PCBVac-Dry, wet or hot vacuum tool for PCB rework

Users Guide

www.solder.net BEST Inc (847)797-9250


3603 Edison Place Rolling Meadows IL 60008 info@solder.net
BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 1

Table of Contents

Page

Description

Title Page

Table of Contents

Introduction

Safety

Specifications

Features and Controls

7-9

Getting Started

10

Replacement Parts

11

Troubleshooting Guide

12

Warranty

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 2

Introduction
You have selected a high quality, highly reliable BEST PCBVac system. This system is
designed specifically for picking up the remnants from the PCB rework and repair
processes including cleaning out solder from plated throughholes, cleaning off scraped
solder mask or coating or remnant flux of cleaning solvents. In addition, liquids such as
cleaning solvents and fluxes can be vacuumed off the PCB.
This users guide will help you maximize the he usefulness of the PCBVac.
Please take a few minutes to become familiar with the controls and features of the
device. Follow our recommended testing procedures. Review the helpful information we
have included which is based on a combined 150+ years of PCB rework and repair
experience.
In the USA please call us at 847-797-9250 between 7:30AM-5:30 PM CST or visit
solder.net to send us an e-mail.

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 3

Safety
Maximum Air Pressure
Maximum air input pressure 6.9bar (100psi). Excessive input air pressure may damage
the equipment

Read Manual
Read the Userss Guide for proper use of this equipment. Follow all safety instructions.
Task and equipment specific warnings, cautions and instructions are included in the
equipment documentation when appropriate. Make sure these instructions and all other
equipment documents are accessible to persons operating or servicing the equipment.

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 4

Specifications
Cabinet dimensions:

4 L X 3 W X 2D ( 101.6 x 76.2 x 50.8 mm)

Weight:

0.65lbs (1.0 kG)

Cycle initiate:

ON/OFF Switch

Air input requirements:

7 bar (100psi) maximum

Vaccum output

0-110 inches H2O dependent on user potentiometer setting

Ambient Operating Conditions


Temperature:
Humidity:

C to 45 C (41F to 113F)
85% RH at 30C non-condensing

RoHS, WEEE Compliance: Yes


Product Class

Installation category II
Pollution degree 2

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 5

Features and Controls


Vacuum air regulator adjustment knob-control vacuum level. Clockwise rotation creates
more negative pressure
On/Off switch turns air to unit on and off
Output Quick Connector-vacuum pick up wand with removable Teflon tip
Air input push-in fitting main filtered air supply via 1/4FNPT
Vacuum Exhaust Port-vacuum air exit

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 6

Getting Started
1) Unpack Unit
2) Connect Air Supply

3) Attach and configure the nozzle

4) Attach and configure nozzle

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 7

5) Attach the glass handpiece

6) Turn on pneumatic switch

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 8

7)

Adjust vacuum until desired affect is reached

Begin moving hand piece to areas on PCB to remove wet and dry particles.

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 9

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 10

Replacement Parts
Item#

Part #

Part Description

PCBV-CP

Quick Disconnect Coupler Plug FNPT, Body

PCBV-QCA

Quick Connect x plastic compression adaptor

PCBV-PVCT

x 0.170 PE Tubing hose, ft

PCBV-TN

Teflon nozzle

PCBV-FSF

Front silicone fitting

PCBV-GT

6 glass handpiece

PCBV-MT

Metal trap

PCBV-FE

Filter element

PCBV-RSF

Rear silicone fitting

10

PCBV-BGSA

Brass gap suction adaptor

11

PCBV-PT

12

PCBV-IAF

ft, x 1/8 PVC tubing


In-line control air filter, 25 microns

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 11

Troubleshooting Guide
If there is little or no vacuum pressure are the work piece check the following:
1.
2.
3.
4.

Make sure the input air source is on and is between 40-100psi


Make sure the PCBVac ON/OFF switch is turned to the ON position
Make sure the vacuum ouput control knob is turned CW(+)
Make sure the Teflon nozzle is free and clear of debris. Clean the tip out with a
small dental tool or paper clip
5. Make sure the air lines are no kinked and they are not pinched off
6. Mae sure the metal trap and filter element are clear

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 12

Warranty
This BEST PCBVac is warranted to the original end user for one year from date of
purchase. Within the period of this warranty BEST will repair or replace and defective
component r the entire assembly at BESTs option on authorized return of the part or
the complete vacuum system, prepaid to the factory.
In no event shall any liability or obligation of BEST arising from this warranty exceed
the purchase price of the equipment. Before using , user shall determine the suitability
of the product for its intended use assumes all risk and liability whatsoever in the
connection therewith.
BEST makes no warranty whatsoever of merchantability of fitness for a particular
purpose. In no event shall BEST be liable for incidental or consequential damages.

To register your warranty in the USA, please send an email to info@solder.net.

BEST PCBVac Users Guide Revision 0.1

December 30, 2013

Page 13

You might also like