The cathode ray is a beam of electrons which are emitted by the heated cathode (negative electrode) and
accelerated toward the fluorescent screen. The assembly of the cathode, intensity grid, focus grid, and accelerating
anode (positive electrode) is called an electron gun. Its purpose is to generate the electron beam and control its
intensity and focus. Between the electron gun and the fluorescent screen are two pair of metal plates - one oriented
to provide horizontal deflection of the beam and one pair oriented ot give vertical deflection to the beam. These
plates are thus referred to as the horizontal and vertical deflection plates. The combination of these two deflections
allows the beam to reach any portion of the fluorescent screen. Wherever the electron beam hits the screen, the
phosphor is excited and light is emitted from that point. This coversion of electron energy into light allows us to
write with points or lines of light on an otherwise darkened screen.
In the most common use of the oscilloscope the signal to be studied is first amplified and then applied to the
vertical (deflection) plates to deflect the beam vertically and at the same time a voltage that increases linearly with
time is applied to the horizontal (deflection) plates thus causing the beam to be deflected horizontally at a uniform
(constant> rate. The signal applied to the verical plates is thus displayed on the screen as a function of time. The
horizontal axis serves as a uniform time scale.
The linear deflection or sweep of the beam horizontally is accomplished by use of a sweep generator that is
incorporated in the oscilloscope circuitry. The voltage output of such a generator is that of a sawtooth wave as
shown in Fig. 2. Application of one cycle of this voltage difference, which increases linearly with time, to the
horizontal plates causes the beam to be deflected linearly with time across the tube face. When the voltage suddenly
falls to zero, as at points (a) (b) (c), etc...., the end of each sweep - the beam flies back to its initial position. The
horizontal deflection of the beam is repeated periodically, the frequency of this periodicity is adjustable by external
controls.
To obtain steady traces on the tube face, an internal number of cycles of the unknown signal that is applied to
the vertical plates must be associated with each cycle of the sweep generator. Thus, with such a matching of
synchronization of the two deflections, the pattern on the tube face repeats itself and hence appears to remain
stationary. The persistance of vision in the human eye and of the glow of the fluorescent screen aids in producing a
stationary pattern. In addition, the electron beam is cut off (blanked) during flyback so that the retrace sweep is not
observed.
CRO Operation: A simplified block diagram of a typical oscilloscope is shown in Fig. 3. In general, the instrument
is operated in the following manner. The signal to be displayed is amplified by the vertical amplifier and applied to
the verical deflection plates of the CRT. A portion of the signal in the vertical amplifier is applied to the sweep
trigger as a triggering signal. The sweep trigger then generates a pulse coincident with a selected point in the cycle
of the triggering signal. This pulse turns on the sweep generator, initiating the sawtooth wave form. The sawtooth
wave is amplified by the horizontal amplifier and applied to the horizontal deflection plates. Usually, additional
provisions signal are made for appliying an external triggering signal or utilizing the 60 Hz line for triggering. Also
the sweep generator may be bypassed and an external signal applied directly to the horizontal amplifier.
Cro Description:Display and general external appearance
The basic oscilloscope, as shown in the illustration, is typically divided into four sections: the display,
vertical controls, horizontal controls and trigger controls.
The display is usually a CRT or LCD panel which is laid out with both horizontal and vertical reference
lines referred to as the graticule. In addition to the screen, most display sections are equipped with three
basic controls, a focus knob, an intensity knob and a beam finder button.
The vertical section controls the amplitude of the displayed signal. This section carries a Volts-perDivision (Volts/Div) selector knob, an AC/DC/Ground selector switch and the vertical (primary) input for
the instrument. Additionally, this section is typically equipped with the vertical beam position knob.
The horizontal section controls the time base or sweep of the instrument. The primary control is the
Seconds-per-Division (Sec/Div) selector switch. Also included is a horizontal input for plotting dual X-Y
axis signals. The horizontal beam position knob is generally located in this section.
The trigger section controls the start event of the sweep. The trigger can be set to automatically restart
after each sweep or it can be configured to respond to an internal or external event. The principal controls
of this section will be the source and coupling selector switches. An external trigger input (EXT Input) and
level adjustment will also be included.
CRO Controls
The controls available on most oscilloscopes provide a wide range of operating conditions and thus make the
instrument especially versatile. Since many of these controls are common to most oscilloscopes a brief description
of them follows.
CATHODE-RAY TUBE
Power and Scale Illumination: Turns instrument on and controls illumination of the graticule.
Focus: Focus the spot or trace on the screen.
Intensity: Regulates the brightness of the spot or trace.
Bandwidth
Bandwidth is a measure of the range of frequencies that can be displayed; it refers primarily to the vertical
amplifier, although the horizontal deflection amplifier has to be fast enough to handle the fastest sweeps.
The bandwidth of the oscilloscope is limited by the vertical amplifiers and the CRT (in analog instruments)
or by the sampling rate of the analog to digital converter in digital instruments. The bandwidth is defined
as the frequency at which the sensitivity is 0.707 of the sensitivity at lower frequency (a drop of 3 dB).
The rise time of the fastest pulse that can be resolved by the scope is related to its bandwidth
approximately:
Bandwidth in Hz x rise time in seconds = 0.35
For example, an oscilloscope intended to resolve pulses with a rise time of 1 nanosecond would have a
bandwidth of 350 MHz.
For a digital oscilloscope, a rule of thumb is that the continuous sampling rate should be ten times the
highest frequency desired to resolve; for example a 20 megasample/second rate would be applicable for
measuring signals up to about 2 megahertz.
WARNING: Never advance the Intensity Control so far that an excessively bright spot appears. Bright spots imply
burning of the screen. A sharp focused spot of high intensity (great brightness) should never be allowed to remain
fixed in one position on the screen for any length of time as damage to the screen may occur.
Adjust Horizontal and Vertical Centering Controls. Adjust the focus to give a sharp trace. Set trigger to internal,
level to auto.
PROCEDURE:
I. Set the signal generator to a frequency of 1000 cycles per second. Connect the output from the gererator to the
vertical input of the oscilloscope. Establish a steady trace of this input signal on the scope. Adjust (play with)all of
the scope and signal generator controls until you become familiar with the functionof each. The purpose fo such
"playing" is to allow the student to become so familiar with the oscilloscope that it becomes an aid (tool) in making
measurements in other experiments and not as a formidable obstacle. Note: If the vertical gain is set too low, it may
not be possible to obtain a steady trace.
II. Measurement
s of
Voltage: Consid
er the circuit in
Fig. 4(a). The
signal generator
is used to
produce a 1000
hertz sine wave.
The AC
voltmeter and
the leads to the
verticle input of
the oscilloscope
are connected
across the
generator's
output. By
adjusting the
Horizontal Sweep time/cm and trigger, a steady trace of the sine wave may be displayed on the screen. The trace
represents a plot of voltage vs. time, where the vertical deflection of the trace about the line of symmetry CD is
proportional to the magnitude of the voltage at any instant of time.
To determine the size of the voltage signal appearing at the output of terminals of the signal generator, an AC
(Alternating Current) voltmeter is connected in parallel across these terminals (Fig. 4a). The AC voltmeter is
designed to read the dc "effective value" of the voltage. This effective value is also known as the "Root Mean Square
value" (RMS) value of the voltage.
The peak or maximum voltage seen on the scope face (Fig. 4b) is Vm volts and is represented by the distance
from the symmetry line CD to the maximum deflection. The relationship between the magnitude of the peak voltage
displayed on the scope and the effective or RMS voltage (VRMS) read on the AC voltmeter is
VRMS = 0.707 Vm (for a sine or cosine wave).
Thus
Agreement is expected between the voltage reading of the multimeter and that of the oscilloscope. For a
symmetric wave (sine or cosine) the value of Vm may be taken as 1/2 the peak to peak signal Vpp
The variable sensitivity control a signal may be used to adjust the display to fill a concenient range of the scope face.
In this position, the trace is no longer calibrated so that you can not just read the size of the signal by counting the
number of divisions and multiplying by the scale factor. However, you can figure out what the new calibration is an
use it as long as the variable control remains unchanged.
Caution: The mathematical prescription given for RMS signals is valid only for sinusoidal signals. The meter will
not indicate the correct voltage when used to measure non-sinusoidal signals.
III. Frequency Measurements: When the horizontal sweep voltage is applied, voltage measurements can still be
taken from the vertical deflection. Moreover, the signal is displayed as a function of time. If the time base (i.e.
sweep) is calibrated, such measurements as pulse duration or signal period can be made. Frequencies can then be
determined as reciprocal of the periods.
Set the oscillator to 1000 Hz. Display the signal on the CRO and measure the period of the oscillations. Use
the horizontal distance between two points such as C to D in Fig. 4b.
Set the horizontal gain so that only one complete wave form is displayed.
Then reset the horizontal until 5 waves are seen. Keep the time base control in a calibrated position. Measure
the distance (and hence time) for 5 complete cycles and calculate the frequency from this measurement. Compare
you result with the value determined above.
Repeat your measurements for other frequencies of 150 Hz, 5 kHz, 50 kHz as set on the signal generator.
IV. Lissajous Figures: When sine-wave signals of different frequencies are input to the horizontal and vertical
amplifiers a stationary pattern is formed on the CRT when the ratio of the two frequencies is an intergral fraction
such as 1/2, 2/3, 4/3, 1/5, etc. These stationary patterns are known as Lissajous figures and can be used for
comparison measurement of frequencies.
Use two oscillators to generate some simple Lissajous figures like those shown in Fig. 5. You will find it
difficult to maintain the Lissajous figures in a fixed configuration because the two oscillators are not phase and
frequency locked. Their frequencies and phase drift slowly causing the two different signals to change slightly with
respect to each other.
V. Testing what you have learned: Your instructor will provide you with a small oscillator circuit. Examine the input
to the circuit and output of the circuit using your oscilloscope. Measure such quantities as the voltage and frequence
of the signals. Specify if they are sinusoidal or of some other wave character. If square wave, measure the frequency
of the wave. Also, for square waves, measure the on time (when the voltage is high) and off time (when it is low).
Examples of use:-
Lissajous figures on an oscilloscope, with 90 degrees phase difference between x and y inputs.
One of the most frequent uses of scopes is troubleshooting malfunctioning electronic equipment. One of the
advantages of a scope is that it can graphically show signals: where a voltmeter may show a totally unexpected
voltage, a scope may reveal that the circuit is oscillating. In other cases the precise shape or timing of a pulse is
important.
In a piece of electronic equipment, for example, the connections between stages (e.g. electronic mixers, electronic
oscillators, amplifiers) may be 'probed' for the expected signal, using the scope as a simple signal tracer. If the
expected signal is absent or incorrect, some preceding stage of the electronics is not operating correctly. Since most
failures occur because of a single faulty component, each measurement can prove that half of the stages of a
complex piece of equipment either work, or probably did not cause the fault.
Once the faulty stage is found, further probing can usually tell a skilled technician exactly which component has
failed. Once the component is replaced, the unit can be restored to service, or at least the next fault can be isolated.
This sort of troubleshooting is typical of radio and TV receivers, as well as audio amplifiers, but can apply to quitedifferent devices such as electronic motor drives.
Another use is to check newly designed circuitry. Very often a newly designed circuit will misbehave because of
design errors, bad voltage levels, electrical noise etc. Digital electronics usually operate from a clock, so a dual-trace
scope which shows both the clock signal and a test signal dependent upon the clock is useful. Storage scopes are
helpful for "capturing" rare electronic events that cause defective operation.
Function generator
Definition:- A function generator is usually a piece of electronic test equipment or software used to generate
different types of electrical waveforms over a wide range of frequencies. Some of the most common waveforms
produced by the function generator are the sine, square, triangular and sawtooth shapes. These waveforms can be
either repetitive or single-shot (which requires an internal or external trigger source). Integrated circuits used to
generate waveforms may also be described as function generator ICs.
Feature:- Other important features of the function generator are continuous tuning over wide bands with max-min
A typical function generator can provide frequencies up to 20 MHz. RF generators for higher frequencies are not
function generators in the strict sense since they typically produce pure or modulated sine signals only.
Function generators, like most signal generators, may also contain an attenuator, various means of modulating the
output waveform, and often the ability to automatically and repetitively "sweep" the frequency of the output
waveform (by means of a voltage-controlled oscillator) between two operator-determined limits. This capability
makes it very easy to evaluate the frequency response of a given electronic circuit.
Some function generators can also generate white or pink noise.
More advanced function generators are called arbitrary waveform generators (AWG). They use direct digital
synthesis (DDS) techniques to generate any waveform that can be described by a table of amplitudes.
Specifications
Typical specifications for a general-purpose function generator are:
Produces sine, square, triangular, sawtooth (ramp), and pulse output. Arbitrary waveform generators can
produce waves of any shape.
It can generate a wide range of frequencies. For example, the Tektronix FG 502 (ca 1974) covers 0.1 Hz to
11 MHz.
Frequency stability of 0.1 percent per hour for analog generators or 500ppm for a digital generator.
Maximum sinewave distortion of about 1% (accuracy of diode shaping network) for analog
generators. Arbitrary waveform generators may have distortion less than -55dB below 50 kHz and less than
-40dB above 50 kHz.
Some function generators can be phase locked to an external signal source, which may be a frequency
reference or another function generator.
Amplitude can be modified, usually by a calibrated attenuator with decade steps and continuous adjustment
within each decade.
Some generators provide a DC offset voltage, e.g. adjustable between -5V to +5V.
generators can be completely separate from the generator and are typically large enough to stand upon their
own. These units may also be shelf-mounted or wall-mounted next to the
generator, which is common inside an enclosure or intental application like a data
center.
Control panels are usually fitted with buttons or switches that help to operate the
generator such as a switch-off button or turn-on key. The switches and gauges are
usually grouped on the basis of functionality. This makes the panel friendly and
safe for use since it minimizes the possibility of an operator accidentally selecting
or executing the wrong control. Imagine trying to shut down a vibrating generator with a spring loaded lever in
the middle of the night and you will appreciate why having a simple cut of switch at the control panel makes
sense.
The front panel is divided into six major control groups:
1) Frequency Selection Group;
2) Sweep Group;
3) Amplitude Modulation Group;
4) DC Offset Group;
5) Function, or Waveform Group; and
6) Output Group.
The attenuation buttons are used to attenuate (decrease) the amplitude of the signal by a factor measured in
decibels. The following relationship will assist in working with the attenuation buttons:
(dB) = -10 * log10 (Pout / Pin) (if power is the unit of measurement) or
(dB) = -20 * log10(Vout / Vin) (if voltage is the unit of measurement)
(3) Function/Waveform Selection Group:- This group is used to select the shape of the generated waveform.
The group is made up of the six wave-selector buttons. The six waveforms that the function generator can
produce are the sine wave, the square wave, the triangle wave, two sawtooth waves, and the variable-width
pulse wave.