You are on page 1of 123

R410A 50/60Hz

0CVT0-01A

LG Airconditioners Product Data

(R410A)

Introduction
General Information
Outdoor Units
Installation of Outdoor Units

Introduction
1. Preface
R410A Model
is the most favored choice when there is a need for precise air conditioning of relatively big projects extending from Multi-Room structure to big commercial places. We have a big line up, that offers wider
flexibility of model selection.
Equipped with inverter technology and long piping installation, the product matches well if one talk about optimum power consumption in high rise buildings. Add on capacity feature makes it easy to upgrade the existing
capacity at any time.
With the growing concern about environment preservation,
comes with R410A refrigerant which is
environment friendly and thus our
system is a high technology and environment friendly product.

Unique refrigerant flow and electronic circuit control gives this system an unique capability to work in
extreme/abnormal working conditions making our customer feel great about their decision of selecting
LG
as their first choice.
This publication provides a detailed and in depth information about the design and installation of
We hope that with this information you would become an expert of your

system.

Air-Conditioning Division

Introduction

2. Step by Step
(1)

System Selection Process

Calculate or obtain the maximum heat load for the area(s) to be air conditioned

(2)

Decide the indoor unit specifications


Decide the outdoor unit specifications
Capacity coefficient factor
Decide the air velocity and temperature distributions

(3)

(4)

Selection of refrigerant pipe joints and headers

Selection of the control system


Control wiring method
Description of devices

(5)

Electrical wiring
Electric characteristics
Field wiring

Air conditioners should not be installed in areas where corrosive gases such as acid gas
or alkaline gas is produced.

Introduction

General Information

1. Model Names
2. External Appearance
3. Combination of Outdoor Units
4. Nomenclature
5. Outdoor Units information

General information

1. Model Names
Power Supply

10HP

20HP

30HP

40HP

3, 380~415V, 50Hz
3, 380V, 60Hz

ARWN100LA2

ARWN200LA2

ARWN300LA2

ARWN400LA2

General information

2. External Appearance
10 HP
ARWN100LA2

20 HP
ARWN200LA2

30 HP
ARWN300LA2

40 HP
ARWN400LA2

General information

3. Combination of Outdoor Units


System
Capacity
(HP)

Number of Units

10

20

30

40

General information

Module(HP)
10

20

1
1
1

1
2

4. Nomenclature
ARW

100

Serial Number
A: Basic Function
Electrical Ratings
L: 3, 380 ~ 415V, 50Hz / 3, 380V, 60Hz
Total Cooling Capacity in Horse Power(HP) unit
EX) 10HP'100'
Combination of Inverter Type and
Cooling Only or Heat Pump
N: Inverter and H/P

Indicates that this is


Outdoor Unit using the R410A

System

General information

5. Outdoor Units Information


CAUTION: A ratio of the connectable Indoor Units with the Outdoor: Within 50 ~ 130%
A ratio of the running Indoor Units with the Outdoor: Within 10 ~ 100%
A combinated operation over 100% causes to reduce the total capacity.

Power Supply: Outdoor Unit (3, 380 ~ 415V, 50Hz / 3, 380V, 60Hz)
System Capacity
HP
Model Name
Product Refrigerant Charge
kg
CF(Correction Factor)
kg
Maximum Connectable No. of Indoor Units
kg
Net Weight
lb
mm
Dimensions(WxHxD)
inch
Refrigerant
Liquid
mm(inch)
Connecting Pipes
Gas
mm(inch)
Inlet
Water
Outlet
Connecting Pipes
Drain Outlet

10
ARWN100LA2
7.3
16
(170) x 1
(374.8) x 1
(772 x 1,120 x 547) x 1
(30.4 x 44.1 x 21.5) x 1
9.52(3/8)
22.2(7/8)
PT 32A
PT 32A
PT 20A

20
ARWN200LA2
8.8
32
(238)x1
(524.7)x1
(772 x 1,120 x 547) x 1
(30.4 x 44.1 x 21.5) x 1
12.7(1/2)
28.58(1 1/8)
PT 40A
PT 40A
PT 20A

System Capacity
HP
Model Name
Product Refrigerant Charge
kg
CF(Correction Factor)
kg
Maximum Connectable No. of Indoor Units
kg
Net Weight
lb
mm
Dimensions(WxHxD)
inch
Refrigerant
Liquid
mm(inch)
Connecting Pipes
Gas
mm(inch)
Inlet
Water
Outlet
Connecting Pipes
Drain Outlet

30
ARWN300LA2
7.3+8.8
49
(170) x 1, (238) x 1
(374.8) x 1, (524.7) x 1
(772 x 1,120 x 547) x 2
(30.4 x 44.1 x 21.5) x 2
15.88(5/8)
34.9(1 3/8)
PT32A, PT40A
PT32A, PT40A
PT 20A

40
ARWN400LA2
8.8+8.8
64
(238) x 1, (238) x1
(524.7) x 1, (524.7) x1
(772 x 1,120 x 547) x 2
(30.4 x 44.1 x 21.5) x 2
19.05(3/4)
41.3(1 5/8)
(PT40A)x2
(PT40A)x2
PT 20A

General information

General information

Outdoor Units
1. Specifications
2. Dimensions
3. Piping Diagrams
4. Wiring Diagrams
5. Field Wiring
6. Electric Characteristics
7. Capacity Tables
8. Operation Limits
9. Sound Levels
10. Accessories

Outdoor Units

1. Specifications
Heat Pump(50Hz/60Hz)
System Capacity
Model Name

HP

Cooling
Capacity
Heating
Input

Cooling
Heating

kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kW

Casing Color
Type
Combination
Piston Displacement
Number of revolution
Compressor
Motor Output
Starting Method
Oil Type
Oil Charge Amount
Type
Heat Exchanger Maximum Pressure Loss
Rated Water Flow
Liquid
Refrigerant
Gas
Connecting Pipes
High/Low Pressure Common
Inlet
Water
Outlet
Connecting Pipes
Drain Outlet
Dimensions(WxHxD)
Net Weight
Transmission Cable(CVV-SB)
Name
Refrigerant
Charge Amount
Control Device
Power Supply

cm3/rev
rev/min
kW

cc
kgf/cm2
L/min
mm(inch)
mm(inch)
mm(inch)

mm
inch
kg
lb
mm2
kg
/V/Hz

10
ARWN100LA2
29.0
24,940
98,950
32.6
28,030
111,240
5.8
6.0
Warm Gray
Hermetic Motor Scroll
(Inverter)x1
52.0
3,600 at 60Hz
(5.4)x1
Direct On Line
FVC68D(PVE)
(2,32510)x1
Stainless Steel Plate
43
96
9.52(3/8)
22.2(7/8)
PT 32A
PT 32A
PT 20A
(772x1,120x547)x1
(30.4x44.1x21.5)x1
(170)x1
(374.8)x1
(1.25)x2
R410A
7.3
EEV(Electronic Expansion Valve)
3/380~415/50
3/380/60

20
ARWN200LA2
58
48,200
197,904
65
54,100
211,798
11.6
12.0
Warm Gray
Hermetic Motor Scroll
(Inverter)x1, (Constant)x1
52.0, 81.0
3,600 at 60Hz, 2,891
(5.4)x1 , (6.7)x1
Direct On Line
FVC68D(PVE)
(2,32510)x1, (2,32570)x1
Stainless Steel Plate
43
192
12.7(1/2)
28.85(1 1/8)
PT 40A
PT 40A
PT 20A
(772x1,120x547)x1
(30.4x44.1x21.5)x1
(238)x1
(524.7)x1
(1.25)x2
R410A
8.8
EEV(Electronic Expansion Valve)
3/380~415/50
3/380/60

Notes:
1. Capacities are based on the following conditions
Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB
Water inlet temp. 30C[86F]
Heating : Indoor temp. 20C[68F]DB
Water Inlet temp. 20C[68F]
* Interconnecting Piping Length 7.5m
* Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. Recommend operation temp: Outdoor 0~40 C

Outdoor Units

Heat Pump(50Hz/60Hz)
System Capacity
Model Name

HP

Cooling
Capacity
Heating
Input

Cooling
Heating

kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kW

Casing Color
Type
Combination
Piston Displacement
Number of revolution
Compressor
Motor Output
Starting Method
Oil Type
Oil Charge Amount
Type
Heat Exchanger Maximum Pressure Loss
Rated Water Flow
Liquid
Refrigerant
Gas
Connecting Pipes
High/Low Pressure Common
Inlet
Water
Outlet
Connecting Pipes
Drain Outlet
Dimensions(WxHxD)
Net Weight
Transmission Cable(CVV-SB)
Name
Refrigerant
Charge Amount
Control Device
Power Supply

cm3/rev
rev/min
kW

cc
kgf/cm2
L/min
mm(inch)
mm(inch)
mm(inch)

mm
inch
kg
lb
mm2
kg
/V/Hz

30
ARWN300LA2
87.0
74,800
296,860
97.9
84,180
334,050
17.4
18.1
Warm Gray
Hermetic Motor Scroll
(Inverter)x2, (Constant)x1
52.0, 81.0
3,600 at 60Hz, 2,891
(5.4)x2 , (6.7)x1
Direct On Line
FVC68D(PVE)
(2,32510)x2, (2,32570)x1
Stainless Steel Plate
43
96+192
15.88(5/8)
34.9(1 3/8)
19.05(3/4)
PT32A+PT40A
PT32A+PT40A
PT 20A
(772x1,120x547)x2
(30.4x44.1x21.5)x2
(170)x1, (238)x1
(374.8)x1, (524.7)x1
(1.25)x2
R410A
7.3
EEV(Electronic Expansion Valve)
3/380~415/50
3/380/60

40
ARWN400LA2
116
99,700
395,808
130
118,000
443,578
23.2
24.0
Warm Gray
Hermetic Motor Scroll
(Inverter)x2, (Constant)x2
52.0, 81.0
3,600 at 60Hz, 2,891
(5.4)x2 , (6.7)x2
Direct On Line
FVC68D(PVE)
(2,32510)x2, (2,32570)x2
Stainless Steel Plate
43
192+192
19.05(3/4)
41.3(1 5/8)
19.05(3/4)
PT40A+PT40A
PT40A+PT40A
PT 20A
(772x1,120x547)x2
(30.4x44.1x21.5)x2
(238)x2
(524.7)x2
(1.25)x2
R410A
8.8
EEV(Electronic Expansion Valve)
3/380~415/50
3/380/60

Notes:
1. Capacities are based on the following conditions
Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB
Water inlet temp. 30C[86F]
Heating : Indoor temp. 20C[68F]DB
Water Inlet temp. 20C[68F]
* Interconnecting Piping Length 7.5m
* Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. Recommend operation temp: Outdoor 0~40 C

Outdoor Units

2. Dimensions
ARWN100LA2
ARWN200LA2

Outdoor Units

3. Piping Diagrams
ARWN100LA2
Pressure sensor

INV
: Inverter
Comp. : Compressor
EEV : Electronic Expansion Valve
O/S
: Oil Separator
Accum. : Accumulator
SC HEX: Subcooling Circuit
Heat Exchanger

Pressure switch
Check valve
EEV
Thermistor
S

Solenoid valve
Service valve
Strainer

Water Water
Inlet Outlet
Pipe Pipe

(For Only 30 HP)

s
Outdoor
Air

HIgh

Hot Gas Bypass

Accum

Plate
Heat
Exchanger

Low

O/S

s
Oil return
INV
Comp

Receiver

Liquid
Injection
SC HEX

Liquid Gas High/Low


Pipe Pipe Pressure
Common
Pipe
(19.05mm)

Outdoor Units

ARWN200LA2
Pressure sensor

INV
: Inverter
Comp. : Compressor
EEV : Electronic Expansion Valve
O/S
: Oil Separator
Accum. : Accumulator
SC HEX: Subcooling Circuit
Heat Exchanger

Pressure switch
Check valve
EEV
Thermistor
S

Solenoid valve
Service valve
Strainer

Water Water
Inlet Outlet
Pipe Pipe

(For Only 30 / 40 HP)

s
Outdoor
Air

HIgh

Hot Gas Bypass

Accum

Plate
Heat
Exchanger

Low

O/S

O/S

INV
Comp

Normal
Comp

s
Oil return

Receiver

Liquid
Injection

SC HEX

Liquid Gas High/Low


Pipe Pipe Pressure
Common
Pipe
(19.05mm)

Outdoor Units

4. Wiring Diagrams
ARWN100LA2

Outdoor Units

ARWN200LA2

Outdoor Units

5. Field Wiring
Example Connection of Transmission Cable
3 phase 4 wires power line(R, S, T, N)
Transmission line (3 line): wired remote control
Single phase of power supply line(L, N)

Power supply switch


(switch fuse)

Transmission line (2 shield line): between indoor unit and outdoor unit

3 phase 4 wires
power supply
50Hz 380~415V

Power supply
1 phase 50Hz
220V

WARNING
Indoor unit ground lines are required for preventing electrical shock accident in current leakage,
transmission disorder by noise effect and motor current leakage (without connection to pipe).
Don't install an individual switch or electrical outlet to disconnect each of indoor unit separately from the
power supply.

SODU
B

IDU

INTERNET
B

DRY1 DRY2 GND

12V
Outdoor unit

The GND terminal is a '' terminal for the central controller, not ground line

Outdoor Units

6. Electric Characteristics
Wiring of Main Power Supply and Equipment Capacity
1. Use a separate power supply for the Outdoor Unit and Indoor Unit.
2. The wire size is the minimum value for metal conduit wiring. The power cord size should be 1 rank thicker taking into account the
line voltage drops. Make sure the power-supply voltage does not drop more than 10%.
3. Specific wiring requirements should adhere to the wiring regulations of the region.
4. Power supply cords of parts of appliances for outdoor use should not be lighter than polychloroprene sheathed flexible cord.
5. Don't install an individual switch or electrical outlet to disconnect each of indoor unit separately from the power supply.

WARNING
Follow ordinance of your governmental organization for technical standard related to electrical equipment, wiring regulations and guidance of each electric power company.
Make sure to use specified wires for connections so that no external force is imparted to terminal connections. If connections are not fixed firmly, it may cause heating or fire.
Make sure to use the appropriate type of overcurrent protection switch. Note that generated overcurrent may include
some amount of direct current.

CAUTION
Some installation site may require attachment of an earth leakage breaker. If no earth leakage breaker is installed, it may cause
an electric shock.
Do not use anything other than breaker and fuse with correct capacity. Using fuse and wire or copper wire with too large
capacity may cause a malfunction of unit or fire.

50Hz
Model

Hz

Volts

Voltage-range
Min.:342
Max.:456
Min.:342
Max.:456
Min.:342
Max.:456
Min.:342
Max.:456

ARWN100LA2

50

380~415

ARWN200LA2

50

380~415

ARWN300LA2

50

380~415

ARWN400LA2

50

380~415

Hz

Volts

Voltage-range
Min.:342
Max.:418
Min.:342
Max.:418
Min.:342
Max.:418
Min.:342
Max.:418

MCA

Compressor

MOP
MSC

RLA

15.1

26.4

20.2

30.1

53.4

-/61

20.2/11.6

43.4

77.3

-/-/61

20.2/20.2/11.6

59.3

105.9

-/61/-/61

20.2/11.6/20.2/11.6

MCA

MOP

60Hz
Model

Compressor
MSC

ARWN100LA2

60

380

ARWN200LA2

60

380

ARWN300LA2

60

380

ARWN400LA2

60

380

RLA

15.1

26.4

20.2

30.1

53.4

-/61

20.2/11.6

43.4

77.3

-/-/61

20.2/20.2/11.6

59.3

105.9

-/61/-/61

20.2/11.6/20.2/11.6

Outdoor Units

Notes:
1. Voltage range
Voltage supplied to the unit terminals should be within the minimum and maximum range
2. Maximum allowable voltage unbalance between phase is 2 %
3. MCA / MOP
MCA = (1.25 x Load1) + Load2
MOP = (2.25 x Load1) + Load2
- Load1 : Rated running current of largest motor
(Compressor or other motor)
- Load2 : any other load rated 1.0A or more
4. Select wire spec. based on the MCA
5. Select proper circuit breaker as given below
MCA < Selected circuit breaker MOP
6. Recommended circuit breaker is ELCB (Earth Leakage Circuit
Breaker)
7. MSC & RLA are measured as the compressor only test condition.
8. MSC values
-/61 : MSC of (INV. Comp) / (Const. Comp.1)

Outdoor Units

9. RLA is measured during each individual compressor test condition.


20.2/11.6 : RLA of (INV. Comp) / (Const. Comp.1)
(Example)
Selection of proper circuit breaker
10HP- Rated running current : 11.3 A
MCA = (1.25 x Load1) + Load2
= (1.25 x 11.3) + 1 = 15.1 A
MOP = (2.25 x Load1) + Load2
= (2.25 x 11.3) + 1 = 26.4 A
Finally select circuit breaker 20A
MCA : Minimum Circuit Amperes (A)
MOP : Maximum rating Over current Protective device
MSC : Maximum Starting Current
RLA : Rated Load Amperes (A)

10

7. Capacity Tables
7.1 Cooling capacity
Cooling Capacity

ARWN100LA2
Indoor Air Temp.(CWB)

14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

130
30

35

40

15

20

25

120
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

26.5
26.5
26.5
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
23.5
23.5
23.5
20.9
20.9
20.9
25.2
25.2
25.2
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
22.8
22.8
22.8
20.7
20.7
20.7

2.71
2.49
2.42
3.29
3.02
2.94
4.05
3.73
3.62
4.86
4.47
4.35
4.92
4.52
4.40
5.19
4.77
4.64
2.59
2.38
2.32
3.16
2.91
2.83
3.88
3.57
3.47
4.69
4.32
4.20
4.81
4.43
4.30
5.18
4.76
4.63

22.8
19.1
18.3
27.9
24.1
23.3
33.0
29.2
28.3
38.3
34.3
33.4
42.6
39.0
38.2
47.0
43.7
42.9
22.5
18.9
18.1
27.5
23.9
23.1
32.7
29.0
28.2
37.9
34.1
33.3
42.4
38.9
38.1
47.0
43.6
42.9

TC:Total Capacity(kW)
PI :Power Input(kW)

11

28.7
28.7
28.7
28.3
28.3
28.3
28.3
28.3
28.3
28.3
28.3
28.3
25.5
25.5
25.5
22.6
22.6
22.6
27.3
27.3
27.3
27.0
27.0
27.0
27.0
27.0
27.0
27.0
27.0
27.0
24.7
24.7
24.7
22.4
22.4
22.4

3.18
2.97
2.91
3.85
3.60
3.53
4.75
4.44
4.35
5.70
5.33
5.22
5.77
5.39
5.28
6.08
5.69
5.57
3.04
2.84
2.78
3.71
3.46
3.39
4.55
4.26
4.17
5.51
5.15
5.04
5.64
5.28
5.16
6.07
5.68
5.56

23.5
19.4
18.5
28.5
24.4
23.6
33.7
29.5
28.6
38.9
34.7
33.7
43.3
39.3
38.4
47.6
44.0
43.2
23.1
19.2
18.4
28.2
24.2
23.4
33.3
29.3
28.5
38.5
34.4
33.6
43.0
39.2
38.3
47.5
43.9
43.1

31.3
31.3
31.3
30.8
30.8
30.8
30.8
30.8
30.8
30.8
30.8
30.8
27.7
27.7
27.7
24.7
24.7
24.7
29.7
29.7
29.7
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
26.9
26.9
26.9
24.4
24.4
24.4

3.70
3.46
3.39
4.49
4.20
4.11
5.54
5.18
5.07
6.64
6.21
6.08
6.72
6.28
6.15
7.09
6.63
6.49
3.54
3.31
3.24
4.32
4.04
3.95
5.30
4.96
4.86
6.41
6.00
5.87
6.57
6.15
6.02
7.08
6.62
6.48

24.3
19.8
18.9
29.3
24.8
23.9
29.3
29.9
28.9
39.7
35.1
34.1
44.0
39.7
38.8
48.3
44.3
43.5
23.8
19.6
18.7
28.9
24.6
23.7
28.9
29.7
28.8
39.3
34.8
33.9
43.7
39.6
38.6
48.2
44.3
43.4

34.0
34.0
34.0
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
30.2
30.2
30.2
26.8
26.8
26.8
32.3
32.3
32.3
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
29.3
29.3
29.3
26.6
26.6
26.6

4.17
3.90
3.82
5.05
4.73
4.63
6.23
5.83
5.71
7.48
6.99
6.86
7.56
7.07
6.93
7.98
7.46
7.31
3.99
3.73
3.66
4.86
4.54
4.46
5.97
5.59
5.48
7.22
6.75
6.62
7.40
6.92
6.79
7.97
7.45
7.30

25.1
20.2
19.2
30.1
25.3
24.2
35.3
30.4
29.3
40.6
35.5
34.4
44.8
40.1
39.1
49.0
44.7
43.8
24.6
20.0
19.0
29.7
25.0
24.0
34.8
30.1
29.1
40.1
35.3
34.2
44.5
40.0
39.0
48.9
44.7
43.7

35.0
35.0
35.0
34.5
34.5
34.5
34.5
34.5
34.5
34.5
34.5
34.5
31.1
31.1
31.1
27.6
27.6
27.6
33.3
33.3
33.3
33.0
33.0
33.0
33.0
33.0
33.0
33.0
33.0
33.0
30.2
30.2
30.2
27.4
27.4
27.4

4.27
4.00
3.92
5.17
4.84
4.75
6.38
5.97
5.86
7.66
7.17
7.03
7.75
7.25
7.11
8.17
7.65
7.50
4.08
3.82
3.75
4.98
4.66
4.57
6.12
5.72
5.62
7.40
6.92
6.79
7.58
7.09
6.96
8.16
7.63
7.49

25.4
20.4
19.3
30.4
25.4
24.3
35.6
30.5
29.4
40.9
35.7
34.5
45.1
40.3
39.2
49.3
44.8
43.9
24.9
20.1
19.1
29.9
25.2
24.1
35.1
30.3
29.2
40.4
35.4
34.3
44.8
40.1
39.1
49.2
44.8
43.8

36.4
36.4
36.4
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
32.3
32.3
32.3
28.7
28.7
28.7
34.6
34.6
34.6
34.2
34.2
34.2
34.2
34.2
34.2
34.2
34.2
34.2
31.3
31.3
31.3
28.4
28.4
28.4

4.38
4.10
4.02
5.30
4.97
4.87
6.54
6.13
6.01
7.85
7.36
7.21
7.94
7.44
7.30
8.37
7.85
7.70
4.18
3.92
3.85
5.10
4.78
4.69
6.27
5.87
5.76
7.58
7.10
6.96
7.77
7.28
7.14
8.36
7.83
7.68

25.8
20.6
19.5
30.8
25.6
24.5
36.0
30.7
29.6
41.3
35.9
34.7
45.5
40.5
39.4
49.6
45.0
44.0
25.2
20.3
19.3
30.3
25.4
24.3
35.5
30.5
29.4
40.8
35.6
34.5
45.2
40.3
39.2
49.6
45.0
44.0

37.4
37.4
37.4
36.9
36.9
36.9
36.9
36.9
36.9
36.9
36.9
36.9
33.2
33.2
33.2
29.5
29.5
29.5
35.6
35.6
35.6
35.2
35.2
35.2
35.2
35.2
35.2
35.2
35.2
35.2
32.2
32.2
32.2
29.2
29.2
29.2

4.45
4.18
4.09
5.40
5.07
4.96
6.66
6.26
6.11
7.99
7.51
7.34
8.08
7.59
7.42
8.52
8.01
7.83
4.26
4.00
3.90
5.19
4.87
4.76
6.38
5.99
5.85
7.71
7.24
7.07
7.91
7.42
7.24
8.51
7.98
7.79

26.1
20.8
19.6
31.1
25.8
24.6
36.3
30.9
29.7
41.6
36.1
34.9
45.8
40.6
39.5
49.9
45.2
44.1
25.5
20.5
19.4
30.6
25.5
24.4
35.8
30.6
29.5
41.1
35.8
34.6
45.5
40.4
39.4
49.8
45.1
44.1

Combi. : Combination
Temp. : Temperature

Outdoor Units

Cooling Capacity
Indoor Air Temp. (CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

110
30

35

40

15

20

25

100
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

23.9
23.9
23.9
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
22.2
22.2
22.2
20.5
20.5
20.5
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
21.5
21.5
21.5
20.4
20.4
20.4

2.47
2.28
2.21
3.03
2.79
2.71
3.71
3.42
3.32
4.53
4.16
4.05
4.71
4.33
4.21
5.17
4.76
4.62
2.36
2.17
2.11
2.91
2.67
2.60
3.54
3.26
3.17
4.36
4.01
3.90
4.60
4.23
4.12
5.16
4.75
4.62

22.1
18.7
17.9
27.2
23.7
23.0
32.3
28.8
28.0
37.5
33.9
33.1
42.2
38.7
38.0
46.9
43.6
42.9
21.7
18.5
17.8
26.8
23.6
22.8
32.0
28.6
27.9
37.1
33.7
33.0
42.0
38.6
37.9
46.8
43.6
42.9

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

25.9
25.9
25.9
25.8
25.8
25.8
25.8
25.8
25.8
25.8
25.8
25.8
24.0
24.0
24.0
22.2
22.2
22.2
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
23.3
23.3
23.3
22.0
22.0
22.0

2.90
2.71
2.66
3.56
3.33
3.25
4.36
4.07
3.99
5.31
4.97
4.86
5.52
5.16
5.05
6.07
5.67
5.55
2.76
2.58
2.53
3.41
3.19
3.12
4.16
3.89
3.80
5.11
4.78
4.68
5.40
5.05
4.94
6.06
5.66
5.54

22.7
19.0
18.2
27.8
24.0
23.2
32.9
29.1
28.3
38.1
34.2
33.4
42.8
39.1
38.2
47.5
43.9
43.1
22.2
18.8
18.0
27.4
23.8
23.1
32.5
28.9
28.1
37.7
34.0
33.2
42.6
38.9
38.1
47.4
43.9
43.1

28.2
28.2
28.2
28.1
28.1
28.1
28.1
28.1
28.1
28.1
28.1
28.1
26.1
26.1
26.1
24.2
24.2
24.2
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
25.3
25.3
25.3
24.0
24.0
24.0

3.38
3.16
3.10
4.14
3.87
3.79
5.07
4.74
4.65
6.19
5.78
5.66
6.43
6.01
5.89
7.06
6.61
6.47
3.22
3.01
2.95
3.97
3.71
3.64
4.84
4.53
4.44
5.96
5.57
5.46
6.29
5.88
5.76
7.05
6.60
6.46

23.3
19.3
18.5
28.5
24.4
23.5
28.5
29.5
28.6
38.9
34.6
33.7
43.5
39.4
38.5
48.1
44.2
43.4
22.9
19.1
18.3
28.0
24.2
23.4
28.0
29.3
28.4
38.4
34.4
33.5
43.2
39.3
38.4
48.1
44.2
43.4

30.7
30.7
30.7
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
28.4
28.4
28.4
26.3
26.3
26.3
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
27.6
27.6
27.6
26.1
26.1
26.1

3.81
3.56
3.49
4.67
4.36
4.28
5.71
5.34
5.24
6.97
6.51
6.39
7.24
6.77
6.64
7.96
7.44
7.29
3.63
3.39
3.32
4.47
4.18
4.10
5.45
5.10
5.00
6.71
6.27
6.15
7.08
6.62
6.49
7.94
7.43
7.28

24.1
19.7
18.8
29.2
24.8
23.8
34.4
29.9
28.9
39.6
35.0
34.0
44.2
39.8
38.8
48.9
44.6
43.7
23.6
19.5
18.6
28.7
24.6
23.6
33.9
29.6
28.7
39.2
34.8
33.8
43.9
39.7
38.7
48.8
44.6
43.7

31.6
31.6
31.6
31.4
31.4
31.4
31.4
31.4
31.4
31.4
31.4
31.4
29.3
29.3
29.3
27.1
27.1
27.1
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
28.4
28.4
28.4
26.9
26.9
26.9

3.90
3.65
3.58
4.78
4.47
4.39
5.85
5.47
5.37
7.13
6.67
6.55
7.41
6.94
6.81
8.15
7.62
7.48
3.71
3.47
3.41
4.58
4.28
4.20
5.58
5.22
5.12
6.87
6.42
6.30
7.25
6.78
6.65
8.13
7.60
7.46

24.3
19.9
18.9
29.5
24.9
23.9
34.7
30.0
29.0
39.9
35.2
34.1
44.5
39.9
39.0
49.1
44.7
43.8
23.8
19.6
18.7
29.0
24.7
23.8
34.2
29.8
28.8
39.4
34.9
33.9
44.2
39.8
38.8
49.0
44.7
43.8

32.8
32.8
32.8
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
30.4
30.4
30.4
28.2
28.2
28.2
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
29.5
29.5
29.5
27.9
27.9
27.9

3.99
3.74
3.67
4.89
4.58
4.50
5.99
5.61
5.51
7.31
6.84
6.71
7.60
7.12
6.98
8.35
7.82
7.67
3.80
3.56
3.49
4.69
4.39
4.31
5.72
5.35
5.25
7.04
6.59
6.46
7.43
6.95
6.82
8.33
7.80
7.65

24.7
20.1
19.0
29.8
25.1
24.1
35.0
30.2
29.2
40.3
35.4
34.3
44.9
40.1
39.1
49.5
44.9
43.9
24.2
19.8
18.8
29.4
24.9
23.9
34.5
30.0
29.0
39.8
35.1
34.1
44.6
40.0
39.0
49.4
44.9
43.9

33.7
33.7
33.7
33.6
33.6
33.6
33.6
33.6
33.6
33.6
33.6
33.6
31.3
31.3
31.3
29.0
29.0
29.0
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
30.3
30.3
30.3
28.7
28.7
28.7

4.07
3.81
3.72
4.98
4.67
4.55
6.10
5.72
5.58
7.44
6.97
6.80
7.73
7.25
7.07
8.50
7.96
7.76
3.87
3.62
3.53
4.78
4.47
4.35
5.82
5.45
5.31
7.16
6.70
6.53
7.56
7.08
6.89
8.48
7.94
7.73

25.0
20.2
19.2
30.1
25.3
24.2
35.3
30.4
29.3
40.6
35.5
34.4
45.1
40.3
39.2
49.7
45.1
44.1
24.4
19.9
18.9
29.6
25.0
24.0
34.8
30.1
29.1
40.1
35.2
34.2
44.8
40.1
39.1
49.6
45.0
44.0

Combi. : Combination
Temp. : Temperature

12

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

90
30

35

40

15

20

25

80
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

20.4
20.4
20.4
20.4
20.4
20.4
20.4
20.4
20.4
20.4
20.4
20.4
19.8
19.8
19.8
19.2
19.2
19.2
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1
18.1

2.03
1.87
1.81
2.50
2.30
2.24
3.05
2.81
2.73
3.75
3.45
3.36
4.05
3.72
3.62
4.65
4.28
4.16
1.70
1.56
1.52
2.10
1.93
1.88
2.56
2.35
2.29
3.15
2.89
2.81
3.50
3.21
3.13
4.14
3.81
3.70

21.0
18.1
17.5
26.1
23.2
22.6
31.3
28.3
27.6
36.4
33.4
32.7
41.4
38.3
37.7
46.5
43.4
42.7
20.4
17.8
17.2
25.5
22.8
22.3
30.6
27.9
27.3
35.7
33.0
32.4
40.9
38.1
37.4
46.1
43.2
42.5

TC:Total Capacity(kW)
PI :Power Input(kW)

13

22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0
21.4
21.4
21.4
20.8
20.8
20.8
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6

2.38
2.22
2.18
2.93
2.74
2.69
3.58
3.35
3.27
4.40
4.12
4.03
4.75
4.44
4.35
5.46
5.10
4.99
1.99
1.86
1.83
2.46
2.30
2.25
3.00
2.81
2.75
3.69
3.45
3.38
4.10
3.83
3.75
4.86
4.54
4.44

21.5
18.4
17.7
26.6
23.5
22.8
31.8
28.5
27.8
37.0
33.6
32.9
42.0
38.6
37.9
47.0
43.6
42.9
20.8
18.0
17.4
25.9
23.1
22.5
31.0
28.1
27.5
36.2
33.2
32.6
41.4
38.3
37.7
46.6
43.4
42.7

24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
23.3
23.3
23.3
22.7
22.7
22.7
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3

2.77
2.59
2.54
3.42
3.20
3.13
4.17
3.90
3.82
5.13
4.79
4.70
5.53
5.17
5.07
6.36
5.94
5.82
2.32
2.17
2.13
2.87
2.68
2.62
3.49
3.27
3.20
4.30
4.02
3.94
4.78
4.47
4.37
5.66
5.29
5.18

22.1
18.7
18.0
27.2
23.8
23.0
29.8
28.8
28.1
37.6
34.0
33.2
42.6
38.9
38.2
47.6
44.0
43.2
21.3
18.3
17.6
26.4
23.4
22.7
31.6
28.4
27.7
36.7
33.5
32.8
41.9
38.6
37.9
47.2
43.7
43.0

26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
25.4
25.4
25.4
24.7
24.7
24.7
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2

3.12
2.92
2.86
3.85
3.60
3.53
4.69
4.39
4.30
5.77
5.40
5.29
6.23
5.82
5.71
7.16
6.69
6.56
2.62
2.45
2.40
3.23
3.02
2.96
3.94
3.68
3.61
4.84
4.53
4.44
5.38
5.03
4.93
6.37
5.95
5.84

22.7
19.0
18.2
27.9
24.1
23.3
33.0
29.2
28.3
38.2
34.3
33.4
43.2
39.3
38.4
48.3
44.3
43.5
21.9
18.6
17.9
27.0
23.6
22.9
32.1
28.7
28.0
37.3
33.8
33.1
42.5
38.9
38.1
47.8
44.1
43.2

26.9
26.9
26.9
26.9
26.9
26.9
26.9
26.9
26.9
26.9
26.9
26.9
26.1
26.1
26.1
25.4
25.4
25.4
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9
23.9

3.20
2.99
2.93
3.94
3.69
3.62
4.81
4.49
4.41
5.91
5.53
5.42
6.38
5.96
5.85
7.33
6.85
6.72
2.68
2.50
2.46
3.30
3.09
3.03
4.03
3.77
3.70
4.96
4.63
4.55
5.51
5.15
5.05
6.52
6.10
5.98

23.0
19.1
18.3
28.1
24.2
23.4
33.3
29.3
28.4
38.5
34.4
33.5
43.5
39.4
38.5
48.5
44.4
43.6
22.1
18.7
17.9
27.2
23.8
23.0
32.3
28.8
28.1
37.6
33.9
33.1
42.8
39.0
38.2
48.0
44.2
43.3

27.9
27.9
27.9
27.9
27.9
27.9
27.9
27.9
27.9
27.9
27.9
27.9
27.2
27.2
27.2
26.4
26.4
26.4
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8
24.8

3.27
3.06
3.01
4.04
3.78
3.71
4.92
4.61
4.52
6.06
5.67
5.56
6.53
6.12
6.00
7.51
7.03
6.90
2.74
2.57
2.52
3.39
3.17
3.11
4.13
3.86
3.79
5.08
4.75
4.66
5.64
5.28
5.18
6.68
6.25
6.14

23.3
19.3
18.4
28.4
24.4
23.5
33.6
29.5
28.6
38.8
34.6
33.7
43.8
39.6
38.7
48.9
44.6
43.7
22.3
18.8
18.1
27.5
23.9
23.1
32.6
29.0
28.2
37.8
34.1
33.3
43.1
39.2
38.4
48.3
44.3
43.5

28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
27.9
27.9
27.9
27.1
27.1
27.1
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5

3.33
3.12
3.04
4.11
3.85
3.75
5.01
4.69
4.57
6.17
5.77
5.62
6.65
6.23
6.06
7.64
7.15
6.96
2.79
2.62
2.55
3.45
3.23
3.14
4.20
3.93
3.83
5.17
4.84
4.71
5.74
5.38
5.23
6.80
6.37
6.20

23.5
19.4
18.5
28.7
24.5
23.6
33.8
29.6
28.7
39.1
34.7
33.8
44.1
39.7
38.8
49.1
44.7
43.8
22.6
18.9
18.1
27.7
24.0
23.2
32.8
29.1
28.3
38.1
34.2
33.4
43.3
39.3
38.5
48.6
44.5
43.6

Combi. : Combination
Temp. : Temperature

Outdoor Units

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

70
30

35

40

15

20

25

60
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
15.8
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6

1.41
1.30
1.26
1.74
1.60
1.56
2.13
1.96
1.90
2.62
2.41
2.34
2.91
2.67
2.60
3.44
3.17
3.08
1.13
1.04
1.01
1.39
1.28
1.24
1.70
1.56
1.52
2.09
1.92
1.86
2.32
2.13
2.07
2.74
2.52
2.45

19.7
17.4
17.0
24.8
22.5
22.0
29.9
27.5
27.0
35.0
32.6
32.1
40.1
37.7
37.1
45.3
42.8
42.2
19.0
17.1
16.7
24.1
22.1
21.7
29.2
27.2
26.7
34.3
32.2
31.8
39.4
37.3
36.8
44.6
42.4
41.9

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
17.1
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7

1.66
1.55
1.52
2.05
1.91
1.87
2.49
2.33
2.28
3.07
2.87
2.81
3.41
3.19
3.12
4.04
3.77
3.69
1.32
1.24
1.21
1.63
1.52
1.49
1.99
1.86
1.82
2.45
2.29
2.24
2.72
2.54
2.49
3.22
3.01
2.94

20.1
17.6
17.1
25.2
22.7
22.2
30.3
27.7
27.2
35.4
32.8
32.3
40.6
37.9
37.3
45.8
43.0
42.4
19.3
17.3
16.8
24.4
22.3
21.8
29.5
27.4
26.9
34.6
32.4
31.9
39.8
37.5
37.0
44.9
42.6
42.1

18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
18.7
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0

1.93
1.81
1.77
2.38
2.23
2.18
2.91
2.72
2.66
3.57
3.34
3.27
3.97
3.71
3.64
4.70
4.40
4.31
1.54
1.44
1.41
1.90
1.78
1.74
2.32
2.17
2.12
2.85
2.66
2.61
3.17
2.96
2.90
3.75
3.50
3.43

20.5
17.9
17.3
25.6
22.9
22.3
30.7
28.0
27.4
35.9
33.1
32.5
41.1
38.2
37.5
46.3
43.3
42.6
19.7
17.5
17.0
24.8
22.5
22.0
29.9
27.6
27.1
35.1
32.6
32.1
40.2
37.7
37.2
45.4
42.8
42.2

20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4

2.18
2.03
1.99
2.68
2.51
2.46
3.27
3.06
3.00
4.02
3.76
3.69
4.47
4.18
4.10
5.30
4.95
4.85
1.73
1.62
1.59
2.14
2.00
1.96
2.61
2.44
2.39
3.21
3.00
2.94
3.56
3.33
3.27
4.22
3.95
3.87

21.0
18.1
17.5
26.1
23.2
22.6
31.2
28.2
27.6
36.4
33.3
32.7
41.6
38.4
37.7
46.8
43.6
42.8
20.1
17.7
17.1
25.2
22.7
22.2
30.3
27.8
27.2
35.5
32.9
32.3
40.6
37.9
37.4
45.8
43.0
42.4

20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
20.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9
17.9

2.23
2.08
2.04
2.75
2.57
2.52
3.35
3.13
3.07
4.12
3.85
3.78
4.58
4.28
4.20
5.42
5.07
4.97
1.78
1.66
1.63
2.19
2.05
2.01
2.67
2.50
2.45
3.28
3.07
3.01
3.65
3.41
3.35
4.32
4.04
3.97

21.2
18.2
17.6
26.3
23.3
22.6
31.4
28.3
27.7
36.6
33.4
32.8
41.8
38.5
37.8
47.0
43.7
42.9
20.3
17.8
17.2
25.4
22.8
22.3
30.5
27.9
27.3
35.7
32.9
32.4
40.8
38.0
37.4
46.0
43.1
42.5

21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
21.7
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6
18.6

2.28
2.14
2.10
2.81
2.63
2.58
3.43
3.21
3.15
4.22
3.95
3.88
4.69
4.39
4.31
5.55
5.20
5.10
1.82
1.70
1.67
2.24
2.10
2.06
2.74
2.56
2.51
3.37
3.15
3.09
3.74
3.50
3.43
4.43
4.14
4.07

21.4
18.3
17.7
26.6
23.4
22.7
31.7
28.5
27.8
36.9
33.6
32.9
42.1
38.7
37.9
47.3
43.8
43.0
20.5
17.9
17.3
25.6
22.9
22.3
30.7
28.0
27.4
35.9
33.1
32.5
41.0
38.1
37.5
46.3
43.3
42.6

22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1

2.32
2.17
2.12
2.87
2.68
2.61
3.49
3.27
3.18
4.30
4.02
3.92
4.78
4.47
4.35
5.65
5.29
5.15
1.85
1.73
1.69
2.28
2.14
2.08
2.79
2.61
2.54
3.43
3.21
3.12
3.81
3.56
3.47
4.51
4.22
4.11

21.6
18.4
17.8
26.7
23.5
22.8
31.9
28.6
27.9
37.1
33.7
32.9
42.2
38.8
38.0
47.5
43.9
43.1
20.7
17.9
17.4
25.8
23.0
22.4
30.9
28.1
27.5
36.0
33.1
32.5
41.2
38.2
37.6
46.4
43.4
42.7

Combi. : Combination
Temp. : Temperature

14

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

50
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3

0.84
0.77
0.75
1.04
0.95
0.93
1.26
1.16
1.13
1.55
1.43
1.39
1.73
1.59
1.54
2.05
1.88
1.83

18.3
16.7
16.4
23.4
21.8
21.4
28.5
26.8
26.4
33.6
31.9
31.5
38.7
36.9
36.5
43.8
42.0
41.6

TC:Total Capacity(kW)
PI :Power Input(kW)

15

12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2

0.99
0.92
0.90
1.22
1.14
1.11
1.48
1.39
1.36
1.82
1.71
1.67
2.03
1.89
1.85
2.40
2.24
2.20

18.6
16.9
16.5
23.7
21.9
21.5
28.8
27.0
26.6
33.9
32.0
31.6
39.0
37.1
36.7
44.1
42.1
41.7

13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3
13.3

1.15
1.07
1.05
1.42
1.32
1.30
1.73
1.61
1.58
2.12
1.99
1.95
2.36
2.21
2.16
2.79
2.61
2.56

18.9
17.1
16.6
24.0
22.1
21.7
29.1
27.1
26.7
34.2
32.2
31.8
39.3
37.3
36.8
44.5
42.3
41.9

14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5

1.29
1.21
1.19
1.59
1.49
1.46
1.94
1.82
1.78
2.39
2.24
2.19
2.66
2.49
2.44
3.15
2.94
2.89

19.3
17.2
16.8
24.4
22.3
21.8
29.5
27.3
26.9
34.6
32.4
31.9
39.7
37.5
37.0
44.9
42.5
42.0

14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9

1.32
1.24
1.21
1.63
1.53
1.50
1.99
1.86
1.83
2.45
2.29
2.25
2.72
2.54
2.50
3.22
3.01
2.96

19.4
17.3
16.8
24.5
22.3
21.9
29.6
27.4
26.9
34.7
32.5
32.0
39.8
37.5
37.0
45.0
42.6
42.1

15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5

1.36
1.27
1.25
1.67
1.57
1.54
2.04
1.91
1.87
2.51
2.35
2.30
2.79
2.61
2.56
3.30
3.09
3.03

19.6
17.4
16.9
24.7
22.4
21.9
29.8
27.5
27.0
34.9
32.6
32.0
40.0
37.6
37.1
45.2
42.7
42.2

16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0

1.38
1.29
1.26
1.70
1.59
1.55
2.08
1.94
1.89
2.55
2.39
2.33
2.84
2.66
2.59
3.36
3.15
3.06

19.7
17.5
17.0
24.8
22.5
22.0
29.9
27.6
27.0
35.0
32.6
32.1
40.2
37.7
37.2
45.4
42.8
42.2

Combi. : Combination
Temp. : Temperature

Outdoor Units

ARWN200LA2

Cooling Capacity
Indoor Air Temp.(CWB)

14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

130
30

35

40

15

20

25

120
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

53.0
53.0
53.0
52.3
52.3
52.3
52.3
52.3
52.3
52.3
52.3
52.3
47.0
47.0
47.0
41.8
41.8
41.8
50.4
50.4
50.4
49.9
49.9
49.9
49.9
49.9
49.9
49.9
49.9
49.9
45.7
45.7
45.7
41.4
41.4
41.4

5.24
4.82
4.69
6.35
5.84
5.68
7.84
7.21
7.01
9.40
8.65
8.41
9.51
8.74
8.50
10.0
9.22
8.97
5.01
4.61
4.48
6.11
5.62
5.46
7.51
6.91
6.71
9.08
8.35
8.12
9.31
8.56
8.32
10.0
9.21
8.96

22.8
19.1
18.3
27.9
24.1
23.3
33.0
29.2
28.3
38.3
34.3
33.4
42.6
39.0
38.2
47.0
43.7
42.9
22.5
18.9
18.1
27.5
23.9
23.1
32.7
29.0
28.2
37.9
34.1
33.3
42.4
38.9
38.1
47.0
43.6
42.9

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

57.4
57.4
57.4
56.6
56.6
56.6
56.6
56.6
56.6
56.6
56.6
56.6
50.9
50.9
50.9
45.3
45.3
45.3
54.6
54.6
54.6
54.1
54.1
54.1
54.1
54.1
54.1
54.1
54.1
54.1
49.5
49.5
49.5
44.9
44.9
44.9

6.11
5.72
5.60
7.41
6.93
6.78
9.14
8.55
8.36
11.0
10.3
10.0
11.1
10.4
10.1
11.7
10.9
10.7
5.85
5.47
5.35
7.13
6.66
6.52
8.76
8.19
8.01
10.6
9.90
9.69
10.9
10.1
9.93
11.7
10.9
10.7

23.5
19.4
18.5
28.5
24.4
23.6
33.7
29.5
28.6
38.9
34.7
33.7
43.3
39.3
38.4
47.6
44.0
43.2
23.1
19.2
18.4
28.2
24.2
23.4
33.3
29.3
28.5
38.5
34.4
33.6
43.0
39.2
38.3
47.5
43.9
43.1

62.6
62.6
62.6
61.6
61.6
61.6
61.6
61.6
61.6
61.6
61.6
61.6
55.5
55.5
55.5
49.3
49.3
49.3
59.5
59.5
59.5
58.9
58.9
58.9
58.9
58.9
58.9
58.9
58.9
58.9
53.9
53.9
53.9
48.9
48.9
48.9

7.12
6.66
6.52
8.63
8.07
7.91
10.6
9.95
9.75
12.8
11.9
11.7
12.9
12.1
11.8
13.6
12.7
12.5
6.81
6.37
6.24
8.30
7.76
7.60
10.2
9.54
9.34
12.3
11.5
11.3
12.6
11.8
11.6
13.6
12.7
12.5

24.3
19.8
18.9
29.3
24.8
23.9
29.3
29.9
28.9
39.7
35.1
34.1
44.0
39.7
38.8
48.3
44.3
43.5
23.8
19.6
18.7
28.9
24.6
23.7
28.9
29.7
28.8
39.3
34.8
33.9
43.7
39.6
38.6
48.2
44.3
43.4

68.0
68.0
68.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
60.3
60.3
60.3
53.6
53.6
53.6
64.7
64.7
64.7
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
58.6
58.6
58.6
53.1
53.1
53.1

8.02
7.50
7.35
9.72
9.09
8.91
12.0
11.2
11.0
14.4
13.5
13.2
14.5
13.6
13.3
15.3
14.3
14.1
7.67
7.17
7.03
9.35
8.74
8.57
11.5
10.7
10.5
13.9
13.0
12.7
14.2
13.3
13.1
15.3
14.3
14.0

25.1
20.2
19.2
30.1
25.3
24.2
35.3
30.4
29.3
40.6
35.5
34.4
44.8
40.1
39.1
49.0
44.7
43.8
24.6
20.0
19.0
29.7
25.0
24.0
34.8
30.1
29.1
40.1
35.3
34.2
44.5
40.0
39.0
48.9
44.7
43.7

70.0
70.0
70.0
69.0
69.0
69.0
69.0
69.0
69.0
69.0
69.0
69.0
62.1
62.1
62.1
55.2
55.2
55.2
66.6
66.6
66.6
65.9
65.9
65.9
65.9
65.9
65.9
65.9
65.9
65.9
60.3
60.3
60.3
54.7
54.7
54.7

8.21
7.69
7.54
9.95
9.31
9.14
12.3
11.5
11.3
14.7
13.8
13.5
14.9
13.9
13.7
15.7
14.7
14.4
7.85
7.35
7.21
9.57
8.95
8.79
11.8
11.0
10.8
14.2
13.3
13.1
14.6
13.6
13.4
15.7
14.7
14.4

25.4
20.4
19.3
30.4
25.4
24.3
35.6
30.5
29.4
40.9
35.7
34.5
45.1
40.3
39.2
49.3
44.8
43.9
24.9
20.1
19.1
29.9
25.2
24.1
35.1
30.3
29.2
40.4
35.4
34.3
44.8
40.1
39.1
49.2
44.8
43.8

72.8
72.8
72.8
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
64.5
64.5
64.5
57.4
57.4
57.4
69.2
69.2
69.2
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
62.7
62.7
62.7
56.9
56.9
56.9

8.41
7.89
7.74
10.2
9.56
9.37
12.6
11.8
11.6
15.1
14.2
13.9
15.3
14.3
14.0
16.1
15.1
14.8
8.05
7.54
7.40
9.81
9.19
9.01
12.1
11.3
11.1
14.6
13.7
13.4
14.9
14.0
13.7
16.1
15.1
14.8

25.8
20.6
19.5
30.8
25.6
24.5
36.0
30.7
29.6
41.3
35.9
34.7
45.5
40.5
39.4
49.6
45.0
44.0
25.2
20.3
19.3
30.3
25.4
24.3
35.5
30.5
29.4
40.8
35.6
34.5
45.2
40.3
39.2
49.6
45.0
44.0

74.8
74.8
74.8
73.7
73.7
73.7
73.7
73.7
73.7
73.7
73.7
73.7
66.3
66.3
66.3
59.0
59.0
59.0
71.1
71.1
71.1
70.4
70.4
70.4
70.4
70.4
70.4
70.4
70.4
70.4
64.4
64.4
64.4
58.5
58.5
58.5

8.57
8.05
7.87
10.4
9.75
9.53
12.8
12.0
11.8
15.4
14.4
14.1
15.5
14.6
14.3
16.4
15.4
15.1
8.19
7.69
7.51
9.98
9.37
9.15
12.3
11.5
11.2
14.8
13.9
13.6
15.2
14.3
13.9
16.4
15.4
15.0

26.1
20.8
19.6
31.1
25.8
24.6
36.3
30.9
29.7
41.6
36.1
34.9
45.8
40.6
39.5
49.9
45.2
44.1
25.5
20.5
19.4
30.6
25.5
24.4
35.8
30.6
29.5
41.1
35.8
34.6
45.5
40.4
39.4
49.8
45.1
44.1

Combi. : Combination
Temp. : Temperature

16

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

110
30

35

40

15

20

25

100
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

47.8
47.8
47.8
47.6
47.6
47.6
47.6
47.6
47.6
47.6
47.6
47.6
44.3
44.3
44.3
41.1
41.1
41.1
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
43.0
43.0
43.0
40.7
40.7
40.7

4.79
4.40
4.28
5.87
5.39
5.25
7.18
6.60
6.42
8.76
8.05
7.83
9.10
8.37
8.14
10.0
9.20
8.94
4.56
4.19
4.08
5.62
5.17
5.03
6.85
6.30
6.13
8.43
7.75
7.54
8.90
8.19
7.96
9.98
9.18
8.93

22.1
18.7
17.9
27.2
23.7
23.0
32.3
28.8
28.0
37.5
33.9
33.1
42.2
38.7
38.0
46.9
43.6
42.9
21.7
18.5
17.8
26.8
23.6
22.8
32.0
28.6
27.9
37.1
33.7
33.0
42.0
38.6
37.9
46.8
43.6
42.9

TC:Total Capacity(kW)
PI :Power Input(kW)

17

51.8
51.8
51.8
51.5
51.5
51.5
51.5
51.5
51.5
51.5
51.5
51.5
48.0
48.0
48.0
44.5
44.5
44.5
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
46.5
46.5
46.5
44.1
44.1
44.1

5.58
5.22
5.11
6.84
6.40
6.26
8.38
7.83
7.67
10.2
9.55
9.34
10.6
9.93
9.72
11.7
10.9
10.7
5.32
4.97
4.86
6.56
6.13
6.00
8.00
7.48
7.32
9.84
9.20
9.00
10.4
9.71
9.50
11.6
10.9
10.7

22.7
19.0
18.2
27.8
24.0
23.2
32.9
29.1
28.3
38.1
34.2
33.4
42.8
39.1
38.2
47.5
43.9
43.1
22.2
18.8
18.0
27.4
23.8
23.1
32.5
28.9
28.1
37.7
34.0
33.2
42.6
38.9
38.1
47.4
43.9
43.1

56.4
56.4
56.4
56.1
56.1
56.1
56.1
56.1
56.1
56.1
56.1
56.1
52.3
52.3
52.3
48.5
48.5
48.5
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
50.7
50.7
50.7
48.0
48.0
48.0

6.50
6.08
5.95
7.97
7.45
7.30
9.76
9.12
8.94
11.9
11.1
10.9
12.4
11.6
11.3
13.6
12.7
12.4
6.19
5.79
5.67
7.64
7.14
6.99
9.31
8.71
8.53
11.5
10.7
10.5
12.1
11.3
11.1
13.6
12.7
12.4

23.3
19.3
18.5
28.5
24.4
23.5
28.5
29.5
28.6
38.9
34.6
33.7
43.5
39.4
38.5
48.1
44.2
43.4
22.9
19.1
18.3
28.0
24.2
23.4
28.0
29.3
28.4
38.4
34.4
33.5
43.2
39.3
38.4
48.1
44.2
43.4

61.3
61.3
61.3
61.0
61.0
61.0
61.0
61.0
61.0
61.0
61.0
61.0
56.8
56.8
56.8
52.7
52.7
52.7
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
55.1
55.1
55.1
52.2
52.2
52.2

7.32
6.85
6.71
8.97
8.39
8.23
11.0
10.3
10.1
13.4
12.5
12.3
13.9
13.0
12.8
15.3
14.3
14.0
6.97
6.52
6.39
8.60
8.04
7.88
10.5
9.81
9.61
12.9
12.1
11.8
13.6
12.7
12.5
15.3
14.3
14.0

24.1
19.7
18.8
29.2
24.8
23.8
34.4
29.9
28.9
39.6
35.0
34.0
44.2
39.8
38.8
48.9
44.6
43.7
23.6
19.5
18.6
28.7
24.6
23.6
33.9
29.6
28.7
39.2
34.8
33.8
43.9
39.7
38.7
48.8
44.6
43.7

63.2
63.2
63.2
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
58.5
58.5
58.5
54.2
54.2
54.2
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
56.8
56.8
56.8
53.8
53.8
53.8

7.50
7.01
6.88
9.19
8.59
8.43
11.3
10.5
10.3
13.7
12.8
12.6
14.3
13.3
13.1
15.7
14.7
14.4
7.14
6.68
6.55
8.81
8.23
8.08
10.7
10.0
9.85
13.2
12.3
12.1
13.9
13.0
12.8
15.6
14.6
14.4

24.3
19.9
18.9
29.5
24.9
23.9
34.7
30.0
29.0
39.9
35.2
34.1
44.5
39.9
39.0
49.1
44.7
43.8
23.8
19.6
18.7
29.0
24.7
23.8
34.2
29.8
28.8
39.4
34.9
33.9
44.2
39.8
38.8
49.0
44.7
43.8

65.6
65.6
65.6
65.3
65.3
65.3
65.3
65.3
65.3
65.3
65.3
65.3
60.8
60.8
60.8
56.4
56.4
56.4
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
59.0
59.0
59.0
55.9
55.9
55.9

7.68
7.19
7.06
9.41
8.82
8.65
11.5
10.8
10.6
14.1
13.2
12.9
14.6
13.7
13.4
16.0
15.0
14.7
7.32
6.85
6.72
9.02
8.44
8.29
11.0
10.3
10.1
13.5
12.7
12.4
14.3
13.4
13.1
16.0
15.0
14.7

24.7
20.1
19.0
29.8
25.1
24.1
35.0
30.2
29.2
40.3
35.4
34.3
44.9
40.1
39.1
49.5
44.9
43.9
24.2
19.8
18.8
29.4
24.9
23.9
34.5
30.0
29.0
39.8
35.1
34.1
44.6
40.0
39.0
49.4
44.9
43.9

67.5
67.5
67.5
67.1
67.1
67.1
67.1
67.1
67.1
67.1
67.1
67.1
62.5
62.5
62.5
57.9
57.9
57.9
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
60.6
60.6
60.6
57.4
57.4
57.4

7.82
7.33
7.15
9.58
8.98
8.76
11.7
11.0
10.7
14.3
13.4
13.1
14.9
13.9
13.6
16.3
15.3
14.9
7.45
6.97
6.79
9.18
8.60
8.37
11.2
10.5
10.2
13.8
12.9
12.6
14.5
13.6
13.3
16.3
15.3
14.9

25.0
20.2
19.2
30.1
25.3
24.2
35.3
30.4
29.3
40.6
35.5
34.4
45.1
40.3
39.2
49.7
45.1
44.1
24.4
19.9
18.9
29.6
25.0
24.0
34.8
30.1
29.1
40.1
35.2
34.2
44.8
40.1
39.1
49.6
45.0
44.0

Combi. : Combination
Temp. : Temperature

Outdoor Units

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

90
30

35

40

15

20

25

80
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
39.6
39.6
39.6
38.5
38.5
38.5
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2

3.92
3.61
3.51
4.84
4.45
4.33
5.90
5.43
5.28
7.26
6.67
6.49
7.83
7.20
7.00
8.99
8.27
8.04
3.29
3.02
2.94
4.06
3.73
3.63
4.95
4.55
4.42
6.08
5.60
5.44
6.76
6.22
6.05
8.01
7.36
7.16

21.0
18.1
17.5
26.1
23.2
22.6
31.3
28.3
27.6
36.4
33.4
32.7
41.4
38.3
37.7
46.5
43.4
42.7
20.4
17.8
17.2
25.5
22.8
22.3
30.6
27.9
27.3
35.7
33.0
32.4
40.9
38.1
37.4
46.1
43.2
42.5

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
42.9
42.9
42.9
41.6
41.6
41.6
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2
39.2

4.58
4.28
4.19
5.64
5.28
5.16
6.88
6.44
6.30
8.47
7.92
7.75
9.13
8.54
8.36
10.5
9.81
9.60
3.84
3.59
3.51
4.73
4.42
4.33
5.77
5.39
5.28
7.10
6.64
6.49
7.89
7.37
7.22
9.34
8.73
8.54

21.5
18.4
17.7
26.6
23.5
22.8
31.8
28.5
27.8
37.0
33.6
32.9
42.0
38.6
37.9
47.0
43.6
42.9
20.8
18.0
17.4
25.9
23.1
22.5
31.0
28.1
27.5
36.2
33.2
32.6
41.4
38.3
37.7
46.6
43.4
42.7

48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
46.7
46.7
46.7
45.4
45.4
45.4
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7

5.33
4.98
4.88
6.57
6.15
6.02
8.02
7.50
7.34
9.86
9.22
9.03
10.6
9.95
9.74
12.2
11.4
11.2
4.47
4.18
4.09
5.51
5.15
5.05
6.72
6.28
6.15
8.27
7.73
7.57
9.18
8.59
8.41
10.9
10.2
9.96

22.1
18.7
18.0
27.2
23.8
23.0
29.8
28.8
28.1
37.6
34.0
33.2
42.6
38.9
38.2
47.6
44.0
43.2
21.3
18.3
17.6
26.4
23.4
22.7
31.6
28.4
27.7
36.7
33.5
32.8
41.9
38.6
37.9
47.2
43.7
43.0

52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
50.8
50.8
50.8
49.3
49.3
49.3
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4

6.00
5.61
5.50
7.40
6.92
6.79
9.03
8.44
8.28
11.1
10.4
10.2
12.0
11.2
11.0
13.8
12.9
12.6
5.03
4.70
4.61
6.21
5.80
5.69
7.57
7.08
6.94
9.31
8.70
8.53
10.3
9.67
9.48
12.2
11.5
11.2

22.7
19.0
18.2
27.9
24.1
23.3
33.0
29.2
28.3
38.2
34.3
33.4
43.2
39.3
38.4
48.3
44.3
43.5
21.9
18.6
17.9
27.0
23.6
22.9
32.1
28.7
28.0
37.3
33.8
33.1
42.5
38.9
38.1
47.8
44.1
43.2

53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
52.3
52.3
52.3
50.8
50.8
50.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8

6.15
5.75
5.64
7.58
7.09
6.96
9.24
8.64
8.48
11.4
10.6
10.4
12.3
11.5
11.3
14.1
13.2
12.9
5.15
4.82
4.73
6.35
5.94
5.83
7.75
7.24
7.11
9.53
8.91
8.75
10.6
9.90
9.72
12.5
11.7
11.5

23.0
19.1
18.3
28.1
24.2
23.4
33.3
29.3
28.4
38.5
34.4
33.5
43.5
39.4
38.5
48.5
44.4
43.6
22.1
18.7
17.9
27.2
23.8
23.0
32.3
28.8
28.1
37.6
33.9
33.1
42.8
39.0
38.2
48.0
44.2
43.3

55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
54.3
54.3
54.3
52.8
52.8
52.8
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6
49.6

6.30
5.89
5.78
7.77
7.27
7.13
9.47
8.86
8.70
11.6
10.9
10.7
12.6
11.8
11.5
14.4
13.5
13.3
5.28
4.94
4.85
6.51
6.09
5.98
7.94
7.43
7.29
9.77
9.14
8.97
10.9
10.2
9.97
12.8
12.0
11.8

23.3
19.3
18.4
28.4
24.4
23.5
33.6
29.5
28.6
38.8
34.6
33.7
43.8
39.6
38.7
48.9
44.6
43.7
22.3
18.8
18.1
27.5
23.9
23.1
32.6
29.0
28.2
37.8
34.1
33.3
43.1
39.2
38.4
48.3
44.3
43.5

57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
55.8
55.8
55.8
54.2
54.2
54.2
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0

6.41
6.00
5.84
7.91
7.40
7.20
9.64
9.02
8.79
11.9
11.1
10.8
12.8
12.0
11.7
14.7
13.8
13.4
5.37
5.03
4.90
6.63
6.20
6.04
8.08
7.56
7.37
9.94
9.30
9.06
11.0
10.3
10.1
13.1
12.2
11.9

23.5
19.4
18.5
28.7
24.5
23.6
33.8
29.6
28.7
39.1
34.7
33.8
44.1
39.7
38.8
49.1
44.7
43.8
22.6
18.9
18.1
27.7
24.0
23.2
32.8
29.1
28.3
38.1
34.2
33.4
43.3
39.3
38.5
48.6
44.5
43.6

Combi. : Combination
Temp. : Temperature

18

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

70
30

35

40

15

20

25

60
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
31.7
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1
27.1

2.73
2.51
2.45
3.37
3.10
3.02
4.11
3.78
3.68
5.06
4.65
4.52
5.62
5.17
5.03
6.66
6.12
5.95
2.18
2.00
1.95
2.69
2.47
2.40
3.28
3.02
2.93
4.03
3.71
3.61
4.48
4.12
4.01
5.31
4.88
4.74

19.7
17.4
17.0
24.8
22.5
22.0
29.9
27.5
27.0
35.0
32.6
32.1
40.1
37.7
37.1
45.3
42.8
42.2
19.0
17.1
16.7
24.1
22.1
21.7
29.2
27.2
26.7
34.3
32.2
31.8
39.4
37.3
36.8
44.6
42.4
41.9

TC:Total Capacity(kW)
PI :Power Input(kW)

19

34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
34.3
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4

3.19
2.98
2.92
3.93
3.68
3.60
4.80
4.49
4.39
5.90
5.52
5.40
6.56
6.13
6.00
7.76
7.26
7.10
2.54
2.38
2.33
3.14
2.93
2.87
3.82
3.58
3.50
4.70
4.40
4.30
5.23
4.89
4.78
6.19
5.79
5.66

20.1
17.6
17.1
25.2
22.7
22.2
30.3
27.7
27.2
35.4
32.8
32.3
40.6
37.9
37.3
45.8
43.0
42.4
19.3
17.3
16.8
24.4
22.3
21.8
29.5
27.4
26.9
34.6
32.4
31.9
39.8
37.5
37.0
44.9
42.6
42.1

37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
37.4
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0
32.0

3.71
3.47
3.40
4.58
4.28
4.20
5.59
5.22
5.12
6.87
6.43
6.29
7.64
7.14
6.99
9.04
8.46
8.28
2.96
2.77
2.71
3.65
3.42
3.34
4.45
4.16
4.08
5.48
5.12
5.02
6.09
5.69
5.57
7.21
6.74
6.60

20.5
17.9
17.3
25.6
22.9
22.3
30.7
28.0
27.4
35.9
33.1
32.5
41.1
38.2
37.5
46.3
43.3
42.6
19.7
17.5
17.0
24.8
22.5
22.0
29.9
27.6
27.1
35.1
32.6
32.1
40.2
37.7
37.2
45.4
42.8
42.2

40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8

4.18
3.91
3.83
5.16
4.82
4.73
6.29
5.88
5.77
7.74
7.24
7.09
8.60
8.04
7.88
10.2
9.52
9.33
3.33
3.12
3.06
4.11
3.85
3.77
5.02
4.69
4.60
6.17
5.77
5.66
6.86
6.41
6.28
8.12
7.59
7.44

21.0
18.1
17.5
26.1
23.2
22.6
31.2
28.2
27.6
36.4
33.3
32.7
41.6
38.4
37.7
46.8
43.6
42.8
20.1
17.7
17.1
25.2
22.7
22.2
30.3
27.8
27.2
35.5
32.9
32.3
40.6
37.9
37.4
45.8
43.0
42.4

41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
41.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8
35.8

4.28
4.00
3.93
5.28
4.94
4.85
6.44
6.02
5.91
7.92
7.41
7.27
8.80
8.23
8.08
10.4
9.75
9.57
3.41
3.19
3.13
4.21
3.94
3.86
5.14
4.80
4.71
6.32
5.91
5.80
7.02
6.56
6.44
8.31
7.77
7.63

21.2
18.2
17.6
26.3
23.3
22.6
31.4
28.3
27.7
36.6
33.4
32.8
41.8
38.5
37.8
47.0
43.7
42.9
20.3
17.8
17.2
25.4
22.8
22.3
30.5
27.9
27.3
35.7
32.9
32.4
40.8
38.0
37.4
46.0
43.1
42.5

43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
43.4
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2
37.2

4.39
4.11
4.03
5.41
5.07
4.97
6.60
6.18
6.06
8.12
7.60
7.46
9.02
8.44
8.29
10.7
10.0
9.81
3.50
3.27
3.21
4.31
4.04
3.96
5.26
4.92
4.83
6.47
6.06
5.94
7.19
6.73
6.60
8.52
7.97
7.82

21.4
18.3
17.7
26.6
23.4
22.7
31.7
28.5
27.8
36.9
33.6
32.9
42.1
38.7
37.9
47.3
43.8
43.0
20.5
17.9
17.3
25.6
22.9
22.3
30.7
28.0
27.4
35.9
33.1
32.5
41.0
38.1
37.5
46.3
43.3
42.6

44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
44.7
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3

4.47
4.18
4.07
5.51
5.16
5.02
6.72
6.29
6.12
8.27
7.74
7.53
9.18
8.59
8.37
10.9
10.2
9.91
3.56
3.33
3.25
4.39
4.11
4.00
5.36
5.01
4.88
6.59
6.17
6.00
7.32
6.85
6.67
8.67
8.11
7.90

21.6
18.4
17.8
26.7
23.5
22.8
31.9
28.6
27.9
37.1
33.7
32.9
42.2
38.8
38.0
47.5
43.9
43.1
20.7
17.9
17.4
25.8
23.0
22.4
30.9
28.1
27.5
36.0
33.1
32.5
41.2
38.2
37.6
46.4
43.4
42.7

Combi. : Combination
Temp. : Temperature

Outdoor Units

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

50
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6
22.6

1.63
1.49
1.45
2.00
1.84
1.79
2.44
2.25
2.19
3.01
2.77
2.69
3.34
3.07
2.99
3.96
3.64
3.54

18.3
16.7
16.4
23.4
21.8
21.4
28.5
26.8
26.4
33.6
31.9
31.5
38.7
36.9
36.5
43.8
42.0
41.6

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5

1.90
1.77
1.73
2.34
2.19
2.14
2.85
2.67
2.61
3.51
3.28
3.21
3.90
3.64
3.57
4.61
4.31
4.22

18.6
16.9
16.5
23.7
21.9
21.5
28.8
27.0
26.6
33.9
32.0
31.6
39.0
37.1
36.7
44.1
42.1
41.7

26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7

2.21
2.06
2.02
2.72
2.55
2.49
3.32
3.11
3.04
4.09
3.82
3.74
4.54
4.24
4.16
5.38
5.03
4.92

18.9
17.1
16.6
24.0
22.1
21.7
29.1
27.1
26.7
34.2
32.2
31.8
39.3
37.3
36.8
44.5
42.3
41.9

29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0

2.49
2.32
2.28
3.07
2.87
2.81
3.74
3.50
3.43
4.60
4.30
4.22
5.11
4.78
4.69
6.05
5.66
5.55

19.3
17.2
16.8
24.4
22.3
21.8
29.5
27.3
26.9
34.6
32.4
31.9
39.7
37.5
37.0
44.9
42.5
42.0

29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9
29.9

2.55
2.38
2.34
3.14
2.94
2.88
3.83
3.58
3.51
4.71
4.40
4.32
5.23
4.89
4.80
6.20
5.79
5.69

19.4
17.3
16.8
24.5
22.3
21.9
29.6
27.4
26.9
34.7
32.5
32.0
39.8
37.5
37.0
45.0
42.6
42.1

31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0

2.61
2.44
2.40
3.22
3.01
2.95
3.92
3.67
3.60
4.83
4.52
4.43
5.36
5.02
4.92
6.35
5.94
5.83

19.6
17.4
16.9
24.7
22.4
21.9
29.8
27.5
27.0
34.9
32.6
32.0
40.0
37.6
37.1
45.2
42.7
42.2

31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9

2.66
2.49
2.42
3.28
3.07
2.98
3.99
3.74
3.64
4.91
4.60
4.48
5.46
5.11
4.97
6.46
6.05
5.89

19.7
17.5
17.0
24.8
22.5
22.0
29.9
27.6
27.0
35.0
32.6
32.1
40.2
37.7
37.2
45.4
42.8
42.2

Combi. : Combination
Temp. : Temperature

20

ARWN300LA2
Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

130
30

35

40

15

20

25

120
30

35

40

150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360

79.6
79.6
79.6
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
70.6
70.6
70.6
62.7
62.7
62.7
75.7
75.7
75.7
74.9
74.9
74.9
74.9
74.9
74.9
74.9
74.9
74.9
68.5
68.5
68.5
62.2
62.2
62.2

7.95
7.31
7.11
9.64
8.86
8.62
11.9
10.9
10.6
14.3
13.1
12.8
14.4
13.3
12.9
15.2
14.0
13.6
7.61
7.00
6.80
9.27
8.52
8.29
11.4
10.5
10.2
13.8
12.7
12.3
14.1
13.0
12.6
15.2
14.0
13.6

22.8
19.1
18.3
27.9
24.1
23.3
33.0
29.2
28.3
38.3
34.3
33.4
42.6
39.0
38.2
47.0
43.7
42.9
22.5
18.9
18.1
27.5
23.9
23.1
32.7
29.0
28.2
37.9
34.1
33.3
42.4
38.9
38.1
47.0
43.6
42.9

TC:Total Capacity(kW)
PI :Power Input(kW)

21

86.1
86.1
86.1
84.9
84.9
84.9
84.9
84.9
84.9
84.9
84.9
84.9
76.4
76.4
76.4
67.9
67.9
67.9
81.9
81.9
81.9
81.1
81.1
81.1
81.1
81.1
81.1
81.1
81.1
81.1
74.2
74.2
74.2
67.3
67.3
67.3

9.29
8.69
8.50
11.3
10.5
10.3
13.9
13.0
12.7
16.7
15.6
15.3
16.9
15.8
15.4
17.8
16.6
16.3
8.89
8.31
8.13
10.8
10.1
9.91
13.3
12.4
12.2
16.1
15.1
14.7
16.5
15.4
15.1
17.8
16.6
16.2

23.5
19.4
18.5
28.5
24.4
23.6
33.7
29.5
28.6
38.9
34.7
33.7
43.3
39.3
38.4
47.6
44.0
43.2
23.1
19.2
18.4
28.2
24.2
23.4
33.3
29.3
28.5
38.5
34.4
33.6
43.0
39.2
38.3
47.5
43.9
43.1

93.8
93.8
93.8
92.5
92.5
92.5
92.5
92.5
92.5
92.5
92.5
92.5
83.2
83.2
83.2
74.0
74.0
74.0
89.2
89.2
89.2
88.3
88.3
88.3
88.3
88.3
88.3
88.3
88.3
88.3
80.8
80.8
80.8
73.3
73.3
73.3

10.8
10.1
9.91
13.1
12.3
12.0
16.2
15.1
14.8
19.4
18.2
17.8
19.6
18.4
18.0
20.7
19.4
19.0
10.4
9.68
9.48
12.6
11.8
11.6
15.5
14.5
14.2
18.7
17.5
17.2
19.2
18.0
17.6
20.7
19.3
18.9

24.3
19.8
18.9
29.3
24.8
23.9
29.3
29.9
28.9
39.7
35.1
34.1
44.0
39.7
38.8
48.3
44.3
43.5
23.8
19.6
18.7
28.9
24.6
23.7
28.9
29.7
28.8
39.3
34.8
33.9
43.7
39.6
38.6
48.2
44.3
43.4

102.0
102.0
102.0
100.5
100.5
100.5
100.5
100.5
100.5
100.5
100.5
100.5
90.5
90.5
90.5
80.4
80.4
80.4
97.0
97.0
97.0
96.0
96.0
96.0
96.0
96.0
96.0
96.0
96.0
96.0
87.9
87.9
87.9
79.7
79.7
79.7

12.2
11.4
11.2
14.8
13.8
13.5
18.2
17.0
16.7
21.9
20.4
20.0
22.1
20.7
20.3
23.3
21.8
21.4
11.7
10.9
10.7
14.2
13.3
13.0
17.5
16.3
16.0
21.1
19.7
19.4
21.6
20.2
19.8
23.3
21.8
21.3

25.1
20.2
19.2
30.1
25.3
24.2
35.3
30.4
29.3
40.6
35.5
34.4
44.8
40.1
39.1
49.0
44.7
43.8
24.6
20.0
19.0
29.7
25.0
24.0
34.8
30.1
29.1
40.1
35.3
34.2
44.5
40.0
39.0
48.9
44.7
43.7

105.0
105.0
105.0
103.5
103.5
103.5
103.5
103.5
103.5
103.5
103.5
103.5
93.2
93.2
93.2
82.8
82.8
82.8
99.9
99.9
99.9
98.9
98.9
98.9
98.9
98.9
98.9
98.9
98.9
98.9
90.5
90.5
90.5
82.1
82.1
82.1

12.5
11.7
11.5
15.1
14.2
13.9
18.7
17.5
17.1
22.4
21.0
20.6
22.6
21.2
20.8
23.9
22.4
21.9
11.9
11.2
11.0
14.5
13.6
13.4
17.9
16.7
16.4
21.6
20.2
19.8
22.2
20.7
20.3
23.8
22.3
21.9

25.4
20.4
19.3
30.4
25.4
24.3
35.6
30.5
29.4
40.9
35.7
34.5
45.1
40.3
39.2
49.3
44.8
43.9
24.9
20.1
19.1
29.9
25.2
24.1
35.1
30.3
29.2
40.4
35.4
34.3
44.8
40.1
39.1
49.2
44.8
43.8

109.1
109.1
109.1
107.5
107.5
107.5
107.5
107.5
107.5
107.5
107.5
107.5
96.8
96.8
96.8
86.0
86.0
86.0
103.8
103.8
103.8
102.7
102.7
102.7
102.7
102.7
102.7
102.7
102.7
102.7
94.0
94.0
94.0
85.3
85.3
85.3

12.8
12.0
11.8
15.5
14.5
14.2
19.1
17.9
17.6
22.9
21.5
21.1
23.2
21.8
21.3
24.5
22.9
22.5
12.2
11.5
11.2
14.9
14.0
13.7
18.3
17.2
16.8
22.1
20.8
20.4
22.7
21.3
20.9
24.4
22.9
22.5

25.8
20.6
19.5
30.8
25.6
24.5
36.0
30.7
29.6
41.3
35.9
34.7
45.5
40.5
39.4
49.6
45.0
44.0
25.2
20.3
19.3
30.3
25.4
24.3
35.5
30.5
29.4
40.8
35.6
34.5
45.2
40.3
39.2
49.6
45.0
44.0

112.2
112.2
112.2
110.6
110.6
110.6
110.6
110.6
110.6
110.6
110.6
110.6
99.5
99.5
99.5
88.4
88.4
88.4
106.7
106.7
106.7
105.6
105.6
105.6
105.6
105.6
105.6
105.6
105.6
105.6
96.6
96.6
96.6
87.7
87.7
87.7

13.0
12.2
12.0
15.8
14.8
14.5
19.5
18.3
17.9
23.4
21.9
21.4
23.6
22.2
21.7
24.9
23.4
22.9
12.5
11.7
11.4
15.2
14.2
13.9
18.6
17.5
17.1
22.5
21.2
20.7
23.1
21.7
21.2
24.9
23.3
22.8

26.1
20.8
19.6
31.1
25.8
24.6
36.3
30.9
29.7
41.6
36.1
34.9
45.8
40.6
39.5
49.9
45.2
44.1
25.5
20.5
19.4
30.6
25.5
24.4
35.8
30.6
29.5
41.1
35.8
34.6
45.5
40.4
39.4
49.8
45.1
44.1

Combi. : Combination
Temp. : Temperature

Outdoor Units

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

110
30

35

40

15

20

25

100
30

35

40

150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360

71.8
71.8
71.8
71.4
71.4
71.4
71.4
71.4
71.4
71.4
71.4
71.4
66.5
66.5
66.5
61.6
61.6
61.6
67.9
67.9
67.9
67.9
67.9
67.9
67.9
67.9
67.9
67.9
67.9
67.9
64.5
64.5
64.5
61.1
61.1
61.1

7.26
6.68
6.49
8.90
8.18
7.96
10.9
10.0
9.74
13.3
12.2
11.9
13.8
12.7
12.4
15.2
14.0
13.6
6.91
6.36
6.18
8.53
7.84
7.63
10.4
9.56
9.30
12.8
11.8
11.4
13.5
12.4
12.1
15.1
13.9
13.5

22.1
18.7
17.9
27.2
23.7
23.0
32.3
28.8
28.0
37.5
33.9
33.1
42.2
38.7
38.0
46.9
43.6
42.9
21.7
18.5
17.8
26.8
23.6
22.8
32.0
28.6
27.9
37.1
33.7
33.0
42.0
38.6
37.9
46.8
43.6
42.9

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

77.7
77.7
77.7
77.3
77.3
77.3
77.3
77.3
77.3
77.3
77.3
77.3
72.0
72.0
72.0
66.7
66.7
66.7
73.5
73.5
73.5
73.5
73.5
73.5
73.5
73.5
73.5
73.5
73.5
73.5
69.8
69.8
69.8
66.1
66.1
66.1

8.49
7.93
7.76
10.4
9.72
9.51
12.7
11.9
11.7
15.5
14.5
14.2
16.1
15.1
14.8
17.7
16.6
16.2
8.08
7.56
7.39
9.97
9.32
9.12
12.2
11.4
11.1
14.9
14.0
13.7
15.8
14.8
14.4
17.7
16.6
16.2

22.7
19.0
18.2
27.8
24.0
23.2
32.9
29.1
28.3
38.1
34.2
33.4
42.8
39.1
38.2
47.5
43.9
43.1
22.2
18.8
18.0
27.4
23.8
23.1
32.5
28.9
28.1
37.7
34.0
33.2
42.6
38.9
38.1
47.4
43.9
43.1

84.6
84.6
84.6
84.2
84.2
84.2
84.2
84.2
84.2
84.2
84.2
84.2
78.4
78.4
78.4
72.7
72.7
72.7
80.0
80.0
80.0
80.0
80.0
80.0
80.0
80.0
80.0
80.0
80.0
80.0
76.0
76.0
76.0
72.0
72.0
72.0

9.88
9.24
9.05
12.1
11.3
11.1
14.8
13.9
13.6
18.1
16.9
16.6
18.8
17.6
17.2
20.7
19.3
18.9
9.41
8.80
8.62
11.6
10.9
10.6
14.2
13.2
13.0
17.4
16.3
15.9
18.4
17.2
16.8
20.6
19.3
18.9

23.3
19.3
18.5
28.5
24.4
23.5
28.5
29.5
28.6
38.9
34.6
33.7
43.5
39.4
38.5
48.1
44.2
43.4
22.9
19.1
18.3
28.0
24.2
23.4
28.0
29.3
28.4
38.4
34.4
33.5
43.2
39.3
38.4
48.1
44.2
43.4

92.0
92.0
92.0
91.5
91.5
91.5
91.5
91.5
91.5
91.5
91.5
91.5
85.3
85.3
85.3
79.0
79.0
79.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
82.7
82.7
82.7
78.3
78.3
78.3

11.1
10.4
10.2
13.6
12.8
12.5
16.7
15.6
15.3
20.4
19.0
18.7
21.2
19.8
19.4
23.3
21.7
21.3
10.6
9.91
9.72
13.1
12.2
12.0
15.9
14.9
14.6
19.6
18.3
18.0
20.7
19.4
19.0
23.2
21.7
21.3

24.1
19.7
18.8
29.2
24.8
23.8
34.4
29.9
28.9
39.6
35.0
34.0
44.2
39.8
38.8
48.9
44.6
43.7
23.6
19.5
18.6
28.7
24.6
23.6
33.9
29.6
28.7
39.2
34.8
33.8
43.9
39.7
38.7
48.8
44.6
43.7

94.8
94.8
94.8
94.2
94.2
94.2
94.2
94.2
94.2
94.2
94.2
94.2
87.8
87.8
87.8
81.4
81.4
81.4
89.6
89.6
89.6
89.6
89.6
89.6
89.6
89.6
89.6
89.6
89.6
89.6
85.1
85.1
85.1
80.6
80.6
80.6

11.4
10.7
10.5
14.0
13.1
12.8
17.1
16.0
15.7
20.8
19.5
19.1
21.7
20.3
19.9
23.8
22.3
21.9
10.9
10.1
9.96
13.4
12.5
12.3
16.3
15.3
15.0
20.1
18.8
18.4
21.2
19.8
19.4
23.8
22.2
21.8

24.3
19.9
18.9
29.5
24.9
23.9
34.7
30.0
29.0
39.9
35.2
34.1
44.5
39.9
39.0
49.1
44.7
43.8
23.8
19.6
18.7
29.0
24.7
23.8
34.2
29.8
28.8
39.4
34.9
33.9
44.2
39.8
38.8
49.0
44.7
43.8

98.4
98.4
98.4
97.9
97.9
97.9
97.9
97.9
97.9
97.9
97.9
97.9
91.2
91.2
91.2
84.5
84.5
84.5
93.1
93.1
93.1
93.1
93.1
93.1
93.1
93.1
93.1
93.1
93.1
93.1
88.4
88.4
88.4
83.8
83.8
83.8

11.7
10.9
10.7
14.3
13.4
13.1
17.5
16.4
16.1
21.4
20.0
19.6
22.2
20.8
20.4
24.4
22.8
22.4
11.1
10.4
10.2
13.7
12.8
12.6
16.7
15.7
15.4
20.6
19.3
18.9
21.7
20.3
19.9
24.4
22.8
22.4

24.7
20.1
19.0
29.8
25.1
24.1
35.0
30.2
29.2
40.3
35.4
34.3
44.9
40.1
39.1
49.5
44.9
43.9
24.2
19.8
18.8
29.4
24.9
23.9
34.5
30.0
29.0
39.8
35.1
34.1
44.6
40.0
39.0
49.4
44.9
43.9

101.2
101.2
101.2
100.7
100.7
100.7
100.7
100.7
100.7
100.7
100.7
100.7
93.8
93.8
93.8
86.9
86.9
86.9
95.7
95.7
95.7
95.7
95.7
95.7
95.7
95.7
95.7
95.7
95.7
95.7
90.9
90.9
90.9
86.1
86.1
86.1

11.9
11.1
10.9
14.6
13.7
13.3
17.8
16.7
16.3
21.7
20.4
19.9
22.6
21.2
20.7
24.8
23.3
22.7
11.3
10.6
10.3
14.0
13.1
12.7
17.0
15.9
15.5
20.9
19.6
19.1
22.1
20.7
20.1
24.8
23.2
22.6

25.0
20.2
19.2
30.1
25.3
24.2
35.3
30.4
29.3
40.6
35.5
34.4
45.1
40.3
39.2
49.7
45.1
44.1
24.4
19.9
18.9
29.6
25.0
24.0
34.8
30.1
29.1
40.1
35.2
34.2
44.8
40.1
39.1
49.6
45.0
44.0

Combi. : Combination
Temp. : Temperature

22

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

90
30

35

40

15

20

25

80
30

35

40

150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360

61.1
61.1
61.1
61.1
61.1
61.1
61.1
61.1
61.1
61.1
61.1
61.1
59.4
59.4
59.4
57.7
57.7
57.7
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3

5.95
5.47
5.32
7.34
6.75
6.56
8.95
8.23
8.01
11.0
10.1
9.85
11.9
10.9
10.6
13.6
12.6
12.2
4.99
4.59
4.46
6.15
5.66
5.50
7.50
6.90
6.71
9.23
8.49
8.25
10.3
9.43
9.17
12.1
11.2
10.9

21.0
18.1
17.5
26.1
23.2
22.6
31.3
28.3
27.6
36.4
33.4
32.7
41.4
38.3
37.7
46.5
43.4
42.7
20.4
17.8
17.2
25.5
22.8
22.3
30.6
27.9
27.3
35.7
33.0
32.4
40.9
38.1
37.4
46.1
43.2
42.5

TC:Total Capacity(kW)
PI :Power Input(kW)

23

66.1
66.1
66.1
66.1
66.1
66.1
66.1
66.1
66.1
66.1
66.1
66.1
64.3
64.3
64.3
62.5
62.5
62.5
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8

6.96
6.50
6.36
8.58
8.02
7.85
10.5
9.78
9.57
12.9
12.0
11.8
13.9
13.0
12.7
15.9
14.9
14.6
5.83
5.45
5.34
7.19
6.72
6.58
8.77
8.20
8.02
10.8
10.1
9.87
12.0
11.2
11.0
14.2
13.3
13.0

21.5
18.4
17.7
26.6
23.5
22.8
31.8
28.5
27.8
37.0
33.6
32.9
42.0
38.6
37.9
47.0
43.6
42.9
20.8
18.0
17.4
25.9
23.1
22.5
31.0
28.1
27.5
36.2
33.2
32.6
41.4
38.3
37.7
46.6
43.4
42.7

72.0
72.0
72.0
72.0
72.0
72.0
72.0
72.0
72.0
72.0
72.0
72.0
70.0
70.0
70.0
68.0
68.0
68.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0

8.10
7.58
7.42
10.0
9.34
9.15
12.2
11.4
11.2
15.0
14.0
13.7
16.2
15.1
14.8
18.6
17.4
17.0
6.79
6.35
6.22
8.38
7.83
7.67
10.2
9.55
9.35
12.6
11.7
11.5
14.0
13.1
12.8
16.5
15.5
15.1

22.1
18.7
18.0
27.2
23.8
23.0
29.8
28.8
28.1
37.6
34.0
33.2
42.6
38.9
38.2
47.6
44.0
43.2
21.3
18.3
17.6
26.4
23.4
22.7
31.6
28.4
27.7
36.7
33.5
32.8
41.9
38.6
37.9
47.2
43.7
43.0

78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
76.1
76.1
76.1
74.0
74.0
74.0
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6

9.12
8.53
8.36
11.3
10.5
10.3
13.7
12.8
12.6
16.9
15.8
15.5
18.2
17.0
16.7
20.9
19.6
19.2
7.65
7.15
7.01
9.43
8.82
8.65
11.5
10.8
10.5
14.1
13.2
13.0
15.7
14.7
14.4
18.6
17.4
17.1

22.7
19.0
18.2
27.9
24.1
23.3
33.0
29.2
28.3
38.2
34.3
33.4
43.2
39.3
38.4
48.3
44.3
43.5
21.9
18.6
17.9
27.0
23.6
22.9
32.1
28.7
28.0
37.3
33.8
33.1
42.5
38.9
38.1
47.8
44.1
43.2

80.6
80.6
80.6
80.6
80.6
80.6
80.6
80.6
80.6
80.6
80.6
80.6
78.4
78.4
78.4
76.2
76.2
76.2
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7

9.34
8.73
8.57
11.5
10.8
10.6
14.1
13.1
12.9
17.3
16.2
15.9
18.6
17.4
17.1
21.4
20.0
19.7
7.83
7.32
7.19
9.66
9.03
8.86
11.8
11.0
10.8
14.5
13.5
13.3
16.1
15.0
14.8
19.1
17.8
17.5

23.0
19.1
18.3
28.1
24.2
23.4
33.3
29.3
28.4
38.5
34.4
33.5
43.5
39.4
38.5
48.5
44.4
43.6
22.1
18.7
17.9
27.2
23.8
23.0
32.3
28.8
28.1
37.6
33.9
33.1
42.8
39.0
38.2
48.0
44.2
43.3

83.8
83.8
83.8
83.8
83.8
83.8
83.8
83.8
83.8
83.8
83.8
83.8
81.5
81.5
81.5
79.1
79.1
79.1
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5

9.57
8.96
8.79
11.8
11.0
10.8
14.4
13.5
13.2
17.7
16.6
16.3
19.1
17.9
17.5
21.9
20.5
20.2
8.02
7.51
7.37
9.90
9.26
9.09
12.1
11.3
11.1
14.8
13.9
13.6
16.5
15.4
15.1
19.5
18.3
17.9

23.3
19.3
18.4
28.4
24.4
23.5
33.6
29.5
28.6
38.8
34.6
33.7
43.8
39.6
38.7
48.9
44.6
43.7
22.3
18.8
18.1
27.5
23.9
23.1
32.6
29.0
28.2
37.8
34.1
33.3
43.1
39.2
38.4
48.3
44.3
43.5

86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
83.7
83.7
83.7
81.3
81.3
81.3
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6

9.74
9.12
8.88
12.0
11.2
11.0
14.7
13.7
13.4
18.0
16.9
16.4
19.4
18.2
17.7
22.3
20.9
20.4
8.17
7.64
7.44
10.1
9.43
9.18
12.3
11.5
11.2
15.1
14.1
13.8
16.8
15.7
15.3
19.9
18.6
18.1

23.5
19.4
18.5
28.7
24.5
23.6
33.8
29.6
28.7
39.1
34.7
33.8
44.1
39.7
38.8
49.1
44.7
43.8
22.6
18.9
18.1
27.7
24.0
23.2
32.8
29.1
28.3
38.1
34.2
33.4
43.3
39.3
38.5
48.6
44.5
43.6

Combi. : Combination
Temp. : Temperature

Outdoor Units

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

70
30

35

40

15

20

25

60
30

35

40

150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360

47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7

4.15
3.81
3.71
5.12
4.70
4.58
6.24
5.74
5.58
7.67
7.06
6.86
8.53
7.84
7.63
10.1
9.29
9.03
3.31
3.04
2.96
4.08
3.75
3.65
4.97
4.57
4.45
6.12
5.63
5.47
6.80
6.25
6.08
8.05
7.40
7.20

19.7
17.4
17.0
24.8
22.5
22.0
29.9
27.5
27.0
35.0
32.6
32.1
40.1
37.7
37.1
45.3
42.8
42.2
19.0
17.1
16.7
24.1
22.1
21.7
29.2
27.2
26.7
34.3
32.2
31.8
39.4
37.3
36.8
44.6
42.4
41.9

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
51.4
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1
44.1

4.85
4.53
4.44
5.98
5.59
5.47
7.29
6.82
6.67
8.97
8.39
8.21
9.96
9.32
9.12
11.8
11.0
10.8
3.86
3.61
3.54
4.77
4.46
4.36
5.81
5.43
5.32
7.15
6.68
6.54
7.94
7.43
7.27
9.41
8.80
8.61

20.1
17.6
17.1
25.2
22.7
22.2
30.3
27.7
27.2
35.4
32.8
32.3
40.6
37.9
37.3
45.8
43.0
42.4
19.3
17.3
16.8
24.4
22.3
21.8
29.5
27.4
26.9
34.6
32.4
31.9
39.8
37.5
37.0
44.9
42.6
42.1

56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
56.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0

5.65
5.28
5.17
6.96
6.51
6.38
8.49
7.94
7.78
10.4
9.77
9.57
11.6
10.9
10.6
13.7
12.9
12.6
4.50
4.21
4.12
5.55
5.19
5.08
6.77
6.33
6.20
8.33
7.79
7.63
9.25
8.65
8.47
11.0
10.2
10.0

20.5
17.9
17.3
25.6
22.9
22.3
30.7
28.0
27.4
35.9
33.1
32.5
41.1
38.2
37.5
46.3
43.3
42.6
19.7
17.5
17.0
24.8
22.5
22.0
29.9
27.6
27.1
35.1
32.6
32.1
40.2
37.7
37.2
45.4
42.8
42.2

60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2

6.36
5.95
5.83
7.84
7.33
7.19
9.56
8.94
8.77
11.8
11.0
10.8
13.1
12.2
12.0
15.5
14.5
14.2
5.07
4.74
4.65
6.25
5.85
5.73
7.62
7.13
6.99
9.38
8.77
8.60
10.4
9.74
9.55
12.3
11.5
11.3

21.0
18.1
17.5
26.1
23.2
22.6
31.2
28.2
27.6
36.4
33.3
32.7
41.6
38.4
37.7
46.8
43.6
42.8
20.1
17.7
17.1
25.2
22.7
22.2
30.3
27.8
27.2
35.5
32.9
32.3
40.6
37.9
37.4
45.8
43.0
42.4

62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
62.7
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8
53.8

6.51
6.09
5.97
8.03
7.51
7.37
9.79
9.16
8.98
12.0
11.3
11.1
13.4
12.5
12.3
15.8
14.8
14.5
5.19
4.85
4.76
6.40
5.98
5.87
7.81
7.30
7.16
9.60
8.98
8.81
10.7
9.97
9.79
12.6
11.8
11.6

21.2
18.2
17.6
26.3
23.3
22.6
31.4
28.3
27.7
36.6
33.4
32.8
41.8
38.5
37.8
47.0
43.7
42.9
20.3
17.8
17.2
25.4
22.8
22.3
30.5
27.9
27.3
35.7
32.9
32.4
40.8
38.0
37.4
46.0
43.1
42.5

65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9
55.9

6.67
6.24
6.13
8.23
7.70
7.56
10.0
9.39
9.21
12.3
11.5
11.3
13.7
12.8
12.6
16.2
15.2
14.9
5.32
4.98
4.88
6.56
6.14
6.02
8.00
7.49
7.35
9.84
9.21
9.04
10.9
10.2
10.0
12.9
12.1
11.9

21.4
18.3
17.7
26.6
23.4
22.7
31.7
28.5
27.8
36.9
33.6
32.9
42.1
38.7
37.9
47.3
43.8
43.0
20.5
17.9
17.3
25.6
22.9
22.3
30.7
28.0
27.4
35.9
33.1
32.5
41.0
38.1
37.5
46.3
43.3
42.6

67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4

6.79
6.36
6.19
8.38
7.84
7.63
10.2
9.56
9.31
12.6
11.8
11.4
14.0
13.1
12.7
16.5
15.5
15.1
5.41
5.07
4.93
6.68
6.25
6.08
8.14
7.62
7.42
10.0
9.37
9.13
11.1
10.4
10.1
13.2
12.3
12.0

21.6
18.4
17.8
26.7
23.5
22.8
31.9
28.6
27.9
37.1
33.7
32.9
42.2
38.8
38.0
47.5
43.9
43.1
20.7
17.9
17.4
25.8
23.0
22.4
30.9
28.1
27.5
36.0
33.1
32.5
41.2
38.2
37.6
46.4
43.4
42.7

Combi. : Combination
Temp. : Temperature

24

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

50
30

35

40

150
288
360
150
288
360
150
288
360
150
288
360
150
288
360
150
288
360

33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9
33.9

2.47
2.27
2.21
3.04
2.80
2.72
3.71
3.41
3.32
4.56
4.19
4.08
5.07
4.66
4.53
6.00
5.52
5.37

18.3
16.7
16.4
23.4
21.8
21.4
28.5
26.8
26.4
33.6
31.9
31.5
38.7
36.9
36.5
43.8
42.0
41.6

TC:Total Capacity(kW)
PI :Power Input(kW)

25

36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7

2.88
2.69
2.64
3.55
3.32
3.25
4.33
4.05
3.97
5.33
4.98
4.88
5.92
5.54
5.42
7.01
6.56
6.42

18.6
16.9
16.5
23.7
21.9
21.5
28.8
27.0
26.6
33.9
32.0
31.6
39.0
37.1
36.7
44.1
42.1
41.7

40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0

3.36
3.14
3.07
4.14
3.87
3.79
5.05
4.72
4.62
6.21
5.81
5.69
6.90
6.45
6.32
8.17
7.64
7.48

18.9
17.1
16.6
24.0
22.1
21.7
29.1
27.1
26.7
34.2
32.2
31.8
39.3
37.3
36.8
44.5
42.3
41.9

43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5

3.78
3.53
3.46
4.66
4.36
4.27
5.68
5.32
5.21
6.99
6.54
6.41
7.77
7.26
7.12
9.20
8.60
8.43

19.3
17.2
16.8
24.4
22.3
21.8
29.5
27.3
26.9
34.6
32.4
31.9
39.7
37.5
37.0
44.9
42.5
42.0

44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8
44.8

3.87
3.62
3.55
4.77
4.46
4.38
5.82
5.44
5.34
7.16
6.69
6.57
7.95
7.44
7.30
9.42
8.81
8.64

19.4
17.3
16.8
24.5
22.3
21.9
29.6
27.4
26.9
34.7
32.5
32.0
39.8
37.5
37.0
45.0
42.6
42.1

46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5

3.96
3.71
3.64
4.89
4.58
4.49
5.96
5.58
5.48
7.34
6.86
6.74
8.15
7.63
7.49
9.65
9.03
8.86

19.6
17.4
16.9
24.7
22.4
21.9
29.8
27.5
27.0
34.9
32.6
32.0
40.0
37.6
37.1
45.2
42.7
42.2

47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9
47.9

4.04
3.78
3.68
4.98
4.66
4.54
6.07
5.68
5.53
7.47
6.99
6.81
8.30
7.77
7.56
9.83
9.20
8.95

19.7
17.5
17.0
24.8
22.5
22.0
29.9
27.6
27.0
35.0
32.6
32.1
40.2
37.7
37.2
45.4
42.8
42.2

Combi. : Combination
Temp. : Temperature

Outdoor Units

ARWN400LA2
Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

130
30

35

40

15

20

25

120
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

106.1
106.1
106.1
104.5
104.5
104.5
104.5
104.5
104.5
104.5
104.5
104.5
94.1
94.1
94.1
83.6
83.6
83.6
100.9
100.9
100.9
99.8
99.8
99.8
99.8
99.8
99.8
99.8
99.8
99.8
91.4
91.4
91.4
82.9
82.9
82.9

10.5
9.64
9.38
12.7
11.7
11.4
15.7
14.4
14.0
18.8
17.3
16.8
19.0
17.5
17.0
20.1
18.4
17.9
10.0
9.22
8.97
12.2
11.2
10.9
15.0
13.8
13.4
18.2
16.7
16.2
18.6
17.1
16.6
20.0
18.4
17.9

22.8
19.1
18.3
27.9
24.1
23.3
33.0
29.2
28.3
38.3
34.3
33.4
42.6
39.0
38.2
47.0
43.7
42.9
22.5
18.9
18.1
27.5
23.9
23.1
32.7
29.0
28.2
37.9
34.1
33.3
42.4
38.9
38.1
47.0
43.6
42.9

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

114.9
114.9
114.9
113.2
113.2
113.2
113.2
113.2
113.2
113.2
113.2
113.2
101.9
101.9
101.9
90.6
90.6
90.6
109.2
109.2
109.2
108.1
108.1
108.1
108.1
108.1
108.1
108.1
108.1
108.1
99.0
99.0
99.0
89.8
89.8
89.8

12.2
11.4
11.2
14.8
13.9
13.6
18.3
17.1
16.7
21.9
20.5
20.1
22.2
20.7
20.3
23.4
21.9
21.4
11.7
10.9
10.7
14.3
13.3
13.0
17.5
16.4
16.0
21.2
19.8
19.4
21.7
20.3
19.9
23.4
21.8
21.4

23.5
19.4
18.5
28.5
24.4
23.6
33.7
29.5
28.6
38.9
34.7
33.7
43.3
39.3
38.4
47.6
44.0
43.2
23.1
19.2
18.4
28.2
24.2
23.4
33.3
29.3
28.5
38.5
34.4
33.6
43.0
39.2
38.3
47.5
43.9
43.1

125.1
125.1
125.1
123.3
123.3
123.3
123.3
123.3
123.3
123.3
123.3
123.3
111.0
111.0
111.0
98.6
98.6
98.6
119.0
119.0
119.0
117.8
117.8
117.8
117.8
117.8
117.8
117.8
117.8
117.8
107.8
107.8
107.8
97.8
97.8
97.8

14.2
13.3
13.0
17.3
16.1
15.8
21.3
19.9
19.5
25.6
23.9
23.4
25.8
24.2
23.7
27.3
25.5
25.0
13.6
12.7
12.5
16.6
15.5
15.2
20.4
19.1
18.7
24.7
23.1
22.6
25.3
23.6
23.2
27.2
25.4
24.9

24.3
19.8
18.9
29.3
24.8
23.9
29.3
29.9
28.9
39.7
35.1
34.1
44.0
39.7
38.8
48.3
44.3
43.5
23.8
19.6
18.7
28.9
24.6
23.7
28.9
29.7
28.8
39.3
34.8
33.9
43.7
39.6
38.6
48.2
44.3
43.4

136.0
136.0
136.0
134.0
134.0
134.0
134.0
134.0
134.0
134.0
134.0
134.0
120.6
120.6
120.6
107.2
107.2
107.2
129.3
129.3
129.3
128.0
128.0
128.0
128.0
128.0
128.0
128.0
128.0
128.0
117.1
117.1
117.1
106.3
106.3
106.3

16.0
15.0
14.7
19.4
18.2
17.8
24.0
22.4
22.0
28.8
26.9
26.4
29.1
27.2
26.7
30.7
28.7
28.1
15.3
14.3
14.1
18.7
17.5
17.1
23.0
21.5
21.1
27.8
26.0
25.5
28.5
26.6
26.1
30.6
28.7
28.1

25.1
20.2
19.2
30.1
25.3
24.2
35.3
30.4
29.3
40.6
35.5
34.4
44.8
40.1
39.1
49.0
44.7
43.8
24.6
20.0
19.0
29.7
25.0
24.0
34.8
30.1
29.1
40.1
35.3
34.2
44.5
40.0
39.0
48.9
44.7
43.7

140.1
140.1
140.1
138.0
138.0
138.0
138.0
138.0
138.0
138.0
138.0
138.0
124.2
124.2
124.2
110.4
110.4
110.4
133.2
133.2
133.2
131.9
131.9
131.9
131.9
131.9
131.9
131.9
131.9
131.9
120.7
120.7
120.7
109.5
109.5
109.5

16.4
15.4
15.1
19.9
18.6
18.3
24.5
23.0
22.5
29.5
27.6
27.1
29.8
27.9
27.4
31.4
29.4
28.9
15.7
14.7
14.4
19.1
17.9
17.6
23.5
22.0
21.6
28.4
26.6
26.1
29.2
27.3
26.8
31.4
29.4
28.8

25.4
20.4
19.3
30.4
25.4
24.3
35.6
30.5
29.4
40.9
35.7
34.5
45.1
40.3
39.2
49.3
44.8
43.9
24.9
20.1
19.1
29.9
25.2
24.1
35.1
30.3
29.2
40.4
35.4
34.3
44.8
40.1
39.1
49.2
44.8
43.8

145.5
145.5
145.5
143.4
143.4
143.4
143.4
143.4
143.4
143.4
143.4
143.4
129.1
129.1
129.1
114.7
114.7
114.7
138.4
138.4
138.4
137.0
137.0
137.0
137.0
137.0
137.0
137.0
137.0
137.0
125.3
125.3
125.3
113.7
113.7
113.7

16.8
15.8
15.5
20.4
19.1
18.7
25.2
23.6
23.1
30.2
28.3
27.7
30.5
28.6
28.1
32.2
30.2
29.6
16.1
15.1
14.8
19.6
18.4
18.0
24.1
22.6
22.2
29.1
27.3
26.8
29.9
28.0
27.5
32.1
30.1
29.5

25.8
20.6
19.5
30.8
25.6
24.5
36.0
30.7
29.6
41.3
35.9
34.7
45.5
40.5
39.4
49.6
45.0
44.0
25.2
20.3
19.3
30.3
25.4
24.3
35.5
30.5
29.4
40.8
35.6
34.5
45.2
40.3
39.2
49.6
45.0
44.0

149.6
149.6
149.6
147.4
147.4
147.4
147.4
147.4
147.4
147.4
147.4
147.4
132.7
132.7
132.7
117.9
117.9
117.9
142.3
142.3
142.3
140.8
140.8
140.8
140.8
140.8
140.8
140.8
140.8
140.8
128.9
128.9
128.9
116.9
116.9
116.9

17.1
16.1
15.7
20.8
19.5
19.1
25.6
24.1
23.5
30.7
28.9
28.2
31.1
29.2
28.5
32.8
30.8
30.1
16.4
15.4
15.0
20.0
18.7
18.3
24.5
23.0
22.5
29.7
27.8
27.2
30.4
28.5
27.9
32.7
30.7
30.0

26.1
20.8
19.6
31.1
25.8
24.6
36.3
30.9
29.7
41.6
36.1
34.9
45.8
40.6
39.5
49.9
45.2
44.1
25.5
20.5
19.4
30.6
25.5
24.4
35.8
30.6
29.5
41.1
35.8
34.6
45.5
40.4
39.4
49.8
45.1
44.1

Combi. : Combination
Temp. : Temperature

26

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

110
30

35

40

15

20

25

100
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

95.7
95.7
95.7
95.2
95.2
95.2
95.2
95.2
95.2
95.2
95.2
95.2
88.7
88.7
88.7
82.2
82.2
82.2
90.5
90.5
90.5
90.5
90.5
90.5
90.5
90.5
90.5
90.5
90.5
90.5
86.0
86.0
86.0
81.4
81.4
81.4

9.57
8.80
8.56
11.7
10.8
10.5
14.4
13.2
12.8
17.5
16.1
15.7
18.2
16.7
16.3
20.0
18.4
17.9
9.12
8.38
8.15
11.2
10.3
10.1
13.7
12.6
12.3
16.9
15.5
15.1
17.8
16.4
15.9
20.0
18.4
17.9

22.1
18.7
17.9
27.2
23.7
23.0
32.3
28.8
28.0
37.5
33.9
33.1
42.2
38.7
38.0
46.9
43.6
42.9
21.7
18.5
17.8
26.8
23.6
22.8
32.0
28.6
27.9
37.1
33.7
33.0
42.0
38.6
37.9
46.8
43.6
42.9

TC:Total Capacity(kW)
PI :Power Input(kW)

27

103.6
103.6
103.6
103.1
103.1
103.1
103.1
103.1
103.1
103.1
103.1
103.1
96.0
96.0
96.0
89.0
89.0
89.0
98.0
98.0
98.0
98.0
98.0
98.0
98.0
98.0
98.0
98.0
98.0
98.0
93.1
93.1
93.1
88.2
88.2
88.2

11.2
10.4
10.2
13.7
12.8
12.5
16.8
15.7
15.3
20.4
19.1
18.7
21.2
19.9
19.4
23.3
21.8
21.3
10.6
9.94
9.73
13.1
12.3
12.0
16.0
15.0
14.6
19.7
18.4
18.0
20.8
19.4
19.0
23.3
21.8
21.3

22.7
19.0
18.2
27.8
24.0
23.2
32.9
29.1
28.3
38.1
34.2
33.4
42.8
39.1
38.2
47.5
43.9
43.1
22.2
18.8
18.0
27.4
23.8
23.1
32.5
28.9
28.1
37.7
34.0
33.2
42.6
38.9
38.1
47.4
43.9
43.1

112.8
112.8
112.8
112.2
112.2
112.2
112.2
112.2
112.2
112.2
112.2
112.2
104.6
104.6
104.6
96.9
96.9
96.9
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
101.4
101.4
101.4
96.0
96.0
96.0

13.0
12.2
11.9
15.9
14.9
14.6
19.5
18.2
17.9
23.8
22.2
21.8
24.7
23.1
22.7
27.2
25.4
24.9
12.4
11.6
11.3
15.3
14.3
14.0
18.6
17.4
17.1
22.9
21.4
21.0
24.2
22.6
22.1
27.1
25.4
24.8

23.3
19.3
18.5
28.5
24.4
23.5
28.5
29.5
28.6
38.9
34.6
33.7
43.5
39.4
38.5
48.1
44.2
43.4
22.9
19.1
18.3
28.0
24.2
23.4
28.0
29.3
28.4
38.4
34.4
33.5
43.2
39.3
38.4
48.1
44.2
43.4

122.7
122.7
122.7
122.0
122.0
122.0
122.0
122.0
122.0
122.0
122.0
122.0
113.7
113.7
113.7
105.3
105.3
105.3
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
110.2
110.2
110.2
104.4
104.4
104.4

14.6
13.7
13.4
17.9
16.8
16.5
22.0
20.5
20.1
26.8
25.1
24.6
27.9
26.0
25.5
30.6
28.6
28.0
13.9
13.0
12.8
17.2
16.1
15.8
21.0
19.6
19.2
25.8
24.1
23.7
27.2
25.5
25.0
30.6
28.6
28.0

24.1
19.7
18.8
29.2
24.8
23.8
34.4
29.9
28.9
39.6
35.0
34.0
44.2
39.8
38.8
48.9
44.6
43.7
23.6
19.5
18.6
28.7
24.6
23.6
33.9
29.6
28.7
39.2
34.8
33.8
43.9
39.7
38.7
48.8
44.6
43.7

126.3
126.3
126.3
125.7
125.7
125.7
125.7
125.7
125.7
125.7
125.7
125.7
117.1
117.1
117.1
108.5
108.5
108.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
113.5
113.5
113.5
107.5
107.5
107.5

15.0
14.0
13.8
18.4
17.2
16.9
22.5
21.0
20.7
27.4
25.7
25.2
28.5
26.7
26.2
31.3
29.3
28.8
14.3
13.4
13.1
17.6
16.5
16.2
21.5
20.1
19.7
26.4
24.7
24.2
27.9
26.1
25.6
31.3
29.2
28.7

24.3
19.9
18.9
29.5
24.9
23.9
34.7
30.0
29.0
39.9
35.2
34.1
44.5
39.9
39.0
49.1
44.7
43.8
23.8
19.6
18.7
29.0
24.7
23.8
34.2
29.8
28.8
39.4
34.9
33.9
44.2
39.8
38.8
49.0
44.7
43.8

131.2
131.2
131.2
130.5
130.5
130.5
130.5
130.5
130.5
130.5
130.5
130.5
121.6
121.6
121.6
112.7
112.7
112.7
124.1
124.1
124.1
124.1
124.1
124.1
124.1
124.1
124.1
124.1
124.1
124.1
117.9
117.9
117.9
111.7
111.7
111.7

15.4
14.4
14.1
18.8
17.6
17.3
23.1
21.6
21.2
28.1
26.3
25.8
29.2
27.4
26.8
32.1
30.1
29.5
14.6
13.7
13.4
18.0
16.9
16.6
22.0
20.6
20.2
27.1
25.3
24.9
28.6
26.7
26.2
32.1
30.0
29.4

24.7
20.1
19.0
29.8
25.1
24.1
35.0
30.2
29.2
40.3
35.4
34.3
44.9
40.1
39.1
49.5
44.9
43.9
24.2
19.8
18.8
29.4
24.9
23.9
34.5
30.0
29.0
39.8
35.1
34.1
44.6
40.0
39.0
49.4
44.9
43.9

134.9
134.9
134.9
134.2
134.2
134.2
134.2
134.2
134.2
134.2
134.2
134.2
125.0
125.0
125.0
115.9
115.9
115.9
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
121.2
121.2
121.2
114.8
114.8
114.8

15.6
14.7
14.3
19.2
18.0
17.5
23.5
22.0
21.4
28.6
26.8
26.1
29.7
27.9
27.2
32.7
30.6
29.9
14.9
13.9
13.6
18.4
17.2
16.7
22.4
21.0
20.4
27.6
25.8
25.1
29.1
27.2
26.5
32.6
30.5
29.7

25.0
20.2
19.2
30.1
25.3
24.2
35.3
30.4
29.3
40.6
35.5
34.4
45.1
40.3
39.2
49.7
45.1
44.1
24.4
19.9
18.9
29.6
25.0
24.0
34.8
30.1
29.1
40.1
35.2
34.2
44.8
40.1
39.1
49.6
45.0
44.0

Combi. : Combination
Temp. : Temperature

Outdoor Units

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

90
30

35

40

15

20

25

80
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

81.4
81.4
81.4
81.4
81.4
81.4
81.4
81.4
81.4
81.4
81.4
81.4
79.2
79.2
79.2
76.9
76.9
76.9
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4
72.4

7.85
7.22
7.02
9.68
8.90
8.65
11.8
10.9
10.6
14.5
13.3
13.0
15.7
14.4
14.0
18.0
16.5
16.1
6.58
6.05
5.88
8.11
7.46
7.25
9.89
9.10
8.85
12.2
11.2
10.9
13.5
12.4
12.1
16.0
14.7
14.3

21.0
18.1
17.5
26.1
23.2
22.6
31.3
28.3
27.6
36.4
33.4
32.7
41.4
38.3
37.7
46.5
43.4
42.7
20.4
17.8
17.2
25.5
22.8
22.3
30.6
27.9
27.3
35.7
33.0
32.4
40.9
38.1
37.4
46.1
43.2
42.5

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

88.2
88.2
88.2
88.2
88.2
88.2
88.2
88.2
88.2
88.2
88.2
88.2
85.7
85.7
85.7
83.3
83.3
83.3
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4
78.4

9.15
8.56
8.37
11.3
10.6
10.3
13.8
12.9
12.6
16.9
15.8
15.5
18.3
17.1
16.7
21.0
19.6
19.2
7.67
7.17
7.02
9.46
8.85
8.66
11.5
10.8
10.6
14.2
13.3
13.0
15.8
14.7
14.4
18.7
17.5
17.1

21.5
18.4
17.7
26.6
23.5
22.8
31.8
28.5
27.8
37.0
33.6
32.9
42.0
38.6
37.9
47.0
43.6
42.9
20.8
18.0
17.4
25.9
23.1
22.5
31.0
28.1
27.5
36.2
33.2
32.6
41.4
38.3
37.7
46.6
43.4
42.7

96.0
96.0
96.0
96.0
96.0
96.0
96.0
96.0
96.0
96.0
96.0
96.0
93.4
93.4
93.4
90.7
90.7
90.7
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4
85.4

10.7
9.97
9.76
13.1
12.3
12.0
16.0
15.0
14.7
19.7
18.4
18.1
21.3
19.9
19.5
24.4
22.9
22.4
8.94
8.36
8.18
11.0
10.3
10.1
13.4
12.6
12.3
16.5
15.5
15.1
18.4
17.2
16.8
21.8
20.3
19.9

22.1
18.7
18.0
27.2
23.8
23.0
29.8
28.8
28.1
37.6
34.0
33.2
42.6
38.9
38.2
47.6
44.0
43.2
21.3
18.3
17.6
26.4
23.4
22.7
31.6
28.4
27.7
36.7
33.5
32.8
41.9
38.6
37.9
47.2
43.7
43.0

104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
101.5
101.5
101.5
98.6
98.6
98.6
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8

12.0
11.2
11.0
14.8
13.8
13.6
18.1
16.9
16.6
22.2
20.8
20.4
24.0
22.4
22.0
27.5
25.7
25.2
10.1
9.41
9.22
12.4
11.6
11.4
15.1
14.2
13.9
18.6
17.4
17.1
20.7
19.3
19.0
24.5
22.9
22.5

22.7
19.0
18.2
27.9
24.1
23.3
33.0
29.2
28.3
38.2
34.3
33.4
43.2
39.3
38.4
48.3
44.3
43.5
21.9
18.6
17.9
27.0
23.6
22.9
32.1
28.7
28.0
37.3
33.8
33.1
42.5
38.9
38.1
47.8
44.1
43.2

107.5
107.5
107.5
107.5
107.5
107.5
107.5
107.5
107.5
107.5
107.5
107.5
104.5
104.5
104.5
101.6
101.6
101.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6

12.3
11.5
11.3
15.2
14.2
13.9
18.5
17.3
17.0
22.7
21.3
20.9
24.5
22.9
22.5
28.2
26.4
25.9
10.3
9.63
9.45
12.7
11.9
11.7
15.5
14.5
14.2
19.1
17.8
17.5
21.2
19.8
19.4
25.1
23.5
23.0

23.0
19.1
18.3
28.1
24.2
23.4
33.3
29.3
28.4
38.5
34.4
33.5
43.5
39.4
38.5
48.5
44.4
43.6
22.1
18.7
17.9
27.2
23.8
23.0
32.3
28.8
28.1
37.6
33.9
33.1
42.8
39.0
38.2
48.0
44.2
43.3

111.7
111.7
111.7
111.7
111.7
111.7
111.7
111.7
111.7
111.7
111.7
111.7
108.6
108.6
108.6
105.5
105.5
105.5
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3
99.3

12.6
11.8
11.6
15.5
14.5
14.3
18.9
17.7
17.4
23.3
21.8
21.4
25.1
23.5
23.1
28.9
27.0
26.5
10.6
9.88
9.70
13.0
12.2
12.0
15.9
14.9
14.6
19.5
18.3
17.9
21.7
20.3
19.9
25.7
24.1
23.6

23.3
19.3
18.4
28.4
24.4
23.5
33.6
29.5
28.6
38.8
34.6
33.7
43.8
39.6
38.7
48.9
44.6
43.7
22.3
18.8
18.1
27.5
23.9
23.1
32.6
29.0
28.2
37.8
34.1
33.3
43.1
39.2
38.4
48.3
44.3
43.5

114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
111.7
111.7
111.7
108.5
108.5
108.5
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1
102.1

12.8
12.0
11.7
15.8
14.8
14.4
19.3
18.0
17.6
23.7
22.2
21.6
25.6
23.9
23.3
29.4
27.5
26.8
10.7
10.1
9.79
13.3
12.4
12.1
16.2
15.1
14.7
19.9
18.6
18.1
22.1
20.7
20.1
26.2
24.5
23.8

23.5
19.4
18.5
28.7
24.5
23.6
33.8
29.6
28.7
39.1
34.7
33.8
44.1
39.7
38.8
49.1
44.7
43.8
22.6
18.9
18.1
27.7
24.0
23.2
32.8
29.1
28.3
38.1
34.2
33.4
43.3
39.3
38.5
48.6
44.5
43.6

Combi. : Combination
Temp. : Temperature

28

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

70
30

35

40

15

20

25

60
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
63.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3
54.3

5.47
5.03
4.89
6.74
6.20
6.03
8.22
7.56
7.36
10.1
9.30
9.05
11.2
10.3
10.1
13.3
12.2
11.9
4.36
4.01
3.90
5.38
4.94
4.81
6.56
6.03
5.86
8.06
7.42
7.21
8.96
8.24
8.01
10.6
9.76
9.49

19.7
17.4
17.0
24.8
22.5
22.0
29.9
27.5
27.0
35.0
32.6
32.1
40.1
37.7
37.1
45.3
42.8
42.2
19.0
17.1
16.7
24.1
22.1
21.7
29.2
27.2
26.7
34.3
32.2
31.8
39.4
37.3
36.8
44.6
42.4
41.9

TC:Total Capacity(kW)
PI :Power Input(kW)

29

68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
68.6
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8
58.8

6.38
5.96
5.84
7.87
7.36
7.20
9.59
8.97
8.78
11.8
11.0
10.8
13.1
12.3
12.0
15.5
14.5
14.2
5.08
4.75
4.65
6.27
5.86
5.74
7.65
7.15
7.00
9.41
8.80
8.61
10.5
9.77
9.56
12.4
11.6
11.3

20.1
17.6
17.1
25.2
22.7
22.2
30.3
27.7
27.2
35.4
32.8
32.3
40.6
37.9
37.3
45.8
43.0
42.4
19.3
17.3
16.8
24.4
22.3
21.8
29.5
27.4
26.9
34.6
32.4
31.9
39.8
37.5
37.0
44.9
42.6
42.1

74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
74.7
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0
64.0

7.43
6.95
6.80
9.16
8.57
8.39
11.2
10.4
10.2
13.7
12.9
12.6
15.3
14.3
14.0
18.1
16.9
16.6
5.92
5.54
5.42
7.31
6.83
6.69
8.91
8.33
8.16
11.0
10.2
10.0
12.2
11.4
11.1
14.4
13.5
13.2

20.5
17.9
17.3
25.6
22.9
22.3
30.7
28.0
27.4
35.9
33.1
32.5
41.1
38.2
37.5
46.3
43.3
42.6
19.7
17.5
17.0
24.8
22.5
22.0
29.9
27.6
27.1
35.1
32.6
32.1
40.2
37.7
37.2
45.4
42.8
42.2

81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6

8.37
7.82
7.67
10.3
9.65
9.46
12.6
11.8
11.5
15.5
14.5
14.2
17.2
16.1
15.8
20.4
19.0
18.7
6.67
6.24
6.11
8.23
7.69
7.54
10.0
9.38
9.20
12.3
11.5
11.3
13.7
12.8
12.6
16.2
15.2
14.9

21.0
18.1
17.5
26.1
23.2
22.6
31.2
28.2
27.6
36.4
33.3
32.7
41.6
38.4
37.7
46.8
43.6
42.8
20.1
17.7
17.1
25.2
22.7
22.2
30.3
27.8
27.2
35.5
32.9
32.3
40.6
37.9
37.4
45.8
43.0
42.4

83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
83.6
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7
71.7

8.57
8.01
7.86
10.6
9.88
9.69
12.9
12.0
11.8
15.8
14.8
14.5
17.6
16.5
16.2
20.9
19.5
19.1
6.83
6.39
6.27
8.42
7.88
7.73
10.3
9.60
9.42
12.6
11.8
11.6
14.0
13.1
12.9
16.6
15.5
15.3

21.2
18.2
17.6
26.3
23.3
22.6
31.4
28.3
27.7
36.6
33.4
32.8
41.8
38.5
37.8
47.0
43.7
42.9
20.3
17.8
17.2
25.4
22.8
22.3
30.5
27.9
27.3
35.7
32.9
32.4
40.8
38.0
37.4
46.0
43.1
42.5

86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
86.9
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5
74.5

8.78
8.21
8.06
10.8
10.1
9.94
13.2
12.4
12.1
16.2
15.2
14.9
18.0
16.9
16.6
21.4
20.0
19.6
7.00
6.55
6.43
8.63
8.08
7.93
10.5
9.85
9.67
12.9
12.1
11.9
14.4
13.5
13.2
17.0
15.9
15.6

21.4
18.3
17.7
26.6
23.4
22.7
31.7
28.5
27.8
36.9
33.6
32.9
42.1
38.7
37.9
47.3
43.8
43.0
20.5
17.9
17.3
25.6
22.9
22.3
30.7
28.0
27.4
35.9
33.1
32.5
41.0
38.1
37.5
46.3
43.3
42.6

89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6
76.6

8.94
8.36
8.14
11.0
10.3
10.0
13.4
12.6
12.2
16.5
15.5
15.1
18.4
17.2
16.7
21.8
20.4
19.8
7.12
6.67
6.49
8.79
8.22
8.01
10.7
10.0
9.76
13.2
12.3
12.0
14.6
13.7
13.3
17.3
16.2
15.8

21.6
18.4
17.8
26.7
23.5
22.8
31.9
28.6
27.9
37.1
33.7
32.9
42.2
38.8
38.0
47.5
43.9
43.1
20.7
17.9
17.4
25.8
23.0
22.4
30.9
28.1
27.5
36.0
33.1
32.5
41.2
38.2
37.6
46.4
43.4
42.7

Combi. : Combination
Temp. : Temperature

Outdoor Units

Cooling Capacity
Indoor Air Temp.(CWB)
14
16
18
19
20
22
24
Inlet Water
Combi. Water Flow
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
Outlet
(%) Temp. Rate TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water TC PI Water
(C) (L/min) (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp. (kW) (kW) Temp.
(C)
(C)
(C)
(C)
(C)
(C)
(C)
15

20

25

50
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2
45.2

3.25
2.99
2.91
4.01
3.69
3.59
4.89
4.50
4.37
6.01
5.53
5.38
6.68
6.14
5.98
7.91
7.28
7.08

18.3
16.7
16.4
23.4
21.8
21.4
28.5
26.8
26.4
33.6
31.9
31.5
38.7
36.9
36.5
43.8
42.0
41.6

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0
49.0

3.79
3.54
3.47
4.68
4.37
4.28
5.70
5.33
5.22
7.01
6.56
6.42
7.79
7.29
7.13
9.23
8.63
8.44

18.6
16.9
16.5
23.7
21.9
21.5
28.8
27.0
26.6
33.9
32.0
31.6
39.0
37.1
36.7
44.1
42.1
41.7

53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4
53.4

4.42
4.13
4.04
5.45
5.09
4.99
6.64
6.21
6.08
8.17
7.64
7.48
9.08
8.49
8.31
10.8
10.1
9.85

18.9
17.1
16.6
24.0
22.1
21.7
29.1
27.1
26.7
34.2
32.2
31.8
39.3
37.3
36.8
44.5
42.3
41.9

58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0

4.97
4.65
4.56
6.13
5.73
5.62
7.48
6.99
6.86
9.20
8.60
8.43
10.2
9.56
9.37
12.1
11.3
11.1

19.3
17.2
16.8
24.4
22.3
21.8
29.5
27.3
26.9
34.6
32.4
31.9
39.7
37.5
37.0
44.9
42.5
42.0

59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7
59.7

5.09
4.76
4.67
6.28
5.87
5.76
7.66
7.16
7.03
9.42
8.81
8.64
10.5
9.79
9.60
12.4
11.6
11.4

19.4
17.3
16.8
24.5
22.3
21.9
29.6
27.4
26.9
34.7
32.5
32.0
39.8
37.5
37.0
45.0
42.6
42.1

62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1

5.22
4.88
4.79
6.43
6.02
5.91
7.85
7.34
7.21
9.65
9.03
8.86
10.7
10.0
9.85
12.7
11.9
11.7

19.6
17.4
16.9
24.7
22.4
21.9
29.8
27.5
27.0
34.9
32.6
32.0
40.0
37.6
37.1
45.2
42.7
42.2

63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8

5.31
4.97
4.84
6.55
6.13
5.97
7.99
7.48
7.28
9.83
9.20
8.95
10.9
10.2
9.95
12.9
12.1
11.8

19.7
17.5
17.0
24.8
22.5
22.0
29.9
27.6
27.0
35.0
32.6
32.1
40.2
37.7
37.2
45.4
42.8
42.2

Combi. : Combination
Temp. : Temperature

30

7.2 Heating capacity


Heating Capacity

ARWN100LA2
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

130
30

35

40

15

20

25

120
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

38.5
39.8
40.0
40.0
41.3
41.5
43.6
43.6
43.6
43.6
43.6
43.6
43.6
43.6
43.6
43.6
43.6
43.6
36.6
37.5
37.7
37.7
38.7
38.9
41.0
41.1
41.2
41.2
41.2
41.2
41.2
41.2
41.2
41.2
41.2
41.2

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

6.76
6.77
6.80
6.17
6.26
6.26
6.44
6.29
6.20
6.18
6.01
5.93
5.96
5.75
5.67
5.76
5.51
5.44
6.79
6.75
6.76
6.00
6.07
6.06
6.12
6.02
5.95
5.81
5.66
5.59
5.53
5.34
5.27
5.30
5.05
5.00

6.99
6.99
7.07
6.32
6.44
6.46
6.46
6.34
6.24
6.20
6.05
5.96
5.98
5.78
5.71
5.78
5.54
5.48
7.01
6.99
7.03
6.20
6.26
6.26
6.10
5.99
5.91
5.72
5.58
5.51
5.41
5.24
5.18
5.19
4.98
4.92

7.26
7.26
7.30
6.48
6.61
6.66
6.48
6.37
6.28
6.22
6.08
6.00
6.00
5.82
5.75
5.80
5.58
5.52
7.28
7.26
7.26
6.39
6.46
6.47
6.05
5.95
5.87
5.63
5.51
5.44
5.31
5.15
5.09
5.04
4.84
4.79

7.17
6.95
6.99
6.46
6.56
6.59
6.35
6.24
6.16
6.06
5.93
5.86
5.79
5.62
5.55
5.57
5.36
5.30
7.14
6.96
6.96
6.31
6.35
6.34
5.90
5.81
5.73
5.48
5.36
5.29
5.13
4.97
4.92
4.85
4.66
4.61

6.86
6.65
6.68
6.45
6.56
6.57
6.22
6.12
6.04
5.91
5.78
5.71
5.59
5.42
5.36
5.35
5.15
5.09
6.81
6.61
6.61
6.20
6.23
6.21
5.72
5.63
5.56
5.29
5.18
5.12
4.92
4.77
4.72
4.64
4.46
4.42

6.22
6.04
6.67
6.34
6.47
6.47
5.87
5.77
5.69
5.51
5.39
5.32
5.12
4.96
4.90
4.85
4.67
4.62
6.21
6.04
6.43
6.00
6.02
6.00
5.36
5.28
5.21
4.93
4.82
4.77
4.52
4.38
4.34
4.23
4.07
4.03

TC:Total Capacity(kW)
PI :Power Input(kW)

31

5.92
9.85
10.9
10.3
14.7
15.7
14.1
19.2
20.3
18.7
24.0
25.2
23.5
28.8
30.0
28.2
33.7
34.9
6.38
10.1
11.1
10.8
15.0
15.9
14.8
19.5
20.6
19.4
24.3
25.4
24.1
29.1
30.3
28.9
34.0
35.2

38.4
39.6
40.0
39.9
41.2
41.5
42.5
42.5
42.5
42.5
42.5
42.5
42.5
42.5
42.5
42.5
42.5
42.5
36.5
37.4
37.7
37.6
38.5
38.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8

5.95
9.87
10.9
10.4
14.7
15.7
14.4
19.3
20.4
19.0
24.1
25.3
23.8
29.0
30.2
28.5
33.8
35.1
6.40
10.2
11.1
10.9
15.1
16.0
15.0
19.7
20.7
19.7
24.5
25.6
24.5
29.3
30.5
29.2
34.2
35.4

38.3
39.5
40.0
39.8
41.0
41.5
41.5
41.5
41.5
41.5
41.5
41.5
41.5
41.5
41.5
41.5
41.5
41.5
36.4
37.2
37.5
37.4
38.2
38.5
38.5
38.5
38.5
38.5
38.5
38.5
38.5
38.5
38.5
38.5
38.5
38.5

5.98
9.89
10.9
10.4
14.7
15.7
14.6
19.5
20.5
19.3
24.3
25.4
24.0
29.1
30.3
28.8
34.0
35.2
6.42
10.2
11.1
11.0
15.1
16.0
15.4
19.9
20.8
20.0
24.7
25.7
24.8
29.5
30.6
29.6
34.4
35.5

37.3
38.5
38.9
38.7
39.9
40.3
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
40.7
35.5
36.3
36.6
36.4
37.3
37.5
37.7
37.7
37.7
37.7
37.7
37.7
37.7
37.7
37.7
37.7
37.7
37.7

6.21
10.0
11.0
10.7
14.9
15.8
14.8
19.6
20.6
19.5
24.4
25.5
24.3
29.2
30.4
29.0
34.1
35.3
6.64
10.3
11.2
11.2
15.2
16.1
15.6
20.0
20.9
20.2
24.8
25.8
25.0
29.6
30.7
29.8
34.5
35.6

36.3
37.4
37.9
37.6
38.9
39.2
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
39.8
34.4
35.1
35.4
35.2
36.1
36.3
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7
36.7

6.44
10.2
11.1
10.9
15.0
15.9
15.0
19.7
20.7
19.7
24.5
25.6
24.5
29.3
30.5
29.2
34.2
35.4
6.91
10.5
11.3
11.5
15.4
16.2
15.8
20.1
21.0
20.5
24.9
25.9
25.3
29.8
30.8
30.1
34.7
35.7

34.3
35.4
35.8
35.4
36.7
37.0
37.5
37.5
37.5
37.5
37.5
37.5
37.5
37.5
37.5
37.5
37.5
37.5
32.5
33.2
33.5
33.3
34.1
34.3
34.7
34.7
34.7
34.7
34.7
34.7
34.7
34.7
34.7
34.7
34.7
34.7

6.92
10.4
11.3
11.5
15.3
16.1
15.6
20.0
21.0
20.3
24.8
25.8
25.1
29.7
30.7
29.9
34.6
35.6
7.34
10.7
11.5
12.0
15.6
16.4
16.3
20.4
21.3
21.0
25.2
26.1
25.8
30.1
31.1
30.6
35.0
36.0

Combi. : Combination
Temp. : Temperature

Outdoor Units

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Combi. Water Flow
(%) Temp. Rate TC
(C) (L/min) (kW)

15

20

25

110
30

35

40

15

20

25

100
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

34.6
35.2
35.4
35.3
36.1
36.3
38.3
38.6
38.8
38.8
38.8
38.8
38.8
38.8
38.8
38.8
38.8
38.8
32.7
32.9
33.2
33.0
33.5
33.7
35.7
36.2
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

6.81
6.73
6.73
5.84
5.87
5.86
5.80
5.74
5.69
5.44
5.31
5.25
5.09
4.93
4.87
4.83
4.60
4.55
6.84
6.72
6.70
5.67
5.67
5.66
5.48
5.46
5.43
5.07
4.96
4.91
4.66
4.52
4.47
4.36
4.15
4.11

7.03
6.98
7.00
6.07
6.08
6.07
5.74
5.65
5.57
5.24
5.12
5.06
4.85
4.70
4.64
4.61
4.41
4.36
7.05
6.98
6.96
5.95
5.91
5.88
5.39
5.30
5.23
4.76
4.66
4.60
4.28
4.15
4.11
4.02
3.84
3.80

7.31
7.26
7.22
6.30
6.31
6.27
5.62
5.53
5.46
5.05
4.94
4.88
4.62
4.48
4.43
4.27
4.11
4.07
7.33
7.25
7.18
6.22
6.17
6.07
5.20
5.11
5.04
4.46
4.37
4.31
3.93
3.81
3.77
3.51
3.38
3.34

7.10
6.97
6.93
6.16
6.14
6.09
5.45
5.37
5.30
4.90
4.79
4.73
4.46
4.33
4.28
4.12
3.97
3.93
7.07
6.98
6.91
6.02
5.93
5.85
5.01
4.93
4.87
4.31
4.22
4.17
3.80
3.68
3.65
3.40
3.27
3.24

6.76
6.58
6.55
5.95
5.90
5.85
5.21
5.13
5.07
4.67
4.57
4.53
4.25
4.12
4.08
3.92
3.77
3.74
6.71
6.54
6.48
5.70
5.56
5.49
4.71
4.63
4.59
4.06
3.97
3.94
3.58
3.47
3.45
3.21
3.08
3.06

6.20
6.03
6.20
5.66
5.57
5.53
4.86
4.78
4.73
4.34
4.25
4.21
3.92
3.80
3.77
3.60
3.47
3.44
6.18
6.03
5.97
5.33
5.13
5.07
4.35
4.28
4.25
3.76
3.67
3.65
3.32
3.22
3.20
2.98
2.87
2.86

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

6.84
10.4
11.3
11.3
15.3
16.2
15.4
19.9
20.8
20.0
24.7
25.7
24.7
29.5
30.6
29.5
34.4
35.5
7.30
10.7
11.6
11.8
15.6
16.4
16.1
20.2
21.1
20.6
25.0
25.9
25.4
29.8
30.9
30.2
34.7
35.8

34.6
35.1
35.3
35.2
35.7
36.0
37.1
37.1
37.1
37.1
37.1
37.1
37.1
37.1
37.1
37.1
37.1
37.1
32.7
32.8
33.0
32.9
33.0
33.3
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4

6.85
10.5
11.3
11.5
15.4
16.2
15.7
20.1
21.0
20.4
24.9
25.9
25.2
29.7
30.8
30.0
34.6
35.7
7.30
10.8
11.6
12.1
15.7
16.5
16.4
20.4
21.3
21.1
25.3
26.2
25.9
30.1
31.1
30.7
35.0
36.0

34.5
34.9
35.1
35.0
35.4
35.6
35.6
35.6
35.6
35.6
35.6
35.6
35.6
35.6
35.6
35.6
35.6
35.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6

6.87
10.5
11.4
11.6
15.4
16.3
16.1
20.3
21.2
20.8
25.1
26.0
25.6
29.9
31.0
30.4
34.8
35.9
7.32
10.8
11.6
12.1
15.8
16.6
16.9
20.7
21.5
21.6
25.5
26.4
26.4
30.4
31.3
31.2
35.3
36.2

33.7
34.1
34.2
34.1
34.6
34.7
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9

7.06
10.6
11.5
11.8
15.6
16.4
16.3
20.4
21.3
21.0
25.2
26.1
25.8
30.1
31.0
30.6
34.9
36.0
7.49
10.9
11.7
12.3
15.9
16.7
17.0
20.8
21.6
21.8
25.6
26.5
26.6
30.5
31.4
31.4
35.4
36.3

32.4
32.8
32.9
32.8
33.2
33.4
33.6
33.6
33.6
33.6
33.6
33.6
33.6
33.6
33.6
33.6
33.6
33.6
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4

7.37
10.8
11.6
12.1
15.7
16.5
16.6
20.5
21.4
21.3
25.4
26.3
26.1
30.2
31.2
30.9
35.1
36.1
7.83
11.1
11.8
12.7
16.1
16.8
17.4
20.9
21.7
22.1
25.8
26.6
27.0
30.7
31.5
31.8
35.6
36.5

30.8
31.1
31.3
31.1
31.6
31.7
31.8
31.8
31.8
31.8
31.8
31.8
31.8
31.8
31.8
31.8
31.8
31.8
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0

7.75
11.0
11.8
12.5
15.9
16.7
17.0
20.8
21.6
21.8
25.6
26.5
26.6
30.5
31.4
31.4
35.4
36.3
8.17
11.2
12.0
13.0
16.3
17.0
17.8
21.1
21.9
22.5
26.0
26.8
27.3
30.9
31.7
32.2
35.8
36.6

Combi. : Combination
Temp. : Temperature

32

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

90
30

35

40

15

20

25

80
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

30.9
31.0
31.2
31.1
31.3
31.4
32.4
32.7
32.8
32.8
32.8
32.8
32.8
32.8
32.8
32.8
32.8
32.8
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2
29.2

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

6.26
6.11
6.08
5.22
5.17
5.14
4.86
4.80
4.77
4.45
4.34
4.30
4.07
3.95
3.92
3.80
3.63
3.60
5.68
5.50
5.45
4.77
4.66
4.62
4.24
4.14
4.10
3.83
3.73
3.70
3.49
3.39
3.36
3.24
3.11
3.08

6.22
6.12
6.09
5.28
5.21
5.17
4.71
4.62
4.57
4.18
4.08
4.03
3.76
3.65
3.61
3.52
3.37
3.34
5.40
5.27
5.22
4.61
4.51
4.46
4.03
3.94
3.90
3.59
3.50
3.47
3.24
3.15
3.12
3.01
2.90
2.88

6.25
6.16
6.10
5.34
5.27
5.20
4.52
4.43
4.38
3.92
3.83
3.78
3.47
3.37
3.33
3.12
3.00
2.98
5.18
5.06
5.02
4.47
4.37
4.32
3.84
3.75
3.71
3.37
3.28
3.25
3.01
2.92
2.89
2.72
2.63
2.61

6.03
5.93
5.87
5.17
5.08
5.01
4.36
4.28
4.24
3.79
3.70
3.67
3.36
3.26
3.23
3.03
2.91
2.89
4.99
4.88
4.84
4.32
4.23
4.18
3.72
3.63
3.60
3.27
3.19
3.16
2.93
2.84
2.82
2.65
2.56
2.54

5.72
5.57
5.52
4.89
4.78
4.72
4.11
4.03
4.00
3.58
3.49
3.47
3.18
3.08
3.06
2.86
2.75
2.74
4.72
4.60
4.56
4.09
3.99
3.95
3.51
3.44
3.41
3.09
3.02
3.00
2.77
2.69
2.68
2.51
2.43
2.42

5.29
5.15
5.10
4.58
4.42
4.37
3.82
3.75
3.72
3.33
3.25
3.23
2.96
2.87
2.86
2.67
2.57
2.57
4.39
4.27
4.23
3.84
3.71
3.68
3.28
3.21
3.19
2.90
2.83
2.81
2.60
2.52
2.52
2.36
2.28
2.28

TC:Total Capacity(kW)
PI :Power Input(kW)

33

7.72
11.0
11.8
12.4
15.9
16.7
16.9
20.7
21.5
21.5
25.5
26.3
26.3
30.3
31.3
31.1
35.2
36.2
8.13
11.2
12.0
13.0
16.2
17.0
17.7
21.1
21.9
22.5
26.0
26.8
27.3
30.9
31.7
32.1
35.8
36.6

30.1
30.2
30.3
30.2
30.3
30.4
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
31.0
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5

7.91
11.1
11.9
12.7
16.1
16.8
17.3
20.9
21.7
22.0
25.7
26.6
26.8
30.6
31.5
31.6
35.5
36.4
8.52
11.4
12.2
13.4
16.5
17.1
18.1
21.3
22.0
22.9
26.2
26.9
27.7
31.1
31.9
32.6
36.0
36.8

29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
29.3
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1

8.09
11.2
12.0
12.9
16.2
16.9
17.7
21.1
21.8
22.4
26.0
26.7
27.2
30.8
31.7
32.1
35.7
36.6
8.86
11.6
12.3
13.7
16.6
17.3
18.5
21.5
22.2
23.3
26.4
27.1
28.1
31.3
32.0
33.0
36.2
37.0

28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
28.7
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5

8.24
11.3
12.0
13.1
16.3
17.0
17.8
21.2
21.9
22.6
26.1
26.8
27.4
30.9
31.7
32.3
35.8
36.7
8.99
11.7
12.4
13.8
16.7
17.3
18.6
21.6
22.3
23.4
26.5
27.2
28.3
31.4
32.1
33.1
36.3
37.0

27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
27.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4

8.55
11.5
12.2
13.4
16.5
17.1
18.2
21.4
22.0
22.9
26.2
27.0
27.8
31.1
31.9
32.6
36.0
36.8
9.26
11.8
12.5
14.1
16.9
17.5
18.9
21.8
22.4
23.7
26.6
27.3
28.6
31.5
32.2
33.4
36.5
37.2

26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
26.1
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2
23.2

8.85
11.6
12.3
13.7
16.6
17.3
18.5
21.5
22.2
23.3
26.4
27.1
28.1
31.3
32.0
33.0
36.2
37.0
9.54
12.0
12.6
14.4
17.0
17.6
19.2
21.9
22.5
24.0
26.8
27.4
28.9
31.7
32.4
33.7
36.6
37.3

Combi. : Combination
Temp. : Temperature

Outdoor Units

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Combi. Water Flow
(%) Temp. Rate TC
(C) (L/min) (kW)

15

20

25

70
30

35

40

15

20

25

60
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9
21.9

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

4.86
4.70
4.66
4.11
4.01
3.97
3.65
3.56
3.53
3.29
3.20
3.17
2.99
2.90
2.88
2.77
2.66
2.64
4.04
3.90
3.86
3.45
3.35
3.32
3.06
2.97
2.95
2.75
2.67
2.65
2.50
2.42
2.40
2.29
2.22
2.20

4.59
4.46
4.42
3.93
3.84
3.80
3.46
3.37
3.34
3.08
3.00
2.97
2.79
2.70
2.68
2.58
2.49
2.47
3.78
3.66
3.63
3.26
3.17
3.14
2.88
2.80
2.77
2.57
2.50
2.48
2.33
2.26
2.25
2.15
2.08
2.07

4.37
4.26
4.22
3.78
3.69
3.66
3.28
3.20
3.17
2.90
2.82
2.79
2.60
2.52
2.50
2.36
2.28
2.26
3.57
3.46
3.43
3.10
3.01
2.99
2.72
2.64
2.62
2.42
2.35
2.33
2.18
2.12
2.10
1.99
1.93
1.92

4.21
4.11
4.08
3.66
3.57
3.54
3.18
3.10
3.07
2.81
2.74
2.72
2.53
2.45
2.44
2.30
2.22
2.21
3.44
3.34
3.31
3.00
2.92
2.90
2.64
2.57
2.55
2.35
2.29
2.27
2.13
2.07
2.05
1.94
1.88
1.87

3.98
3.88
3.84
3.47
3.38
3.35
3.00
2.94
2.92
2.67
2.60
2.58
2.40
2.33
2.32
2.19
2.11
2.10
3.24
3.16
3.13
2.84
2.77
2.74
2.50
2.44
2.42
2.24
2.18
2.17
2.03
1.97
1.96
1.86
1.80
1.79

3.71
3.61
3.57
3.26
3.15
3.13
2.82
2.75
2.73
2.51
2.44
2.43
2.26
2.19
2.19
2.06
1.99
1.99
3.02
2.95
2.92
2.67
2.59
2.57
2.35
2.29
2.28
2.11
2.05
2.05
1.92
1.86
1.86
1.76
1.70
1.70

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

8.99
11.7
12.4
13.8
16.7
17.3
18.6
21.6
22.3
23.4
26.5
27.2
28.3
31.4
32.1
33.1
36.3
37.0
9.85
12.2
12.7
14.7
17.2
17.7
19.5
22.1
22.6
24.3
27.0
27.6
29.2
31.9
32.5
34.1
36.8
37.5

24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6
20.6

9.33
11.9
12.5
14.2
16.9
17.5
19.0
21.8
22.4
23.8
26.7
27.3
28.6
31.6
32.3
33.5
36.5
37.2
10.1
12.3
12.9
15.0
17.3
17.9
19.8
22.3
22.8
24.7
27.2
27.7
29.5
32.1
32.7
34.4
37.0
37.6

22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
22.8
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6

9.62
12.0
12.6
14.5
17.1
17.6
19.3
22.0
22.5
24.1
26.9
27.5
29.0
31.8
32.4
33.8
36.7
37.4
10.4
12.5
13.0
15.3
17.5
18.0
20.1
22.4
22.9
24.9
27.3
27.8
29.8
32.2
32.8
34.7
37.2
37.7

22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
22.3
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1
19.1

9.74
12.1
12.7
14.6
17.1
17.7
19.4
22.0
22.6
24.2
26.9
27.5
29.1
31.8
32.5
34.0
36.8
37.4
10.5
12.5
13.0
15.4
17.5
18.0
20.2
22.5
22.9
25.1
27.4
27.9
29.9
32.3
32.8
34.8
37.2
37.8

21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
21.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3
18.3

9.98
12.2
12.8
14.9
17.3
17.8
19.7
22.2
22.7
24.5
27.1
27.6
29.4
32.0
32.6
34.2
36.9
37.5
10.7
12.6
13.1
15.6
17.7
18.1
20.4
22.6
23.0
25.3
27.5
28.0
30.2
32.4
32.9
35.1
37.3
37.9

20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4
17.4

10.2
12.4
12.9
15.1
17.4
17.9
19.9
22.3
22.8
24.8
27.2
27.7
29.6
32.1
32.7
34.5
37.1
37.6
10.9
12.7
13.2
15.8
17.8
18.2
20.7
22.7
23.1
25.5
27.6
28.1
30.4
32.5
33.0
35.3
37.5
38.0

Combi. : Combination
Temp. : Temperature

34

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

50
30

35

40

50
96
120
50
96
120
50
96
120
50
96
120
50
96
120
50
96
120

18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

3.21
3.09
3.07
2.79
2.69
2.67
2.46
2.38
2.37
2.21
2.14
2.12
2.00
1.94
1.93
1.82
1.77
1.76

2.97
2.86
2.84
2.59
2.50
2.48
2.30
2.22
2.21
2.07
2.00
1.99
1.88
1.82
1.81
1.72
1.67
1.66

2.76
2.65
2.63
2.42
2.34
2.32
2.16
2.09
2.07
1.94
1.88
1.87
1.77
1.72
1.71
1.62
1.58
1.57

2.66
2.57
2.55
2.34
2.27
2.25
2.10
2.03
2.02
1.90
1.84
1.83
1.73
1.68
1.67
1.59
1.55
1.54

2.50
2.44
2.41
2.22
2.16
2.14
1.99
1.94
1.93
1.81
1.76
1.75
1.66
1.61
1.60
1.53
1.48
1.48

2.34
2.28
2.26
2.09
2.03
2.02
1.89
1.83
1.82
1.72
1.67
1.66
1.58
1.53
1.53
1.46
1.42
1.42

TC:Total Capacity(kW)
PI :Power Input(kW)

35

10.7
12.6
13.1
15.6
17.7
18.1
20.4
22.6
23.0
25.3
27.5
28.0
30.2
32.4
32.9
35.1
37.4
37.9

17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2
17.2

10.9
12.8
13.2
15.8
17.8
18.2
20.7
22.7
23.1
25.6
27.6
28.1
30.5
32.6
33.0
35.4
37.5
38.0

16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3
16.3

11.2
12.9
13.3
16.1
17.9
18.3
20.9
22.8
23.2
25.8
27.8
28.2
30.7
32.7
33.1
35.6
37.6
38.1

15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9
15.9

11.2
12.9
13.3
16.2
17.9
18.3
21.0
22.9
23.3
25.9
27.8
28.2
30.8
32.7
33.2
35.7
37.7
38.1

15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2

11.4
13.0
13.4
16.3
18.0
18.4
21.2
23.0
23.4
26.1
27.9
28.3
31.0
32.8
33.3
35.9
37.8
38.2

14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5

11.6
13.1
13.5
16.5
18.1
18.5
21.4
23.1
23.4
26.3
28.0
28.4
31.2
32.9
33.4
36.1
37.9
38.3

Combi. : Combination
Temp. : Temperature

Outdoor Units

ARWN200LA2
Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

130
30

35

40

15

20

25

120
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

77.1
79.6
79.9
80.0
82.6
83.0
87.1
87.1
87.1
87.1
87.1
87.1
87.1
87.1
87.1
87.1
87.1
87.1
73.2
75.0
75.4
75.3
77.4
77.8
81.9
82.2
82.4
82.4
82.4
82.4
82.4
82.4
82.4
82.4
82.4
82.4

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

12.1
12.1
12.1
11.0
11.2
11.2
11.5
11.2
11.1
11.0
10.7
10.6
10.7
10.3
10.1
10.3
9.84
9.72
12.1
12.1
12.1
10.7
10.8
10.8
10.9
10.7
10.6
10.4
10.1
9.98
9.87
9.53
9.42
9.46
9.03
8.93

12.4
12.4
12.6
11.2
11.4
11.5
11.5
11.3
11.1
11.0
10.7
10.6
10.6
10.3
10.1
10.3
9.85
9.73
12.5
12.4
12.5
11.0
11.1
11.1
10.8
10.6
10.5
10.2
9.92
9.79
9.62
9.31
9.19
9.23
8.84
8.74

12.9
12.9
13.0
11.5
11.7
11.8
11.5
11.3
11.2
11.0
10.8
10.7
10.7
10.3
10.2
10.3
9.90
9.80
12.9
12.9
12.9
11.4
11.5
11.5
10.7
10.6
10.4
10.0
9.79
9.66
9.43
9.15
9.04
8.94
8.60
8.51

12.7
12.4
12.4
11.5
11.6
11.7
11.3
11.1
10.9
10.8
10.5
10.4
10.3
9.98
9.86
9.89
9.52
9.41
12.7
12.4
12.4
11.2
11.3
11.3
10.5
10.3
10.2
9.73
9.52
9.40
9.11
8.83
8.73
8.61
8.28
8.19

12.2
11.8
11.9
11.5
11.7
11.7
11.1
10.9
10.7
10.5
10.3
10.1
9.93
9.63
9.52
9.50
9.14
9.04
12.1
11.7
11.7
11.0
11.1
11.0
10.2
10.0
9.87
9.40
9.20
9.09
8.74
8.48
8.39
8.23
7.92
7.84

11.1
10.7
11.8
11.3
11.5
11.5
10.4
10.3
10.1
9.79
9.58
9.45
9.09
8.81
8.71
8.62
8.29
8.20
11.0
10.7
11.4
10.7
10.7
10.7
9.52
9.37
9.26
8.75
8.56
8.46
8.02
7.78
7.70
7.51
7.22
7.16

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

5.92
9.85
10.9
10.3
14.7
15.7
14.1
19.2
20.3
18.7
24.0
25.2
23.5
28.8
30.0
28.2
33.7
34.9
6.38
10.1
11.1
10.8
15.0
15.9
14.8
19.5
20.6
19.4
24.3
25.4
24.1
29.1
30.3
28.9
34.0
35.2

76.9
79.3
79.9
79.8
82.3
83.0
85.1
85.1
85.1
85.1
85.1
85.1
85.1
85.1
85.1
85.1
85.1
85.1
73.0
74.7
75.3
75.1
76.9
77.5
79.6
79.6
79.6
79.6
79.6
79.6
79.6
79.6
79.6
79.6
79.6
79.6

5.95
9.87
10.9
10.4
14.7
15.7
14.4
19.3
20.4
19.0
24.1
25.3
23.8
29.0
30.2
28.5
33.8
35.1
6.40
10.2
11.1
10.9
15.1
16.0
15.0
19.7
20.7
19.7
24.5
25.6
24.5
29.3
30.5
29.2
34.2
35.4

76.6
79.0
79.9
79.5
82.0
83.0
83.0
83.0
83.0
83.0
83.0
83.0
83.0
83.0
83.0
83.0
83.0
83.0
72.8
74.4
75.0
74.8
76.4
77.1
77.1
77.1
77.1
77.1
77.1
77.1
77.1
77.1
77.1
77.1
77.1
77.1

5.98
9.89
10.9
10.4
14.7
15.7
14.6
19.5
20.5
19.3
24.3
25.4
24.0
29.1
30.3
28.8
34.0
35.2
6.42
10.2
11.1
11.0
15.1
16.0
15.4
19.9
20.8
20.0
24.7
25.7
24.8
29.5
30.6
29.6
34.4
35.5

74.6
76.9
77.9
77.3
79.9
80.7
81.3
81.3
81.3
81.3
81.3
81.3
81.3
81.3
81.3
81.3
81.3
81.3
71.0
72.5
73.2
72.8
74.5
75.0
75.5
75.5
75.5
75.5
75.5
75.5
75.5
75.5
75.5
75.5
75.5
75.5

6.21
10.0
11.0
10.7
14.9
15.8
14.8
19.6
20.6
19.5
24.4
25.5
24.3
29.2
30.4
29.0
34.1
35.3
6.64
10.3
11.2
11.2
15.2
16.1
15.6
20.0
20.9
20.2
24.8
25.8
25.0
29.6
30.7
29.8
34.5
35.6

72.6
74.9
75.8
75.3
77.7
78.4
79.7
79.7
79.7
79.7
79.7
79.7
79.7
79.7
79.7
79.7
79.7
79.7
68.7
70.2
70.8
70.5
72.1
72.6
73.4
73.4
73.4
73.4
73.4
73.4
73.4
73.4
73.4
73.4
73.4
73.4

6.44
10.2
11.1
10.9
15.0
15.9
15.0
19.7
20.7
19.7
24.5
25.6
24.5
29.3
30.5
29.2
34.2
35.4
6.91
10.5
11.3
11.5
15.4
16.2
15.8
20.1
21.0
20.5
24.9
25.9
25.3
29.8
30.8
30.1
34.7
35.7

68.6
70.7
71.6
70.8
73.4
74.0
75.0
75.0
75.0
75.0
75.0
75.0
75.0
75.0
75.0
75.0
75.0
75.0
65.1
66.5
67.0
66.5
68.3
68.7
69.3
69.3
69.3
69.3
69.3
69.3
69.3
69.3
69.3
69.3
69.3
69.3

6.92
10.4
11.3
11.5
15.3
16.1
15.6
20.0
21.0
20.3
24.8
25.8
25.1
29.7
30.7
29.9
34.6
35.6
7.34
10.7
11.5
12.0
15.6
16.4
16.3
20.4
21.3
21.0
25.2
26.1
25.8
30.1
31.1
30.6
35.0
36.0

Combi. : Combination
Temp. : Temperature

36

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Combi. Water Flow
(%) Temp. Rate TC
(C) (L/min) (kW)

15

20

25

110
30

35

40

15

20

25

100
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

69.3
70.4
70.9
70.7
72.2
72.6
76.7
77.3
77.6
77.6
77.6
77.6
77.6
77.6
77.6
77.6
77.6
77.6
65.4
65.9
66.3
66.0
67.0
67.5
71.4
72.4
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

12.2
12.0
12.0
10.4
10.5
10.5
10.4
10.2
10.2
9.72
9.48
9.37
9.09
8.80
8.70
8.63
8.22
8.13
12.2
12.0
12.0
10.1
10.1
10.1
9.78
9.75
9.71
9.06
8.86
8.76
8.32
8.07
7.99
7.80
7.41
7.34

12.5
12.4
12.4
10.8
10.8
10.8
10.2
10.0
9.89
9.31
9.10
8.98
8.61
8.34
8.25
8.19
7.83
7.75
12.5
12.4
12.4
10.6
10.5
10.4
9.57
9.41
9.29
8.46
8.27
8.18
7.61
7.38
7.30
7.15
6.83
6.76

13.0
12.9
12.8
11.2
11.2
11.1
9.99
9.83
9.69
8.97
8.77
8.66
8.20
7.96
7.86
7.59
7.30
7.22
13.0
12.9
12.8
11.0
11.0
10.8
9.23
9.08
8.96
7.93
7.76
7.66
6.98
6.77
6.69
6.24
6.00
5.94

12.6
12.4
12.3
10.9
10.9
10.8
9.69
9.53
9.41
8.70
8.50
8.41
7.93
7.69
7.61
7.32
7.05
6.98
12.6
12.4
12.3
10.7
10.5
10.4
8.90
8.75
8.65
7.66
7.49
7.41
6.75
6.54
6.48
6.04
5.81
5.76

12.0
11.7
11.6
10.6
10.5
10.4
9.26
9.11
9.01
8.30
8.12
8.04
7.55
7.32
7.25
6.96
6.70
6.64
11.9
11.6
11.5
10.1
9.88
9.75
8.36
8.23
8.15
7.21
7.05
6.99
6.35
6.16
6.12
5.69
5.48
5.44

11.0
10.7
11.0
10.1
9.90
9.83
8.63
8.49
8.40
7.71
7.54
7.48
6.96
6.75
6.70
6.40
6.16
6.11
11.0
10.7
10.6
9.46
9.10
9.00
7.73
7.61
7.55
6.67
6.53
6.49
5.90
5.72
5.69
5.29
5.09
5.07

TC:Total Capacity(kW)
PI :Power Input(kW)

37

6.84
10.4
11.3
11.3
15.3
16.2
15.4
19.9
20.8
20.0
24.7
25.7
24.7
29.5
30.6
29.5
34.4
35.5
7.30
10.7
11.6
11.8
15.6
16.4
16.1
20.2
21.1
20.6
25.0
25.9
25.4
29.8
30.9
30.2
34.7
35.8

69.2
70.2
70.7
70.5
71.5
72.0
74.2
74.2
74.2
74.2
74.2
74.2
74.2
74.2
74.2
74.2
74.2
74.2
65.4
65.6
66.1
65.9
66.1
66.6
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8

6.85
10.5
11.3
11.5
15.4
16.2
15.7
20.1
21.0
20.4
24.9
25.9
25.2
29.7
30.8
30.0
34.6
35.7
7.30
10.8
11.6
12.1
15.7
16.5
16.4
20.4
21.3
21.1
25.3
26.2
25.9
30.1
31.1
30.7
35.0
36.0

69.0
69.8
70.1
70.0
70.8
71.1
71.1
71.1
71.1
71.1
71.1
71.1
71.1
71.1
71.1
71.1
71.1
71.1
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2

6.87
10.5
11.4
11.6
15.4
16.3
16.1
20.3
21.2
20.8
25.1
26.0
25.6
29.9
31.0
30.4
34.8
35.9
7.32
10.8
11.6
12.1
15.8
16.6
16.9
20.7
21.5
21.6
25.5
26.4
26.4
30.4
31.3
31.2
35.3
36.2

67.4
68.2
68.5
68.3
69.1
69.4
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8

7.06
10.6
11.5
11.8
15.6
16.4
16.3
20.4
21.3
21.0
25.2
26.1
25.8
30.1
31.0
30.6
34.9
36.0
7.49
10.9
11.7
12.3
15.9
16.7
17.0
20.8
21.6
21.8
25.6
26.5
26.6
30.5
31.4
31.4
35.4
36.3

64.8
65.5
65.8
65.7
66.5
66.7
67.1
67.1
67.1
67.1
67.1
67.1
67.1
67.1
67.1
67.1
67.1
67.1
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9

7.37
10.8
11.6
12.1
15.7
16.5
16.6
20.5
21.4
21.3
25.4
26.3
26.1
30.2
31.2
30.9
35.1
36.1
7.83
11.1
11.8
12.7
16.1
16.8
17.4
20.9
21.7
22.1
25.8
26.6
27.0
30.7
31.5
31.8
35.6
36.5

61.5
62.2
62.5
62.3
63.1
63.3
63.7
63.7
63.7
63.7
63.7
63.7
63.7
63.7
63.7
63.7
63.7
63.7
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0

7.75
11.0
11.8
12.5
15.9
16.7
17.0
20.8
21.6
21.8
25.6
26.5
26.6
30.5
31.4
31.4
35.4
36.3
8.17
11.2
12.0
13.0
16.3
17.0
17.8
21.1
21.9
22.5
26.0
26.8
27.3
30.9
31.7
32.2
35.8
36.6

Combi. : Combination
Temp. : Temperature

Outdoor Units

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

90
30

35

40

15

20

25

80
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

61.8
62.1
62.3
62.2
62.6
62.9
64.9
65.3
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

11.2
10.9
10.9
9.33
9.23
9.18
8.68
8.58
8.52
7.95
7.76
7.68
7.28
7.06
7.00
6.79
6.48
6.42
10.1
9.83
9.74
8.53
8.33
8.26
7.58
7.40
7.33
6.84
6.66
6.60
6.24
6.05
6.00
5.78
5.55
5.51

11.1
10.9
10.8
9.38
9.25
9.18
8.37
8.20
8.11
7.42
7.24
7.17
6.68
6.48
6.42
6.25
5.99
5.93
9.59
9.35
9.27
8.18
8.00
7.93
7.16
6.99
6.93
6.38
6.21
6.16
5.76
5.59
5.54
5.35
5.15
5.11

11.1
10.9
10.8
9.49
9.36
9.24
8.03
7.87
7.77
6.96
6.79
6.72
6.16
5.98
5.91
5.54
5.34
5.29
9.20
8.99
8.91
7.93
7.77
7.68
6.82
6.66
6.59
5.99
5.83
5.78
5.35
5.19
5.14
4.84
4.67
4.63

10.7
10.5
10.4
9.18
9.02
8.91
7.75
7.60
7.52
6.73
6.57
6.51
5.97
5.79
5.74
5.37
5.18
5.14
8.87
8.68
8.60
7.68
7.51
7.43
6.60
6.45
6.39
5.81
5.66
5.61
5.20
5.04
5.00
4.71
4.54
4.51

10.2
9.90
9.80
8.69
8.48
8.38
7.30
7.16
7.11
6.35
6.20
6.16
5.64
5.47
5.44
5.08
4.89
4.87
8.39
8.18
8.10
7.27
7.08
7.01
6.24
6.10
6.06
5.50
5.36
5.33
4.93
4.78
4.75
4.47
4.31
4.29

9.39
9.15
9.06
8.14
7.85
7.77
6.78
6.65
6.61
5.91
5.77
5.74
5.26
5.10
5.08
4.75
4.57
4.56
7.79
7.59
7.52
6.82
6.60
6.53
5.83
5.70
5.66
5.15
5.02
5.00
4.62
4.48
4.47
4.20
4.05
4.04

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

7.72
11.0
11.8
12.4
15.9
16.7
16.9
20.7
21.5
21.5
25.5
26.3
26.3
30.3
31.3
31.1
35.2
36.2
8.13
11.2
12.0
13.0
16.2
17.0
17.7
21.1
21.9
22.5
26.0
26.8
27.3
30.9
31.7
32.1
35.8
36.6

60.2
60.3
60.5
60.4
60.6
60.8
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0

7.91
11.1
11.9
12.7
16.1
16.8
17.3
20.9
21.7
22.0
25.7
26.6
26.8
30.6
31.5
31.6
35.5
36.4
8.52
11.4
12.2
13.4
16.5
17.1
18.1
21.3
22.0
22.9
26.2
26.9
27.7
31.1
31.9
32.6
36.0
36.8

58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2

8.09
11.2
12.0
12.9
16.2
16.9
17.7
21.1
21.8
22.4
26.0
26.7
27.2
30.8
31.7
32.1
35.7
36.6
8.86
11.6
12.3
13.7
16.6
17.3
18.5
21.5
22.2
23.3
26.4
27.1
28.1
31.3
32.0
33.0
36.2
37.0

57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0

8.24
11.3
12.0
13.1
16.3
17.0
17.8
21.2
21.9
22.6
26.1
26.8
27.4
30.9
31.7
32.3
35.8
36.7
8.99
11.7
12.4
13.8
16.7
17.3
18.6
21.6
22.3
23.4
26.5
27.2
28.3
31.4
32.1
33.1
36.3
37.0

54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7
48.7

8.55
11.5
12.2
13.4
16.5
17.1
18.2
21.4
22.0
22.9
26.2
27.0
27.8
31.1
31.9
32.6
36.0
36.8
9.26
11.8
12.5
14.1
16.9
17.5
18.9
21.8
22.4
23.7
26.6
27.3
28.6
31.5
32.2
33.4
36.5
37.2

52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4
46.4

8.85
11.6
12.3
13.7
16.6
17.3
18.5
21.5
22.2
23.3
26.4
27.1
28.1
31.3
32.0
33.0
36.2
37.0
9.54
12.0
12.6
14.4
17.0
17.6
19.2
21.9
22.5
24.0
26.8
27.4
28.9
31.7
32.4
33.7
36.6
37.3

Combi. : Combination
Temp. : Temperature

38

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Combi. Water Flow
(%) Temp. Rate TC
(C) (L/min) (kW)

15

20

25

70
30

35

40

15

20

25

60
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
51.0
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

8.67
8.39
8.32
7.34
7.15
7.10
6.52
6.35
6.30
5.87
5.71
5.67
5.35
5.19
5.15
4.94
4.75
4.72
7.21
6.96
6.90
6.16
5.98
5.94
5.46
5.30
5.26
4.90
4.76
4.73
4.46
4.32
4.30
4.10
3.96
3.93

8.15
7.93
7.86
6.99
6.82
6.75
6.14
5.98
5.93
5.48
5.33
5.28
4.95
4.80
4.76
4.58
4.42
4.39
6.71
6.50
6.45
5.80
5.63
5.58
5.11
4.97
4.93
4.57
4.44
4.41
4.14
4.02
3.99
3.82
3.69
3.67

7.77
7.56
7.50
6.72
6.56
6.49
5.83
5.68
5.62
5.14
5.00
4.96
4.61
4.48
4.44
4.19
4.05
4.02
6.33
6.14
6.09
5.51
5.35
5.31
4.83
4.69
4.65
4.30
4.17
4.14
3.88
3.76
3.74
3.54
3.43
3.40

7.49
7.31
7.24
6.51
6.35
6.29
5.64
5.51
5.46
5.00
4.86
4.83
4.49
4.35
4.33
4.08
3.94
3.92
6.10
5.94
5.89
5.33
5.19
5.15
4.68
4.56
4.52
4.18
4.06
4.04
3.78
3.67
3.65
3.45
3.34
3.33

7.07
6.89
6.83
6.16
6.00
5.94
5.34
5.21
5.18
4.74
4.61
4.59
4.26
4.14
4.12
3.88
3.75
3.74
5.76
5.61
5.56
5.05
4.92
4.87
4.44
4.33
4.30
3.97
3.87
3.85
3.60
3.49
3.48
3.30
3.19
3.18

6.58
6.41
6.35
5.78
5.60
5.55
5.00
4.89
4.86
4.45
4.33
4.32
4.02
3.90
3.89
3.66
3.54
3.53
5.37
5.23
5.18
4.75
4.61
4.57
4.18
4.07
4.05
3.75
3.65
3.64
3.41
3.31
3.30
3.13
3.03
3.02

TC:Total Capacity(kW)
PI :Power Input(kW)

39

8.99
11.7
12.4
13.8
16.7
17.3
18.6
21.6
22.3
23.4
26.5
27.2
28.3
31.4
32.1
33.1
36.3
37.0
9.85
12.2
12.7
14.7
17.2
17.7
19.5
22.1
22.6
24.3
27.0
27.6
29.2
31.9
32.5
34.1
36.8
37.5

48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
48.2
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3

9.33
11.9
12.5
14.2
16.9
17.5
19.0
21.8
22.4
23.8
26.7
27.3
28.6
31.6
32.3
33.5
36.5
37.2
10.1
12.3
12.9
15.0
17.3
17.9
19.8
22.3
22.8
24.7
27.2
27.7
29.5
32.1
32.7
34.4
37.0
37.6

45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
45.6
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1
39.1

9.62
12.0
12.6
14.5
17.1
17.6
19.3
22.0
22.5
24.1
26.9
27.5
29.0
31.8
32.4
33.8
36.7
37.4
10.4
12.5
13.0
15.3
17.5
18.0
20.1
22.4
22.9
24.9
27.3
27.8
29.8
32.2
32.8
34.7
37.2
37.7

44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
44.6
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3
38.3

9.74
12.1
12.7
14.6
17.1
17.7
19.4
22.0
22.6
24.2
26.9
27.5
29.1
31.8
32.5
34.0
36.8
37.4
10.5
12.5
13.0
15.4
17.5
18.0
20.2
22.5
22.9
25.1
27.4
27.9
29.9
32.3
32.8
34.8
37.2
37.8

42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
42.6
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5
36.5

9.98
12.2
12.8
14.9
17.3
17.8
19.7
22.2
22.7
24.5
27.1
27.6
29.4
32.0
32.6
34.2
36.9
37.5
10.7
12.6
13.1
15.6
17.7
18.1
20.4
22.6
23.0
25.3
27.5
28.0
30.2
32.4
32.9
35.1
37.3
37.9

40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
40.6
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8
34.8

10.2
12.4
12.9
15.1
17.4
17.9
19.9
22.3
22.8
24.8
27.2
27.7
29.6
32.1
32.7
34.5
37.1
37.6
10.9
12.7
13.2
15.8
17.8
18.2
20.7
22.7
23.1
25.5
27.6
28.1
30.4
32.5
33.0
35.3
37.5
38.0

Combi. : Combination
Temp. : Temperature

Outdoor Units

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

50
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

5.74
5.53
5.48
4.98
4.81
4.77
4.40
4.25
4.23
3.94
3.81
3.79
3.57
3.46
3.44
3.26
3.16
3.15

5.28
5.08
5.04
4.61
4.44
4.41
4.08
3.95
3.93
3.67
3.55
3.53
3.33
3.23
3.22
3.05
2.96
2.95

4.90
4.71
4.68
4.30
4.15
4.12
3.83
3.70
3.68
3.45
3.35
3.33
3.14
3.05
3.04
2.89
2.80
2.79

4.72
4.57
4.53
4.16
4.03
4.00
3.72
3.61
3.59
3.37
3.27
3.25
3.07
2.98
2.97
2.83
2.74
2.74

4.44
4.33
4.28
3.94
3.83
3.80
3.54
3.44
3.42
3.21
3.12
3.11
2.94
2.85
2.85
2.71
2.63
2.63

4.16
4.05
4.01
3.71
3.61
3.59
3.35
3.26
3.24
3.05
2.96
2.96
2.80
2.72
2.72
2.59
2.51
2.52

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

10.7
12.6
13.1
15.6
17.7
18.1
20.4
22.6
23.0
25.3
27.5
28.0
30.2
32.4
32.9
35.1
37.4
37.9

34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4
34.4

10.9
12.8
13.2
15.8
17.8
18.2
20.7
22.7
23.1
25.6
27.6
28.1
30.5
32.6
33.0
35.4
37.5
38.0

32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6

11.2
12.9
13.3
16.1
17.9
18.3
20.9
22.8
23.2
25.8
27.8
28.2
30.7
32.7
33.1
35.6
37.6
38.1

31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9
31.9

11.2
12.9
13.3
16.2
17.9
18.3
21.0
22.9
23.3
25.9
27.8
28.2
30.8
32.7
33.2
35.7
37.7
38.1

30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4
30.4

11.4
13.0
13.4
16.3
18.0
18.4
21.2
23.0
23.4
26.1
27.9
28.3
31.0
32.8
33.3
35.9
37.8
38.2

29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0
29.0

11.6
13.1
13.5
16.5
18.1
18.5
21.4
23.1
23.4
26.3
28.0
28.4
31.2
32.9
33.4
36.1
37.9
38.3

Combi. : Combination
Temp. : Temperature

40

ARWN300LA2
Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

130
30

35

40

15

20

25

120
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

115.6
119.4
119.9
120.0
123.9
124.5
130.7
130.7
130.7
130.7
130.7
130.7
130.7
130.7
130.7
130.7
130.7
130.7
109.8
112.5
113.1
113.0
116.1
116.7
122.9
123.3
123.6
123.6
123.6
123.6
123.6
123.6
123.6
123.6
123.6
123.6

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

18.8
18.9
18.9
17.2
17.5
17.4
17.9
17.5
17.3
17.2
16.7
16.5
16.6
16.0
15.8
16.1
15.3
15.2
18.9
18.8
18.8
16.7
16.9
16.9
17.0
16.8
16.6
16.2
15.8
15.6
15.4
14.9
14.7
14.8
14.1
13.9

19.4
19.4
19.6
17.5
17.9
17.9
17.9
17.6
17.3
17.2
16.8
16.6
16.6
16.1
15.9
16.0
15.4
15.2
19.5
19.4
19.5
17.2
17.4
17.4
16.9
16.6
16.4
15.9
15.5
15.3
15.0
14.5
14.4
14.4
13.8
13.7

20.2
20.2
20.3
18.0
18.4
18.5
18.0
17.7
17.4
17.3
16.9
16.7
16.7
16.2
16.0
16.1
15.5
15.3
20.2
20.2
20.2
17.7
17.9
18.0
16.8
16.5
16.3
15.6
15.3
15.1
14.7
14.3
14.1
14.0
13.4
13.3

19.9
19.3
19.4
17.9
18.2
18.3
17.6
17.3
17.1
16.8
16.5
16.3
16.1
15.6
15.4
15.5
14.9
14.7
19.8
19.3
19.3
17.5
17.6
17.6
16.4
16.1
15.9
15.2
14.9
14.7
14.2
13.8
13.6
13.5
12.9
12.8

19.0
18.4
18.5
17.9
18.2
18.3
17.3
17.0
16.8
16.4
16.1
15.8
15.5
15.1
14.9
14.9
14.3
14.1
18.9
18.4
18.4
17.2
17.3
17.2
15.9
15.6
15.4
14.7
14.4
14.2
13.7
13.2
13.1
12.9
12.4
12.3

17.3
16.8
18.5
17.6
18.0
18.0
16.3
16.0
15.8
15.3
15.0
14.8
14.2
13.8
13.6
13.5
13.0
12.8
17.2
16.8
17.9
16.7
16.7
16.7
14.9
14.6
14.5
13.7
13.4
13.2
12.5
12.2
12.0
11.7
11.3
11.2

TC:Total Capacity(kW)
PI :Power Input(kW)

41

5.92
9.85
10.9
10.3
14.7
15.7
14.1
19.2
20.3
18.7
24.0
25.2
23.5
28.8
30.0
28.2
33.7
34.9
6.38
10.1
11.1
10.8
15.0
15.9
14.8
19.5
20.6
19.4
24.3
25.4
24.1
29.1
30.3
28.9
34.0
35.2

115.3
118.9
119.9
119.7
123.5
124.5
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
127.6
109.6
112.1
113.0
112.7
115.4
116.3
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5

5.95
9.87
10.9
10.4
14.7
15.7
14.4
19.3
20.4
19.0
24.1
25.3
23.8
29.0
30.2
28.5
33.8
35.1
6.40
10.2
11.1
10.9
15.1
16.0
15.0
19.7
20.7
19.7
24.5
25.6
24.5
29.3
30.5
29.2
34.2
35.4

114.9
118.5
119.9
119.3
123.0
124.5
124.5
124.5
124.5
124.5
124.5
124.5
124.5
124.5
124.5
124.5
124.5
124.5
109.2
111.6
112.5
112.1
114.6
115.6
115.6
115.6
115.6
115.6
115.6
115.6
115.6
115.6
115.6
115.6
115.6
115.6

5.98
9.89
10.9
10.4
14.7
15.7
14.6
19.5
20.5
19.3
24.3
25.4
24.0
29.1
30.3
28.8
34.0
35.2
6.42
10.2
11.1
11.0
15.1
16.0
15.4
19.9
20.8
20.0
24.7
25.7
24.8
29.5
30.6
29.6
34.4
35.5

112.0
115.4
116.8
116.0
119.8
121.0
122.0
122.0
122.0
122.0
122.0
122.0
122.0
122.0
122.0
122.0
122.0
122.0
106.5
108.8
109.7
109.2
111.8
112.5
113.2
113.2
113.2
113.2
113.2
113.2
113.2
113.2
113.2
113.2
113.2
113.2

6.21
10.0
11.0
10.7
14.9
15.8
14.8
19.6
20.6
19.5
24.4
25.5
24.3
29.2
30.4
29.0
34.1
35.3
6.64
10.3
11.2
11.2
15.2
16.1
15.6
20.0
20.9
20.2
24.8
25.8
25.0
29.6
30.7
29.8
34.5
35.6

109.0
112.3
113.7
112.9
116.6
117.6
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
119.5
103.1
105.3
106.2
105.7
108.2
108.9
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1

6.44
10.2
11.1
10.9
15.0
15.9
15.0
19.7
20.7
19.7
24.5
25.6
24.5
29.3
30.5
29.2
34.2
35.4
6.91
10.5
11.3
11.5
15.4
16.2
15.8
20.1
21.0
20.5
24.9
25.9
25.3
29.8
30.8
30.1
34.7
35.7

102.9
106.1
107.3
106.2
110.1
111.0
112.5
112.5
112.5
112.5
112.5
112.5
112.5
112.5
112.5
112.5
112.5
112.5
97.6
99.7
100.6
99.8
102.4
103.0
104.0
104.0
104.0
104.0
104.0
104.0
104.0
104.0
104.0
104.0
104.0
104.0

6.92
10.4
11.3
11.5
15.3
16.1
15.6
20.0
21.0
20.3
24.8
25.8
25.1
29.7
30.7
29.9
34.6
35.6
7.34
10.7
11.5
12.0
15.6
16.4
16.3
20.4
21.3
21.0
25.2
26.1
25.8
30.1
31.1
30.6
35.0
36.0

Combi. : Combination
Temp. : Temperature

Outdoor Units

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Combi. Water Flow
(%) Temp. Rate TC
(C) (L/min) (kW)

15

20

25

110
30

35

40

15

20

25

100
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

103.9
105.6
106.3
106.0
108.3
109.0
115.0
115.9
116.4
116.4
116.4
116.4
116.4
116.4
116.4
116.4
116.4
116.4
98.1
98.8
99.5
99.0
100.5
101.2
107.1
108.6
109.3
109.3
109.3
109.3
109.3
109.3
109.3
109.3
109.3
109.3

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

19.0
18.8
18.7
16.3
16.4
16.3
16.2
16.0
15.9
15.2
14.8
14.6
14.2
13.7
13.6
13.5
12.8
12.7
19.1
18.7
18.7
15.8
15.8
15.8
15.3
15.2
15.1
14.1
13.8
13.7
13.0
12.6
12.5
12.2
11.6
11.4

19.5
19.4
19.4
16.9
16.9
16.9
15.9
15.7
15.5
14.6
14.2
14.0
13.5
13.0
12.9
12.8
12.2
12.1
19.6
19.4
19.3
16.5
16.4
16.3
15.0
14.7
14.5
13.2
12.9
12.8
11.9
11.5
11.4
11.2
10.7
10.6

20.3
20.1
20.0
17.5
17.5
17.4
15.6
15.4
15.1
14.0
13.7
13.5
12.8
12.4
12.3
11.9
11.4
11.3
20.3
20.1
19.9
17.3
17.1
16.9
14.4
14.2
14.0
12.4
12.1
12.0
10.9
10.6
10.5
9.76
9.38
9.28

19.7
19.3
19.2
17.1
17.0
16.9
15.1
14.9
14.7
13.6
13.3
13.1
12.4
12.0
11.9
11.4
11.0
10.9
19.6
19.4
19.2
16.7
16.5
16.2
13.9
13.7
13.5
12.0
11.7
11.6
10.5
10.2
10.1
9.44
9.08
9.00

18.8
18.3
18.2
16.5
16.4
16.2
14.5
14.2
14.1
13.0
12.7
12.6
11.8
11.4
11.3
10.9
10.5
10.4
18.6
18.2
18.0
15.8
15.4
15.2
13.1
12.9
12.7
11.3
11.0
10.9
9.93
9.63
9.57
8.90
8.56
8.51

17.2
16.8
17.2
15.7
15.5
15.4
13.5
13.3
13.1
12.1
11.8
11.7
10.9
10.6
10.5
10.0
9.62
9.56
17.2
16.7
16.6
14.8
14.2
14.1
12.1
11.9
11.8
10.4
10.2
10.1
9.21
8.94
8.89
8.27
7.96
7.93

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

6.84
10.4
11.3
11.3
15.3
16.2
15.4
19.9
20.8
20.0
24.7
25.7
24.7
29.5
30.6
29.5
34.4
35.5
7.30
10.7
11.6
11.8
15.6
16.4
16.1
20.2
21.1
20.6
25.0
25.9
25.4
29.8
30.9
30.2
34.7
35.8

103.8
105.2
106.0
105.7
107.2
108.1
111.3
111.3
111.3
111.3
111.3
111.3
111.3
111.3
111.3
111.3
111.3
111.3
98.1
98.4
99.1
98.8
99.1
99.8
103.2
103.2
103.2
103.2
103.2
103.2
103.2
103.2
103.2
103.2
103.2
103.2

6.85
10.5
11.3
11.5
15.4
16.2
15.7
20.1
21.0
20.4
24.9
25.9
25.2
29.7
30.8
30.0
34.6
35.7
7.30
10.8
11.6
12.1
15.7
16.5
16.4
20.4
21.3
21.1
25.3
26.2
25.9
30.1
31.1
30.7
35.0
36.0

103.5
104.7
105.2
105.0
106.2
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
106.7
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8
97.8

6.87
10.5
11.4
11.6
15.4
16.3
16.1
20.3
21.2
20.8
25.1
26.0
25.6
29.9
31.0
30.4
34.8
35.9
7.32
10.8
11.6
12.1
15.8
16.6
16.9
20.7
21.5
21.6
25.5
26.4
26.4
30.4
31.3
31.2
35.3
36.2

101.1
102.2
102.7
102.4
103.7
104.1
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6
95.6

7.06
10.6
11.5
11.8
15.6
16.4
16.3
20.4
21.3
21.0
25.2
26.1
25.8
30.1
31.0
30.6
34.9
36.0
7.49
10.9
11.7
12.3
15.9
16.7
17.0
20.8
21.6
21.8
25.6
26.5
26.6
30.5
31.4
31.4
35.4
36.3

97.2
98.3
98.8
98.5
99.7
100.1
100.7
100.7
100.7
100.7
100.7
100.7
100.7
100.7
100.7
100.7
100.7
100.7
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3

7.37
10.8
11.6
12.1
15.7
16.5
16.6
20.5
21.4
21.3
25.4
26.3
26.1
30.2
31.2
30.9
35.1
36.1
7.83
11.1
11.8
12.7
16.1
16.8
17.4
20.9
21.7
22.1
25.8
26.6
27.0
30.7
31.5
31.8
35.6
36.5

92.3
93.3
93.8
93.4
94.7
95.0
95.5
95.5
95.5
95.5
95.5
95.5
95.5
95.5
95.5
95.5
95.5
95.5
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0

7.75
11.0
11.8
12.5
15.9
16.7
17.0
20.8
21.6
21.8
25.6
26.5
26.6
30.5
31.4
31.4
35.4
36.3
8.17
11.2
12.0
13.0
16.3
17.0
17.8
21.1
21.9
22.5
26.0
26.8
27.3
30.9
31.7
32.2
35.8
36.6

Combi. : Combination
Temp. : Temperature

42

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

90
30

35

40

15

20

25

80
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

92.8
93.1
93.5
93.2
94.0
94.3
97.3
98.0
98.4
98.4
98.4
98.4
98.4
98.4
98.4
98.4
98.4
98.4
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

17.4
17.0
16.9
14.5
14.4
14.3
13.5
13.4
13.3
12.4
12.1
12.0
11.4
11.0
10.9
10.6
10.1
10.0
15.8
15.3
15.2
13.3
13.0
12.9
11.8
11.5
11.4
10.7
10.4
10.3
9.73
9.44
9.37
9.02
8.65
8.59

17.3
17.0
16.9
14.7
14.5
14.4
13.1
12.8
12.7
11.6
11.3
11.2
10.4
10.1
10.0
9.77
9.36
9.27
15.0
14.6
14.5
12.8
12.5
12.4
11.2
10.9
10.8
9.97
9.71
9.62
9.00
8.73
8.66
8.36
8.05
7.98

17.4
17.1
16.9
14.8
14.6
14.4
12.5
12.3
12.2
10.9
10.6
10.5
9.63
9.34
9.24
8.66
8.34
8.26
14.4
14.1
13.9
12.4
12.1
12.0
10.7
10.4
10.3
9.36
9.12
9.03
8.36
8.11
8.04
7.56
7.30
7.24

16.7
16.5
16.3
14.4
14.1
13.9
12.1
11.9
11.8
10.5
10.3
10.2
9.33
9.05
8.97
8.40
8.09
8.03
13.9
13.6
13.4
12.0
11.7
11.6
10.3
10.1
10.0
9.08
8.85
8.77
8.12
7.88
7.82
7.35
7.10
7.05

15.9
15.5
15.3
13.6
13.3
13.1
11.4
11.2
11.1
9.93
9.70
9.63
8.81
8.55
8.50
7.94
7.65
7.61
13.1
12.8
12.7
11.4
11.1
11.0
9.75
9.54
9.47
8.59
8.38
8.33
7.70
7.47
7.43
6.98
6.74
6.71

14.7
14.3
14.2
12.7
12.3
12.1
10.6
10.4
10.3
9.24
9.02
8.97
8.22
7.97
7.94
7.42
7.15
7.12
12.2
11.9
11.7
10.7
10.3
10.2
9.11
8.91
8.85
8.05
7.84
7.81
7.22
7.01
6.98
6.56
6.34
6.32

TC:Total Capacity(kW)
PI :Power Input(kW)

43

7.72
11.0
11.8
12.4
15.9
16.7
16.9
20.7
21.5
21.5
25.5
26.3
26.3
30.3
31.3
31.1
35.2
36.2
8.13
11.2
12.0
13.0
16.2
17.0
17.7
21.1
21.9
22.5
26.0
26.8
27.3
30.9
31.7
32.1
35.8
36.6

90.3
90.5
90.8
90.7
90.8
91.2
92.9
92.9
92.9
92.9
92.9
92.9
92.9
92.9
92.9
92.9
92.9
92.9
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5

7.91
11.1
11.9
12.7
16.1
16.8
17.3
20.9
21.7
22.0
25.7
26.6
26.8
30.6
31.5
31.6
35.5
36.4
8.52
11.4
12.2
13.4
16.5
17.1
18.1
21.3
22.0
22.9
26.2
26.9
27.7
31.1
31.9
32.6
36.0
36.8

88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
88.0
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2

8.09
11.2
12.0
12.9
16.2
16.9
17.7
21.1
21.8
22.4
26.0
26.7
27.2
30.8
31.7
32.1
35.7
36.6
8.86
11.6
12.3
13.7
16.6
17.3
18.5
21.5
22.2
23.3
26.4
27.1
28.1
31.3
32.0
33.0
36.2
37.0

86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
86.1
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5

8.24
11.3
12.0
13.1
16.3
17.0
17.8
21.2
21.9
22.6
26.1
26.8
27.4
30.9
31.7
32.3
35.8
36.7
8.99
11.7
12.4
13.8
16.7
17.3
18.6
21.6
22.3
23.4
26.5
27.2
28.3
31.4
32.1
33.1
36.3
37.0

82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
82.2
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1

8.55
11.5
12.2
13.4
16.5
17.1
18.2
21.4
22.0
22.9
26.2
27.0
27.8
31.1
31.9
32.6
36.0
36.8
9.26
11.8
12.5
14.1
16.9
17.5
18.9
21.8
22.4
23.7
26.6
27.3
28.6
31.5
32.2
33.4
36.5
37.2

78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
78.3
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6

8.85
11.6
12.3
13.7
16.6
17.3
18.5
21.5
22.2
23.3
26.4
27.1
28.1
31.3
32.0
33.0
36.2
37.0
9.54
12.0
12.6
14.4
17.0
17.6
19.2
21.9
22.5
24.0
26.8
27.4
28.9
31.7
32.4
33.7
36.6
37.3

Combi. : Combination
Temp. : Temperature

Outdoor Units

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Combi. Water Flow
(%) Temp. Rate TC
(C) (L/min) (kW)

15

20

25

70
30

35

40

15

20

25

60
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6
65.6

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

13.5
13.1
13.0
11.5
11.2
11.1
10.2
9.91
9.82
9.16
8.91
8.84
8.34
8.09
8.03
7.71
7.41
7.36
11.2
10.9
10.8
9.61
9.33
9.26
8.51
8.27
8.21
7.65
7.43
7.38
6.95
6.74
6.70
6.39
6.17
6.14

12.7
12.4
12.3
10.9
10.7
10.6
9.59
9.35
9.26
8.56
8.32
8.26
7.74
7.50
7.45
7.16
6.91
6.86
10.5
10.2
10.1
9.06
8.80
8.73
7.99
7.76
7.70
7.15
6.94
6.89
6.47
6.28
6.24
5.97
5.77
5.73

12.1
11.8
11.7
10.5
10.3
10.1
9.11
8.87
8.79
8.04
7.82
7.75
7.21
6.99
6.94
6.54
6.33
6.28
9.90
9.60
9.51
8.61
8.37
8.29
7.55
7.33
7.27
6.72
6.53
6.48
6.06
5.88
5.84
5.53
5.35
5.32

11.7
11.4
11.3
10.2
9.92
9.83
8.82
8.61
8.53
7.81
7.60
7.54
7.02
6.81
6.76
6.38
6.16
6.13
9.54
9.28
9.20
8.34
8.11
8.04
7.32
7.12
7.07
6.54
6.35
6.31
5.91
5.73
5.70
5.40
5.23
5.20

11.1
10.8
10.7
9.62
9.38
9.29
8.34
8.15
8.09
7.40
7.21
7.17
6.66
6.46
6.44
6.07
5.86
5.84
9.00
8.77
8.68
7.89
7.68
7.62
6.94
6.76
6.72
6.21
6.04
6.01
5.63
5.46
5.44
5.15
4.98
4.97

10.3
10.0
9.92
9.04
8.75
8.68
7.82
7.64
7.59
6.96
6.77
6.75
6.28
6.09
6.07
5.73
5.53
5.52
8.40
8.18
8.10
7.42
7.20
7.14
6.53
6.36
6.33
5.86
5.70
5.68
5.33
5.17
5.16
4.89
4.73
4.73

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

8.99
11.7
12.4
13.8
16.7
17.3
18.6
21.6
22.3
23.4
26.5
27.2
28.3
31.4
32.1
33.1
36.3
37.0
9.85
12.2
12.7
14.7
17.2
17.7
19.5
22.1
22.6
24.3
27.0
27.6
29.2
31.9
32.5
34.1
36.8
37.5

72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
72.2
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9
61.9

9.33
11.9
12.5
14.2
16.9
17.5
19.0
21.8
22.4
23.8
26.7
27.3
28.6
31.6
32.3
33.5
36.5
37.2
10.1
12.3
12.9
15.0
17.3
17.9
19.8
22.3
22.8
24.7
27.2
27.7
29.5
32.1
32.7
34.4
37.0
37.6

68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
68.5
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7
58.7

9.62
12.0
12.6
14.5
17.1
17.6
19.3
22.0
22.5
24.1
26.9
27.5
29.0
31.8
32.4
33.8
36.7
37.4
10.4
12.5
13.0
15.3
17.5
18.0
20.1
22.4
22.9
24.9
27.3
27.8
29.8
32.2
32.8
34.7
37.2
37.7

66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
66.9
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4
57.4

9.74
12.1
12.7
14.6
17.1
17.7
19.4
22.0
22.6
24.2
26.9
27.5
29.1
31.8
32.5
34.0
36.8
37.4
10.5
12.5
13.0
15.4
17.5
18.0
20.2
22.5
22.9
25.1
27.4
27.9
29.9
32.3
32.8
34.8
37.2
37.8

63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
63.9
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8
54.8

9.98
12.2
12.8
14.9
17.3
17.8
19.7
22.2
22.7
24.5
27.1
27.6
29.4
32.0
32.6
34.2
36.9
37.5
10.7
12.6
13.1
15.6
17.7
18.1
20.4
22.6
23.0
25.3
27.5
28.0
30.2
32.4
32.9
35.1
37.3
37.9

60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2
52.2

10.2
12.4
12.9
15.1
17.4
17.9
19.9
22.3
22.8
24.8
27.2
27.7
29.6
32.1
32.7
34.5
37.1
37.6
10.9
12.7
13.2
15.8
17.8
18.2
20.7
22.7
23.1
25.5
27.6
28.1
30.4
32.5
33.0
35.3
37.5
38.0

Combi. : Combination
Temp. : Temperature

44

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

50
30

35

40

100
192
240
100
192
240
100
192
240
100
192
240
100
192
240
100
192
240

54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7
54.7

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

8.96
8.62
8.55
7.77
7.50
7.45
6.86
6.64
6.59
6.14
5.95
5.92
5.56
5.39
5.37
5.08
4.93
4.91

8.25
7.94
7.88
7.20
6.95
6.90
6.38
6.17
6.14
5.74
5.56
5.53
5.21
5.05
5.03
4.77
4.63
4.61

7.66
7.37
7.31
6.72
6.48
6.44
5.99
5.79
5.75
5.40
5.23
5.20
4.92
4.77
4.74
4.51
4.38
4.36

7.37
7.14
7.08
6.51
6.30
6.26
5.82
5.64
5.61
5.26
5.10
5.08
4.81
4.66
4.64
4.42
4.29
4.28

6.94
6.76
6.70
6.16
5.99
5.95
5.53
5.37
5.35
5.02
4.87
4.86
4.60
4.46
4.45
4.24
4.11
4.11

6.50
6.33
6.27
5.80
5.64
5.60
5.24
5.09
5.07
4.77
4.63
4.62
4.38
4.25
4.25
4.05
3.93
3.93

TC:Total Capacity(kW)
PI :Power Input(kW)

45

10.7
12.6
13.1
15.6
17.7
18.1
20.4
22.6
23.0
25.3
27.5
28.0
30.2
32.4
32.9
35.1
37.4
37.9

51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6
51.6

10.9
12.8
13.2
15.8
17.8
18.2
20.7
22.7
23.1
25.6
27.6
28.1
30.5
32.6
33.0
35.4
37.5
38.0

48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9
48.9

11.2
12.9
13.3
16.1
17.9
18.3
20.9
22.8
23.2
25.8
27.8
28.2
30.7
32.7
33.1
35.6
37.6
38.1

47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8
47.8

11.2
12.9
13.3
16.2
17.9
18.3
21.0
22.9
23.3
25.9
27.8
28.2
30.8
32.7
33.2
35.7
37.7
38.1

45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7
45.7

11.4
13.0
13.4
16.3
18.0
18.4
21.2
23.0
23.4
26.1
27.9
28.3
31.0
32.8
33.3
35.9
37.8
38.2

43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5

11.6
13.1
13.5
16.5
18.1
18.5
21.4
23.1
23.4
26.3
28.0
28.4
31.2
32.9
33.4
36.1
37.9
38.3

Combi. : Combination
Temp. : Temperature

Outdoor Units

ARWN400LA2
Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

130
30

35

40

15

20

25

120
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

154.1
159.1
159.9
160.0
165.2
166.0
174.3
174.3
174.3
174.3
174.3
174.3
174.3
174.3
174.3
174.3
174.3
174.3
146.4
150.0
150.8
150.7
154.8
155.6
163.8
164.4
164.8
164.8
164.8
164.8
164.8
164.8
164.8
164.8
164.8
164.8

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

24.1
24.2
24.3
22.0
22.4
22.4
23.0
22.5
22.2
22.1
21.5
21.2
21.3
20.5
20.3
20.6
19.7
19.4
24.2
24.1
24.2
21.4
21.7
21.7
21.9
21.5
21.2
20.8
20.2
20.0
19.7
19.1
18.8
18.9
18.1
17.9

24.8
24.8
25.1
22.5
22.9
22.9
22.9
22.5
22.2
22.0
21.5
21.2
21.2
20.5
20.3
20.5
19.7
19.5
24.9
24.8
25.0
22.0
22.2
22.3
21.7
21.3
21.0
20.3
19.8
19.6
19.2
18.6
18.4
18.5
17.7
17.5

25.8
25.8
25.9
23.0
23.5
23.7
23.0
22.6
22.3
22.1
21.6
21.3
21.3
20.7
20.4
20.6
19.8
19.6
25.9
25.8
25.8
22.7
23.0
23.0
21.5
21.1
20.9
20.0
19.6
19.3
18.9
18.3
18.1
17.9
17.2
17.0

25.5
24.7
24.8
22.9
23.3
23.4
22.5
22.2
21.9
21.5
21.1
20.8
20.6
20.0
19.7
19.8
19.0
18.8
25.4
24.7
24.7
22.4
22.6
22.5
21.0
20.6
20.4
19.5
19.0
18.8
18.2
17.7
17.5
17.2
16.6
16.4

24.4
23.6
23.7
22.9
23.3
23.4
22.1
21.8
21.5
21.0
20.5
20.3
19.9
19.3
19.0
19.0
18.3
18.1
24.2
23.5
23.5
22.0
22.1
22.1
20.3
20.0
19.7
18.8
18.4
18.2
17.5
17.0
16.8
16.5
15.8
15.7

22.1
21.5
23.7
22.5
23.0
23.0
20.8
20.5
20.2
19.6
19.2
18.9
18.2
17.6
17.4
17.2
16.6
16.4
22.1
21.4
22.9
21.3
21.4
21.3
19.0
18.7
18.5
17.5
17.1
16.9
16.0
15.6
15.4
15.0
14.4
14.3

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

5.92
9.85
10.9
10.3
14.7
15.7
14.1
19.2
20.3
18.7
24.0
25.2
23.5
28.8
30.0
28.2
33.7
34.9
6.38
10.1
11.1
10.8
15.0
15.9
14.8
19.5
20.6
19.4
24.3
25.4
24.1
29.1
30.3
28.9
34.0
35.2

153.7
158.6
159.9
159.6
164.6
166.0
170.1
170.1
170.1
170.1
170.1
170.1
170.1
170.1
170.1
170.1
170.1
170.1
146.1
149.4
150.6
150.3
153.8
155.0
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3

5.95
9.87
10.9
10.4
14.7
15.7
14.4
19.3
20.4
19.0
24.1
25.3
23.8
29.0
30.2
28.5
33.8
35.1
6.40
10.2
11.1
10.9
15.1
16.0
15.0
19.7
20.7
19.7
24.5
25.6
24.5
29.3
30.5
29.2
34.2
35.4

153.3
158.0
159.9
159.1
164.0
166.0
166.0
166.0
166.0
166.0
166.0
166.0
166.0
166.0
166.0
166.0
166.0
166.0
145.6
148.8
150.1
149.5
152.8
154.1
154.1
154.1
154.1
154.1
154.1
154.1
154.1
154.1
154.1
154.1
154.1
154.1

5.98
9.89
10.9
10.4
14.7
15.7
14.6
19.5
20.5
19.3
24.3
25.4
24.0
29.1
30.3
28.8
34.0
35.2
6.42
10.2
11.1
11.0
15.1
16.0
15.4
19.9
20.8
20.0
24.7
25.7
24.8
29.5
30.6
29.6
34.4
35.5

149.3
153.9
155.7
154.6
159.8
161.3
162.7
162.7
162.7
162.7
162.7
162.7
162.7
162.7
162.7
162.7
162.7
162.7
142.0
145.1
146.3
145.6
149.0
150.1
150.9
150.9
150.9
150.9
150.9
150.9
150.9
150.9
150.9
150.9
150.9
150.9

6.21
10.0
11.0
10.7
14.9
15.8
14.8
19.6
20.6
19.5
24.4
25.5
24.3
29.2
30.4
29.0
34.1
35.3
6.64
10.3
11.2
11.2
15.2
16.1
15.6
20.0
20.9
20.2
24.8
25.8
25.0
29.6
30.7
29.8
34.5
35.6

145.3
149.8
151.6
150.5
155.5
156.9
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
159.3
137.4
140.4
141.6
140.9
144.2
145.2
146.8
146.8
146.8
146.8
146.8
146.8
146.8
146.8
146.8
146.8
146.8
146.8

6.44
10.2
11.1
10.9
15.0
15.9
15.0
19.7
20.7
19.7
24.5
25.6
24.5
29.3
30.5
29.2
34.2
35.4
6.91
10.5
11.3
11.5
15.4
16.2
15.8
20.1
21.0
20.5
24.9
25.9
25.3
29.8
30.8
30.1
34.7
35.7

137.2
141.4
143.1
141.6
146.8
148.0
150.1
150.1
150.1
150.1
150.1
150.1
150.1
150.1
150.1
150.1
150.1
150.1
130.1
132.9
134.1
133.1
136.5
137.3
138.7
138.7
138.7
138.7
138.7
138.7
138.7
138.7
138.7
138.7
138.7
138.7

6.92
10.4
11.3
11.5
15.3
16.1
15.6
20.0
21.0
20.3
24.8
25.8
25.1
29.7
30.7
29.9
34.6
35.6
7.34
10.7
11.5
12.0
15.6
16.4
16.3
20.4
21.3
21.0
25.2
26.1
25.8
30.1
31.1
30.6
35.0
36.0

Combi. : Combination
Temp. : Temperature

46

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Combi. Water Flow
(%) Temp. Rate TC
(C) (L/min) (kW)

15

20

25

110
30

35

40

15

20

25

100
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

138.6
140.8
141.7
141.3
144.4
145.3
153.3
154.6
155.3
155.3
155.3
155.3
155.3
155.3
155.3
155.3
155.3
155.3
130.8
131.7
132.6
132.0
134.0
134.9
142.9
144.7
145.8
145.8
145.8
145.8
145.8
145.8
145.8
145.8
145.8
145.8

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

24.3
24.1
24.0
20.8
21.0
20.9
20.7
20.5
20.3
19.4
19.0
18.7
18.2
17.6
17.4
17.3
16.4
16.3
24.4
24.0
23.9
20.2
20.3
20.2
19.6
19.5
19.4
18.1
17.7
17.5
16.6
16.1
16.0
15.6
14.8
14.7

25.0
24.8
24.9
21.6
21.6
21.6
20.4
20.1
19.8
18.6
18.2
18.0
17.2
16.7
16.5
16.4
15.7
15.5
25.0
24.8
24.7
21.1
21.0
20.9
19.1
18.8
18.6
16.9
16.5
16.4
15.2
14.8
14.6
14.3
13.7
13.5

26.0
25.8
25.7
22.4
22.4
22.3
20.0
19.7
19.4
17.9
17.5
17.3
16.4
15.9
15.7
15.2
14.6
14.4
26.0
25.8
25.5
22.1
21.9
21.6
18.5
18.2
17.9
15.9
15.5
15.3
14.0
13.5
13.4
12.5
12.0
11.9

25.2
24.8
24.6
21.9
21.8
21.7
19.4
19.1
18.8
17.4
17.0
16.8
15.9
15.4
15.2
14.6
14.1
14.0
25.1
24.8
24.5
21.4
21.1
20.8
17.8
17.5
17.3
15.3
15.0
14.8
13.5
13.1
13.0
12.1
11.6
11.5

24.0
23.4
23.3
21.1
20.9
20.8
18.5
18.2
18.0
16.6
16.2
16.1
15.1
14.6
14.5
13.9
13.4
13.3
23.8
23.2
23.0
20.2
19.8
19.5
16.7
16.5
16.3
14.4
14.1
14.0
12.7
12.3
12.2
11.4
11.0
10.9

22.0
21.4
22.0
20.1
19.8
19.7
17.3
17.0
16.8
15.4
15.1
15.0
13.9
13.5
13.4
12.8
12.3
12.2
22.0
21.4
21.2
18.9
18.2
18.0
15.5
15.2
15.1
13.3
13.1
13.0
11.8
11.4
11.4
10.6
10.2
10.1

TC:Total Capacity(kW)
PI :Power Input(kW)

47

6.84
10.4
11.3
11.3
15.3
16.2
15.4
19.9
20.8
20.0
24.7
25.7
24.7
29.5
30.6
29.5
34.4
35.5
7.30
10.7
11.6
11.8
15.6
16.4
16.1
20.2
21.1
20.6
25.0
25.9
25.4
29.8
30.9
30.2
34.7
35.8

138.4
140.3
141.4
141.0
143.0
144.1
148.4
148.4
148.4
148.4
148.4
148.4
148.4
148.4
148.4
148.4
148.4
148.4
130.8
131.2
132.1
131.7
132.2
133.1
137.6
137.6
137.6
137.6
137.6
137.6
137.6
137.6
137.6
137.6
137.6
137.6

6.85
10.5
11.3
11.5
15.4
16.2
15.7
20.1
21.0
20.4
24.9
25.9
25.2
29.7
30.8
30.0
34.6
35.7
7.30
10.8
11.6
12.1
15.7
16.5
16.4
20.4
21.3
21.1
25.3
26.2
25.9
30.1
31.1
30.7
35.0
36.0

138.0
139.6
140.2
140.0
141.6
142.3
142.3
142.3
142.3
142.3
142.3
142.3
142.3
142.3
142.3
142.3
142.3
142.3
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4
130.4

6.87
10.5
11.4
11.6
15.4
16.3
16.1
20.3
21.2
20.8
25.1
26.0
25.6
29.9
31.0
30.4
34.8
35.9
7.32
10.8
11.6
12.1
15.8
16.6
16.9
20.7
21.5
21.6
25.5
26.4
26.4
30.4
31.3
31.2
35.3
36.2

134.8
136.3
136.9
136.6
138.3
138.8
139.2
139.2
139.2
139.2
139.2
139.2
139.2
139.2
139.2
139.2
139.2
139.2
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5
127.5

7.06
10.6
11.5
11.8
15.6
16.4
16.3
20.4
21.3
21.0
25.2
26.1
25.8
30.1
31.0
30.6
34.9
36.0
7.49
10.9
11.7
12.3
15.9
16.7
17.0
20.8
21.6
21.8
25.6
26.5
26.6
30.5
31.4
31.4
35.4
36.3

129.6
131.1
131.7
131.3
133.0
133.5
134.3
134.3
134.3
134.3
134.3
134.3
134.3
134.3
134.3
134.3
134.3
134.3
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8
121.8

7.37
10.8
11.6
12.1
15.7
16.5
16.6
20.5
21.4
21.3
25.4
26.3
26.1
30.2
31.2
30.9
35.1
36.1
7.83
11.1
11.8
12.7
16.1
16.8
17.4
20.9
21.7
22.1
25.8
26.6
27.0
30.7
31.5
31.8
35.6
36.5

123.0
124.5
125.0
124.5
126.3
126.7
127.3
127.3
127.3
127.3
127.3
127.3
127.3
127.3
127.3
127.3
127.3
127.3
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0
116.0

7.75
11.0
11.8
12.5
15.9
16.7
17.0
20.8
21.6
21.8
25.6
26.5
26.6
30.5
31.4
31.4
35.4
36.3
8.17
11.2
12.0
13.0
16.3
17.0
17.8
21.1
21.9
22.5
26.0
26.8
27.3
30.9
31.7
32.2
35.8
36.6

Combi. : Combination
Temp. : Temperature

Outdoor Units

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

90
30

35

40

15

20

25

80
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

123.7
124.2
124.6
124.3
125.3
125.8
129.7
130.7
131.2
131.2
131.2
131.2
131.2
131.2
131.2
131.2
131.2
131.2
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6
116.6

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

22.4
21.8
21.7
18.7
18.5
18.4
17.4
17.2
17.0
15.9
15.5
15.4
14.6
14.1
14.0
13.6
13.0
12.8
20.3
19.7
19.5
17.1
16.7
16.5
15.2
14.8
14.7
13.7
13.3
13.2
12.5
12.1
12.0
11.6
11.1
11.0

22.1
21.7
21.6
18.8
18.5
18.4
16.7
16.4
16.2
14.8
14.5
14.3
13.4
13.0
12.8
12.5
12.0
11.9
19.2
18.7
18.5
16.4
16.0
15.9
14.3
14.0
13.9
12.8
12.4
12.3
11.5
11.2
11.1
10.7
10.3
10.2

22.2
21.9
21.7
19.0
18.7
18.5
16.1
15.7
15.5
13.9
13.6
13.4
12.3
12.0
11.8
11.1
10.7
10.6
18.4
18.0
17.8
15.9
15.5
15.4
13.6
13.3
13.2
12.0
11.7
11.6
10.7
10.4
10.3
9.67
9.34
9.26

21.4
21.1
20.9
18.4
18.0
17.8
15.5
15.2
15.0
13.5
13.1
13.0
11.9
11.6
11.5
10.7
10.4
10.3
17.7
17.4
17.2
15.4
15.0
14.9
13.2
12.9
12.8
11.6
11.3
11.2
10.4
10.1
10.0
9.41
9.08
9.02

20.3
19.8
19.6
17.4
17.0
16.8
14.6
14.3
14.2
12.7
12.4
12.3
11.3
10.9
10.9
10.2
9.79
9.74
16.8
16.4
16.2
14.5
14.2
14.0
12.5
12.2
12.1
11.0
10.7
10.7
9.85
9.55
9.51
8.93
8.62
8.59

18.8
18.3
18.1
16.3
15.7
15.5
13.6
13.3
13.2
11.8
11.5
11.5
10.5
10.2
10.2
9.49
9.14
9.12
15.6
15.2
15.0
13.6
13.2
13.1
11.7
11.4
11.3
10.3
10.0
10.0
9.24
8.97
8.94
8.40
8.11
8.09

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

7.72
11.0
11.8
12.4
15.9
16.7
16.9
20.7
21.5
21.5
25.5
26.3
26.3
30.3
31.3
31.1
35.2
36.2
8.13
11.2
12.0
13.0
16.2
17.0
17.7
21.1
21.9
22.5
26.0
26.8
27.3
30.9
31.7
32.1
35.8
36.6

120.4
120.6
121.1
120.9
121.1
121.6
123.8
123.8
123.8
123.8
123.8
123.8
123.8
123.8
123.8
123.8
123.8
123.8
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1
110.1

7.91
11.1
11.9
12.7
16.1
16.8
17.3
20.9
21.7
22.0
25.7
26.6
26.8
30.6
31.5
31.6
35.5
36.4
8.52
11.4
12.2
13.4
16.5
17.1
18.1
21.3
22.0
22.9
26.2
26.9
27.7
31.1
31.9
32.6
36.0
36.8

117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
117.4
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3
104.3

8.09
11.2
12.0
12.9
16.2
16.9
17.7
21.1
21.8
22.4
26.0
26.7
27.2
30.8
31.7
32.1
35.7
36.6
8.86
11.6
12.3
13.7
16.6
17.3
18.5
21.5
22.2
23.3
26.4
27.1
28.1
31.3
32.0
33.0
36.2
37.0

114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
114.8
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0

8.24
11.3
12.0
13.1
16.3
17.0
17.8
21.2
21.9
22.6
26.1
26.8
27.4
30.9
31.7
32.3
35.8
36.7
8.99
11.7
12.4
13.8
16.7
17.3
18.6
21.6
22.3
23.4
26.5
27.2
28.3
31.4
32.1
33.1
36.3
37.0

109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
109.6
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4

8.55
11.5
12.2
13.4
16.5
17.1
18.2
21.4
22.0
22.9
26.2
27.0
27.8
31.1
31.9
32.6
36.0
36.8
9.26
11.8
12.5
14.1
16.9
17.5
18.9
21.8
22.4
23.7
26.6
27.3
28.6
31.5
32.2
33.4
36.5
37.2

104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
104.4
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8
92.8

8.85
11.6
12.3
13.7
16.6
17.3
18.5
21.5
22.2
23.3
26.4
27.1
28.1
31.3
32.0
33.0
36.2
37.0
9.54
12.0
12.6
14.4
17.0
17.6
19.2
21.9
22.5
24.0
26.8
27.4
28.9
31.7
32.4
33.7
36.6
37.3

Combi. : Combination
Temp. : Temperature

48

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Combi. Water Flow
(%) Temp. Rate TC
(C) (L/min) (kW)

15

20

25

70
30

35

40

15

20

25

60
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
102.0
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

17.3
16.8
16.6
14.7
14.3
14.2
13.0
12.7
12.6
11.7
11.4
11.3
10.7
10.4
10.3
9.88
9.50
9.44
14.4
13.9
13.8
12.3
12.0
11.9
10.9
10.6
10.5
9.81
9.53
9.46
8.91
8.64
8.59
8.20
7.91
7.87

16.3
15.9
15.7
14.0
13.6
13.5
12.3
12.0
11.9
11.0
10.7
10.6
9.90
9.60
9.53
9.17
8.84
8.78
13.4
13.0
12.9
11.6
11.3
11.2
10.2
9.93
9.85
9.14
8.88
8.82
8.28
8.03
7.98
7.63
7.38
7.34

15.5
15.1
15.0
13.4
13.1
13.0
11.7
11.4
11.2
10.3
10.0
9.92
9.23
8.95
8.88
8.37
8.10
8.04
12.7
12.3
12.2
11.0
10.7
10.6
9.66
9.38
9.30
8.60
8.35
8.29
7.76
7.53
7.47
7.07
6.85
6.81

15.0
14.6
14.5
13.0
12.7
12.6
11.3
11.0
10.9
10.0
9.72
9.65
8.98
8.71
8.65
8.16
7.89
7.84
12.2
11.9
11.8
10.7
10.4
10.3
9.37
9.11
9.05
8.36
8.13
8.08
7.56
7.34
7.30
6.91
6.69
6.66

14.1
13.8
13.7
12.3
12.0
11.9
10.7
10.4
10.4
9.47
9.22
9.17
8.53
8.27
8.24
7.76
7.50
7.47
11.5
11.2
11.1
10.1
9.83
9.75
8.88
8.65
8.60
7.95
7.73
7.69
7.20
6.99
6.97
6.59
6.38
6.36

13.2
12.8
12.7
11.6
11.2
11.1
10.0
9.77
9.71
8.90
8.67
8.63
8.03
7.79
7.77
7.33
7.08
7.07
10.7
10.5
10.4
9.50
9.21
9.14
8.35
8.14
8.10
7.50
7.30
7.27
6.82
6.62
6.60
6.26
6.05
6.05

TC:Total Capacity(kW)
PI :Power Input(kW)

49

8.99
11.7
12.4
13.8
16.7
17.3
18.6
21.6
22.3
23.4
26.5
27.2
28.3
31.4
32.1
33.1
36.3
37.0
9.85
12.2
12.7
14.7
17.2
17.7
19.5
22.1
22.6
24.3
27.0
27.6
29.2
31.9
32.5
34.1
36.8
37.5

96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
96.3
82.6
82.6
82.6
82.6
82.6
82.6
82.6
82.6
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5
82.5

9.33
11.9
12.5
14.2
16.9
17.5
19.0
21.8
22.4
23.8
26.7
27.3
28.6
31.6
32.3
33.5
36.5
37.2
10.1
12.3
12.9
15.0
17.3
17.9
19.8
22.3
22.8
24.7
27.2
27.7
29.5
32.1
32.7
34.4
37.0
37.6

91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
91.3
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2
78.2

9.62
12.0
12.6
14.5
17.1
17.6
19.3
22.0
22.5
24.1
26.9
27.5
29.0
31.8
32.4
33.8
36.7
37.4
10.4
12.5
13.0
15.3
17.5
18.0
20.1
22.4
22.9
24.9
27.3
27.8
29.8
32.2
32.8
34.7
37.2
37.7

89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
89.3
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5
76.5

9.74
12.1
12.7
14.6
17.1
17.7
19.4
22.0
22.6
24.2
26.9
27.5
29.1
31.8
32.5
34.0
36.8
37.4
10.5
12.5
13.0
15.4
17.5
18.0
20.2
22.5
22.9
25.1
27.4
27.9
29.9
32.3
32.8
34.8
37.2
37.8

85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
85.2
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1
73.1

9.98
12.2
12.8
14.9
17.3
17.8
19.7
22.2
22.7
24.5
27.1
27.6
29.4
32.0
32.6
34.2
36.9
37.5
10.7
12.6
13.1
15.6
17.7
18.1
20.4
22.6
23.0
25.3
27.5
28.0
30.2
32.4
32.9
35.1
37.3
37.9

81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
81.2
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6

10.2
12.4
12.9
15.1
17.4
17.9
19.9
22.3
22.8
24.8
27.2
27.7
29.6
32.1
32.7
34.5
37.1
37.6
10.9
12.7
13.2
15.8
17.8
18.2
20.7
22.7
23.1
25.5
27.6
28.1
30.4
32.5
33.0
35.3
37.5
38.0

Combi. : Combination
Temp. : Temperature

Outdoor Units

Heating Capacity
Indoor Air Temp.(CDB)
Inlet Water
Flow
Water
Combi.
Rate TC
Temp.
(%)
(C) (L/min) (kW)

15

20

25

50
30

35

40

200
384
480
200
384
480
200
384
480
200
384
480
200
384
480
200
384
480

72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9
72.9

16

18

20

21

22

24

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water TC
(kW) Temp. (kW)
(C)

Outlet
PI Water
(kW) Temp.
(C)

11.5
11.1
11.0
9.96
9.61
9.55
8.80
8.51
8.46
7.88
7.63
7.59
7.13
6.92
6.88
6.51
6.32
6.30

10.6
10.2
10.1
9.21
8.89
8.83
8.17
7.90
7.85
7.34
7.11
7.07
6.66
6.46
6.43
6.10
5.92
5.90

9.80
9.43
9.35
8.60
8.30
8.24
7.66
7.41
7.36
6.91
6.69
6.65
6.29
6.10
6.07
5.77
5.61
5.58

9.44
9.14
9.06
8.32
8.07
8.01
7.45
7.22
7.18
6.74
6.53
6.50
6.15
5.97
5.94
5.66
5.49
5.47

8.88
8.65
8.57
7.88
7.66
7.61
7.08
6.88
6.84
6.42
6.24
6.22
5.88
5.71
5.69
5.42
5.26
5.25

8.32
8.10
8.02
7.42
7.22
7.17
6.70
6.51
6.48
6.11
5.93
5.91
5.61
5.44
5.44
5.19
5.03
5.03

TC:Total Capacity(kW)
PI :Power Input(kW)

Outdoor Units

10.7
12.6
13.1
15.6
17.7
18.1
20.4
22.6
23.0
25.3
27.5
28.0
30.2
32.4
32.9
35.1
37.4
37.9

68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8
68.8

10.9
12.8
13.2
15.8
17.8
18.2
20.7
22.7
23.1
25.6
27.6
28.1
30.5
32.6
33.0
35.4
37.5
38.0

65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2
65.2

11.2
12.9
13.3
16.1
17.9
18.3
20.9
22.8
23.2
25.8
27.8
28.2
30.7
32.7
33.1
35.6
37.6
38.1

63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8
63.8

11.2
12.9
13.3
16.2
17.9
18.3
21.0
22.9
23.3
25.9
27.8
28.2
30.8
32.7
33.2
35.7
37.7
38.1

60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9
60.9

11.4
13.0
13.4
16.3
18.0
18.4
21.2
23.0
23.4
26.1
27.9
28.3
31.0
32.8
33.3
35.9
37.8
38.2

58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0
58.0

11.6
13.1
13.5
16.5
18.1
18.5
21.4
23.1
23.4
26.3
28.0
28.4
31.2
32.9
33.4
36.1
37.9
38.3

Combi. : Combination
Temp. : Temperature

50

7.3 Capacity Correction Factor


ARWN100LA2
Rate of change in cooling capacity
HU
50
40
30
20
10
7.5
0
L 0
0
7.5
10
20
30
40
HL

0.995
1.000
7.5
1.000
1.000
-

0.990
0.990
0.992
10
0.992
0.993
0.994
-

0.970
0.971
0.972
0.973
20
0.973
0.974
0.975
0.976
-

0.951
0.952
0.954
0.954
0.955
30
0.955
0.957
0.957
0.959
0.960
-

0.933
0.934
0.936
0.937
0.938
0.939
40
0.939
0.940
0.940
0.942
0.944
0.945

1.000
1.000
7.5
1.000
1.000
-

0.963
0.963
0.963
10
0.963
0.963
0.963
-

0.916
0.916
0.916
0.916
20
0.916
0.916
0.916
0.916
-

0.880
0.880
0.880
0.880
0.880
30
0.880
0.880
0.880
0.880
0.880
-

0.850
0.850
0.850
0.850
0.850
0.850
40
0.850
0.850
0.850
0.850
0.850
0.850

0.916
0.918
0.919
0.920
0.922
0.922
0.923
50
0.923
0.924
0.925
0.926
0.928
0.929

0.902
0.903
0.905
0.906
0.907
0.908
0.909
60
0.909
0.910
0.910
0.911
0.913
0.914

0.889
0.890
0.891
0.892
0.894
0.894
0.895
70
0.895
0.896
0.896
0.897
0.899
0.900

0.876
0.877
0.878
0.879
0.881
0.881
0.882
80
0.882
0.883
0.883
0.884
0.885
0.887

0.864
0.865
0.866
0.867
0.868
0.868
0.869
90
0.869
0.870
0.870
0.872
0.873
0.874

0.824
0.824
0.824
0.824
0.824
0.824
0.824
50
0.824
0.824
0.824
0.824
0.824
0.824

0.803
0.803
0.803
0.803
0.803
0.803
0.803
60
0.803
0.803
0.803
0.803
0.803
0.803

0.784
0.784
0.784
0.784
0.784
0.784
0.784
70
0.784
0.784
0.784
0.784
0.784
0.784

0.767
0.767
0.767
0.767
0.767
0.767
0.767
80
0.767
0.767
0.767
0.767
0.767
0.767

0.752
0.752
0.752
0.752
0.752
0.752
0.752
90
0.752
0.752
0.752
0.752
0.752
0.752

0.852
0.853
0.854
0.855
0.856
0.857
0.858
100
0.858
0.858
0.859
0.860
0.861
0.862

0.841
0.842
0.843
0.844
0.845
0.846
0.846
110
0.846
0.847
0.847
0.848
0.850
0.851

0.831
0.832
0.833
0.834
0.835
0.835
0.836
120
0.836
0.836
0.837
0.838
0.839
0.840

Rate of change in heating capacity


HU
50
40
30
20
10
7.5
0
L 0
0
7.5
10
20
30
40
HL

1. Symbols
HU : Level difference between indoor and outdoor units where indoor unit in inferior position (m)
HL : Level difference between indoor and outdoor units where indoor unit in superior position (m)
L : Equivalent pipe length (m)
: Capacity correction factor
2. These figures illustrate the rate of change in capacity of a standard indoor unit system at maximum load under standard conditions.
(Moreover, under partial load conditions there is only a minor deviation from the rate of change in capacity shown in the above figures.)
3. With this outdoor unit, evaporating pressure constant control when cooling, and condensing pressure constant control when heating is carried out.
4. If heat insulation of piping is insufficient, heat loss will become larger and capacity will decrease
5. Method of calculating cooling / heating capacity : maximum cooling / heating capacity of outdoor units
= cooling / heating capacity of outdoor units obtained from capacity table X capacity correction factor due to piping length to the farthest indoor unit
6. Assume equivalent pipe length of Y branch to be 0.5 m, that of header to be 1.0 m, calculation purposes.
7. When overall equivalent pipe length is 90 m or more, the diameter of the main gas and liquid pipes.
: ARWN100LA2 gas pipe 22.2 25.4
liquid pipe 9.52 12.7
8. Read cooling / heating capacity rate of change in the above figures based on the following equivalent length.
: overall equivalent length = (equivalent length of main pipe) X correction factor + (equivalent length after first branching)
overall equivalent pipe length
< 90 m
90 m
1.0
0.5
1.0
0.2

correction factor
cooling
heating

Ex)
Equivalent pipe
length 70 m

Indoor unit
Indoor unit

Outdoor
HU=10m
Equivalent pipe
length 40 m

51

(Cooling) Overall equivalent length =70 m x 0.5 + 40 m = 75 m


The correction factor in cooling capacity when HU = 10 m is thus approximately
0.887
(Heatng) Overall equivalent length =70 m x 0.2 + 40 m = 54 m
The correction factor in heating capacity when HU = 10 m is thus approximately
0.813

Outdoor Units

ARWN200LA2
Rate of change in cooling capacity
HU
50
40
30
20
10
7.5
0
L 0
0
7.5
10
20
30
40
HL

0.995
1.000
7.5
1.000
1.000
-

0.990
0.990
0.992
10
0.992
0.993
0.994
-

0.969
0.971
0.972
0.973
20
0.973
0.974
0.975
0.976
-

0.950
0.952
0.953
0.954
0.955
30
0.955
0.956
0.957
0.958
0.960
-

0.932
0.934
0.935
0.937
0.937
0.938
40
0.938
0.940
0.940
0.942
0.943
0.945

0.916
0.917
0.918
0.920
0.921
0.922
0.923
50
0.923
0.924
0.924
0.926
0.927
0.929

0.901
0.903
0.904
0.905
0.907
0.907
0.908
60
0.908
0.909
0.909
0.911
0.912
0.913

0.888
0.889
0.890
0.891
0.893
0.893
0.894
70
0.894
0.895
0.895
0.897
0.898
0.899

0.875
0.876
0.877
0.878
0.880
0.880
0.881
80
0.881
0.882
0.882
0.883
0.885
0.886

0.863
0.864
0.865
0.866
0.867
0.867
0.868
90
0.868
0.869
0.869
0.871
0.872
0.873

0.851
0.852
0.853
0.854
0.855
0.856
0.856
100
0.856
0.857
0.858
0.859
0.860
0.861

1.000
1.000
7.5
1.000
1.000
-

0.999
0.999
0.999
10
0.999
0.999
0.999
-

0.944
0.944
0.944
0.944
20
0.944
0.944
0.944
0.944
-

0.901
0.901
0.901
0.901
0.901
30
0.901
0.901
0.901
0.901
0.901
-

0.867
0.867
0.867
0.867
0.867
0.867
40
0.867
0.867
0.867
0.867
0.867
0.867

0.840
0.840
0.840
0.840
0.840
0.840
0.840
50
0.840
0.840
0.840
0.840
0.840
0.840

0.816
0.816
0.816
0.816
0.816
0.816
0.816
60
0.816
0.816
0.816
0.816
0.816
0.816

0.795
0.795
0.795
0.795
0.795
0.795
0.795
70
0.795
0.795
0.795
0.795
0.795
0.795

0.777
0.777
0.777
0.777
0.777
0.777
0.777
80
0.777
0.777
0.777
0.777
0.777
0.777

0.761
0.761
0.761
0.761
0.761
0.761
0.761
90
0.761
0.761
0.761
0.761
0.761
0.761

0.747
0.747
0.747
0.747
0.747
0.747
0.747
100
0.747
0.747
0.747
0.747
0.747
0.747

0.840
0.841
0.842
0.843
0.844
0.844
0.845
110
0.845
0.846
0.846
0.847
0.848
0.849

0.830
0.831
0.832
0.833
0.834
0.834
0.835
120
0.835
0.835
0.836
0.837
0.838
0.839

Rate of change in heating capacity


HU
50
40
30
20
10
7.5
0
L 0
0
7.5
10
20
30
40
HL

1. Symbols
HU : Level difference between indoor and outdoor units where indoor unit in inferior position (m)
HL : Level difference between indoor and outdoor units where indoor unit in superior position (m)
L : Equivalent pipe length (m)
: Capacity correction factor
2. These figures illustrate the rate of change in capacity of a standard indoor unit system at maximum load under standard conditions.
(Moreover, under partial load conditions there is only a minor deviation from the rate of change in capacity shown in the above figures.)
3. With this outdoor unit, evaporating pressure constant control when cooling, and condensing pressure constant control when heating is carried out.
4. If heat insulation of piping is insufficient, heat loss will become larger and capacity will decrease
5. Method of calculating cooling / heating capacity : maximum cooling / heating capacity of outdoor units
= cooling / heating capacity of outdoor units obtained from capacity table X capacity correction factor due to piping length to the farthest indoor unit
6. Assume equivalent pipe length of Y branch to be 0.5 m, that of header to be 1.0 m, calculation purposes.
7. When overall equivalent pipe length is 90 m or more, the diameter of the main gas and liquid pipes.
: ARWN200LA2
gas pipe 28.58 31.8
liquid pipe 12.7 15.88
8. Read cooling / heating capacity rate of change in the above figures based on the following equivalent length.
: overall equivalent length = (equivalent length of main pipe) X correction factor + (equivalent length after first branching)
overall equivalent pipe length
< 90 m
90 m
1.0
0.5
1.0
0.3

correction factor
Cooling
Heating

Ex)
Equivalent pipe
length 70 m

Indoor unit
Indoor unit

Outdoor
HU=10m
Equivalent pipe
length 40 m

Outdoor Units

(Cooling) Overall equivalent length =70 m x 0.5 + 40 m = 75 m


The correction factor in cooling capacity when HU = 10 m is thus approximately
0.886
(Heatng) Overall equivalent length =70 m x 0.3 + 40 m = 61 m
The correction factor in heating capacity when HU = 10 m is thus approximately
0.814

52

ARWN300LA2
Rate of change in cooling capacity
HU
50
40
30
20
10
7.5
0
L 0
0
7.5
10
20
30
40
HL

0.994
1.000
7.5
1.000
1.000
-

0.989
0.990
0.991
10
0.991
0.992
0.992
-

0.971
0.973
0.973
0.974
20
0.974
0.975
0.976
0.977
-

0.954
0.956
0.957
0.958
0.959
30
0.959
0.960
0.960
0.962
0.963
-

0.939
0.940
0.941
0.943
0.943
0.944
40
0.944
0.945
0.945
0.947
0.948
0.950

0.924
0.925
0.926
0.927
0.929
0.929
0.930
50
0.930
0.931
0.931
0.933
0.934
0.935

1.000
1.000
7.5
1.000
1.000
-

1.000
1.000
1.000
10
1.000
1.000
1.000
-

1.000
1.000
1.000
1.000
20
1.000
1.000
1.000
1.000
-

0.973
0.973
0.973
0.973
0.973
30
0.973
0.973
0.973
0.973
0.973
-

0.924
0.924
0.924
0.924
0.924
0.924
40
0.924
0.924
0.924
0.924
0.924
0.924

0.886
0.886
0.886
0.886
0.886
0.886
0.886
50
0.886
0.886
0.886
0.886
0.886
0.886

0.911
0.912
0.913
0.914
0.916
0.916
0.917
60
0.917
0.918
0.918
0.919
0.921
0.922

0.899
0.900
0.901
0.902
0.903
0.903
0.904
70
0.904
0.905
0.905
0.907
0.908
0.909

0.887
0.888
0.889
0.890
0.891
0.891
0.892
80
0.892
0.893
0.893
0.895
0.896
0.897

0.876
0.877
0.878
0.879
0.880
0.880
0.881
90
0.881
0.882
0.882
0.883
0.884
0.885

0.865
0.866
0.867
0.868
0.869
0.869
0.870
100
0.870
0.871
0.871
0.872
0.873
0.874

0.855
0.856
0.857
0.858
0.859
0.859
0.860
110
0.860
0.860
0.861
0.862
0.863
0.864

0.855
0.855
0.855
0.855
0.855
0.855
0.855
60
0.855
0.855
0.855
0.855
0.855
0.855

0.829
0.829
0.829
0.829
0.829
0.829
0.829
70
0.829
0.829
0.829
0.829
0.829
0.829

0.806
0.806
0.806
0.806
0.806
0.806
0.806
80
0.806
0.806
0.806
0.806
0.806
0.806

0.787
0.787
0.787
0.787
0.787
0.787
0.787
90
0.787
0.787
0.787
0.787
0.787
0.787

0.770
0.770
0.770
0.770
0.770
0.770
0.770
100
0.770
0.770
0.770
0.770
0.770
0.770

0.754
0.754
0.754
0.754
0.754
0.754
0.754
110
0.754
0.754
0.754
0.754
0.754
0.754

0.845
0.846
0.847
0.848
0.849
0.849
0.850
120
0.850
0.850
0.851
0.852
0.853
0.853

Rate of change in heating capacity


HU
50
40
30
20
10
7.5
0
L 0
0
7.5
10
20
30
40
HL

1. Symbols
HU : Level difference between indoor and outdoor units where indoor unit in inferior position (m)
HL : Level difference between indoor and outdoor units where indoor unit in superior position (m)
L : Equivalent pipe length (m)
: Capacity correction factor
2. These figures illustrate the rate of change in capacity of a standard indoor unit system at maximum load under standard conditions.
(Moreover, under partial load conditions there is only a minor deviation from the rate of change in capacity shown in the above figures.)
3. With this outdoor unit, evaporating pressure constant control when cooling, and condensing pressure constant control when heating is carried out.
4. If heat insulation of piping is insufficient, heat loss will become larger and capacity will decrease
5. Method of calculating cooling / heating capacity : maximum cooling / heating capacity of outdoor units
= cooling / heating capacity of outdoor units obtained from capacity table X capacity correction factor due to piping length to the farthest indoor unit
6. Assume equivalent pipe length of Y branch to be 0.5 m, that of header to be 1.0 m, calculation purposes.
7. When overall equivalent pipe length is 90 m or more, the diameter of the main gas and liquid pipes.
: ARWN300LA2
gas pipe 34.9 38.1
liquid pipe 15.88 19.05
8. Read cooling / heating capacity rate of change in the above figures based on the following equivalent length.
: overall equivalent length = (equivalent length of main pipe) X correction factor + (equivalent length after first branching)
overall equivalent pipe length
< 90 m
90 m
1.0
0.5
1.0
0.4

correction factor
Cooling
Heating

Ex)
Equivalent pipe
length 70 m

Indoor unit
Indoor unit

Outdoor
HU=10m
Equivalent pipe
length 40 m

53

(Cooling) Overall equivalent length =70 m x 0.5 + 40 m = 75 m


The correction factor in cooling capacity when HU = 10 m is thus approximately
0.897
(Heatng) Overall equivalent length =70 m x 0.4 + 40 m = 68 m
The correction factor in heating capacity when HU = 10 m is thus approximately
0.834

Outdoor Units

ARWN400LA2
HU
50
40
30
20
10
7.5
0
L 0
0
7.5
10
20
30
40
HL

0.992
1.000
7.5
1.000
1.000
-

0.988
0.989
0.990
10
0.990
0.991
0.991
-

0.973
0.974
0.975
0.976
20
0.976
0.977
0.977
0.978
-

0.959
0.960
0.961
0.961
0.962
30
0.962
0.963
0.964
0.965
0.966
-

0.945
0.946
0.947
0.948
0.949
0.950
40
0.950
0.950
0.951
0.952
0.953
0.954

0.932
0.933
0.934
0.935
0.936
0.937
0.937
50
0.937
0.938
0.939
0.940
0.941
0.942

0.920
0.922
0.923
0.924
0.925
0.925
0.926
60
0.926
0.927
0.927
0.928
0.929
0.930

0.910
0.911
0.912
0.913
0.914
0.914
0.915
70
0.915
0.916
0.916
0.917
0.918
0.919

0.899 0.889
0.900 0.890
0.901 0.891
0.902 0.892
0.903 0.893
0.903 0.893
0.904 0.894
80 90
0.904 0.894
0.905 0.895
0.905 0.895
0.906 0.896
0.907 0.897
0.908 0.898

0.880
0.881
0.881
0.882
0.883
0.883
0.884
100
0.884
0.885
0.885
0.886
0.887
0.888

0.870
0.871
0.872
0.873
0.874
0.874
0.875
110
0.875
0.875
0.876
0.877
0.877
0.878

0.862 0.853
0.862 0.854
0.863 0.855
0.864 0.855
0.865 0.856
0.865 0.856
0.866 0.857
120 130
0.866 0.857
0.866 0.858
0.867 0.858
0.867 0.859
0.868 0.860
0.869 0.860

0.845
0.846
0.846
0.847
0.848
0.848
0.849
140
0.849
0.849
0.849
0.850
0.851
0.852

0.837
0.838
0.838
0.839
0.840
0.840
0.841
150
0.841
0.841
0.841
0.842
0.843
0.844

0.829 0.818
0.830 0.819
0.831 0.820
0.831 0.820
0.832 0.821
0.832 0.821
0.833 0.822
160 175
0.833 0.822
0.833 0.822
0.834 0.822
0.834 0.823
0.835 0.824
0.836 0.825

Rate of change in heating capacity


HU
50
40
30
20
10
7.5
0
L 0
0
7.5
10
20
30
40
HL

1.000
1.000
7.5
1.000
1.000
-

1.000
1.000
1.000
10
1.000
1.000
1.000
-

1.000
1.000
1.000
1.000
20
1.000
1.000
1.000
1.000
-

1.000
1.000
1.000
1.000
1.000
30
1.000
1.000
1.000
1.000
1.000
-

1.000
1.000
1.000
1.000
1.000
1.000
40
1.000
1.000
1.000
1.000
1.000
1.000

1.000
1.000
1.000
1.000
1.000
1.000
1.000
50
1.000
1.000
1.000
1.000
1.000
1.000

1.000
1.000
1.000
1.000
1.000
1.000
1.000
60
1.000
1.000
1.000
1.000
1.000
1.000

1.000
1.000
1.000
1.000
1.000
1.000
1.000
70
1.000
1.000
1.000
1.000
1.000
1.000

1.000
1.000
1.000
1.000
1.000
1.000
1.000
80
1.000
1.000
1.000
1.000
1.000
1.000

1.000
1.000
1.000
1.000
1.000
1.000
1.000
90
1.000
1.000
1.000
1.000
1.000
1.000

1.000
1.000
1.000
1.000
1.000
1.000
1.000
100
1.000
1.000
1.000
1.000
1.000
1.000

1.000
1.000
1.000
1.000
1.000
1.000
1.000
110
1.000
1.000
1.000
1.000
1.000
1.000

1. Symbols
HU : Level difference between indoor and outdoor units where indoor unit in inferior position (m)
HL : Level difference between indoor and outdoor units where indoor unit in superior position (m)
L : Equivalent pipe length (m)
: Capacity correction factor
2. These figures illustrate the rate of change in capacity of a standard indoor unit system at maximum load under standard conditions.
(Moreover, under partial load conditions there is only a minor deviation from the rate of change in capacity shown in the above figures.)
3. With this outdoor unit, evaporating pressure constant control when cooling, and condensing pressure constant control when heating is carried out.
4. If heat insulation of piping is insufficient, heat loss will become larger and capacity will decrease
5. Method of calculating cooling / heating capacity : maximum cooling / heating capacity of outdoor units
= cooling / heating capacity of outdoor units obtained from capacity table X capacity correction factor due to piping length to the farthest indoor unit
6. Assume equivalent pipe length of Y branch to be 0.5 m, that of header to be 1.0 m, calculation purposes.
7. When overall equivalent pipe length is 90 m or more, the diameter of the main gas and liquid pipes.
: ARWN400LA2
gas pipe 41.3 41.3
liquid pipe 19.05 22.2
8. Read cooling / heating capacity rate of change in the above figures based on the following equivalent length.
: overall equivalent length = (equivalent length of main pipe) X correction factor + (equivalent length after first branching)
overall equivalent pipe length
< 90 m
90 m
1.0
1.0
1.0
0.4

correction factor
Cooling
Heating

Ex)
Equivalent pipe
length 70 m

Indoor unit
Indoor unit

Outdoor
HU=10m
Equivalent pipe
length 40 m

Outdoor Units

(Cooling) Overall equivalent length =70 m x 1.0 + 40 m = 110 m


The correction factor in cooling capacity when HU = 10 m is thus approximately
0.874
(Heatng) Overall equivalent length =70 m x 0.4 + 40 m = 68 m
The correction factor in heating capacity when HU = 10 m is thus approximately
1.000

54

8. Operation Limits
Cooling

Heating

Inlet water temperature (C)

Inlet water temperature (C)

45
40
35
30
25
20
15
10

45
40
35
30
25
20
15
10

10

15

20

25

30

Indoor temperature (CWB)

10

15

20

25

30

Indoor temperature (CDB)

Range for continuous

Range for operation

Range for pull down operation

Range for warming up operation

Notes:
These figures assume the following operating conditions:
Equivalent piping length:7.5m
Level difference:0m

55

Outdoor Units

9. Sound Levels
Unit:dB(A)
Model

50Hz

ARWN100LA2

51

ARWN200LA2

51

ARWN300LA2

53

ARWN400LA2

54

1m

Notes:
Data is valid at free field condition
Data is valid at nominal operating condition
Sound level will vary depending on a range of factors
such as the construction
(acoustic absorption coefficient) of particular room in
which the equipment is installed
The operating conditions are assumed to be
standard(ISO conditions)

ARWN300LA2

ARWN200LA2
80

80

70

70

70

NC-65
60
NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

20

10

NC-25
Approximate
Hearing
Threshold
63

NC-65
60
NC-60

50

NC-50

125

250

500

1000

2000

4000

8000

NC-45

40

NC-40
NC-35

30

NC-30

20

NC-20
NC-15

NC-55

10

NC-25
Approximate
Hearing
Threshold
63

Octave Band Center Frequency (Hz)

125

250

500

1000

2000

4000

Octave Band Center Frequency (Hz)

Octave Band Sound Pressure Level (dB re 20Pa )

80

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

ARWN100LA2

1m

NC-65
60
NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-25

20

NC-20

Approximate
Hearing

NC-15

Threshold

8000

10

63

NC-20
NC-15
125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

ARWN400LA2
80

Octave Band Sound Pressure Level (dB re 20Pa )

70

NC-65
60
NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-25

20
Approximate
Hearing
10

NC-20

Threshold
63

NC-15
125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

Outdoor Units

56

10. Accessories
Optional Accessories
No.

Name

Model
ARBLN01620

Y branch pipe

ARBLN03320
ARBLN07120
ARBLN14520
ARBL054
ARBL057

Header

ARBL104
ARBL107
ARBL1010
ARBL2010

57

Outdoor Units

Installation of Outdoor Units


1. Select the Installation Location
2. Installation Space
3. Water Control
4. Lifting Method
5. Installation
6. Refrigerant Piping System
7. Y Branch and Header Branch Pipe type
8. Leakage test and Vaccum
9. Electrical Wiring
10. Test Run
11. Site air conditioner/heater management sheet
12. Water cooling type cooling tower applied method
13. Caution For Refrigerant Leak

Installation

1. Select Installation Location


1.1 Precaution when selecting the installation location
Select space for installation outdoor unit, which will meet the following conditions.
With strength which bears weight of unit
With space for air passage and service work
Don't install the unit at the space where generation, inflow, stagnation, and leak of combustible gas is expected.
Avoid unit installation in a place where acidic solution and spray (sulfur) are often used.
Location with no leakage of combustible gas
Recommend the outdoor unit to be installed within 0~40C.
Location with installation or service work space (Refer to required space)
Do not use the outdoor unit under any special environment where oil, steam and sulfuric gas exist.
Install in a separate machine room not exposed to external air
- Establish an anti-freeze plan for the water supply when the product is stopped during the winter.
- Install the product so that the noise from the machine room is not transferred outdoors
The floor of the machine room must be water proof.
Drainage must be installed in the machine room to process the water drainage.
Install a floor slope to make the drainage smooth.
Avoid installing the outdoor unit in the location with following conditions.
Location where corrosive gas such as acidic gas is generated. (It may cause the refrigerant leakage by corrosion of
the pipe.)
Location where electromagnetic waves happen. (It may cause the abnormal operation by control parts disorder.)
Location to be able to leak the combustible gas
Location with carbon fiber or combustible dust.
Location with the combustible material like thinner or gasoline. (It may cause a fire by leaking the gas near the product.)

CAUTION
1. Do not install Multi V water outdoor. Always install indoor like machine room.
2. Inverter product may generate electric noise. Keep the body from computer, stereo etc. at
enough distance. Specially leave space from indoor remote controller to shoes electric devices
at the above 3m in weak electric wave area. Insert the power cable and other wire into separate
conduit.

Installation

2. Installation space
2.1 Individual Installation
Required the minimum space as shown below for installation and
check. If the space is not fit on this drawing, consult with LG.
1) In case of the water pipe passing over
the product
: Service area

100

20

(unit : mm)

547

Product
(Outdoor unit)

600

1120

Water pipe
installation
space

Service area
(Front)

300
Service area

100

350
300

772

H-Beam Support

<Top View>

<Front View>

2.2 Collective / Continuous Installation


Space required for collective installation and continuous installation as shown below considering passage for air
and people.
(Unit : mm)
20

: Service area

547

Product
(Outdoor unit)

600

Product
(Outdoor unit)

350

350
20

772

100

772

100

<Top view>

* In case of the water pipe passing side product, please make sufficient service place to avoid occurring
between water pipe and product side.

Installation

3. Water control
3.1 Water control
Keep the water temperature between 10~45C. Other it may cause the breakdown.
- Standard water supply temperature is 30C for air conditioning and 20C for heating.
Properly control the water velocity. Otherwise it may cause the noise, pipe vibration or pipe contraction, expansion
according to the temperature. Use the same water pipe size connected with the product or more.
Refer to the water source pipe diameter and water velocity table below. As the water velocity is fast, air bubble will
increase.
Diameter (mm)

Velocity range (m/s)

>125

2.1~2.7

50~100

1.2~2.1

25

0.6~1.2

Be careful of the water purity control. Otherwise it may cause the breakdown due to water pipe corrosion.
(Refer to 'Standard Table for Water Purity Control')
In case the water temperature is above 40C, it is good to prevent the corrosion by adding the antifreeze agent.
Install the pipe, valve and gauge sensor in the space where it is easy to maintain. Install the water valve in the low position for drain, if required.
Be careful not to let air in. If so, the water velocity will be unstable in the circulation, pump efficiency will also decrease
and may cause the piping vibration. Therefore, install the air purge where it may generate the air.
Choose the following anti freezing methods. Otherwise, it will be dangerous for the pipe to break in the winter.
- Circulate the water with the pump before dropping the temperature.
- Keep the normal temperature by boiler.
- When the cooling tower is not operated for a long time, drain the water in the cooling tower.
- Use an anti-freeze.
- Refer to the additive amount about freezing temperature as in the table given below.

Anti freeze type

Minimum temperature for anti freezing


0

-5

-10

-15

-20

-25

Ethylene glycol (%)

12

20

30

Propylene glycol (%)

17

25

33

Methanol (%)

12

16

24

30

In addition to anti freeze, it may cause the change of the pressure in the water system and the low performance of the
product.
Make sure to use the closed cooling type tower.
When applying the open type cooling tower, use a middle heat exchanger to make the water supply system a closed
type system.

Installation

3.2 Standard table for water purity control


The water may contain many foreign substances and hence may influence the performance and lifetime of the product
due to the corrosion of the condenser and water pipe. (Use water source that complies with the below standard table for
water purity control.)
If you use water supply other than the tap water to supply the water for the cooling tower, you must do a water quality
inspection.
For closed type water cooling type water supply, the water quality must be controlled in accordance with the following
standard table.
If you do not control the water quality in accordance with the following standard water quality table, it can cause performance deterioration to the air conditioner and severe problem to the product
Items

Closed type

Effect

Circulating water

Supplemented water

Corrosion

Scale

pH(25C)

7.0~8.0

7.0~8.0

Conductivity

Below 30

Below 30

Chlorine ion

Below 50

Below 50

Sulfuric acid ion

Below 50

Below 50

Acid demand

Below 50

Below 50

Total hardness

Below 70

Below 70

Ca hardness

Below 50

Below 50

Ion silica

Below 30

Below 30

Fe

Below 1.0

Below 0.3

Copper

Below 1.0

Below 0.1

Sulfuric acid ion

Must not be detected Must not be detected

Ammonium ion

Below 0.3

Below 0.1

Residual chlorine

Below 0.25

Below 0.3

Free carbon dioxide

Below 0.4

Below 4.0

Stability index

[Reference]
(1) The O mark for corrosion and scale means that there is possibility of occurrence.
(2) When the water temperature is 40C or above or when uncoated iron is exposed to the water, it can result in corrosion.
Therefore adding anti-corrosion agent or removing the air can be very effective.
(3) In the closed type circuit using the closed type cooling tower, the cooling water and supplementing water must satisfy the
water quality criteria of closed type system in the table.
(4) Supplementing water and supplied water must be supplied with tap water, industrial water and underground water
excluding filtered water, neutral water, soft water etc.
(5) 15 items in the table are general causes of corrosion and scale.

Installation

4. Lifting method
When carrying the unit suspended, pass the ropes under the unit and use the two suspension points each
at the front and rear.
Always lift the unit with ropes attached at fours points so that impact is not applied to the unit.
Attach the ropes to the unit at an angle of 40 or less

Sub line

A 40 or less
B Rope supporter

CAUTION
Do not have only one person carry product if it is more than 20kg.
PP bands are used to pack some products. Do not use them as a means for transportation because they
are dangerous.
Tear the plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging bag may suffocate children to death.
When carrying in outdoor unit, be sure to support it at four points. Carrying in and lifting with 3-point support may make outdoor unit unstable, resulting in a fall of it.
When carrying with the forklift, be careful not to drop the product.

Installation

5. Installation
5.1 Location of anchor bolt
(Unit: mm)

59
50

599

13

658

The location of
anchor bolt

WARNING
Be sure to install unit in a place strong enough to withstand its weight.
Any lack of strength may cause unit to fall down, resulting in a personal injury.
Have installation work in order to protect against a strong wind and earthquake. Any installation deficiency may cause unit to fall down, resulting in a personal injury.
Especially take care for support strength of the floor surface, water drain processing (processing of
water flown out from the outdoor unit during operation) and paths of the pipe and wiring when making
a base support.

Installation

5.2 Preparation of Piping


Main cause of gas leakage is defect in flaring work. Carry out correct flaring work in the following procedure.

1) Cut the pipes and the cable.


Use the accessory piping kit or the pipes purchased
locally.
Measure the distance between the indoor and the outdoor unit.
Cut the pipes a little longer than measured distance.
Cut the cable 1.5m longer than the pipe length.

Copper
tube

90

Slanted Uneven Rough

Pipe
Reamer

2) Burrs removal
Completely remove all burrs from the cut cross section
of pipe/tube.
Put the end of the copper tube/pipe to downward direction as you remove burrs in order to avoid to let burrs
drop in the tubing.

Point down

3) Flaring work
Handle

Carry out flaring work using flaring tool as shown below.


Pipe
Indoor unit
[kW(Btu/h]
Gas
Liquid
<5.6(19,100) 12.7 6.35
<16.0(54,600) 15.88 9.52
<22.4(76,400) 19.05 9.52

"A"
Gas
1.6~1.8
1.6~1.8
1.9~2.1

Liquid
1.1~1.3
1.5~1.7
1.5~1.7

Bar

Bar

"A"

Cone
Copper pipe
Clamp handle

Firmly hold copper tube in a bar(or die) as indicated


dimension in the table above.

4) Check

Red arrow mark

Smooth all round


Inside is shining without scratches.

Compare the flared work with figure below.


If flare is noted to be defective, cut off the flared section
and do flaring work again.

= Improper flaring =

Even length
all round

Yoke

Inclined Surface Cracked Uneven


damaged
thickness

Installation

4) Pipe connection
1. Follow the pipe path. Bend the pipe more than 3 times in 1 location and do not bend in the opposite direction. (This will
strengthen the pipe.)
2. After deforming the pipe, align the union fitting and center of the pipe, and tighten it with the wrench.
3. Connect the pipe to the service valve of the outdoor unit.
4. After finishing the piping work, check if there is any gas leakage
5. For the flare nut, always use the material that complies with KS B 0206 or better.
6. After completing the connection of the pipe, vacuum dry the indoor unit and the connecting pipe.
For the vacuum drying, you must use service ports of both the gas and liquid pipes.

Pipe Size
(mm)
6.35
9.52
12.7
15.88
19.05

Tightening Torque
(Nm)
18~25
34~42
55~66
63~82
99~121

(kgfcm)
180~250
340~420
550~660
630~820
990~1,210

CAUTION
When using two wrenches, tighten at regulated torque
* For the pipe connection, use the method of connecting the end of the pipe to the branch pipe. The refrigerant pipe
coming out from the outdoor unit is branched out at the end and is individually connected to the indoor unit.

WARNING
Always be careful not to leak the refrigerant during the welding.
When the refrigerant is combusted, it generates a toxic poisonous gas.
Do not execute the welding work in a closed location.
Always do a leakage test after welding the pipes.

Cut both the pipe and the valve with a


cutter to suit the length
(Don't cut the length of less than 70mm)

Open status when both the pipe and


the valve are in a straight line.
CLOSE

OPEN

WARNING
After completing work, securely tighten both service ports and caps so that gas does not leak.

Installation

* High/low pressure side is the ball valve that is opened and closed
by 1/4 rotation
Pipe joint (auxiliary parts): Securely perform brazing with a nitrogen blow into the service valve port.(Releasing pressure : 0.02
MPa or less)
Flare nut: Loose or tighten flare nut by using the wrench with
both ends. Coat the flare connection part with oil for the compressor.
Cap: Remove caps and operate valve, etc. After operation,
always reattach caps (tightening torque of valve cap: 25Nm
(250kg-cm) or more). (Don't remove the internal part of the port)
Service port: Make the refrigerant pipe vacuum and charge it
using the service port. Always reattach caps after completing
work (tightening torque of service cap: 14Nm (140kg-cm) or
more).
Liquid pipe
Ball Valve(Liquid Pipe)
Gas pipe
Elbow joint (field supply)

Elbow
Ball Valve(Gas Pipe)

CAUTION
After installing the pipe, block the pipe escape of front and side panel. (It can cause mouse or other animals to enter and
cause damage to the wire.)

5) Heat Insulation
1. Use the heat insulation material for the refrigerant
piping which has an excellent heat-resistance (Over
120C)
2. When installing in a humid environment, use thicker
heat insulation material.
* Consult with LG on detailed technical specification.

Fastening band
(accessory)

Refrigerant piping
Indoor unit
Thermal insulator
(accessory)

Installation

6) Standard refrigerant pipe EPDM heat insulation material thickness


Classification
Liquid
pipe

Gas
pipe

6.35
9.52
Above 12.7
9.52
12.7
15.88
19.05
22.22
25.4
28.58
31.75
34.9
38.1
44.45

Air conditioned location


Note1) General location Note1) Special location

Non-air conditioned location


Note3) General location Note4) Negative condition

Above 9t

Above 9t

Above 9t

Above 9t

Above 13t

Above 13t

Above 13t

Above 13t

Above 13t

Above 19t

Above 19t
Above 25t

Above 19t

Above 25t

Above 25t

* Note 1) General location: When the pipe passes through indoors in which the indoor unit is operated
- Apartment, classroom, office, mall, hospital, office-tel etc.
Note 2) Special location
1. When the location is air conditioned but has severe temperature/humidity difference due to high ceiling
- Church, auditorium, theater, lobby etc.
2. When the location is air conditioned but the internal temperature/humidity of the ceiling finishing is high
- Bathroom/swimming pool locker room etc. (Building with roof ceiling of sandwich assembly type)
Note 3) General location: When the pipe passes indoors where the indoor unit is not operated
- Hall way etc. (Dormitory, school, office-tel)
Note 4) Negative condition: When below conditions 1 and 2 are met.
1. When the pipe passes indoors where the indoor unit is not operated
2. When the humidity is high, regionally, and there is no air flow in the pipe passing area
- When installing the outdoor unit within the outdoor pipe tray or at a location where it is ok to have
freezes, apply 13t.
- If you are not sure with the selection of heat insulation material, coordinate with the supervision or HQ.
- The thickness of the above heat insulation material is based on the heat conductivity of 0.088W/mC.

Installation

10

7) Connection of high/low pressure common pipe


1. For the high/low pressure common pipe, connect both master outdoor unit and slave outdoor units to the pipe by using
elbows.
2. For cutting the pipe, connect the high/low pressure common
pipe after removing burrs, dusts and foreign material within
the pipe. Otherwise, the product may not operate due to
sludge within the pipe.

Slave
Outdoor Unit

3. For the working part leakage test, apply the nitrogen gas
pressure of 3.8MPa (38.7kgf/cm2).

Master
Outdoor Unit

4. The vacuum criteria is to maintain the vacuum level to less


than 5 Torr 1 hour after reaching 5 Torr. (Execute the vacuum work again when it is below the criteria.)

2 Outdoor Units

5. Open the valve with the hexagon wrench.

8) Connecting branch pipe between outdoor units


Combination specification

Connecting
branch pipe

Gas pipe

Do not cut for


70mm or less

Liquid pipe

Execute the welding


while pouring
nitrogen
Outdoor pipe
Outdoor pipe

ARCNN20

* Install the branch pipe between outdoor units so


that the outlet pipe is parallel to the surface.

Main pipe

Main pipe

Horizontal installation
Location when viewed from B
Horizontal surface

A. Outdoor unit side


B. Connecting outdoor unit side

CAUTION
When installing the branch pipe vertically between the outdoor units, the refrigerant can be uneven
between the outdoor units, leading to compressor burn and reduced capacity

11

Installation

8) Installation of water pipe


1. Water pipe system diagram
The water pressure resistance of the water pipe system of this product is 1.98MPa
When the water pipe passes indoors, make sure to execute heat insulation on the pipe so that water drops do not form on the
outer side of the water pipe.
The size of the drain pipe must be equal to or larger than the diameter of the connecting product.
- Always install a trap so that the drained water does not back flush.
Always install a strainer (50Mesh or above) at the entrance of the water pipe. (When sand, trash, rusted pieces get mixed into
the water supply, it can cause problems to the product due to corrosion.)
- The ON/OFF valve blocks the water supply to the outdoor unit that is not operating to save the pump power. Select appropriate on whether to install this or not for the site.
Install a pressure gauge at the inlet and outlet of the water pipe.
Flexible joints must be installed not to cause any leakage from the vibration of pipes.
Install a service port to clean the heat exchanger at the each end of the water inlet and outlet.
For the components of the water pipe system, always use components above the designed water pressure.
Pressure gauge
Water pipe
outlet

Gate valve

Service port

Water pipe
Inlet

Strainer
Gate valve

Service port

Drain line

Condensed
water drain

CAUTION
Do not directly connect the drain outlet to the water pipe outlet.
(It can cause problems to the product.)

2. Water pipe connection


The water pipe should be the same size of the connection on the product or more.
Be sure to install the insulation material in the water pipe inlet/outlet to prevent water drop, freeze and to save energy.
(Use the above 20mm thickness Pe insulation material.)
Tightly connect the socket to the water pipe refer to below table for recommended specification.
(Too much torque may cause the damage of the facility.)

Installation

12

Pipe thickness

Shear stress

Tensile stress

Bending moment

mm

inch

(kN)

(kgf)

(kN)

(kgf)

(N.m)

(kgf.m)

12.7

1/2

3.5

350

2.5

250

20

23

19.05

3/4

12

1200

2.5

250

20

25.4

11.2

1120

400

31.8

1 1/4

14.5

1450

6.5

38.1

1 1/2

16.5

1.7

9.5

50.8

21.5

2.2

13.5

1.4

Torque
(N.m)

(kgf.m)

3.5

115

11.5

45

4.5

155

15.5

650

87.5

8.75

265

26.5

0.95

155

16

350

35.5

255

26

600

61

Water pipe outlet


Water pipe
connection 3
Water pipe inlet

13

Installation

6. Refrigerant piping system


6.1 Y branch method
6.1.1 When installing 1 outdoor unit
independently

Indoor unit
direction

: Outdoor unit
: 1st branch (Y branch)
: Indoor units
: Indoor unit

Outdoor unit A ~ 1st branch B:


Main pipe diameter
Outdoor unit capacity
10 HP
20 HP

Liquid pipe (mm)


9.52
12.7

Below H 50 m

Ex) 5 indoor units connected

L Below 150 m
Below 40 m

Gas pipe (mm)


22.2
28.58

Refrigerant pipe diameter from


branch to branch (B,C,D)
Gas pipe
Total capacity of indoor units con- Liquid pipe
(mm)
(mm)
nected to after branching (kW)
< 5.6
6.35
12.7
< 16
9.52
15.88
< 22.4
9.52
19.05
< 33
9.52
22.2
< 47
12.7
28.58
< 71
15.88
28.58
< 104
19.05
34.9
104
19.05
41.3
For the first branch pipe (B), use the branch pipe
that fits the main pipe diameter (A).

Below 15 m

Total pipe length =


A+B+C+D+a+b+c+d+e 300m
Longest pipe length (Top pipe length)
A + B + C + D + e 150 m(175 m)
Longest pipe length after 1st branching
B + C + D + e 40 m
High/Low difference (Outdoor unit Indoor unit)
H
H 50 m(40m: When the outdoor unit is low)
High/Low difference (Indoor unit Indoor unit)
h
h 15 m
L

WARNING
When the pipe diameter (B) connected after 1st branching is larger than the main pipe diameter (A), Install the pipe
with the pipe diameter (B) after 1st branching that is the same as the main pipe diameter (A).
Ex) When connecting with 120% of the indoor unit to 10 HP
1) Outdoor unit main pipe diameter: 22.2 (Gas pipe) / 9.52(Liquid pipe)
2) Pipe diameter after 1st branching by 120% indoor unit combination : 28.58 (Gas pipe) / 12.7 (Liquid pipe)
Therefore set the pipe diameter (B) after 1st branching to 22.2 (Gas pipe) / 952 (Liquid pipe) of main pipe diameter (A).
When the pipe distance corresponding to the farthest indoor unit from the outdoor unit is 90m or above, you must
change the main pipe diameter according to the outdoor unit capacity in accordance with the following table. (This
applies to both the liquid and gas pipes.)
Gas Pipe
10 HP ...........................................22.2 25.4
20 HP ...........................................28.58 31.8

Installation

Liquid Pipe
10 HP...........................................9.52 12.7
20 HP...........................................12.7 15.88

14

6.1.2 When installing 1 outdoor units


Ex) 5 indoor units connected

Slave

: Outdoor unit
: 1st branch

Master

: Indoor units
Below 10m

Slave outdoor unit ~ Connecting


branch pipe (E): Pipe diameter
between outdoor units (E)
9.52/12.7

Low/high pressure
common pipe

22.2/28.58

Liquid pipe (mm)


15.88
19.05

19.05

Gas pipe (mm)


34.9
41.3

Liquid pipe
(mm)

Gas pipe
(mm)

6.35
9.52
9.52
9.52
12.7
15.88
19.05
19.05

12.7
15.88
19.05
22.2
28.58
28.58
34.9
41.3

Total refrigerant pipe length =


A + B + C + D + a + b + c + d + e 300 m
Longest pipe length (Top pipe length)
A + B + C + D + e 150 m(175 m)
Longest pipe length after 1st branching
B + C + D + e 40 m
High/Low difference (Outdoor unit Indoor unit)
H
H 50 m(40m: When the outdoor unit is low)
High/Low difference (Indoor unit Indoor unit)
h
h 15 m
High/Low difference (Indoor unit Indoor unit)
h1
h 2m
L

Refrigerant pipe diameter from branch


to branch (B, C, D)
Total capacity of indoor
units connected to after
branching (kW)
< 5.6
< 16
< 22.4
< 33
< 47
< 71
< 104
104

Below 40 m

Below 15 m

Connecting branch pipe E ~ 1st


branch part B: Main pipe diameter (A)
Outdoor unit capacity
30 HP
40 HP

L Below 150 m

Below H 50 m

: Connecting branch pipe between outdoor units


Connecting branch pipe between outdoor
units: ARRCN20( )

Liquid pipe (mm) Gas pipe (mm)

Indoor unit
direction

Below 2m

: Indoor unit direction

For the first branch pipe (B), use the branch pipe
that fits the main pipe diameter (A).

WARNING
When the pipe diameter (B) connected after 1st branching is larger than the main pipe diameter (A), Install the pipe with the pipe diameter (B)
after 1st branching that is the same as the main pipe diameter (A).
Ex) When connecting with 120% of the indoor unit to 10 HP.
1) Outdoor unit main pipe diameter: 22.2 (Gas pipe) / 9.52(Liquid pipe)
2) Pipe diameter after 1st branching by 120% indoor unit combination : 28.58 (Gas pipe) / 12.7 (Liquid pipe)
Therefore set the pipe diameter (B) after 1st branching to 22.2 (Gas pipe) / 9.52 (Liquid pipe) of main pipe diameter (A).
When the pipe distance corresponding to the farthest indoor unit from the outdoor unit is 90m or above, you must change the main pipe diameter according to the outdoor unit capacity in accordance with the following table. (This applies to both the liquid and gas pipes.)
Gas Pipe
Liquid Pipe
30 HP ...........................................37.9 38.1
30 HP...........................................15.88 19.06
40 HP ...........................................41.3
40 HP...........................................19.05 22.2

15

Installation

6.2 Header branch method


6.2.1 When installing 1 outdoor unit independently
Ex) 6 indoor units connected
Outdoor unit
Header branch
Indoor unit
Seal

Outdoor unit capacity


10 HP
20 HP

Liquid pipe (mm)


9.52
12.7

Below H 50 m

Outdoor unit A ~ Header branch


part B: Main pipe diameter (A)

L Below 150 m

Gas pipe (mm)


22.2
28.58

Below 40 m

Below 15 m

Total refrigerant pipe length = A +a +b +c +d +e +f 300 m


Longest pipe length (Top pipe length)
A +f 150 m(175 m)
Longest pipe length after 1st branching
f 40 m
High/Low difference (Outdoor unit <-> Indoor unit)
H
H 50 m(40m: When the outdoor unit is low)
High/Low difference (Indoor unit <-> Indoor unit)
h
h 15 m
L

WARNING
For the pipe length after the header branch (a~f), it is recommended to install the unit so that the difference of the pipe distance connected to the indoor unit is minimized.
The large difference in pipe distance can cause performance difference between indoor units.
The indoor unit must be installed at a lower location than the header branch.
After the header branch, you cannot use the Y branch and header branch.
When the pipe distance corresponding to the farthest indoor unit from the outdoor unit is 90m or above, you must change the
main pipe diameter according to the outdoor unit capacity in accordance with the following table.
(This applies to both the liquid and gas pipes.)

Installation

16

6.2.2 When installing 2 outdoor units


Ex) 6 indoor units connected
: Outdoor unit

Slave

: Header branch
Master

: Indoor unit
: Seal

Below 2m

Slave outdoor unit ~ Connecting


branch unit E: Pipe diameter
between outdoor units
Liquid pipe (mm) Gas pipe (mm)
9.52/12.7

Low/high pressure
common pipe

22.2/28.58

Below 10m

L Below 150 m
Below H 50 m

: Connecting branch pipe between outdoor units


Connecting branch pipe between outdoor
units: ARRCN20( )

Below 40 m

Below 15 m

19.05

Connecting branch pipe E ~ Header branch part B: Main pipe diameter (A)
Outdoor unit capacity
30 HP
40 HP

Liquid pipe (mm)


15.88
19.05

Gas pipe (mm)


34.9
41.3

Total refrigerant pipe length = A + B + C + D + a + b + c + d + e 300 m


Longest pipe length (Top pipe length)
A +f 150 m(175 m)
Longest pipe length after 1st branching
f 40 m
High/Low difference (Outdoor unit Indoor unit)
H
H 50 m(40m: When the outdoor unit is low)
High/Low difference (Indoor unit Indoor unit)
h
h 15 m
High/Low difference (Indoor unit Indoor unit)
h1
h1 2 m
L

WARNING
For the pipe length after the header branch (a~f), it is recommended to install the unit so that the difference of the pipe distance connected to the indoor unit is minimized.
The large difference in pipe distance can cause performance difference between indoor units.
The indoor unit must be installed at a lower location than the header branch.
After the header branch, you cannot use the Y branch and header branch.
When the pipe distance corresponding to the farthest indoor unit from the outdoor unit is 90m or above, you must change the
main pipe diameter according to the outdoor unit capacity in accordance with the following table. (This applies to both the liquid and gas pipes.)
Gas Pipe
30 HP ...........................................37.9 38.1
40 HP ...........................................41.3

17

Liquid Pipe
30 HP...........................................15.88 19.06
40 HP...........................................19.05 22.2

Installation

6.3 Y/Header branch method


6.3.1 When installing 1 outdoor unit independently

Outdoor unit A ~ 1st Y branch


part B: Main pipe diameter (A)
Outdoor unit capacity
10 HP
20 HP

Liquid pipe (mm)


9.52
12.7

L Below 150 m
Below 40 m

Gas pipe (mm)


22.2
28.58

Refrigerant pipe diameter from


branch to branch (B, C)
Total capacity of indoor units con- Liquid pipe
(mm)
nected to after branching (kW)
< 5.6
6.35
< 16
9.52
< 22.4
9.52
< 33
9.52
< 47
12.7
< 71
15.88
< 104
19.05
104
19.05

Gas pipe
(mm)
12.7
15.88
19.05
22.2
28.58
28.58
34.9
41.3

h Below 15 m

: Outdoor unit
: 1st Y branch
: 2nd Y branch
: Indoor unit
: Header branch
: Seal

Below H 50 m

Ex) 5 indoor units connected

Total pipe length


=A +B +C +a +b +c +d +e 300 m
Longest pipe length (Top pipe length)
A +B +b,A +C +e 150 m(175 m)
Longest pipe length after 1st branching
B +b,C +e 40 m
High/Low difference (Outdoor unit Indoor unit)
H
H 50 m(40m: When the outdoor unit is low)
High/Low difference (Indoor unit Indoor unit)
h
h 15 m
L

* For the first branch pipe (B), use the branch pipe
that fits the main pipe diameter (A)

WARNING
When the pipe diameter (B) connected after 1st branching is larger than the main pipe diameter (A), Install the pipe
with the pipe diameter (B) after 1st branching that is the same as the main pipe diameter (A). Ex) When connecting
with 120% of the indoor unit to 10 HP.
1) Outdoor unit main pipe diameter: 22.2 (Gas pipe) / 9.52 (Liquid pipe)
2) Pipe diameter after 1st branching by 120% indoor unit combination : 28.58 (Gas pipe) / 12.7 (Liquid pipe)
Therefore set the pipe diameter (B) after 1st branching to 22.2 (Gas pipe) / 952 (Liquid pipe) of main pipe diameter (A).
For the pipe length after the header branch (c~e), it is recommended to install the unit so that the difference of the pipe
distance connected to the indoor unit is minimized.
The large difference in pipe distance can cause performance difference between indoor units.
The indoor unit must be installed at a lower location than the header branch.
After the header branch, you cannot use the Y branch and header branch.
When the pipe distance corresponding to the farthest indoor unit from the outdoor unit is 90m or above, you must
change the main pipe diameter according to the outdoor unit capacity in accordance with the following table. (This
applies to both the liquid and gas pipes.)
Gas Pipe
10 HP ...........................................22.2 25.4
20 HP ...........................................28.58 31.8

Installation

Liquid Pipe
10 HP...........................................9.52 12.7
20 HP...........................................12.7 15.88

18

6.3.2 When installing 2 outdoor units


Ex) 5 indoor units connected
Slave

Master

Below 2m

Below 10m

Liquid pipe (mm) Gas pipe (mm)


9.52/12.7

H Below 50 m

Slave outdoor unit ~ Connecting


branch pipe G: Pipe diameter
between outdoor units (E)
19.05

Connecting branch pipe G ~ 1st Y


branch part B: Main pipe diameter (A)
Liquid pipe (mm)
15.88
19.05

Gas pipe (mm)


34.9
41.3

Liquid pipe
(mm)
6.35
9.52
9.52
9.52
12.7
15.88
19.05
19.05

Gas pipe
(mm)
12.7
15.88
19.05
22.2
28.58
28.58
34.9
41.3

Total refrigerant pipe length =


A + B + C + a + b + c + d + e 300 m
Longest pipe length (Top pipe length)
A +B +b,A +C +e 150 m(175 m)
Longest pipe length after 1st branching
B +b,C +e 40 m
High/Low difference (Outdoor unit Indoor unit)
H
H 50 m(40m: When the outdoor unit is low)
High/Low difference (Indoor unit Indoor unit)
h
h 15 m
High/Low difference (Indoor unit Indoor unit)
h1
h 2m
L

Refrigerant pipe diameter from branch


to branch (B, C)
Total capacity of indoor units
connected to after branching (kW)
< 5.6
< 16
< 22.4
< 33
< 47
< 71
< 104
104

Below 40 m

Low/high pressure
common pipe

22.2/28.58

Outdoor unit capacity


30 HP
40 HP

L Below 150 m

h Below 15 m

: Outdoor unit
: 1st Y branch
: 2nd Y branch
: Indoor unit
: Header branch
: Seal
: Connecting branch pipe between outdoor units
Connecting branch pipe between outdoor units:
ARRCN20( )

For the first branch pipe (B), use the branch pipe
that fits the main pipe diameter (A).

WARNING
When the pipe diameter (B) connected after 1st branching is larger than the main pipe diameter (A), Install the pipe
with the pipe diameter (B) after 1st branching that is the same as the main pipe diameter (A).
Ex) When connecting with 120% of the indoor unit to 10 HP.
1) Outdoor unit main pipe diameter: 22.2 (Gas pipe) / 9.52 (Liquid pipe)
2) Pipe diameter after 1st branching by 120% indoor unit combination : 28.58 (Gas pipe) / 12.7 (Liquid pipe)
Therefore set the pipe diameter (B) after 1st branching to 22.2 (Gas pipe) / 952 (Liquid pipe) of main pipe diameter (A).
For the pipe length after the header branch (c~e), it is recommended to install the unit so that the difference of the pipe
distance connected to the indoor unit is minimized.
The large difference in pipe distance can cause performance difference between indoor units.
The indoor unit must be installed at a lower location than the header branch.
After the header branch, you cannot use the Y branch and header branch.
When the pipe distance corresponding to the farthest indoor unit from the outdoor unit is 90m or above, you must
change the main pipe diameter according to the outdoor unit capacity in accordance with the following table. (This
applies to both the liquid and gas pipes.)
Gas Pipe
30 HP ...........................................37.9 38.1
40 HP ...........................................41.3

19

Liquid Pipe
30 HP...........................................15.88 19.06
40 HP...........................................19.05 22.2

Installation

6.4 Oil trap application method between outdoor units


Because of the possibility of oil being accumulated in the outdoor unit that has stopped, when there is a height difference between
outdoor unit pipes or if the pipe distance between the outdoor units is over 2m, you must always apply an oil trap. (But, the oil trap
between outdoor units is limited to 1 time and is only applied to the gas pipe.)
If the pipe distance between the outdoor units is 2m or below, and if the location of the main pipe is lower than that of the outdoor
unit and if the location of the main pipe is lower than that of the outdoor unit, the oil trap does not have to be applied.
If the location of the main pipe is higher than the location of the outdoor unit, be careful since the oil can be accumulated in the
stopped outdoor unit.
If there is high/low difference between the outdoor unit pipes, oil can be accumulated to the outdoor unit on the lower location until
the unit stops.

When pipe distance between the outdoor units


is 2m or less

Example of incorrect installation


Location of main pipe

High/Low difference
between the outdoor units

Oil is accumulated on the


outdoor unit because it cannot be poured out from the
bottom of the pipe.
Location of
outdoor unit

Location of
main pipe

2m or less

When pipe distance between the outdoor units


exceed 2m

/Low difference
etween outdoor
unit pipes

Because the oil flow to the right pipe, oil gets accumulated on
the outdoor unit on the lower side until the outdoor unit stops.

Example of correct installation


Oil trap
Over 200mm
Location of
main pipe

2m or less
Over 2m

Oil trap
High/Low difference
between outdoor
unit pipes

Oil trap
Location of
main pipe

Location of
outdoor unit
2m or less

Location of main pipe

Installation

20

6.5 Indoor unit connection


Ex) 5 indoor units connected

L Below 150 m
Below 40 m

h Below 15 m

H Below 50 m

: Outdoor unit
: 1st Y branch
: 2nd Y branch
: Indoor unit
: Header branch
: Seal

Refrigerant pipe diameter from branch to indoor unit (a, b, c, d, e)


Outdoor unit capacity (kW)
5.6
< 16.0

21

Liquid pipe (mm)


6.35
9.52

Gas pipe (mm)


12.7
15.88

Installation

6.6 Calculation of amount of refrigerant


The calculation of the additional charge should take account of the diameter and length of the pipe.

Additional refrigerant
charge (kg)

Total length of liquid pipe (m)


:22.2 mm

x 0.354(kg/m)

Total length of liquid pipe (m)


:19.05 mm

x 0.266(kg/m)

Total length of liquid pipe (m)


:15.88 mm

x 0.173(kg/m)

Total length of liquid pipe (m)


:12.7 mm

x 0.118(kg/m)

Total length of liquid pipe (m)


:9.52 mm

x 0.061(kg/m)

Total length of liquid pipe (m)


:6.35 mm

x 0.022(kg/m)

WARNING
Regulation for refrigerant leakage
: the amount of refrigerant leakage should satisfy the following equation for human safety.
Total amount of refrigerant in the system
Volume of the room at which indoor unit of the least capacity is installed

0.44 ( kg / m3)

If the above equation cannot be satisfied, the following steps must be followed.
- Selection of air conditioning system: Select one of the following
1. Installation of effective opening part: At the top and bottom of the door connecting the room to the outside, create an opening
with or without the door of with 0.15% of floor space or above.
2. Recheck of outdoor unit capacity and piping length
3. Reduction of the amount of refrigerant
4. Installation of 2 or more security devices (Alarm for gas leakage)
- Change indoor unit type
: Installation position should be over 2m from the floor (Wall mounted type cassette type)
- Adoption of ventilation system
Ventilation system prevents the refrigerant density from increasing when the refrigerant is leaked by the installation.
Ventilation system comes in two types; external air inflow type or exhaust type. External air inflow type is recommended due to
the characteristics of the refrigerant.
Always operate the ventilation system irrelevant from whether the air conditioner is used or not and whether the indoor or not.
When it is impossible to operate this and in case of a refrigerant leakage by the sensor, the ventilation system is automatically
operated.
- Limitation in piping work
: Prepare for earthquake and thermal stress
- Reduction of all refrigerant charge amount of the refrigerant facility (When calculated value exceeds 0.44kg/m3)
1. Shorten the refrigerant pipe length.
Change the location of the outdoor unit and shorten the length of the refrigerant pipe to reduce all refrigerant charge amount.
2. Distribute the outdoor unit to several units to reduce the refrigerant charge amount per outdoor unit. (Ex. 20 HP 1 unit
10 HP 2 units)

Installation

22

6.7 Refrigerant pipe fitting


6.7.1 Caution
1. Use the following materials for refrigerant piping.
Material: Seamless phosphorous deoxidized copper pipe
Wall thickness : Comply with the relevant local and national regulations for the designed pressure
3.8MPa. We recommend the following table as the minimum wall thickness.
Outer diameter
[mm]

6.35

9.52

12.7

15.88

19.05

22.2

25.4

28.58

31.8

34.9

38.1

41.3

Minimum
thickness [mm]

0.8

0.8

0.8

0.99

0.99

0.99

0.99

0.99

1.1

1.21

1.35

1.43

2. Commercially available piping often contains dust and other materials. Always blow it clean with a dry inert gas.
3. Use care to prevent dust, water or other contaminants from entering the piping during installation.
4. Reduce the number of bending portions as much as possible, and make bending radius as big as possible.
5. Always use the branch piping set shown below, which are sold separately.

Header

Y branch
4 branch

7 branch

10 branch

ARBLN01620

ARBLN03320

ARBL054

ARBL057

ARBL1010

ARBLN07120

ARBLN14520

ARBL104

ARBL107

ARBL2010

6. If the diameters of the branch piping of the designated refrigerant piping differs, use a pipe cutter to cut the connecting section and then use an adapter for connecting different diameters to connect the piping.
7. Always observe the restrictions on the refrigerant piping (such as rated length, difference in height, and piping diameter).
Failure to do so can result in equipment failure or a decline in heating/cooling performance.
8. A second branch cannot be made after a header. (These are shown by
.)

A
B

A To Outdoor Unit
B Sealed Piping

9. The system will stop due to an abnormality like excessive or insufficient refrigerant. At such a time, always properly charge
the unit. When servicing, always check the notes concerning both the piping length and the amount of additional refrigerant.
10. Never perform a pump down. This will not only damage the compressor but also deteriorate the performance.
11. Never use refrigerant to perform an air purge. Always evacuate using a vacuum pump.
12. Always insulate the piping properly. Insufficient insulation will result in a decline in heating/cooling performance, drip of condensate and other such problems.
13. When connecting the refrigerant piping, make sure the service valves of the outdoor unit is completely closed (the factory
setting) and do not operate it until the refrigerant piping for the outdoor and indoor units has been connected, a refrigerant
leakage test has been performed and the evacuation process has been completed.
14. Always use a non-oxidizing brazing material for brazing the parts and do not use flux. If not, oxidized film can cause clogging or damage to the compressors and flux can harm the copper piping or refrigerant oil.

23

Installation

6.7.2 Y Branch and Header Fitting


Y branch
A To Outdoor Unit
B

B To Branch Piping or Indoor Unit

Ensure that the branch pipes are attached horizontally or vertically (see the diagram below.)
Facing
downwards

Horizontal
plane

Facing
upwards

Within +/- 10

A
Viewed from point A
in direction of arrow

Within 3

Within 3

There is no limitation on the joint mounting configuration.


If the diameter of the refrigerant piping selected by the procedures described is different from the size of the
joint, the connecting section should be cut with a pipe cutter.
Branch pipe should be insulated with the insulator in each kit.

Tape
(field supply)

Liquid and Gas


pipe joints

Insulator
(included with kit)

Insulator for
field piping

A
A To outdoor unit

Header

B To indoor unit

The indoor unit having larger capacity must be


installed closer to
than smaller one.
If the diameter of the refrigerant piping selected
by the procedures described is different from the
size of the joint, the connecting section should be
cut with a pipe cutter.

Pipe cutter
When the number of pipes to be connected is
smaller than the number of header branches,
install a cap to the unconnected branches.

Installation

24

When the number of indoor units to be connected to the branch pipes is less than the number of branch
pipes available for connection then cap pipes should be fitted to the surplus branches.

B
Piched pipe

Fit branch pipe lie in a horizontal plane.


Horizontal plane

View from point B in the direction of the arrow


Header should be insulated with the insulator in each kit.

Insulate the header using


the insulation
material attached to the
branch pipe kit
as shown in the figure.

Joints between branch and pipe should be sealed with the tape included in each kit.
Tape

Insulator
Insulator of field pipe

Any cap pipe should be insulated using the insulator provided with each kit and then taped as described
above.
Insulator for cap pipe

Cap pipe

25

Tape

Installation

6.7.3 Thermal insulation of refrigerant piping


Be sure to give insulation work to refrigerant piping by covering liquid pipe and gas pipe separately with
enough thickness heat-resistant polyethylene, so that no gap is observed in the joint between indoor unit
and insulating material, and insulating materials themselves. When insulation work is insufficient, there is a
possibility of condensation drip, etc. Pay special attention to insulation work to ceiling plenum.
B

Heat
insulation
material
Outer
covering

A Heat insulation material

Adhesive + Heat - resistant polyethylene foam +


Adhesive tape
Indoor
Vinyl tape
Floor exposed Water-proof hemp cloth + Bronze asphalt
Water-proof hemp cloth + Zinc plate + Oily paint
Outdoor

Note:
When using polyethylene cover as covering material, asphalt roofing shall not be required.

B Pipe
C Outer covering
(Wind the connection part and cutting part of
heat insulation material with a finishing tape.)

Do not insulate gas or low pressure pipe and liquid or high


pressure pipe together.

B
F

Bad example

Be sure to fully insulate connecting portion.


A

A Liquid pipe
B Gas pipe
C Power lines
D Finishing tape

E Insulating material

F Transmission lines
A These parts are not insulated.

Power lines

Transmission lines

D
A

Good example
A Liquid pipe

Separation

B Gas pipe
C Power lines
D Insulating material
E Transmission lines

Penetrations
Outer wall

Inner wall (concealed)


C
A

Outer wall (exposed)

D
E

Floor (fireproofing)
D

Roof pipe shaft

G
F

Penetrating portion on fire


limit and boundary wall
J

D
B

H
A

1m

Installation

1m

Sleeve
Heat insulating material
Lagging
Caulking material
Band
Waterproofing layer
Sleeve with edge
Lagging material
Mortar or other incombustible caulking
Incombustible heat insulation material
When filling a gap with mortar, cover the
penetration part with steel plate so that
the insulation material will not be caved in.
For this part, use incombustible materials
for both insulation and covering.(Vinyl
covering should not be used.)

26

7. Y branch pipe and header branch pipe type


7.1 Y branch pipe
[unit:mm]

Models

Gas pipe

Liquid pipe

ARBLN01620

ARBLN03320

ARBLN07120

ARBLN14520

27

Installation

7.2 Header
[unit:mm]

Models

Gas pipe
12.7

Liquid pipe
12.7
6.35

4 branch

15.88

15.88

6.35

9.52

9.52
12.7

19.05

ARBL054
OD19.05
12.7

15.88 12.7

OD12.7

15.88

12.7

9.52

9.52

6.35

9.52

6.35

15.88

7 branch

12.7

19.05

ARBL057
OD19.05 15.88 12.7

OD12.7

12.7

15.88

15.88

19.05

6.35

4 branch

9.52

9.52

6.35

9.52

12.7

28.58

ARBL104

OD28.58

OD12.7

22.2
15.88

12.7
15.88

9.52

6.35

9.52

6.35

19.05

7 branch

9.52

12.7

28.58

ARBL107

OD28.58

22.2

OD12.7

12.7

15.88

15.88

19.05

6.35

9.52

9.52

6.35

10 branch
28.58

12.7

9.52

ARBL1010

OD28.58
12.7
15.88

22.2

OD12.7
15.88

19.05

9.52

9.52

6.35

31.8

10 branch

6.35
15.88

38.1

19.05

9.52

ARBL2010

OD38.1

Installation

34.9 28.58

OD19.05

15.88

28

8. Leakage test and vacuum


8.1 Leak test
Leak test should be made by pressurizing nitrogen gas to 3.8 MPa(38.7kgf/cm2). If the pressure does not drop for
24 hours, the system passes the test. If the pressure drops, check where the nitrogen leaks. For the test method,
refer to the following figure. (Make a test with the service valves closed. Be also sure to pressurize liquid pipe, gas
pipe and high/low pressure common pipe)
The test result can be judged good if the pressure has not be reduced after leaving for about one day after completion of nitrogen gas pressurization.

Main outdoor unit


Close

Gas pipe

Nitrogen gas
cylinder

Liquide pipe

Close

Liquid side
Indoor unit

Gas side

Note:
If the ambient temperature differs between the time when pressure is applied and when the pressure drop is
checked, apply the following correction factor
There is a pressure change of approximately 0.1 kg/cm2 (0.01 MPa) for each 1C of temperature difference.
Correction= (Temp. at the time of pressurization Temp. at the time of check) X 0.1
For example: Temperature at the time of pressurization (3.8 MPa) is 27 C
24 hour later: 3.73 MPa, 20C
In this case the pressure drop of 0.07 is because of temperature drop
And hence there is no leakage in pipe occurred.
Caution:
To prevent the nitrogen from entering the refrigeration system in the liquid state, the top of the cylinder must be
at higher position than the bottom when you pressurize the system.
Usually the cylinder is used in a vertical standing position.

29

Installation

8.2 Vacuum
Vacuum drying should be made from the service port provided on the outdoor units service valve to the vacuum pump commonly used for liquid pipe, gas pipe and high/low pressure common pipe. (Make Vacuum
from liquid pipe, gas pipe and high/low pressure common pipe with the service valve closed.)
* Never perform air purging using refrigerant.
Vacuum drying: Use a vacuum pump that can evacuate to -100.7kPa (5 Torr, -755mmHg).
1. Evacuate the system from the liquid and gas pipes with a vacuum pump for over 2 hrs and bring the system to -100.7kPa.
After maintaining system under that condition for over 1 hr, confirm the vacuum gauge rises. The system
may contain moisture or leak.
2. Following should be executed if there is a possibility of moisture remaining inside the pipe.
(Rainwater may enter the pipe during work in the rainy season or over a long period of time)
After evacuating the system for 2 hrs, give pressure to the system to 0.05MPa(vacuum break) with nitrogen gas and then evacuate it again with the vacuum pump for 1hr to -100.7kPa(vacuum drying). If the
system cannot be evacuated to -100.7kPa within 2 hrs, repeat the steps of vacuum break and its drying.
Finally, check if the vacuum gauge does not rise or not, after maintaining the system in vacuum for 1 hr.

Main outdoor unit


Close

Vacuum pump

Gas pipe

Liquide pipe

Close

Scale
Use a graviometer. (One that can
measure down to 0.1kg). If you are
unable to prepare such a high-precision
gravimeter you may use a charge
cylinder.

Liquid side
Indoor unit

Gas side

Note : Always add an appropriate amount of refrigerant. (For the refrigerant additional charge)
Too much or too little refrigerant will cause
trouble.

Vacuum should be done for 3 hours or more


after the pressure is under 0.5 torr.

WARNING
When installing and moving the air conditioner to another site, recharge after perfect evacuation.
- If a different refrigerant or air is mixed with the original refrigerant, the refrigerant cycle may malfunction and
the unit may be damaged.

Installation

30

9. Electrical Wiring
9.1 Areas of Caution
1. Follow ordinance of your governmental organization for technical standard related to electrical equipment,
wiring regulations and guidance of each electric power company.

WARNING
Be sure to have authorized Electrical engineers do electric work using special circuits in accordance
with regulations and this installation manual. If power supply circuit has a lack of capacity or electric
work deficiency, it may cause an electric shock or fire.
2. Install the outdoor unit transmission line away from the power source wiring so that it may not affected by
electric noise from the power source. (Do not run it through the same conduit.)
3. Be sure to provide designated grounding work to outdoor unit.

CAUTION
Be sure to correct the outdoor unit to earth. Do not connect earth line to any gas pipe, water pipe,
lightening rod or telephone earth line. If earth is incomplete, it may cause an electric shock.
4. Give some allowance to wiring for electrical part box of indoor and outdoor units, because the box is sometimes removed at the time of service work.
5. Never connect the main power source to terminal block of transmission line. If connected, electrical parts will
be burnt out.
6. Use 2-core shield cable for transmission line.(O mark in the figure below) If transmission lines of different
systems are wired with the same multiplecore cable, the resultant poor transmission and receiving will cause
erroneous operations. (
mark in the figure below)
7. Only the transmission line specified should be connected to the terminal block for outdoor unit transmission.
Outdoor Unit

Outdoor Unit

Indoor
Unit

Indoor
Unit

Remote
control

Indoor
Unit

Remote
control

Indoor
Unit

Remote
control

Remote
control

Outdoor Unit
Indoor
Unit

Indoor
Unit

Indoor
Unit

Remote
control

2-core shield cable

Remote
control

Indoor
Unit

Remote
control

Remote
control

Multi-core cable

WARNING
Use the 2-core shield cables for transmission lines. Never use them together with power cables.
The conductive shielding layer of cable should be grounded to the metal part of both units.
Never use multi-core cable
As this unit is equipped with an inverter, to install a phase leading capacitor not only will deteriorate
power factor improvement effect, but also may cause capacitor abnormal heating. Therefore, never
install a phase leading capacitor.
Keep power imbalance within 2% of the supply rating. Large imbalance will shorten the life of the
smoothing capacitor.
Introducing with a missing N-phase or with a mistaken N-phase will break the equipment.

31

Installation

9.2 Control Box and Wiring Location


- Unscrew all the screw, pull out the panel.
- Connect the transmission wire between outdoor unit and indoor unit,
the connection between outdoor unit and central controller system
pass through the sub PCB for central control.
- When connecting indoor unit with the shield cable, ground at the
grounding screw.
When connecting central controller with the shield cable, ground at
the grounding screw.
- Refer to next page about the distance between main power cable
and communication cable.
- Refer to 106 page about Auto-Addressing and Test Run.

Installation

Front Panel

32

9.3 Transmission and Power Lines


1) Transmission cable
Types : shielding wire CVVS or CPEVS
Diameter : over 1.25mm2
Insulation material : PVC
Maximum allowable temperature: 60C
Maximum allowable line length: under 300m

2) Remote control cable


Types : 3-core cable

3) Simple central control cable


Types : 4-core cable (Shielding wire)
Diameter : over 1.25mm2
Insulation material : PVC

4) Separation of transmission and power lines


If transmission and power lines are run alongside each other then here is a strong likelihood of operational
faults developing due to interference in the signal wiring caused by electrostatic and electromagnetic coupling.

Current capacity of power line

100V or more

Spacing

10A

300mm

50A

500mm

100A

1000mm

100A or more

1500mm

Note:
1. The figures are based on assumed length of parallel cabling up to 100m. For length in excess of 100m the
figures will have to be recalculated in direct proportion to the additional length of line involved.
2. If the power supply waveform continues to exhibit some distortion the recommended spacing in the table
should be increased.
If the lines are laid inside conduits then the following point must also be taken into account when grouping
various lines together for introduction into the conduits.
Power lines(including power supply to air conditioner) and signal lines must not be laid inside the same
conduit.
In the same way, when grouping the power lines and signal lines should not be bunched together.

CAUTION
If apparatus is not properly earthed then there is always a risk of electric shocks, the earthing of the
apparatus must be carried out by a qualified person.
Use a power wire pipe for the power wiring.

33

Installation

Example for mistake of wiring


Do not separately connect the power of the indoor unit.
3phase 4lines power cable
Transmission cable(3lines): wired remote controller
Single phase 60Hz 220V
Transmission cable(2lines Shield cable) : Indoor~ Outdoor unit

Single phase 60Hz 220V

Power supply
3phase 4lines
60Hz 380V

Breaker

CAUTION
Never install individual switch or individual outlet to cut the power connecting the indoor unit.

Installation

34

9.4 Dip switch setting


9.4.1 Location of setting switch
SW01B SW02B
7 segment
SW02B

SW01B

ON

ON

2 3 4

6 7

2 3 4

6 7

CAUTION
If the applicable dip switch is not set correctly,
the product may not operate properly.
9.4.2 Dip switch setting
1. Set the dip switch and turn on the power of the outdoor unit to check whether the set value is correctly entered
in the 7 segment.
2. This function is shown for only 2 seconds after the power is connected.

Check outdoor unit setting


The number on the 7 segment is displayed in order after the power is connected.
This number represents the setting condition.
Order

Number

Item

Model code

Total capacity in horsepower (Ex)

25

Normal mode display (If the dip switch is set incorrectly, it is not displayed.)

41

Refrigerant type (R410A)

Mode code
Model Code

Capacity

34

29

35

58

36

87

37

116

35

Refrigerant

R410A

Installation

Master indoor Setting


SW01B Setting

SW02B Setting

Remark

ON

ON

Normal mode at shipping


factory

2 3 4

6 7

2 3 4

6 7

Slave outdoor Setting (1 unit: master outdoor)


SW01B Setting

SW02B Setting

Remark

ON

ON

Normal mode at shipping


factory

2 3 4

6 7

2 3 4

6 7

ON

ON

Slave1 outdoor setting


(at the 2units)

2 3 4

Function

6 7

2 3 4

SW01B Setting

6 7

SW02B Setting

Remark

ON

ON

Standard mode at shipping


factory

Standard

2 3 4

6 7

2 3 4

6 7

2 3 4

6 7

2 3 4

6 7

ON

ON
Short Pipe Length

2 3 4

6 7

1
ON

ON
Long Pipe Length

Installation

2 3 4

6 7

36

Function

SW01B Setting

SW02B Setting

Remark

ON

ON

Standard mode at shipping


factory

longest Pipe
Length

2 3 4

6 7

2 3 4

6 7

2 3 4

6 7

2 3 4

6 7

ON

ON
Test mode
(Cooling)

2 3 4

6 7

1
ON

ON
Test mode
(Heating)

2 3 4

6 7

After the system turn on,


Dip Switch 7,12 are
completed is indicated on
7-Segment

ON

ON
Water temp
checking

2 3 4

6 7

2 3 4

6 7

2 3 4

6 7

2 3 4

6 7

2 3 4

6 7

2 3 4

6 7

ON

ON
COP checking
mode

Indoor unit
Forced Operation
(Cooling)

6 7

2 3 4

6 7

1
ON

ON

1
ON

ON

Indoor unit
Forced Operation
(Heating)

2 3 4

2 3 4

6 7

1
ON

ON
Forced Oil Return

37

2 3 4

6 7

Installation

Function

SW01B Setting

SW02B Setting

Remark

ON

ON
Vacuum Mode

Water Pipe
Solenoid Valve
220V Functions

2 3 4

6 7

2 3 4

6 7

ON

ON

For water pipe Solenoid


Valve 220V power

2 3 4

6 7

2 3 4

6 7

CAUTION
After operating the dip switch to set the additional function, you must reset the power of the main PCB to
reflect the changed function. (After recovering the dip switch to cancel the additional function, you must
reset the power of the main PCB to reflect the change.)
If the dip switch is not set accurately, it can have excessive load on the product operation.
Set the dip switch properly.

Installation

38

9.5 Indoor unit auto addressing


The address of the indoor units would be set by auto addressing.
1) Wait for 3 minutes after applying power supply (master and slave outdoor unit, indoor unit)
2) Press the switch of the outdoor unit (SW02V) for 5 seconds.
3) A "88" is indicated on 7-segment LED of the outdoor unit PCB.
4) For completing addressing, 2~7 minutes are required depending on numbers of indoor unit connection set.
5) Numbers of indoor unit connection set whose addressing is completed are indicated for 30 seconds on 7-segment LED
of the outdoor unit PCB.
6) After completing addressing, address of each indoor unit is indicated on the wired remote controller display window.
(CH01, CH02, CH03, .... CH06 : Indicated as number of indoor unit connection set.)

WARNING
When replacing the indoor unit PCB, you must execute the auto addressing again. Always execute
this with all the power of indoor units and outdoor units connected. If the power is not connected to
the indoor unit, it can generate an operation error.
When power is connected to the Multi V Water II for the first time, it will standby for more than 3 minutes to improve the indoor unit communication, and then the address must be set.

39

Installation

The Procedure of Automatic Addressing


Power On

Waiting 3 minutes

Press SW02V for 5 sec.

Auto addressing start

7-segment LED

= 88

Don't Press SW02V

Waiting about 2~7 minutes

7-segment LED
= 88

NO

Auto addressing setting end


Numbers of indoor unit connection set whose
addressing is completed are indicated for 30seconds
on 7-segment LED after completing setting

Check the connections


of transmission line

YES

OK

Installation

Indoor address number is displayed on wired remote control or


indoor unit display window. It is not an error message, will
disappeared when on/off button is pressed on remote control
ex) Display of 01, 02, ..., 15 means connection of 15 indoor
units and auto addressing is completed normally.

40

9.6 Group Number Setting of Indoor Units


Using the wired remote controller
1. Press Program button and Set/Clr button at the same time for 3 seconds.
2. The current group and the indoor unit numbers are indicated on the "88" of the wired remote control.
3. Set numbers by using the temperature adjust key.
AUTO SWING

OPERATION

SET TEMP
Room Temp

2ndF
Timer

Operation unit

On Off
Set no. Time 01

03

FAN SPEED

SUB FUNCTION

AUTO Heater Preheat


JET Defrost Humidify
SLo Filter Out door
ZONE
1 2 3 4

HI
MED
LO

Time

EX)

Program set
05

07

09

11

13

15

17

19

21

23

Group Room(Indoor Unit)


No. No.

4. Press Program button and Set/Clr button at the same time for
3 seconds.
Timer

Cancel

2ndF

Program

Week

Holiday
PLASMA
Set/Clr

Hour

41

Min

5. If transmit recognition data are received from the indoor unit,


it returns to the general operation mode.

RESET

Installation

10. Test Run


10.1 Water supply system test run
Before executing the test run for the product, you must first test the cooling water system.
The test run for the product must be executed after checking the flux and temperature of the cooling water
supplied.
Equipment design

Design the system including cooling tower, boiler, pump etc.


- Check the equipment capacity (Water flux, temperature control range).

Water pipe system installation

Install the water supply pipe and piping system parts.


- Connect the water supply pipe and install various valves and devices.

Water supply pipe and product


connection

Connect the water supply pipe to the inlet/outlet of the product so that the
water can be supplied to the product.

Water supply system test run

Execute water supply system test run


- The product does not operate but the pump and water supply equipment
will operate to flow the cooling water to the heat exchanger on the product
side.
- Flow the water to all water piping system to clean any alien particles inside
the pipes and execute an air purge to remove an air within the pipes to
make the water supply smoother.

Judging whether there is any


problem with the water supply

Execute the test of water supply system without operating the product.
- Check whether the unit outdoor unit inlet/outlet flux complies to the product
specification.
Standard product flux is 96LPM based on 10HP and 193LPM based on
20HP.
- Check the water supply temperature.

Execute the product test run

Installation

After checking the normal condition of the water supply, execute the test run
of the product.
To prevent the freezing of the heat exchanger when the refrigerant is discharged with the water supply blocked, discharge the refrigerant after supplying the water in the water supply line .

42

10.2 Precaution before test run


1

Check whether the air is completely removed and the water supply is flowing smoothly.

Check whether there is any refrigerant leakage of any disconnected or loose communication or power wire, or use
the electric wiring diagram to check the wiring connection condition.
Check whether the power and communication wire are connected.

Check whether the power cable R, S, T and N are correctly connected.


Check the insulation resistance with the DB mega tester device (DC 500V) between the power terminal block and
grounding, and check whether it is 2.0M or above when measured.
If the resistance is 2.0M or less, do not operate the product.
Precaution)
- Never check the insulation resistance for the terminal control board.
(The control board can be damaged.)
- If you leave the system turned off right after the installation or for a long period of time, the refrigerant gets accumulated within the compressor and the insulation resistance reduces to less than 2 M. When the insulation
resistance is 2 M or less, turn on the power and let the electricity be supplied to the crank case heater of the
compressor and let the refrigerant including the oil inside the compressor to evaporate.
Then the insulation resistance value will increase to more than 2.0 M.

Check whether the liquid and gas pipes are open.


Firmly close the wrench part cap of the service valve.

Precaution when blocking the water cooling type Multi V main power
- While using the product (Air conditioning season/Heating season), always connect the main power of the outdoor
unit.
- During the test run operation after installing the product or during the operation after blocking the outdoor unit
main power (Power outage etc.), you must always connect the power 6 hours prior to heating the crank case
heater. If the crank case is not preheated for more than 6 hours with the electric heater, it can cause a burn on
the compressor.
(Heating the bottom part of the compressor with the crank case heater is to evaporate the refrigerant included in
the oil inside the compressor.)

WARNING
Always check whether the water supply is flowing smoothly before the test run. (If sufficient amount
of water is not flowing, it can burn the product.)
During the initial test run after installing the product, leaving the product for more than 3 days or
after replacing the compressor, power must be connected 6 hours prior to the operation to heat the
compressor heater. (If the product is not heated sufficiently, it can burn the product.)

43

Installation

12.2 How to Cope with Abnormal Test Run


The phenomena from main component failure
Item

Phenomenon

Cause

Check and troubleshooting method

CH32

Check whether the water supply pump is


Water is not supplied or operating.
flux is low (During air
Check whether the water supply pipe is
conditioning operation)
clogged. (Strainer cleaning, valve lock,
valve error, air clog etc.)

CH180

Check whether the water supply pump is


Water is not supplied or operating.
flux is low (During heat- Check whether the water supply pipe is
ing operation)
clogged. (Strainer cleaning, valve lock,
valve error, air clog etc.)

Whether water is
supplied

When the water supply is not smoothly flowing, CH32 or CH180 error can occur.
Check whether water supply is flowing smoothly.

Installation

44

10.4 Self-Diagnosis Function


Error Indicator
This function indicates type of failure in self-diagnosis and occurrence of failure for air condition.
Error mark is displayed on display window of indoor units and wired remote controller, and 7-segment LED of outdoor unit
control board as shown in the table.
If more than two troubles occur simultaneously, low number of error code is first displayed.
After error occurrence, if error is released, error LED is also released simultaneously.

Error display method


1st and 2nd LED of 7-segment refers to the error number and the 3rd LED refers to the outdoor unit number.
Ex) 011: Error No. 1 of outdoor unit No. 1
011051: Error No. 105 of outdoor unit No. 1
Display
number
1
2
3

Indoor unit

4
5
6
7
9
10
11
211
212
231

Outdoor unit

232
241
242
251
252
261
262
281

45

Error item

Root cause of error

Indoor unit air temperature sensor error


Indoor unit pipe inlet temperature sensor error
Communication error between wired remote controller and indoor unit
Indoor unit drain error
Communication error between outdoor unit and
indoor unit
Indoor unit pipe outlet temperature sensor error
Different mode operation
Indoor unit EEPROM error

Indoor unit air temperature sensor disconnection or short circuit


Indoor unit pipe inlet temperature sensor disconnection or short circuit
Occurs when indoor unit communication signal is not received from the
wired remote controller
Drain pump and float switch error
When the indoor unit does not receive the outdoor communication signal
continuously for 5 minutes or more
Indoor unit pipe outlet temperature sensor disconnection or short circuit
When operated in different operating mode than the one first operated
Communication error between MICOM and EEPROM or when there is
no indoor unit EEPROM data
Indoor unit BLDC motor feedback signal error
When motor connector is removed or defective
Communication error between indoor unit/outdoor When the communication is working but cannot be called from the outunit
door unit (must be readdressed)
Master outdoor unit inverter compressor IPM fault Master outdoor unit inverter compressor drive IPM error
Slave outdoor unit inverter compressor IPM fault Slave outdoor unit inverter compressor drive IPM error
Master outdoor unit inverter compressor DC link
DC voltage is not charged after master outdoor unit operating relay is
under-voltage
turned on
Slave outdoor unit inverter compressor DC link
DC voltage is not charged after slave outdoor unit operating relay is
under-voltage
turned on
Master outdoor unit high pressure switch
Compressor maintenance by master outdoor unit high pressure switch
Master outdoor unit high pressure switch
Compressor maintenance by slave outdoor unit high pressure switch
Master outdoor unit input voltage overMaster outdoor unit input voltage of 487V or above or 270V or less
voltage/under-voltage
Slave outdoor unit input voltage overSlave outdoor unit input voltage of 487V or above or 270V or less
voltage/under-voltage
Master outdoor unit inverter compressor operation Initial operation failure due to master outdoor unit inverter compressor
failure error
error
Slave outdoor unit inverter compressor operation Initial operation failure due to slave outdoor unit inverter compressor error
failure error
Master outdoor unit inverter DC link over-voltage Compressor turned Off due to master outdoor unit inverter DC voltage
error
over-charge

Installation

Display
number
282
291
292
311
312
321
322
331
332

Outdoor unit

341
342
351
352
391
392
401
402
411
412
421
422
431
432
441
442
451
452
461
462

Installation

Error item
Slave outdoor unit inverter DC link over-voltage
error
Master outdoor unit inverter compressor over-current
Slave outdoor unit inverter compressor over-current
Master outdoor unit inverter CT under-current
error
Slave outdoor unit inverter CT under-current error
Master outdoor unit inverter compressor discharge
temperature over-rise
Slave outdoor unit inverter compressor discharge
temperature over-rise
Master outdoor unit static speed compressor discharge temperature over-rise
Slave outdoor unit static speed compressor discharge temperature over-rise
Master outdoor unit high pressure over-rise
Slave outdoor unit high pressure over-rise
Master outdoor unit low pressure over-drop.
Slave outdoor unit low pressure over-drop.
Communication error between master outdoor unit
PFC circuit and inverter board
Communication error between slave outdoor unit
PFC circuit and inverter board
Master outdoor unit inverter compressor CT sensor error
Slave outdoor unit inverter compressor CT sensor
error
Master outdoor unit inverter compressor discharge
temperature sensor error
Slave outdoor unit inverter compressor discharge
temperature sensor error
Master outdoor unit under-voltage sensor error
Slave outdoor unit under-voltage sensor error
Master outdoor unit over-voltage sensor error
Slave outdoor unit over-voltage sensor error
Master outdoor unit air temperature sensor error
Slave outdoor unit air temperature sensor error
Master outdoor unit heat exchange temperature
sensor (A) error
Slave outdoor unit heat exchange temperature
sensor (A) error
Master outdoor unit suction temperature sensor
error
Slave outdoor unit suction temperature sensor
error

Root cause of error


Compressor turned Off due to slave outdoor unit inverter DC voltage
over-charge
Master outdoor unit inverter compressor error or operating component
(IPM) error operation
Slave outdoor unit inverter compressor error or operating component
(IPM) error operation
Compressor turned off due to master outdoor unit inverter CT under-current
Compressor turned off due to slave outdoor unit inverter CT under-current
Compressor turned off due to master outdoor unit inverter compressor
discharge temperature over-rise
Compressor turned off due to slave outdoor unit inverter compressor discharge temperature over-rise
Compressor turned off due to master outdoor unit static speed compressor discharge temperature over-rise
Compressor turned off due to slave outdoor unit static speed compressor
discharge temperature over-rise
Compressor turned off due to master outdoor unit high pressure over-rise
Compressor turned off due to slave outdoor unit high pressure over-rise
Compressor turned off due to master outdoor unit low pressure over-drop.
Compressor turned off due to slave outdoor unit low pressure over-drop.
Master outdoor unit PFC MICOM or inverter MICOM error
Slave outdoor unit PFC MICOM or inverter MICOM error
Master outdoor unit inverter compressor current detection (CT) sensor
disconnection or short circuit
Slave outdoor unit inverter compressor current detection (CT) sensor disconnection or short circuit
Master outdoor unit inverter compressor discharge temperature sensor
disconnection or short circuit
Slave outdoor unit inverter compressor discharge temperature sensor disconnection or short circuit
Master outdoor unit under-voltage sensor disconnection or short circuit
Slave outdoor unit under-voltage sensor disconnection or short circuit
Master outdoor unit over-voltage sensor disconnection or short circuit
Slave outdoor unit over-voltage sensor disconnection or short circuit
Master outdoor unit air temperature sensor disconnection or short circuit
Slave outdoor unit air temperature sensor disconnection or short circuit
Master outdoor unit heat exchange temperature sensor (A) disconnection
or short circuit
Slave outdoor unit heat exchange temperature sensor (A) disconnection
or short circuit
Master outdoor unit suction temperature sensor disconnection or short circuit
Slave outdoor unit suction temperature sensor disconnection or short circuit

46

Display
number
471
472
481
482
491
492
501
502
51
521
522

Outdoor unit

53
541
542
601
602
701
702
731
732
741
742
861
862
1041
1042
1131
1132

47

Error item
Master outdoor unit static speed compressor discharge temperature sensor error
Slave outdoor unit static speed compressor discharge temperature sensor error
Master outdoor unit static speed compressor discharge temperature sensor error
Slave outdoor unit static speed compressor discharge temperature sensor error
Master outdoor unit heat exchanger temperature
sensor (B) error
Slave outdoor unit heat exchanger temperature
sensor (B) error
Master outdoor unit 3 phase power missing
Slave outdoor unit 3 phase power missing
Over-capacity
(Indoor unit capacity sum is excessive) connection
Communication error with master outdoor unit
inverter controller
Communication error with slave outdoor unit
inverter controller
Communication error with master outdoor unit
controller and indoor unit
Master outdoor unit 3 phase power reverse phase
Slave outdoor unit 3 phase power reverse phase
Master outdoor unit inverter PCB EEPROM error
Slave outdoor unit inverter PCB EEPROM error
Master outdoor unit static speed CT sensor error
Slave outdoor unit static speed CT sensor error
Master outdoor unit inverter PCB input instant
over-current (Peak)
Slave outdoor unit inverter PCB input instant overcurrent (Peak)
Master outdoor unit inverter PCB phase imbalance
Slave outdoor unit inverter PCB phase imbalance
Master outdoor unit master PCB EEPROM error

Root cause of error


Master outdoor unit static speed compressor discharge temperature sensor disconnection or short circuit
Slave outdoor unit static speed compressor discharge temperature sensor
disconnection or short circuit
Master outdoor unit static speed compressor discharge temperature sensor disconnection or short circuit
Slave outdoor unit static speed compressor discharge temperature sensor
disconnection or short circuit
Master outdoor unit heat exchanger temperature sensor (B) disconnection
or short circuit
Slave outdoor unit heat exchanger temperature sensor (B) disconnection
or short circuit
Master outdoor unit power line phase missing
Slave outdoor unit power line phase missing
Excessive connection of indoor unit connection display value (Different
from outdoor unit)
When the inverter controller signal is not received from the master outdoor unit inverter controller
When the inverter controller signal is not received from the slave outdoor
unit inverter controller
When the indoor unit control signal is not received from the master outdoor unit controller
Master outdoor unit 3 phase power reverse phase connection
Slave outdoor unit 3 phase power reverse phase connection
Master outdoor unit inverter PCB EEPROM ACCESS error
Slave outdoor unit inverter PCB EEPROM ACCESS error
Master outdoor unit static speed CT sensor disconnection or short circuit
Slave outdoor unit static speed CT sensor disconnection or short circuit
Master outdoor unit inverter PCB input instant over-current (Peak)
exceeded
Slave outdoor unit inverter PCB input instant over-current (Peak) exceeded
When the master outdoor unit inverter PCB input current is different

When the slave outdoor unit inverter PCB input current is different
Communication error between master outdoor unit master MICOM and
EEPROM or EEPROM missing
Slave outdoor unit master PCB EEPROM error
Communication error between slave outdoor unit master MICOM and
EEPROM or EEPROM missing
Communication error between master outdoor unit When signal from slave outdoor unit is not received from master outdoor
and outdoor unit
unit master MICOM
Communication error between slave outdoor unit When signal from slave outdoor unit is not received from slave outdoor
and outdoor unit
unit master MICOM
Master outdoor unit liquid pipe temperature sensor Master outdoor unit liquid pipe temperature sensor disconnection or short
error
circuit
Slave outdoor unit liquid pipe temperature sensor Slave outdoor unit liquid pipe temperature sensor disconnection or short
error
circuit

Installation

Display
number
1141
1142

Outdoor unit

1151
1152
151
1731
1732
180
181
182

Error item
Master outdoor unit over-cooling inlet temperature
sensor error
Slave outdoor unit over-cooling inlet temperature
sensor error
Master outdoor unit over-cooling outlet temperature sensor error
Slave outdoor unit over-cooling outlet temperature
sensor error
Outdoor unit 4 way valve switch failure
Master outdoor unit static speed compressor error
Slave outdoor unit static speed compressor error
Plate type heat exchanger freeze prevention
Water temperature sensor error
Communication error between MICOMs

Root cause of error


Master outdoor unit over-cooling inlet temperature sensor disconnection
or short circuit
Slave outdoor unit over-cooling inlet temperature sensor disconnection or
short circuit
Master outdoor unit over-cooling outlet temperature sensor disconnection
or short circuit
Slave outdoor unit over-cooling outlet temperature sensor disconnection
or short circuit
Outdoor unit 4 way valve switch error
Master outdoor unit static speed compressor burn, locking and over-current
Slave outdoor unit static speed compressor burn, locking and over-current
Plate type heat exchanger freeze prevention error
Water temperature sensor open/short
Communication error between main MICOM and sub MICOM

Refer to the troubleshooting guide of service technical manual for each error.

Installation

48

11. Site air conditioner/heater management sheet


Outdoor unit
model

Outdoor unit No.

Location

Zone

SVC Call

Additional refrigerant
(R410A)

kg

Combination percentage

Model :

Model :

Model :

Model :

Name :

Name :

Name :

Name :

Remote controller:

Remote controller:

Remote controller:

Remote controller:

[Diagram]
Ex)

49

[Check record]
Date/
Time

Error

Action
result

Checked
by

Date/
Time

Error

Action
result

Checked
by

Date/
Time

Error

Action
result

Checked
by

Date/
Time

Error

Action
result

Checked
by

Date/
Time

Error

Action
result

Checked
by

Date/
Time

Error

Action
result

Checked
by

Date/
Time

Error

Action
result

Checked
by

Date/
Time

Error

Action
result

Checked
by

Installation

12. Water cooling type cooling tower applied method


Open type
cooling tower
2nd side
1st side

Closed type
cooling tower

Heat exchange
[Open type cooling tower + Middle heat exchanger]
Heat exchanger is installed between the cooling
tower and outdoor unit system piping, and the temperature difference between 1st side and 2nd side
is maintained constantly

Installation

[Closed type cooling tower]


Cooling water of the cooling tower is supplied
directly to the outdoor unit system.

50

13. Caution For Refrigerant Leak


The installer and system specialist shall secure safety against leakage according to local regulations or standards.
The following standards may be applicable if local regulations are not available.

13.1 Introduction
Though the R410A refrigerant is harmless and incombustible itself , the room to equip the air conditioner should be large to
such an extent that the refrigerant gas will not exceed the limiting concentration even if the refrigerant gas leaks in the room.

Limiting concentration
Limiting concentration is the limit of Freon gas concentration where immediate measures can be taken without hurting human body when refrigerant leaks in the air. The limiting concentration shall be described in the
unit of kg/m3 (Freon gas weight per unit air volume) for facilitating calculation.
Limiting concentration: 0.44kg/m3(R410A)
Outdoor unit

(No.1 system)

Flow of
refrigerant

Indoor unit

Room where refrigerant leaks


(Refrigerant of the whole No.1
system flows out.)

13.2 Checking procedure of limiting concentration


Check limiting concentration along following steps and take appropriate measure depending on the situation.

Calculate amount of all the replenished refrigerant (kg) per each refrigerant
Amount of additional
Total amount of replenished
system. Amount of replenished
=
+
refrigerant per one outdoor
unit system

replenished refrigerant

Amount of replenished
refrigerant at factory shipment

Amount of additionally
replenished refrigerant
depending on piping
length or piping
diameter at customer

refrigerant in refrigerant
facility (kg)

Note : In case one refrigerant facility is


divided into 2 or more refrigerant
systems and each system is
independent, amount of replenished
refrigerant of each system shall be
adopted.

Calculate minimum room capacity


Calculate room capacity by regarding a portion as one room or the smaller room.
(2) With partition and with opening which serve as
(1) Without partition
passage of air to adjoining room
Outdoor unit
Outdoor unit

Indoor unit

Indoor unit
Opening
Partition

51

In the case of opening


without door , or 0.15
% or more openings
(to floor space) both
above and below door)

Installation

(3) With partition and without opening which serve as passage of air to adjoining room
Outdoor unit

Indoor unit
Smallest
room

Calculate refrigerant concentration


Total amount of replenished
refrigerant in refrigerant facility (kg)

= Refrigerant concentration

Capacity of smallest room where


indoor unit is installed (m3)

(kg/m )
(R410A)

In case the concentration exceeds the limit

In case the result of calculation exceeds


the limiting concentration, perform the
same calculations by shifting to the
second smallest, and the third smallest
rooms until at last the result is below the
limiting concentration.

When the concentration exceeds the limit, change original plan or take one of the countermeasures
shown below:
Countermeasure 1
Provide opening for ventilation.
Provide 0.15% or more opening to floor space both above and below door, or provide opening without door.
Countermeasure 2
Provide gas leak alarm linked with mechanical ventilator.
Reducing the outdoor refrigerant qty.
Gas leak alarm
Countermeasure 2
Mechanical ventilator

Indoor unit

Countermeasure 1 Opening effective to ventilation

Pay a special attention to the place, such as a basement, etc. where refrigerant can stay, since refrigerant is
heavier than air.

Installation

52

P/No.: 3828A20892J

Air Conditioner
20 Yeouido-dong, Yeongdeungpo-gu,
Yeouido P.O.Box 335 Seoul,
150-721, Korea.
http://www.lgeaircon.com

All rights reserved


Printed in Korea April/2008
The specifications, designs, and
information in this brochure are subject to
change without notice.

File No. : A8974


Volume:1

Certificate No. :
E00626/1

The air conditioners manufactured by LG


have received ISO9001 certificate for
quality assurance and ISO14001
certificate for environmental
management system.

You might also like