You are on page 1of 4

dchRcLostT

long
long
long
long

,
,
,
,

Range
Range
Range
Range

[0....100
[0....100
[0....100
[0....100

(18000)]
(18000)]
(18000)]
(18000)]

,
,
,
,

Default
Default
Default
Default

:
:
:
:

50
50
50
50

,
,
,
,

P5_RNC
P6_RNC
P6FP_RNC
P7ED_RNC

Timer that is started when all radio links for a connection are lost. At time-out, the radio
connection is considered lost.
Special values:
The value 18000 deci seconds = 1800 s = 30 minutes is used for testing purposes to
"disable"
the Radio Connection Supervision functionality for a UE on dedicated channels.
Unit: 0.1 s
Resolution: 5
Change takes effect: The value CANNOT be changed for an ongoing connection; that is,
whenever the attribute is reconfigured in the RNC, the new value shall only apply to new
connections.

RADIO CONNECTION SUPERVISION EVALUATION


This algorithm keeps track of the synchronization status of the radio connection by assigning
a tag to every RLS. Upon creation of a new RLS the tag is set to "Fail". The tag is shifted to
"OK" upon reception of a RL restore indication and then to "Fail" upon reception of a RL
failure indication. If all RLSs are tagged as "Fail" and the timer dchRcLostT has expired,
then the radio connection shall be considered lost and the overall release of the connection is
triggered as shown in Figure 4-11.

hsDschRcLostT

long , Range [0....600 (18000)] , Default : 100 , P5_RNC


long , Range [0....600 (18000)] , Default : 50 , P6_RNC
long , Range [0....600 (18000)] , Default : 50 , P6FP_RNC
long , Range [0....600 (18000)] , Default : 50 , P7ED_RNC
Controls the RCS timer for supervision of uplink synch of RLS containing the serving
HSDSCH
radio link.
Special values:

18000 indicates that the RCS function is switched off. Used for test purposes.
Unit: 0.1 s Resolution: 5

Where HSDPA connections are concerned, the radio connection shall be considered
unsynchronized when the RLS that contains the Serving HS-DSCH RL is unsynchronized. A
timer, hsdDchRcLostT, shall be started when that RLS is considered unsynchronized. If the
RLS is unsynchronized during hsDschRcLostT and the timer expires, the signaling
connection is released.
For HS users, only the RL in the serving HS-DSCH cell is supervised. Also, a separate
parameter, hsdschRcLostT, determines how long time a HS user can be out-of-sync before
the connection is released..
Since the synchronization state is relative only to the link set containing the HS-DSCH, the
synchronization status may change with a serving HS-DSCH cell change.

tRrcActiveSetUpdate
#################################################
#################################
MO Class
Attribute
Type
Flags
#################################################
#################################
RncSystemParameters
tRrcActiveSetUpdate
long
EricssonOnly
----------------------------------------------------------------------------------------------------------------------------------Timer used to supervise the RRC Active Set Update procedure.
Started at transmission of RRC ACTIVE SET UPDATE REQUEST.
Stopped at reception of RRC ACTIVE SET UPDATE COMPLETE or RRC ACTIVE SET
UPDATE FAILURE.

Unit: s
This attribute may only be changed by Ericsson personnel.
Range: 1 to 30, Default=5
**********************************************************************************
**************************************************

tRrcChSwitch3
#################################################
#################################
MO Class
Attribute
Type
Flags
#################################################
#################################
RncSystemParameters
tRrcChSwitch3
long
EricssonOnly
----------------------------------------------------------------------------------------------------------------------------------Started at transmission of RRC: TRANSPORT CHANNEL RECONFIGURATION or
RADIO BEARER RECONFIGURATION.
Stopped at reception of RRC: TRANSPORT CHANNEL RECONFIGURATION
COMPLETE or RADIO BEARER RECONFIGURATION COMPLETE.
Unit: s
This attribute may only be changed by Ericsson personnel.
Range: 1 to 30, Default=5
**********************************************************************************

tRrcRABEst
#################################################
#################################
MO Class
Attribute
Type
Flags
#################################################
#################################
RncSystemParameters
tRrcRABEst
long
EricssonOnly
----------------------------------------------------------------------------------------------------------------------------------Waiting time for RRC RESPONSE.
Unit: s
This attribute may only be changed by Ericsson personnel.
Range: 1 to 30, Default=5
**********************************************************************************

t313:
T313 Out-of-Sync Reception Timer
3GPP TS 25.331 8.5.6 states that after receiving N313 consecutive "out of sync" indications from
layer 1 (see N313 Successive Out-Of-Sync Reception Max ), the UE shall start the T313 timer. Upon
receiving N315 successive "in sync" indications from layer 1 ( N315 Successive In-Sync Reception
Counter ), the UE shall stop and reset the T313 timer. If T313 expires, a "Radio Link failure" has
occurred, and the UE shall drop the call.