You are on page 1of 2

UNREGULATED POWER SUPPLIES

INSTALLATION AND OPERATION


GOLD BOX MODELS: Threaded holes on the bottom and one side surface (no side mounting holes on case size YH11) may be
used for mounting. The supply may also be rear mounted (except for case size YA) using the same holes that attach the rear cover
plate. An accessory Mounting Kit (model GB8) is available to enable mounting the power supply when the opposite side of the
mounting surface is inaccessible.
PLUG-IN MODELS: Plugs into standard 8-pin octal socket (order accessory socket SL608). Four 6-32 mounting holes (on case
sizes G and K) or four 10-32 mounting studs (on case sizes Q and P) are provided in the base for fastening the module when
used in other than the upright position, or if extreme vibration will be encountered.

Even a relatively small amount of air flowing around and through a power supply will significantly reduce the rise in its temperature
resulting from operation, and therefore the temperature of the critical components within it, improving both reliability and stability.
Avoid blocking air flow through vented/perforated surfaces. If the perforated bottom of a supply is mounted to a solid surface, use
spacers at least 3/16 thick between it and the surface to which it is fastened, to permit convection air flow, or punch ventilation
holes in the mounting surface. Allow free air to circulate around heat sinks. Space at least one inch away from surrounding objects.
Make all connections before applying AC input power.
Two or more of the same model may be connected in parallel.
Two or more of the same or different models may be connected in series to obtain a higher voltage up to 1000 Vdc, provided that
a reverse-biased diode is used across each output; however, the output current to be drawn cannot exceed the output current
rating of the lowest rated supply used.
Frequent fuse failure is symptomatic of power supply overload, a short circuited output, or power supply failure. Do not overfuse;
this can result in damage to the power supply.
If the AC input power contains large voltage spikes (noise) induced by the switching of high currents, inductive loads, electromechanical components, etc., the input power leads to the supply should include some means of transient suppression.
Otherwise, a portion of the noise may be coupled through the supply to the load. Also, the supply could be damaged. The means
of suppression that is easiest to install is a 1 mfd. capacitor or a metal oxide surge suppressor (MOV) across the AC input
terminals of the supply. In extremely severe cases, the use of RF chokes in series with each side of the line may also be required.

N
COPIA
ALL A
LIES
SUPP
R
E
.A.
POW
IN U.S
E
D
A
M
WARRANTY: Acopian power supplies are warranted to be free from defects in material and workmanship
for a period of five years (encapsulated devices and fans, for one year) from date of original shipment.
Acopians obligation under this warranty is limited to repairing any power supply returned to the factory
Service Department in Easton, PA and replacing any defective parts. Authorization must be obtained from
Acopian before a power supply may be returned for repair. Transportation charges are to be paid by the
purchaser. A reinspection and handling charge will be applied to returned units found to have no defects.
If a failure has been caused by misuse, operation in excess of specifications, or modification by the
customer, repairs will be billed at cost; in such cases, a cost estimate will be submitted before work is
started.
Acopian reserves the right to make changes or improvements in its products without incurring any
obligation to install the same on products previously manufactured.
This warranty is in lieu of all other warranties, obligations, and liabilities, expressed or implied, and is
the purchasers exclusive remedy. Acopian makes no warranty, either express or implied, of merchantability,
fitness for a particular purpose or otherwise. In no event shall Acopian be liable for incidental or
consequential damages of any kind, including loss of business or profits, or any other losses incurred by
the purchaser or any third party.
The validity, performance and construction of all terms and conditions and any sale made by Acopian
shall be determined by the law of Pennsylvania, not including its law of conflict of laws.

The complete Acopian catalog is available on the Internet at http://www.acopian.com

P.O. Box 638, Easton, PA 18044 Phone: (610) 258-5441 FAX: (610) 258-2842

UNREGULATED POWER SUPPLIES


L

AC INPUT

F1

*
*

0-125 VAC, 115 VAC nominal , 50-400Hz


(Standard)
0-250 VAC, 230 VAC nominal , 50-400Hz
(When model number ends in -230)

**

T2
(Not used on

Output voltage proportionate to input voltage.

all models)

K2

T1

C1

K3

DC
OUTPUT

R1

OUT

Dotted line connection required


** when
K1 and K2 are omitted.

CASE

+OUT

K4

K1

Numbers correspond to
plug pins on Plug-in models.

The MODEL NUMBER indicates any included options;


suffix F: fungus proofing
suffix M: terminal strip cover
suffix 230: 230v input

GOLD BOX MODELS:

Barrier Strip for YH11


(with 8 -32 terminal screws)

.78

FUSE

For REAR MOUNTING, remove original screws(4) and use


8-32 Type F self-tapping screws. They should extend
at least 5/16 (0.312) into the power supply case.
(Case size YA is not rear mountable.)
L

Y3
3.71
Y5
5.09
Y6
6.59
YH11 11.25
YA
6.59

5.12
5.12
5.12
7.37
5.12

3.44
3.44
3.44
5.12
3.44

1.62
3.0
4.0
8.0
4.0

4.5
4.5
4.5
6.75
4.5

3.0
.56
3.0
.56
3.0
.56
4.56 1.10
3.0
.56

1.37 .75
1.37 .75
1.37 .75
2.64 1.25
1.37 .75

D
1.44
1.44
1.44
2.25
1.44

.075

Y
Adjustment
(case size YA only).
Increases length by .925.

Case
Size

SIDE MOUNTING

8-32 threaded
holes(4) (none for
case size YH11).
Maximum incursion of
screws into mounting
holes: 5/16 (.312)

LM

FUSE

1.0

BOTTOM MOUNTING
8-32 threaded holes(4).
Maximum incursion of
screws into mounting
holes: 5/16 (.312)

Standard 8-Pin
Octal Plug

Output Adjustment
(case size P only)

C (Typ.)

PLUG-IN MODELS:
REV2

FUSE
L N
AC AC

Barrier Strip for Y3, Y5,Y6, and YA


(with 6-32 terminal screws)

L N
AC AC

NAME
PLATE

OUT

OUT

FUSE

OUT

Approx.
Weight

.375 2 lb.
.375 4 lb.
.375 7 lb.
.562 18 to
.375
4 to

8 oz.
8 oz.
8 oz.
23 lb.
5 lb.

Case
Size

3.40

3.28

5.12

2.625

2.625

Four 6-32 x .25


deep mounting holes

2 lb. 8 oz.

4.15

3.33

5.44

2.750

2.562

Four 6-32 x .25


deep mounting holes

4 lb. 4 oz.

2.562

Four 10-32 x 9 16

Q
P

4.15
4.15

3.33
3.33

7.12
7.25

2.750
2.750

2.562

Approx.
Weight

long mounting studs

7 lb.

Four 10-32 x 9/16


long mounting studs

5 lb.

The complete Acopian catalog is available on the Internet at http://www.acopian.com

P.O. Box 638, Easton, PA 18044 Phone: (610) 258-5441 FAX: (610) 258-2842