You are on page 1of 12

Optix RTN 900 Radio Transmission System

Optix RTN 900 Radio Transmission System


Microwave ATP Functionality Test
Microwave Scope of Work:
New Link
Swap Link

Upgrade Link Capacity by Change Frequency


Upgrade Link Capacity by Software
Upgrade Link Capacity by Software and Hardware

Customer / Project Name


Near End Site ID Name
Far End Site ID Name
Transmission Configuration

:
:
:
:

INDOSAT/ PDH MW MBS Makassar


RTN900/7G/1+1/1.2SD/157M

________________________________________

Optix RTN 900 Radio Transmission System

On this date _____________________, we the undersigned hereby certify that the


Optix RTN 900 Radio Transmission System equipment at the above location is
installed, tested and accepted according to the attached Technical Test Protocol.

On behalf of PT. HUAWEI TECH INVESTMENT:

Signed:
Name:

Position:

On behalf of PT. INDOSAT:

Signed:
Name:

Position:

C O N T E N T:
1. Configuration Check
2. Receive Power Level Result
3. SDH Service Configuration
4. Ethernet Interface
5. Ethernet Service Configuration
6. Browse Alarm Check
7. NE Visibility on NMS System
8. Document Attachment

Optix RTN 900 Radio Transmission System

Optix RTN 900 Radio Transmission System

REVISION HISTORY
Date

Revision

2014/ Apr/10

V1.0

Toni Riyanto

2014/ Apr/15

V1.1

Toni Riyanto

1)

Description

Authors

Configuration Check

Near-End Site Set-Up


Frequency Plan (MHz)
Transmitted frequency (MHz)
Received frequency (MHz)
ODU Sub Band
Tx power requested (dBm)

Channel 1

Channel 2 (*)

Channel 3 (*)

Channel 4 (*)

Channel 1

Channel 2 (*)

Channel 3 (*)

Channel 4 (*)

Modulation
E1 Capacity
Ethernet Capacity (Mbps)
(*) if Applicable
Far-End Site Set-Up

Optix RTN 900 Radio Transmission System


Frequency Plan (MHz)
Transmitted frequency (MHz)
Received frequency (MHz)
ODU Sub Band
Tx power requested (dBm)
Modulation
E1 Capacity
Ethernet Capacity (Mbps)
(*) if Applicable

2)

Receive Power Level Result


ODU 1
Item

Near-End Site
ODU 2
ODU 3
(*)
(*)

ODU 4
(*)

ODU 1

Far-End Site
ODU 2
ODU 3
(*)
(*)

Rx level in link budget (dBm)


Rx Level (dBm)
Tx Power (dBm)
(*) if Applicable

3)

SDH Service Configuration


Item

Near-End Site

Far-End Site

Near-End Site
Enable
Disable

Far-End Site
Enable
Disable

E1 Capacity

4)

Ethernet Interface
Port

Port 1
Port 2
Port 3
Port 4
Port 5
Port 6

5)

Ethernet Service Configuration

VLAN Configuration
2G VLAN data
3G VLAN data
2G/3G VLAN OAM
MW OAM

6)

Near-End Site

Far-End Site

Browse Alarm Check


Check Item

Near-End Site

Far-End Site

ODU 4
(*)

Optix RTN 900 Radio Transmission System

Current Alarm

OK NOK

OK NOK

History Alarm within 24hours

OK NOK

OK NOK

Normally the related NE should be no alarm, the alarm is affected from activity or not, case by case, please
FM escalate to MS BO for more query.

7)

NE Visibility on NMS System

Site
NE Visibility on NMS System
Near-End Site
OK NOK (*)
Far-End Site
OK NOK (*)
(*) Screenshot from NMS system should available as attachment

Optix RTN 900 Radio Transmission System


8) Document Attachment
Configuration Check
Bonto_Kamase

Receive Power Level Result


Bonto_Kamase

Interference Check
Bonto_Kamase

Optix RTN 900 Radio Transmission System

Browse Alarm Check


Bonto_Kamase

NE Visibility on NMS System


Bonto_Kamase

Optix RTN 900 Radio Transmission System

Configuration Check
Sunggumnasa

Receive Power Level Result


Sunggumnasa

Optix RTN 900 Radio Transmission System

Interference Check
Sunggumnasa

Browse Alarm Check


Sungguminasa

Optix RTN 900 Radio Transmission System

NE Visibility on NMS System


Sungguminasa

Punch list RTN 900 ATP


Link ID

Link Name

Optix RTN 900 Radio Transmission System

PT. Huawei Tech Investment


Representative

Name: -------------------------------------------

Cosmetic

Minor

Description

Major

Item No.

Severity
Date to
be
cleared

Date
Responsible Cleared**
Group*

Supervisor

PT. Indosat
Representative

-----------------------------------------------------

Date: