13
6.58
8.33
9.76

26
22
20
25
23
31
29
26
29
26
15
20

192
195
194
186
186
172
168
177
169
168
261
248

33.7
39.3
48.3
60
64
75
84
98
120
129
165
193

15.8
20.2
24.1
27.5
34.7
36
40
48.3
55
69
82
99

18.6
22.8
26.5
31
38.1
39
42.7
52
61
75
90
109

1.67
1.94
2.35
2.88
3.08
3.61
4.02
4.7
5.75
6.16
7.83
9.14

23
19
18
22
20
27
25
23
26
23
14
18

195
198
197
190
191
178
174
181
174
174
265
254

040 10 46
050
53
060
65
070
80
080
87
090
101
100
113
120
131
140
161
160
174
200
222
240
260

11.1
14.1
17
19.6
24.5
25.3
28.1
33.9
39.1
48.9
58
69

13.7
16.5
19
22.8
27.5
28.1
30.8
37
44.7
54
64
78

2.25
2.59
3.15
3.83
4.15
4.84
5.4
6.29
7.67
8.3
10.5
12.3

42
34
32
39
36
47
44
40
43
40
23
31

176
181
179
164
163
142
133
158
143
139
241
221

43.5
51
62
76
82
96
107
125
153
165
210
247

12.3
15.6
18.7
21.5
26.9
27.9
31
37.5
42.9
54
63
76

14.9
18
20.8
24.7
30
30.7
33.6
40.6
48.5
59
70
86

2.13
2.46
2.98
3.65
3.93
4.59
5.12
5.97
7.29
7.86
9.94
11.7

37
31
29
36
32
43
40
36
39
36
21
28

181
185
183
170
170
150
143
163
150
148
246
228

41
47.7
58
72
77
91
101
118
145
156
199
233

13.5
17.2
20.6
23.5
29.6
30.6
34.1
41.2
47
59
70
84

16.1
19.6
22.7
26.8
32.7
33.4
36.7
44.4
53
65
77
93

2.01
2.33
2.82
3.45
3.71
4.34
4.84
5.64
6.91
7.42
9.4
11

33
28
26
32
29
38
36
33
36
33
19
25

185
188
187
176
176
158
152
168
157
155
251
235

38.5
44.9
55
68
73
86
95
111
136
146
187
219

14.8
18.8
22.6
25.7
32.4
33.6
37.3
45.1
51
65
76
92

17.5
21.3
24.8
29
35.6
36.4
40
48.4
57
70
84
102

1.9
2.2
2.66
3.26
3.49
4.09
4.56
5.32
6.52
6.98
8.87
10.4

30
25
23
28
25
34
32
29
32
29
17
23

189
192
191
181
181
165
160
173
163
162
256
242

36
42.1
52
64
80
90
104
128
176
205

16.1
20.6
24.6
28.1
36.7
40.8
49.3
56
84
101

18.9
23.1
26.9
31.5
39.6
43.5
53
62
91
111

1.78
2.06
2.5
3.06
3.85
4.28
5
6.12
8.35
9.71

26
22
20
25
31
28
26
29
15
20

192
195
194
186
172
168
178
169
261
249

Legend:
LWT
CAP kW

Leaving water temperature


Net cooling capacity = gross cooling capacity plus the capacity corresponding to the available pressure (flow x pressure/0.3).
COMP kW Compressor power input
UNIT kW
Unit power input (compressors, fans, control circuit and pumps) minus the
capacity corresponding to the available pressure (flow x pressure/0.3).
COOL l/s Evaporator water flow rate
COOL kPa Evaporator pressure drop
PRES kPa Available pressure at the unit outlet (unit with single-pump hydronic module)

Full load correction factors for Eurovent laboratory test:


Net cooling capacity
1.000
Energy efficiency ratio
1.000
Evaporator pressure drop
1.000
Application data:
Standard units
Refrigerant: R-407C
Evaporator temperature rise: 5 K
Evaporator fluid: chilled water
Fouling factor: 0.44 x 10-4 (m2 K)/W

Capacity based on standard EUROVENT conditions


Performances in accordance with EN 12055.
For sizes 200 and 240 the capacities given for dual-pump units are the same as those for
single-pump units.

Guide specifications
Aquasnap 30RH
Nominal cooling capacity 37-213 kW
Nominal heating capacity 39-227 kW
Reversible air-to-water heat pumps for outdoor installation,
equipped with scroll compressors, low-noise fans, autoadaptive microprocessor control and operating with HFC407C refrigerant which has no effect on the ozone layer.
Part 1 - General
Quality assurance
30RH units comply with requirements of European directives:
- machinery directive 98/37/CE, modified,
- low voltage directive 73/23/EEC, modified.
- electromagnetic compatibility directive 89/336/EEC,
modified
and with the applicable recommendations of European
standards:
- machine safety, electrical equipment in machines,
general regulations: EN 60204-1,
- radiated electromagnetic emissions: EN 50081-1,
- conducted electromagnetic emissions: EN 50081-2,
- electromagnetic immunity EN 50082-2.
30RH units have been designed and tested in a facility with
a quality assurance system certified ISO 9001.
30RH units have been assembled in a facility with an
environment management system certified ISO 14001.
The published performances have been certified by Eurovent and verified by independent laboratories.
All units undergo a run test before shipment.
Part 2 - Products
Equipment
Compressor
Hermetic scroll compressor with only three moving parts,
2-pole electric motor, cooled by suction gas with overload
protection through an internal thermostat and/or thermal
relay. Oil level sight glass and polyolester synthetic oil
charge.

Water heat exchanger


Stainless steel plate heat exchanger with welded copper
connections; from size 30RH 090 upwards the water heat
exchanger has interlaced independent refrigerant circuits.
Closed-cell thermal foam insulation.
Anti-freeze protection during operation by flow switch
(standard on all versions) and during shutdown down to
-20C by electric resistance heater.

Air heat exchanger/fan


One (30RH 040-080) or two (30RH 090-240) vertical coils
with slotted aluminium fins expanded into grooved copper
tubes. Coil protection grille made of steel wire, coated in
polyethylene. Protection against ice build-up by electric
resistance heater on the coil support.
Low-noise axial Carrier Flying Bird fan with 11 blades and
a rotating shroud, made of a composite material. Threephase, two-speed motor (11.5/5.8 r/s or 15.6/7.8 r/s), insulation class F, protection category IP 55, overload protection
by thermal relay. Vertical air flow with protection grille
made of steel wire, coated in polyethylene.

Refrigerant circuit
Each circuit includes: a four-way cycle reversing valve,
liquid line valve, moisture sight glass, two-way expansion
device, receiver/heat exchanger, protecting the compressor
against refrigerant migration, removable suction line screen
filter, high-pressure safety valve, pressure and temperature
sensors, manually reset high pressure switch, and a refrigerant charge of HFC-407C. All components of the refrigerant
circuit are welded for total and lasting leak-tightness.
Control and power circuit control box
The control box is accessible via a hinged door. It includes
a main disconnect switch, fuses and circuit breakers, compressor, fan and water pump contactors, thermal relays,
low-voltage control circuit transformer (24 V control circuit) and the Pro-Dialog control system.
The whole unit is supplied by a single power connection
point (three-phase supply without neutral).
Chassis/cabinet
Chassis and cabinet made of galvanised sheet steel. Painted
in oven-baked polyester powder paint in light grey colour
(RAL 7035). Removable panels with 1/4 turn locks.
Hydronic module
Hydronic module, integrated into the heat pump, including:
removable screen filter, expansion tank, single monocell
centrifugal water pump (dual water pump optional) - threephase motor with internal thermal protection, water flow
switch, safety valve (set to 3 bar for 30RH 040-160 and to 4
bar for 30RH 200-240 units), flow control valve, pressure
gauge and purges. Internal piping made of galvanised steel.
Customer-side Victaulic connections with welding or screw
connection sleeves. Protection against ice build-up down to
-20C by thermal insulation and water pump cycling.
Note: Units without hydronic module (option): internal
water piping protected against frost down to -20C by
electric resistance heater.

Carrier Pro-Dialog Plus control system


Pro-Dialog Plus ensures the following functions:
Control
Entering and leaving water temperature control by PID loop
with compressor run time equalising. The system permanently adjusts the system inertia and ensures complete prevention of excessive compressor cycling. The heat pump
can safely operate with a low system water volume which
often makes the use of a buffer tank unnecessary (see minimum water volume in this document).
Head pressure control by auto-adaptive algorithm (fan
speed).
Water pump control (optional dual pump with automatic
change-over).
Defrost cycle control with auto-adaptation of the parameters.
Control at the second set point (example: unoccupied
room).
Set point reset as a function of the air temperature or the
difference between entering/leaving water temperature.
Automatic change-over of heating/cooling, as a function of
the outdoor temperature with adjustable dead band.
Optional control module with a relay for the control of supplementary electric resistance heaters. Four stages maximum, with start-up of the last stage in case of a heat pump
shutdown as a result of a fault condition.
Safety
The system checks the evolution of the parameters: temperatures, pressures ... and responds to maintain the compressor within the operating range. If despite this one parameter exceeds its limit, an alert message is generated or the
unit is shut down. The following faults cause the refrigerant circuit or the unit to be shut down:
- Low suction pressure
- High discharge pressure
- Low suction temperature
- Low water entering temperature in heating mode
- Compressor, water pump overload
- Reverse compressor rotation
- Temperature sensor and pressure transducer fault
- Board and loss of communication fault
- Customer safety device tripping
- Heat exchanger anti-freeze protection
- More than 50 alert or fault codes to facilitate fault detection

Operator interface
Includes status or fault LEDs, two numerical displays, a
refrigerant system synoptic diagram and a command keyboard.
Immediate display of parameters: entering/leaving water
and ambient air temperatures, compressor suction/discharge pressures and temperatures, set point, operating
temperatures and number of compressor start-ups.
Diagnosis and complete parameter set by selection of one
of the following menus: information, temperatures, pressures, set points, input values, test, configuration, alarms,
alarm history and operating log.
Remote management of the heat pump
Volt-free contact inputs permit:
- Start/stop control
- Selection of cooling or heating mode
- Integration of a customer safety device
- Operation at the second set point* (example room unoccupied)
- Maximum demand limit* (three limit levels from size
30RH 090 onwards)
* One or the other for 30RH 040-080

Outputs are available for:


- Start-up of a boiler relay (shutdown of the heat pump
below a minimum outdoor temperature)
- Signalling of a fault condition for each circuit.
The optional/accessory CCN Clock Board permits:
- Control in master/slave configuration of two heat pumps
operating in parallel.
- Programming of operating time schedules (up to 8
periods per week)
- Programming of operating time schedules for the second
set point (up to 8 periods per week)
- Definition of operating time period with the fan at low
speed (for example during the night)
- Definition of operating time period with demand limit.
- Integration of the heat pump into a building monitoring
system (BMS): serial port RS 485.

Order No. 13422-20, 11 2001. Supersedes: New.


Manufacturer reserves the right to change any product specifications without notice.
The cover photo is solely for illustration purposes, and is not contractually binding.

Manufactured by Carrier SA, Montluel, France.


Printed on Totally Chlorine Free Paper.
Printed in the Netherlands.