You are on page 1of 13

Product Change Notice

Huawei PCN SRAN-2012XXXX (EOM Notice on


DBS3900(AC) APM30H&TMC11H&IBBS200D&T Ver.B
cabinets)

1. Abstract
The Ver.B cabinets and internal parts will be in the end of marketing (EOM). The DBS3900 (AC) Ver.D
cabinets will be sold to replace the Ver.B cabinets. This PCN is intended for customers using Huawei
DBS3900 (AC) Ver.B cabinets.
The last date for purchase of the Ver.B cabinets is June 30, 2013 and the last date for supply of Ver.B
cabinet is December 31, 2013.

1. Supplier Information
Huawei Technologies. Co., Ltd.

Confidential

Page 1 of 13

Product Change Notice

2. Basic Information
PCN No.

SRAN-2012XXXX

PCN Version

Rev: 01

Change Category

B
Official release of

Release

the PCN
GA

Implementation

Milestone

Production

of

No order accepted
for Ver.B cabinet

December 31, 2012

June 30, 2013

No delivery after

December 31, 2013, from which no old cabinets will

EOP

be delivered (the delivery time in new sales contracts

for

Ver.B

cabinet
No

End of Service

new

cabinets

End of Marketing

End

of

July 15, 2012

provided

should not be later than this date)


service
after

Subject to the specific contract

EOS

3. Involved Systems and Products


There are two types for APM30H/ TMC11H but only one type for IBBS200D/T in Ver.D cabinets.
Customer can select one type to replace the current version of cabinets.
Main System

DBS3900 (AC) Ver.D1


DBS3900 (AC) Ver.D2

Subsystem

Cabinets and internal parts

Hardwar

Softwar

Firmwar

Plug-in

Yes

No

No

No

Yes

Yes

No

No

note1

Note 1 To replace Ver.B cabinets with the same maximum configuration of 6 RRU, the Ver.D1/Ver.D2
cabinets can work normal with the same BTS software version. But if the enhanced configuration of Ver.D2
need be used like supporting 12 RRU, the BTS software version should be upgraded.

Confidential

Page 2 of 13

Product Change Notice

4. Correlated Change
N/A

5. BOM Code Change


New

BOM

Board Name

Code

Old

BOM

Board Name

Complete Replacement

Code

Ver.D1

APM30H cabinet

Ver.B

APM30H cabinet

Yes

Ver.D2

APM30H cabinet

Ver.B

APM30H cabinet

Yes

Ver.D

IBBS200D cabinet

Ver.B

IBBS200D cabinet

Yes

Ver.D

IBBS200T cabinet

Ver.B

IBBS200T cabinet

Yes

Ver.D1

TMC11H cabinet

Ver.B

TMC11H cabinet

Yes

Ver.D2

TMC11H cabinet

Ver.B

TMC11H cabinet

Yes

01071382

EPU05A-03

02400460

EPS 01B

No (Note 1)

01071384

EPU05A-05

02400462

EPS 01D

No (Note 1)

02310HBJ

R4850G

02130608

EPW30-48A

No (Note 1)

02310LYP

PMU 11A

02317275

PMU 01B

No (Note 1)

02120734

FAN 02D

02120559

FAN 02A

No (Note 1)

03021VGY

CMUEA

03020NXE

CMUA

No (Note 1)

02120732

DCDU-12C

02120479

DCDU-03C

No (Note 1)

21161105

TEC module

21161003

TEC module

No (Note 1)

32030092

The external fan of Heat


Exchanger of
APM30H/TMC11H

32030077

The external fan of Heat


Exchanger of
APM30H/TMC11H

No (Note 1)

Confidential

97051086

Page 3 of 13

Product Change Notice

New

BOM

Board Name

Code

Old

BOM

Board Name

Complete Replacement

Code
Ver.D1/Ver.D2 cabinet

Ver.B cabinet

Note 1 The spare parts of the Ver.D cabinet are different from the Ver.B cabinets. Therefore, a certain
quantity of spare parts of the Ver.B cabinets must be reserved for future use. The last order date of spare parts
is June 30, 2015 for Ver.B cabinets.

6. Categorization Basis
(1) Ver.B cabinets and parts will be in the EOM and be replaced by Ver.D..
(2) The new release has all the functions of current version and better performance. The Ver.B can support 6
RRU(2*40W) at maximum. The Ver.D1 can support 6 RRU(2*60W) at maximum. The Ver.D2 supports
6 RRU(2*60W) at maximum without BTS software upgrading. The Ver.D2 also supports 12
RRU(2*60W) with one DCDU-12B added at 1U user space in APM30H after BTS software is upgraded.
The Ver.D2 cabinet supports two BBU in one APM30H also.

7. Change Description
(A) The change of the Ver. D cabinets
The changed parts include the Heat Exchanger, fan tray, TEC and DCDU.etc. The external size and
installing of new cabinet are the same as old one.
The Ver.D cabinet improves the capacity of power supply, heat dissipation and cabling. It has all the
functions of the Ver.B cabinet and better performance instead.
The cabinet version info can be acquired by OMC remotely or be seen on the nameplate in the cabinet
on site.
(B) The major changed parts from Ver.B to Ver.D cabinet

Confidential

Page 4 of 13

Product Change Notice

7.1
The change of Heat Exchanger and interal Fan tray in APM30H
and TMC11H

(A) The air vent areas are enlarged for the internal heat exchanger on the door of APM30H/TMC11H
Ver.D1/Ver.D2 cabinet. But the external size of the door keeps the same as the Ver.B still.
The external fan type and Heat exchanger core are changed from Ver.B cabinet to Ver.D1/Ver.D2
cabinet. The external fan type is the same between APM30H/TMC11H Ver.D1 and
APM30H/TMC11H Ver.D2.

Confidential

Page 5 of 13

Product Change Notice

(B) The fan tray is changed from FAN 02A to FAN 02D. The air outlet position is changed from top to
bottom.
The HPMI board is cancelled to make the monitor cable connection simple on the new fan tray. The
GATE andTEM_BAT1interfaces are supported directly in PMU11A module for APM30H. The
other internal reserved interfaces are cancelled to avoid wrong connection.

(C) The heat dissipation capacity of APM30H/TMC11H is improved.


Heat dissipation

Cabinet version
APM30H/TMC11H Ver.B

700W
<=700W

APM30H/TMC11H Ver.D1
>700W and <=1050W
<=700W
APM30H/TMC11H Ver.D2
>700W and <=1500W

Confidential

Acoustic noise
ETS 300 753, Rural area, Class
4.1E(6.1bels@25, 6.7bels@45)
ETS 300 753, Rural area, Class
4.1E(6.1bels@25, 6.7bels@45)
ETS 300 753, Urban area, Class
4.1E(6.6bels@25, 7.6bels@45)
ETS 300 753, Rural area, Class
4.1E(6.1bels@25, 6.7bels@45)
ETS 300 753, Urban area, Class
4.1E(6.6bels@25, 7.6bels@45)

Page 6 of 13

Product Change Notice

7.2

The change of AC/DC power system inside in APM30H

(A) The layout and name change.


When Ver.D1/Ver.D2 APM30H cabinet replace the Ver.B cabinet, the EPU05A-03 (220V AC) or
EPU05A-05 (110V AC) replace the EPS 01B (220V AC) or EPS 01D (110V AC) of embedded
power system.
APM30H Ver.D1 supports 3 PSU at maximum. APM30H Ver.D2 supports 5 PSU at maximum.
Three PSU can be managed in Ver.D2 cabinet like Ver.B cabinet with the same BTS software. The
BTS software need be upgraded if four or five PSU need be used in Ver.D2 cabinet to support 12
RRU.

(B) The change of PSU


version

name

Ver.B

EPW30-

Power capacity
1600W/PCS

48A
Ver.D1/Ver.D

R4850G

3000W/PCS

2
Ver.B

PMU 01B

--

Ver.D1/Ver.D
2

PMU 11A

--

The highest efficiency


91%

96%
---

Remark: The height is 1U only for PSU and PMU in new version cabinet. The old PSU and PMU
are 2U high.

Confidential

Page 7 of 13

Product Change Notice

(C) The change of AC power distribution

AC Input Breaker
3(1P MCB) PSU

AC Input Breaker
240A+125A (1P MCB) PSU

AC Output Breaker
1(2P MCB) Heater/Socket

AC Output Breaker
116A (2P MCB) Heater/Socket

220V input EPS 01B

220V input EPU05A-03

AC Input Breaker
1(2P MCB) PSU

AC Input Breaker
1100A(2P MCB) PSU

AC Output Breaker
1(1P MCB) Heater
1(1P MCB) Socket

AC Output Breaker
116A (1P MCB) Heater
116A (1P MCB) Socket

110V dual phase input EPS 01D

110V dual phase input EPU05A-05

(D) The change of DC power distribution

LLVD
620A(1P MCB) RRU
BLVD
215A(FUSE) BBU
115A(FUSE) FAN
45A(FUSE) TM
1 (1P MCB ) TMC
115A(FUSE) TEC
1100A (1P MCB) BATT

LLVD
630A(FUSE) RRU
1125A(1P MCB) RFC
BLVD
230A(FUSE) BBU
130A(FUSE) FAN
430A(FUSE) TM
1 (FUSE ) TMC
130A(FUSE) IBBS
1125A (2P MCB) BATT

Remark: The spare fuses are changed from 2*5A+6*15A to 5*5A+3*30A in APM30H cabinet.

Confidential

Page 8 of 13

Product Change Notice

(E) The change of AC power interface from customer


Only when the Ver.D cabinet has more powerful RF configurations than Ver.B, the power interface
should be changed.
Input voltage

220Vac three
phase

Ver.B,
Ver.D1,
Ver.D2

6 x RRU(2*40W)

Ver.D1,
Ver.D2

6 x RRU(2*60W)

Ver.D2

220Vac single
phase
Or 110Vac duallive-wire

7.3

RFU types and


configuration

Cabinet
version

Ver.B,
Ver.D1,
Ver.D2

AC power interface from customer

25A/3P (2.5 mm2 cables)minimum.

25A/3P (4 mm2 cables)minimum.

12 RRU(2*60W)

40A/3P (6 mm2 cables) minimum.

6 x RRU(2*40W)

Ver.D1,
Ver.D2

6 x RRU(2*60W)

Ver.D2

12 RRU(2*60W)

50A/2P, (6 mm2 cables)minimum.

63A/2P (16 mm2 cables)minimum.


100A/2P (16 mm2 LSZH cables) minimum.

The change of cable outlet in APM30H and TMC11H

The power cable diameter is enlarged and the cable outlet is adjusted also on the bottom of cabinet. The
new outdoor type of cable bag has double space for cable and much shorter installing time than the current
version.

7.4

The change of DCDU in TMC11H

(A) The layout and name change.

(B) The enhance of DC distribution


Version

Confidential

Distribution capacity

Page 9 of 13

Product Change Notice

Ver.B

7x12A1P MCB+2x6A1P MCB

Ver.D

10 x 30A (fuse)

Remark: There are three spare fuses of 30A in the right of new DCDU.
(C) The change of the input connection to support the parallel connection of 2 route 16mm 2 cables.

(D) The change of output connectors to benefit installing. Plugging or unplugging the connector can
power on or off the load of the new version DCDU.

7.5

The change of fan tray in IBBS200D


There is only one fan in IBBS200D Ver.D to save power consumption. The Ver.B has two fans.
The monitor board is changed from CMUA of Ver.B cabinet to CMUEA of Ver.D cabinet. But the

external cable interfaces keeps the same.

7.6

The change of TEC module in IBBS200T


The Thermoelectric Cooler module is changed in IBBS200T Ver.D. The installing interface keeps

the same for the new TEC module.


The monitor board is changed from CMUA of Ver.B cabinet to CMUEA of Ver.D cabinet. But the
external cable interfaces keeps the same.

Confidential

Page 10 of 13

Product Change Notice

7.7

The change of IBBS200D/IBBS200T PDU


The power distribution unit is improved in Ver.D to support more powerful equipments with more

discharge current.

7.8

The change of cable outlet in IBBS200D/IBBS200T

The power cable diameter is enlarged and the cable outlet is adjusted also on the bottom of cabinet. The
new outdoor type of cable bag has double space for cable and much shorter installing time than the current
version.

7.9

The change of all cabinets package

The cabinet external packages are changed from wood to paper in order to be more
environments friendly.

Confidential

Page 11 of 13

Product Change Notice

8. Impact of Change
Security

Fire

Service

Communication

None

None

Yes

None

For Ver.D2 cabinet is configured four or


five PSU to support more than 6 RRU,
the BTS software need be upgraded and
it interrupt service within 5 minutes
No service is impacted if there are three
PSU are used in Ver.D1 and Ver.D2 at
maximum to support 6 RRU
Maintenance

Reliability

Power Consumption

Traffic

Yes.

None

Yes

Yes.

Some spare parts of the

Ver.D cabinet support much more

Ver.D BTS supports

Ver.

powerful RRU with some increased

much higher traffic.

cabinet

are

different from the Ver. B

power consumption.

cabinet.

No

Therefore,

more

power

consumption

is

certain quantity of spare

increased for Ver.D cabinet using the

parts of the Ver. B cabinet

same type and number of BBU and

must be reserved for

RRU modules as Ver.B cabinet.

future use.

9. Involved Documents
The changes will affect the DBS3900 Product description and DBS3900 User Manual.

10. Appendixes
None

Confidential

Page 12 of 13

Product Change Notice

11. Remarks
If you have any questions, contact Huawei local sales representatives or technical support personnel for assistance.

Confidential

Page 13 of 13

You might also like