You are on page 1of 16

Hydraulic pipes

Hydraulic pipes

Edition: 02/2008

Catalogue 2

301

Hydraulic pipes

Note

Information about fitting, installation, pressure loads and permissible operating temperatures can be found in
the technical information for pipe fittings.

All the information in this catalogue is based on the standards applicable at the time of publication and the regulations of the employers liability insurance associations. Product safety can only be guaranteed if our assembly
instructions are followed correctly. Failure to follow any of these instructions may affect the operational safety
of the product and invalidate our warranty. Our warranty in any event only covers HANSA-FLEX products. Our
products are constantly being updated, technical modifications are possible.
While we take every care in editing and checking the catalogue we cannot rule out possible errors or omissions
and accept no liability for the information it contains.

2008 HANSA-FLEX Hydraulik GmbH www.hansa-flex.com

302

Catalogue 2

Edition: 02/2008

Hydraulic pipes

Pipes

Metric precision steel pipes

PR

Metric precision steel pipe


Standard: DIN EN 10305-4
Material: Steel ST 37.4 NBK (1.0255)
Surface protection: phosphate treated and oiled
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 235 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 225 (N/mm2)
Tolerances: DIN 10305-4

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation
PR 04-0,5
PR 04-0,75
PR 05-0,75
PR 06-0,75
PR 04-1
PR 05-1
PR 06-1
PR 08-1
PR 10-1
PR 12-1
PR 14-1
PR 15-1
PR 16-1
PR 18-1
PR 22-1
PR 25-1
PR 06-1,5
PR 08-1,5
PR 10-1,5
PR 12-1,5
PR 14-1,5
PR 15-1,5
PR 16-1,5
PR 18-1,5
PR 20-1,5
PR 22-1,5
PR 25-1,5
PR 28-1,5
PR 32-1,5
PR 06-2
PR 08-2
PR 10-2

d2
mm
4
4
5
6
4
5
6
8
10
12
14
15
16
18
22
25
6
8
10
12
14
15
16
18
20
22
25
28
32
6
8
10

d1
mm
3,0
2,5
3,5
4,5
2,0
3,0
4,0
6,0
8,0
10,0
12,0
13,0
14,0
16,0
20,0
23,0
3,0
5,0
7,0
9,0
11,0
12,0
13,0
15,0
17,0
19,0
22,0
25,0
29,0
2,0
4,0
6,0

S
mm
0,50
0,75
0,75
0,75
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
2,00
2,00
2,00

I
static
bar
210
405
325
286
603
482
416
320
263
219
187
175
164
146
119
105
663
516
407
344
299
279
262
233
209
190
167
149
131
924
693
554

III
dynamic
bar
189
345
282
251
484
400
352
278
232
196
169
159
149
133
109
97
524
424
345
297
262
246
231
207
188
172
152
136
120
683
543
451

Nominal pressure
DIN ISO 10763
bar
259
423
321
259
624
460
365
259
201
164
139
129
120
106
86
75
624
423
321
259
217
201
187
164
146
132
115
102
89
989
624
460

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

Edition: 02/2008

Catalogue 2

303

Hydraulic pipes

Pipes

Metric precision steel pipes

PR

Metric precision steel pipe


Standard: DIN EN 10305-4
Material: Steel ST 37.4 NBK (1.0255)
Surface protection: phosphate treated and oiled
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 235 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 225 (N/mm2)
Tolerances: DIN 10305-4

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation

PR 12-2
PR 14-2
PR 15-2
PR 16-2
PR 18-2
PR 20-2
PR 22-2
PR 25-2
PR 28-2
PR 30-2
PR 35-2
PR 42-2
PR 06-2,25
PR 08-2,5
PR 10-2,5
PR 12-2,5
PR 14-2,5
PR 15-2,5
PR 16-2,5
PR 18-2,5
PR 20-2,5
PR 22-2,5
PR 25-2,5
PR 28-2,5
PR 30-2,5
PR 35-2,5
PR 38-2,5
PR 10-3
PR 12-3
PR 14-3
PR 15-3
PR 16-3

d2
mm
12
14
15
16
18
20
22
25
28
30
35
42
6
8
10
12
14
15
16
18
20
22
25
28
30
35
38
10
12
14
15
16

d1
mm
8,0
10,0
11,0
12,0
14,0
16,0
18,0
21,0
24,0
26,0
31,0
38,0
1,5
3,0
5,0
7,0
9,0
10,0
11,0
13,0
15,0
17,0
20,0
23,0
25,0
30,0
33,0
4,0
6,0
8,0
9,0
10,0

S
mm
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,25
2,50
2,50
2,50
2,50
2,50
2,50
2,50
2,50
2,50
2,50
2,50
2,50
2,50
2,50
3,00
3,00
3,00
3,00
3,00

I
static
bar
469
407
380
346
320
288
262
230
205
192
152
119
1053
888
711
592
514
480
450
395
355
333
293
261
244
196
181
867
723
619
578
542

III
dynamic
bar
391
345
324
298
278
252
231
205
184
173
138
109
755
663
555
477
423
398
377
335
305
288
256
231
217
177
163
650
562
495
467
442

Nominal pressure
DIN ISO 10763
bar
365
303
279
259
226
201
181
157
139
129
109
90
1248
883
624
485
398
365
337
293
259
232
201
177
164
139
127
825
624
504
460
423

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

304

Catalogue 2

Edition: 02/2008

Hydraulic pipes

Pipes

Metric precision steel pipes

PR

Metric precision steel pipe


Standard: DIN EN 10305-4
Material: Steel ST 37.4 NBK (1.0255)
Surface protection: phosphate treated and oiled
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 235 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 225 (N/mm2)
Tolerances: DIN 10305-4

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation
PR 18-3
PR 20-3
PR 22-3
PR 25-3
PR 28-3
PR 30-3
PR 35-3
PR 38-3
PR 42-3
PR 60-3
PR 14-3,5
PR 20-3,5
PR 25-3,5
PR 12-4
PR 16-4
PR 20-4
PR 25-4
PR 28-4
PR 30-4
PR 35-4
PR 38-4
PR 42-4
PR 50-4
PR 60-4
PR 25-4,5
PR 28-4,5
PR 25-5
PR 28-5
PR 30-5
PR 35-5
PR 38-5
PR 42-5

d2
mm
18
20
22
25
28
30
35
38
42
60
14
20
25
12
16
20
25
28
30
35
38
42
50
60
25
28
25
28
30
35
38
42

d1
mm
12,0
14,0
16,0
19,0
22,0
24,0
29,0
32,0
36,0
54,0
7,0
13,0
18,0
4,0
8,0
12,0
17,0
20,0
22,0
27,0
30,0
34,0
42,0
52,0
16,0
19,0
15,0
18,0
20,0
25,0
28,0
32,0

S
mm
3,00
3,00
3,00
3,00
3,00
3,00
3,00
3,00
3,00
3,00
3,50
3,50
3,50
4,00
4,00
4,00
4,00
4,00
4,00
4,00
4,00
4,00
4,00
4,00
4,50
4,50
5,00
5,00
5,00
5,00
5,00
5,00

I
static
bar
482
433
394
347
309
289
241
222
193
130
731
512
409
984
738
590
472
421
393
331
305
268
225
182
535
477
597
533
489
420
387
343

III
dynamic
bar
400
364
335
299
270
253
214
198
174
119
568
421
347
717
572
475
393
355
334
286
266
236
201
165
437
396
480
436
411
355
330
296

Nominal pressure
DIN ISO 10763
bar
365
321
287
247
217
201
169
155
139
365
624
388
296
989
624
460
347
303
279
234
213
190
157
95
402
349
460
398
365
303
275
245

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

Edition: 02/2008

Catalogue 2

305

Hydraulic pipes

Pipes

Metric precision steel pipes

PR

Metric precision steel pipe


Standard: DIN EN 10305-4
Material: Steel ST 37.4 NBK (1.0255)
Surface protection: phosphate treated and oiled
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 235 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 225 (N/mm2)
Tolerances: DIN 10305-4

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation
PR 50-5
PR 38-6
PR 50-6
PR 38-7
PR 65-8
PR 60-10
PR 80-10

d2
mm
50
38
50
38
65
60
80

d1
mm
40,0
26,0
38,0
24,0
49,0
40,0
60,0

S
mm
5,00
6,00
6,00
7,00
8,00
10,00
10,00

I
static
bar
288
469
350
552
356
496
346

III
dynamic
bar
252
391
302
449
306
410
312

Nominal pressure
DIN ISO 10763
bar
201
342
247
414
254
129
259

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

306

Catalogue 2

Edition: 02/2008

Hydraulic pipes

Pipes

Metric precision steel pipes

PR VZ

Metric precision steel pipe


Standard: DIN EN 10305-4
Material: Steel ST 37.4 NBK (1.0255)
Surface protection: electro galvanised,
yellow chromized
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 235 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 225 (N/mm2)
Tolerances: DIN 10305-4

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation
PR 05-0,75 VZ
PR 06-0,75 VZ
PR 04-1 VZ
PR 05-1 VZ
PR 06-1 VZ
PR 08-1 VZ
PR 10-1 VZ
PR 12-1 VZ
PR 15-1 VZ
PR 18-1 VZ
PR 06-1,5 VZ
PR 08-1,5 VZ
PR 10-1,5 VZ
PR 12-1,5 VZ
PR 14-1,5 VZ
PR 15-1,5 VZ
PR 16-1,5 VZ
PR 18-1,5 VZ
PR 20-1,5 VZ
PR 22-1,5 VZ
PR 28-1,5 VZ
PR 08-2 VZ
PR 10-2 VZ
PR 12-2 VZ
PR 14-2 VZ
PR 15-2 VZ
PR 16-2 VZ
PR 18-2 VZ
PR 20-2 VZ
PR 22-2 VZ
PR 25-2 VZ
PR 28-2 VZ

d2
mm
4
6
4
5
6
8
10
12
15
18
6
8
10
12
14
15
16
18
20
22
28
8
10
12
14
15
16
18
20
22
25
28

d1
mm
2,5
4,5
2,0
3,0
4,0
6,0
8,0
10,0
13,0
16,0
3,0
5,0
7,0
9,0
11,0
12,0
13,0
15,0
17,0
19,0
25,0
4,0
6,0
8,0
10,0
11,0
12,0
14,0
16,0
18,0
21,0
24,0

S
mm
0,75
0,75
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00

I
static
bar
325
286
602
482
416
320
263
219
175
146
663
516
407
344
299
279
262
233
209
190
149
693
554
469
407
380
346
320
288
262
230
205

III
dynamic
bar
282
251
484
400
352
278
232
196
159
133
524
424
345
297
262
246
231
207
188
172
136
543
451
391
345
324
298
278
252
231
205
184

Nominal pressure
DIN ISO 10763
bar
321
259
624
460
365
259
201
164
129
106
624
423
321
259
217
201
187
164
146
132
102
624
460
365
303
279
259
226
201
181
157
139

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

Edition: 02/2008

Catalogue 2

307

Hydraulic pipes

Pipes

Metric precision steel pipes

PR VZ

Metric precision steel pipe


Standard: DIN EN 10305-4
Material: Steel ST 37.4 NBK (1.0255)
Surface protection: electro galvanised,
yellow chromized
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 235 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 225 (N/mm2)
Tolerances: DIN 10305-4

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
d2
mm

d1
mm

S
mm

I
static
bar

III
dynamic
bar

Nominal pressure
DIN ISO 10763
bar

PR 35-2 VZ

35

31,0

2,00

152

138

109

PR 42-2 VZ

42

38,0

2,00

119

109

90

PR 10-2,5 VZ

10

5,0

2,50

711

555

624

PR 12-2,5 VZ

12

7,0

2,50

592

477

485

PR 14-2,5 VZ

14

9,0

2,50

514

423

398

PR 16-2,5 VZ

16

11,0

2,50

450

377

337

PR 18-2,5 VZ

18

13,0

2,50

395

335

293

PR 20-2,5 VZ

20

15,0

2,50

355

305

259

PR 22-2,5 VZ

22

17,0

2,50

333

288

232

PR 25-2,5 VZ

25

20,0

2,50

293

256

201

PR 28-2,5 VZ

28

23,0

2,50

261

231

177

PR 30-2,5 VZ

20

25,0

2,50

244

217

164

PR 38-2,5 VZ

38

23,0

2,50

181

163

127

PR 20-3 VZ

20

14,0

3,00

433

364

321

PR 25-3 VZ

25

19,0

3,00

347

299

247

PR 28-3 VZ

28

22,0

3,00

270

309

217

PR 30-3 VZ

30

24,0

3,00

289

253

201

PR 35-3 VZ

35

29,0

3,00

241

214

169

PR 38-3 VZ

38

32,0

3,00

222

198

155

PR 42-3 VZ

42

36,0

3,00

193

174

139

PR 30-4 VZ

30

22,0

4,00

393

334

279

PR 35-4 VZ

35

27,0

4,00

331

286

234

PR 38-4 VZ

38

30,0

4,00

305

266

213

PR 38-5 VZ

38

28,0

5,00

387

330

275

PR 38-6 VZ

38

26,0

6,00

469

391

342

Designation

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

308

Catalogue 2

Edition: 02/2008

Hydraulic pipes

Pipes

Metric precision steel pipes

PR V1

Precision steel pipe, metric


Material: Stainless steel 1.4301
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 218 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 175 (N/mm2)
Tolerances: DIN 10305-5
Creep limit according to DIN 10216-5 Rp 1,0 up to 50 C.
The permanent fatigue strength has been reduced
according to the Material characteristic value by 1,4571.

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
d2
mm

d1
mm

S
mm

I
static
bar

III
dynamic
bar

Nominal pressure
up to 100 C
bar

Nominal pressure
at 200 C
bar

PR 08-1,5 V 1

1,5

460

319

182

149

PR 12-1,5 V 1

12

1,5

307

223

111

91

PR 16-2 V 1

16

12

2,0

321

232

111

91

PR 20-2 V 1

20

16

2,0

257

189

86

71

PR 40-5 V 1

40

30

5,0

337

243

111

91

Designation

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

Edition: 02/2008

Catalogue 2

309

Hydraulic pipes

Pipes

Metric precision steel pipes

PR V2

Metric precision steel pipe


Material: Stainless steel 1.4541
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 222 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 180 (N/mm2)
Tolerances: DIN 10305-5
Creep limit according to DIN 10216-5 Rp 1,0 up to 50 C.
The permanent fatigue strength has been reduced
according to the Material characteristic value by 1,4571.

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation

PR 12,7-0,91 V 2
PR 04-1 V 2
PR 06-1 V 2
PR 08-1 V 2
PR 10-1 V 2
PR 12-1 V 2
PR 14-1 V 2
PR 15-1 V 2
PR 16-1 V 2
PR 18-1 V 2
PR 20-1 V 2
PR 22-1 V 2
PR 28-1 V 2
PR 08-1,5 V 2
PR 10-1,5 V 2
PR 12-1,5 V 2
PR 15-1,5 V 2
PR 16-1,5 V 2
PR 18-1,5 V 2
PR 20-1,5 V 2
PR 22-1,5 V 2
PR 23-1,5 V 2
PR 30-1,5 V 2
PR 32-1,5 V 2
PR 35-1,5 V 2
PR 40-1,5 V 2
PR 10-2 V 2
PR 12-2 V 2
PR 14-2 V 2
PR 15-2 V 2

d2
mm
12,7
4,0
6,0
8,0
10,0
12,0
14,0
15,0
16,0
18,0
20,0
22,0
28,0
8,0
10,0
12,0
15,0
16,0
18,0
20,0
22,0
23,0
30,0
32,0
35,0
40,0
10,0
12,0
14,0
15,0

d1
mm
10,88
2,00
4,00
6,00
8,00
10,00
12,00
13,00
14,00
16,00
18,00
20,00
26,00
5,00
7,00
9,00
12,00
13,00
15,00
17,00
19,00
20,00
27,00
29,00
32,00
37,00
6,00
8,00
10,00
11,00

S
mm
0,91
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,00
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
1,50
2,00
2,00
2,00
2,00

I
static
bar
158
567
379
284
227
189
162
165
155
138
124
113
88
469
375
313
250
234
220
187
180
163
132
110
101
87
523
436
374
349

III
dynamic
bar
121
387
272
210
171
144
125
127
119
107
96
88
69
328
270
229
187
176
166
143
137
125
102
86
79
69
360
308
269
253

Nominal pressure Nominal pressure


up to 100 C
at 200 C
bar
bar
68
61
305
272
178
159
127
113
98
88
80
72
68
61
63
56
59
52
52
46
46
41
42
37
33
29
207
184
157
140
127
113
98
88
91
81
80
72
80
72
65
58
61
55
46
41
43
39
39
35
34
31
225
200
178
159
148
132
136
122

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

310

Catalogue 2

Edition: 02/2008

Hydraulic pipes

Pipes

Metric precision steel pipes

PR V2

Metric precision steel pipe


Material: Stainless steel 1.4541
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 222 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 180 (N/mm2)
Tolerances: DIN 10305-5
Creep limit according to DIN 10216-5 Rp 1,0 up to 50 C.
The permanent fatigue strength has been reduced
according to the Material characteristic value by 1,4571.

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation
PR 16-2 V 2
PR 18-2 V 2
PR 20-2 V 2
PR 22-2 V 2
PR 25-2 V 2
PR 28-2 V 2
PR 30-2 V 2
PR 32-2 V 2
PR 34-2 V 2
PR 38-2 V 2
PR 42-2 V 2
PR 54-2 V 2
PR 60,3-2 V 2
PR 76,1-2 V 2
PR 25-2,5 V 2
PR 18-2,5 V 2
PR 28-2,5 V 2
PR 26,9-2,6 V 2
PR 48,3-2,6 V 2
PR 20-3 V 2
PR 25-3 V 2
PR 28-3 V 2
PR 30-3 V 2
PR 38-3 V 2
PR 26,9-3,2 V 2
PR 30-4 V 2

d2
mm
16,0
18,0
20,0
22,0
25,0
28,0
30,0
32,0
34,0
38,0
42,0
54,0
60,3
76,1
25,0
18,0
28,0
26,9
48,3
20,0
25,0
28,0
30,0
38,0
26,9
30,0

d1
mm
12,00
14,00
16,00
18,00
21,00
24,00
26,00
28,00
30,00
34,00
38,00
50,00
56,30
72,10
20,00
13,00
23,00
21,70
43,10
14,00
19,00
22,00
24,00
32,00
20,50
22,00

S
mm
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,00
2,50
2,50
2,50
2,60
2,60
3,00
3,00
3,00
3,00
3,00
3,20
4,00

I
static
bar
327
302
261
238
217
194
181
157
147
102
112
82
78
62
277
373
247
268
134
420
336
292
273
210
326
371

III
dynamic
bar
239
222
195
178
164
147
138
121
114
132
88
64
62
49
205
268
185
199
104
298
244
216
202
159
238
267

Nominal pressure
up to 100 C
bar
127
111
98
88
77
68
63
59
55
49
44
34
30
24
98
143
87
95
50
157
121
106
98
76
12
136

Nominal pressure
at 200 C
bar
113
99
88
79
68
61
56
52
49
44
39
30
27
21
88
128
77
84
45
140
108
95
88
67
107
122

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

Edition: 02/2008

Catalogue 2

311

Hydraulic pipes

Pipes

Metric precision steel pipes

PR V4

Metric precision steel pipe


Material: Stainless steel 1.4571
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 234 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 190 (N/mm2)
Tolerances: DIN 10305-05
Creep limit according to DIN 10216-5 Rp 1,0 up to 50 C.

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation

PR 04-1 V 4
PR 06-1 V 4
PR 08-1 V 4
PR 10-1 V 4
PR 12-1 V 4
PR 15-1 V 4
PR 18-1 V 4
PR 06-1,5 V 4
PR 08-1,5 V 4
PR 10-1,5 V 4
PR 12-1,5 V 4
PR 14-1,5 V 4
PR 15-1,5 V 4
PR 16-1,5 V 4
PR 18-1,5 V 4
PR 22-1,5 V 4
PR 25-1,5 V 4
PR 28-1,5 V 4
PR 33,7-1,6 V 4
PR 48,3-1,6 V 4
PR 08-2 V 4
PR 10-2 V 4
PR 12-2 V 4
PR 14-2 V 4
PR 15-2 V 4
PR 16-2 V 4
PR 18-2 V 4
PR 20-2 V 4
PR 21,3-2 V 4
PR 22-2 V 4
PR 25-2 V 4
PR 28-2 V 4

d2
mm
4,0
6,0
8,0
10,0
12,0
15,0
18,0
6,0
8,0
10,0
12,0
14,0
158,0
16,0
18,0
22,0
25,0
28,0
33,7
48,3
8,0
10,0
12,0
14,0
15,0
16,0
18,0
20,0
21,3
22,0
25,0
28,0

d1
mm
2,0
4,0
6,0
8,0
10,0
13,0
16,0
3,0
5,0
7,0
9,0
11,0
12,0
13,0
15,0
19,0
22,0
25,0
30,5
45,1
4,0
6,0
8,0
10,0
11,0
12,0
14,0
16,0
17,3
18,0
21,0
24,0

S
mm
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,6
1,6
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0

I
static
bar
600
400
300
240
200
174
145
660
495
396
330
283
264
261
232
190
167
149
126
77
690
552
460
394
368
345
318
287
269
260
229
205

III
dynamic
bar
408
287
222
181
152
134
112
442
347
285
242
210
197
195
175
145
128
115
98
32
458
380
325
284
267
252
234
213
201
195
173
156

Nominal pressure
up to 100 C
bar
321
188
133
103
84
66
54
321
217
165
133
112
103
96
84
68
59
52
46
32
321
236
188
156
143
133
116
103
96
93
81
71

Nominal pressure
at 200 C
bar
289
169
120
93
76
60
49
289
196
149
120
101
93
87
76
61
53
47
42
29
289
213
169
140
129
120
105
93
87
84
73
64

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

312

Catalogue 2

Edition: 02/2008

Hydraulic pipes

Pipes

Metric precision steel pipes

PR V4

Metric precision steel pipe


Material: Stainless steel 1.4571
Item description:
Analogue calculation DIN 2413 (draft)
Loading I: static stress
Loading III: stress intensity factor range P = bar
Material characteristic value: K 234 (N/mm2)
Safety factor: S 1,5
Permanent fatigue strength: Sch/D 190 (N/mm2)
Tolerances: DIN 10305-05
Creep limit according to DIN 10216-5 Rp 1,0 up to 50 C.

Note: The stated pressure designation refers to a straight tube.


For bent tubes the respective wall thickness has be calculated analogically to DIN 2413 or DIN EN 13480-4.
Designation
PR 30-2 V 4
PR 35-2 V 4
PR 42-2 V 4
PR 42,4-2 V 4
PR 17,2-2,3 V 4
PR 14-2,5 V 4
PR 16-2,5 V 4
PR 18-2,5 V 4
PR 20-2,5 V 4
PR 22-2,5 V 4
PR 25-2,5 V 4
PR 28-2,5 V 4
PR 30-2,5 V 4
PR 35-2,5 V 4
PR 42,4-2,6 V 4
PR 60,3-2,9 V 4
PR 76,1-2,9 V 4
PR 88,9-2,9 V 4
PR 12-3 V 4
PR 16-3 V 4
PR 20-3 V 4
PR 22-3 V 4
PR 25-3 V 4
PR 30-3 V 4
PR 42-3 V 4
PR 33,7-3,2 V 4
PR 48,3-3,2 V 4
PR 42,4-3,2 V 4
PR 88,9-3,2 V 4
PR 114,3-3,2 V 4
PR 30-4 V 4
PR 38-4 V 4
PR 38-5 V 4

d2
mm
30,0
36,0
42,0
42,4
17,2
14,0
16,0
18,0
20,0
22,0
25,0
28,0
30,0
35,0
42,4
60,3
76,1
88,9
12,0
16,0
20,0
22,0
25,0
30,
42,0
33,7
48,3
42,4
88,9
114,3
30,0
38,0
38,0

d1
mm
26,0
32,0
38,4
38,4
12,6
9,0
11,0
13,0
15,0
17,0
20,0
23,0
25,0
30,0
37,2
54,5
70,3
83,1
6,0
10,0
14,0
16,0
19,0
26,0
36,0
27,3
41,9
36
82,5
107,9
22,0
30,0
28,0

S
mm
2,0
2,0
2,0
2,0
2,3
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,6
2,9
2,9
2,9
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,2
3,2
3,2
3,2
3,2
4,0
4,0
5,0

I
static
bar
191
151
118
117
375
505
442
393
345
321
292
260
243
196
161
121
90
71
694
540
432
392
345
288
193
274
180
206
82
54
392
303
385

III
dynamic
bar
146
117
92
92
272
353
314
283
258
236
216
195
183
149
124
95
71
57
461
373
308
283
252
214
147
205
138
156
65
43
282
224
278

Nominal pressure
up to 100 C
bar
66
56
46
46
144
204
173
151
133
119
103
91
84
71
61
47
37
31
321
217
165
147
127
103
71
97
66
76
35
27
143
109
141

Nominal pressure
at 200 C
bar
60
51
42
41
130
184
156
136
120
108
93
82
76
64
55
42
33
28
289
196
149
133
115
93
64
88
59
68
31
24
129
99
127

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

Edition: 02/2008

Catalogue 2

313

Hydraulic pipes

Pipes

French precision steel pipes

PR franzoesisch

French precision steel pipe


Material: Steel ST 37.4 NBK (1.0255)
Surface protection: electro galvanised,
yellow chromized

Item description: Calculation as in DIN ISO 10763 (DIN handbook 174 Page 416)
Temperature range: -20 C to +120 C
Load: Kinetic (dynamic load)
Safety: 4 : 1
Designation

d2
mm

d1
mm

S
mm

Nominal pressure
bar

PR 13
PR 17

13,25

8,75

2,25

374

16,75

11,25

2,75

358

PR 21

21,25

14,75

3,25

329

PR 27

26,75

20,25

3,25

251

PR 33

33,5

25,4

4,05

249

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure


L = Pipe length approx. 6 metres

314

Catalogue 2

Edition: 02/2008

Hydraulic pipes

Pipe bends

Angle 90

RB

Pipe bend 90
Standard: DIN 2391/C
Material: Steel ST 37.4 NBK (1.0255)
Surface protection: phosphate treated and
oiled

Item description: Seamless pipe bend 90 for minimum loss of flow

Designation

mm

S
mm

Internal
mm

Bending radius R
mm

a
mm

b
mm

L1
mm

L2
mm

RB 14-1,5

14

1,5

11

30

200

40

230

70

RB 15-1,5

15

1,5

12

30

200

40

230

70

RB 15-2

15

2,0

11

30

200

40

230

70

RB 16-2

16

2,0

12

30

200

40

230

70

RB 18-1,5

18

1,5

15

36

200

35

236

71

RB 18-2

18

2,0

14

36

200

35

236

72

RB 20-2

20

2,0

16

36

200

45

236

81

RB 20-2,5

20

2,5

15

36

200

45

236

81

RB 20-3

20

3,0

14

36

200

45

236

81

RB 22-1,5

22

1,5

19

38

200

40

238

78

RB 22-2

22

2,0

18

38

200

40

238

78

RB 22-2,5

22

2,5

17

38

200

40

238

78

RB 22-3,5

22

3,5

15

38

200

40

238

78

RB 25-2

25

2,0

21

44

200

50

244

94

RB 25-2,5

25

2,5

20

44

200

50

244

94

RB 25-3

25

3,0

19

44

200

50

244

94

RB 25-4

25

4,0

17

44

200

50

244

94

RB 28-1,5

28

1,5

25

48

200

50

248

98

RB 28-2

28

2,0

24

48

200

50

248

98

RB 28-3

28

3,0

22

48

200

50

248

98

RB 30-2,5

30

2,5

25

50

200

60

250

110

RB 30-3

30

3,0

24

50

200

60

250

110

RB 30-4

30

4,0

22

50

200

60

250

110

RB 35-2

35

2,0

31

60

200

65

260

125

RB 35-3

35

3,0

29

60

200

65

260

125

RB 38-2,5

38

2,5

33

65

200

75

265

140

RB 38-3

38

3,0

32

65

200

75

265

140

RB 38-4

38

4,0

30

65

200

75

265

140

RB 38-5

38

5,0

28

65

200

75

265

140

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure

Edition: 02/2008

Catalogue 2

315

Hydraulic pipes

Pipe bends

Angle 90

RB

Pipe bend 90
Standard: DIN 2391/C
Material: Steel ST 37.4 NBK (1.0255)
Surface protection: phosphate treated and
oiled

Item description: Seamless pipe bend 90 for minimum loss of flow

Designation

mm

S
mm

Internal
mm

Bending radius R
mm

a
mm

b
mm

L1
mm

L2
mm

RB 42-2

42

2,0

38

80

200

85

280

165

RB 42-3

42

3,0

36

80

200

85

280

165

RB 50-6

50

6,0

38

210

100

100

310

310

RB 65-8

65

8,0

49

210

110

110

320

320

RB 80-10

80

10,0

60

210

120

120

330

330

= External pipe diameter PN = Nominal pressure PB = Max. operating pressure

316

Catalogue 2

Edition: 02/2008

You might also like