A S O N E O F T H E W O R L D S M A J O R A I R C O N D I T I O N I N G C O M PA N I E S

W E D E S I G N , M A N U FA CT U R E A N D S E R V I C E A W I D E R A N G E O F P R O D U CT S FO R A I R C O N D I T I O N I N G M A R K E T S . T H E S E I N C LU D E S P L I T
SY S T E M S A I R C O N D I T I O N E R S , W AT E R A N D A I R C O O L E D C H I L L E R S ,
FA N C O I L U N I T S , PA C K A G E D A I R C O N D I T I O N E R S , M A R I N E A N D
I N D U S T R I A L R E F R I G E R AT I O N SY S T E M S P LU S C O N T R O L S .

42

water systems >

Chiller and heat pump


Indoor units

NEW
ECOFRIO 120-150
NEW OPTIONS FOR ECOFRIO & HVS

43

WATER SYSTEMS

Air cooled chiller


Air to water heat pump
R407C

A COMPLETE RANGE
FROM 6 kW UP TO 156 kW

YCSA 06 to 36

Models YCSA 50 to YCSA 150 : see page 48 / Indoor units : see page 72

Single Scroll Compressor


LWT and RWT Control
Hydro Pack standard
Buffer Tank
Plate heat exchanger
FSC standard (low ambient
operation -10C)

44

Options / Accessories
Unit without pack
Anti corrosion coated condenser fins
Pressostatic LAK (-18C)
(cooling only units)
B.M.S. Communication
Remote control
Condenser grille
Side outlet adapter (models 6 to 18)
Water filter (unit without pack)

R407C

YCSA
6 to 36 kW

Technical features

Performance

Compressor
Air side heat exchanger
Water side heat exchanger

Dimensions & Weight

Electrical features

Cooling capacity cooling only units (1)


Total Input Power (1)
Cooling capacity heat pump units (1)
Heating capacity heat pump units (1)
Total Input Power cooling/heating mode (1) (2)
Total Input Power cooling/heating mode (1) (3)
Capacity steps
Sound power level
Sound pressure level at 10 m
Type
Quantity
Fans quantity
Working Ambient temp. cooling / heating mode (4)
Type
Unit water volume (2)
Pump Type
Available pressure (1) (2)
Pressure drop (1) (3)
Working range water leaving temp. cooling/heating (5)
Water connections
H/W/D
Weight pack / without pack cooling only
Weight pack / without pack heat pumps
Voltage / Phases / Frequency
Running current (max) (2)

kW
kW
kW
kW
kW
kW
%
dB(A)
dB(A)

Litres
kPa
kPa
C
inch
mm
kg
kg
V/ph/hz
A

YCSA / YCSA-H
12 T-TP
18 T-TP
26 T-TP
36 T-TP
12.2 - 12 17.2 - 16.8 25.7 - 25 35.7 - 35.1
4.1 - 4.4
7.8 - 8.2
9.4 - 10.1 14.1 - 14.7
12.2 - 11.9 18.2 - 17.8 25 - 24.6 36.7 - 36.1
12.8 - 13.1 19.6 - 19.9 25.2 - 25.6 33.5 - 34.1
4.4 / 5
8.2 / 7.9
10.1 / 9.9 14.8 / 14.7
4.2 / 4.8
7.8 / 7.6
9.7 / 9.5
14.2 / 14.1
0 - 100%
70
71
71
73
74
78
81
40
41
41
43
44
48
51
Scroll Hermetic
1
1
2
(-18C) -10C ~ 45C / -10C ~ 20C
Plate Heat Exchanger
29
30
30
69
70
118
119
Circulators (3 speeds)
Multistage horizontal pumps
60
54
54
210
180
164
150
10
13
13
40
36
52
56
(-5C) 6C ~ 15C / 30C ~ 50C
1"
1 1/4"
914 / 1 180 / 427
1 270 / 1 430 / 502
1 344 / 1 503 / 904
125 / 105 130 / 110 130 / 110 185 / 150 220 / 185 390 / 330
400 / 340
105 / 115 140 / 120 140 / 120 200 / 165 235 / 200 430 / 370
440 / 380
230 / 1 / 50+E
400 / 3 / 50+N+E
15.9
21.7
7
10.8
16.1
22.9
31.1
6 M-MP
6.1 - 6.1
2.4 - 2.5
5.9 - 5.8
6-6
2.2 / 2.3
2.1 / 2.3

8 M-MP
8.3 - 8.2
3.3 - 3.3
8.3 - 8.2
8.5 - 8.5
3.3 / 3.3
3.3 / 3.2

8 T-TP
8.4 - 8.3
3.2 - 3.3
8.4 - 8.3
8.8 - 8.8
3.3 / 3.3
3.3 / 3.2

(1) at nominal conditions (2) version P with hydro kit (3) version without hydro kit
M single phase T Three phases supply P Pack H Heat pump
(4) -18C with LAK option (5) below 6C with glycol
Nominal conditions: Cooling capacities in kW given for 7C water leaving temperature t 5C and 35C ambient temperature
Heating capacities in kW given for 45C water leaving temperature and 7C ambient temperature

Compatibility table / Codes


Model

YCSA-06-MP

YCSA-08-MP

YCSA-08-TP

YCSA12-TP

YCSA-18-TP

YCSA-26-TP

YCSA-36-TP

Cooling only unit (Pack included)

668520682

668520882

668520884

668521282

668521882

668522582

668523482

Heat pump unit (Pack included)

668620682

668620882

668620884

668621282

668621882

668622682

668623682

Model

YCSA-06-M

YCSA-08-M

YCSA-08-T

YCSA12-T

YCSA-18-T

YCSA-26-T

YCSA-36-T

Cooling only unit (without Pack)

668520680

668520880

668520883

668521280

668521880

668522580

668523480

Heat pump unit (without Pack)

668620680

668620880

668620883

668621280

668621880

668622680

668623680

Options (Factory fitted)

Anti-corrosion coated condenser fins c/o

611080608

611081218

611082626

611083636

Anti-corrosion coated condenser fins h/p

611070608

611071218

611072626

611073636

Copper/copper condenser c/o

611060608

611061218

611062626

611063636

Copper/copper condenser h/p

611050608

611051218

611052626

611053636

LAK -18C for cooling only unit

613112011

Accessories (Supplied loose)


Condenser grille

611090608

611091218

Mechanical flow switch

611992021

Pipe kit side adapters


Water Filter *

611992011
611300100

E-COM-C0601

Remote control

N/A
611300120

611300150

613802011

B.M.S. Communication
*included with unit version P only for unit without pack

611092636

613802021
N/A Not available

45

WATER SYSTEMS

Dimensions and
hydraulic connections
YCSA/H 6 M-MP / 8 M-MP / 8 T-TP
REAR VIEW

SIDE VIEW

42

AIR OUT

914

WATER IN

405

AIR IN

TOP VIEW

42

343

427

15

18

40

1144

15

18

1180

74

100

100

WATER OUT
68

130

AIR IN

210

A- Water inlet 1 Gas F.

B- Water outlet 1 Gas F.

C- Auxiliary lines

YCSA/H 12 T-TP / 18 T-TP

D- Electrical power supply

E- Water refilling 3/8 Gas F.

Only for size 18: Adapters 1 1/4 Gas M. supplied with the unit

REAR VIEW

SIDE VIEW
AIR OUT
43.5

15

415

AIR IN

TOP VIEW

905

1270

502

WATER IN

43.5

B
C
50

1394

18

15

18

1430

100

70

90

WATER OUT
75
D

180

260

AIR IN

A- Water inlet 1 Gas F.

B- Water outlet 1 Gas F.

C- Auxiliary lines

YCSA/H 26 T-TP / 36 T-TP

D- Electrical power supply

E- Water refilling 3/8 Gas F.

Only for size 36: Adapters 1 1/4 - 1 1/2 Gas M. supplied with the unit

SIDE VIEW

FRONT VIEW

AIR OUT

15
1344

REAR VIEW

WATER IN
318

80

383

283

70

WATER OUT

39

50
89

300

292

600

222

826

39

287

904

1503

A- Water inlet 1 1/4 Gas F.


46

B- Water outlet 1 1/4 Gas F.

C- Auxiliary lines

D- Electrical power supply

E- Water refilling 3/8 Gas F.

Space requirements

YCSA
6 to 36 kW

Model YCSA/H 06-08-12-18

Model YCSA/H 26-36

Drawings not at scale


YCSA 06

YCSA 08

YCSA 12

YCSA 18

YCSA 26

YCSA 26P

YCSA 36

YCSA 36P

200

200

300

300

800

1600

800

1600

200

200

300

300

800

800

800

800

500

500

600

600

1000

1000

1000

1000

800

800

800

800

3000

3000

3000

3000

All dimensions in mm
47

WATER SYSTEMS

Air cooled chiller


Air to water heat pump
NEW !

R410A

R407C

A COMPLETE RANGE
FROM 6 kW UP TO 156 kW
YCSA 50 to 100
YCSA 120 & 150

Models YCSA 06 to YCSA 36 : see page 44 / Indoor units : see page 72

YCSA 50 to 100
2 Scroll Compressors
LWT & RWT Control
Hydro Pack standard
Buffer Tank
Plate heat exchanger
FSC standard (low ambient operation -10C)
Condenser protection grille
YCSA 120 to 150
R410A as refrigerant
4 Scroll compressors
High efficiency at full and partial load
Hydro Pack standard
LWT & RWT control
Standard low ambient operation (-18C)
Reduced noise levels
1/4 turn lock for easy access

48

Options / Accessories
Unit without pack
Anti corrosion condenser fins
Pressostatic LAK (-18C)
(cooling only units)
B.M.S. Communication
Remote control
Remote terminal
Water filter (unit without pack)
Low noise version
NEW !
Dual pump version

R407C

YCSA

YCSA

R410A

49 to 96 kW

119 to 156 kW

Technical features

Performance

Compressor
Air side heat exchanger
Water side heat exchanger

Dimensions & Weight

Electrical supply

Cooling capacity cooling only units (1)


Total Input Power (1)
Cooling capacity heat pump units (1)
Heating capacity heat pump units (1)
Total Input Power cooling/heating mode (1) (2)
Total Input Power cooling/heating mode (1) (3)
Capacity steps
Sound power level
Sound pressure level at 10 m
Sound power level Low Noise version
Sound pressure level Low Noise version at 10 m
Type
Quantity
Fans quantity
Working Ambient temp. cooling / heating mode (4)
Type
Unit water volume (2)
Pump Type
Available pressure (1) (2)
Pressure drop nominal (1) (3)
Working range water leaving temp. cooling/heating (5)
Water connections
H/W/L
Weight pack/without pack cooling only
Weight pack/without pack heat pumps
Voltage/Phases/Frequency
Running current (max) (2)

kW
kW
kW
kW
kW
kW
%
dB(A)
dB(A)
dB(A)
dB(A)

Litres
kPa
kPa
C
inch
mm
kg
kg
V/ph/hz
A

YCSA / YCSA-H
60 T-TP
80 T-TP
100 T-TP
61.2 - 59.3
78.6 - 76.5
96 - 93
23.8 - 25.7
27.4 - 29.7
38.4 - 41.4
65.3 - 63.5
74.3 - 72.2
90 - 87
62.5 - 64.3
81.2 - 83.4
101 - 104.1
22.2 / 23
28 / 29.6
38.3 / 36.5
23 / 24.8
30.1 / 31.8
41.3 / 39.6
0-50-100%
84
85
88
89
56
57
60
61
78
79
80
83
50
51
52
55
Hermetic Scroll (R407C)
2
2
3
(-18C) -10C ~ 46C / -10C ~ 20C
Single Plate Heat Exchanger
179
181
274
278
Multistage horizontal pumps
225
263
223
265
39
42
59
60
(-5C) 6C ~ 15C / 30C ~ 50C
2"
1398 / 1004 / 2103
1400 / 1108 / 2943 1582 / 1140 / 3336
624 / 568
706 / 650
870 / 798
1 030 / 964
636 / 580
720 / 604
890 / 824
1 065 / 1 000
400 / 3 / 50+N+E
46.4
57.7
71
91.3

50 T-TP
49.2 - 47.9
17.9 - 19.3
45.4 - 45.2
54.4 - 54.7
18.7 / 19.7
18.9 / 20

(1) at nominal conditions (2) version P with hydro kit (3) version without hydro kit
(4) -18C with LAK option (5) -5C with glycol
* Provisional data
Nominal conditions: Cooling capacities in kW given for 7C water leaving temperature t 5C and 35C ambient temperature
Heating capacities in kW given for 45C water leaving temperature and 7C ambient temperature

120 T-TP
150 T-TP *
119 - 118.4
156 - 153
43 - 43.6
50 - 53
114 - 110.8
145
119.6 - 122.7
150
43.3 / 39.6
50
46.5 / 42.7
53.5
0-25-50-75-100%
86
88
58
60
82
84
54
56
Hermetic Scroll (R410A)
4
4
-18C ~ 46C / -10C ~ 20C
Dual Plate Heat Exchanger
170
179
200
32

180
30

2 1/2"
2190 / 1101 / 3416 2263 / 1101 / 3770
1 250 / 1 180 1 645 / 1 585
1 280 / 1 220 1 675 / 1 615
100

109

T Three phases supply P Pack H Heat pump

Compatibility table / Codes


Models
Cooling only unit (Pack included)

YCSA 50 TP
668524682

YCSA 60 TP
668526082

YCSA 80 TP
668528082

YCSA 100 TP
668521082

YCSA 120 TP
668551152

YCSA 150 TP
668551502

Heat pump unit (Pack included)

668624682

668626082

668628082

668621082

668651152

668651502

Options (Factory fitted)


Models
Cooling only unit (without Pack)

YCSA 50 T
668524680

YCSA 60 T
668526080

YCSA 80 T
668528080

YCSA 100 T
668521080

YCSA 120 TP
668551150

YCSA 150 TP
668551500

Heat pump unit (without Pack)

668624680

668626080

668628080

668621080

668651150

668651500

Anti-corrosion coated condenser fins (cooling only)

611084646

611086060

611088080

611081010

611081210

611081510

Anti-corrosion coated condenser fins (heat pump)

611085050

611086061

611088081

611081011

611081211

611081511

Copper/copper condenser (cooling only)

611064646

611066060

611068080

611061010

611061210

611061510

Copper/copper condenser (heat pump)

611054646

611056060

611058080

611051010

611051210

611051510

LAK -18C for cooling only unit


Low noise version
Dual Pumps

613112081
613995082

613996086

613998081

613991084

613991285

613991584

NA

NA

613990881

613991085

613991286

613991585

Accessories (Supplied loose)


Mechanical flow switch
Water Filter *

611992021
611300170

Remote control

E-COM-C0602

STANDARD

611300190
613802011

Remote terminal

613802231

613802241

B.M.S. Communication

613802041

613802051

* included with unit version P only for unit without pack. Filter size: 2 for YCSA 50-60-80 and 2 1/2 for YCSA 100-120-150.

49

WATER SYSTEMS

Dimensions and
hydraulic connections
YCSA/YCSA-H 50 and 60 T TP

Rear view

Drawings not a scale

Side view

AIR OUTLET

Front view

317

248

50

1410

A (2")

50

C(23)

347

145 70

447

D(48)
B (2")

206

1691

206

59

(4)16,5

59

886
1004

2103

A- Water intake 2" Gas F.


B- Water outlet 2 Gas F.
C- Auxiliary lines
D- Electrical power supply
E- Water refilling 3/8 Gas F.

YCSA/YCSA-H 80 and 100 T TP

Drawings not a scale


All dimensions in mm

Rear view

Side view

AIR OUTLET

Front view

A (2")
B
G

389

50

50

C(23)

YCSA 80

YCSA 100

1108

1140

1400

1582

2943

3336

970

1002

1265

1318

207

350

317

327

145 70

336

B (2")

436

D(61)

67

(6)16,5

67

D
A

A- Water intake 2" Gas F.


B- Water outlet 2 Gas F.
C- Auxiliary lines
D- Electrical power supply
E- Water refilling 3/8 Gas F.

YCSA/YCSA-H 120 and 150 T TP

Drawings not a scale


All dimensions in mm

WATER OUTPUT 2 1/2"G

22

WATER INTAKE 2 1/2"G

20

60

DRAIN 20 x 20

16.5
B

C
A

50

115.5

870
1101

115.5

AIR OUTLET

YCSA 120

YCSA 150

3416

3770

183

255

1525

1630

1942

1993

2190

2263

199

145

289

211

380

458

Space requirements

YCSA
49 to 156 kW

3000

1000

Model YCSA/H 50-60-80-100

INLET /
OUTLET
WATER

1500

1000

1000

1000

WATER
INTAKE/
OUTLET

3000

Model YCSA/YCSA-H 120 and 150

1500

1000

1000

51

WATER SYSTEMS

HVS Chiller & Heat Pump


Digital Scroll Split version
R407C

A COMPLETE RANGE
FROM 15 kW UP TO 72 kW
YDC_972H
YDC_522H / YOC_762H

Indoor units : see page 72

Variable capacity compressor


(10% to 100%)
Constant water temperature
Energy savings up to 35%
BMS communication
Easy selection software
FSC standard (low ambient
operation)
Plate heat exchanger, no buffer
tank needed
Flexible in use
No glycol required
Water filter standard

52

Options / Accessories
Condenser protection grilles
High static pressure fans
Anticorrosion Epoxy coils
NEW !
Sound attenuation
Softstarter kit
Antifreeze heater for heat exchanger
Interface card for LON Bus
3 way valve for external heating system
Anti vibration mounting
Outdoor temperature sensor
Valve kits
Relay box for several FCU applications
DX Unit
Fan coil load identification

R407C

HVS Split version


15 to 72 kW
Technical features

Models
Performance

Compressor
Air side heat exchanger
Refrigerant side

Water side
(Transformer Box)

Dimensions & Weight


(Unit)

Dimensions & Weight


(Transformer Box)

Electrical supply
Combinations

Cooling capacity cooling only units


Heating capacity heat pump units (1)
Total Input Power
Capacity steps
Sound pressure level at 1 m
Type
Quantity
Fans quantity
Working ambient temp. cool. / heat. mode
Refrigerant connections
Max refrigerant piping length
Max height difference
Pump Type
Water flow nominal
Available pressure nominal (2)
Water connections
Water connections type
Height
Width
Length
Weight cooling only
Height
Width
Depth
Weight cooling only
Voltage / Phases / Frequency

kW
kW
kW
%
dB(A)

mm
m
m
l/h
kPa
inch
mm
mm
mm
kg
mm
mm
mm
kg
V/ph/hz

YDCC 522H
YDCH 522H
15.0
16.5
5
10 - 100
58
Digital Scroll
1
1

YDCC 972H
YDCC1732 H
YDCC 2502 H
YDCH 972H
YDCH 1732 H
YDCH 2502 H
28.0
50.0
72.0
30.5
53.5
76.5
9
9.7 + 6.1
9.7 + 6.1 x 2
6 - 100
4 - 100
3 - 100
59
62
63
Digital Scroll & Scroll
Digital Scroll & 2 x Scroll
Digital Scroll & 3 x Scroll
2
3
4
2
2x2
3x2
-20C~45C / -10C~20C
12/22
16/28
2 x 16/28
3x 16/28
20
5
Circulators (3 speeds)
2150
4100
7200
10350
81
67
67
64
1 1/2"
2"
2"+2"
2 1/2"+2x2"
Threated male
1610
1650
2x1650
2x1650
780
780
2x780
2x780
1330
1500
1500 + 1330
1500 + 1330 + 1330
250
325
325+280
325+280
1000
1200
800
1000
300
80
95
150
170
400 / 3 / 50+N
YDCC 522H
YDCC 972H
YDCC 972H + YOCC 762H YDCC 972H + 2 x YOCC 762H
YDCH 522H
YDCH 972H
YDCH 972H + YOCH 762H YDCH 972H + 2 x YOCH 762H

Nominal cooling capacity based on: leaving water temperature: +7C - Ambient air temperature: 35C DB
Nominal heating capacity based on: leaving water temperature: +40C - Ambient air temperature: 7C DB / 6C WB

(1) Only for heat pump units


(2) At nominal water flow

Compatibility table / Codes

E-COM-C0603

System
Cooling only models
Heat pump models
Transformer boxes
Cooling only models
Heat pump models

15 kW
YDCC 522 H
YDCH 522 H

28 kW
YDCC 972 H
YDCH 972 H

50 kW
YDCC 1732 H
YDCH 1732 H

72 kW
YDCC 2502 H
YDCH 2502 H

YTBC 522 H-V


YTBH 522 H-V

YTBC 97 2H-V
YTBH 972 H-V

YTBC 1732 H-V


YTBH 1732 H-V

YTBC 2502 H-V


YTBH 2502 H-V

Options (factory fitted) Quantity depends on combination selected. See above table in Combinations.
Models
YDCC 522 H
YDCC 972 H
YOCC 762 H
YDCH 522 H
YDCH 972 H
YOCH 762 H
DX Cooling only units
DX-KIT-CO
DX-KIT-CO-S
DX-KIT-CO-L
DX Heat pump units
DX-KIT-HP
DX-KIT-HP-S
DX-KIT-HP-L
Condenser grid
CG
CGS-1
CGL-1
CGS-1
High static pressure fans
HPF
HPF-522
HPF-972
HPF-762
Anticorrosion Epoxy coils
ACF-1
Sound attenuation
CSI
CSI-522
CSI-972
CSI-762
Softstarter kit
SSK
SSK-522
SSK-972
SSK-762
Water filter (included in the transformer box)
WF-1
Standard
Antifreeze heater for heat exchanger and internal piping
AFH-1
Fan coil load identification *
LI-1
With YDC_ unit
* The compressor is inactive when all fan coils are switched off. Operation starts again when at least one fan coil is switched on. ATTENTION! Not applicable for fan coil units with a coil sensor !
Accessories (supplied loose)
Remote central controller (mandatory) *
With YDC_ unit
Interface card for LON Bus
LP-NET-102-000
With YDC_ unit
EH 32
15 - 28 kW
3 way valve for external heating system
EH 40
50 - 72 kW
Anti vibration mounting
AVM-1
Outdoor temperature sensor (for automatic mode change) **
OTS-1
With YDC_ unit
* It is mandatory to have one central controller for HVS unit ** Heat pump only
Accessories for Fan coil units (supplied loose) compatible with HVS only
Valve kit diameter 3/8
VK10-1
Valve kit diameter 1/2
VK15-1
Valve kit diameter 3/4
VK20-1
Valve kit diameter 1
VK25-1
Valve kit diameter 1 1/2
VK40-1
* Valve kit is assembled and composed of an on/off thermal actuator, 3-way valve, shut off and balancing valve
Relay box for up to 4 FCU
RB4-1
Relay box for up to 8 FCU
RB8-1

53

WATER SYSTEMS

System diagram
SPLIT
DX piping (R407C), distance max. 20 m
(i.e. total piping max. 40 m)

Capacity controlled chiller

Max. height difference between condensing unit and


transformer box: 5 m

Transformer
box

Fan coil unit (or any


other kind of water coil

Water piping max.


distance app. 150 m*
(i.e. total piping length
between Transformer
box and furthest Fan
coil unit max. 300m*)

External heating system


(Leaving water temperature
max. 50 C) - optional

* Max. possible length depends on fan coil unit pressure drops and requested water flow rate.

Leaving water temperature down to -5C possible

Digital Scroll

The Digital Scroll Compressor uses a simple


and effective method to modulate the capacity
of an AC, giving unparalleled performance in
the modulation field. To modulate the capacity
the Digital Scroll operates in two stages, the
"loaded state" in which the compressor works
as a normal Scroll compressor at full capacity
and mass flow, and the "unloaded state", where
there is not capacity and mass flow. During the
"unloaded state" there is a separation between
the scrolls. Once the scrolls separate, any gas
passing through is no longer compressed.
Changing the cycle time ("Loaded state" time
and "Unloaded state" time) determines the
capacity modulation of the compressor.

54

Modulation
chamber

Solenoid
valve

Bleed hole

Spring
Lift piston
assembly

SPLIT Model

HVS Split
15 to 72 kW

- Absence of Electromagnetic Interference, compared with


a variable speed compressor, making the system easy
and less sensitve.

HVS Digital is the latest generation of York's Air


Conditioners for cooling and heating. These units use the
Digital Scroll compressor technology that allows to adequate the capacity to the cooling or heating load. Thanks to
this innovative technology our products reach many advantages for our customers.

- High reliability, as there is not necessary to use complicates electronic devices to get the right capacity.
- Not necessary to use buffer tank, thanks to the modulation control

- Energy saving up to 35% compared with conventional


chillers.

- Not necessary to use glycol, as it is possible to use an


intermediate transformer box as a remote evaporator.

- High comfort because of the unit is capable to adjust the


water outlet temperature in a 0,5C, thereby it is possible for the users enjoy always a comfortable ambient
temperature

And many other advantages that you can discover by yourself using HVS units.

Accessories / Operating limits

Valve kits for fan coil units


balancing valve

ON/OFF
actuator

Range:
VK 10-I : kvs 1,6
VK 15-I : kvs 2,5

to HVS

from fan coil

VK 20-I : kvs 4,0


VK 25-I : kvs 6,5

to fan coil

from HVS

VK 40-I : kvs 9,5


shut off valve

3-way valve

Operating limits
Cooling Mode

Heat pump Mode

Max.-outdoor temperature

+45 C

Max.-outdoor temperature

+20 C

Min.-outdoor temperature

-20 C

Min.-outdoor temperature

-10 C

Max.-leaving water temperature +20 C

Max.-leaving water temperature +45 C

Min.-leaving water temperature

Min.-leaving water temperature

-5 C *

+30 C

* Using glycol

For further accessories contact YORK


55

WATER SYSTEMS

System overview

1) Refrigerant connections
2) Water connections
3) Expansion vessel
4) Pressure gauge
5) Safety valve
6) Water pump
7) Flow switch
8) Plate heat exchanger
9) Expansion valve(s)
10) Air bleeding valve

HVS-Transformer Box
e.g. YTB 972-V

HVS-Condensing Unit
e.g. YDCC972H

HVS-System Controller

Indoor Units:
Standard Fan Coils
High Wall Units
Cassettes
Covertible consoles
Blowers
...
Valve Kit

TRANSFORMER BOXES
YTBC / YTBH
Models
Total capacity
kW
Cooling capacities
Water flow
l/h
Heating capacities
Capacity
kW
(YTBH only)
Water flow
l/h
Max. available external
Water pump
kPa
static pressure head *)
Sound pressure level at 3 m free field
dB(A)
Power supply
V/Ph/Hz
Electrical characteristics
Power input -nominal
kW
Running current - nominal
A
H
mm
Dimensions
W
mm
D
mm
Net weight
kg
Type
kg
Water connections
Diameter
Refrigerant piping connections Diameter (nominal)
mm

522
15.0
2150
16.5
2150

972
28.0
4100
30.5
4100

1732
50.0
7200
53.5
7200

2502
72.0
10350
76.5
10350

81

67

67

64

15

20

15
220 - 240 / 1 / 50
270
1.8
1000
800
300
80
1 1/2
12 / 22

Nominal cooling capacity based on: Leaving water temperature: +6 C


Nominal heating capacity based on: Leaving water temperature: +40 C
Horizontal Transformer Boxes available upon request, for more information contact to YORK.

56

350
1100
2.0
3.1
1000
1200
800
1000
300
300
95
150
Threaded male connection
2
2
16 / 28
2 x 16 / 28

20
400 / 3 / 50
1100
3.1
1200
1000
300
170
2 1/2
3 x 16 / 28
*) at nominal water flow

Dimensions and
space requirements

HVS Split
15 to 72 kW

Condensing unit YDCC / YDCH 522 - YOCC / YOCH 762


All data in mm

290

570

250

Crane eyelets

Air flow direction

Unit

Refrigerant tubing
diameter

Liquid side

12

Suction side

22

450

100
1306.5

min. 1 m

1484

1300

1404

1610

497.5

(removable)

min. 0.5 m

min. 0.5 m

92

LW

RW

170-220

1330

Anti vibration mountings

350-400

Condenser grill

780

(optional)

(optional)

Condensing unit YDCC / YDCH 972


All data in mm

340

Unit

Refrigerant tubing
diameter

Liquid side

16

Suction side

28

250

660

Crane eyelets

500

Air flow direction

100
1306.5

1484

1300

min. 1 m

min. 0.5 m

min. 0.5 m
LW

92

1685

1404

497.5

(removable)

RW

170-220

1500

Anti vibration mountings

350-400

Condenser grill

780

(optional)

(optional)

57

WATER SYSTEMS

Dimensions and
refrigerant piping connections
Transformer box YTB_522-V

Suction tube
22 mm

Liquid tube
12 mm

Unit

Water pipe connection

Refrigerant tubing

Weight kg

YTB_522-V

1 1/2 threaded male

12 / 22

80

Water connections 1 1/2


threaded male connection

Pressure gauge
Safety valve

Expansion vessel

1000

Water pump

Air bleeding valve

Plate heat exchanger

Expansion valve

Flow switch

Charge drain valve

Casing with
door at front
800

300

Transformer box YTB_972-V

Liquid tube
16 mm

Unit

Water pipe connection

Refrigerant tubing

Weight kg

YTB_972-V

2 threaded male

16 / 28

95

Suction tube
28 mm

Water connections 2
threaded male connection

Pressure gauge

Safety valve
Expansion vessel

1000

Water pump

Air bleeding valve

Plate heat exchanger


Magnetic valve

Expansion valve

Flow switch

Charge drain valve

Casing with
door at front
800

58

300

HVS Split
15 to 72 kW

Transformer box YTB_1732-V

Liquid tube
16 mm

Unit

Water pipe connection

Refrigerant tubing

Weight kg

YTB_1732-V

2 threaded male

2 x 16/28

150

Suction tube
28 mm

Suction tube
28 mm

Liquid tube
16 mm

Water connections 2
threaded male connection

Pressure
gauge

Air bleeding
valve

Safety
valve

Plate heat
exchanger

1200

Expansion
vessel

Plate heat
exchanger
Expansion
valves
Water
pump

Magnetic
valve

Flow
switch

Charge
drain valve

Casing with
door at front

1000

300

Transformer box YTB_2502-V

Liquid tube
16 mm

Suction tube
28 mm

Unit

Water pipe connection

Refrigerant tubing

Weight kg

YTB_2502-V

2 1/2 threaded male

3 x 16/28

170

Suction tube
28 mm

Liquid tube
16 mm

Water connections 2 1/2


threaded male connection

2x

Pressure
gauge

Air bleeding
valve

Safety
valve

2x Plate heat
exchanger

1200

Expansion
vessel

Plate heat
exchanger
Expansion
valves
Water
pump

Magnetic
valve

Charge
drain valve

Flow
switch

1000

Casing with
door at front

300

59

WATER SYSTEMS

HVS Chiller & Heat Pump


Digital Scroll Compact version
R407C

A COMPLETE RANGE
FROM 15 kW UP TO 72 kW
YDC_972H-C
YDC_522H-C / YOC_762H-C

Indoor units : see page 72

Variable capacity compressor


(10% to 100%)
Constant water temperature
Energy savings up to 35%
BMS communication
Easy selection software
FSC standard (low ambient
operation)
Plate heat exchanger, no buffer
tank needed
Integrated hydro kit
Water filter standard

60

Options / Accessories
Condenser protection grilles
High static pressure fans
Anticorrosion Epoxy coils
NEW !
Sound attenuation
Softstarter kit
Antifreeze heater for heat exchanger
Interface card for LON Bus
3 way valve for external heating system
Anti vibration mounting
Outdoor temperature sensor
Valve kits
Relay box for several FCU applications
Fan coil load identification

R407C

HVS Compact version


15 to 72 kW

Technical features
Models
Performance

Compressor
Air side heat exchanger
Water side heat exchanger

Dimensions & Weight

Electrical supply
Combinations

Cooling capacity cooling only units


Heating capacity heat pump units (1)
Total Input Power
Capacity steps
Sound pressure level at 1 m
Type
Quantity
Fans quantity
Working Ambient temperature cool. / heat. mode
Type
Pump Type
Water flow nominal
Available pressure nominal (2)
Water connections
Water connections type
Height
Width
Length
Weight cooling only
Voltage / Phases / Frequency

kW
kW
kW
%
dB(A)

YDCC 522H-C
YDCH 522H-C
15.0
16.5
5
10 - 100
58
Digital Scroll
1
1

l/h
kPa
inch

2150
81
1 1/2"

mm
mm
mm
kg
V/ph/hz

1610
780
1330
310
YDCC 522H-C
YDCH 522H-C

YDCC 972H-C
YDCC 1732H-C
YDCC 2502H-C
YDCH 972H-C
YDCH 1732H-C
YDCH 2502H-C
28.0
50.0
72.0
30.5
53.5
76.5
9
9.7 + 6.1
9.7 + 6.1 x 2
6 - 100
4 - 100
3 - 100
59
62
63
Digital Scroll & Scroll
Digital Scroll & 2 x Scroll
Digital Scroll & 3 x Scroll
2
3
4
2
2x2
3x2
-20C~45C / -10C~20C
Plate Heat Exchanger
Circulators (3 speeds)
4100
7200
10350
67
67
64
2"
2"+2"
2 1/2"+2x2"
Threated male
1650
1650
1650
780
780
780
1500
1500 + 1330
1500 + 1330 + 1330
400
435 + 285
445 + 285 + 285
400 / 3 / 50+N
YDCC 972H-C
1xYDCC972H-C+1xYOCC762H 1xYDCC972H-C+2xYOCC762H
YDCH 972H-C
1xYDCH972H-C+1xYOCH762H 1xYDCH972H-C+2xYOCH762H

Nominal cooling capacity based on: leaving water temperature: +7C - Ambient air temperature: 35C DB
Nominal heating capacity based on: leaving water temperature: +40C - Ambient air temperature: 7C DB / 6C WB

(1) Only for heat pump units


(2) At nominal water flow

Compatibility table / Codes


Unit
Cooling only models
Heat pump models
Options (factory fitted) Quantity depends on combination selected
Models

15 kW
YDCC 522 H-C
YDCH 522 H-C

YDCC 522 H-C


YDCH 522 H-C
CGS-1
HSF-522

28 kW
YDCC 972 H-C
YDCH 972 H-C

50 kW
YDCC 1732 H-C
YDCH 1732 H-C

YDCC 972 H-C


YDCH972 H-C
CGL-1
HSF-972

72 kW
YDCC 2502 H-C
YDCH 2502 H-C

YOCC 762 H-C


YOCH 762 H-C
CGS-1
HSF-762

Condenser grid YDC_522 / YOC_762


CG
High static pressure fans
HSF
Anticorrosion Epoxy coils
ACF-1
Sound attenuation
CSI
CSI-522
CSI-972
CSI-762
Softstarter kit
SSK
SSK-522
SSK-972
SSK-762
Antifreeze heater for heat exchanger and internal piping
AFH-1
Water Filter (included in the unit)
WF-1
Standard
Fan coil load identification *
LI-1
With YDC_ unit
* The compressor is inactive when all fan coils are switched off. Operation starts again when at least one fan coil is switched on. ATTENTION! Not applicable for fan coil units with a coil sensor !
Accessories (supplied loose)
Remote central controller (mandatory) *
Interface card for LON Bus

E-COM-C0604

LP-NET-102-000
EH 32
3 way valve for external heating system
EH 40
Anti vibration mounting
AVM-1
Outdoor temperature sensor (for automatic mode change) **
OTS-1
* It is mandatory to have one central controller for HVS unit ** Heat pump only

With YDC_ unit


With YDC_ unit
15 - 28 kW
50 - 72 kW
With YDC_ unit

Accessories for Fan coil units (supplied loose) compatible with HVS only
Valve kit diameter 3/8
VK10-1
Valve kit diameter 1/2
VK15-1
Valve kit diameter 3/4
VK20-1
Valve kit diameter 1
VK25-1
Valve kit diameter 1 1/2
VK40-1
* Valve kit is assembled and composed of an on/off thermal actuator, 3-way valve, shut off and balancing valve
Relay box for up to 4 FCU
RB4-1
Relay box for up to 8 FCU
RB8-1

61

WATER SYSTEMS

System diagram
COMPACT
Capacity controlled chiller

Fan coil unit (or any


other kind of water coil

Water piping max.


distance app. 150 m*

* Max. possible length depends on fan coil unit pressure drops and requested water flow rate.

Leaving water temperature down to -5C possible

Digital Scroll

The Digital Scroll Compressor uses a simple


and effective method to modulate the capacity
of an AC, giving unparalleled performance in
the modulation field. To modulate the capacity
the Digital Scroll operates in two stages, the
"loaded state" in which the compressor works
as a normal Scroll compressor at full capacity
and mass flow, and the "unloaded state", where
there is not capacity and mass flow. During the
"unloaded state" there is a separation between
the scrolls. Once the scrolls separate, any gas
passing through is no longer compressed.
Changing the cycle time ("Loaded state" time
and "Unloaded state" time) determines the
capacity modulation of the compressor.

62

Modulation
chamber

Solenoid
valve

Bleed hole

Spring
Lift piston
assembly

COMPACT Model

HVS Compact
15 to 72 kW

The HVS-system is available as a COMPACT version. This version is particularly


designed for process cooling applications for very low brine-temperatures (down to
-5C) but is also applicable for standard AC applications.
The HVS-COMPACT serie contains all hydronic components which normally are located in the transformer box. The hydronic components are installed between the two
coils (see picture) therefore the COMPACT version provides the same dimensions as
the condensing unit of the SPLIT version does. Water connections on the rear side of
the unit (see picture).

Accessories / Operating limits

Valve kits for fan coil units


balancing valve

ON/OFF
actuator

Range:
VK 10-I : kvs 1,6
VK 15-I : kvs 2,5

to HVS

from fan coil

VK 20-I : kvs 4,0


VK 25-I : kvs 6,5

to fan coil

from HVS

VK 40-I : kvs 9,5


shut off valve

3-way valve

Operating limits
Cooling Mode

Heat pump Mode

Max.-outdoor temperature

+45 C

Max.-outdoor temperature

+20 C

Min.-outdoor temperature

-20 C

Min.-outdoor temperature

-10 C

Max.-leaving water temperature +20 C

Max.-leaving water temperature +45 C

Min.-leaving water temperature

Min.-leaving water temperature

-5 C *

+30 C

* Using glycol

For further accessories contact YORK


63

WATER SYSTEMS

Dimensions, space requirements


and hydraulic connections
Model YDCC / YDCH 522 - YOCC / YOCH 762
570

250

Water pipe connection


Threaded male

Crane eyelets

YDC_522

1 1/2

(removable)

YOC_762

1300

1404

1610

290

Unit

92

min. 1 m

1330
Condenser grill
(optional)

Air flow direction

100
1306.5

1484

497.5

450

YDC_522: 1 1/2
YOC_762: 2

min. 0.5 m

min. 0.5 m
LW

RW

170-220

Anti vibration mountings

350-400

780

64

(optional)

HVS Compact
15 to 72 kW

Model YDCC / YDCH 972


340

Unit

Water pipe connection


Threaded male

YDC_972

2 or 2 1/2

250

660

Crane eyelets

1300

min. 1 m

92

1500
Condenser grill
(optional)

Air flow direction

1306.5

100

497.5

500

1484

1685

1404

(removable)

YDC_972 for 28 and 50 kW system: 2


YDC_972 for 72 kW system: 2 1/2

min. 0.5 m

min. 0.5 m
LW

RW

170-220

Anti vibration mountings

350-400

780

(optional)

65

WATER SYSTEMS

Air cooled chiller & heat pump


with centrifugal fan
A COMPLETE RANGE
FROM 40 kW UP TO 140 kW

R407C

YLCC 42-152

Hydro kit GH 200-260 & 600

Indoor units : see page 70

Centrifugal fan
Scroll compressor
Vertical or horizontal discharge
Coaxial heat exchanger
Ductable (inlet/outlet)
Hydro kit (option)
Electronic control

66

Options / Accessories
LAK (-18C)
Shut off valve HP/LP
Anti corrosion coated condenser fins
Antivibration mounting
Flow switch
Remote control
BMS communication
Hydro kit GH

R407C

YLCC W
40 to 141 kW

Technical features

Performance

Compressor
Air side heat exchanger

Water side heat exchanger

Dimensions & Weight

Electrical supply

Models
Cooling capacity cooling only units
kW
Cooling capacity heat pump units
kW
Heating capacity heat pump units
kW
Capacity steps
%
Sound power level
dB(A)
Sound pressure level at 10 m
dB(A)
Type
Quantity
Fans quantity
Air flow (50 Pa)
m3/h
Working Ambient temperature cooling / heating mode
C
Type
Unit water volume (2)
Litres
Pressure drop cooling only (1) (3)
kPa
Working range water leaving temperature cooling/heating
C
Water connections
inch
Height
mm
Width
mm
Depth
mm
Weight for cooling only
kg
Weight for heat pumps
kg
Voltage/Phases/Frequency
V/ph/hz

YLCC / YLCC-H
82
102
71
96.1
71
96
81,5
87
0-50-100%
81
82
84
53
54
56
Hermetic Scroll
2
2
20122
23304
28834
(-18C) -10C ~ 46C / -10C ~ 20C
Coaxial heat exchanger
28
38.2
38.2
43
57
94
-5C ~ 15C / 30C ~ 50C
2 1/2"
1 640
1 864
1 864
2 240
2 891
2 891
929
1 000
1 000
816
962
1 133
857
987
1 146
400 / 3 / 50+N+E

42
40.2
42.2
45.2

62
64
59.5
64.2

79
51

13268

25
16
2"
1 640
2 240
774
695
715

122
152
116
141
111
140
112
132
0-25-50-75-100%
86
90
58
62
4
33247

38312

78.5
20

73.5
46
3

1 864
3 200
1 300
1 389
1 514

1 864
3 200
1 300
1 522
1 568

H = Heat pump

Nominal cooling capacity based on: leaving water temperature: +7C - Ambient air temperature: 35C DB
Nominal heating capacity based on: leaving water temperature: +45C - Ambient air temperature: 7C DB / 6C WB

Compatibility table / Codes


Cooling only horizontal discharge unit
Code

YLCC 42
668544280

YLCC 62
668546280

YLCC 82
668548280

YLCC 102
668541080

YLCC 122
668541280

YLCC 152
668541580

Code

YLCC 42-V
668544281

YLCC 62-V
668546281

YLCC 82-V
668548281

YLCC 102-V
668541081

YLCC 122-V
668541281

YLCC 152-V
668541581

Code

YLCC 42-H
668644280

YLCC 62-H
668646280

YLCC 82-H
668648280

YLCC 102-H
668641080

YLCC 122-H
668641280

YLCC 152-H
668641580

Code

YLCC 42-HV
668644281

YLCC 62-HV
668646281

YLCC 82-HV
668648281

YLCC 102-HV
668641081

YLCC 122-HV
668641281

YLCC 152-HV
668641581

Cooling only vertical discharge unit

Heat pump horizontal discharge unit

Heat pump vertical discharge unit

Options (factory fitted)


LAK (-18C)

Code

613116082

613111082

613111282

Shut off valve HP and LP

Code

613074081

613076081

613078081

613071081

613071282

613071581

Anticorrosion coated condenser fins (cooling only) Code

611080420

611080620

611080820

611080102

611080122

611080152

Anticorrosion coated condenser fins (heat pump) Code

611080421

611080621

611080821

611080103

611080123

611080153

Copper/copper condenser (cooling only)

Code

611060420

611060620

611060820

611060102

611060122

611060152

Copper/copper condenser (heat pump)

Code

611050420

611050620

611050820

611050102

611050122

611050152

E-COM-C0605

Accessories (supplied loose)


AVM mounting

Code

Flow switch

Code

611992021

Remote control

Code

613802011

Remote terminal

Code

613802231

BMS communication

Code

613802041

Hydro kit models

613026080

GH 200

613028180

GH 260

GH 600 S

GH 600 P

67

WATER SYSTEMS

Dimensions, space requirements


and hydraulic connections
YLCC / YLCC-H 42
1

1
2
1986
942

102

106
942

91

100

50(x3)

669

141

483

65

1045

1640

91

37 389

28

148

23
116

2018

106

451

323

3
1

774

Q Minimum free space (1000 mm)


W Minimum free space (500 mm)
E Draining 28 external, length 30 mm (on both side)
R Water connection F 2 Gas
T Electrical connection 22 (3) 28,6 (1) 38 (1)
44

For vertical discharge contact YORK office

2240

YLCC / YLCC-H 62
1

1
2
1986
102

942

91

100

669

141

489

65

1045

1640

91

50x(3)

942

106

37 389

28

148

23
116

2018

106

705

224

929

Q Minimum free space (1000 mm)


W Minimum free space (500 mm)
E Draining 28 external, length 30 mm (on both side)
R Water connection F 2 Gas
T Electrical connection 22 (3) 28,6 (1) 38 (1)
41
2240

68

For vertical discharge contact YORK office

YLCC W
40 to 150 kW

YLCC / YLCC-H 82, 102


1

1
2

2637
1266

102

108
20

1268

91

255

50(x3)

474

140

483

65

1199

1864

91

37 460

28

146

23
115

2670

106

325

675

1000

Q Minimum free space (1000 mm)


W Minimum free space (500 mm)
E Draining 28 external, length 30 mm (on both side)
T Electrical connection 22 (3) 28,6 (1) 38 (1)
Y Water connection F 2 1/2 Gas
U Water connection F 3 Gas

42
2891

For vertical discharge contact YORK office

YLCC / YLCC-H 122, 152


1

1
2940
102

108
20

1437

91

91

255

475

483

65

1193
144

23
113

2982

105

680

620

Q Minimum free space (1000 mm)


W Minimum free space (500 mm)
E Draining 28 external, length 30 mm (on both side)
T Electrical connection 22 (3) 28,6 (1) 38 (1)
Y Water connection F 2 1/2 Gas
U Water connection F 3 Gas

1300

1864

50(x3)

1401

40 460

27

152

40
3200

For vertical discharge contact YORK office


69

WATER SYSTEMS

Hydro kit GH for YLCC-2

Pump
Expansion tank
Buffer tank
Differential flow switch
Air bleeding valve
Service valve
Automatic filling valve
Draining valve
Direct connection to the chiller
GH 200 to 600
Available head pressures

35
30

PRESSURE AVAILABLE GH-200 KIT

30

PRESSURE mcda

PRESSURE mcda

25
25
20
15
10

20

PRESSURE AVAILABLE GH-260 KIT


15

10

5
0

0
3000

3500

4000

4500

5000

5500

6000

6500

7000

7500

8000

6500

8500

30

25

25

PRESSURE mcda

PRESSURE mcda

30

20

PRESSURE AVAILABLE GH-600S KIT


15

10

8000

8500

9000

9500 10000

10500

11000

11500

12000

12500

13000

13500

14000

20

15

PRESSURE AVAILABLE GH-600P KIT


10

70

7000 7500

FLOW l/h

FLOW l/h

12000 12500 13000 13500 14000 14500 15000 15500 16000 16500 17000 17500 18000 18500 19000 19500 20000 20500 21000

19000 19500 20000 20500 21000 21500 22000 22500 23000 23500 24000 24500 25000 25500 26000 26500 27000 27500 28000 28500 29000 29500 30000

FLOW l/h

FLOW l/h

Hydro kit GH
Technical features
Models
Corresponding unit
Capacity
Max pressure
Capacity
Power supply
Motor
Consumption

Buffer tank
Expansion vessel
Pump
Safety valve rating
Weight

Litres
bar
Litres
V/Ph/Hz
kW
Amp
bar
kg

GH 200
YLCC 42
201

GH 260
YLCC 62-82
258

12

18

GH 600 S
YLCC 102-122
605

GH 600 P
YLCC 152
605

35

35

1.9
4.5

3
6.6

6
400/3/50
1.05
1.9

1.46
2.8

137

172

387

427

GH 260
613992601

GH 600 S
613996001

GH 600 P
613996011

Codes
Models

GH 200
613992002

Code

Dimensions and hydraulic connections

HYDRO KIT GH 260

SA

CD

133

CE
883

50

100
928

CE

48

126
1380

E-COM-C0606

883

EA:
SA:
CLL:
CD:
CE:

Water intake, 2 1/2 G


Water outlet, 2 1/2 G
Charge connection, 1/2 G
Drain connection, 1/2 G
Electrical connection (2), dia. 19,7

883

EA:
SA:
CLL:
CD:
CE:

105

148

174

113
100

CD

77

130

305

140
134

152

EA

200

50

77

SA
CLL

143

50

200

CD

305

EA.

SA

1933

EA
CLL

144

CLL

HYDRO KIT GH 600 S/600 P

200

1115

1420

HYDRO KIT GH 200

Water intake, 2 1/2 G


Water outlet, 2 1/2 G
Charge connection, 1/2 G
Drain connection, 1/2 G
Electrical connection (2), dia. 19,7

CE

1000

EA:
SA:
CLL:
CD:
CE:

Water intake, 3 G
Water outlet, 3 G
Charge connection, 1/2 G
Drain connection, 1/2 G
Electrical connection (2), dia. 19,7

71

WATER SYSTEMS

Fan Coil Unit LASER


2 & 4 pipe system
A COMPLETE RANGE FROM 1 kW UP TO 9.5 kW
Option front air intake
6 speed fan
Cabinet factory fitted
Valve factory fitted
Electrical heater factory fitted
Optional plenum
Up to 110 pa static pressure
Thermal or modulating valve
Service valve

CSL00 (Built in)


CSR00 (Wall mounted)
Fan speed selector

CML00 (Built in)


CMR00 (Wall mounted)
Thermostat with manual fan
speed and S/W change over

WITH CABINET

CEL00 (Built in)


CER00 (Wall mounted)
Thermostat with manual
fan speed and automatic
change over

WITHOUT CABINET

CEL20 (Built in)


CER20 (Wall mounted)
Thermostat with auto.
fan speed and automatic
change over

CEL30 (Built in)


CER30 (Wall mounted)
Thermostat with auto. fan
speed and automatic change
over for modulating valve

Selection software
Contact your York Office

Technical features

Model
Cooling capacity (1)
Heating capacity (2)
Pressure drop (4)
Power supply
Input
Sound power level (3)
Sound pressure level at 3 m (3)
Water connections

W
W
kPa
V/Ph/Hz
W
dB(A)
dB(A)
inch

110
1160
1570
3,4

112
1640
2160
7,1

46
48
30

48
50
32

YLV, YLV-AF, YLH, YLH-AF, YLIV, YLIV-AF, YLIH, YLIH-AF


114
216
218
220
222
224
2410
3360
3580
4530
5630
6570
3050
4110
4950
5710
7190
8270
5,8
11,3
13,6
24,1
28,4
18,8
230 / 1 / 50 + E
57
81
86
107
156
147
54
53
56
55
60
60
35
35
37
37
41
42
1/2

Dimensions indicated next page


(1) Cooling capacities based on 7C EWT t 5C indoor temperature 27C DB / 19C WB - (2 pipes - high speed fan) (2 rows)
(2) Heating capacities based on 50C EWT at nominal flow rate indoor temperature 20C - (2 pipes - high speed fan) (2 rows)
(3) Sound level at high speed fan
(4) In cooling mode
For other conditions contact York international

72

226
7410
9330
21

228
9500
11800
36,9

162
63
45

211
67
49

Fan Coil Unit LASER


1 to 9.5 kW

Model
With Cabinet
YLV-YLH

YLV-YLH/AF
Front air intake
Without Cabinet
YLIV-YLIH

YLIV-YLIH/AF
Front air intake

110

112

114

216

218

220

222

224

226

228

110

112

114

216

218

220

222

224

226

228

2 rows
3 rows
4 rows
2 rows
3 rows
4 rows
2 rows
3 rows
4 rows
2 rows
3 rows
4 rows

Options (factory fitted)


Model
Coil and heaters
1 row heating
Kit electrical heater (with relay and safety switch)
Built in thermostat
Fan speed selector
Thermostat with manual fan speed
and S/W change over
Thermostat with manual fan speed, dead band,
automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valve
Parallel connection
For ON/OFF valve one/FCU
For modulating valve one/FCU
3 way valve factory fitted
For 2 pipe systems ON/OFF
For 4 pipe systems ON/OFF
3 way modulating valve factory fitted
For 2 pipe systems Modulating
For 4 pipe systems Modulating
Shut off valves factory fitted
For 2 pipe systems
For 4 pipe systems
Condensate pump
WS sensor change over for CEL/CER
Minimum temperature thermostat

BA1
KREL
CSL00
CML00
CEL00
CEL20
CEL30
CBL20
CBL30
J3A2 (2p)
J3A2 (4p)
J3AM (2p)
J3AM (4p)
DT (2p)
DT (4p)
PC
WS
TM

E-COM-H0601

Accessories (supplied loose)


Remote controllers and thermostat (wall mounted)
Fan speed selector
CSR00
Thermostat with manual fan speed
CMR00
and S/W change over
Thermostat with manual fan speed, dead band,
CER00
automatic change over
Thermostat with automatic fan speed, dead band,
CER20
automatic change over
Thermostat with automatic fan speed, dead band,
CER30
automatic change over for modulating valve
Feets and panel (1)
Set of painted feets
CP1
Set of painted feets + frontal socle
ZL1
Vertical painted back panel
PPV1
Horizontal painted back panel
PPH1
Plemums and air intake (1)
Air intake plenum
PA
Air intake plenum with collars
PAS
90C air intake plenum
PA90
Air intake duct fitting
RCA
Air delivery plenum with collars
PM
90C air delivery plenum
PM90
(1) for check compatibility with the models of FCU see compatibility table on page 90

73

WATER SYSTEMS

Dimensions

NOMENCLATURE
YLV & YLH

YLV-AF & YLH-AF

YLIV & YLIH

YLIV-AF & YLIH-AF

V= vertical
H= horizontal

AF= front air intake


V= vertical
H= horizontal

V= vertical
H= horizontal
I= without Cabinet

AF= front air intake


V= vertical
H= horizontal
I= without Cabinet

LASER SERIES: YLV - YLV/AF

VERTICAL
DIMENSIONS AND WEIGHTS
Dim
A
B
C1
C2
D
E
F
G
H
I
J
N
O

110
648
374
224
233
174
100
40
280
101
85
538
266
113

112
773
499
224
233
174
100
40
280
101
85
538
266
113

114
898
624
224
233
174
100
40
280
101
85
538
266
113

UNIT SIZE
216 218 220
1023 1148 1273
749 874 999
224 224 254
233 233 263
174 174 174
100 100 100
40
40
40
280 280 356
101 101 101
85
85
85
538 538 614
266 266 299
113 113 138

222 224 226


1273 1523 1523
999 1249 1249
254 254 254
263 263 263
174 174 174
100 100 100
40
40
40
356 356 356
101 101 101
85
85
85
614 614 614
299 299 299
138 138 138

228
1773
1499
254
263
174
100
40
356
101
85
614
299
138

Dim
P
Q
R
S
T
U
V
W
X
Z

kg1
kg2

110
48
87
355
50
117
90
47
195
219
109
20
18
19

112
48
87
355
50
117
90
47
195
219
109
20
20
21

114
48
87
355
50
117
90
47
195
219
109
20
23
24

216
48
87
355
50
117
90
47
195
219
109
20
28
30

UNIT SIZE
218 220
48
53
87
87
355 409
50
50
117 135
90
116
47
47
195 238
219 252
109 122
20
20
31
41
32
43

222
53
87
409
50
135
116
47
238
252
122
20
44
46

224
53
87
409
50
135
116
47
238
252
122
20
52
54

226
53
87
409
50
135
116
47
238
252
122
20
52
54

228
53
87
409
50
135
116
47
238
252
122
20
58
61

Notes: 1=YLV - 2=YLV/AF (All dimensions in mm)

LASER SERIES: YLH - YLH/AF


DIMENSIONS AND WEIGHTS

HORIZONTAL

Dim
A
B
C1
C2
D
E
F
G
H
I
J
N
O
P
Q
R
S
T
V
W
X
Y

kg1
kg2

110
648
374
224
233
174
100
40
280
101
85
538
266
113
48
87
355
50
117
28
195
219
205
20
18
19

112
773
499
224
233
174
100
40
280
101
85
538
266
113
48
87
355
50
117
28
195
219
205
20
20
21

UNIT SIZE
114 216 218 220 222 224 226 228
898 1023 1148 1273 1273 1523 1523 1773
624 749 874 999 999 1249 1249 1499
224 224 224 254 254 254 254 254
233 233 233 263 263 263 263 263
174 174 174 174 174 174 174 174
100 100 100 100 100 100
100 100
40
40
40
40
40
40
40
40
280 280 280 356 356 356 356 356
101 101 101 101 101 101 101 101
85
85
85
85
85
85
85
85
538 538 538 614 614 614 614 614
266 266 266 299 299 299 299 299
113 113 113 138 138 138 138 138
48
48
48
53
53
53
53
53
87
87
87
87
87
87
87
87
355 355 355 409 409 409 409 409
50
50
50
50
50
50
50
50
117 117 117 135 135 135
135 135
28
28
28
28
28
28
28
28
195 195 195 238 238 238 238 238
219 219 219 252 252 252 252 252
205 205 205 235 235 235 235 235
20
20
20
20
20
20
20
20
23
28
31
41
44
52
52
58
24
30
32
43
46
54
54
61

Notes: 1=YLH - 2=YLH/AF (All dimensions in mm)

74

Fan Coil Unit LASER


1 to 9.5 kW

LASER SERIES: YLIV - YLIV/AF

VERTICAL
DIMENSIONS AND WEIGHTS
Dim
A
B
C
D
E
F
G
H
I
J
K
L
M
N

110
555
374
215
109
72
40
280
101
85
505
110
55
349
266

112
680
499
215
109
72
40
280
101
85
505
110
55
474
266

114
805
624
215
109
72
40
280
101
85
505
110
55
599
266

UNIT SIZE
216 218 220
930 1055 1180
749 874 999
215 215 245
109 109 109
72
72
72
40
40
40
280 280 356
101 101 101
85
85
85
505 505 581
110 110 125
55
55
60
724 849 974
266 266 299

222
1180
999
245
109
72
40
356
101
85
581
125
60
974
299

224
1430
1249
245
109
72
40
356
101
85
581
125
60
1224
299

226 228
1430 1680
1249 1499
245 245
109 109
72
72
40
40
356 356
101 101
85
85
581
581
125 125
60
60
1224 1474
299 299

Dim
O
P
Q
R
S
T
U
V
W
X
Y
Z

kg

110
113
48
87
355
50
117
90
47
195
219
200
109
20
10

112
113
48
87
355
50
117
90
47
195
219
200
109
20
13

114
113
48
87
355
50
117
90
47
195
219
200
109
20
16

216
113
48
87
355
50
117
90
47
195
219
200
109
20
19

UNIT SIZE
218 220
113 138
48
53
87
87
355 409
50
50
117 135
90 116
47
47
195 238
219 252
200 230
109 122
20
20
22
29

222
138
53
87
409
50
135
116
47
238
252
230
122
20
31

224
138
53
87
409
50
135
116
47
238
252
230
122
20
38

226
138
53
87
409
50
135
116
47
238
252
230
122
20
38

228
138
53
87
409
50
135
116
47
238
252
230
122
20
42

(All dimensions in mm)

LASER SERIES: YLIH - YLIH/AF


DIMENSIONS AND WEIGHTS

HORIZONTAL

Dim 110 112 114


A
574 699 824
B
374 499 624
C
215 215 215
D
128 128 128
E
72
72
72
F
40
40
40
G
280 280 280
H
101 101 101
I
85
85
85
J
505 505 505
K
110 110 110
L
55
55
55
M
349 474 599
N
266 266 266
O
113 113 113
P
48
48
48
Q
87
87
87
R
355 355 355
S
50
50
50
T
117 117 117
V
28
28
28
W
195 195 195
X
219 219 219
Y
205 205 205

20
20
20
kg
10
13
16
(All dimensions in mm)

216
949
749
215
128
72
40
280
101
85
505
110
55
724
266
113
48
87
355
50
117
28
195
219
205
20
19

UNIT SIZE
218 220 222 224 226 228
1074 1199 1199 1449 1449 1699
874 999 999 1249 1249 1499
215 245 245 245 245 245
128 128 128 128 128 128
72
72
72
72
72
72
40
40
40
40
40
40
280 356 356 356 356 356
101 101 101 101 101 101
85
85
85
85
85
85
505 581 581 581 581 581
110 125 125 125 125 125
55
60
60
60
60
60
849 974 974 1224 1224 1474
266 299 299 299 299 299
113 138 138 138 138 138
48
53
53
53
53
53
87
87
87
87
87
87
355 409 409 409 409 409
50
50
50
50
50
50
117 135 135 135 135 135
28
28
28
28
28
28
195 238 238 238 238 238
219 252 252 252 252 252
205 235 235 235 235 235
20
20
20
20
20
20
22
29
31
38
38
42

75

WATER SYSTEMS

Fan Coil Unit LOW BODY


2 & 4 pipe system
A COMPLETE RANGE FROM 0.8 kW UP TO 2.7 kW
6 speed fan
Cabinet factory fitted
Valve factory fitted
Electrical heater factory fitted
Thermal or modulating valve
Service valve
WITH CABINET

CSL00 (Built in)


CSR00 (Wall mounted)
Fan speed selector

CML00 (Built in)


CMR00 (Wall mounted)
Thermostat with manual fan
speed and S/W change over

CEL00 (Built in)


CER00 (Wall mounted)
Thermostat with manual
fan speed and automatic
change over

WITHOUT CABINET

CEL20 (Built in)


CER20 (Wall mounted)
Thermostat with auto.
fan speed and automatic
change over

CEL30 (Built in)


CER30 (Wall mounted)
Thermostat with auto. fan
speed and automatic change
over for modulating valve

Selection software
Contact your York Office

Technical features

Model
Cooling capacity (1)
Cooling capacity (1)
Heating capacity (2)
Pressure drop (3)
Power supply
Sound power level
Sound pressure level at 3 m
Water connections

W
W
W

2 rows
3 rows
1 rows
kPa
V/Ph/Hz
dB(A)
dB(A)
inch

110
832
913
1167
7

112
1054
1266
1691
1,7

49
31

50
32

YLVR - YLIVR
114
1493
1790
2319
3,8
230 / 1 / 50 + E
53
35
1/2

Dimensions indicated next page


(1) Cooling capacities based on 7C EWT t 5C indoor temperature 27C DB / 19C WB - (2 pipes - high speed fan)
(2) Heating capacities based on 70C EWT t 10C indoor temperature 20C - (2 pipes - high speed fan)
(3) In cooling mode 2 rows
For other conditions contact York international

76

216
2041
2327
3029
9

218
2356
2714
3552
11,7

53
35

55
37

Fan Coil Unit LOW BODY


0.8 to 2.7 kW

Model
With Cabinet
YLVR
Without Cabinet
YLIVR

110

112

114

216

218

110

112

114

216

218

2 rows
3 rows
2 rows
3 rows

Options (factory fitted)


Model
Coil and heaters
1 row heating
Kit electrical heater (with relay and safety switch)
Built in thermostat
Fan speed selector
Thermostat with manual fan speed
and S/W change over
Thermostat with manual fan speed, dead band,
automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valve
Parallel connection
For ON/OFF valve one/FCU
For modulating valve one/FCU
3 way valve factory fitted
For 2 pipe systems ON/OFF
For 4 pipe systems ON/OFF
3 way modulating valve factory fitted
For 2 pipe systems Modulating
For 4 pipe systems Modulating
Shut off valves factory fitted
For 2 pipe systems
For 4 pipe systems

BA1
KREL
CSL00
CML00
CEL00
CEL20
CEL30
CBL20
CBL30
J3A2 (2p)
J3A2 (4p)
J3AM (2p)
J3AM (4p)
DT (2p)
DT (4p)

Condensate pump

PC

WS sensor change over for CEL/CER

WS

Minimum temperature thermostat

TM

Accessories (supplied loose)


Remote controllers and thermostat (wall mounted)
Fan speed selector
CSR00
Thermostat with manual fan speed
CMR00
and S/W change over
Thermostat with manual fan speed, dead band,
CER00
automatic change over
Thermostat with automatic fan speed, dead band,
CER20
automatic change over
Thermostat with automatic fan speed, dead band,
CER30
automatic change over for modulating valve

E-COM-H0602

(1) for check compatibility with the models of FCU see compatibility table on page 90

77

WATER SYSTEMS

NOMENCLATURE

Dimensions

YLVR

YLIVR

R= low body
V= vertical

R= low body
V= vertical
I= without cabinet

LOW BODY: YLVR

DIMENSIONS AND WEIGHTS


Dim
A
B
C
D
E
G
H
J
N
O
P
Q
R
S
T
U
V
W
X
Z

kg

110
648
374
254
174
100
170
101
430
245
154
31
47
304
88
87
65
47
84
214
109
20
15

(All dimensions in mm)

78

112
773
499
254
174
100
170
101
430
245
154
31
47
304
88
87
65
47
84
214
109
20
17

UNIT SIZE
114
898
624
254
174
100
170
101
430
245
154
31
47
304
88
87
65
47
84
214
109
20
22

216
1023
749
254
174
100
170
101
430
245
154
31
47
304
88
87
65
47
84
214
109
20
23

218
1148
874
254
174
100
170
101
430
245
154
31
47
304
88
87
65
47
84
214
109
20
26

Fan Coil Unit LOW BODY


0.8 to 2.7 kW

LOW BODY: YLIVR

DIMENSIONS AND WEIGHTS


Dim
A
B
C
D
E
G
H
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z

kg

110
555
374
230
108
73
170
101
395
61
349
127
245
154
31
47
304
88
87
65
47
84
214
201
109
20
9

112
680
499
230
108
73
170
101
395
61
474
127
245
154
31
47
304
88
87
65
47
84
214
201
109
20
11

UNIT SIZE
114
805
624
230
108
73
170
101
395
61
599
127
245
154
31
47
304
88
87
65
47
84
214
201
109
20
14

216
930
749
230
108
73
170
101
395
61
724
127
245
154
31
47
304
88
87
65
47
84
214
201
109
20
16

218
1055
874
230
108
73
170
101
395
61
849
127
245
154
31
47
304
88
87
65
47
84
214
201
109
20
19

(All dimensions in mm)

79

WATER SYSTEMS

Compatibility tables for FCU


LASER and LOW BODY

CSL00 (Built in)


CSR00 (Wall mounted)
Fan speed selector

CEL00 (Built in)


CER00 (Wall mounted)
Thermostat with manual fan
speed and automatic change over

CEL20 (Built in)


CER20 (Wall mounted)
Thermostat with auto. fan
speed and automatic change over

CEL30 (Built in)


CER30 (Wall mounted)
Thermostat with auto. fan
speed and automatic change
over for modulating valve

FEATURES CEL/CER

CML00 (Built in)


CMR00 (Wall mounted)
Thermostat with manual fan
speed and S/W change over

Dead band for change over 5C or 2C (factory set


2C for 4 pipes and 5C for 2 pipes)
Manual fan speeds or automatic (models 20 and 30)
Thermostated fan control or continuous fan running
Option water sensor WS for change over on coil (for
2 pipes)
Led indicated status summer, winter or dead band
Temperature setting for 7 to 30C (comfort 20-25C)
Plastic pins for limiting temperature range

Input for window contact


Input for Economy/ occupancy mode
Output for remote alarm
Filter alarm 600 or 1200 running hours (factory set
1200 hours)
With electrical heater post ventilation
With Air sensor in the air intake destratification function (CEL only)

COMPATIBILITY TABLE THERMOSTAT / VALVES / HEATERS / PARALLEL CONNECTION / WATER SENSOR / MINIMUM TEMPERATURE THERMOSTAT
Valves for 2 pipes
Factory fitted thermostat (built in)
CSL00

Fan speed selector

CML00 Thermostat with manual fan speed


and S/W change over
CEL00

Thermostat with manual fan speed, dead band,


automatic change over

CEL20

Thermostat with automatic fan speed, dead band,


automatic change over

CEL30

Thermostat with automatic fan speed, dead band,


automatic change over for modulating valve

Remote controllers and thermostats (wall mounted)


CSR00

Fan speed selector a

CMR00 Thermostat with manual fan speed


and S/W change over
CER00

Thermostat with manual fan speed, dead band,


automatic change over

CER20

Thermostat with automatic fan speed, dead band,


automatic change over

CER30

Thermostat with automatic fan speed, dead band,


automatic change over for modulating valve
Compatible
Not compatible

80

Valves for 4 pipes

J3A2 (2p) J3AM (2p) J3A2 (4p) J3AM (4p)

Heaters
KREL

Parallel connection
ON/OFF Modulating
CBL20

CBL30

Water
sensor

Min. Temp.
Thermostat

WS

TM

Compatibility tables
LASER and LOW BODY
COMPATIBILITY OPTIONS / ACCESSORIES / MODELS

Code

designation

YLV

STANDARD
LASER
YLH
YLV-AF YLH-AF
YLIV

CONCEALED
YLIH YLIV-AF YLIH-AF

LOW BODY

YLVR

YLIVR

Coils and heaters**


BA1**
KREL**

Additionnal 1 row heating


Kit electrical heater with safety thermostat and relay

Factory fitted thermostat


CSL00
CML00
CEL00
CEL20
CEL30

Fan speed selector (buit in)


Thermostat with manual fan speed
and S/W change over (buit in)
Thermostat with manual fan speed,
dead band, automatic change over (buit in)
Thermostat with automatic fan speed,
dead band, automatic change over (buit in)
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valves (buit in)

Compatible with electrical heaters


Compatible with electrical heaters

Remote controllers and thermostats


CSR00
CMR00
CER00
CER20
CER30
CBL20
CBL30

Fan speed selector (wall mounted)


Thermostat with manual fan speed
and S/W change over (wall mounted)
Thermostat with manual fan speed,
dead band, automatic change over (wall mounted)
Thermostat with automatic fan speed,
dead band, automatic change over (wall mounted)
Thermostat with automatic fan speed, dead band,
autom. change over for modulating valves (wall mounted)
Parallel connection for ON/OFF valve
Parallel connection for modulating valve

Compatible with electrical heaters


Compatible with electrical heaters

Valves / Condensate pump / Water sensor / Minimum temperature thermostat (Factory fitted)
J3A2 (2p)
J3A2 (4p)
J3AM (2p)
J3AM (4p)
DT (2p)
DT (4p)
PC
WS
TM

3-way 4-ports on/off valves for 2-pipe systems


3-way 4-ports on/off valves for 4-pipe systems
3-way 4-ports modulating valves for 2-pipe systems
3-way 4-ports modulating valves for 4-pipe systems
Shut-off valves for 2-pipe systems
(in addition to H3A2/J3AM valves)
Shut-off valves for 4-pipe systems
(in addition to H3A2/J3AM valves)
Condensate pump
Water sensor
Minimum temperature thermostat

Compatible with CEL/CER

Feets and panels


CP1
ZL1
PPV1
PPH1

Set of painted feet


Set of feet + frontal socle
Vertical painted back panel
Horizontal painted back panel

External air intake


PA
PAS
PA90
RCA
PM
PM90

Air intake plenum


Air intake plenum collars
90 air intake plenum
Air intake duct fitting
Air delivery plenum with collars
90 air delivery plenum

**

Compatible
Compatible with conditions
Not compatible
Maximum of rows is indicated in the documentation, the maximum number of rows includes the heating row or electrical heater.

81

WATER SYSTEMS

Cassette 600 x 600


2 & 4 pipe system
A COMPLETE RANGE FROM 2.3 kW TO 5.4 kW
Valve kit factory fitted
Wall mounted control or infrared control
Integrated condensate pump with
alarm level

Control XE 99
(HKY)

Wired control AFC02A


(HKY)

HKY-HKH 08-2 to 22-2 (2 pipes)


HKY 08-4 to 22-4 (4 pipes)

Infrared remote control


(HKH) (2 pipes only)

Technical features

Model
Cooling capacity total
W
Sensible cooling capacity
W
Heating capacity
W
Cold water pressure drop
kpa
at nominal conditions
Hot water pressure drop
at nominal conditions (4 pipes) kpa
Electrical data
Power supply
V/ph/Hz
Power input at high speed
W
Noise level
Sound power level
dB(A)
Sound pressure level at 3m
dB(A)
Electric heater (accessory) (only 2 pipes)
Capacity
kW
Connections
Cold coil
Hot coil
Condensate pipe
Dimensions and weight with valve
Unit (W x D x H)
mm
Panel (W x D x H)
mm
Weight
kg

08-2
2 350
1 700
3 100

HKY-HKH 2 pipes
15-2
3 950
2 950
4 900

22-2
5 450
3 940
6 200

08-4
2 000
1 450
2 890

HKY 4 pipes
15-4
3 710
2 810
4 330

22-4
4 480
3 240
4 700

10

15

17

9.5

15

16.5

6.6

24.2

230 / 1 / 50
66

59

72

66

59

72

48
30

52
34

56
38

48
30

52
34

56
38

GM 1/2

GM 3/4

GM 3/4

575 x 575 x 300


660 x 660 x 50
21

23.8

24.5

Cooling capacities based on 7C EWT t 5C Indoor temperature 27C DB / 19C WB


Heating capacities based on 50C EWT at nominal flow rate Indoor temperature 20C (2 pipes)
Heating capacities based on 70C EWT t 10C Indoor temperature 20C (4 pipes)

82

GM 1/2

GM 1/2
12 mm inside diameter

21

23.8

24.5

Cassette 600 x 600


2.3 to 5.4 kW

2 PIPE CASSETTES HKY and HKH


With valve factory fitted
Models
Code

HKY 08-2-V
666011261

HKY 15-2-V
666011861

HKY 22-2-V
666012461

HKH 08-2-V
666021271

HKH 15-2-V
666021871

HKH 22-2-V
666022471

Code

HKY 08-2
666011271

HKY 15-2
666011871

HKY 22-2
666012471

HKH 08-2
666021281

HKH 15-2
666021881

HKH 22-2
666022481

HKY 15-2-E-V
2 kW
666011880

HKY 22-2-E-V
3 kW
666012480

HKH 08-2-E-V
2 kW
666021280

HKH 15-2-E-V
2 kW
666021880

HKH 22-2-E-V
3 kW
666022480

Options (Factory fitted)


Without valves
Models

With electrical heaters and valve factory fitted


Models
HKY 08-2-E-V
Heaters
capacities
2 kW
Code
666011280
Minimum quantity is 20

Accessories (Supplied loose)


AFC02A Control
XE 99 Control
Remote sensor for XE 99

Code
Code
Code

Valve kit ASV02-K4 1/2 *


Valve kit ASV03-K4 3/4 *

Code
Code

Heaters

capacities
Code

611130086
613909981
613901286

Infrared control included


Infrared control included
Infrared control included

611150461
N/A

N/A
611150462

611150461
N/A

N/A
611150462

2 kW
611760231 + 613120051

3 kW
611760331 + 613120051

2 kW
611760231

3 kW
611760331

For HYK it is necessary the contactor


* Drain pan included

4 PIPE CASSETTES HKY


With valve factory fitted
Models
Code

HKY 08-4-V
666011251

HKY 15-4-V
666011851

HKY 22-4-V
666012451

Code

HKY 08-4
666011241

HKY 15-4
666011841

HKY 22-4
666012441

Options (Factory fitted)


Without valves
Models
Minimum quantity is 20

PRODUCT NOMENCLATURE

Accessories (Supplied loose)


AFC02A Control

Code

611130086

XE 99 Control

Code

613909981

Remote sensor for XE 99

Code

613901286

Wired control

Valve kit ASV01-K4 1/2 hot coil

Code

611150460

Size

HKY - 08 - 2 - E - V

2 pipes
Valve kit ASV02-K4 1/2 cold coil * Code

611150461

N/A

Valve kit ASV03-K4 3/4 cold coil * Code

N/A

611150462

E-COM-H0603

Electrical heater
Valve

N/A Not available


* Drain pan included

83

WATER SYSTEMS

Dimensions and
hydraulic connections
HKY-HKH 08 / 15 / 22 (2 pipes)

120
240
215

RENEWAL AIR DUCT


PREPUNCHED HOLE

ELECTRICAL
CONNECTING
BOX

145

2,9(8)

0
23
0
0
2

2
13
2
11

30

AIR OUTLET DUCT


PREPUNCHED HOLE
VIEW FROM "B"

Cold water
intake/outlet

35

CASSETTE
Cold w
CASING

AIR
DIFFUSER
PANEL

Location side of
the control
valves and the
condensed
water tray

Air bleding
valve
Condensed
water drain
connection

HKY 08 / 15 / 22 (4 pipes)

120
240
215

RENEWAL AIR DUCT


PREPUNCHED HOLE

ELECTRICAL
CONNECTING
BOX

145

2,9(8)

0
23
0
0
2

2
13
2
1
1

45
30

AIR OUTLET DUCT


PREPUNCHED HOLE
CASSETTE
CASING

AIR
DIFFUSER
PANEL

84

Cold water
intake/outlet

Location side of
the control
valves and the
condensed
water tray

35

Hot
water
intake/
outlet

Air bleding
valve
Condensed
water drain
connection

Cassette 600 x 600


2.3 to 5.4 kW

Features / Accessories
Valve kit
- Diameter 1/2 for size 08 and 15
- Diameter 3/4 for size 22
- Factory fitted
- Thermal valve ON/OFF
- Insulated drain pan
- With service valve as standard

Easy to
connect
Save time !

Removeable electrical
box for easy fitting

Electrical heater
(accessory only for 2 pipes)

Condensate pump
with alarm level

Controls

Infrared remote control


(2 pipes only)
Digital display
Infra red control
Set point selection
Cooling, Heating mode, automatic
Fan speed selection
Sleep mode (night operation)
Timer
Emergency operation switch
Auto restart
Random start
1 stage in cooling mode
2 stages in heating mode
(heater always second stage)

Basic control AFC02A

Control XE 99

3 Operating modes
- ON/OFF
- Cooling
- Heating
Room temperature setting
3 fan speeds
Auto/continuous fan mode
1 stage in cooling mode
1 stage in heating mode

Digital display
Reading set point or ambient temperature
Mode ON/OFF (continuous running of the fan)
Mode AUTO (fan stops when set point is reached)
Cooling or heating
Energy saving mode (free contact) (clock or door contact
for instance)
1 stage in cooling mode
2 stages in heating mode
(2 stages only 2 pipe cassettes)
Alarm sensor defect
3 fan speeds
Auto restart
Minimum and maximum set point
Remote sensor
85

WATER SYSTEMS

Large Cassette

4 cm

A RANGE UP TO 11.6 kW
Air sweep (HKH)
Wall mounted control or infrared control
Integrated condensate pump
Valve kit
HKY-HKH 24 to 44
Infrared remote control (HKH)
Wireless or wired version available
5 operations modes
(Cool/Heat/Auto/Dry/Fan)
Sleep mode
Room temperature setting
Fan speed selection
Timer
Filter cleaning indicator
LCD display
Indoor unit LED Diagnostic Function

Wired control AFC02A (HKY)


3 Operating modes
- ON/OFF
- Cooling
- Heating
Room temperature setting
3 fan speeds
Auto/continuous fan mode
1 stage in cooling mode
1 stage in heating mode

Remote start/stop for HKH


Up to 16 indoor units can be controlled. (Maximum wiring length: 500 m)
With option PCB link.
Number of PCB link = (number of units x 2) - 1

Valve kit ASV02C

Clock

86

- Pipe connection 3/4


- Ready to install
- Thermal valve ON/OFF
- Insulated flexible pipes
- Insulated valve body
- With service valve (loose)

Large Cassette
6.9 to 11.6 kW

Technical features
Model
Cooling capacity
Heating capacity
Power supply
Fan type
Airflow (HS)
Power input
Fan motor protection
Noise level
Sound pressure level at 2,5 m
LS / MS / HS
Dimensions and weight
Unit (H x W x D)
Panel (H x W)
Weight
Condensate drain size
Water connections
Type
Diameter Inlet / Outlet

HKY-HKH 24
6 900
8 300

W
W
V/Ph/Hz
m3/h
W

1 360
110

dB(A)

42 / 44 / 47

mm
mm
kg
mm

HKY-HKH 34
9 900
11 500
230 / 1 / 50 + E
Turbo Fan / Direct Drive
1 630
125
Auto Reset Thermal Overload

HKY-HKH 44
11 600
13 500

43 / 46 / 49

44 / 47 / 51

1 740
135

350 x 836,5 x 827,5


950 x 950
60
19.05
Male
3/4

Cooling capacities based on 7C EWT t 5C Indoor temperature 27C DB / 19C WB


Heating capacities based on 50C EWT at nominal flow rate Indoor temperature 20C

Accessories
Model

HKY 24

HKY 34

HKY 44

HKH 24

HKH 34

HKH 44

Valve kit

Code

ASV02C

PCB link

Code

025T 30012-000

Wired control

Code

AFC02A

Infrared control included

Models HKH must be installed with ON/OFF valve ASV02C.

Dimensions and minimum spaces


870

950
636

380

836.5

525

Mounting
Hole
827.5

505 629 950

870 786

786

Mounting
Hole
350

E-COM-H0604

Min. 0.5 m

Min. 0.5 m

Min. 0.5 m

Max. 3.0 m

Max. 3.0 m

Max. 3.0 m

Beam

525

Obstacle
Floor

87

WATER SYSTEMS

High wall

A RANGE FROM 1.5 TO 2.8 kW


Wall mounted control or infrared
control
Air sweep (HHH)
Valve kit ASV01C
Condensate pump (accessory)

Infrared remote control (HHH)


Wireless or wired version available
5 operations modes
(Cool/Heat/Auto/Dry/Fan)
Sleep mode
Room temperature setting
Fan speed selection
Timer
Filter cleaning indicator
LCD display
Indoor unit LED Diagnostic Function

Remote start/stop for HHH


Up to 16 indoor units can be controlled. (Maximum wiring length: 500 m)
With option PCB link.
Number of PCB link = (number of units x 2) - 1

Clock

88

HHY-HHH 05-07

HHY-HHH 11
Wired control AFC02A (HHY)
3 Operating modes
- ON/OFF
- Cooling
- Heating
Room temperature setting
3 fan speeds
Auto/continuous fan mode
1 stage in cooling mode
1 stage in heating mode

High wall
1.5 to 2.8 kW

Condensate pump AMP01B

Valve kit ASV01C


- Pipe connection 1/2
- Ready to install
- Thermal valve ON/OFF
- Insulated flexible pipes
- Insulated valve body
- With service valve (loose)

Float switch

Pump

Technical features
Model
Total cooling capacity
Sensible capacity
Heating capacity
Electrical data
Supply
Input
Noise level
Sound power level
Sound pressure level at 3m
Dimensions and weight
Heigh
Width
Depth
Weight

W
W
W

HHY-HHH 05
1580
1339
2250

HHY-HHH 07
2190
1856
2930

HHY-HHH 11
2800
2372
3920

V/ph/Hz
W
Amps

20
0,09

230 / 1 / 50 + E
32
0,13

60
0,28

dB(A)
dB(A)

50
32

54
36

57
39

mm
mm
mm
kg

290
799
181
8

315
1019
180
12

Cooling capacities based on 7C EWT t 5C Indoor temperature 27C DB / 19C WB


Heating capacities based on 50C EWT at nominal flow rate Indoor temperature 20C

Accessories

E-COM-H0605

Model
Unit

HHY 05

HHY 07

HHY 11

HHH 05

HHH 07

Wired control

Code

AFC02A

Infrared control included

Valve kit

Code

ASV01C

ASV01C* (Mandatory)

Condensate pump

Code

Electrostatic filter

Code

PCB link

Code

HHH 11

AMP01B
AMA01N

AMA02N
N/A

AMA01N

AMA02N

025T 300012-000

* Models HHH must be installed with ON/OFF valve ASV01C.

89

WATER SYSTEMS

Convertible console

4.1 AND 5.5 kW


Wall mounted control or infrared control
Air sweep (HCH)
Valve kit ASV01C
Condensate pump (accessory)
Floor / Ceiling
HCY-HCH 10 and 14
Infrared remote control (HCH)
Wireless or wired version available
5 operations modes
(Cool/Heat/Auto/Dry/Fan)
Sleep mode
Room temperature setting
Fan speed selection
Timer
Filter cleaning indicator
LCD display
Indoor unit LED Diagnostic Function

Remote start/stop for HCH


Up to 16 indoor units can be controlled. (Maximum wiring length: 500 m)
With option PCB link.
Number of PCB link = (number of units x 2) - 1

Clock

90

Wired control AFC02A (HCY)


3 Operating modes
- ON/OFF
- Cooling
- Heating
Room temperature setting
3 fan speeds
Auto/continuous fan mode
1 stage in cooling mode
1 stage in heating mode

Convertible console
4.1 to 5.5 kW

Condensate pump AMP01B

Valve kit ASV01C


- Pipe connection 1/2
- Ready to install
- Thermal valve ON/OFF
- Insulated flexible pipes
- Insulated valve body
- With service valve (loose)

Float switch

Pump

Technical features
Model
Fan speed
Total cooling capacitiy
Sensible capacity
Heating capacitiy
Electrical data
Supply
Input
Noise level
Sound power level
Sound pressure level at 3m
Dimensions and weight
Heigh
Width
Depth
Weight

W
W
W

10
High
4110
3480
5825

14
High
5550
4658
7770

V/ph/Hz
W
Amps

63
0,29

77
0,36

dB(A)
dB(A)

55
37

56
38

mm
mm
mm
kg

655
990
199
27

655
990
199
29

230 / 1 / 50 + E

Cooling capacities based on 7C EWT t 5C Indoor temperature 27C DB / 19C WB


Heating capacities based on 50C EWT at nominal flow rate Indoor temperature 20C

Accessories

E-COM-H0606

Model

HCY 10

HCY 14

HCH 10

HCH 14

Wired control

Code

AFC02A

Infrared control included

Valve kit

Code

ASV01C

ASV01C * (Mandatory)

Condensate pump

Code

PCB link

Code

AMP01B
N/A

025T 30012-000

* Models HCH must be installed with ON/OFF valve ASV01C.

91

WATER SYSTEMS

Blowers
A COMPLETE RANGE FROM 4 kW UP TO 24 kW
Horizontal air return
Twin centrifugal fans
High static pressure up to 250 Pa
2 and 4 pipe systems
Air distribution plenum
Electric heater option
Optional paint finish

CSR00 (Wall mounted)


Fan speed selector

CMR00 (Wall mounted)


Thermostat with manual fan
speed and S/W change over

YEFB 130-440

CER00 (Wall mounted)


Thermostat with manual
fan speed and automatic
change over

CER20 (Wall mounted)


Thermostat with auto.
fan speed and automatic
change over

CER30 (Wall mounted)


Thermostat with auto. fan
speed and automatic change
over for modulating valve

Technical features with 50 Pa of external static pressure


Model
Total cooling capacity [kW]

(1)

Heating capacity [kW]

(2)

Air volume [m3/h]

Max. available external static pressure [Pa]


Soun pressure level [dB(A)](3)

Power supply [V-ph-Hz]


Water connections

YEFB
max
med
min
max
med
min
max
med
min
max
med
min

130
6.01
5.13
3.22
7.90
6.61
3.96
1153
916
494
100
56
51
41

140
6.92
5.81
3.49
8.90
7.32
4.20
1130
898
484
100
56
51
41

230
8.81
7.27
6.08
12.34
9.84
8.01
2158
1553
1174
175
60
54
49

G 1/2" F

G 1/2" F

G 1/2" F

(1) Room temperature 27C d.b., 48% R.H. - Water temperature 7/12 C
(2) Room temperature 20C, 50% R.H. - Water inlet temperature: 50C - Water flow values as Cooling,
accordingly to the EUROVENT standards and UNI ENV 1397
(3) Sound pressure level in 1 meter distance open field and 0 Pa external static pressure

240
330
10.61
11.15
8.55
9.39
7.01
7.51
14.62
15.20
11.36
12.49
9.04
9.71
2116
2639
1523
1994
1151
1422
175
250
60
60
54
54
49
48
230 - 1- 50
G 1/2" F
G 1/2" F

340
14.06
11.58
9.00
18.84
15.07
11.33
2587
1955
1394
250
60
54
48

430
17.86
16.28
14.40
24.38
21.83
18.90
4129
3505
2853
250
67
64
59

440
23.31
20.95
18.21
30.36
26.79
22.77
4048
3436
2797
250
67
64
59

G 1/2" F

G 1" M

G 1" M

Blowers
4 to 24 kW

Dimensions
Mod.

Mod.

100200

989,6

800,0

331,0

948,6

290,0

21,5

362,0

158,0

100200

331,0

996,6

324,5

300

1239,6

900,0

350,0

1198,6

309,0

21,5

462,0

158,0

300

350,0

1246,6

300,0

400

1633,0

900,0

439,3

1592,0

398,3

21,5

450,0

158,0

400

439,3

1640,0

319,8

A
B

H
A
G
C
E
91.5
160
C
78

200

Options / Accessories
Models

YEFB 130-140

YEFB 230-240

YEFB 330-340

YEFB 430-440

Options (factory fitted)


Auxiliary hot water coil (2 or 3 rows)

Paint finish

F5 Filter

Accessories (supplied loose)


Valve kits 3 ways 4 ports
On/off 2 and 4 pipes
Modulating 2 and 4 pipes

Code
Code

Electrical heaters
Capacity

E-COM-H0608

Controls
CSR00 fan speed selector
CMR00 2 and 4 pipe, on/off valves
CER00 2 and 4 pipe, on/off valves (or El. heater)
CER20 2 and 4 pipe, on/off valves (or El. heater)
CER30 2 and 4 pipe, modulating valves
Discharge plenum

Code

Condensate pump

Code

Available

J3B2
J3BM

J3C2
J3CM

3000

KPM 100-200
KPC 100-400

6000

9000

KPM 300

KPM 400

You might also like