You are on page 1of 12

Orange CI

RF ANALYSIS AND OPTIMIZATION REPORT

ABIDJAN Cocody Cluster1


Huawei RF team

16th March 2015.


All rights reserved

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

Contents
INTRODUCTION
3
1FINDINGS AND RECOMMENDATIONS:
1.1
TEST ROUTE OVERVIEW:
3
1.2
MS RSCP PLOT:
3
1.3
MS EC/NO PLOT
4
1.4
MS DL INTERFERENCE PLOT: 4
1.5
MS PSC PLOT:
5
1.6
DT KPI SUMMARY
5
1.7
BAD PATCHES 5
1.8
ACTION SUMMARY
10
1.9
CONCLUSION 11

I)

VOICE SERVICE TEST


Introduction
Page 2 of 12

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

The drive test route covers Cocody cluster1 and was driven the 05th March 2015.

1-Findings and Recommendations:


1.1

Test Route Overview:

1.2

MS RSCP Plot:

1.3

MS Ec/No Plot

Page 3 of 12

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

1.4

MS DL interference plot:

1.5

MS PSC Plot:
Page 4 of 12

Orange CI Drive Test Report

1.6

Division:

Abidjan Cocody

Test Route:

Cocody

DT KPI Summary

KPI (2G)
Outgoing Call Setup Success Rate
(CSSR)
Call Drop Rate (CDR)
Handover Success Rate (HOSR)
RSCP (dbm) >= -95dbm and
EcIo>= -12

1.7

Sho
rt
Call
97.0
1
1.53
100
68.6
6

BAD PATCHES

A) BAD PATCHE 1

Events: Bad patch (Poor Coverage)


Causes: PERLES Sector2 overshooting
Recommendations: Adjust PERLES sector2 tilt from 5 to 8
Page 5 of 12

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

B) BAD PATCHE 2

Events: Bad patch (Poor Coverage)


Causes: MEECI Sector3 overshooting
Recommendations: Adjust MEECI sector3 tilt from 6 to 8
C) BAD PATCHE 3

Events: Bad patch (Poor Quality)


Page 6 of 12

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

Causes: Pilot Pollution


Recommendations: Set electrical tilt of NOTRE_DAME_NEW_2200-1 from 7 to 9,
BIAFRA_2200-3 from 10 to 12, CATHEDRALE_2200-1 from 8 to 11 and GRATRY_2200-1
mechanical tilt should be set to 8 instead of 6. OITH sector 2 mechanical tilt should be set to 2
D) BAD PATCHE 4

Events: Bad patch (Poor quality)


Causes: Overshooting, pilot pollution
Recommendations: Adjust the antennas tilt of LYCEE_TECHNIQUE_2200-2 should be set to 9
instead of 7, PISAM_2200-1 & 3 to 15, INDENIE_2200-11 mechanical tilt should be set to 2
E) BAD PATCHE 5

Events: Bad patch (Poor quality)


Causes: Overshooting and pilot pollution
Recommendations: Check ANDOKOI PSC reutilization if it is not re-use, we should downtilt
ANDOKOI_MARCHE_2200-1 from 4 to 8, RESERVE_2200-1 mechanical tilt from 0 to 2.

F) BAD PATCHE 6
Page 7 of 12

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

Events: Bad patch (Bad quality)


Causes: Downlink Interference
Recommendations: Check the traffic load of those cells. RITCH_2200-3&2 downtilt from 7,8 to 10
G) BAD PATCHE 7

Events: Bad patch (Bad quality)


Causes: Pilot pollution
Recommendations: Add Riviera_2200-12 and RITCH_2200-22 to RITCH_2200-32
Downtilt SODEFOR_2200-2 from 4 to 8, MSC_2200-2 from 6 to 9 and INSAAC_2200-1 from 5 to
8

H) BAD PATCHE 8
Page 8 of 12

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

Events: Bad patch (Bad quality)


Causes: Pilot pollution
Recommendations: Reduce the pilot power of CORNICHE_PALMIER_2200-1 and IPNEPT_2200-3
by 2dB, ARCHEVECHE_2200-3 downtilt should be set at 10 instead of 9.
I) BAD PATCHE 9

Events: Bad patch (Bad quality)


Causes: Downlink interference
Recommendations: The traffic on BIA_ND should be check and reduce.

1.8

Action Summary
Page 9 of 12

Orange CI Drive Test Report

ACTIO
N
POINT

PERLES

MEECI

Abidjan Cocody

Test Route:

Cocody

SITE NAME

Division:

Action

Adjust PERLES sector2 tilt from 5 to 8

CHARDY

Adjust MEECI sector3 tilt from 6 to 8


Set electrical tilt of NOTRE_DAME_NEW_2200-1
from 7 to 9, BIAFRA_2200-3 from 10 to 12,
CATHEDRALE_2200-1 from 8 to 11 and
GRATRY_2200-1 mechanical tilt should be set to 8
instead of 6. OITH sector 2 mechanical tilt should be
set to 2

ANAULICE

Adjust the antennas tilt of


LYCEE_TECHNIQUE_2200-2 should be set to 9
instead of 7, PISAM_2200-1 & 3 to 15,
INDENIE_2200-11 mechanical tilt should be set to 2

ANDOKOI_MARCHE and
BIA_ND

Check ANDOKOI PSC reutilization if it is not re-use,


we should downtilt ANDOKOI_MARCHE_2200-1
from 4 to 8, RESERVE_2200-1 mechanical tilt from 0
to 2.

Check the traffic load of those cells. RITCH_2200-3&2


downtilt from 7,8 to 10
CAMPUS
Add Riviera_2200-12 and RITCH_2200-22 to
RITCH_2200-32
Downtilt SODEFOR_2200-2 from 4 to 8, MSC_22002 from 6 to 9 and INSAAC_2200-1 from 5 to 8
RITCH

ANAULICE

Reduce the pilot power of


CORNICHE_PALMIER_2200-1 and IPNEPT_2200-3
by 2dB, ARCHEVECHE_2200-3 downtilt should be set
at 10 instead of 9.

BIA_ND

The traffic on BIA_ND should be check and reduce

Owner

Huawei
with
Orange
permissio
n
Huawei
with
Orange
permissio
n
Huawei
with
Orange
permissio
n
Huawei
with
Orange
permissio
n
Huawei
with
Orange
permissio
n
Huawei
with
Orange
permissio
n
Huawei
with
Orange
permissio
n
Huawei
with
Orange
permissio
n
Huawei
with
Orange
permissio
n

Tim
e
Lin
e

Statu
s

Open

Open

Open

Open

Open

Open

Open

Open

Open

Page 10 of 12

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

Existing physical parameter


Mech
Elect
Azimuth
Downtilt
Downtilt
Power

CELLS

Azimuth

New physical parameter


Mech
Elect
Downtilt
Downtilt

PERLES _2200-2

MEECI _2200-3
NOTRE_DAME_NEW_220
0-1

BIAFRA_2200-3

10

12

CATHEDRALE_2200-1

11

GRATRY_2200-1

OITH _2200-2
LYCEE_TECHNIQUE_220
0-2

PISAM_2200-1
PISAM_2200-3

14

15

14

INDENIE_2200-1
ANDOKOI_MARCHE_220
0-1

RESERVE_2200-1

15
2

8
2

RITCH_2200-3

10

RITCH_2200-2

10

SODEFOR_2200-2

MSC_2200-2

INSAAC_2200-1
CORNICHE_PALMIER_22
00-1

8
Reduce
2dB
Reduce
2dB

IPNEPT_2200-3
ARCHEVECHE_2200-3

1.9

Power

10

Conclusion

The 3G network coverage is acceptable but the quality need to be improve by


controlling the downlink interfence through implemention of the above
recommendations. Another test will be perform after modification to confirm the
result.

Page 11 of 12

Orange CI Drive Test Report


Division:

Abidjan Cocody

Test Route:

Cocody

RTWP ANALYSIS

The above above analysis shows a constant and high RTWP value on SUP_MANAG_1
which is an evidence of steady interference on the sector which could be as result of
external interference.
Frequency scanning is recommended around this site for external interference check or
cable sweeping to be done to check for high VSWR value with the help of site master.