You are on page 1of 6

Technical Specifications For Femtocell Access Point

Radio Frequency Equipment

Technical Specifications for the Third Generation Mobile Telecommunication


Femtocell Access Point Radio Frequency Equipment
1. Scope
This regulation applies to the type approval of the third generation mobile
telecommunication Femtocell access point radio frequency equipment, which is
WCDMA FDD stated in IMT-2000.
2. Technical Standard
2.1

This regulation is stipulated based on European Unions ETSI EN 301908-3,


the 3rd Generation Partnership Project 3GPP TS25.104, TS25.141, the R.O.C.
national standards (CNS14959, CNS13438 and CNS14336) and other

2.2

international technical standards.


Under the consideration of having the nations third generation mobile
telecommunication Femtocell access point radio frequency equipment
consistent with international technical standards, all the testing items,
eligibility Criteria and testing methods stated in this regulation will follow the
up-to-date version of technical standards.

3. Test Items and Specification Value


Details regarding the testing items and specification values of the mobile
telecommunication Femtocell access point are described in attachment 1.
4. Testing Requirements
4.1 For testing item 1, it is a must to select two channels one with the highest
frequency and one with the lowest frequency for the measurement.
4.2 All the testing procedures shall follow relevant rules stated in 3GPP TS25.141;
for testing items 2, 3, 4, 5, 6, 7 and 8, at least three channels from the low /
medium / high frequency shall be selected for the measurement.
4.3 For testing item 9, one must choose a channel from the medium frequency for
measurement.
5. Descriptions of the Type Approval
This type approval is only for testing items. It does not make guarantees for
equipments overall function nor other inspection items. Besides, in terms of
installation and usage, it is a must for equipments received the type approval
certificate of this technical specification to follow the Telecommunications Act.
2

Attachment 1

Testing Items and Specification Values for the Third Generation Mobile
Telecommunication Femtocell Access Point (WCDMA FDD) Radio Frequency
Equipment
Ite
ms

Testing Items

Frequency Bands

Specification Value
Receiver bandwidth from 1920 to 1980MHz; transmitter
bandwidth from 2110 to 2170 MHz

Maximum Output
Power

Frequency error

With test
report
With test
report

2 Occupied Bandwidth 5MHz

Remarks

With test
Under the normal condition:
report
The rated maximum output power is 20dBM, where the
tolerance range of the measurement value and suppliers rated
value is within 2.7dB.
With test
0.25ppm
report

Spectrum emission The specification value of the spectrum emission mask is shown With test
report
mask
as the attached table 1.

Adjacent Channel
Leakage Ratio
(ACLR)

Base station (BS) adjacent channel offset: 5 MHz


Adjacent channel leakage ratio (ACLR) limit: 44.2dB
Base station (BS) adjacent channel offset: 10 MHz
Adjacent channel leakage ratio (ACLR) limit: 49.2 dB

Spurious Emissions Shall be in compliance with the specification value as shown in


attached table 2.
Transmit
intermodulation

With test
report

With test
report

The carrier level for transmitting intermodulation shall not With test
report
exceed the specification value of radiated spurious emission
(RSE) (for modulated interference signal lower than the main
signal at 30dB carrier level, its frequency differed from the
main
signal
can
only
differ
within
5MHz10MHz15MHz). Any interference outside the
transmitter bandwidth within 2110 to 2170 MHz is not under
the consideration.

Home BS output According to the configuration listed in attached table 3-1, the With test
report
power for adjacent specification value must be in compliance with the specification
channel protection value in attached table 3-2, whereas the maximum output power
shall be listed within the specification value 2.7dB listed in
attached table 3-2.

(This test item was officially carried out on November 30,


2011)
Maximum
Shall be in compliance with regulations stated in CNS14959 for With test
report and
Permissible Exposure the time varying electric field and reference level of public
antenna
(MPE)
exposure. That is, 20 cms away from the transmission source
specificati
on data
with power density specified at 1.0mW/cm2.
With test
11 Electromagnetic Shall be in compliance with the Class B (Yi) technical
report
Compatibility
equipment specifications stated in CNS13438.
(EMC)
12 Electrical Safety Shall be in compliance with specifications stated in CNS14336. With test
report
(Safety)
10

Attached Table 1

Specification Value of Spectrum Emission Mask


Base

Frequency offset of

Frequency offset of measurement

station

measurement filter-

filter centre frequency, f_offset

(BS)

3dB point, f

Maximum level

Measurement
bandwidth

maximum
output
power, P
P 20

2.5 f < 2.7 MHz

2.515 MHz f_offset < 2.715 MHz

-20.5 dBm

30 kHz

dBm

2.7 f < 3.5 MHz

2.715 MHz f_offset < 3.515 MHz

-20.5 -15( f_offset - 2.715) dBm

30 kHz

3.515 MHz f_offset < 4.0 MHz

-32.5 dBm

30 kHz

3.5 f < 7.5 MHz

4.0 MHz f_offset < 8.0 MHz

-19.5 dBm

1 MHz

7.5 f 12.5 MHz

8.0MHz f_offset <13 MHz

-23.5 dBm

1 MHz

Specification Value of Extra Spectrum Emission Mask

6P20

12.5 ffmax MHz

13MHz f_offset < f_offsetmax

P 54.5dBm

1 MHz

12.5 f fmax MHz

13MHz f_offset < f_offsetmax

-48.5 dBm

1 MHz

dBm
P<6 dBm

Remarks:
f_offsetmax: Between 12.5 MHz and the center carrier frequency from 2110 to 2170 MHz, the one that
has a bigger frequency deviation.
fmax: f_offsetmax half amount of the measurement bandwidth.
Attached Table 2

Regulations of the Spurious Emissions


Band

Maximum level

Measurement Bandwidth

9kHz 150kHz

- 36 dBm

1 kHz

150kHz 30MHz

- 36 dBm

10 kHz

30MHz 1GHz

-36 dBm

100 kHz

1GHz Fc112.5 MHz

-30 dBm

1 MHz

Fc112.5 MHz Fc2+12.5 MHz

-15 dBm

1 MHz

Fc2+12.5 MHz 12.75 GHz

-30 dBm

1 MHz

Remarks

Remarks:
Fc1: the first transmitted center carrier frequency.
Fc2: the last transmitted center carrier frequency.
Attached Table 3-1

Test Parameters of the Home BS Output Power for Adjacent Channel Protection
Testing
Environment

c (dBm)
CPICH E

Ioh (dBm)

-80

-50

-90

-60

-100

-70

-100

-50

Attached Table 3-2

Specification Value of the Home BS Output Power for Adjacent Channel Protection

Input Conditions

Output Power

c +43dB
Ioh > CPICH E
c -105dBm
and CPICH E

+10dBm

c +43dB
Ioh CPICH E
c -105dBm
and CPICH E

c +100dB))
max(8 dBm, min(20dBm, CPICH E

Remarks:
c : the code power of adjacent channels common pilot channel.
CPICH E
Ioh: received power density including the signal and interferences; however, the signal of the object to
be measured is excluded.